Loading...
Report (2) /148 c 2--cccig 5-2So st,I 54- Carrier United Technologies N2017 CITY OF TKAR SUBMITTAL ct —Untitledl Date Wednesday, September 21, 2016 1111111111111111111111MMINIMINImmm•••......-- 4 • Project: -Untitled1 Table Of Contents Pre•ared B : 09/21/2016 5t 08:02PM Unit Report 3 Certified Drawing Performance Summary ---------------------------------------- Unit Feature Sheet 5 Spec Sheet 8.5t 8 Unit Report 11 12 Certified Drawing 13 5 Performance Summary 18 14 Unit Feature Sheet --------------------- Spec Sheet - - 21 22 Packaged Rooftop Builder 1.41 Page 2 of 22 Project: -Untitled1 5t Pre.ared B : 09/21/2016 08:02PM 5t Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Spec Sheet Packaged Rooftop Builder 1.41 Page 3 of 22 Project: -Untitled1 Unit Report For 5t Pre.ared B : 09/21/2016 08:02PM Unit Parameters Unit Model:_ 48KCDA06A2A6-0B0A0 Dimensions (ft. ---- &Weight -- -- -- ---- -- ----- Unit Size: --- -- -- - --- --- 06(5 Tons) Unit Length: 6'2.375" Volts-Phase-Hertz:-_ Unit Width:_ -- ---- 460-3-60 - 3' 10.75" HeatingType: - Yp - - Unit Height:-_ -___ _ Duct - .Gas 3'5.375" 9:---- ---- --Vertical Supply/Vertical Return '' Total Operating Weight: .__ Low Heat 657 lb Single Stage Compressor Models "" Weights and Dimensions are approximate. not include unit packaging. Aprxiitimen ions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product Lines and Filters data catalog. Return Air Filter Type:_ _ Return Air Filter Quantity:__ __-__ -Throwaway --- --- Return Air Filter Size:_ 4 -- -- - __16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Temperature Economizer w/Barometric Relief Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCDA06A2A6-0B0A0 Roofto. Unit 1O Medium Static O.tion Belt Drive - Std leak Temp Econo IV with baro relief and W7212 control - AccessoriesMEI 33CS2PPRH-03 Edge Pro splitable 7-Day Programmable/Non-frog. - v Packaged Rooftop Builder 1.41 Page 4 of 22 X N A R W :. A t A ° Project: -Untitled1 Certified Drawing for 5t Pre•ared B : 09/21/2016 08:02PM NOTES 1. DIMENSIONS ARE IN INCHES, DIMENSIONS 1N [ ] ARE IN MILLIMETERS, ®�®, UNITED PO.BOX 4808 THIS DOCUMENT IS THE PROPERTY Of CARRIER CORPORATION 2. I TECHNOLOGIES SYpACUSL,05 A 0 IS DE LI VE REp UPON INf EXPRESS COXpI11 pX INAI THE SUBMISSION OI iXES(ORANINGS OA DOL UNEX tS CENTER OF GRAVITY 48HC 04 33 3/8 I 1® CARRIER 132P CoxTE1 wnL ED BE DiSnosm oX us(D wnxom uRRIER Dols 801 00 10 ur0 Pepr P[PIORMANCE oR [64 71 14774 13771 CORPORATI OX'3 WRITTEN CDNSEN T. CONNECTION O!CONTAA[i. 3. Edo,DIRECTION OF AIR FLOW 48KC 05 f847/18 43777P 18 5/B [3771 14721 48)/C 06 41 3/8 14 7/8 18 5/8 CONNECTION SIZES [705 ] [371 !4721 =1 3/8" [351.DIA FIELD POWER SUPPLY HOLE B 2' [501 DIA POWER SUPPLY KNOCKOUT ME1 3/4" [511 DIA GAUGE ACCESS PLUG 3341- /8 I D 7/8" [221 DIA FIELD CONTROL WIRING HOLE [8 =3/4,14 NPT CONDENSATE DRAIN 1/2"-14 NPT GAS CONNECTION 32 1/4 ECONOMIZER HOOD �2 1/2 1641 DIA POWER SUPPLY ANOCN-OUT FILTER ACCESS PANELIril [8181 (OPTIONAL) 16 (TOOLCESSS1 [4061 ' 1 THRU-TNE-BASE CNART I --•,� ( TNESE HOLES REQUIRED FOR USE ei� CRBTMPWAODIA01, 003A01 CCESS PANEL � � 7HREADEDNE REO0HLE CONDUIT SIZE USE SIZES (MA 1 @ —-y y ��A [6521 10-7/6 ♦ I 1/2" 7/8" [22.21 �__�•jajg [11171 llI 1�ni- -' RETURN AIA ��I [2771 1/2" I \\ AETHxx ms HANDLE 2-5/8-1 '\� �� AIR 3/4 (001,003) BACK 67] ` �� 1, ® 1003) 1/2"FPT TYP . FOR "THRU-THE-BASEPAN' FACTORY OPTION, CURB l' 1 .FITTINGS FOR ONLY X,Y, 8 Z ARE PROVIDED WIDTH E ALT. - ��� N CONDENSATE 4 DRAIN OPENING 14 29-3/8 .110 ® FOR POWERT DEPENDING ON W11RE2 SIZE !45918 I I, Z IN BASEPAN SUPPLY 26-1/2 10011 PROVIDES 3/4' FPT THAI CURB II AIR [6731 [7471 SUPPLY 1 16-1/8 14-I/4 12-1/4 I - AIR FLANGE d FITTING. [Al)) [363) [3121 SEE THRU THE I + + BASE CHART 6-1/d __________________________,_____ —_____=_____-_J � 25 ��` 12-1/8 ^ [8518 16361 4 FLUE 13071 78-7 " Wool TOPHOOD ia7oi2 ' f 1---- 4-5/8 [1181 .711/1 ELECTRICAL ,- 10-1/2 e ' DISCONNECT it— [265] f1/4c �iLOCATION132]LONDENSER =_ � �i�COIL B=q, CONTROL 608 =6' ACCESS PANEL INDOOR BLOWER H-----: G —— ACCESS E STD __ � CONDENSATE �� FILTER DRAIN OPTIONAL 1. �° '- 19-1/2 OPTIONAL 25-1/8 'INSTALLEDCONVENIENCE _ ��i �i4947FACTORY 16-3/4 16381OUTSIDE IOUTLET = L �u I:iFiI1 INSTALLED F RETURNHANDLE 11-3/8 [d271DISCONNECT I` AIRAIR _ 1� 6 i� [2891tI SUPPL Y�A7RII °°� [768] Py n ` .* i IS O. L—J 21-1/4 3-3/4 •��� ( �. 6-1/8 ���� [539] 7951 46-3/4 HANDLE — !7551 ��� [11671 30-1/8 L 8-3/B —���—SIL [7647 [213) ' 6-5/8 E 7 C 6 74-3/8 !1691 C1 T7] [152] LEFT [18887 26-7/8 [6821 31-1/4— BAROMETRIC FRONT SUPPLY [793] RELIEFLOW AIR RETURN SHEET DATE SUPERCEDES RIGHT111 AIR 1 OF 09-16-14 _ 48KC 04-06 SINGLE ZONE ELECTRICAL Packaged Rooftop Builder 1.41 COOLING WITH GAS HEAT 48KC000281 Page 5 of 22 Project: -Untitled1 Certified Drawing for 5t Pre.ared B : 09/21/2016 08:02PM STD. UNIT CORNER CORNER CORNER WEIGHT WEIGHT (AI WEIGHT (H) WEIGHT IC) WEIGHT CORNER UNITED P.o.DOA 4808 iMIS DOCUMENT IS THE PROPERTY Of CARRIER CORPORATION E'G' HEIGHT I I TECHNOLOGIES SR RACUSE.MX AMD IS DELIVERED UPON Tx[ERPRESS CONDITION PORI TXE SUBMISSION Of RRL RRAH]NGS oR RDCNNENTS ���®m��M®©v© �'91� CARA]ER 13211 CONTENTS HILL WRITTEN DISCLOSED OR USED WITHOUT CARRI[A DOES X01 COXSTITUiE PART PEALOANANC[OR Sfi� CORPORAiIOX'S WR]iTLN CONSENT. ACCEPPAN[E Of CDNIRACi. 24 3/4 1628J Imam 48NC 06 ELIMEEMILIIIm®m®m®mIILIKEMI STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACNAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG, CORNER A CORNER B 0 , SMR s I CORNER DL'---1-11--- x CORNER C TOP 'I'li.ff, Ili 0 2 , . „. •• 00 �° .� 00 ki FRONT SHE17 DAT[ SUPERCED[S 20F2 09-16-14 _ 48KC 04-06 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48KC000281 III Packaged Rooftop Builder 1.41 Page 6 of 22 Certified ertified Drawing for 5t Project: -Untitled1 09/21/2016 Pre•ared B : 08:02PM Service Clearance 1111110111* ..% ' 1 % .„,,f,... t. a------ --,. sz, , ,::•,- •-:>, LOCATION DINIENSiON CONOMON £05337 45-in(1219 mm) • ce A 18-in(457 mm) :RNeocodismcmed% °nnnec:ernreienoutlet option dearance 12-in(305 mm) laZDEMIEM 42-in(1067 mm *Surface behind servicer is:rounded te.:.,metal,masonry wall) B 36-in 514 mm IZEZIEMD IIME=21. *Check for sources of flue products within la-ft.of unit freshair intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) iniii1m5syIt1 . EMEMIIM •No flue dischart e access installed,surface is combustible material 42-in(1067 mm) •Surface .., . . ..behind servicer is grounded(e.),,metal,masonry wall,another unit) 0 3540(914 min) ial •Check for adjacent units or building fresh air intakes within 10-ft of this unit's Spec flue outlet NOTE:Unit not designed to have overhead obstruction.ContactApplication Engineering for guidance on any application planning overhead obstruction or vertical clearances. Chasms 1,2 Packaged Rooftop Builder 1.41 Page 7 of 22 • Performance Summary For 5t Project: -Untitled1 Prepared By: 09/21/2016 08:02PM Part Number:48KCDA06A2A6-0B0A0 ARI SEER: 14.10 Base Unit Dimensions Unit Length• Unit Width. 74.4 in Unit Height. 46.8 in Operating Weight 41.4 in Base Unit Weight- Medium Static Option Belt Drive. 597 lb Temperature Economizer w/Barometric Relief: 10 lb 50 lb Total Operating Weight* 657 lb Unit Unit Voltage-Phase-Hertz• Air Discharge. 460-3-60 Fan Drive Type: Vertical Actual Airflow:__ Belt Site Altitude 2000 CFM 0 ft Cooling Performance Condenser Entering Air DB: Evaporator Entering Air DB• 95.0 F Evaporator Entering Air WB• 80.0 F Entering Air Enthalpy 67.0 F Evaporator Leaving Air DB• 31.44 BTU/lb Evaporator Leaving Air WB• 58.6 F Evaporator Leaving Air Enthalpy. 57.3 F Gross Cooling Capacity 24.57 BTU/lb Gross Sensible Capacity. 61.84 MBH Compressor Power Input 46.23 MBH Coil Bypass Factor 5.19 kW 0.058 Mixed Air Outdoor Air Airflow. Outdoor Air DB• 420 CFM Outdoor Air WB• 95.0 F Outdoor Air Htg. Temp • 77.0 F Return Air DB• 35.0 F Return Air WB• 76.0 F Return Air Htg.Temp • 64.0 F 70.0 F Heating Performance Heating Airflow: Entering Air Temp• 2000 CFM Leaving Air Temp• 70.0 F Gas Heating Input Capacity: 97.3 F Gas Heating Output Capacity: 72.0 MBH Temperature Rise• 0.0/59.0 MBH 27.3 F Supply Fan External Static Pressure. - Options/Accessories Static Pressure 0.50 in wg Economizer: Total Application Static(ESP+ Unit Opts/Acc.):_ 0.12 in wg Fan RPM:_ 0.62 in wg Fan Power 1248 NOTE• 1.22 BHP Selected IFM RPM Range: 1035- 1466 Packaged Rooftop Builder 1.41 Page 8 of 22 Performance Summary For 5t Project: -Untitled1 - Prepared By: 09/21/2016 08:02PM 4 Electrical Data Voltage Range. 414-506 Compressor#1 RLA• 7 Compressor#1 LRA• 52 Outdoor Fan Motor Qty• 1 Outdoor Fan FLA(ea)• 0.9 Indoor Fan Motor Type• MED Indoor Fan Motor FLA• 4.2 Combustion Fan Motor FLA(ea)• 0.25 Power Supply MCA• 14 Power Supply MOCP(Fuse or HACR)• 20 Disconnect Size FLA• 14 Disconnect Size LRA• 90 Electrical Convenience Outlet. None Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 87.5 87.2 87.5 125 Hz 82.7 79.5 82.5 250 Hz 75.5 66.6 76.1 • 500 Hz 71.2 63.9 73.6 1000 Hz 67.8 63.2 71.3 - 2000 Hz 62.1 57.3 67.1 4000 Hz 63.9 53.2 64.1 8000 Hz 59.5 45.7 60.0 A-Weighted 74.6 69,2 77.0 Advanced Acoustics 12 illi 114 i 0 ,,� ;,, as lit 0 a 01 g ..,(% Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft - 4. Height of obstruction• 0.0 ft - 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Packaged Rooftop Builder 1.41 Page 9 of 22 • Summary Performance For 5t Project: -Untitled1 Prepared By: 09/21/2016 - 08:02PM Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 87.5 82.5 76.1 73.6 71.3 67.1 64.1 60.0 8R9.27 9.2 Lw B 61.366.467.570.471.368.365.1 58.976.7LwA C 55.1 50.1 43.7 41.2 38.9 34.7 31.7 27.6 56.8 Lp D 28.9 34.0 35.1 38.0 38.9 35.9 32.7 26.5 44.3 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other AS HR Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2.0 pan Curve ��/ �/ % % , �� �. 190}�A1A 1.8 o�' ,��� �,'a i poi .� , i q �� /, % �4�% • Unit Feature Sheet for 5t Project: -Untitled1 09/21/2016 Prepared By: 08:02PM ( Carrier ) • WeatherMaker' — 48KC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS-14 SEER 3,4,5 TONS • STANDARD FEATURES INCLUDE: •e LUDT!(R-410A)HFC refrigerant di,* dskddiddirld•rdri•dilTd did di I •Meets and exceeds ASHRAE 90.1 energy effioliancyleve 9is •Scroll compressors with witernal to break and overload protection dd•„lid•dird•••41,di. rd did Add, •Single-stage cooling capacitycontrol •SEERS up to 14.0.EERS up to 12.0 or! *Acutror•refrigerant metering system f dr'did, dkfddrifiedid, , •Exclusive 4'on-eotrasive composite condensate pan in accordance with ASHRAE Standard 62.sipping design.side orcenterdrarn * Standard waking operation tip to 115dF(46'iC)and down to 40'F(4dC) drost„ite - down to F(-4'C)with venter start kit. 'weskit • • Pre-painted exteriorpanels and primer-coated interdorpanels tested to 500 hours sort spray protection •Fudy insulated cabinet *Exclusive IOC solid-state control for on-board diagnostics with LED error code designation bumeroontroi logic and energy saving indoor fan motor delay **,441111fi fi, •Low NOx models that meet California Air Duality Management , 17, / Puron Induoeci draft gas heat co rnbustio n design CORI ° •Redundant gas valises with up to two stages°cheating *Low pressure and high pressure switch protected. MAINTENANCE FEATURES: •Access panels with easy gekt handles • Innovative easy starting,no-strip screws on unit access panels •Two-inch disposable return arrniters and Tool-1 Star access door WEATHERMAKER SERIES • Direct Drive-ECM indoormotor is standard with optionalbelt drive systems WeatherMaker 48KC (14-SEER) units are one-piece gas •Terminal board facilitating simple safety circuit troubleshooting and heating,electric cooling units that are pre-wired and charged simplified control box arrangement with%ion(R-410)refrigerant. They are factory tested in both •Exclusive IGOsofid-state control for on-board diagnostics with LED heating and cooling modes,and rated in accordance with AHRI error code designation,burriercontrof log DC and energy sa ving indoor Standards 210/240. Weatherldaker units are designed in fan motor delay. accordance with UL Standard 1995, and listed by the IN STALLAT/ON FEATURES: Underwriters"Laboratories. •Thru-the-bottorn powerentry capability •Single point gas and electric connections • Ful perimeter base fall with rigging adapters and fork slots Approved and certified by: • Field convertible from vertical to horizontal airflow STANDARD WARRANTY: 4ataa*MiCERTINED. • 10-ye arheat exchanger-15-year stainless steel option Ve+MmdMiliC,102, •40 SlA leo*.4FriVAP MAINAKIX,M c „ us 5-year compressor • 1-yeargada • fitany optional upgrades also evadable WOO,.F4,MeAvAbre. toentrAt4r prZhoe, OPTIONS INCLUDE BUT ARE NOT LIMITED TO: ..aaa,aaa,,,aayaq PremierLink and RTU Open Mufti Protocol DOC Controls • Supply and litetum Air Smoke Detectors,high static motors Louvered condensercoil guards • Disconnect switch and convenience outlet options • Stainless Steel he at exchange r option • Corrosion resists:stood coating. Certified to ISO 9001 • High static motor options • Patented r•adaptive dehumidification system.This option also includes Motorrnaster I controls • Hinged access panels • Integrated ecortommersystem.Standard and Ultra Low Leak versions Fore complete list of Options and accessories referto the Product Data Catalog forth is unit. Packaged Rooftop Builder 1.41 Page 11 of 22 Spec Sheet for 5t Project: -Untitled1 Prepared By: 09/21/2016 08:02PM Packaged Rooftop Builder 1.41 Page 12 of 22 Project: -Untitled1 8.5t • Prepared By: 09/21/2016 08:02PM 8.5t Tag Cover Sheet Unit Report Certified Drawing Pfmt .,:i UniterorFeature ance Rs Sheet Spec Sheet Packaged Rooftop Builder 1.41 Page 13 of 22 • Unit Report For 8.5t Project: -Untitled1 Prepared By: 09/21/2016 08:02PM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Model: 48TCDE09A2A6-0BOA0 Unit Length• 7'4.125" Unit Size• 09(8.5 Tons) Unit Width- 4' 11.5" Volts-Phase-Hertz: 460-3-60 Unit Height. 4' 1.375" Heating Type• Gas *** Total Operating Weight. 1099 lb Duct Cfg• Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size: 1/2 Condensate Drain Line Size' 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 20 x 2 Unit Configuration Medium Static Option (Belt Drive) Al/Cu-Al/Cu Base Electromechanical Controls Temperature Economizer w/Barometric Relief Standard Packaging Humidi-MiZerTM Adaptive Dehumidification System • - Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDE09A2A6-0BOA0 Rooftop Unit 1 Base Unit Std leak Temp Econo IV with baro relief and W7212 control None Accessories 33CS2PPRH-03 Edge Pro splitable 7-Day Programmable/Non-frog. 1 Packaged Rooftop Builder 1.41 Page 14 of 22 1 . 1 1 I . . 1 . . t t Certified Drawing for 8.5t Project: —Untitled1 Prepared By: 09/21/2016 08:02PM NOTES - - - �UN1T OUTDOOR 3 R H UNITED P 0.B00 4808 THIS DOCUMENT]S INE PROPERTY OE CARRIER COBPDRAEION 1. DIMENSIONS ARE IN INCHES, DIMENSIONS COIL TYPE TECHNOLOGIES srRAcwE.Nr AND Is 81001800 4108 THE I188EO4 memnON lUST INE SUBMISSION or THESE DRAWINGS o0 DOCUMENTS IN [ ARE IN MILE IME7ER5. - CARRIER o TENTS WILL NOT BE DISCLOSED ON USED WIINODT CARRIER DOES NOT CONSTITUTE PACONTRACT s PEFroFNAxcE OR 481C A08 RTPF 47 1/4 33 15 7/8 CORPORATION'S WRITTEN CONSENT ACCEPTANCE O ox TB A<l. 2. • CENTER Of GRAVITY - [1048] 1658] 14031 13231 481C A09 RTPF 49 3/8 37 1/4 27 7/8 CONNECTION SIZES [1253] 19461 17181 3. .100„DIRECTION OE AIR FLOW -- _ (48TC-Al2 RIF 49 3/8 37 1/4 15 7/8 A 1 311" [35] DIA FIELD POWER SUPPLY HOLE (7253] 1946] [4037 40-3/81-7 41 1/4 33 75 7/8 PLUG [1026'' B 2 1/2" [641 DIA POWER SUPPLY P100 KNOCKOUT 4C DU8 RTPF 17048] [658] 1403] —TFCC 1 3/4" [51) DIA GAUGE ACCESS 4610-D09 RTPF 49 3/8 37 1/4 15 7/8 f [7253] 19481 14037 0 7/8" 1221 DIA FIELD CONTROL WIRING HOLE 48TC-D12 RIFT 49 3/8 37 I/4 75 7/8 ECONOMIZER HOOD 20-3/4 E 3/4' 14 NPT CONDENSATE DRAIN 4151/4 C933] [4037 - [OPTIONAL) [527] F 1/2"-14 NPT GAS CONNECTION [ 48TC-D08 MC HM_[10.48] 1658] [584.2] 3/4"-14 NPT GAS CONNECTION_ 49 3/8 37 1/4 11 [ G 12 ' [511 DIA POWER SUPPLY KNOCK OUT 1,18/C-D12 MCHN ([7253] (946] [279.4] __ LRTPF - ROUND TUBEFIN PLATE lCOPPER/ALUMS- I THRU-THE-BASE CHART (FIELD ;UST) MCHX- NOVATION (ALUM/ALU THESE HOLES REQUIRED FOR USE WITH ACCP NITS: • !21.7-5,17-7-1\\ 363/8 — 12-5/B• CRBTMPWR002A01; GAS THRU CURB ,.�1i;I 4114 .,•.,._ 19251 [3211 CRBTMPWR 004A 01: GAS THRU BASEPAN —. �1[I,,,;��/////�--•� RETURN AIR RETURN AA / AIR [DREADED WIRE REVD HOLE 1 ID CONDUIT SIZE USE SIZES IMAX-1 FILTER ACCESS PANEL y W 7/2" ACC. 7/8" [22,21 11001 LESS) I� ,,.....=,,," E ALT - X 1/2 24V 7/8' [22.21 • CONDENSATE 'I CONDENSER "�L �DRAIN OPENING Y 1 1/4 (002,DDdl POWER 1 3/4" 144-4] COIL IN BA$CPAN 28-3/4 17 31) 37-5/8 40-318 :Ill: I� + (004) 3/4' FPI GAS 1 3/4" [44.4] INDOOR Coll '� I�IIU a11mJ/JJiEll w suPPLr [sssl no2n U.7��AQQ �����Z,I X SEE THRU AIR 1002) PN 01115 3/4" FPI THRU CURB ACCESS PANEL y THE BASE SUPPLY B ACf{ [18 469]16 14 I=�\\\���I CHART AIR + FLANGE 8 F7TTI NG. HOLE SIZE 2" (50.87 moo`._ Id12] 13557 71 U 1 _ rz791 �-1 THRU-THC-BASE CHART (FIOPI_ T- � � ]ISI - ���� —_�I FORT]NGSUF THE OR OBASENLY %ANY FAC1ORY OPTION, —� FOR BELOW LISTED MODELS, A FIELD 1- 6.1/4 ++ SUPPLIED 1/2" ADAPTER IS REQUIRED DED ++ L. 29-5/8 [100] FLUE -3.1/4 11591 BETWEEN BASE PAN FITTING AND GAS VALVE [751] HOOD 1831 48HCD,5.08 14 (356] TOP [5-7/2— 641] 1-1/4 4-588 (327 11-7/8 [ [302] 1181 • ELECTRICAL ALOCATION DISCONNECT CONTROL BOO FILTER - II LOCAL ON ACCESS PANEL CONDENSER COIL N. E STD. CONDENSATE OPTIONAL I I OPTIONAL INDOOR BLOWER DRAIN 1 , FACTORY ACCESS �_ FACTORY 27-7/8 INSTALLED ' ]NSILLED D 1709] • DISCONNECT r CONVENIENCE � li_ F -HANDLE 13-1/6 [706]27 4 OUTSIDE OUTLET �_ 6 334] 1I si SUPPLY AIR L _Er _ _.— ., .�� 6,5/8 HANDLE-Th �j� /_�_ I [659] 4411 '2' 14611 [957 - -- 591/2 2-5/8- [1510] 167] f 6-5/8 TYP H —19 - 2748 [167] _ 37-7/8 [177] 6-1/8 4-3/8 _.. --_ter LEFTCURB [940: [962] [1557 [1131 W]D]H - - --88 1/8 — 42-3/8 12238] SUPPLY [10751 BAROMETRIC FRONT AIR RETURN FLOWEr RIGHT I SHEET DAT[ SDPERCEDE$ 48TC 08-12 SINGLE ZONE ELECTRICAL 810 012 03-08-10 11-24-08 j COOLING WITH GAS HEAT 4810500985 r Packaged Rooftop Builder 1.41 Page 15 of 22 r r . ■ 1 . E) Certified Drawing for 8.5t Project: -Untitled1 09/21/2016 Prepared Un By: 08:02PM I SID. UNIT CORNER CORNER CORNER CORNEA �j UNITED v o-e0 WA THIS oocuu[rvt is tuE awO[0N1 or CARRIER CORPORATION UNIT OUTDOOR WEIGHT WEIGHT IA) WEIGHT (BI WE 1380 (C WEIGHT (DI TECHNOLOGIES SYRACUSE.ur AND IS DETINERNDD UPON THE EMPRESS CONDITION THAT THE SUBMISSION or THESC OAgwI NGS OA DOCUMCNTS COIL TYPE — C.G. CARRIER COxT[x15 W,LL BE D15C OSED oA us"w1 THDUT URF LH DOES NOT CONSTITUTE RT PERTORMAUC7 OR LBS KG LBS. KG. LBS KG. LBS. NG. LBS. RG. X EORPORAT1orvs rRinery EauservT ACCEPTANCE or ox RncT. 48TC-A06 FERE 780 354 178 81 158 72 2D9 95 236 107 41 1/2 [1054] 33 7/8 [860] 20 1/2Z[5217 044 STANDARD UNIT WE]GH7 15 WITH LOW GAS HEAT AND WITHOUT PACKAGING. 48TC-A09 RUE 920 418 i 212 96 183 83343 110 282 128 40 7/ FOR OTHER OPTIONS AND ACCE SSOA IES REFER TO THE PRODUCT DATA CATALOG. 48TC-Al2 RTPF 8 [10381 14 [8647 23 1/B [587] 930 422 216 98 186 89 247 112 272 123.5 42 110671 33 1/8 !8411 24 1/4 [616] 481C-DOB RTPF 835 379 164 74.5 170 77.2 255 115.8 246 111 7 44 7/8 [1140] 35 5/8 1905] 19 3/8 [4921 48TC-D09 RIPE 930 422 228 103.5 187 85 232 105.3 283 128.5 39 3/4 f10 u] 32 7/8 [8357 18 5/8 [473] 481C-D12 KW 940 427 731 104.9 189 85.8 234 106.2 286 129.8 39 3/4 110101 33 [838] 18 1/2 14707 487C-008 4CH4 805 3655 160 72.6153 69.5 240 109 26D 118 43 110927 36 3/8 [924] 20 3/8 [517.7] 48TC-512 4944 895406.3 185 84 176 79.9 260 118274 124 4142 7/8 11089]_35 1/2 [902]1 22 7/8 [581] RTPT - ROUND TUBE, PLATT FIN (COPPER/ALUM) _ MCNM - NOVATION (ALUM/ALUM)__ CORNER A CORNER B / ) [X11 IT�u /Ill/7/%Tei!, \ f CORNER D L CORNER C TOP F x _ • 1 1 A • .•„,. =__ 1:400 Sr_f I : 00r. FRONT SHEET i N — SUPERB.. IS TC 08 12 SINGLE ZONE ELECTRICAL REP 2 01 2 103 08 10 11 24 08 C 1 48TM500985 —— COOL NIH GAS HEAT F Packaged Rooftop Builder 1.41 Page 16 of 22 Ift a . r • Certified Drawing for 8.5t Project: -Untitled1 Prepared By: 09/21/2016 O8:O2PM Service Clearance f - B ''k'.*:''''i A mss, -',> CI1247 LOCATION D€MENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel 35-in(914 mm) •If dimension-B is 12-in(305 mm) A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended service clearance(use electricscrewdriver) 12-in(305 mm) •Minimum clearance(use manual ratchet screwdriver) 35-in(914 mm) •Unit has economizer B 12-in(305 mm) •If dimension-A is 36-In(914 mm) Special •Check for sources of flue products within 10-ft of unit fresh air intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessoryinstafled,surface Is combustible material 42-in(1057 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) D 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Gam 3tla Packaged Rooftop Builder 1.41 Page 17 of 22 Performance Summary ����r 8.5t Project: -Un�|ed1 09/21/2016 Prepared By: O8:O2PK8 Part Number:48TCDEO9A2A6-0BOAO ARI EER. 11OV lEER(Max Cooling at Normal Cooling Design Mode): 1- 7 Base Unit Dimensions Unit Length. 88.1 in Unit Width. og—� in Unit Height. 49.4 in Operating Weight Base Unit Weight 930 lb Two Stage Compressor Models with Al/Cu condenser Coils and Humidimizer 80 lb Medium Static Option (Belt Drive) 15 lb Temperature Economizer w/Barometric Relief 74 lb Total Operating Weight: 1099 lb Unit UnitVo|togo'Phaoo'Hertz. 460'3'60 Air Discharge. Vertical FanDhvoTypo. Belt ActualAirOow� 3000 CFM Site Altitude. oft I Cooling Performance Condenser Entering Air DB 950 F Evapom0orEn0ehngAir DB. 80.0' F Evaporator Entering Air WB g7O F Enoehng/UrEnthalpy: �1�'4 BTU/lb Exapom0orLoavingAi,DB. 57.8 F Evupou�orLaavingA/rVVB. 56.4 F Evaporator Leaving Air Enthalpy 24.00 BTU/lb Gross Cooling Capacity 100'42 MBH Gross Sensible Capacity: 71.96 MBH CompneoaorPowar|nput. 7.18 kkWCoi| 8ypaaoFunior V. 041 Heating Performance Heating Airflow. 3000 CFM Entering Air Temp 700 F LoavingAirTomp- 101.8' F Gas Heating Input Capacity 1250 MBHGaoHnadngOutputCapaoity. 103.0' MBH Temperature Rise. 31.8 F Supply Fan External Static Pressure Opki«no/A000anohanSto1/opmanum 0.50 in wg Humidi-MiZer Dehumidification System 013 in wg Economizer. � Total APP|ioadonStudo(ESP+ Unit O[ta�,00). 0.11 in wg Fan RPM: 0.73 inw� 756 Fan Power 1.20 BHP NOTE• Selected IFM RPM Range: 690-936 - Electrical Data Voltage Range* 414- 506 Compressor#1 RLA:� 6.3 Compressor#1 LRA. 55 Compressor#2 RLA. 6.2 Packaged Rooftop Builder 1.41 Page 18 of 22 • Performance Summary For 8.5t Project: -Untitled1 09/21/2016 a Prepared By: 08:02PM Compressor#2 LRA: 41 Indoor Fan Motor Type• MED Indoor Fan Motor FLA• 3.4 Combustion Fan Motor FLA(ea)• 0.25 Power Supply MCA• 20 Power Supply MOCP(Fuse or HACR)• 25 Disconnect Size FLA• 20 Disconnect Size LRA• 128 Electrical Convenience Outlet. None Outdoor Fan [Qty/FLA(ea)]• 2/0.8 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 96.5 93.7 88.6 125 Hz 90.8 84.0 85.0 250 Hz 75.0 67.6 81.6 500 Hz 68.8 63.8 79.5 1000 Hz 64.0 61.2 77.4 2000 Hz 62.0 56.4 74.1 4000 Hz 65.0 55.8 71.0 ` 8000 Hz 65.3 55.1 66.3 t A-Weighted 77.7 72.2 82.0 t Advanced Acoustics til 04IS f �w F w S to t r 0 Advanced Accoustics Parameters 1. Unit height above ground• 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground• 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction• 0.0 ft Detailed Acoustics Information r Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.6 85.0 81.6 79.5 77.4 74.1 71.0 66.3 91.4 Lw B 62.4 68.9 73.0 76.3 77.4 75.3 72.0 65.2 82.6 LwA C 56.2 52.6 49.2 47.1 45.0 41.7 38.6 33.9 59.0 Lp D 30.0 36.5 40.6 43.9 45.0 42.9 39.6 32.8 50.2 LpA Packaged Rooftop Builder 1.41 Page 19 of 22 Performance Summary Project: -Untitled 1 9/21/2016 For 8.5t 08:02PM 0 Prepared By: I t Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A Weighted Sound Pressure Levels at Specific Distance from Unit, LP Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 2.0 FanCurve Ftri' „ \/ 18 aq 4 1.6 r, l% i % raj/1 t e �� , i r / . '1.4 — VAj 1 rr � /�/ t N 7 M 11/44/'''''''''' //// -----------, ._,,. \''''''ii:?'7‘7,1:',4K:li,4!,AIW -- '-"'%„,?,' ',A,t/,:, ':- \ \„s\ 7 --_ �/ r �j /� r�r� oil to (n / \///// E lG 1---- //j/,\ 22 a- eamm v 0.8 %y SOCA ���` �� ° i/G i 02- 3CC�P 0.0 0.5 1D 1.5 2.0 2.5 3.0 3.5 4.0 45 5.0 5.5 Airflow(CFM-thousands) RPM=756 BHP=1.20 Maximum RPM=1400 MaximumBHP=3.70 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-System Curve RP-Rated Point t I Packaged Rooftop Builder 1.41 Page 20 of 22 Unit Feature Sheet for 8.5t Project: -Untitled1 Prepared By: 09/21/2016 08:02PM WeatherMaker' — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3,4.5r 5,7,5,8.5,10,12.5,15TONS STANDARD FEATURES INCLUDE: •Puron(R-4 b A3 HFC refrigerant dig/�w aG 0/ r rgy.ontpt ant ��`° �'/fa i �il F I ���i�,a�/ v i �i n •ASHRAE�.1 enc Scam ru 9 ''�mr� ir✓ �! • ' °„ ���/ %� � � • cornpn=ssoas WOO internal fine break and overload protection`j S ngk*stage cooing c apsci y cantrolon 04-12 models • �; i�� / ✓ � , •Two-stage cooing capacity control on 08-15 models er SEERS up to 13.0,EERsup to 11.1 and lEER's up to 11.8 •Acutroi-v refrigerant metering system rl • EsIee non-corrosive composite condensate pan in accordance with ,q� ASHRAE Stends'd 82,slops de �r ` �/ • g sem,side aroenterdra� " Standard coodng operation up to 115'F(46'C)and down to 40'F(VC) • %/%i�� it r%� r yr„w �b '. -clownto25`F{-4 c,,e'thwinterstart kit. ! • Pre-painted extenls arpaneand pririe'-coate3interior panels tasted to j r500 hours salt spray protection •Fu'y insulated cabinet , °� �i�/h/a✓i; ` •Exdusnne!GC solid-state�traifor onkbazasaJ d3ay�nastics�.vith LED, � - error code de nationbumerrsontroll and energy saving indoor 8/(111,1C fan motor delay Op t2Ofl21 Louvered Hail Guard Shown *Low NOx nximeet that eei California Air Quality falanagement • Induced>d•:raft gas heat combustion design •Redundant 335.5 iSS.%'t'l up tO two stages of lest ng •LOW pressure and high pressure switch protected. to MAINTENANCE FEATURES: �y raAccess panels with easy 9iiphandles S .Innovative easy starting,no-strip sews onuna`taccess panels a(,;1,' f.� •Two-inch nc derposa5ieretum akfiiters and Tool-fess feet access door CO •Direct Drive ECA4 on 3 to 5 ton(-5 voltage only}models and beltd-ve evaporator-fan motor and pulley combinations eva bleonaltmodels WEATHERMAKER SERIES • terminad boardfat tatingsimple safetycircudtroubleshooting and simplified oontrol box arrangement eathert aker{48TG)unitsare one-piecegashea€ing,electric •Exclusive teCsol.d-state control for on-board diiagnostics'Nth LED cooling units that are prefanrmstarwired and charged with Puron rrorotor des rat n,bumeram�tra3 gcaradenergy sarngindoor IR-410)refrigerant. They are factory tested in both heating deldes and cooling modes; and rated in accordance with AHRI INSTALLATION FEATURES: Standards 210/24D (04-06 sizes) and 344356o (07-16 sizes). •Thai-Me-bottom power entry capability WWeatherMaker units are designed in accordance with UL •Ssrglepoint gas and electric connections Standard 1995,and listed by the Underwriters'Laboratories. •Fug perimeter base rail with built-8 rigging adapters and forks its •Field convertible from vertical to ho€.zontal airflow for stab rrawnting. 05 size models require field"notaled supply duct cover). Approved and certified by: STANDARD WARRANTY: • 10-yearheat exchanger-15-ye sr stainle so steel option r fit RICE CT * 5-yearcanrpressar C (2) • 1-yearparts u a w creme • 3-yeerparts on 1.ovat p"Condenser co 5-where availNON Wat 4444,044444 •Many optional upgrades a35oavalable m OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • Psetniert.inky"and RTU'Open Ulul¢I;Protraro9 0DC Controls • Supply and Return Aar Smoke Detectors,high static rotors COM • Louvered condenserax guards • • Economizer,disconnect and convenience outlet options • • Stainless Steel hest exchangeroptaon • Conos on resistant coil coating. • ytumisfs-t1Zer`adapterdehumidificationsystemevadableonail • Certified tCiISO 9001 'nodes with RTPF condenser oohs-Motor Master I controlierinoluded • Hinged access panels Fo a=vete§statapkesand amasse r/a" 1 See O'r)?JG1 Zra Catacg tar Vss to% Packaged Rooftop Builder 1.41 Page 21 of 22 Spec Sheet for 8.5t Project: -Untitled1 09/21/2016 I Prepared By: 08:02PM I $ V Packaged Rooftop Builder 1.41 Page 22 of 22