Plans iter S_ e-;CO —Cx,t.A?
I Li Aoc. Sw 72 14c,
` �. . 81 cc
< C elm/ 51A
3"x'' 8tr2e bom.. \ 1 \\p0uhle 4)1.41" a'/0(G7*'X '4y" A.iiy/e lVOA Ofi C�
Ty�pp
Typ/ a Y �--- .3f"71-A frea d
As\se;544rc i3 race
To s-f`oc±o -e.
Wecdei'
Detail for Modine Power Vented Propeller Unit
Model PDP400
Weight=418 lbs.
Project: Gerber-Gas Heater Hanging Detail
Location: 14200 SW 72nd
Scale: Not To Scale Plan Sheet
Drawn By: Date: 01/16/2017 'Rev. M-1
4.9ODINE
AccuSpec V4.8c
PDP MODEL NOMENCLATURE
1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16
PDP 400 A E 01 30 S B A N
1,2,3- Product Type
PDP— Power Vented Propeller Unit
4,5,6- Furnace Input Rating
400- 400,000 Btu/hr Input
7- Heat Exchanger Type
A-Aluminized Steel Heat Exchanger and Burner
8- Pilot Ignition
E - Intermittent Pilot Ignition
9,10- Motor and Drive Code(Power Code)
11,12-Control Code Type
30 - Single-Stage, Intermittent Pilot Ignition, Natural
13—Fan Guard Type
S - Standard Fan Guard
14—Development Sequence
B- Current
15— Future
A—For Future Use
16—Factory Installed Option
N - None
4:013DINE
AccuSpec V4.8c
GENERAL PERFORMANCE DATA
DESIGN
c�RTIF�,.'o® CERTIFIED
General Performance Data
Model PDP400
At 0' Elevation
Btu/Hr. Input 400,000
Btu/Hr. Output 328,000
Entering Airflow(CFM) 5440
Outlet Velocity 1016
Air Temp. Rise (°F) 56
Mounting Height (Max Ft.)1 19
Heat Throw(Max. Mtg. Ft.)2 69
Unit Total Power(Amps) 5.58 at 230V (Operating Current on Transformer Line Side)
As Configured at 0-2000 Ft. Elevation
Btu/Hr. Input 400,000
Btu/Hr. Output 328,000
Configured Air Temp Rise (°F) 56
Motor Data
Horse Power
RPM
Type
Motor Amps
Clearances to Combustibles3
Top 5"
Bottom 12"
Top of Power Exhauster 3"
Side (Access and Non-Access) 1"
Rear 6"
1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit, and without
deflector hoods.
2 Heat Throws are calculated at 65°F ambient with a 56°F air temperature rise with the unit mounted at a
maximum mounting height of 19 feet.
3 Provide sufficient room around the heater to allow for proper combustion and operation of the fan. Free area
around the heater must not be less than 1-1/2 times the discharge area of the unit.
whiOPINE
AccuSpec V4.8c
DIMENSIONS - UNIT
Model PDP Dimensions
�M
A—► -.0—C-1..-
1
-4—H—=1 4—FSI
I I - -4-DD
I ~ W --x��CC
��K I I I
AA FilIM
f E e Jil
I F 1 1 Jll
o _LL
SibENIVE BBf .....3tt .. EE
I ►� D(OPENING) �—L -
(MIN.DISTANCE TO WALL)
Model Size PDP400
Dimensions (inches)
A 40 W 5
B 40.25 X 16 _
C25 AA 9
D 37.5 BB 7.25
E 24 CC N/A
F N/A DD 6.8125 _
G 7.5 EE 32.875
H 36.375 _ LL 40.5
J (Round)1 6
K(Mtg Holes)2 3/8-16 Gas Connection4 3/4
L3 44.1875 Fan Diameter 24
M 38.1875 A..rox. Shipping Weight 418 lbs.
1 For some models, this is the dimension of the vent transition outlet supplied with unit.
2 PDP150 through PDP 300 have 2 holes and the level hanging adjustment feature. PDP 350 through PDP 400
have 4 holes.
3 Dimension equals overall plus 6".
4 For natural gas; may vary depending on control availability.
{
� E
AccuSpec V4.8c
PTP MODEL NOMENCLATURE
1,2,3 4,5,6 7 8 9,10 11,12 13 14 15 16
PTP 400 S S 01 11 S B A N
1,2,3- Product Type
PTP - Power Vented Propeller Unit
4,5,6 - Furnace Input Rating
400-400,000 Btu/hr Input
7- Heat Exchanger Type
S - Stainless Steel Heat Exchanger and Aluminized Steel Burner
8- Pilot Ignition
S— Direct Spark Ignition
9,10- Motor and Drive Code(Power Code)
01 - 115V motor&230/115 Transformer 1 Phase
11,12—Gas and Valve/Ignition Control Type(Control Code)
11 - Natural, Single Stage, Direct Spark Ignition, 100% Shut-Off with Continuous Retry
13—Fan Guard Type
S - Standard Fan Guard
14—Development Sequence
B - Current
15— Future
A—For Future Use
16—Factory Installed Option
N - None
4.7013DIIIIE
AccuSpec V4.8c
GENERAL PERFORMANCE DATA
c us
,,moo
Intertek
General Performance Data
Model PTP 400
At 0' Elevation
Btu/Hr. Input 400,000
Btu/Hr. Output 328,000
Entering Airflow(CFM) 5995
Outlet Velocity 851
Air Temp. Rise (°F) 51
Mounting Height (Max Ft.)1 21
Heat Throw (Max. Mtg. Ft.)2 74
Unit Total Power(Amps) 5.23 at 230V (Operating Current on Transformer Line Side)
As Configured at 0-2000 Ft. Elevation
Btu/Hr. Input 400,000
Btu/Hr. Output 328,000
Configured Air Temp Rise (°F) 51
Motor Data
Horse Power
RPM
Type
Motor Amps at 115V
Clearances to Combustibles
Top and Bottom 6"
Vent/Combustion Air Connector 6"
Access Side 6"
Non-Access Side 6"
Rear 18"
1 At 65°F ambient and unit fired at full-rated input. Mounting height as measured from bottom of unit.
2 Heat Throws are calculated at 65°F ambient with a 51°F air temperature rise with the unit mounted at a maximum mounting
height of 21 feet.
f v
?ODIrvE
AccuSpec V4.8c
DIMENSIONS - UNIT
Model PTP Dimensions
G A
4 MOUNTING _
I
RHOLES HTIUPOWER VTERADJUSTABLE S _ _— VENTPIPE ENCONNECION
LOUVERS •} r ,
/ / N
!1I'.._ fj/// , \`�` i ® ACCESS PANEL
•E -_-__ :II1�1��I I / B • . . _i i GAS
% CONNECTION
OPENING l)II' I
/ •
tTM.I.T.,;/;Vi
/ I
IIIIII�L� \� I —sTSTAT
/ . \�= j . ��'— CONNECTION
— I ELECTRICAL
Fes— D OPENING CONNECTION
C '. I" MOTOR CORD
1. -.—H STRAIN RELIEF
M(APPROX)
O(MIN DIST TO WALL)
Model Size PTP400
Dimensions (inches)
A 42.53 I 4.5
B 39.56 J 10.84
C 22.05 M 34.83
D 29.52 Q 2 46.83
E 37.68 R 3.56
F 23.58 S 14.9
G (Mounting Holes)1 3/8-16 T 10
H 8.37 U 20.53
Gas Connection4 3/4
Fan Diameter 24
Vent Connection Size 6
A..rox. Shi.sing Weight 320 lbs.
1 All models have 4 holes for mounting. Listed is the hole diameter and threads per inch to accept threaded rod.
2 Dimension equals overall plus 12".
' `tel
A,
74
e w
B °3 '
^t ua
a sa+ "' 120® SW 7v2nd Ave ``
t
4
t v. 1
l .Y r'' " ip
Go' 'gle Earth feet 400 A
meters 100