Loading...
10340 SW NIMBUS AVENUE .r N �e ADDRESS: ;r 1)?)Jq 0 4 f 6u') Lk lawg i ! r r t i:\records\microflm\targets\buildirig.oc^ r. millomw Page • r UnHIrKI Sewaape Agency 1 of 4 Source Control Sakes Department 400 E.Main,Fuile 200 Hllbboro,O;e(�on 91123 (603)6934541 (SM)648-0614FAX INDUSTRIAL WASTE DISCHARGE PERMIT a Duty to Comply The permittee must comply with all conditions of t`tis permit. Failure to comply with the requirements of this permit may be grounds for administrative action or enforcemerr!proceet.:.�,,Qs including civil or criminal 1 penalties, injunctive relief, and summary abatements. 1 1.1a Applicant Business Name Uu1.11 1.,ocl( Partition Systema Location Code (permit#):111-073-1 1.1b Business or Industrial Park Name troll Business tante► SIC Number: 3499 1.2 Address of Premises Discharging Wastewater USA Treatment Plant: Durham + Stree, 10340 SW Nimbu© Ave. Ste. N-D City Tiv„rd State tuk Zip Code °!7,?.3 l 1.3 Assessor's Map and Tax Lot Number Is I. 34AA 1800 1.4a Mailing Address (If different than above) Street tiAr4i, City State Zip Code 1.4b Billing Ado,ass Street SAME jCity State Zip Code 1.5 Persons to be Contacted About this Permit Primary Business Official (Name) Cl,, Gr.mt Title I'r,;,sideent Tel. 62U-9494 Alternate Business Official (Name) Title Tel Billing Information Contact Person(Name) SAME' Title Tel. Pretreatment System Contact Person (Name) `;AW'. Title Tel. 1.6 Effective Date: A4)„ St 5 /q qt� Expiration Date: 5/1 /90 Monitoring Status Q Non-Monitoring Status E 1.7 Authorization: The above-named applicant is authorized to discharge industrial wastewater to the public sanitaty sewer system in compliance with the Agency's appropriate Resolutions and Orders, and , pplicable provisions of N Federal and Stats law or regulation, and in accordance with discharge point(s), effluent limitations, monitoring requirements and all other conditions set forth herein. This permit is granted in accordance with the application filed in the office of the Unified Sewerage Agency Source Control Services by the permittee, and in conformity with plans, specifi ations and data submitted to the Agency by the permittee, as well as payment of the following fees and charges. In no case shall this permit be transferred to another owner, partnership or corporation without prior written notification to the 'Initied Sewerage Agency Source Control Services. In the event ownership of the permitted industry changes,the owner of this permit shall provide a copy of the existing Industrial Waste Discharge Permit to the new owner or operator. 1.8 Owner's Representative Print Name Clem Gram. i itle Preoident Signature _.- Date j 1A Agency's Representative Print Name Steve Anderson Title `source Control Investigator Signature Date Nevlsed 12191 Whiles USA,Green Industry,Yellr City.Pink-Accountinq,Goldenrod WOL Form 1281-16 1 �r R *� i'' '`✓'•fiia, .,'��W+9.n u , Il�i�; 'G.'C�►� y !�"� 6.y�3 r �,.�X,q{ vv.. . .. .a y „qi,r.J l ti S fr •.r. � � i1r 1 t r Dlecharge Limitations and Sampling Requirements II Any inductrlal user subject to reporting requirements shall maintain records of all Information resulting from any monllorb,j activities!40 CFR 403.12(o)). Such records shall be Included for all samples: • The date,exact plata, method and time of sampling,and the name or names of all twrsons taking the samples. • The dates the analyses were performed. • Who performed the analyses. The analytical methods/techniques uses. • The results;of such analyses. r • Calibration log for pH and flow meters. Any industrial user subjact to the reporting requirements established In Vets Soctlpn is required to retain for a minimum Of 3 years any records o! monitoring activities and results. If pretreatment standard viotatlons are riot corrected within a reasonable period or time as determined by the Agency, i or agreed upon previously,or If there appears to be Indications of repetition Lf the vinlatiuns, a Notice of Civil Penalties may be issued as doscri'oed In Agency rules. The Agency may seek or assess the maximum civil or criminal penalties of at least$1,000 per day pdr violation of pretreatmentstandards,and any applicable compliance schedule. Compli• ante schedules may not extend the compliance date beyond any applicable federal deadlines, tr,; Notes: ^` Total Toxic Organics(Tro)is the summation of all values greater than 0.01 rng/L for each of the toxic organics specified In the Priority Pollutant List in the Pretreatment Rules and Regulations. i All metals analysis shall be for total metals, unless otherwise specified. The Agency may redu�v or Increase the frequency of sampling based on the analytical results submitted. 24 hour composite sample - A sample representative of dally dlscharge:Flow•proportioned,or;a minimum of 1 sample per hour of equal volumes collected over a 24 hour period. Samples may be composited and preserved according to 40 CFR Part 136 and amendment.,. An ideal 24 hour composite sample Volume'shall be 4 liters. A"Grab"sample Is an Indivlduai sampie collected in less than 15 minutes,withoui regard for flow or time, The sampling shall be representative of daily operations. • A minimum of tour grab samples must be,used for pH Cyanide Total phenols Oil and grease Sulfide Volatile organics • 24-hc:.'r flow-proportional composite sampling Shall be used for all other constituents • Sampling and analysis shall be performed In accordance with 40 GFR Part 136, and amendments. Cyanide -Four discrete grab samples shall be collected over the operating day. The samples ehall be collected from a point after the Cyanide Destruct process,but,prior to mixing with other processes or domestic wastestreams. each aliquot shall not be les:•,then 100 ml and shall be collerled and cornpos'rted Into a larger container which has been preserved with sodium hydroxide to Insure sample Integrity. i pH-Provide a daily summary of the ph strip chart record,noting the excursions out of pH range greater than 15 1 minutes,and noting the pH at the peak of the spike(high or low). l Oil and grease- Four discrete grab samples shall be collected over the operating day The arab samples shall be collected in glass containers fitted with a ground glass stopper and preserved In accordance wilt,40 CFR Part 136 and amendments. All samples shall be C1bllerled at ths+sampling location designated undar the Sampling Site Lor;atlon section of this permit. s,w„m.�,•,,.,,,..+w+,,,,,,..,........-....._. ......o....+.",......,•,.....,.....,,....."..•.o,..Y�++nwwsow+,w.+n..... ..,.,_ ..._......_...._.._�.._..•,.-.,,w...,., .....•,....e.. ..-.ro...w.n�,-".+.o..nw,. �Y�wwwar"-•.--*""+g4"�,".'.'�i7�-u�"!`,'r` ',"!!('i�;:^`w"'.'__d_._..�....w.�.----,-- :.T^.,,�snwr:u—�A'c,.,., k, S Page ' ?_ of 4 UnlBed Sawwpw Agency Source Control Servk;ef Department 400 E.Main,Suite 200 Hllbboro.Oregon 97123 111--073-1 (6(13)693-0641 Dual Lock Partition Systr_ma3 (,,%3)648E814FAX Location Ccde(Permit#): Fees Permit Remit Fees to: Connection Additional Capacity 0 Miscellaneous Total rD Reporting Requirements i 2.1 a The permittee is required to submit testing results of wastewater sampling and appropriate meter readings to Unified Se,werane Agency (on approved forms) no later than the 10th of the month following discharge. Specific sampling criteria and specific items to be sampled are listed in the Sampling Requirements Section, below and on back of Page 2. 2.1b The permittee is required to submit testing results of wastewater sampling on a semi annual basis. Waste water is to'ie sampled during the months of June and December. Specific sampling criteria is identified in Sampling Pi,quirements Section. Flow meter and pl-I meter readings may still be required monthly. If required,they are due at the Agency no later than the 10th of the month following testing (or discharge). 2.2 Report any significant changes (permanent or temporary)to the premises or operations that significantly change the quality or volume of the wastewater discharge or deviates from the terms and conditions under which this permit is granted. 2.3 If sampling performed by an Industrial User indicates permit violation,the user shall notify the Agency within 24 hours of becoming aware of the violation. The user shall also repeat the sampling and analysis and 1 submit the results of the repeat analysis to the Agency within 30 days after becoming aware of the violation. Ili Additional Reports The following reports are also due prior to the dates specified. If no date specified, report request does not apply. 2.4 Report on compliance (ROC) due within 90 days of start-up. This report is necessar)VR determine the immediate start-up compliance status (40 CFR 403.12(d)). Due no later than: 2.5 Solvent, Toxic, Organic Management Plan, (STOMP/TOMP) due by the following date: _ NA This plan is due to assess the uses and disposal procedures relating to solvents and toxics used in the industrial processes (a federal EPA requirement). 2.6 Accidental Spill Plan (SLUG CONTROL.)the following report is due: —_._______-- This plan is required to assess the emergency planning of the permittee In case of a chemical spill in their facility. The report must address the steps the permittee will take to keep spilled or unused chemicals out of the sanitary':;torm sewers, either by intentional or accidental release (40 CFR 403.6 (f)). 2.7 Hazardous Waste Reporting Whenever the EPA publishes new RCRA rules identifying additional hazard- ous wastes,the permittee must notify the Agency, EPA RGRA Director, and Oregon State Hazardous Wastu Director if any of these wastes are discharged to the Agency's treatment system. The notification must occur within 90 days of the effective date of the published regulation (a federal FPA requirement). Owner/Representative Signature Agency Signature �. ReWmA I:i9t white•USA,Green Industry,Yellow Clty,Pink Accounting.Goldenrod WOl corm 1:91 t7 FO � r u e Page UnMed 13ewerpe Agency 3 of 4 f Source Control S*Mcm Department f 400 E.Main,Sulte 200 Hillsboro,Oregon 97123 (503)693.4641 (501)6M-M74FAX Dual Lock Partition Systema Location Code(f )rmit#): 111-073-1 Discharge Limitations and Sampling Requirements IThe following monitoring requirements shall apply to the wastewater discharge from the permitted facility: Parameter Storet Units' Daily Max. Monthly Avg. Sampling rreq. Type of Sample I See Note 1 Meter Reading � pH Mux 400 5.u. 10.0 NA �. pH Min 401 S.U. 6.5 NA See Note 1 Meter Reeding CN(T) 720 Ir :.2 0.65 Biannual Grab 1027 * 0.11 0.07 Biannual 24 HK Composite Cd (T) 1027 * L.77 1.71 Biannual 24 HR Composite Cr( T� 1042 * 3.38 z .07 Biannual Cu24 HR Composite Cu(T) 1051 * 0.69 0.43 Biannual 24 HR Composite 9.(T) 1067 * 1.70 2.38 Biannual 24 HR Ccnt^osite N N1077 Or 0.43 0.24 Biannual 24 HR Composite Ag(T) ::n(T) 1092 * 2.61 1.48 biannual 24 HR Compooite Flow 5005U GPD 1750 1250 Daily Meter Reading TTO 90001 * 2.13 - Covered by TOMP Aye icabIt jtjLulatioliu: 40 �'7K Parts 403 and 433.17 Special R uir.ements: 1. I<ecord pH measuroments every 30 minutes while (iischarging. if any pH measurement in out of range, record pti measurements every 5 minutes until the pH 1' I—tween 6.5 and 10.0. 2. All sampling and testing will be pertorme.d as per 40 CFR parr 136. 3. Submit daily flow meter readings and pH summary on monthly self-monitoring reports (SMR). 4. Discharge of iron phosphate procoat. tank will be allowed only upon prior approval by the Age,icy. 'mg/L,unless otherwise specified Owner/Representative Signature Agency Signature nevlsed 1,'/91 White USA.Green-Industry,Yellow-City,Pink-Accounting,Goldenrod•WOL Form 1291-18 t'tP j c, r t Page ,1 Unload e�k,•RGy 'f O f 4 Source Control;eMces Deportment 400 E."oln,Su"200 Hlkboro,Oregon 97123 (603)693 d541 - (b03)64B-B870 FAX Sample Site Location Location of sample sites indicated in the drawing are the official Agency and industrial sample collection loca- tions, including the cyanide sampling point, if required. All samples tested for permit constituents must be obtained from these sites. Business Name Dual sock .P rtttiQn Systems _ U,Q4 Permit#/Location Code ...1 t 1-n73-1 1 Imp i (� I {--�, VQ u I t Somflc. l 4..-...I......�.-_ �.... y Process T vIKS � 1 MQn4fc4cfu r i n 9 Fain4 t Huef h f t To <ti�ln/ 111� �s Mariner RtK.c�f1 r't Owner,'Representative`-signature Agency Signature Revised IA19I White US rn Industry,Yellow•City,Pink Accuunling,Goldenrod Wr)L Form 1291-19 r i