Loading...
MARIELL ADDITION DENIED SUBDIVISION w+�w.rw.w�.warare...,.a��,....+�...e..mW� ....w-..`..�....,...........y....,...._...,..,�.�..�...a..�..m......,,....r �, �ARIELL�N Denied Subdivision -- CITY OF TIGAIW SANITARY Si;W h - 11AhIELL SU3DIVISIO Bids received Sen. 25, 1968 BUIJ hD 69 --� Item quantity PETTIT CONSTE,, CO. Unit Amount Unit Ame'knt Ucavati on and back- fill for newer pine . 200 cu.yd. 43.50 4700.00 44.00 0800.00 8" Concrete obwer kine in place 260 lir.ft. 2.60 650.00 3.00 780.00 6" Conorete serer nine in nlaoe 130 lin.ft . 2.50 326.00 2. 50 325.00 42"Dia. Stan4ard Manhole 1 Iii 230.00 230.00 250.00 250.00 Clean-out in nlaue 1 CO 85.00 85.OU 85.00 85.00 i 8"x 6" Y-branoh in place 4 ea. 8.00 32 .0 10.00 . 40.00 i 6" Tee in nlaos 4. ea. 8.00 32.00 7.00 £8.00 � i 6" Plug in place 4 ea. 2.00 8.00 2 .00 8.00 I r ravement out & repair 3 sq.yd. 10.00 30.00 Cog 24.00 i i bedding gravel in rlace 10 ou.yd . 5.00 50.00 4.00 40.00 Read gravel in place 5 o4.yd. 4.00 20.00 4.50 17.50 Performanoe bond Lump mum 21.00 24.00 Total 42 ,183.00 421421.50 i I FORM who-SO OREGON STATE SANITARY AUTHORITY STATE OFFICL BUILDING 1400 S. W. 6TH AVENUE PORTLAND 1. OREGON September 21, 1962. ,ar.. Elden W. Carter Con I.1.1ting Civil Engineer Oregon bank Building 319 S. W. Washington St. RAs S - Tigard Portland 4, Oregon Dear Mr. Carters Oe have recelvnd :and reviewed plans for ex�onsion of the Tigard seviage collection system with regard to the follmiingi 1. Hariell Sulxltvisiori. 2. S. W. Hunziker Road extension. As you have indicated the construction of the Hunzilaer Read project Will not incorporate any service additions but will merely reroute present flow. Appro,ml is boin,,, f;ranted with regard to the %riell. Svibdivision because of the positive steps which are being taken by the city of Ti.IT:grd to provide adequate treatment for thy+ collected w.nstes. It it our i:nderstanding that those projects will. be constrlieted according to the standard specifications of your office. Approval in herewith ,.ranted for both of these orojects subject to the following; provisions 1. Constr ction of the. proposed severs shall be in strict conform<.Ince to said approved pinns and specifications. No changes or deviations shall be made without the prior written approval of the Sanitary Authority. 2. The installation of Raid sewers shall comply fully with the rego- lotions of the State Board of Health and State Sanitary Ai.thority regarding the relative location or separation of water and sewer lines. Ree S - Tigard Page 2 September 21., 1962 .3. The constr fiction of said sewers shall be under the si!pervision of and shall be thoroi_i1ghly in:pnoted by the consulting engineer or his authorized representative who at the completion of the project shall certify in wr Itin.g to the A :thority that s,l ch nonstr .eti.or. v,--ie inspected b;r him and found to comply with the above regi.iirtinents. 4. Construction of the house or b,.ilding sewers which are to be con- nected to said sewers shall be of the same q ial ity and ,-ieto+ the same rrqArementr ,,with regard to materials, waterti Yhtnass and location. 5. No roof, &xftceo foundation, footing, or other gro,incl water drain lines shall.. be connected to rain sewer systn.,i. We are returning ore set of aach of these plans for your file. These bear our stamp of r)rovisional approval. Gnry truly rjurs, Harold S. U1.1tIcen Assistant Chief Sanitary Engineer JAJtc:h encl. cci City of Tigard cc: Washington County Health Dept. cel E. J. Verithersbxie Ei.DEN W. C. R'rER CONSULTING CIVIL ENGINEER OREGON BANK SLOG. 319 S.W.WASHINGTON ST. PORTLAND 4.OREGON 1961 Board of ConmiisE ionlars Tigard Sanitary Dictrict 8841 S.W. Con-mercial ,t . Sigurd 2%�20 Oregon Gentlemen: lieference is made to the requeet e�P i,:omae G. ziliott for an estimate of coel: of constrcet Ing a sanittary efwer on Cen- ter 2t . to serve Lots 1 tnrL 6, MAhIELL EL,bd.Lvision. The erttimate ix teased Lpon cLrrent prices of labor and mRt-- eriais L.nd i., CLbJE3Ct to _E'V1si0L" . i:stimattd Coit Licavation and backfill for sewer pipe , 16U o4.yd. 2 .00 per CLoyd. 300.00 8" Conertte serer pipe in place, 280 li.n.ft . m 2.0,0 per ft. 672' .00 e" Concre a sever pipe in pl&oe , 150 lin.ft . 2 .00 per ft . 300.00 ;'ianhole Ll place , 10tH 4 260.00 ee.. 600.00 8% 6" Y-brancii in place, 6 Y's 41, 6.00 erg. 36.00 b"" 1/8-bond in plaos, 6 bends a b.00 ew. 30.00 0 6" Insp. tee in place , b Tees w 5 .00 ea, 30.00 neetoring improvements 82 .U0 �y1,7 .U Dletriot overhead, ea4ineering, ekp.rvision, I65 0 292 .50 Total iistimated Cost (Caen to be advanr,ed to Tigard Zanit,sry Distriot) - - - - ;2924i; .bO Very trLly yours, iulden W. Carter, br4 i.Leer Tigard 6gnit4ry District In dupl.