TUALATIN VALLEY FIRE & RESCUE
AND
BEAVERTON FIRE DEPARTMENT"
4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverlon, OR 97076 • (503) 526-2469• FAX 526-2538
April 2 , 1990
Terry Cone
P.O. Box 271
Lake Oswego, Oregon 97034
Re: 11654 S.W. Pacific Highway
Tigard, Oregon
Dear Mr. Cone:
This is a Fire and Life Safety Plan Review and is based on the 1.988
editions of the Fire and Life Safety Cole (UBC) , Mechanical. Fire
and Life Safety Cour (UMC) , Uniform Fire Code (UFC) , and other
local ordinances and regulations .
Plans are conditionally approved subject to the following items:
1 . Eaves : Where eaves are located within location of
property lines where window protection is required, eaves
shall be not less than one hour fire resistive
construction. This Plans Examiner would suggest cutting
off the eave line adjacent the exterior wall, located
parallel_ to the property line, and placing a gutter along
the wall .
2 . Address Required: The tenant space number must be
prominently displayed on the street front where it is
readily visible to drivers and officers of responding
fire apparatus and other emergency vehicles . UFC Sec .
10 . 208
3 . Fire Extinguisher- Regui ed_ A fire extinguisher having
a minimum rating of 2Al0a:C must be placed in an
accessible location within plain view. UFC Sec .
10 . 301(a)
4 . Firestoppi.ng: In all wood framed walls and partitions,
firestopping conoisting of 2-inch nominally-sized lumber
or other approved materials must be installed at all
floor and ceiling levels . Penetrations in this
prescribed fir-estopping to accommodate wiring, plumbing,
"Working"Smoke Detectors Save Lives
WWLW11W
Terry Cone
April 2 , 1990
PLge 2
and other similar utility .runs must be packed with
noncomLustibl.e materials in an approved manner so as to
prevent the passage of flame. UBC Sec . 2516
5 . Exterior Exit Door: Hardwart ! or the extE:rior doors and
key operated deadlocks may be permitted where there is
a sign posted on or over the door reading, "THIS DOOR
MUST REMAIN UNLOCKED DURING BUSINESS HOURS" in letters
not less than one-inch :i.n height on a contrasting
background. UBC Ser. . 3304
6 . APP-1--oved Plans on Job Site: One set of approved plans
bearing the stamps of the building department issuing the
construction permit and this office must be maintained
on the project site throughout all phasc!s of construction
and must be made avail.abL? to br..ilding and fire
inspectors for reference duri:19 reraired construction
inspections . UBC Sec . 303
7 . Required C` �-__,Ap Certificate: Prior to the use and
occupancy of the project (space) , a certificate of
occupancy or other written instrument of approval must
be obtained from the building department issuing the
coY. 3tr_uction permit. UBC Sec . 307
If I can be of any further assistance to you, please feel free to
contact me at 526-2502 .
Sincerely,
Gene Birchill
Deputy Fire Marshal
GB:kw
cc: Tigard Building Department
.. ,..•r.-.q•+N*R'wpow"ImeAl�'Mwn-,r„wr.:
CITY OF
TIC ARS 6-2 , » °5N° 0310
BUILDING PERMIT APPLICATION °ATE
1HE UNDERSIGNED HEREBY APPLIES FOR APERMIT FOR THE WORK HEREIN INDICATED OWNER PHONE_
OR AS SHOWN AND AFPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS,
H.C. PippLnIlLb4 :,.W. Pmlcific: Hw'UILDERPHONE
OWNER ADDRESS
ENGINEER
HW LJ2(<El_
_ ARCHITECT DESIGNER
STRUCTURE _❑NEW_ _-�LJREMODEL _ ❑AUDITION _ _r❑-tREPA IR ❑RENEWAL []FIRE DAMAGE ❑DEMOLITION
❑ RESIDENCE ❑COMM OEDUCAIIONAL ❑GOV'T ❑RELIGIOUS I—IPATI'J ❑CARPORT ❑GARAGE ❑STORAGEOSLAB [:]FENCE
❑CONDITIONAL USF. ❑DESIGN REVIEW ❑COUNCIL APPROVED SIGNS
❑BOND ❑MOVING "— �'--
I " _FIRE ZONE__._ PLAN CHECK BY HEAT
OCCUPANCY.. _`.LAND USE ZONE BLDG.TYPE..FIREZONE--.—
"Ung Palo
c,rt r.t �/ K I.iv�lUj.i� P�IK:eas: g
OCC.LOAD FLOOR LOAD __HEIGHT NO.STORIES AREA VALUE
BUILDING DEPARTMENT SET BACKS FRONT REAR LEFT SIDE --.RIGHT SIDE
Permit
THIS PERMIT IS ISSUED SUBJECT TO THE REGULATIONS CONTAINED IN THE BUILDING C091i. ZONING
Plan Check REGULATIONS AND ALL APPLICABLE CODES AND ORDINANCES, AND I r IS HEREBY AGREED THAT THE
-- WORK WILL BE DONE IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS AND IN COMPLIANCE WITH
Recording AL, APPLICABLE CODES AND ORDINANCES. THE ISSUANCE OF THIS PERMIT DOES NOT WAIVE
RESTRICTIVE COVENANTS. CONTRACTOR AND SUB CONTRACTORS TO HAVE CURRENT CITI BUSINESS
1%State LICENSE, SEPARATE PERMITS REOUIRED FOR ScWER, PLUMBING AND HEATING.
Total _ 25By (}
_ APPLICANT OR AGENT
Approved Receipt No.
— A DPESS a ONE
p �
DATE INSP. TYPE INSPECTION REMARKS PLUMBING DAT
_t-71 Contractor _
Permit No.
Rough—in
— Fixture —___-
Final
-- HEATING
ContrL:for
Permit No.
Gas or Oil Rough-in —.-
Final
-- -
SEWER
Final
DRIVEWAY
Final -
Storm Drainage
(Rain Drainl Final
---_____------ -- [Final
alk
&Street Final
---- --- ,-- ach
BLDG.DEPT.FINAL TEMPORARY CERTI�ICATL OCCUPANCYCERTIFICATE OCCUPANCYcaping
g Final
i
I
i
I
i
i
72
✓li
J % t
1
1
,
st
\r
1 h r Iva
h,
r,
1
I