Loading...
9900 SW GREENBURG ROAD STE 100 V PROP05ED PROJECT _ EXISTING SUITE 100 BLDG. -- -- - ENTRY Nz -BRACING TO 5TRUCTl1RE W s 10' INTERVALS, MIN. / -EXISTING STRUCTURE BATT INSUL. w 51M, ONLY EXISTING ACOUSTICAL TILE � �- 5EE PLAN FOR LOCATIONS CEILING ASSEMBLYsig '-� K' 2 1/2" METAL STUDS e 24"o.c. - - a n I �J o IN5UL. TO CEILING- '`> EXISTING SUSPENDED A. SI W/ 5/8" GYP, BD. AS REQUIRED ACOUSTICAL TILE CEILING E DE ___­2 1/2" METAL STUDS m 24"o.c. DG. - - l I I BLDG. .r EXIT I L cXIT TYPE "X" GYP. BD. / EA. SIDE 4" RUBBER BASE �-4" RU55ER BASE CARPET OR SHEET VINI L PER PLAN 1, ..�^ l I -� ,......... • - - - -- --- I -- n n n BLDG. BLDG. 4 TYP. DEMISING PARTITION 3 TYR TENANT PARTITION -- - -- - -- -- - - - - ENTRY ENTRY A-1 SCALE: 1 1/2" = 1'-0" A-� SCALE; 1 1/2" = 1'-0" G= UT NOTE: DEMISING OF THIS TENANT NOTE: DO NOT SUPPORT WALL BY T-BAR CEILING. Olga or SUITE EXIST. NO CHANGES ANTICIPATED WITHIN THIS SCOPE OF PROJECT. 6Pr' ssolppdq ......!. Ma1o�:oi,��F�1 e8s {' ............................ ,_.,�, 'ON llwd3d Q10$eP'9ByYOM 01ij AtuO J0J ...........p9nolddH Ar,leuoil!puoO . ................. ..... .................,................penolddy ad.1011 :JO A113 GENERAL NOTES & SPECIFICATIONS - I Tire CONTRACT DOCUMENTS for this project are comprised of (1) each blueline I �P print SHEETS A-I through A dated March 6, 2001, and includes the • BLDCs. Following SPECIFICATIONS. � EXIT The 5PEGIFICATION5 and DRAWINGS reference existing tenant Improvements, I _ - details, and materials that are understood to be "tenant standards" and as (- such are to be duplicated or matched for this project, except as EXISTING SUITE 100: specifically modified herein. 2 LOCATION AT FIRST FLOOR: NORTH WiNG _ NORTH I. Work being shown and specified in these Contract Documents Is Intended 18. Contractor to perform demolition, removal and alteration work as si-town 28. Provide painting and prep work in accordance with established standards N.T.S. to coordinate with existing field conditions, Dimensions take precedent with due care, including shoring, bracing, etc., shall take care to protect of COLUMBIA BUSINESS CENTER, and per "Painting Specification Guide" as established A-1 over scale. Where discrepancies occur between Contract Documents and Field all Items specirically mentioned or Implied as to remain or to be by Oregon Council Painting and Decorating Contractors of America (PDGA), Materials: LOCATION: THESE PROPOSED TENANT IMPROVEMENTS ARE Tr BECOME PART OF THE GENERAL LEASEHOLD conditions within the description of work addressed herein, the Contractor relocated, shall execute the Mork in a careful and orderly manner, with the Provide "tenant standard" paint materials including finish coat products that are IMPROVEMENTS LOCATED WITHIN EXISTING TENANT SUITE 100 OCCUPYING APPROXIMATELY 2,416.88 UE,ABLE SQUARE shall request a clarification from Owner Tenant, and Designer prior to least possible disturbance to public and to occupants of building. compatible with prime coat products. In addition, Contractor to provide FEET AT THE GROUND FLOOR OF EXISTING BUILDING: COLUMBIA BUSINESS CENTER: V2100 S.W. GREENF_URG ROAD, proceeding with the work labeled touch-up paint, and store as directed by Owner and tenant. Gypsum SUITE 100, PORTLAND OR. 9122 . T1-;E EXISTING BUILDING 15 TWO 5TORIE5 IN HEIGHT, CONSTRUCTION TYPE: v-N, FULLY 19. Where alterations occur, or new and old work join, Contractor to cut, wallboard: stippled alkyd enamel, finish: roller apply, prime coat latex SPRINKLED, OCCUPANCY: GROUP B, CONTINUED TENANT U5E: ADMINISTRATIVE AND MANAGEMENT OFFI_:ES, THE SCOPE 2. Contractor and Subcontractors shall carefully examine the existing site remove, patch, repair or refinish adjacent surfaces to the extent required emulsior. primer sealer, second coat alkyd enamel, finish coat roller OF THIS PROJECT DOES NOT REQUIRE CHANGE OF OCCUPANCY. and Contract Documents. Errors and omissions in the plans and by the involved conditions to create an appearance Equal to, or better ti-or applied alkyd enamel, eggshell semi-gloss, unless otherwise directed by specifications shall be called to the attention of the Designer prior to as existed prior to commencing the work, finish new and adjacent existing Owner. Appllcatlon: Paint sub-contractor to examine all surfaces and SCOPE OF PROJECT- PROPOSED REMODEL INCLUDES L)EMOL.ITION OF SELECT EXISTING NON-5-11RUCTURAL construction so that An addenda or change order, if necessary, may be surfaces as specified for new work, and clean exlsting surfaces of dirt, conditions prior to performing work and notify Contractor of conditions TENANT STANDARD PARTITIONS CR PORTIONS THEREOF, REMOVAL OF EXISTING DOORS AND DOOR FRAMES AN.: RELITE5 (SOME issued. Failure to do so on the part of the Contractor does not relieve grease, loose paint, etc, before refinishing. Materials and workmanship detrimental to proper and timely completion of work, perform preparation FOR REUSE IN ALTERNATE LOCATIONS), CONSTRUCTION OF NEW TENANT STANDARD NON-STRUCTURAL f--ARTITIONS TO him of the responsibility to provide a correct and finished product. employed in alterations, unless otherwise shown or specified, shall conform and cleaning procedures in strict compliance with manufacturer's CEILING, INSTALLATION OF NEW (--A5EWORK, RELOCATION OF EXISTING PLUMBING: (( ) SINK, TO AN ADJACENT LOCATION) to that of the original work and all alteration work shall be performed by recommendations for each substrate, and apply painting and Finish materials CONSTRUCTION OF (3) NEW OFFICES UTILIZING TENANT STANDARD PARTITIONS, DOORS AND DOOR FRAi'11=5, MINOR 3. All new construction shall be performed iii accordance with state and the respective trades which normally perform the particular items of work in accordance with product manufacturer's directions using applicators and MODIFICATION OF EXISTING POWER, SIGNAL AND DATA SERVICES RELOCATION OF EXISTING ''4" x 48" FLUORESCENT NT local codes and to conform to rules and regulations of all departments and Materials which are removed shall be considered reuseable unless released procedures best suited for the material and surfaces to which applied. LODIFIC TION WITHIN EXISTING SUSPENDED ACOUSTICAL LAY-IN CEILING AND ALTERATION T 2 Xf TI i;.vA.E . Y T M authorities haven jurisdiction thereof includin Americans With b Owner. Contractor is to take all necessary precautions in the removal SaFet Precautions: Provicie complete safety measures at all ,Imes for O EXISTING NG S S E ' g j g y y p y p y TO EXTENT OF RELOCATION OF SOME EXISTING DUCT WORK AND SUPPLY AND RETURN DIFFUSERS, AS MAY BE REQUIRED Disabilities Act. Existing building entrance, parking, path of travel, of material to Insure the least amount of damage. Materials which are protection of persons, materials and locations against hazards related to TO PROVIDE STANDARD AND CUSTOMARY H.vA.G. CONDITIONS TO FRO OS RECONFIGURED elevators, drinking fountains, rest rooms, signage and public access areas removed shall be delivered as directed by the Owner, or discarded as the painting systerls and materials and their use. Comply with all manufacturers P ED RECON CsURED TENANT , REAS. shall conform to established schedule for elimination of architectural Owner may direct. recommendations In the use of their respective products. Color 4 Sheen barriers per ADAAG guideiirer- Workr ansKp and materials shall also Schedule: (to be selected by .others) CLARIFICATIONS: a.) THE 24" x 48" LAY-IN SUSPENDED ACOUSTICAL CEILING EXISTS AND NO ALTERATION 15 conform to the latest adopted building code edition and to conditions and 20. Contractor to keep area of work free of waste and deb;-is as work ANTICIPATED WITHIN THE SCOPE OF THIS PROJECT, b.) THE H,V.A.C. MECHANICAL SYSTEM EXISTS: CHANGE`., ARE !; spec Fications of all gcverning authorities. progresses and maintain premises in neat and clean corrditlon. 29. Fire suppression sprinkler head locations shown at RSP ECTED CEILINCs E'�AN LIMITED TO RELOCATION OF DUCTS AND SUPPLY AND RETUF 1 DIFFUSERS AND GRILLS AS REQUIRED BY Ni:W OFFICE are existing, Alterations, if any, to existing automatic sprinkler system, smokeSUITE CONFIGURATION, AND c.) THERE 15 (1) EX15TING SINK AND RELATED PLUMBING WITHIN THE EXISTING SUITE WHICH 4. Application of materials by any Subcontractor to surfaces existing or 21. Contractor to provide and install metal frames and interior glazed detection, and fire aiarm and protection systems are to comply with all IS TO BE RELOCATED AS SHOWN ON PROPOSED FLOOR PLAN. ADDITIONAL PLUMBING ONLY AS REQUIRED FOR NOTED provided unc'er this contract shall imply acceptance and suitability of and relite frames to match pre-established tenant standard, or As Indicated current and prevailing state and local codes and regulations. Relative RELOCATION, to existing Lor,ditions. Such Subcontractor shall be held responsible for herei, cocrd'nats all measurements prior to fabrication and install all documents are to be developed and submitted by the Contractor for approval damage or irregularities to his product as a result of --svious conditions. frames plumb, in true alignment, and rigidly and securely anchored in place and implementation. j&i per manufacturer's recommendations and per requirements of relevant O 5. The Contractor shall obtain and a For all permits and fees, and all regulatory agencies. 30. Alterations to existing heating, ventilation, and air conditioning pay p 9 y 9 9 9- 9 additional drawings and specifications, if any, required for permits to be systems are to comply with all curr.snt codes and regulations. Contractor to supplied by General Contractor and Subcontractors. 22. All doors and hardware to comply with all prevailing codes and submit HVAC plan indicating supply and return ductwork, exhaust and regulations. All doors to be 3'- 0" wide X tenant standard height, flush ventilation ductwork and locations of grilles and registers for approval 6. The Contractor shall provide and pay For required dumpster(s), and wood, compliant with applicable provisions of AWI Quality 5tandarde 1300, prior to construction. ROBERT BECKER ` telephone as may be requested For his/her and his/her Subcontractors' use. with NWMA Standard DOOR Guarantees. All doors (and door Frames,) to be 3, tenant standard finish or to match existing therein, and be installed 31. Basic materials and methods For all new electrical services are to INTERIOR DESIGN & SPACE PLANNING <' 1, No storage outside the building shall be allowed without written plumb, In true alignment and securely anchored in place. Hardware ''finish: comp) with current relevant codes and regulations, and be compatible with 'l authorization of Building Owner, to match pre-established tenant standard. Operation: all doors shall havetenants existing services including receptacles. All electrical designs 9660 S.l►. Eagle Ct. non-lockable latcheets with A_DA. compliant lever handles, unlese as noted for required system revisions and additions to be by Electrical Contractor Beaverton, 7 8. Owner and Tenant shall not be responsible for tools or material goods otherwise. Doors shall be operable from the inside without the use of a key who is to submit plans and specifications to Owner and Tenant8 s For review tet' (503) 646-1862toi4 Oregon 9fax: (70000 626-8039 stolen or damaged on site, or any special knowledge or effort. and approval prior to construction, pay all fees and obtain all permits and approvals from governing agencies necessary to complete work, and --- -- - - - - - - -- --- 9. Upon completion of work the Contractor shall thoroughly clean the 23. RoIi�s (glazing) General; No new relites are included within the scope coordinate with the General Contractor those items for demolition not DESIGN BY: DRAWN BY: premises so that the tenant area is acceptable for occupancy by Tenant. of this project.. specifically indicated herein, PROJECT: 10. All substitution requests shall be submitted to, and approved by Owner, 24. , mr il: General: Provide gypsum drywall compliant with 32, Contractor to disconnect and cap designated utilities within demolition PROPOSED REMODEL OF EXISTING Tenant, and Designer, prior to implementation. applicable guidelines established by Northwest Lath and Plaster Bureau. areas anti accurately record actual locations of capped utilities, if any. S.W. LEHMAN ST. TENANT IMPROVEMENTS FOR: All exposed gyp. bd. to be taped and sanded to match pre-established RAND WORLDWIDE 11. Provide submittals as specified herein r-rlor to application or ordering surface tsxture per "tenant standard". Construction: All non-load bearing 33. General Contractor to coordinate all systems to be located in and above product and material. gypsum drywall tenant standard partitions to extend to underside or the catling, including fire protection, smoke detectors, H.v.A.C,, - -- -- existing suspended celling system per tenant standard partition detail, electrical systems and security systems. F?ecel Contractor to confirm SITE r,oc.4Tlv,v: EXISTING SMITE 100 12. (not used) Partitions to be 5/8" gypsum board on both stoles 2-1/2" metal studs at 16" receptacle types with Tenant and match existing outlets and coverplates For COLUMBIA BUSINESS CENTER o.c., unless otherwise directed by Owner. Contractor to provide additional consistency of color, unlass otherwise instructed by Tenant. Outlet, S.W. CORAL Si. 13. Contractor to perfC'.i demolition and alterations to existing tenant sway bracing at all partitions as may be required by current seismic switches and cover plate colors are to be selected by Tenant. Switch colors 9900 S.W. GREENBURG RD. improvements in accordance with these Contract Documents, conform to all requircmente, and as may be approved by City of Tigard, and outlet colors may be different as may be designated by Tenant. ? PORTLAND, OR. 97223 applicable codes For demolition work and removal, and obtain required Contractor to provide electrical, telephone, and data/communication permits from appropriate governing agencies. Contractor to coordinate the 25. Acoustical Ceiling suspension system exists and Is to be retained with receptacles or outlets as Indicated on plen At +IS" d,f.f., unless SHEEN 77TLE: SCALE: removal and disposal of all existing building materials scheduled to be no modification unless Contractor to determine non-compliance, if any, to otherwise noted, SITE PLAN removed with Owner. Contractor to patch, repair or replace any surface and appropriate seism:c zone bracing requirements, and where required by material not designated For demolition but is damaged during construction. prevailing codes and regulations, provide additional ceiling suspension 34, Contractor to provide tenant standarc recessed 2' X s' and commensurate S.W. LOCLIST ST. LOCATION PLAN Owner and Contractor will determine the extent of repair required to return members, acceascrles and bracing to structure. Contractor to replace 2' X 2' fluorescent lighting per FEFLECTED CEILING PLAIy. Any conflicts to TYPICAL PARTITION DETAILS AS SHOWN affected areas! to original condition or better, damaged or stained celling tiles with new, and replace or repaint damaged placement of fixtures as shown herein are to be brought to the attention of celling grid as may be required. Acoustical Ceiling tiles to conform to Designer and Tenant. Contractor to verify circuits and switching with ne5lgner GENERAL NOTES 14. Contractor to submit For Owner and Tenant approval a schedule showing all prevailing codes and regulations. Install all materials In accordance and Tenant prior to installation, commencement, order and completion dates for various parts of this work with manufacturer's recommendations. Finished celling to be uniform In before commencing alteration or demolition- appearance. 35. Contractor to provide and Install box, pullstring and conduit, as may SHEET: T: be required for tel/data communication where Indicated. Tel/data cable, 15. Contractor to notify Owner prior to performing work which will generate 26. Contractor and Carpet Subcontractor shall provide and Install connectors and coverplates/receptacles by tenant's vendor(s). smoke or dust as exleting Fire alarm system may be sensitive to these carpetin , and underlayment, IF any, in accordance with tenant standards particles. and per enant selections. Contractor to submit carpet seaming diagrams for 36. Emergency exit lighting, fire alarms, and sprinkler system locations ALL DIMENSIONS SHOWN OR IMPLIED ARE AND SUBJECT TO REVISIONS PER VERIFICATION ' AP .4TE � all areas noted to receive new carpet Installation to Owner and Tenant for and alterations to existing are to be provided in accordance with governing 1OOfF' 16. Contractor tc notify affected utility companies before starting work approval prior to procesdirg. state and local codes. F,XISTING SITE CONDITIONS. and comply with their requirements, and Is riot to disable or disrupt Hwy �.. 11 building fire cr life safety systems without prior written notice to Owner. 21. (not used) 31. Provide any modifications to life safety systems as may be required to conform to all governing codes and regulations. NO. ISSUANCE DATF,': 11, Contractor to provide, erect and m6intain lights, barriers, warning - ___t -- -- - --- signs, and other items as may be required far proper protection of the 38. Contractor shall field verify all dimensions and conditions prior to I56UE-D FOR APPROVALS, FINAL PRICING public, occupants of building, workmen and adjacent construction and take starting demolition and construction and report any discrepancies to the AND PERMITS MARCH 1, 2001 necessary precautions to prevent dust and dirt from rising, construct and Designer. Where confllcte may occur between new construction, fixtures and maintain temporary partitions as may be required to prevent the spread of equipment in6lcaLe01 to be installed in, or acdjL.)ining the existing celling, Greenbura Rd. #100, 9900 dust, odors and noise, protect unaltered portions of existing bullding by structure, plumbing, fire protection, electrical, and W/,4(-- systems,systems, the duf'zool-000so dustproof psrtitions and other adequa+p means, not close or obstruct Contractor Is to bring to the attention of Designer, tenant or Owner before 1 SITE PLAN 1 °t 2 NORTH walkway widths to exits as may comply with prevaliing codes and proceeding. A-1 N T regulations not store or place materials in passageways, stairs, or other means or egress, and conduct operations with minimum traffic interference I to general and public areas of the building and be responsible For damage f to e✓isting structure or contents NOTICE IF THE PRINT OR TYPE ON ANY 1 I I I III I I I I I I I I l i III I l II i l I l i III I I I II I I I l i I I I I I I c I I I I III III I I I I I I III III I I I I I i I III I l i I I I I I I I III III I I I I I I ; III III I I I I I I III 111 I I I I I l I I I I I I I I I I III III V I I I�jI IMAGE IS NOT AS CLEAR AS THIS NOTICE, No 38 3.1 I 141- --- I- II I L IL I- --I-- I-fit -- I --I-g� --I Ll .I _I _ .11 l- --I-- il� IT !S DUE TO THE QUALITY OF THE L IIIsIIi�IIIII�IIII I IIIIIIIIIIIIIIIIIIiII�IIfl�u99z j[ Ills; 1[ItivTIIiII1III 1I1IaII1III1IIIIIu � IliiIII[ ���ORIGINAL DOCUMENT Fln, III II sII�Iitil II<I11zII�110111zIlilllllll�lilI �uI u�ll(£ I llu�lL�llu��i I[II�II�I�,wII�S STRUCTURE �OB� Ci - LEGEND 01 1 '�� EXISTING PARTITION OR STRUCTURE TO REMAIN A) _ _ — - — _—— _ --- - 9 $ \ _l �_ I i r p - T i - - = > -- - R EXISTING PARTITION TO BE REMOVED - - -- ♦ ♦ + + F ♦ + $ + -- - F - - - - ---- I NEW TENANT StANJARD PARTITION 1 2 %�, + S + R ^----- NEW TENANT PARTITION WITH SOUND IN5ULATiON - _ -- N AMAX. x + - LATERAL BRACE + 12'-O"o.c. - - -- - --- _-- ___ __--- --..-.- 1 — _ --- . . _.__-- _-- i NEW TENANT DEMISINcx PARTITION W! SOUND INSULATION MAX. S 9 - - --- - --- - - - - - — _- L I T •- R RF E t } 4 TYP. SUSPENDED CEILING SECTION _ - DETAIL REFERENCE -- - - --- --- ---- - ^-- -- - - �_; -- SH L NUMBER -- - - -- TAI MB R N.T.S. + + + - - + - - °.uEETNUMBER a A•2 -- \ -- - -- - f S - ---- -- — - - -- - -- .. DOOR REFERENCE _-- -DOOR "ARDLU"RE NOTES - -- - s - - R Q• DOOR TYPE C� MAIN RUNNERS OF AN "INTERMEDIATE DUTY" SUSPENSION 9Y STEM AT 4'-0"o.c. ` ' - + + � + + - ri , �® 104 ROOM NUMBER SUPPORTED WITH No. 12 WIRES AT 4'-O"o.c. (OR No. 10 WIRES AT 5'-0"e_­.cJ - HANGER ATTACHMENT SH>LL SUPPORT 5 x CEILING LOAD 30 LBS. r11NIMUM. __ (I� PLAN REFERENCE NOTE O CROSS RUNNERS SUPPORTED BY MAIN RUNNERS OR OTHER CROS& RUNNERS +®+F `� DUPLEX ELECTRICAL OUTLET O PRO/IDE STABILIZER BAR BETWI=EN ALL MEMBERS AT PERIMI7ER. + 40 HANGER SYSTEM To BEGIN WITH B INCHES OF PERIMETER. $ FOUR-FLEX ELECTRICAL OUTLET ® LATERAL BRACING SYSTEM TO BEGIN WITHIN 6 FEET OF PERIMETER AND WITHIN EXISTING WALL MOUNTED OUTLET rO BE REMOVED 2 INCHES OF CROSS RUNNER INTERSECTION. (4) -- 12 GA. WIRE SECURED TO MAIN ) SPECIAL OUTLET A5 NOTED RUNNER AND SPAYED 50 DEGREES FROM EACH OTHER IN PLAN AND AT AN -- �- ANGLE NOT EXCEEDING 45 DEGREES FROM CEILING PLANE. BRACE AT EACH WAY. ♦ 'VOICE (TELEPHONE ' RECEPTACLE VERTICAL COMPRE°SION STRUT AT EACH LATERAL BRACE LOCATION. STRUT Q DATA (FAX/1"IODEr-1 ' RECEPTACLE TC BE 3/4'' SQ HD TUBING WITH SPRING CLIPS AT EACH END AS MANUFACTURED BY ROBLIN PRODUCT SYSTEMS, OR SIMILAR CONNECTION DEVICES To BE OF 7 COMBINED SERVICES RECEPTACLE APPROVED TYPE AND HAVE 100% COMPATIBILITY. 3 REFLECTED CEILING PLAN €3r-� FLUSH MOUNT FLOOR MONUMENT WITH SERVICES INDICATED AT HANGERS �10R,E THAN I:6 OUT OF PLUMB. PRO'/IDE COUNTER SLOPE HANGERS. -�� �-2 SCALE: 1/8" = 1'-0" D DEDICATED OUTLET WHERE HANGER WIRES ARE NOT P0551BLE DUE TO CONSTRUCTIONS, PROVIDE A TRAPEZE OR EQUIVALENT DEVICE. TRAPEZE SUSPENSIONS FOR SPANS EXCEEDING B BLANK COVER PLATE 40" SHALL BE A MINIMUM OF BACK-TO-BACK 1 I'4" GOLD ROLLED CHANNELS. EACH ANCHOR TO STURCTURE TO HAVE 100 LB.I"i NIMUM WITHDRAWAL STRENGTH. E EXISTING SERVICE OR FIXTURE TO REMAIN 10 LIC,1T FIXTURE SUPPORT: N NEW FIXTURE OR SERVICE A. WITH "INTERMEDIATE DUTY" SUSPENSION SYSTEMS, 12 G" ',GANGERS SHALL QJ JUNCTION BOX BE ATTACHED TO THE GRID MEMBERS WITHIN 3 INCHES OF EACH CORNER OF EACH FIXTURE. TANDEM FIXTURES, IF ANY,MAY USE COMMON WIRES. -- -- - - ---- _._ -_ -- _-- _ _-- _-- _ - -_ - - __ - -_-_ Q T E B. LIGHT FIXTURES WEIGHING LESS THAN 36 POUNDS REQUIRE TWO 12 GA. F_ SLACK WIRES FROM THE =IXTURE HOUSING TO THE STRUCTURE ABOVE. MULLION Cj MULLION E E E E C. LIGHT FIXTURES IN EXCESS OF 36 POUNDS SHALL BE SUPPORTED i E DIRECTLY FROM THE STRUCTURE ABOVE. ___ __ __ _..___ _ __ _ ... _,-._...- ---- OPEN _- -� -- - --- - - ---_ - = GE EXISTING 2' x 4' FLUORESCENT FIXTURE TO REMAIN D. ALL Li3HTING FIXTURES SHALL BE POSITIVELY ATTACHED TO THE CEILING FTE N I I E E E E 011E - EYY E E E I E 02 SYSPENSION SYSTEM WITH TEE BAR LIGHT CLIPS OR SIMILAR DEVICES. +ISE' 0SINK I I 103 t� 1r02 BLDG. F— E ' _ EXISTING 2' x 4' FLUORESCENT FIXTURE TO BE REMOVED II ANY INTERIOR PARTITION WALL WHICH EXTENDS TO THE CEILING GRID THAT DOES +4.21 E I A 2 CFE ICE OFFICE QFFICE a � R q ROOM NOT ALIGN WITH THE 4-W4Y BRACING OF THE CEILING GRID MUST HAVE ITS OWN B I NI I O2 -- - 106 105 104 E[ 9 NEW OR RELOCATED 2' x 4' FLUORESCENT FIXTURE LATERAL BRACING, PER NOTE 5 ABOVE AT 12'o c.,MINIMUM. E I F 4 LUNCH I E 12J> SUSPENSION SYSTEM TO COMPLY WITH U.B.C. TABLE 25-A. E I J I 10 I E Q Q Q E _ -_ El EXISTING 2' x 2' FLUORESCENT FIXTURE TO REMAIN -- -[Q R R GOATS C 1 EXISTING S" x 4' FLUORE5CENT FIXTURE TO REMAIN TRAINING \ - 9 o E (6, NAL 101 DOOR SCHEDULE NN 108L== OPEN AREA 11`� F O RECESSED INCANDESCENT DOWNLIGHT E HALL 112 - - -- -- - G RECESSED WALL WASH LIGHT F-IXTURE --- I I1 E Q "E E - z E E E �a I I I I N �_ - ,O; EXISTING DOWNL!G;J TO BE REMOVED Y m/ E REGEPT. TEMPERED N 100 R - i i' GLASS A$ B E OFFICE N e' ® EXIT SIGN RECIV. B E 113 0 j��`O (E • EXISTING) N E E R N NIGHT OR EMERGENCY LIGHTING E E E E E E E LIGHT SWITCH E (D = DIMMER) HALL TEL.-'RM, - I©9 110 5 EXISTING H.VA.C. SUPPLY TYPE ,4 TYPE B - TYPE C TYPED � o I � EXISTING H.VA.C. RETURN TYPICAL TENANT: TYPICAL TENANT TYP'CAL TENANT EXISTING TO REMAIN, IJ I � - i � + EXISTING 5FRINKLER HEAD SOLID CORE, INTERIOR DOOR: INTERIOR DOOR W1 PAINTED PAINTED OR WOOD HOLLOW CORE, FULL HT. VISION PANEL: TOM�.TCH EXISTING TTOAINTED MATCH EX15TTIING TTOPAINTED MATCHOEXI��NG 2 PROPOSED FLOOR PLAN NOT o. �-2 SCALE: 1/8" = 1'-0" • DOOR FRAMES TO MATCH EX15TING TENANT STANDARD, TYPICAL, UNLESS OTHERWISE NOTED. PLAN • DOORS 4 HARDWARE TO CONFORM TO ALL CURRENT ADA CODES 4 REGULATIONS. PLAN NOTES 0 REMOVE EXISTING UPPER AND LOWER CASEWORK (POTENTIALLY TO BE RELOCATED HARDWARE SCHEDULE: TO NEW LOCATION), DEMOLISH EXISTING STORAGE CLOSET WITH DOOR, DEMOLI5H PORTION OF WALL AND DOOR OPENING INTO TRAINING: 108 AND REUSE DOOR IN NEW ROBERT BECKER TYF� 1 1/2 PAIR BUTTS TYPE C: CLOSURE LOCATION SHOWN, AND RELOCATE EXISTING PLUMBING TO NEW LOCATION IN LUNCH: 10-1. LATCHSET W/ LEVER HANDLE 1 1/2 PAIR BUTTS ADAPT AND RELOCATE EXISTING CASEWORK OR PROVIDE AND INSTALL NEW UPPER INTERIOR DESIGN & SPACE PLANNING WALL 5TGP LATCH5ET W1 LEVER HANDLE AND LOWER CASEWORK (AS MAY BE DETERMINED BY ECONOMICS (VERIFY)) WITH SINK. WALL STOP 9660 S.W. Eagle Ct. 3 REMOVE EXISTING RELITE, INFILL OPENING AND PATCH AND REPAIR WALL TO MATCH Beaverton, Oregon 9703) 08 Tl_P� f3: 11i2 PAIR BUTTS TYPE D: _ EXISTING TO REMAIN tel: (503) 646-1862 fax: (503) 626-8039 LOCK5ET W/ LEVER HANDLE (NO , HANGES) ADJACENT EXISTING WALL SURFACES TO REMAIN _ WALL STOP DES'fCN BY: DRAWN BY: r5DOOR & HARDWARE SCHEDULE PROPOSED REMODEL OF EXISTING Y A-2 N.T.S. TENANT IMPROVEMENTS FOR: ---- --- -- - -- ---- -- --- - - - - - - -- _ , . RAND_ WORLDWIDE F _ - -- --- -� � E - LOCATION: EXISTING SUITE 100 --- (4) EQUAL DOORS TO MATCH LOWER r COLUMBIA BUSINESS CENTER CASEWORK ---- ------ 3--- - — — - —�� _ - - w r 9900 S.W. GREENBURG RD. A P E ---- E SINK E E E E E E E E E T�= rd PORTLAND, OR. 97223 I8 E E E_ +1,2 E E ° SHEET TI RLE: SLA 1 / II IIlQr BE EIS a E - - EXISTING FLOOR PLAN E ADJ. SHELVES ; : ; (2) ADJUSTABLE E REF -- - — - - PROPOSED FLOOR PLAN SHELVES ` E R R AS SHOWN -GLASS REFLECTED CEILING PLAN E ' E�= DETAILS a ` _1 E SHEET. E C4 I 1 x 4 FLAS. LAM. `; -_ r-PLAS. LAM. (t) - E �E E 7 E 9 V T EN���f-1 I BAGKSPLASN ' -� ALL DIMENSIONS SHOWN OR IMPLIED ARE APPROXIMATE � SINK B !_ - AND SUBJECT TO REVISIONS PER VNRIFICA77ON OF - ( EXISTING SITE CONDITIONS. E R 2 iU ADJ. SHELF E E E E E E: E E E "4" RUBBER 5A5E 6 _ L_. _ --_JL._____ -- ___J _ ff ._ L. E I NO. ISSUANCE DATE;: 3/4" F _-� I ISSUED FOR APPROVAL$, FINAL PRICING E ADJ SHELF SECTION •A=•A• 44" I AND PERMITS MARCH 1, 2001 EG�u<,� DOORS - 36" CLR _ _ - -_-_--- ---- ---- FOR REFRIG ADA.ACCESSIBLE (VERIFY) a" TOE KICK IS TO • ALL vI5IBLE SURFACES TO BE PLASTIC LAMINATE. BE INTEGRAL WITH DOOR FLOOR FIN. DOOR PULLS PER PRE-ESTABLISED TENANT STANDARD TO CONTINUE :9'-6" (VERIFY) _-- • HEAVY DUTY CONCEALED HINGES, T'I'P. - - - Greenburq Rd.#100, 9900 � 6 LUNCH: 107 rl EXISTING FLOOR PLAN z��`'?°°'00090 NORTH q �-2 SCALE: 3/8" = 1'- A-2SCALE: 1/8', = 1'-W, NC'TICE: IF THE PRINT OR TYPE ON ANY 1 I 1111 1 I 1 11 I I I l i l I l l 1 1 I I III III III III ' 11 I ' I I I III (I I III III III I I 1 1 1 1 1 1 1 III III III III III III ' III III III III III III III I I III III ! 111111 III III I I I I 1 T___.� I � 1 61 - -- '7 - -- .glo ---- - 11 IMAGE IS NOT AS CLEAR AS THIS NOTICE, L---- --1 .`�-1 _---- -'' -------- -1 �l 1 � _L 1 -L _— —IT IS DUE TO THE QUALITY OF THE "°'g ORIGINAL DOCUMENT 8Z 8 7. L Z 9 Z Z 6 Z E Z Z TZ O Z 6 i B T L T 911 T �Z T iff T II T 6 ff 8 1L I9 9- I1I �£ II ��ZI ��T a r • f ! IIII I �I II Ill�lllllllll�lllllllll�lllllllllllllllllil�llllllllllilllllllllllllllll�Ill'�IIII�IIIIIIIIilLW�11111111�LLl�II� IIIIII�III�IIlI11lIl�IIIIIINII II I�IIIII�I Illllllll�lll�ll►I�II1111111�111►IIIIII►11111 1111111-11►II►III 11-111111 I�► II�III I, I 11.,111 III► IIIIII IIIII�