Loading...
SW DURHAM ROAD RIVER VIEW II rw.......rM•,, •-...nM.ww..�-.•+..:�•...a�.:.�.�u•l,w+'q•+w�M.'..-•_ -'-Kwnw•w.�WWWr�w�Y o.r.��wur+�IfN«•+��u-a+�'M.uwrw�'+�w�.r+y�•ww�wr'eN.+hr�+t:�•u*..•,�.,w+w«a�Nr•rwn+W.+•YWWranNµ�M�4�Ma.'.�•wOW1';�IyW�W. N H H H H /I rf I 1� i --�- >URHAM ROAD -- RIVER. VIEW II ('rrnsrracli-' l nspecrian & Related i Isla �.i Testing, Inc* � P.O.Box 2:3814 �— Tigard,Oregon 97281 g 19 9 2 Phone;503)684-3460 Ai: us t 2 6, FAX 0 684-0954 #CP-7636 FIELD INSPECTION REPORT DATES COVERED: August 24, 1992 PROJECT: River View II ADDRESS: Tigard, Oregon INSPECTOp: C. Stasch ive ro(:k 8-24-92: CTI represenroximately�9 � an placd Lot 7 ed observed compacted contractor had excavated down app request in bottom of ts an hole•return laterinday to taken density s tests rock. CTI will on soil . eria]. tested/inspect mat Our reports pertain to the exceptli� on Informationcontained authorization ai ed her n from this office. , P ior ful' , witho p If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully submitted, CARLSON ZEST NO, INC. r Douglas W. Leach President 110 cc: Sierra Pacific Development, Inc. OTAK, Inc . City of Tigard L.S. Henriksen Construction C'onso,uction 1»shection & Related "Pests Carlson Testing, Inc. P.O. Box 23814 JOR NO - _ Tigard,Oregon 97261 REPORT ?F IN 'LACE SOIL DENSITY TESTS('" ,,44r,'101)X#68 -095 460 X#684-0954 SIERRA PACIFIC DEVELOPME'T 1N . Client ---- ----- RIVER VIEW II Project DURHAM RD , TIGARD OR — ------ - ---- _-----_.__-- ---- Soil Description SILTY SAND Max. Dry Density 9t3-_ -_ Ibs./cu.ft. Optimum Moisture_--20 4 45 Method of Test AASHTO T-99 Serial# 20998 NUC 3440 DATE OF TEST ELEV. LIFT MOISTURE E IN-PLACE D � TEST N0. TEST LOCATION FT. NO. % wet oar COMPACiIUN 08-24 1 LOT #7 -7 .!� ' 13 .8 110 .2 96 .9 98 . 1 08-24 2 LOT #7 -2' 12 . 1 105 .1 93 .8 95 .0 rITY or , r r, Remarks: ._____ 1Vt � -- — – Teated by -- 8 1.EACH/ME;HJ._._ CARLSON TESTING INC. Information contained herein is not to be reproduced, except in full, without prior authori+ation from this office. 4 Comstruction Inspection&Related Tests Carlson 'Testing, Inc. rte-7636 — - P.O. Box 23814 JOB NO. ___._.__ — Tigard,Oregon 97281 REPORT OF IN-PLACE SOIL DENSITY TESTS`'L'V 25 F'�1gne(502)684-3460 1`' -FAX#684-0954 SIERRA RAC_IFIC DEVELOPMEN'r INC Client - ----- — -- — -- RIVER VIEW 11 Project -J;�l IRHA.M RU I T T GAIRD--0R --- -- __ --- Soil Description SILTY SAND' Max.Dry Density 98 .8 ___lbs./cu.ft. Optimum Moisture -__ 20 •4 _ % Method of Test AASHTO T-99 Serial 0 12400 NUC 3411E DATE OF TEST ELEVLIFT MOISTUREIN PLACE DE DENSITY % TEST N0. TEST LOCATION FT. N0. a ,T DAY COMPACTION 08-24 1 LOT #7 — -5 ' 14 .9 110 .8 ^h .4 97 .E 08-24 2 LOT #7 -5 ' 18 .7 111 .7 94 .1 95 .2 Remarks: TTY OF TIGARD —_�.— _._-- I HF'NR LK-IEN CC)hd,�TRl IrT I� 0 IN Tested by H _ _ — CARLSON TE ;TINC INC. Information :ontained herein is not to be reproduced, except in full, without prior authorization from this office. construction I nspertion & Related Tests Carlson Tesfing, 'Inc. _ P.O. Box 23814 Tinard,Oregc n 97281 August 24, 1992 Phone(503)684-3460 #CP-7636 FAX #684-0954 FIELD INSPECTION REPORT DATES COVERED: August 21, 1992 PROJECT: River View II ADDRESS: Durham Rd. INSPECTOR: M.F. Schrieber, P.E. 08-21-92: Arrived at contractor's request. Excavator is in the process of removing unsuitable black and very soft gray organic clay that contains significant organics . Bottom of the excavation consists of a subgrade soil that is firm greenish gray silty clay containing trace of sand. Recommend that we are called out to see the bottom of the excavation before backfilling. Contractor wishes to use brawn sandy silt material for engineered backfill. . Recommend that a 2 foot thick layer of nomi ally compacted crushed rock ( 1-1/2 inch minus) be placed on the subgrade to provide a. firm base to compact the engineered backfill aga.ir►st. Engineered backfill should be placed, compacted and tested in lifts to a dry density of at least 98% T- 99 , or as approached by Geotechnical Engineer. Our reports pertain to the material tested/inspected only. Information contained herein is not to be reproduced, except in full, without prior authorization from this office. If there are any further questions regarding this matter, please do not hesitate to contact this office. Respectfully sobmitted, CARLSON TESTING I 'C Michael F. Schrieber, P.E. Vice President Geotechnical Engineer MS/cat cc: Sierra Pacific Development Inc . OTA)K Inc . Ci.ty of Tigard LS Henriksen Construction