8950 SW PINEBROOK STREET-1 ADDRESS: i:'uecords\micrutlm'Aargets\building.doc v/ i 9 y X�y Uea P -.-' -'PELLET ST� VE 9M. a r r INSERT PREI��ATIdN'. -INSTALLAI. N, OPERATION AND. M�INT8NA E ' 'MANUAL i sem, - • - -_ .z, U � KEEP THIS MANUAL August, 1991 Manufactured By: TiravH c Wies ,Inc. 108. 0 117th Place ME.. Kirkland, WA 98033 °-COpyright 1991 T.I. READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW APPLIANCE. FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN 13ROPERTY DAMAGE,BODILY INJURY,OR EVEN DEATH '1 . PREPARATION: I. Remove all tape and packaging. 2. Remove the wood shipping frame from around and under the appliance. 3. Check that no parts have become loose and the appliance has not been damaged dur!ng shipping. 4. Remove the hardware pack from the appliance. b. READ THM OWNER'S MANUAL BEFORE PROCEEDING. * Appliance should be located such that no doors, drapes,furniture or other combustibles can be placed close or swing closer than the minimum stated clearances. ' The appliance must be installed in a level, secure position. * Required Floor Protection: Minimum size 24'W x 33"D (610mm W x 838 mrr.D) Front- 6` (152 mm) of nun-combustible mb.1wial Kofi a rrinimu,n thickness Sides C" ( c mm) of 26 gauge(.018", .5mm) floor protection must extend Back - 0" ( 0 mm) under tho appliance. C;hlmney Lengths `Mxxlmum Minimum Vertical 33' (10.06 m) Subject to installation. See Fig. 9 Horizontal 10' (3.05 m) I,ubject to installation. See Fig. 4&9 * Do not obtain comp-ustion air from attic,garage, unventilatec'crawl space or any other enclosed space. Do not locate combustion air inlet at an elevation higher than exhaust termination, C ; ' Outside air(combustion air intake) is recommended,but not required, for all residential installations, but is required for mobile home installations. If an outside air intake(combustion air intake) is useo, it must be connected to a 1-3/4", or larger, metal or aluminium duct with a rodent screen fixed to the termination. Do not use p,v.r..duct. NOTE: TRAVIS INDUSTRIES, INC., recommends that an outside air(combustion air) intake bp used in all installation, If one is not used, there is a possibility of combustion gasas (smoke) being relem., i into your home, If there is a power outage while the unit is in operation. * The AVALON 800 pellot stove exhaust vent accepts 3"diameter pellet vent pipe. Some of the brands available for use with the AVALON v00 are.- 1. Duravent Model PL-Vent 2. James A Ryder MFG Mode;PI_-Vert 3. MetalFah Model Pellet Vent Simpson Dura-Vent Hyder Mfg., Inc P.O. Box 1138 P.O. Box 1510 241 Arvin Avenue Wichita, KS 67201 Vacaville, CA 95688 Stoney Creek, Ontario Canada (707) 446-1786 or (416) 662-1701 (316) 943-2351 1-800-227-8846 NOTE: 4'diameter mny be substituted when a 3"to 4"adapter is used. See manufacturer's installation instiuctions for precautions required for passing vent through a combustible wall or ceiling. Do not connect this appliance to a vent serving anc`her appliance. All sections of pellet vent must be fastened to each other with sheet metal screwy and silicone sealed with type 500 degrees Fahrenheit (260°C) RTV(high heat)silicone sealer,to 9nsure that the joints are airtight. 'AGE 5