Loading...
Plans iter S_ e-;CO —Cx,t.A? I Li Aoc. Sw 72 14c, ` �. . 81 cc < C elm/ 51A 3"x'' 8tr2e bom.. \ 1 \\p0uhle 4)1.41" a'/0(G7*'X '4y" A.iiy/e lVOA Ofi C� Ty�pp Typ/ a Y �--- .3f"71-A frea d As\se;544rc i3 race To s-f`oc±o -e. Wecdei' Detail for Modine Power Vented Propeller Unit Model PDP400 Weight=418 lbs. Project: Gerber-Gas Heater Hanging Detail Location: 14200 SW 72nd Scale: Not To Scale Plan Sheet Drawn By: Date: 01/16/2017 'Rev. M-1 4.9ODINE AccuSpec V4.8c PDP MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 PDP 400 A E 01 30 S B A N 1,2,3- Product Type PDP— Power Vented Propeller Unit 4,5,6- Furnace Input Rating 400- 400,000 Btu/hr Input 7- Heat Exchanger Type A-Aluminized Steel Heat Exchanger and Burner 8- Pilot Ignition E - Intermittent Pilot Ignition 9,10- Motor and Drive Code(Power Code) 11,12-Control Code Type 30 - Single-Stage, Intermittent Pilot Ignition, Natural 13—Fan Guard Type S - Standard Fan Guard 14—Development Sequence B- Current 15— Future A—For Future Use 16—Factory Installed Option N - None 4:013DINE AccuSpec V4.8c GENERAL PERFORMANCE DATA DESIGN c�RTIF�,.'o® CERTIFIED General Performance Data Model PDP400 At 0' Elevation Btu/Hr. Input 400,000 Btu/Hr. Output 328,000 Entering Airflow(CFM) 5440 Outlet Velocity 1016 Air Temp. Rise (°F) 56 Mounting Height (Max Ft.)1 19 Heat Throw(Max. Mtg. Ft.)2 69 Unit Total Power(Amps) 5.58 at 230V (Operating Current on Transformer Line Side) As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 400,000 Btu/Hr. Output 328,000 Configured Air Temp Rise (°F) 56 Motor Data Horse Power RPM Type Motor Amps Clearances to Combustibles3 Top 5" Bottom 12" Top of Power Exhauster 3" Side (Access and Non-Access) 1" Rear 6" 1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without deflector hoods. 2 Heat Throws are calculated at 65°F ambient with a 56°F air temperature rise with the unit mounted at a maximum mounting height of 19 feet. 3 Provide sufficient room around the heater to allow for proper combustion and operation of the fan. Free area around the heater must not be less than 1-1/2 times the discharge area of the unit. whiOPINE AccuSpec V4.8c DIMENSIONS - UNIT Model PDP Dimensions �M A—► -.0—C-1..- 1 -4—H—=1 4—FSI I I - -4-DD I ~ W --x��CC ��K I I I AA FilIM f E e Jil I F 1 1 Jll o _LL SibENIVE BBf .....3tt .. EE I ►� D(OPENING) �—L - (MIN.DISTANCE TO WALL) Model Size PDP400 Dimensions (inches) A 40 W 5 B 40.25 X 16 _ C25 AA 9 D 37.5 BB 7.25 E 24 CC N/A F N/A DD 6.8125 _ G 7.5 EE 32.875 H 36.375 _ LL 40.5 J (Round)1 6 K(Mtg Holes)2 3/8-16 Gas Connection4 3/4 L3 44.1875 Fan Diameter 24 M 38.1875 A..rox. Shipping Weight 418 lbs. 1 For some models, this is the dimension of the vent transition outlet supplied with unit. 2 PDP150 through PDP 300 have 2 holes and the level hanging adjustment feature. PDP 350 through PDP 400 have 4 holes. 3 Dimension equals overall plus 6". 4 For natural gas; may vary depending on control availability. { � E AccuSpec V4.8c PTP MODEL NOMENCLATURE 1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16 PTP 400 S S 01 11 S B A N 1,2,3- Product Type PTP - Power Vented Propeller Unit 4,5,6 - Furnace Input Rating 400-400,000 Btu/hr Input 7- Heat Exchanger Type S - Stainless Steel Heat Exchanger and Aluminized Steel Burner 8- Pilot Ignition S— Direct Spark Ignition 9,10- Motor and Drive Code(Power Code) 01 - 115V motor&230/115 Transformer 1 Phase 11,12—Gas and Valve/Ignition Control Type(Control Code) 11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry 13—Fan Guard Type S - Standard Fan Guard 14—Development Sequence B - Current 15— Future A—For Future Use 16—Factory Installed Option N - None 4.7013DIIIIE AccuSpec V4.8c GENERAL PERFORMANCE DATA c us ,,moo Intertek General Performance Data Model PTP 400 At 0' Elevation Btu/Hr. Input 400,000 Btu/Hr. Output 328,000 Entering Airflow(CFM) 5995 Outlet Velocity 851 Air Temp. Rise (°F) 51 Mounting Height (Max Ft.)1 21 Heat Throw (Max. Mtg. Ft.)2 74 Unit Total Power(Amps) 5.23 at 230V (Operating Current on Transformer Line Side) As Configured at 0-2000 Ft. Elevation Btu/Hr. Input 400,000 Btu/Hr. Output 328,000 Configured Air Temp Rise (°F) 51 Motor Data Horse Power RPM Type Motor Amps at 115V Clearances to Combustibles Top and Bottom 6" Vent/Combustion Air Connector 6" Access Side 6" Non-Access Side 6" Rear 18" 1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit. 2 Heat Throws are calculated at 65°F ambient with a 51°F air temperature rise with the unit mounted at a maximum mounting height of 21 feet. f v ?ODIrvE AccuSpec V4.8c DIMENSIONS - UNIT Model PTP Dimensions G A 4 MOUNTING _ I RHOLES HTIUPOWER VTERADJUSTABLE S _ _— VENTPIPE ENCONNECION LOUVERS •} r , / / N !1I'.._ fj/// , \`�` i ® ACCESS PANEL •E -_-__ :II1�1��I I / B • . . _i i GAS % CONNECTION OPENING l)II' I / • tTM.I.T.,;/;Vi / I IIIIII�L� \� I —sTSTAT / . \�= j . ��'— CONNECTION — I ELECTRICAL Fes— D OPENING CONNECTION C '. I" MOTOR CORD 1. -.—H STRAIN RELIEF M(APPROX) O(MIN DIST TO WALL) Model Size PTP400 Dimensions (inches) A 42.53 I 4.5 B 39.56 J 10.84 C 22.05 M 34.83 D 29.52 Q 2 46.83 E 37.68 R 3.56 F 23.58 S 14.9 G (Mounting Holes)1 3/8-16 T 10 H 8.37 U 20.53 Gas Connection4 3/4 Fan Diameter 24 Vent Connection Size 6 A..rox. Shi.sing Weight 320 lbs. 1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod. 2 Dimension equals overall plus 12". ' `tel A, 74 e w B °3 ' ^t ua a sa+ "' 120® SW 7v2nd Ave `` t 4 t v. 1 l .Y r'' " ip Go' 'gle Earth feet 400 A meters 100