Loading...
11507 SW PACIFIC HIGHWAY STE D BUILDINGINFORMATION N -1__.. v pf,,,ri r .......... .0 . ll " c,k` IF, SP IFICAT10Ns G f. t I CJENERAL REQUIREMENT. 1.1 These notes are general in nature and are intended to set minimum ;fandards for Construction The drawings shall govern over the notes to the extent shown 12 The contractor is resp,,nsible for safe and clean lob site conditions - — 13 The builder shall \,erily all dimensions and conditions on different drawings and in the field and notify the architect of any discrepancies before proceeding 14 Do not scale drawings If a dimension is missing, notify the architect before proceeding 15 Final Cleaning A Remove all marks, fingerprints, du t, stains• manufacturers labels, soil, and defacement of all kinds from exterior and interior exposes surfaces included in the Work and from all r fixtlires and equipment provided under the Contract. B Repair, patch, and touch up maned surfaces Broom clean work areas 16 All work to be done in strict compliance with all governing codes and regulations SITE WORK ' 1 Demolition A Remove designated building equipment and fixtures, remo•.,e designated partitions and components B Remove or relocate existing electrical and mechanical equipment as necessary to allow new construction C Conduct demolition to minimize interference wifh adjacent building areas Maintain protected egress and access at all times D Remove demolished materials from site as work progresses 3 CONCRETE - not used 4 MASONRY - riot used 5 METALS ' 51 Lightgauge metal framring, A Drywall studs to be punched, 1/2' nominal flange width, 18 gauge, nominal depth 6-, 3 5/8or 4' as shown on plans Track to be specifically designed to match studs. —� unpunched B Screw fasteners For gypsum drywall of Plywood sheathing to studs, select a number 8 f rn shank phillips head sheet metal screw in /4" or I' length for 1/2 or 5/8' gypsum board ..i c� r14 4o i or plywood sheathing respectively, (41 6" oc edges and 12' oc field 4 a rM s, F; WOOD - not used THERMAL AND MOISTURE PROTECTION - not used 8 DCORS AND WINDOWS 81 Interior doors A Flush panel solid core wood doors to match existing C--- 92 Hardware - To match existing C/r' 9 F INISHE S Cr 91 Gypsum wallboard UJI cr n _ A Regular wallboard meeting requiremenf.s .of ASTM L 38 or 5/8 inch as shown on � t drawings. plain paper back LL Z a Wafer resistantgypsum board to be used at kitchen laundry and baths d B Perimeter sealant USG Acoustical Sealant" or approved a Z C supply, complete metal trim and accessnr,es LLr D Texture Walls to be or.arnge peel texture white finish, or match existing 44 9.2 Resilient flooring A. Resilient flooring to be selected by Owner/Tenant fromsamQ les provided by Contractor ti B Supply rubber base by Flex-Cove, Wanke or approved, 6` in restrooms and 4" elsewhere 93 Carpet ' A Carpet to be selected by Owner/Tenant from samples suppiied by contractor B Pad to be foam or sponge rubber type, in slab or wattle pattern (foam-backed carpet is an acceptable alternative) 9.4 Suspended Ceiling A Patch as requirod using tiles and tracks to match existing 95 Painting 1 A Use only "architectural fine" finishes that Is. the best qualify of the particular brand 1 selec.ed B Examine surfaces to receive coatings to assure that they are dry, clean, of uniform texture, free of bone, inhibiting foreiggn substances or other conaition that would adversely affect �.lJ y' 9 adhesion, protective prop4rfies, or coating appearance U i C Examine surfaces for moisture content D Do not start work until conditions are satisfactory < UJ 1, E Paint and finish colors will be selected by the Owner/Tenant 10 SPECIALTIES 10.1 Toilet accessories to be Bobrick or approved equal, see notes on plans Include .'4_x36 UJ Q '- mirrc,,toilet paper dispenser, stainless steel combination paper towel dispenser/waste I 1 8� r receptacle (semi-recessed) and soap dispenser UZ 10.2 Verify that blocking has been properly located to provide necessary support A Place accessories in location and height from floor as recommended by manufacturer or UO Z as indicated on drawings g �- u O ~ 1) EQUIPMENT not used Cl) U 12 FURNISHINGS {� < cor� 12.1 Kitchen Cabinrit - Selection by Owner/Tenant as supplied by Contractor. Final design by cabinet w Ln 4( U_supplier 5�0 u 13 SPECIAL CONSTRUCTION - not used 0-- _J cn 14 CONVEYING SYSTEMS - Not used 15 MECHANICAL 15.1 It Is the responsibility of the Contractor to provide compiate, workable mechanical systems. 152 Conform to all applicable laws and regulations, and p.nvide any dra,vings necessary to obtain required permits. Plumbing code minimum requirements sha.il supe•cede any lesser requirements slated in the contract documents. Arrange and pay for fees. permits or inspections 15.3 Conform to all accessibility requirements of the Uniform Buildi;)g Code. Oregon Struclural Specialty Code 15.4 Plumbing A Plumbing materials shall be installed as per the Oregon Stato Plumbing Specialty Code and the Oregon State Structurai Specialty Code B Install plumbing products approved by the State Plumbing Board or approved listing agency 16 ELECTRICAL } 161 If !s the contractor's responsibility to provide a complete, workable electrical system 4 16.2 The drawings are generally diagrammatic indicating approximate locations of outlets and wiring They do not show every offset, bend, junction box or other part which may be required to • complete the system r r 103 Set all switches and devices to conlwm. with ADA requirements Outlets to be a minimum of 15' above floor, swiiches to be a maximurr of 48' above floor unless otherwise notes 164 Conform, to applicable laws and regulations including the NEC and serving utility standards and provide any drawings necessary to obtain required permits Arrange and pay for fees, permit or inspec lions 16 5 Relocate recessed fluorescent fixtures as shown on plans 6-18-04 ^. '- �— REVISIONS. Pacific Hwy.#D, 11507 BUP2004-00288 2 of 2 04-1? a i • t- f I 41�,�>A 110'' NOTICE. IF THE PRINT OR 111II1i IIII'I ' I ((II( I III+ I ► ►11(111 VIII f ((I�tII I(t�flf 1(I(f(t I((If I Illlli Iljllllllllllll VIII i IIIIIII IIIIIII 11111 (1 VIII I ! ( VIII 1111111 I ( II`IIIIIIIIII ' lllllll ! 1111 I _ IMAGE IS NOT• ,S CLEAR AS THIS NOTICE, — I l� ---) � - I I 4� r r r IT IS DUE TO THE QUALITY OF THE No 96 ORIGINAL DOCUMENTIlli FIIIIIIi6II IIII IlillllllillllllllIIIilli ililllll6i ZIIIIIIIEiI ZIiIi(IIII�IIZIIILIIIIiI ZIIIilllUi(ffIIIIIII!VIII(ill(Ii�Illillill�lliilll(IIffiIIIIII;II11!II(I�Ill�llilll�l II I1(II III I flll IIIIIIIItI llllllI.0irltI1 IIII�IIIIIII�llllilll I L�lill1[illillllJ�l��llllil(III(IIIIlIIIII�.1. .� 1f1111��11 I� �le�ill ZIIIII8Z L9Z llZ I r