Loading...
16150 UPPER BOONES FERRY ROAD BLDG C-1 f: A phi 15 MECHANICAL, REMO✓E C'OOR FRAME 4 REL Ir HT 1 CUT PRECA5T PANEL TO ' HVAC -DESIGN PROCEDURE REMO✓E WALLS SHOLN DOTTED AGCOMOC'ATE NEL u,- -- - - -- �- �� �� AGD NEW WALLS TO CREATE �� GOOFc FRAME t RELksHT O✓ER S INVENTORY REPORT F EACH UNIT .V A.0 ROOFTOP UNITS AND SUBMIT TO OWNER A CONDITIONS 1 1 / \ i' \ I,IEIU SPAGE5 SHOWN % '\ ` j 1 LIST TONNAGE OF EACH UNIT. (` 4 l `\ ) 1`\ 11 - - e (\ 2. LIST BY UNIT RECOMMENDED MA114TFNANCF OR REPAIR OF UNIT. I (�l�O 1}'(' r he O. O�O USE FXISTING H.V.A.C.. UNITS TO DESIGN MECHANICAL. H.V.A.0 SYSTEM PER PACTRUST •� _ -- ____.- -�__ __ _ _ - -- - DESIGN STANDARDS WHERE POSSIBLE. F— --____ CIPIVE I J Dri0RS /� �� — E UA_ 5 AT PROJECT DELIVERY, H.V A C CONTRACTOR SHALL SUBMIT A ZONE DIAGRAM FOR THE TENANT ---=-- --- -- ---- — --�I _ ) 6Tr- SPACE INCLUDING BOIH NEW/RENOVATED WORK AND SYSTEMS UNTOUCHED BY THE TENANT i - - I - I - I G IF+ - PANED MO'✓E ONE OR BOH ELECTRICAL PANELS w �. 220V IMPROVEMENT AS APPLICABLL THE ZONE DIAGRAM SHALL INCLUDE THE FOLLOWING: I - - ' I + hI4 I I TO ALLOW FOR 1_4 sER PAIR OF COORS I _ 1 DUCTING AND SIZES • I DISP I IY I ++ d18PLAY I � RAISE TRANSFO ER TO 9' AFF + I _ _ O(A8PLA� I 2 SUPPLY AND RETURN LOCATIONS AND CFM 1 I I u° 3 ROOF EQUIPMENT. SIZES AND LOCATIONS +_ __ ;�J + WAREHOUSE I v 4 THERMOSTAT LOCATIONS AND ZONE/UNIT ASSOCIATED THEREWITH 5 ANY SUPPLEMENTAL EXHAUST FANS OR SPECIAL SYSTEMS CE TER lL LL MUL ION I I \ 3'3'r 1'SLIDMG AK D TRACKITO HVAC DESIGN STANDARDS \� - - - - T Tr BE MOIlJTED CN FACE THE UJ 7LL \ I I, 5 TO BLOCKIlka A HED T THE WALL THE FOLLOWING ARE MINIMUM DESIGN STANDAI i \ - - SURFACE 43/8'F 415M PIECE TOMAT¢H I7. I DOOR TO C-O'r'ER OCKIt'a 1 1. 400 SQUARE FOOT PER TON + _ 2. NO ZONE SHALL BE LARGER THAN 1.000 SQUARE FEET. LARGE BUI_LPFN OR COMMON WALL TO WALL, TRACx r— • 1 CAPD i TROLLS LL4FLOOR GUIDES I ___— — -, t r- �•C,I AREAS ARE THE EXCEPTION ENTRYIRECEPT ( t I: - 1� -1C� N I �o+ M II W ` I I - � L - _ 3. SPECIALTY' ROOMS TO BE CONSIDERED ACCORDING TO EXTERIOR LOAD PLUS INTERIOR = I I � - - I - I r I USE CRITERIA AS PROVIDED TO PACTRUST BY TENANT PRIOR TO CONSTRUCTION. PRICING I - --` _ e RELOCATED I igREA - ��C �V SHOUT D RFFLFCT COST IN ADDITION TO THF BASIC: Al I OTMFNT OF 350 , QUARE FEET PFR p°0R L TON. COMPUTER/SERVER AND TELEPHONE ROOMS TO HAVE PROVISION FOR L.OV•: AMBIENT I -� I ,/ I / I + I + I a _ Q . z I i :, - OPERATION AND 24-HOUR USE !l) I / __. ._ �/ - - I 1h I I CA J r,•� I - � -- I ��`♦�- �AL ICsN ClRC 4. UNITS. LENNOX TRANS, YORK AND CARRIER i +� Boa v~ 5. UNIT PLACEMENT 24' MINIMUM TO CENTER FROM ROOF EDGE. MULTI-PLACED UNITS I � I ' I � SHOULD BE SYMMETRICALLY IN A LINE BASED ON STRUCTURAL CALCULATIONS BY ENGINEER. i I - - i -- -- - J" i OFFICE PEN OFFICE I � � . — • I jos �� � �—�-� (GROUP MACKENZIEI 6 CURBS 14" CURBS ASSEMBLED AND LEVELED TO ROOF. ANCHORED TO STRUCTURAL_ MEMBERS BELOW ROOFING. i , I 5 SALES OFFICE A. PROFESSIONALLY RC)OFED IN ALL CURBS AND PENETRATIONS BY PACTRUST SELECTEE 1 _ - - - -- -- - � i -- � ul - � - -♦ -__T� t ROOFER. I �_ B. UNIT MUST BE LEVEL, SEALED WITH NO AIR LEAKS AND COUNTER FLASHED C. CONDENSATE MUST BE TRAPPED AT UNIT. i �- - ; OFFICE • 4 • L I I T I IL 7 SEISMICALLY ATTACH UNIT TO CURB IN CODE-APPROVED FASHION. i - -; �._- - I ion I ROOF JACKS FOR. L^`"'VOLT"GE AND GAS MUST BE ROOFED IN '.T THE SAME TIME V'ITH U 1.J V Y 11 1 ^'O C PATCH. ROOF AC AL E CURED WITH SEALANT AND O UNIT CURB. COLD ATCH 00 JACKS SHALL B SECURED I ,ir \ -_L- �p ( a` STAINLESS PIPE CLAMP. GAS PIPE ON INTERIOR OF BUILDING ONLY. DO NOT ISOLATE A l -- - - - _ -J I -