12855 SW GRANT AVENUE-4 80 76 60 50 40 30 20 10 0 LO N fn STANDARD MECHANICAL ABBREVIATIONS _ _ MISC . VALVES & COCKS PLUMBING SYMBOLS_ PLUMBING EQUIPMENT _SCHEDULE _ q � a I AF AIRFOIL ID INSIDE(DIAMETER/DIMENSION) - - - SHUT-OFF VALVE -11 CO CLEANOUT ITEM DESCRIPTION ELECTRICAL C) o i AFF ABOVE FINISHED FLOOR IE INVERT ELEVATION -- -- GLOBE VALVE -i WCU WALL CLEANOUT IJ AHP APPARATUS HOUSING PLENUM IN INCH(ES) s DET-1 DMS-IiC WATER EXPANSION TANK ,- w --- �Q -- SHUT-OFF VALVE W/ TAMPER SWITCH —.—. .— —0 FCO FLOOR CLFANOUT DET-2 10.0 'ALLONS ACCEPTANCE VOLUME ALT ALTERNATIVE INSUL INSULATION - AL ALUMINUM ISOL ISOLAT(OR)(ION) -- -� CHECK VALVE --.- -Q CTG CLEANOUT TO GRADE 12.5 GALLONS TANK VOLUME APD AIR PRESSURE DROP KW KILOWATT BALANCING VALVE -- -" - ---(j FD FLOOR DRAIN BASED ON: AMTROL AST-30 Z J APPROX APPROXIMATELY KWH KILOWATT HOUR --------- rC - ARCH ARCHITECT(URAL) L LENGTH � FLOW CONTROL VALVE ----- - --� FS FLOOR SINK GPRV-1 GAS PRESSURE REDUCING VALVE - < ' AUTO AUTOMATIC LAT LEAVING AIR TEMP -__---- _ Is] - ---- --� RD ROOF DRAIN (GWH-1) 240 CFH INPUT, 2 PSIG INLET PRESSURE. I BDD BACKDRAFT DAMPER LB POUND SOLENOID VALVE __ --� ;�U OVERFLOW DRAIN GP V- OUTLET PRESSURE TO BE COMPATIBLE WITH EQUIPMENT `_ N p (GWH-2) BASED ON: MAXITROL 325-3LX ('/s ) 3� L I BI BACKWARD INCLINED LOB LEAVING DRY BULB ---fie PRESSURE REDUCING VALVELO BLDG BUILDING LF LINEAR FEET ____T My _ -- - AIR VENT (MANUAL/AUTOMATIC) -- 2ff___3 GAS PRESSURE REDUCING YALVE - v3 1 BSMT BASEMENT LFT LOVING FLUID TEMPERATURE - - --� RELIEF VALVE PLUMBING PIPING (KITCHEN) 180 CFH INPUT, 2 PSIG INLET PRESSURE. � BTU BRITISH THERMAL UNIT LVG LEAVING OUTLET PRESSURE, STC (1/2 PSIG) PRESSURE BTUH BRITISH 1HERMAL UNITS PER HOUR LWB LEAVING WET BULB .+ STRAINER BASED ON: MAXITROL 325-5ALX3/4"L W WASTE (ABOVE GRADE OR FLOOR) -- _. (3/4") CFH CUBIC FEE- PER HOUR LWT LEAVING WATER TEMPERATURE - - STRAINER W/ BLOWDOWN W WASTE CFM CUBIC FEE- PER MINUTE MAX MAXIMUM - -- - -� - (BELOW GRADE OR FLOOR) GPRV-81 SAS PRESSURE REDUCING VALV CFS CUBIC FEET PER SECOND MBH THOUSAND BTU PER HOUR - -- IN DRAIN VALVE PW v PW PUMPED WASTE (ABOVE GRADE OR FLOOR) (B-1) 1200 CFH INPUT, 2 PSIG INL FT PRESSURE. CLG CEILING OR COOLING MECH MECHANICAL - - i H6 HOSE BIBB SD SD STORM DRAIN (ABOVE GRADE OR r�JOR) GPRV-82 OUTLET PRESSURE 70 9E COMPATIBLE WITH EQUIPMENT Yi (B-2) BASED ON: ROCKWELL 043 1 CONC CONCRETE MFR MANUFACTURER --- WH WALL HYDRANT OD OD OVERFLOW DRAIN (ABOVE GRADE OR FLOOR) - --- - - --- - -- -- ---- --- - - CONN CONNECT(ION) MIN MINIMUM i �-1 GAS WATER HEATER � D D DRAIN (CONDENSATE/INDIRECT) GWH-- 240 CFH INPUT 12 AMPS CONT CONTINUE(ED)(UATION) MISC MISCELLANEOUS PRESSURE GAUGE ----------- V VENT 100 GALLON STORAGE 4" VENT, 4" INTAKE 112 1 S j CL CENTERLINE MTD MOUNTED - --- - - DDC DIRECT DIGITAL CONTROL NC NORMALLY CLOSED - -_ - CW COLD WATER 273 GPH RECOVERY 0 100 F RISE I DEFL DEFLECTION NIC NOT IN CONTRACT PRESSURE/TEMPERATURE TEST PLUG HW HOT WATER BASED ON: A.O. SMITH BTH-250 I ON DOWN NO NORMALLY OPEN RHW RECIRCULATING HOT WATER RHWP-1 RECIRCULATING HOT WATER PUMP 1/s HP - j DP DEW POINT OAD OUTSIDE AIR DAMPER - -- THERMOMETER - -� ' I DWDI DOUBLE WIDTH DOUBLE INLET OC ON CENTER DISTANCE -- ---- FLOW SWITCH ""— HTW -""" H1W 140' HOT WATER IN-UNE CENTRIFUGAL PUMP 120V iPH DWG DRAWING OSA OUTSIDE AIR T G G NATURAL GAS (LOW PRESSURE) 10 GPM ® 27 FT HEAD pR� TEMPERATURE TRANSMITTER BASED ON: GRUNDFOS UP-26 998E \J IN EA EXHAUST AIR PH PHASE -- n - -- MPG MPG NATURAL GAS (2 PSI) - - - -- -_ - - 2 EAD EXHAUST AIR DAMPER PP POLYPROPYLENE `� IS11E1 SHOCK ARRESTOR NPW NPW NON-POTABLE WATER RPBP-1 REDUCED PRESSURE BACKFLOW PREVENTER _ 2 473 ~ --- ----- ------- EAT ENTERING AIR TEMPERATURE PSI POUNDS PER SQUARE INCH v 20 GPM 0 10 PSIG LOSS ---- GV ----- GV GAS VENT EDB ENTERING DRY BULB PVC POLYVINYL CHLORIDE ------ -- -- VACUUM BREAKER BASED ON: WATTS 1"-909QT-S EFF EFFICIENCY PVS PVC COATED STEEL WFM - -- WATER FLOW METER 23,` � SP-1 SUMP PUMP EFT ENTERING FLUID TEMPERATURE R (RAO) RADIUS RPeP V2 HP �A1- Szo ELEC ELECTRIC AL RA RETURN AIR - REDUCED PRESSURE BACKFLOW PREVENTER 10 GPM 0 35 FT HEAD it FIRE ELECTRIC(AL) DDG SYMBOLS ,2ov, 1PH ELCV ELEVATION RAD RETURN AIR DAMPER ---- DETECTOR DOUBLE CHECK ASSEMBLY BASED ON: PACO PIP-702A _ _ T ff: 12-31-03 BW E --- - - BACKWATER VALVE QA ACCESS PANEL NGR ENGINEER REV REVISION GEQ EQUAL RH _ EQUIP EQUIPMENT RPM REbOLIUTIONS IPER MINUTE - rJ VE DITYUNDERGROUND GATE VALVE W/BOX BELOW GRADE / FLOOR I- LU M B N G FIXTURE SCHEDULE ESP EXTERNA STATIC PRESSURE SA SUPPLY AIR -��---- - UNDERGROUND GATE W/POST INDICATOR ROUGH-LN SIZE - INCHES a s o N EWB ENTERING WET BULB SCFM STANDARD CUBIC FEET PER MINUTE - OUTSIDE SCREW & YOKE © POINT OF CONNECTION ITEM DESCRIPTIONW V HW NOTES °ywaa ___.�__ i O N N EWT ENTERING WATER TEMPERATURE SD SMOKE DAMPER �;N �n EX EXTRACTOR SECT SECTION EXH 1 NOTE WC-1 WATER CLOSET 4" _2" 1 r/z" - FLOOR MOUNTED_ _ 5 EXIST EXIST NG Sim UST c SIMILAR SENSIBLE _ MISC . FITTINGS & S Y M B 0 L S UC 12 WATER URINAL CLOSET � 1/2" 11/44" = WALL HMOUNTED, ADA NG EXP EXPANSION SP STATIC PRESSURE _ " � -� -- -- - F DEGREES FAHRENHEIT SPEC SPECIFICATION _ - - DIRECTION OF FLOW U-2 URINAL _ 2 1 /2 1 /4 =_ WALL WING, ADA 3 FC FORWARD CURVED SQ SQUARE -- ---- - DIRECTION OF SLOPE - -- ----- 3 - FIG FIGURE SF SQUARE FOOT FEET -____.__—�______ L-1 LAVATORY 2" It/z" t/z" t/z" WALL HUNG, 20"x19", ADA ' PIPE SLEEVE S-1 SINK _ 2" 11/z" 3/4" 3/4" COUNTERTOP, 22"x19"x61/z ADA___ FI LT FILTER SQ IN SQUARE INCH(ES) ) - S-2 SINK 2" 11/2" 3/4" 3/4"- COUNTERTOP, CLASSROOM W/BU136L-CR FLEX FLEXIBLE SS STAINLESS STEEL ---- --�-- REDUCER 31"x19"61/2", ADA 5 FPD FLUID PRESSURE DROP STL STEEL - -- - ANCHOR FPM FEET PER MINUTE STRUCT STRUCTUR(E)(AL) � ELBOW 90' - ` S-3 SINK 2" 11/2" 3/4" 3/4" COUNTERTOP, DOUBT F BOWL, FPS FEET -FR SECOND SWP SINGLE WALL PLENUM ( ) 33"x19"x6'h", ADA -----___._. - ---�-- ----- __ _- -- FT FEET/1' ELBOW SWSI SINGLE WIDTH SINGLE INLET -' ( ) S-4 SINK 2" 11/2' 1/2" 1/2" COUNTERTOP, 22'x`19%61/2% , ADA FTR FINNED TUBE RADIATOR TEMP TEMPERATURE TEE MS-1 MOP SINK__- 3" 2" 3/4" 3/4" FLOOR/CORNER MOUNTED FU FIXTURE UNIT TSP TOTAL STATIC PRESSURE CROSS DF-1 DRINKING FOUNTAIN 2" 1'/z" t/z" - DUAL HEIGHT, ADA FLIT FUTURE TYP TYPICAL `- ----- _ __^--- FV FACE VELOCITY V VOLTS _-._.__. WH-1 WALL HYDRANT - - 3/4" - BOX/FLUSH TYPE W/LOCKING COVER GA GAGE/GAUGE VD VOLUME DAMPER -- -- PIPING CONNECTIONS JACUUM BREAKER, NON-FREEZE GAL GALLON VEL VELOCIT'f T- JOINT OR COUPLING POINT HB-1 HOSE BIBB - - 3/4" - LOCKING COVER, VACUUM BREAKER GALV GALVANIZED VERT VERTICAL - -- --_- -- - - - -- -- �- -� GLY GLYCOL VFD VARIABLE FREQUENCY DRIVE --oil UNION SB-1 CLOTHES WASHER 2" 11/2" 3/4" 3/4" RECESSED, TOP SUPPLY -- - - - - - ---- -- W GPH GALLONS PER HOUR VTR VENT THROUGH ROOF FLANGED CONNECTION SUPPLY BOX GPM GALLONS PER MINUTE W WIDTH WS`1 WATER SUPPLY - - 1/2" - 4 H HEIGHT 1VG WATER GAUGE _ —� CAF GENERAL NOTES: 4 UU HORIZ HORIZONTAL 'VPD WATER PRESSURE DROP - --II PLUG OR BLIND FLANGE HP HORSEPOWER W/ WITH c RISER 1. PIPE SIZE ON CONNECTION SCHEDULES ARE FOR INDIVIDUAL FIXTURE REQUIREMENTS. Q N I HTG HEATING W/O WITHOUT -- -o ELBOW UP N -- ELBOW DOWN 2. PLUMBING DRAWINGS ARE GENERALLY DIAGRAMMATIC. VERIFY FIXTURE L&X'ONS AND MOUNTING Cn PLUMBING DESIGN C R I T E R I A FOregon ) -�- HEIGHTS WITH ARCHITECTURAL DRAWINGS. VERIFY ROUGH-IN REQUIREMENTS rRIOR TO INSTALLING w �--- -v- TEE UP ANY FIXTURE OR EQUIPMENT FURNISHED BY OWNER. DOMESTIC WATER PIPING SYSTEM - ----_-_ TEE DOWN --- - --1-- HORIZONTAL TEE 3. PRIME ALL FLOOR DRAINS AND FLOOR SINKS. �.,� -, p BASIS OF DESIGN: 2000 OREGON STATE PLUMBING SPECIALTY CODE APPENDIX A "SIZING 'NATER _ L.0 I- --�- ----- FLEXIBLE CONNECTION C7 = cn ri SYSTEMS". PIPING SIZED ON 3 PSI/100 F-1. DROP, NOT TO EXCEED 8 FT./SEC. VELOCITY. - 4. INSTALL ALL WATER PIPING ON INSIDE. WARM SIDE, OF BUILDING INSULATION. T= BALL JOINT ® a < WASTE AND VENT PIPING SYSTEM - - --- --- MECHANICAL COUPLING 5. ALL PLUMBING PIPING SHALL BE SEISMICALLY RESTRAINED. S Z o BASIS OF DESIGN: 2000 OREGON STATE PLUMBING SPECIALTY CODE, CHAPTER 7 "SANITARY DRAINAGE"'. V o a s ALL WASTE PIPING SIZED AT 1/4",/FT. UNLESS OTHERWISE NOTED. - m y BASOIS OF (DESIGN: 2000I OREGON TATEErPLUMBING SPECIALTY CODE, CHAPTER 11 "STORM AND TIRE PROTECTION SYMBOLS KITCHEN EQUIPMENT SCHEDULE M z 1- 5 GROUNDWATER DRAINAGE." STORM DRAIN PIPING SIZED AT 1/4"/FT SLOPE UNLESS OTHERWISE F FIRE PROTECTION ROUGH-IN SIZE - INCHES 5 Q ti S z INDICATED ON DRAWINGS. __SPR FIRE SPRINKLER ITEM DESCRIPTION CW HW W V IW G NOTES L DP DRY PIPE SPRINKLER z NATURAL CAS SYSTEM 15 RANGE - - - - - 3/4 60 A!BH 0 5.0" W.C. W BASIS OF DESIGN: 2002 OREGON STATE: MECHANICAL SPECIALTY CODE, APPENDIX C, - - ------- - - --- - - ----- --- -- - ---- FLOW SWITCH - . . -- ---- --_._-- -- ------- - ---- --- � Q "FUEL GAS" SECTION C402 PiPE SIZING. EQUIVALENT LENGTH OF PIPE: 500 FT (MPG), 100 FT (G) S 16 CONVECTION OVEN (TWO) - - - - (2)3/4 (2) 60 MBH - TOTAL 120 MBH 0 7.0"-10.5" W.C. (D 1 SUPERVISED SHUT-OFF VALVE 3 W ~ (� 21 HAND SINK W/FAUCET 22 1/2 1/2 11/2 11/2 - - CONNECT 1/2 HW & CW TO MIXING VALVE & INLET CHECKS L J j FIRE PROTECTION DESIGN l"R I T E R I A PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR. PROVIDE i 1/4' PIPING & CONNECTION BETWEEN MIXING VALVE & FAUCET. FIRE PROTECTION SPRINKLER DESIGN CRITERIA -- --- - - -- -- --- - - - -- - - -- -- - - -- ~ ! CLASSIFIED AS ORDINARY HAZARD GROUP 2. SYSTEM TO BE HYDRAULICALLY CALCULATED. 23 CHEF'S SINK W/FAUCET 25 1/2 1/2 - - 11/2 - - LL SYSTEM TO BE' WET PIPE EXCEPT FOR AREAS SUBJECT TO FREEZING WHERE DRY PIPE IS TO BE USED. 26 CULINARY SINK W/FAUCETS 28 1/2 1/2 - - 11/2 - SINK HAS TWO FAUCETS EACH WITH 1/2" HW & CW INLETS, PROVIDE 11/2" CONTINUOUS WASTE. DRAIN TO OVER FLOOR SINK 6 27 WASTE DISPOSER 1/2 - 2 2 - - SEE DETAIL 6 issue date: 15 SEPT 2003 35 DISHWASHER W/BOOSTER - 3/4 - - 2 - SEE DETAIL job number. 0311 a revisions: 38 C-T;E RINSE SINK W/FAUCET �37 1/2 1/2 - - - - - (47 MOP SINK W/FAUCET 50 3/4 3/4 3 2 GENERAL NOTES: f` 1. PLUMBING DRAWINGS ARE NOT TO BE USED FOR ESTABLISHING ROUGH-IN LOCATIONS. REFER TO DIMENSIONAL- DRAWINGS PREPARED BY THE ttoARO „ KITCHEN EQUIPMENT CONTRACTOR. (KEC) � pDlvlglON 2. UNDER KITCHEN EQUIPMENT WORK OF DIVISION 11: A. FURNISH FAUCETS FOR EQUIPMCNT. _ CITY OF TIGARD 3. UNDER PLUMBING WORK OF DIVISION 15: 7 Approved,#_#_+�•gx..!PIM�; ,.,.,,..,, I XI A. MAKE ALL ROUGH-INS AND FINAL CONNECTIONS IN CONFGRMANCE WITH LOCAL CODES. PROVIDE SUPPLY SHUT-OFF VALVES WITH PERMANENT 7 LEGENDS AND ConditionallyApprovod..........................L I: NAME TAGS IDENTIFYING SUPPLY LINES TO EACH INDIVIDUAL PIECE OF EQUIPMENT. INCLUDE TRAPS, TAIL PIECES, AND LINE STRAINERS AS For only 1ne work as described in: REQUIRED. ABBREVIATIONS PERMIT NO. PLUMBING -�1M_2ntzL_�Qog_� B. FURNISH AND 'NSTALL ALL SINK WASTE LINES. PIPE SINK INDIRECTLY TO OVER FLOOR SINK. See Letter to: Follow...............................1 ]; C. INSTALL AND t;ONNECT FAUCETS PROVIDED BY KITCHEN EQUIPMENT CONTRACTOR. I bI 5$' Attach...............................( ): 0. FURNISH AND INSTALL CHROME PLATED VACUUM BREAKER ON SUPPLY LINES TO DISPOSAL. JobAddress:_ E. FURNISH AND INSTALL STAINLESS STEEL OR CHROME PLATED ESCUTCHEON PLATES FOR ALL WATER LINES PENETRATING COUNTER TOPS AND BACK Uy - _� i-�11�•�-sem.___bate: to l'21 STASHES. F. FURNISH AND INSTALL WATER PRESSURE REDUCING VALVES AS REQUIRED, MAXIMUM WATER PRESSURE AT BOOSTER HEATERS AND DISHWASHERS file name: J494P01 SHALL BE 20 PSI. G. PROVIDE 140 'F HOT WATER SUPPLY AT DISHWASHER AND BOOSTER HEATER. VERIFY REQUIRED TEMPERATURE FOR SUPPLY AT SINK FAUCETS WITH CODES. H. FURNI'JH AND INSTALL A SOLENOID VALVE ON PRIMARY GAS SUPPLY TO SHUT-OFF EQUIPMENT DURING FIRE SYSTEM ACTIVATION. �"� 4. SEE FOOD SERVICE DRAWINGS FOR ADDITIONAL REQUIREMENTS. Pool C 12855 SW(.11RAW AVE 1.14 H0 70 60 50 40 30 20 10 90 '� "0349400" 3494�'01.dwg x:ST20P,MEF o13494TU michelle [XES8825F XES8825 XES8825F.ctb] P1.�12u1►1-tt11508 A OFFICE COPY NOIICE IFTHE PRINT ORTYPE ONANY �- 11 JI + I1-- � 1I 1 , II i11 I12 Z0 5 IMAGE IS NOT AS CLEAR AS THIS NOTICE, ` IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMFNT ( �s �T. 1�. 1-1 till, II III Illi iliiIIItr, l�llli1111 lil lll1111111111111llllllllllllllllll1l lltilll�llll iill Illi II 11111111 ilil�!IIii1I1I�IlIifi111�Ilillilll�III �I11111111111I1i iIII�IIiIIIIfLIII I�I111 iill�illl i1l�Llll L 111111Lu�ilLlll9 �lllilllillilllluil lliilNll ; F' 80 80 70 ' 60 50 40 30 20 10 0 dO O ," N x rm oU � ct , i ,,-� �-� i (8 11� (11) (14(15) (111 (19) (20) (?.11 (23 �25�(26 X29 ;30� (,31) CC N I/A N M CD ll t I I c"i Z N 3 O �• d ' I C N L.__1-- —� GENEM NOTES• ' 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT ., I.E. _ -3.5' ` _� _ _ ____ ___ �_ __ _ I -� C SSD- FLOOR PENETRATIONS AND FIXTURE LOCATIONS. i (800 SQ FT)--,,,,,I F �, I.E. - -3.5 I I (800 SQ FT) Iq 7 t I FOR CONTINUATION CTO TSD UP a�b+`G TSD UP G FOR CONTINUATION g k i SEE CML DRAWINGS II tI rW UP J I II II rW UP SEE CML DRAWINGS I � . � CLASSROOM G�\,�G L•I1'�SSf�`� r rW UP - m ?C �I 2'W UP I F UP TO ✓ 2 4735 2 wco I + LJ O J.r. �. �.. .�.. ..�. .� �.� .�.. — I I F-IBES RESOURCE 3 2' I I ops iz-3,-a� CLASSR00 t /� CLASSRROM I IIS t III ' " I ��`��� IA, < I i JV b I *" rV UP I °°o••o S' I 4"�i W.UP 4" UP 7°NNtO O 2 Well 2N P N Q4"SD I ;�= � w° I I UP rV P �. �Q �J/X,� I YtI J 0. -3,5'I �; , . r�, i — 47W UP �, !ja C 4!SD (2910 SO FT) I I ^ :l: I I �. " 1 14" 3"W UP 4" �P I I I I.E - -�.5' I -4 SD UP ���_ � cu 4_ �-- I ��.,_ (2910 SQ FT) CTG �-- -T-� -_ __J - f ( I \»' I ^ " ItCTG FOR CONTINUATION G I STAR 3 �. I �I 41 2 W STA4�- 7­1 SEE CIVIL DRAWINGS G FOR CONTINUATION SEE CIVIL DRAWINGS :i t� I -'�0+ °'ac 2"W UP 3"SD UP s cc. I I s�°� HALL (EXPOSED) _ I ISD UP �._ (EXPOSED) I � I n. Q3"s0 I I.E. = -3.5' CTG �_ - r-- — -- — — L _� I- _ J — — — — ii r -r CTG C 3'SD- I ( 85 SC. FT) i I III I I-E. - -3.5 'I I ,I (185 SQ FT) I % z FOR CONTINUATION j II 4 SII - FOR CONTINUATION W SEE CIVIL DRAWINGS IL I I;I SEE CML DRAWINGS cc � SS r ` r a W s ROOM I CLASSROOM I' J �� - � N 1651 %7 „�' I r I (V CJS 2"w UP I �° `' 2"W UP o CL m CO WCDim/ z � o,r, w CD QI_4,__,RCCM I 4 t ° K CLASSROOM I Q z o t F { 21v UP I �- Q o m 1= " I L I _J i / �\ 4. L _J H=-- c=am u.; C VSD ( I I � I ' I.E. _ -3.5' 3250 SQ FT rVl UP ( ) - I I-- F-- I-- 'f 6 CTG I �' 3 " II'I - - I - - _4^yy IUP I � I 3"W UP till TG 5 < c� Q c -- — -- — — -_ 14 WJUP " UP I I I _ w _ F_ c� r— _ _FOR CONTINUATION _ _ �. -- -�-. -- =— y —_-- - f -- - = —' - -- - y FOR CONTINUATION SEE CIVIL DRA'tVINGS — 4"SD UP - I IR t 4� :A,o - 4"SD-UP = SEE CIVIL DRAWINGS W Q J I Ike Z" (!per_ J I I - _ . ?"W UP I- �; ' � " Q c� 2"W UP I �` I I I C 4 SD r» 3 -1 I — I W N 2"W UP I„ t I.E. - -3.5 _ .J 3 _D ( (3250 SQ FT) W r- II j 31W UP II + RESC;TO MS OFFICE U-iTO WCO I I UPJRCE ASSROCV. tis � � 3-W UP 2 V UP �4 OFFICE f�FAD '�li'-.F:'T � I i .C' --\ II 17 4 I ! I � I C3 IL it VI 2"W UP I '.G , :a 4 *% VIE Q - 2"W UP FOR CONTINUATION > .I j _.:r' _ 1� -- -- -- -- - --- ---i- 6 » UP ( = I _ .-__ _- -�- ----� I r r�v 6 issue date; 17 NOV 2003 SEE CIVIL DRAWINGS .-� 3 F�.=.1 ' , ' i ISR 'rR ION `� 14Qq o , _71Rq ' UP I'1 A108� - SE N U FOE CIVILTIDRAWINGS 7 �A job number. 0311 2"W UP 30 47W JP A SIO CTG 2"W U -_ J - - 2"W P — eu N revisions: — i I C1�G 1LoiT'1 1 ^ ,� .:...,�° I /t " " " i 4"SD UUP !,J Q4 SD_ i ( 4"$ i r1;�`c _ -.1.; 4 4 3 ' C 4"SD �1 FD DELETION 12�24�03 -3.5 D UP �.,... _.. _.. ....� 3250 SQ FT I :;b.••� ^ %' _... ,_..!_ ._ .._ ._ I t I I.E. = -3.5' 1 _ '. ( ) I 3 3" ;;j—J UNDERGROUND PLAN _ •� � _ ,� (3250 SQ FT) PN N (- 2"W UP 2"V UP 2" i I {' I - I - V: P SECTOR A PLUMBING �' I ,00'-0" .J _J h c:LASSRoorr aim -- j 2"W UP �" I I ,, .wcc 1 2"W UP I ( _ II --.u. MUM 6.0. .... ... � .rte I . .. � . .. ...". . .. ',+. ... . UNDERGROUND ,a eo PLANSECTOR ACLASSROOM I �.. l ( - 'SPECIAL E� I _ A PLUMBING I I Lim _ � ,. I f F I file name: - 3494P20A s �, c B ITT- 5EC1UR B - SEE I'2.08 s �` ' b SEC10R A _ SECTOR A �r ....r .w. s.,.. o..w +.■....� ..rrr - �r101� I rw�r�I15ECT - EE P�2 , PN N - - - = h _- :. _ - __ - - -- - - _ .�L- — - KE1/�'LA AVE 2-14 17 - - - --- ���� 855 5W GRANT NOT TO SCALE PLM2003-00508 DP26A 80 70 80 50 40 30 20 10 8 _ .. - -.. ,— -.,,,."", 11 r.. .,.� ... �.,.r - ,. .. .� 1; Maw NOTICE: IF THE PRINT OR TYPE ON ANY I l r r I l r�i 1 1 1 III I r i i it l r l i I I I i T (t rrl l r r1T r fr i t r1-TLi T I I TIT T l 11111 1111111111114 I l l Ill I l l r I 'l l l l l 111 I I f l l III ill I I I l l fl l I l 1 III 111 111 I Jill I IMAGE IS NOT AS CLEAR AS THIS NOTICE, I t 1 I I I � I 151 t I e� . t Il_I t t!) . I I d� _I I � I �(�/I 1- 3, IT IS DUE TO THE QUALITY OF THE _ �•� a - .. ORIGINAL DOCUMENT � II T — III IIIIIIIIIIII IIIIIIIII IIIIIIIII Illllllll Ill�lllllll IIIIIIIII illllllll Illullll IIIIIIIII IIIIIIIIIIIIIIII111 UIIlllll IIIIIIIII IIIIIIII�IIIIIIIIIlIIIIIIiI:IIIIIIIII IIIIIIIII T!l!!lll!!!llllllUlllll�lWll!l!lt111J 111►IIW lll IIrIIIIII gllllu!1811111111 tlJ�>r}11 ' 90 80 70 60 50 40 30 20 10 Ocn N co cn v Z O v w CV C= N O h- O ci p w in N cn 1 d FOR CONTINUATION N SEE CIVIL DRAWINGS---,j o C� 3"SO [= N I.E5. = -3. _ ' i � o (1386 SQ FT) j LO i ! CTG GENERAL NOTES: 1. REFER -FO ARCHITECTURAL DRAWINGS FOR EXACT i 0 L _� _ J - FLOOR PE JEIRATIONS AND FIXTURE LOCATIONS. tl) UP �*W r.N.",s �t_� J J ��r� _i I �ia �rr� �� w�ri� n SECT SEE P�� /^, ..r.�.e�i SECTOR A - SEE P2 DA ' I SECTOR 8 _ ._.. �: L1 - - - - SECT 'MUSIC I' ! I ,. t . _ M1. y ` ;� -- - - '' �l �� OR Q --� _ -- I � I - - - - �L r—+� I' - l I ;� -. - _ CF f : r ER I I �©6"F (FROM FDC 1 - - 4» rl 4 YPCE 6 F�( & Ftrt C 6"FIRE SERVICE SEE CIVIL DRAWINGS - --- - I � 3 FD i 11 � I - 4• r�' `-! -3 `�'"„-` r tcW - FOR CONTINUATION FOR CONTINUATION U 4"SU 3 FD- - - SEE CIVIL DRAWINGS C9 �R� r FOR CONTINUATION I.E. = --3.5' _ �.. /� r F .. SEE: CIVIL DRAWINGS (3080 SQ FT)- ( L�•.\ I i - t. I< 2"V uP L` (2"W UP 4"CW UP C 4"`D ca �'� f735 " 2 I I I I I © 4"SD I 3" STAIR i �� W�{`�'FITII .„ Ii f I.LC; " I.E. I ± I I I.E. _ --3.5' FOR CONTINUATION SD UP I Vii] I „ -� Y�� \3 Fi_L� I (1440 SO FT) SEE CIVIL DRAWINGS I (1180 SO FT) 3"W UP / 4 SD UP I NOTES: I I (1950 SU FT) CTG' (_ I III CTG f `I = --- \' . I __ _" _---_-- _-- __ .._._�� � CI HUB UP 12" ABOVE GRADE. CONNECT TO NEW DOWNr)PCUF. £. FIRE`'�� 1 to _ _- -1, TG 1��? WNSPOL.T NOT IN MECHANICAL. SEE DETAIL 1/P5.1. ! i — - -_� FOR CONTINUATION �;'Q os _,2 3,---- ---- HALL 4" - ( SEE CIVIL. DRAWINGS - ” I 4"SD UP SD UP -- 4 I i � � co (190;1 SQ FT) .71 -_. _.. _" _". _-m.» .,.» »._" .._ ._ .._ .",t___ _ ,._. ._ ,_.. .... .._.. �. .r �. ,.... ._.. FCO I ' 300 SQ FT 1 yam o -. �i o e�r,n IIIffFf��"''���'' ISI"-' _ /�-+'-•-��_ _._ _ _ � _ ._-_-.mss= .._-- _ _.-..-_ _ _-. ..-_ - _ _ - __ _ _ � 9��N O = IL J 16 12 U H 2"W UPJJJ I l I " 4 SD L i 4 I li 2 W UP , FICE I ( 2500 S ;� CTG F CONTINUATION I ( Q ) I OR i 3'ED-1 '{ "- j' I I I I - -' 3 , M ' SEE CIVIL DRAWINGS UP TO WC 4 ( WAITING u 3 CE +_��~:.. �; ..... _�� I 5'- � ,' I I ' I I � 4.,W P 4 j {)4"SD 3 „ . WORK. ROOM I �; �� "FfEALT � '.140P ROOM I.E. _ -3.5' 3 FD_1 - (� I z I - 2"W UP 2 WUl- ; - .- � HAL l_ ' 4"W P V' ,_�HALL �'` �,..,� _o__F_F�IrIE � 41_^ 11 , I I (27300 SO FT) I - � � TO WC TY 3) I t - I I I_TYP. 5)_ 1EDIA1 ENIER _ - - - - �+ � - - - - - -- - --- -� �_�J 7 x'E - - ;, '' j -d,o3 HALL 47W UPFCC, up �— �I IJu 4 i I I MEDIA r I I. � I -- 24 I 3"O „Q 4 LL.I I (775 SQ FT)- — -- _ -�-- _- -- - — - ' --- -- - - - '~ C”) ' ,I I - Ul w M r� I S G 0- CTS L.1..! m O o I i (3910 Q FT) I Z CD I ° CTG 4 CTG , I ' s" I / I I� CSC: � v w I �- -- --- - -- CD 3° �©3"SD ! oc O I I - - --=- - - - -- _ _ -- - - - - - ---- - --- -... - ---- a r _ - --- --- - - - - ----- - - i - —-- = - ( 15 �/ _ c� I.E.I.E 3 5' f-- zp - - — — CTG i I^ CTG TT _ i � � � _., �, , I ----- _ _-- CTG j w Ci FOR CONTINUATION m 3"0 '• C 3"SD 3"�1 SEE CIVIL DRAWINGS j U (/) UJ t. 500 SQ FT) Y J t I ( I I.E. _ -3.5' ©6"W (850 SQ FT) Q (850 SQ FT) I.E. = 193.25' cr- < . i N I 5 — CTG \—FOR CONTINUATION (360 FU) I 5 <L I SEE CML DRAWINGS " " C4 < rC: /CT , 3 �l I �"' w F 4 � - 6"SD FOR CONTINUATION " / (500 SO FT) I ' Q o 4 I W I.E. _ -3.5 -/ 4 % I I R1.1 Y v� (4410 SQ FT) SEE I,ML DRAWINGS I i v Q C� QJ FOR CONTINUATION C 4"SD I IC-) C13 LU o- ~ c� �'W SEE CIVIL DRAWINCS ' N UJ (2125 SQ FT) LU + I FOR CONTINUATION i SEE CIVIL DRAWINGS i I 3 i fi /1 7 ) �) i 227) 6 6 issue date: 17 NOV 2003 job number. 0311 revisions: Al 09/12/03 UNDERGROUND PLAN "' �DELET!ON 12/24/03 PN _SECTOR B - PLUMBING N 7 7 UNDERGROUND _ E PLAN SECTOR B - A 1 PLUMBING I file name: 3494P20B C B L 1 PN N KEY' LAN 12855 SW GRANT AVE ;_14 _�--- P200B 1� 0,12OE3 NOT TO SCALE �'� �12f10j 11115118 90 80 70 60 60 40 30 20 10 A }t � 4'.M�iE'FI. .. . *'A'vC!�'.v.w. .-n•.+M7�14MrR'a!!R!`:r,--._ wi'f�r;i'^.. �:—' Tn!1"•� .+YRIF(6� :..TR.Fr.:,'.R'11Y .rL.�e Jnr ...r�5 .. .M. '/rv�r=n S. -- - - - - --._ .... - - •..�. .. r•...� 'rr-1�. �.., --, -•.�,.- _ �,ea,r^„�*;..... + a, r�.."m�er,� n.,�....�ry� .�mn' NOTICE: IF THE PRINT OR TYPE ON ANY I l t III III III III III t I l i i i III III I T 1 ► t I 11� 111 III 111 1 1111 III III III 111 III I I I I I I I I III III III I I T T�1 1 11 I I I I I I 1 I III III III I I I I I I I III III III I I QI t l IMAGE IS NOT AS CLEAR AS THIS NOTICE, I_—`� I I I_�L _ I L_- I_ _—�1—.I I-61 I I I �L -I -� i � I I ��L -I- I-11�- I I To t t + 3 �oo•S IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT £s �* o� III ►11111111111111111111IIS1I1111�11�,$���I�1111111►11;1�►Il l►�►it IIII►1►�II1I�I!lII�I�II VIII ►�I�t�llll,i�iIIIIIII�IIIII►Ill�f II�IIII►�1��►1�II*1III�II�II1I�!II►��IIIII �I►SII►111►►1111IlIIIIIIIIIIIIIII�T I11111111�1111111ll1llW1llI s =1L11I�1����►NIII 90 80 70 60 60 40 30 20 10 0 N M F r- m c 0 Q M N W fV /�. 0 1 ) i3 in I ' M W © 4"SD I I.E. _ -3.5' a N (2640 SQ FT) _ C 4!SO _ I.E. _ -3.5' ��r,e�� `" (2640 SO FT) ..7 U CTI -� - - __ -- — - - - - --� �-- __ — � — — � C.0002 `� 1U - � FOR CONTINUATION -4'7FOR CONTINUATION GENERAL NOTES: SEE CML DRAWINGS 4"Q 4" 1`} , SEE CIVIL DRAWINGS 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FLOOR PENETRATIONS AND FIXTURE LOCATIONS. ' i t i , CCOOOVVEPED PLAY P F G1N � i 2 V d 473 + o FOR CONTINUATION FOR CONTINUATION 8 N-QT- SEE CML DRAWINGS SEE CML DRAWINGS t Q Cl HUB UP 1 T ABOVE GRADE. CONNECT TO NEW DOWNSPOUT. £. FIRS`' ©4"SD DOWNSPOUT NOT IN MECHANICAL. SEE DETAIL 1/P5.1. � 1z-31� " I.E. _ -3.5' i (D FLOOR 4 SD _ (1680 SQ FT) I FLOOR SINK LESS TRAP. — I.E. = 3.5' (3300 SQ FT) 37W UP V o �'�`•\ CTG TO MS - ---�- :I TG I a N i �s> � �lII �II II tll � I1� �1l� � 11 � III Iln C II II II II III I SD ©4"SD ORA 11 4 D UP I I I ! 1 I W 1 1: 1 I I 112"V I I 1 IIII I r I.E. _ C-3.5 ��. I ��!�Rt� Er� ' ' � I I ' I I " I �''' I --� (1680 SQ FT) L —1 --L 11,J FOR CONTI ATION I I I I i i I I ; I NIU 4TG UPTOPRE-RINSE SINK I I -- III-- WITH GkRPN� A�FOSER � ' " TAG/;"CW &3 � I. III I � iI III � III I " I Ii i I ' � ' i 3"W UP 1 FCO \ HW UP 1 � 3"W UP TO I 1 r/2"V UP I III I I III IIII IIII I I 1, II HAND SINK5"W JP - - 2"W UP ' I PQ LM LAJ L, _ 4 CLOTHES WASHER II I P TO 3"W UP TO MS i " ;�--� � 1 I i I F-- GT-1 11 3� I I `l I I I I Z F W 00 I ! I 3�. 2 _ ' 4 WC..) 4 `FCO I I 1 "V U P 2 C 1 - �-�, ' Q- -7 N "W UP To — 3/4"CW & HW UP TO ISLAND SINK j w N C" - - --- - --- -- - -- - - - -- -P U RPOSt`- _ 0.. Q ' GARBAGE / ' I 4" - ❑ '��J LT7- I I- l.l.l QZ DISPOSER w 3"W UP TO HAND SINK I �I \�I� _ �- ` .r. — — — — — �. .... _. , _.. .,.,_ _ � ." L ..._ _. .�. ...�.� ""J r� CD Q� I 2 CD 2"W UP TO - I V I 4- F- t c�� C/3 UP u-' - - = UP � ' �- � Z !f'' I OFFICESTORAGE _ STORAGE ! I` Z C114 CD 5 5 Q Q a 4IN TO W ! 2 v up —J � ---�– � 1221 j ,,.� � -� - — -- -- U0 � o� cn Q I I I I i I c Q c� n G a. co I LlJ C I. I w 3"SD UP ITORAGE I II I A .,� SSD I I ' • 1.E. _ -3.5' CJ (320 SQ FT) - 1I I I ! I 0YM1\JASIUM -- 4 6 CTG - �--�....t � I I 6 issue date: 17 NOV 2003 FOR CONTINUATION job nur ber. 0311 I SEE CIVIL DRAWINGS + I 'I revisions: GAS METER BY ! 1 FD DELETION 12/24/03 NW NATURAL GAS �a UNDERGROUND PLAN SECTOR C PLUMBING NATURAL GAS MAIN BY ! I I �. P2.0 j 1/8" V-0. NW NATURAL + I GAS COMPANY - 1 4"01 4" 1 I 7 I CTG CTG' ; [J 7 UNDREOROUND ' L - FOR CONTINUATION C__ PLAN - SECTOR C SEE CIVIL DRAWINGS --- C 4"SD Cj 4"Su I.E. = -3,5' j PLUMBING I I I.E. = 3.5 � � I Al (2200 SQ FT) (2200 SO FT) r FOR CONTINUATION , SEE CIVIL DRAWINGS g' file name: 3494F20C- C B PN N 3 r2 KEYPLAN 12855 SW GR ANT AVE 4-14 P2.Oc: NOT TO SCALE PLM2003-00508 - P2mOC r 90 80 70 60 50 40 30 20 10 8 I Mr n't n\ i r• r r \ •r•rnn •rAnn% lona "r n nr ,'---J r-r---i% n%r,% .._..•. .. ,.n�.,.,n.. �......,..•-r -•�...i��n,"dnAWr-7VenAr4 '',tj viV001MV.J4 nnnnl I ... NOTICE: IF THE PRINT OR TYPE ON ANY lr�tlr 111 t1t III .11 1�i ! ! tIi ►11 t11 i r7(r !1rr1 rjr Ij1 rII IT r t 11t t1t ! ! 11t !It tit r ! r1t 11t11rr t y r1t111 ;111 ItlIIII t�`t !!! 11t111 111 !1t1It !11t tIMAGE IS NOT A8 CLEAR AS THIS NOTICE, 1 � _�� _ Lill _ i I i . i 1. i I i �I 1 i I I V�_I I 21 I I -_� �( L 3 IT IS DUE TO THE QUALITY OF THE _ Nosey- ORIGINAL DOCUMENT FAin, II IIII iIIIIIIIi uIIIIIIi iIIIIIIII,lilill�li�Ij�ui iulllli11111�I111 I�illl��l�ilulli�illillili illllli llllllllli illllllli ilillllli III illllllil illllllll IIIIIIIII ltlilllll IIIILIII Illlilllll�` g 111111211111111 Ftll[111111�111181111llll IIII�i�1I 80 80 70 80 s0 40 30 20 10 0 N M r. 00 Z v ( 8) (10 (11 (14)(15) (17) (19) (20) (2 1) (23) (25 (26) (29) (30 (31) N r' C-, CD ( , ! NERAL NOTES �, I I 1. FOR EXTENT OF FIRE PROTECTION SPRINKLER z ZONES REFER TO KFY PLAN. ZONE 1NLiCATION Q o ! I ! ! IS THE SAME AS SECTOR INDICATOR. G- .. I I I I I I � N , p 1 c� 64E i t; (800 SQ FT) -�\ I I I -'*-- ,/"-�"'- 3"SD 1 1 (800 Q FT) t I 1 � i 2"w, v2'cw, i ' i� I ! 11 � I NOTES i 2"V & 1/2"HW III ` I I II 1 UNDER FLOOR PIPING ISSUED UNDER PRIOR UP & ON 2"w, 'h �,W, PACKAGE. COORDINATE WITH THOSE DRAWINGS. ! I I I ! S I 2"V & ?/i HW " „ CLASSROOM UP & IN z 2"W, 1/2 CW 2„V & '/z"HW - 3/4" I J2' UP & DN- a/4' I I V & '/z"HW _ DN P �7 2 I _ _ _} _ -- _ -3/4" 1 3/4" - -- - - - 2 735 1 _ I j FCO f FIRE`�� OtJRCE I I �S 12-31-03 I,I (_,LASSI\0 0M 1+1�1�7 J �,f'.'JM SII I I ! V4 ! 1 V2"CW & 1/2"HW " , " ' I ' I ! I I 1'/2 l,W & '/z H I I � � .o�o i 3 UP & DN -� _ UP & ON 1 w , I ANN I — /4 I w � i77417C� 1 I i� i �a w M �\ I -�1 WC- 2, WC-2 c, ` 2 CW A 1� FDi 4 LE vw U _IT _,; r, i r I , 1 2"CW & /4"HYD --- Wt �I� I i 7(-T / 4 SD WH 1 II I I i I I �7� - -_T--1 & /2"HW I I 1 \I r� i. I I i �, I �� " (2910 SQ FT) - II I I ! I I 'I I: "'�i` '- I! 1 1 1 1 1 1 1 II I 4 SD 01 UP,& ON I _ � ) I II Ili III " II " Ilill II 2910 2„CW & 3/4 HVIf 3/4" ( Q FT �, II ��=�f i_� •-i-�..��— -m � 7"4 '/2 CWj 3/4 '_' 2"V & '/2"HW & DN 185 SQ FT) 3/4 RHW, 2"CW & 1 /4"HW I " T II - 3SD EXPOSED) I;II' 1 1/4"MPG UP I I I OPOSED)5 FT) I 1 �--" z I I I LU - _ - LASS OM I Ch�`SSRC,!_ .? h l I v �, ' 1 1 " " I Al I i � A? „ , " � I � CV I I 2 W 1/x HW = i 2 W, 1/2"C I -3 c� I ' ' 2"V & /2"12 * HW, I " 2"V & '/2"CW j ' i UP & ON I I i ! UP & ON N rn LLQ oS CJ �+ I13/4" I' V = 2 CW." 1 HW �' 2CW, 1"HW 1'/z"CW, 4"W & 2" 1a� �LASSROOM o &. 3/a RHW I & 3/i RHW UP & ON I Ili " -` j I I I - /4 CD � G �Tr?T_T__+.1 1-_ z a `= 1 i y2'CW, 4"W & 2'v '-7 �- I 3 P N _i� I /4" U & O ! F - -----_—___-- __ I UP & ON 2„Cw CW & 3/4'HW 3/4 i cep > 4"SD 1 - i (325 O FT) -- 2"CW w 3/4°HW -� °a- I I °_ '�O (TYP. 2) J S`3 I 2"W, '/z�HW, ! 4'SD 1 2'v & /2 cw I O a LU 5 I ---/4J " 3/4' 2' @ I I B2' '/4' ^ 2„W ON j UP & ON _ I (3250 SQ FT) 5 Q Q 2 W ON WC--2 I I WC-2, cm -- s -�.-- cm _- ---_._ __. __ __ --- T_ 1 I WC- - I 2"W, '/2 HW, {:-- - _..--- -- - -_� LLJ a. ac c� I' ( 2„W, '/2'HW, I 2"V & '/2"CW I I �J �I I - " „ `� I II S C7 Ln UP & DN ” --II UP & ON CW {'' 1=- 00 Lu N 1. 2 V & /7 (;W 3/4 III _., , " I, I UP & GN - - I S-i 1'/z"MPG UP' }/4 S=1 ' 1, ?~�pUrZCt'! �;W, '/i'Hw, ii! I W :;_AS�hOUM 2'V & '/2 CW MPG 2"W '/2"HW �I" - ��� , I I " . M ' 1 UP & CN III 1 " , „ ' HEAD �TAPT II 1 /4 MPG, / 2"V & '/z CW -- :�,u I ,; • WCO 11/2" I 3/4 RHW, 1'/2"HW _ I UP & ON � Y4" & 21/2"CW -K-2 4"W 2"V " 2"W, /z HW,� I 11/2 CW & 1/2 HW S—_2-2 2"V & 1/2 CW 1'/x A L-1!: / I UP & ON !' UP & ON 3/4" 2"W, 1/2"HW, I _-------- 2"W, '/2"HW, 2"\/ & 1/z"CW 6 . S-2 ��_ I " -3/+ I 2"V & '/i'CW UP & DN 6 issue data. 15 SEPT 2003 -- - - ` - -_-- _ ( 5 _fit 2 LW,d 113./4 IW I UP & ON 2 0 SQ FT)SO 01 job number: 0311 L-1 (TYP.2) 4.,w __ _ __- _ __ _ - I _ � � 11 2"W, 1/2'HW, WC-2 & 4"SD 01 ,,, �-- S52 2'W ON 6 I 9 . 2"W DN , revisions: (3250 SQ FT) - i( i , CW 2"CW & 1"HW [ I i & ON I [ ] OF & DN .- I �a 'i L-1 (TYP. 2) - " 3/4" FIRST FLOOR PLAN 1 1/2"CW ON 3/+ HW & 1'/2 CW __- PN N I 1 2" CW, 1-HW & 34- will —_ -- _- __ - __ - _ PLUMBING r II I 11/2"CW ON P2.1A 1/8" = V-0'. IIII K CLASSR(�( M [A^77 2"W '/i'HW, I 4"W & 2"V UP & ON I " 2'V & '/z CW » I I -3/4'RHW, 1-HW I UP & ON 1 j 3/4 I 1 & 2"CW3/47 3/4" -- I � 7 111 I �I j I I i� s_2 I ( I FIRST FLOOR - � I I' I i l l I SECTOR A - II CLASSROOM I `SPECIAL ED 1 - tA, , 1 , I IAiotl PLUMBING " WH--1 ,I 2 MPG, WH_1 13/4 RHW, 2"HW , I 1 ' � fila name: 3494P21A & 2 Y2"CW " FIRE SPRINKLER FOR �- SECTOR A, 1st FLOOR SECTOR A III I , U �� �� �� ��r _ �� �� �� �� �� ate. SECT-0_R= SECTOR B - SEE P2.18 ----_.,,.,,� ..m�.a.. __, _._ 1 t � __. _...- _ - __.---_-..--. _ p SE.TOR B - SEE P218 KEYP A _ PN 2 12855 SWGRANT AVE N 5-14 TIT I� + ii ( i - --- ---`---- 1'1.1120111-1111505 � P2 �I I I I I f I I T I �. III _ _ I � - R III I P2..1 A NOT TO SCALE a 1A 90 80 70 80 00 40 30 10 10 8 "n3494on" .349dP21Adwn xST90RMr*F w7.3494TR.7349411.?'494KP michelie. IXFS,9825F XFS8825 XFSfiEi25F.cth1 NOTICE IF THE PRINT OR TYPE ON ANl r 111 I I I I I I III III I i III III III I I III III I('I 1�T I I I 111 III I'I III III III III I I I I I I I IIIIII 1111111 III III I i f 111 11! V I I I I I I I J I I'! !I I III 1 1 1 1 1 1 1 III III III I I 1 i I iIi4 IIi � I i � 8I -1iib �T(t , 1 -o IMAGE IS NOT AS CLEAR AS THIS NOTICE, _. I _ ------I--___ -___--� — t _ -� �1------ L L--------- -l.___ -�_ —..� I 1 ' IT IS DUE TO THE QUALITY OF THE N.7e ORIGINAL DOCUMENT — III�IIIIIII IIIIII! I IIIIIIIII L!III! IIIIII IIIIIIIII+sill IIIIIIII!1!II!Illi!IIIII sill Infill!' Ilflllllf IIIIIIIIII 111111(illlt(iill(liilll(lilllllill flil�llilfiill'illl�llll Illlllllf Illllllll Illflllll Ifl! IiIIIIIIIIIiIl��I11I111I1IllI 9 Ill lllllll;;illlllllllll[iilllll�lllll�{11� I 1 90 80 70 80 50 40 30 30 10 0 N C,1 c W CTi � z O O CM CJ ► 2?j 1 1--- GENERAL NOTES: 1. FOR EXTENT OF FIRE PROTECTION SPRINKER z ^ b, ZONES REFER TO KEY PLAN. ZONE INDICATION a IS THE SAME AS SECTOR INDICATOR. i-- N 1 o n' (I 3"SC ON 01 u' 1766 SQ FT) Cly 4 t -- FIRE SPRINKLE FOR SECTOR C, �'SD UP 1 SPR NOTES ___ ' N) I I I � UNDER FLOOR PIPING ISSUED UNDER PRIOR SECTOR A -- SEE P2.1A ' _=_�`'--=I— SECTOR A - SEEP lA _ SECTOR a � •� �' ' '�' �� "'� .�... �� `�� '^� �� �� �� �""� "� �■ �""� r - PACKAGE. COORDINATE WITH THOSE DRAWINGS. ►; _. I Tr['� *I Eli '..r �/ c6"FDC` I' 6'F O s' ��/� ECTOR 8=_ TSPR .. . .,PR al'*'I " y " 1IjFIRE SPRINK�.P FOR TATids( �OOR spR-, t"—SPR-- SPRFIRE SPRINKLER UP ?0 SECTQR A, 2nd FLOOtZ 2� 6' FIRE MAIN TO FIRE SPRINKLER HEADER. 2/2MPG, /, RHW, + ! Iy 1 " - - M SEE 7/P5.1. 3/4"HW A 2'CW I I ! I I 2 Mf� /; PoH�d� 211 2/� CW --— -- - I 1 3, - W� 3/4- — ` I e ' -- 2" FIRE SPRINKLER UP TO SECTOR 8, 2nd FLOOR U3 3" WATER SERVICE TO WATER PRESSURE 1 3 r " n ►'� REDUCING STATION. SEE 8 P5.1. -- - / 1/2-HW/CW 'r ' I 11/4 " t x ► II I I iIH III & 3"W UP , 11 3CW 3� � �� 473 2 1 1 " 3"SD �" ' I I I I I I I I f. WC I 1V UP 1 t/z CW DN I 1�/� MPG I 4 SD UP ,I I Ei,.FVAF�. 11,T EC 2 Ifl '. II11 L 1180 SQ FP 1 /�'� : 'bN ►' �y_C�gD /— 4"SO DN EXPOSED) ; q t I I h I I I I 3"W DN /4"PW dN i� (1950 SQ FT) 7M I. W/4 - I �_ --- _ - - - - - - _ - - ---• f. - _ . r.:�.... FIRES SP-1 _ I - -- », i I I �- EJfPIRES IT-77 ,. I 4"SO UP 4*13D DN SEISMIC JOINT I 4"SD UP DEr-1 FCO i 1 (1900 SO FT) FCO " 1/2"HW/CW DN --- - --MPG --------- ___ MPG 2"MPG, y/„RHW, --- 2 4”SD O --- -- -- -- -- - L 1 2"CW & y/4"H"' SPR - - - - SPR - _ CW W -1 - --P5.1 (1440 - - -- _-.. --- -- - - - - - -- - - - ----- 1 - - - ---f- - _ 4 $ " (TYP. 2) ?r y/4" I T r " J. -_- -- - �- ---- -•- _ (2500 SG ) 2�/2 MPG, y/4 RHW, I _ 2"CW, y/4 HW " 2" :FD _J . 4 HW dt 2"Cw ;i i - t. FPI 3/i RHW ,1 _ t.r_ I � a \ 1— I i I I 4 ', F' U-�W, wco, 3 RAGE 1 = '6 �-•- 3 1 I I I X11.. z _; '!(7 K ROOM " 2"CVY ON, I I` RK I�'OCM 1 I -� : ��� �T - --- _ I/z HW/CW DN FF :� I �; L 2"V UP -r-- I y n r 11/4 MPG! UP tEF);A� CENTER I T/2 _. _.. F����i�TION !FALL ,sa 1/2"CW/HW DtJ� ------- �- \ 1 ILS--4-73 111 FCO i TAF( II I I W I i�- •_� �•�_ Ill .I I � . 4 ► I _r C,I;a i 3/4" id] I �' 4 w i , 1 _� I b -cam- _..-_. -- - _ ... .... _ ._._ _ .,_._ .- --__.... — -----.--_.__- -- ---- i I. I - _ �� cnN WH-1 ( ► t I I I -- c� � I II ( N M 4 SD DN ( L I I W w O ! I (1000 SQ FT)-\14' I i I i z CD � I � U � - cr- CD �._.. v _._ �. ��r p� ODN-1 I 1 I 2 t 0 418" 4"SD UP I I = Cr) CM -, eOD UP E5 O �--- I4"OD DN I I m � I I M Q Z 5 ! I I U_ 5 Q w YLA � U ► j I I L� � i I Q G U m C-0 LO 0 o I i I I I W `~J CO NIU e- i t I I i I � I I I ! c.3 7 O j 12) (131 (16) (118) (22) 6 6 issue date: 15 SEPT 2003 job number: 0311 revisions: FIRST FLOOR PLAN �- PN e SECTOR B - PLUMBING N _f C_ FIRST FLOOR - r� SECTOR B - A C PLUMBING file name: 3494P21 B C B PN KEYPLA_N_ 12855 ti�� (:It:�h�' :��'F. (,-I-1P2.1BNOT TO SCALE . 120111-1111508 --(J)N P201 B 90 80 70 60 50 40 30 20 10 8 "0349400" 3494P21B.dwq x;ST20RMEF o:Z3494TB,Z3494F1,Z3494KP michelle CXES8825F XESS825 XES8825F.ObIl NOTICE. IF THE PRINT OR TYPE ON ANY FI�1 I I I I I I I III III III III I I III I I I'I I I I I III III III III III III III I I III III IIII 111 III III III III III !I I+I 1 1 1 1 1 1 III III III I I III III I I I I I I III 11111 11 III III VIII I IMAGE IS NOT AS CLEAR AS THIS NOTICE, I I I I I I I I I I 14 I I I ► I I I I ► 7 ► ( I I ► I � ► I 1 ► I 1� JcAL 13 �0O IT IS DUE TO THE QUALITY OF T'iE No x ORIGINAL DOCUMENT II II II II II - „1111$IlIJI IIIIlIIII!111!11 I IIIlIIIIlIII�It!llll IIII Ill!�'1— � I C n Ir" ii .htsl. ,i• , Ey go so 70 8o 50 40 30 20 10 0 Co CO C4 M v r-_ OD ct c 2 Ca c co W N 2 N 0 3 cn ¢ � Ln oo I ,. GENERAL NOTES: LLJ M ;ls 1. FOR EXTENT OF FIRE PROTECTION SPRINKLER LLJ CD ZONES REFER TO KEY PLAN. ZONE INDICATION IS THE SAME AS SECTOR INDICATOR. C W.f c CJ ,IV- __ __ .__ __ __ O 84 c� N k If! N,r' INOTES _ UNDER FLOOR PIPING ISSUED UNDER PRIOR PACKAGE. COORDINATE WITH THOSE DRAWINGS. •`s EXTEND HTW & CW INSTALLED WITH UNDERGROUND PACKAGE TO SINK. RfD ­)[-AY I 3a) KITCHEN EMERGENCY GAS SHUT-OFF VALVE. - - t I I pRQr 1 2 V r� 2 1,35 I I , U m °Coif. FIr�E5�0 V, , DFIRES 12-31-03 ' I 4"SD 01 4"SD O1 y U : (3300 SQ FT) (1680 SQ FT) - Fes- I F\ W 0 VwOA N N <U N m N N N K i----- -- - -� - �: , 2V UP I I � ("PAGE F5T� II rSD (D TO FD R LER P 3 FIRE SPRINKLER U 3 M }— - ( Q ) PIP VALVE. - _ _._I _' __ _ T 1680 S FT I I t tQ DRY - "'_" L.A C.L I -- 3 W pN f 3'MPG, 1-HTW, �____ _ ' ] I' I 1"CW & 3"V UP SEISMIC JOINT 3/4" I CONNECT I/i'HTW & CW TO FS `t 21 " I -. UNDERGROUND FOR SUPPLY FCO _q Tal'C SPR— M SPR M MPG [ U TO ISLAND SINK, I ---_ 1 1/i'CW & �/ IH1W --- 3/4" I ;�, -� I' 3'/2"MPG, alk RHW I /4 HW & 2 CW -'C —Q FIRE SPRINKLER � I d7 Il FS` FOR SECTOR C 38 27 f II I FD-I Ka I I.LJ 11/2"CW & 3/4"HTW 21 __ � FD c 26 �' G ,;`tJ ' 35 1l 4 LU 3"W UP TO S� I 3 FCG/i'IHTW & CW DN l 4 C.) GARBAGE lc-- I off;, I --_ _ CN DISPOSER 3/4" I — Q -7 CV ,. —� *-+ GPRV-3 I I 23 2 II 180 MBH- - I _ J N � -- - _`___-'SIJL1'rPLJVpQ5>L`. _ - - - - CL u�il z 3/4"CW & HTW DN I/i & CIS UP �- - [� 7 _= L..L.� O -- ;.e. LU w Q _ - 3/4" — — f .� I _ - r , c DN �� 1 CW DN y -Y �. I I 3/4 G DN -- f o p F= FCO r J � -- - - �� 2"V UP�- >n] _ C/3 LU 11/2"CW & 1/2'HTW DNI,, �f C�`71 I i�i GE I i I Tti1RAC�= 6 �\ l ' I I 20 5 Q Q Q 5 „_ W - J I Q - 2"V U'P ; - I ail z C-3 ~ 3: 11f -1 o W cL Q " W CN LL , \ f ( LL 3"SD UP °' _ _ M �I _ -1 r< 6 DN 1 " 6 issue date: 15 SEPT 2003 Q 3 MPG DN i I (320 SQ FT) Fnl ; I \. J' I \` I ' l job number: 0311 WH-1 GAS METER RATED FOR 5148 MBH C revisions: AT 2 PSI DELIVERY. CONTRACTOR SHALL CONTACT GAS COMPANY AND COORDINATE INSIALLATION ,Iw OF GAS SERVICE AND METER �• FIRST FLOOR PLAN - PN PAY ANY COST INVOLVED. PIPING _ 1_ ___, UP TO AND INCLUDING GAS METER SECTOR OR C - PLUMBING N r,r INSTALLED BY NW NATURAL. - - -- --- -— I m ] I1` 7 FIRST FLOOR - SECTOR C - I , ) A PLUMBING MRIM l file name: 3494P21C C B PN N \1 r •`;� 2 KEYPLAN_- __- 12855 SW GRANT AVE 7-14 - P2.1 C NOT TO SCALE P1,N12003-011508 P281 90 811 70 60 b0 40 30 20 10']� 8 ;'03 "0349400" 3494P21C.dwq x:5T20PMEF o:Z3494TB,Z3494F1,Z3t94;f',L3494KIt,Z341i4K_11 michelle IXFS8825F XFS8825 XES88251.,_tl 1 OTICESNTHE PRIOT AS NT CLEAR TYPE ON NOTICE,ANYIIIIIIi Il Ilt III tl1 Il,illi tliilll Milt ilt T�(I�I !ri lii f �l�l I(IIIIi Il, III ISI-Ili II�IIi Ill Ill lllllll ill III I� Ilillll til I I Illltll IlT�lll lllllll III I 5 � I ( I IIIb I � IJT IIB -iI- I :- - aJ-r ,►� 13, �ao -�- — - IT IS DUE TO 1 HE QUALITY OF THE _ No 7° �_ �" ' - -- - ORIGINAL DOCUMENT L 8ZLZ eZ 9IZ bZ 68 Z i 7 UL �i 9t Lit 9t 41 1rt St Lti1 at e I L 89�11 llliill llll IIIIIIIII IIIIIIIII IIII IIIA IIII►i►I►�11111�11� IIIIII��Ii►l�lll�►�IIIIIIIII ,Ili 1 IIIIIIIII IIIIIII����IIIIIIII IIITIIII III�IIII III 1�����1�1111�1 II►I I►I Illlillll►�li��lllll►111111 ►1111 lllUlllllllll lllllll�111�Wll1�I�lIlJ1l�I�INIII cr 80 80 70 60 50 40 30 20 10 0 1 (8) 10 11 (4)cip) (.171 19� (20 (21� (23 r 1 �. .� .2� 25 (26 x,29, �30) (31) l � GENERAL NOTES: 1. FOR EXTENT OF FIRE PROTEC1iGN SPRINKLER ZONES REFER TO KEY PIAN. ZONE INDICATION IS TH;_ SAMt AS SECTOR INDICATOR. 2. PROVIDE HOSE BIBB HB-1 I BELOW LAVATORY IN THE I l I FOLLOWING REST ROOMS. A207, A208, A211, A218, 1 3"SD UP I I �� A229 AND A230. I , I i f I ! I � 3"SD ON I (800 SQ FT) I I ASO DN ; ' S_ -2 I I I ! (800 SQ i I II -� CLASSROOM l LASSROOM I LAz r ^s t I F I I I L__ I _J V� GIN-0 G -t- "'" I 4� b 4735 2"V up 1T_..LLI- �_ LIl�� 12"v UPFN� N I 1 ! I �•O.n 'ter 23. . �� FIRE`�U I ( I I CIASSR00 RESOURCE CLASSP40M I I xautes l2`, o� EA i I I 1 - _4 S'V UP 4"S UP--.N I C` _ ; ]. �-1 II -4"S UP I JDN rA 2 ,r� j M ; 3 DN � 4"SD ON J _ STAIR ( ISTAI R 2 (2110 SQ FT) I 3"ED- I 3" - ' �_ _ :-- I I I47SD ON I I 1'v, v1' ; II 4(291 5Q FT) 3"S -U i I 1 I` -3"S UP I I —_� I 1110 3"SD Di _ t 185 SQ FT) l 3"SD ON -- EXPOSED) r i I I 11/4'MPG �N 185 SQ Fr) I I II EXPOSED) I LIJ I it I CLAaSRO�OM ' CLASSROOM E�j 4 A2, I C2a I V II I M i I 04 I i 2wV UP ( I 2"V UP- - ; I ; ill Q N rcIN CM z o CLASSROOM I I ROOM I, 1 � J F- CDw I:LQ'S`: I .__j U .• i I ® t.a f~ CD ' Z -- - - --- -- -- - p n c, -- — _ — - ---- ---- - — r� I 4"SD ON I I � I I � s (3250 SQ FT) -4"SD UP I �' I -_- 4"SD UP 4"SD ON cn cn U 5 I I 3110- I W �) Ie piI l C=1 "II' D �, (3250 SQ FT) Appro:od. ��tYl!l t OF Tn .RD.......fI- - /. ij'i,� ih. ndilionallyApproved.. . . . .......... I 1 LAJ z I RD I fironly the yLQrka descidtn _ S 5 < C7 a S[9MI NOS �.�1"�✓.....� S Q C+� J......I a L— U I G see _a,tor to:Follow• [ 1 � l I I j I I j �yq.ad•ire �: �> ::, H cL o 2"V UP _ _ r- UP S- I ! �'A ___- �a,� _ _ �r L.l J 13- TV s cn 3 V UP _ I - 3"V UP ! -� `t o ` ' I 2 Ln S-1 �l 1t/z"MCO PTYP. 2) (TY P. 2) I;; I -, I L ~ f f! GN _FrI f; L.1.J 1 I OFFICE 1! ASSROOM lF UR'"- I RESOURCE II - r''I_ASSCOOM l . ` ,_" LAS , - f MS-1 1 /z"MPG UP-� i' FALL --� � + I •�� 6 3!V UP ! I --- 3 V UP . r ._„ I _ I - -- _---- _ 3" _ RR �.. 6 Issue date: 17 NOV 2 � R D_1 �. I l --_L------ ___.- R j©b number. 03 4"SD ON ! 2"v UP ". I ! B) ,-� I P D j ravisiorls: 3250 S FT _ • ,� ( 4 ) 4 SD UP DF 1 - - - - - -e l " "SD ON l n� � L_ ` L � 4 SU UP I (32 0 SQ � _ Al AUDI N 10/2/ �P. 2) I i\ (TYP. 2) I 1 eP2'�)A SECOND FLOOR PLAN �� I��IFTI(1NSECr OR, A PLUMBING -PN N CLASSROOM - CLASSROOM + r I Inzi z F r i _ 9 I f 7 2"V UP 2"V UP---/ i t + ( I I I 7 SECOND FLOOR - I SR Q CLASSROOM SECTOR A - _1 AI L ' PLUM; . G 1 FIRE SPRINKLI(R FOR I I l filename: _ 3494P7,') 4 SECTOR A, 2 d FLOOR I I B EIRE SPRINKLER DOWN 1 �' SECTOR A - ~-"- _ PN SECTOR B - SEE P2.28w wAAwAw� +..n.� �A�r� wrr rr��rr- __.: .._. ;---- --- - - - - - -- - --- SECTOR A `{ N 1\��'PLAN " r ( - I I l �.._.. _ arrwv wY..w... wwrwwwwn wwwar �r � �r 1�� � I � G SECTOR B - SEE P2.29 NOT TO SCALE -- - r213s5 ti'►, l�R.\1 I' :�� 1'; !i-I l I I I I I I P2 2A 14.11200. 00_us P202A g0 80 \_.. �, . , , , ,.,,n ,,,,,,, >,.,, rrrn ,, 70 60 50 40 3Q 20 10 13 f`.1...It rAnl n. 7An A nn')A _ .t•l�,nnllrr -17 An Atn /7AnAIM-77AnAt-'� ._..AL rvrroonc vrroo,rt- AL nnnn, -,,.,. ,vy+.4•i,lliily.:.a,ihy.Mw.. NOTICE IF THE PRINT OR TYPE ON ANY II'I L I I! III III III III III I I t 1 1 III III I I I I I III III III III III;I'I III III III III III !I I III I I III III III III I I f 111 111 161 , 11 111 I 1 l 1 I I I l I Ij I IIT III III III I I 1 I I 1 IMAGE IS NOT AS CLEAR AS THIS NOTICE, L I 11 I I L"-L_ ��I 1 ��-I-I 164 I——_- I I I S_1__.I I I I I I 1 I I �J �C ti L 1 3 1 zo 5 IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT - I1111 I111�IIII�III1 IIIIIIIII IIIIl111I�11111 4144444:I I�IIIIIIIII�IIIIII IIIIIIIII IIIIIIIII II�� IIII I�I111111 IIII IIII �I���li I IIII II�IIIIII�IIIIII�II IIIIIIIIIIIII�IIIIIIIIIIIIIIIIIII!IIIIIIIII Illlll�illl L �l;U 11111111 9 LLli y 1111.Il 1 L 1144 IIiIINIII 90 60 30 80 50 40 30 20 10 0 0 N rr w rnCal v. Z O v N' co w (�! W cr: N F C, }yJ C 1/71 g � GENERAL NOTEScn: 1. FOR EXTENT OF FIRE PROTECTION SPRINKLER z I ZONES REFER TO KEY PLAN. ZONE INDICATION a INDICATOR. C IS THE SAME AS SECTOR r- ; H N A - - I cn CD 3"RD--1 Ln (1386 SO FT) c`J N F-- ' 1 I 1 1 NOTES• � 1 I ! CONNECT MPG TO GAS REGULATOR I, __T_ —,_ I _ 11 PROVIDED WI fH UNIT I ! SECTOR A - SEE 2A ' r' i. SPR SECTOR 8 F!� RI�VI�L F I �_ ( i FIRE SPRINKLER DOWN EIC R k 2r( OR LU. / STOR TF— \� t ns 2"V1UP & DN �'SO ON " AlR 1 :.LE` UR - ' EIEC 2 473•. I FIRE SPRINKLER FOR Ly , -r SECTOR B, 2nd FLOOR I 4"SD UP N I I I _1j I i u - - - -- - - -----— f. — " EITUi31- ES 12- 43 IR SSD DN �� I _ - 4"SD DIN 4 (_ �l s i ! �� (1950 SQ FT) 1180 SQ Fl) I 4"�1 I (1440 SQ FT) „R�n-1 EXPOSED) 4 (1350 SQ FT) (1900 SO FT) IN IN, .0 KU-3 O� f I I na I m _ -- S VTR t EF-6 3 — I ® ACCU-1 EF-7- 3 No 2"VTR 1 •� - - EF-4 l � r] 2"VTR —�•- ..pp 4' 1 r I _..._._ S.__...t •p'. n__ r-F-..F -- Fasa�i_ "1 sC{f..�..,a _ • _ 1 /4' MPG FROM BELOW i 1 } ` (400 MBH) T,) W "'• I I I j I i Ij I I 4 f ! I I 1 4 LU C) , Imo. N Q7 CL 3"RD-1 (1000 SO FT) I v w _-r L =ill I I -1--- -- •--- I _-r-•=•+ --�- - •I I �' _ _ -V 1 Or/� CC CD i moi^ 1 = Z a F— 15 i C/) 7 LLi 5 Z LU N 5 Q CDQ z o NI W Q v o < LDLn UJ W 4 LL. 7 , '12) 13", 6 6 issue date: 15 SEPT 2003 job number. 0311 revisions: I SECOND FLOOR PLAN - PN SECTOR B - PLUMBING N I i 7 SECOND FLOOR - SECTOR B - q PLUMBING file name: 3494P22BI c I PN z KEYPLAN_ PLAN N 12855 SSV CRAINT AVE 9-1.1 P2.2D NOT TO SCALE----- --- I'LN1200.1-00508 -- - P282B 90 80 10 60 50 40 30 20 10 8 r'n'4940(1" 3494Pi9R dwn r5'qf1RMFF n•73494TA 7.3494KPJ3494F? michellr fXFSRI175F XF'SRR?S XF;AR95F rthl 1 NOTICE: IF THE PRINT OR TYPE ON ANY If11IfI�IIIIII IIIIIIIIIIIII III �III� ILII 1 IIIIIII Illlllr Ilrlllrlrllll IIIIIIIII�IIIIIi, IIIIIIIIIIIII IIIIIIIII�IIIIIIIIIIIIrII(IIIII ItIIIIIIIIIIII II�I�Ilillll�lllllll II1IIIIItIII I 5 , IMAGE IS NOT AS CLEAR AS THIS NOTICE, -I -1l - �1 4�----- �- - L . -- b� ! 1 - —1 --81 !! �I i0 11 l�l TCT. ; 1 13 QUO IT IS DIE TO THE QUALITY OF THE _ _ _ __ No ORIGINAL DOCUMENT ((� r� 1111"111111 III1g I1111I1ll IIIIIIIIIIII III IIIIIII', I�IIIIIIIII IIIIIIIII IIIIIII IIIIIII ',,IIIIIII IIIIIIIII IIII IIII IIII IIIIIIIIIIIII IIII Illl IIII�IIII IIIIIII►I�III�1ll111111�111111111I1111 lll11211111 s lllllllllllll!NII ` y I. i. ;9 j l aR I�Ii.9f i;.10s f go 80 70 80 60 40 30 20 10 0 LO c) rn ao rn Z O v � N W � � N � 1 � ( 3) i t z I W O F— N I C/) N -- - - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - --1 � cn � o Ln I I - ' I I I i I I I I ;OVERED PLAY _ I I I 2 V 47 ft 2 I I F or 23. 4 cn f FIRES��� a EXNRfS 12-31-03 I 1 - DRY PIPE `� I GPRV-B1 SPRINKLER SYSTEM FOR 4"SD DN 4 SD DN � (3360 SQ F [[te�rr T) (1680 �� I I) y y N N p --- COVERED PLAY AREA 4"SD UP I N _ /-G-PR-V-T2\ � I I I �-�- ' 2"V UP ! 4"SD UP' 2'G DN 3 9 ;\���.._ I 51 1 1/a°MPG I' - DRY PIPE_ ET--1 DN 4"SD DN I V— GWH— I' (1680 SQ FT) 1 3"FD-2 3"FD-2 �L a 1"NPW TO 3" 1"CW/HTW DN - - _ - - -- BOILER MAKE-UP _ —— 3"v I 2"V DN w 1 CW DN 3"MPG, 1"HTW !I z & 1"CW DN I I W I M1„ � I 4 W 4 c " I ( V ry N 1 /4 ( " Ili ___3 N I I 11/2MPG UP J N r- wCL 0 11/4"MPG UPJ ! I' �"!.� z 0 i) v � I I w 0 = a MPG 2"V UP L) v 11/2"GVTR i --r = I 0 LU 2"V DNR�_� �-- C° z a i z 2"V UP I I fix, I j j I I 5 Q 5 _ I I I i _ L --- �"" 0 L7 -- f c Q CJ Lc N J II W , I f ► I - (320 30 FT) I —! I 6 issue -late: 15 SEPT 2003 I I : job number: 0311 I � I I + ravisions: I I � SECOND FLOOR PLAN - PII N SECTOR C - PLUMBING i r i I �m SECOND FLOOR - 7 I N SECTOR C - I I A PLUMBING file name: 3494P22C C B __J L I I F'fJ I. t ('3) 2 KEYPLAN5 _ N .. _.• -- 1285_-- S��'GRANT AVE IU-!�t (, 2C P2 2C NOT TO SCALE P2 PI.f112003-IIOSUB ■ { I 90 60 70 EO 50 40 30 70 10 8 I 'o "0349400" 3494P22C.dwo x ' T20RMEF o:Z3494TB,/ 494KP,Z3494F2 michelle (XES8825F XFS8825 XES8825F.ctb) . . NO'10E: IFTHEPRINTORTti'PEONANY rillIf IIII�IIIIIIIIII III�I i illllll IIIA I IIIrIIflll'flTlTlllllil IiIII�I IIIIIII IIIIIII IIIIIII Iltliflltllll'll 1111111 I�r�T1t tl — I %101111 111 1 1111j1�1T111 I I�IIIIIIIII I I i lI II 4 15 I g 1111111111111 I IMAGE IS NOT P.S CLEAR AS THIS NOTICE, ----� J 1 � IT IS DUE TV THE QUALITY Or THE 9 NO'N 9Ills SORIGINP _ DOCUMEP'T tM11- l l_llliii6iliiilllillilll!l Tlllliiillillllllillliiii uliliiiiulllillllllllllulT _ iT�ul8llllliu 11111611 1111111 11 E�I �IIIu�Il�lul►ue� I 1 'p i' S1 00 e0 70 60 so 40 30 20 10 0 y 9 o N cn i Q1 Q (8) !1 Q) (11 !14)(15) (17� (19) 120) f 21� (23) (25)(26) '29) (30) (31) LD N i I o "' ! I I i GENERAL NOTES: Z 1 i W I N i cn I I I I O ILn 7 N F-- 1 ' . A,) 3".RD-1 I (800 SQ FT) 3•RD-1 NOTES ! (800 SQ FT) ! I U1 CONNECT MPG TO GAS REGULATOR I i I j PROVIDED WITH UNIT. I ! j ! I 735 I TVTR l ! , MR N I V • ��� 23,E 4, FIR I I i P TR ' j 1 i I l Accu-2r I , , 3 3 - (291D0 SQ FT) -�_'_ II J� -;- ---II � 40RD-1 4"R -1 - -• --- 910 SO F A ywl, -185 S F7 J3 1 ( Q ) (18B5 SQ FT)RTU-1 11/4"MPGFROM BELO ( _--� ;i I W (313 MBH) J ! ` — LU4 - _..._ _ __ _ __ ✓ 4 IJ cn ! -7) � N I W w z o IJ � F— w - 2"vrR !— 2"vTR L J J cc O O LU 1-- 0 Cn p ct I ( I r -� _ _ - F C� c� O i I 1 w 4"�-1 � I..rJ L.J I. ! --I�-•--1 � (3250 SQ FT)- I - 4"RD-1 (3250 SQ FT) < w z 5 5 Q C� Q Q I•____ 1—� -')*VTR ' LL Q cn III !l •\\ 2"VTR --- ;-=-; ,� � � RTU-2 3"VTR 'I" 00 LU CN W 11/7'MPG FROM BEI.OW (625 MBH) L.L. , 8 issue date: 15 SEPT 2003 VTR 1 number. 0311 job 2 VTR 0 revisions: 'LJ ' 4"RD-1 i 4', --- (3250 SQ `7)- _ ® I 4"RD-1 ( - I ( -; _ 1Ir (3250 SO FT) ROOF PLAN — PN SECTOR A PLUMBING l i ! j is I _------__--- J � X11 2"VTR L_ �- 2"VTR III � f j I I � ROOF PLAN - ( _� it SECTOR OR A - �— A PLUMBING - _ - - -- -. ! ! I I I(! file narne. 3494P23A I cPN 7- M B i 12855 SNN'(�ItAN'F AVE 11-14 SECTOR B SEE P2.38 I SLIM 8 - SEE P2.3B P2.3A NOT TO SCALE — 111.M2003-00508 W' P2r3A 90 80 70 60 50 40 30 20 10 )' "0349400" 3494P23A.dwq x:ST20PMEF 0 Z3494TB,Z3494KP,Z3494RF michelle [XES8825F XES8825 XES8825F.ctb1 _ NOTICE: IF THE PRINT ORTYPE ON ANY Iflrflll II�Illllllllill VIII t tilllllllllll illlllllflllTlf�rilll'I�Illjlll II�Iilllilllill!illlllllilllilll�I�Iilllilllllll !!II�flTil1l�f�fLlIT�III�II111�� 1(Irlli�lltf �II�I!Illllil l a 100 IMAGE IS NOT AS CI EAR AS THIS NOTICE, L_- I 11 I _ � — 41 �L -- g1 _ �1___ ---�L I �_I—.-_i--1 -�L J IT IS DUE TO THE QUALITY OF THE _ _ _ U11 _ _ _— N"MORIGINAL DOCUMENT � 8L LG 9E L ►L � iL� 8t 8t L�[ 9t 9�1111 �i! !! ,ll III111111 III. IIII IIII ill► IIIIIIIII IIII IIII IIII�IIII III! IIIlllll Illilllll IIII�IIII IIIA►III IIIyIIII IIII Illi II!I�IIII III.W l l,ll Ill�lll 1 1►lliNll i d�7? tF I F', ' i i 80 70 60 50 40 30 20 10 0 I i rl� ; cmM Ln 1l C) C C_ N � n L Z r a C. C/) N N N inO C ✓ N C.0002 1— 1 RD 1 I o i �.! SECTOR A - SEE SECfO'A_"� SEE P2.3A im W ■ i I SECTOR B -� I ! SECTOR B 2"VIR 2 3RD-1 _ I 4795 (l 180 Sr, FT) (1440 SQ FT) RtGON ® P � f. FIRE. r� I - II II�I!:T`•r_�--__—---_.—� -___..J ll.-�Lr��_•..•r--III�-_r—�_' .I�II IiI I`IIiI�II— �`\II�i►!,IIII, iI,I'I,! I I,,II i I �II�i� I1lIII(i I II�i,IIIII I I' ANaE!p� —Ii I�IIIiI ,�ISI _I I�III�iIII' TatII-I` I 03 7 r to R4 RRD 33 ' W 44 wI�ZLLJl-- -l■I- --- CL zcUZQ; C'14 M c:)C�GO.`-rCY2io CD OD RD Q 0 LQ Q co c)_ c : C/3 `A •= ao WN CD C> W LL 7. i ?. 6 6 issue date; 15 SEF-NN aNN 2003• job number: 0311 revisions: ROOF PLAN P" SECTOR B - PLUMBING 7 ROOF PLAN - IIiI ' " �I.7L$_IiIr�I—LII�I'�i GII II 'II IIli Ii i ill II(r-�'_ijt . - T�T�t�1t��iiJtI-x-11�111�t�it r(t Illt IT1-11I St�jTt�-ll-St LITIII I�t-tttIi_1�1�,.�wtTwlrtslntgEl�-r(rI8.tlTll�7iIyl1tjllL�tlt II9I�lUit li9jtl..r.lt';I 111�II81I�I IlwtlL tli I IIT,eI1mD u��I 1 rn.. .��w�rn+.Q„/r.V..L.. ( .:,.,,.a+u,��+�m:•.� ,rM+�F_ruElu�.. N SECT OR B - A PLUMBING file name: 3494F23I3 B PN D2KEYPLAN 1285;NOT TO SCALE P1,i112003-0()5118 12_Ii ■ 13 90 80 70 60 $0 40 30 20 10 8 Ik1:,, 3 U.4�4UU' 34y4 /-d.dwy A:�T2QRMEF o:Z3a84T8.i44J4KP.Z3494RF inichelle IXLJ8825F XL58825 XES6825F.Ai r�T[IfllrllTt7IT 4NOTICE IF THE PRINT OR TYPE ON ANY IMAGE IS NOT AS CLEAR AS THIS NOTICE, 31 100 TJ No 98IT IS DUE TO THE QUALITY OF THE ORIGINAL DOCUMENT IIII d 6 TSLlll6�ltllll�llLllF11111111911ti- 0111,1, IIIIIIIIIII�I11111 '1111111111_ IIII�IIII lill�lllllllll�llll ll Ilillllllllll�llUllll�llll Ull►tll WWII III uII�II�IIrl�llll IIII�IIII Ilullll�llll�lkll , + 90 80 70 60 50 40 30 20 10 0 M m 07 1 O CO 1 1 r"r w N Su � 3 � o ItIIII�II11I1 l I(�I i II jiI I II II I _�1Iit1III I I,�l►!!ii i I!!�II -III!I jI II I(i1I'I I'I�I!I I _--I�iIIiiIIIIi �III;!I��!iIt I TI�IIIi II II T1iIjI I`'- �jiII�1iII 1I�!iIiI_1IIl—I�It!I I�lI`I(Ii l� .L��IiIIl�I.iIII —I;i1 i•, ,i1jIj�Ii IIi!I'(I I�I,I 1 It!!I 1i iI;t�I!�►', IlIIIIj r—!I�I!I I j!IIII!-1_1II_�I ;I1 lII1!Ii! I;I iii�II tI i lr—I I1i�IlI1'l�iI!?J_iIII,I!I1j IIII I _-.— --:- — -- lE�N �S /-) cn WQ/pC 0 cn CD CN N NOTES 01 CONNECT MPG TO GAS REGULATOR PROVIDED WITH UNIT. P 2 473, z i EF DIPS 12-J1-03 2"VfR 4MRD-1 (3300 SQ FT)60 SQ FT) FF-13 3 FF-83 3"VTREF-9RTU-4 11/2"MPG FROM BELOW -7 '1 4,,, U11 (500 MBH) 11.4 LU ( 11/4 MPG FROM BELOW (250 MBH) LU .- �11 ~ LU 2VTR EF-10 O LLj C? 5 (7 a < 5 � C-3 r � LUaLom LU N WLL. RD 6 issue date: 15 SEPT I mNf� 2t- 0J7. 0 03 6 job number. 0311 revisions: ROOF PLAN N N,ECTOR C _ PLUMBING ROOF PLAN - 7 I SECTOR C - I � i 1 .-...,.M,.. ! 1 (IIII III'IIIIII I1 II�II II1 II IIII rrIIII�II1II IIII�IIII 1IIII (III�IIIIII IIII IIIII (IIIIIIIIIIIII�IIIIII IIII l(IIIIIIII1IIIIIIIII�II (IIIIIIII1IIIIIIIIIiII lilt IIIIrIIIII IIII 1Ii 1 I I � t� If llI 1 I1 TII 1N11 1 o PLUMBING ( 2 ) file name: 3494P23C FN KEYPLANI�gg5vWCK� TAVF13-14 N 141111103-11518 P2m3C P23CNOT ?0 SCALE g0 g0 70 60 50 40 30 20 10 8 JJ ,'03 P:\CAD\Drawings\3000-3499\0349400\ 3494P23C.dwa x:ST20RMEF o:Z3494T8,Z3494R1 michelle IXES8825F XES8825 XES8825F.ctblNOT:CE: IF THE PRINT OR TYPE ON ANY 1III !1 l I11r11r1T4 I "T Il[T (IlIjIIIIIIIIIIIIIIII1III(IIIIIIIIIIIIIII ill !111111II IcUU6 glto Jo13 IMGE IS NUTAS CLEAR AS THIS NOTICE, 1 �1 �1 - I IT IS DUE TO THE QUALIT'f OF THE """ Il ` ORIGINAL DOCUMENT 0 [ [ Ell Ztl 51 1 11 IIllIll 1 III1 lli 11111 d 11T -1 ]i4 30X 90 80 70 60 50 40 30 20 10 0 N M n p LS1 V Z U wr WIC-4 N r C M Zai q 'r _7 Ln ll cn CL M I � h I Z W p -2 PSI GAS CN a C 2 PSI GAS i�- TERMINATE WITH TURN DOWN TERMINATE WITH TURN DOWN - ELBOW AND BUG SCREEN N I I ELBOW AND BUG SCREEN ' MPG— �� o �n -SEE FLOOR - I MPG SEE FLOOR - - - - -- i- C/'2 ,n , _ PLAN FOR PLAN FOR - - PIPE SIZES I ASME TEMP/ PIPE SIZES 1 I -ASMI TEMP/ I PRESSURE PRESSURE 3/4" " is RELIEF VAI-VE RELIEF VALVE I HTW I r WATER HAMMER -'F HW _r I[: I ARRESTOR-- I I DISHWASHER D5 I I THERMOMETER- 35 -i I j PRESSURE I I GAUGE - W/BUILT-IN I I GWH,2 BOvSTER WH-1 —.-, DEf_2 I HEATER -- DET-1 GAS ► STRAINER GAS --' I COCK BALL COCK I VALVEI GPRV-2 I GPRV_1 --- I PR J u J Vc� p1N 2 - T�' �_�OR I 2 OIf:GO 1473 - - - __ - - - TO FLOOR I I DRAIN I I---1/�- 3/4"HW 149 PRESSURE �-INDIRECT WASTE (IW) DRAIN u � � FORUM SYSTEM REDUCING VALVE, FLOOR SINK HOUSEKEEPING PAD - HOUgEKEEPING PAD `�E. FIRI:�'���� SET 0 20 PSI CONNECT 3/4'HW TO DISHWASHER EXPIRES 12-31-03 VERIFY REQUIREMENTS EXP DISHWASHER PIPING - 3 W/ BUILT-IN BOOSTER HEATER 2 GAS WATER HEATER DETAIL _ GAS WATER HEATER DETAIL_ y y N N N t iO�NN SCALE: NONE y P5.1 SCALE: NONE ANN ! SCALE: NONE P5.1 a .. is q 3 FROM WET SPRINKLER -� SECTOR C Y q \ VACCUM BREAKER 1/2 HP AIR COMPRESSORPw W/ESCUTCHIONS PIPE MOUNTED O e ELEVATOR r ,,LOBE VALVE SHAD CEILING - SOLENOID VALVE 2 T FLOW SWITCH OS & Y VALVE u/TAMPER SWITCH F CONNECT 1/2 TO 2"W s R FLOOR FLOOR DRAIN Z DISPOSER INLET 1/i'CW START STOP DRY SPRINKLER 1-1/4" W / SYSTEM COVERED 4 SWITCH & TIME PLAY AREA �- - - 4 LU DISPOSER 27 1 DELAY RELAY UNION 10 GPM DISCHARGE FURNISHED BY KEC SHUTOFF VALVE 4 J SHUT-OFF P --- CV 11/2'P-TRAP INSTALLED BY ELEC CHECK VAVLE c? PTES CM NO VALVE FLOAT SWITCH S_1 1 �S c� SUMP -- 01 FOR REQUIREMENTS OF LOCAL DISCONNECT. W 1 EQUIPMENT FURNISHED BY KITCHEN EQUIPMENT CONTRACTOR, INSTALLED CD SEE DIVISION 16. I-- w BY PLUMBING CONTRACTOR. DRY PIPE VALVE `� v 1r t2� EQUIPMENT FURNISHED BY ELECT. EQUIPMENT CONTRACTOR, INSTALLED W/PRESSURE SWITCHES J oe O BY PLUMBING CONTRACTOR. Q cz o Q = z o 6 DISPOSER PIPING _ 5 DRY PIPE VA' LVE DETAIL _ 4 SUMP PUMP DETAIL U o P5.1 SCALE: NONE P5.1 SCALE: NONE LJ P5.1 SCALE: NONE m, � �- z a r, 1= 1- 5 5 Q a O H C-D 0 Z a a W � Q � O O O L N 3" J TO SYSTEM----' I K 1" � W ® BY-PASS FLOW SWITCH F F F (np.) � PRV-2 I FIRE DEPT, 2/3 FLOW TEST STATION (TYP.` /-OS&Y VALVE U I REGULATOR WITH TAMPERS V PRESSURE P,ELIE SHUT-OFF vAL,:. SWITCH SET 0 125 PSI 3' �~ S S S S (TYP.) 2" TEST/DRAIN 6 STRAINER (TYP•) 6 issue date: 15 SEPT 200 TO FLOOR DRAIN 2" 2" - UNION � I , DRAIN job number. 0311 /-PRESSURE GAUGE i i VALVE revisions: Ii W/ GAUGE COCK DISCHARGE TO OUTSIDE HARD SURFACE 3" 3"WATER SERVICE i 1/3 FLOW ® 107 PSIG -.-- FULL SIZEREGULATOR FULL SIZE DIRT LEG u S LINE STRAINER FLOOR `- MAIN SHUT-OFF W/TAMPER SWITCH PRV-1 = 55 GPM OUTLET PRESSURE SET 0 70 FDC PRV_2 = 110 GPM OUTLET PRESSURE SET ® 65 FIRE MAIN NOTES: 1. FOR PRESSURE SETTINGS AND FLOWS SEE SCHEDULE. GENERAL NOTES: NOTES: 7 DIAGRAMS - 7 1. FOR ZONE BOUNDARY REFER 10 KEY 01 FIRE SPRINKLER MAIN FOR SECTOR B PLUMBING PLANS ON FLOOR PLAN DRAWINGS 02 FIRE SPRINKLER MAIN FOR SECTOR C 3� FIRE SPRINKLER MAIN FOR SECTOR A FIRST FLOOR ® FIRE SPRINKLER MAIN FOR SECTOR A SECOND FLOOR file name: .i494M62 8 WATER PRESSURE REDUCING STATION _ FIRE SPRINKLER HEADER P5.1 SCALE: NONE - - --- ---- —`--- - "�_-- P5.1 SCALE: NONE 12855 SNN'(;RANT A%'E la-la Pl N1:0113-1111508 P501 90 80 70 60 50 40 30 20 10 8 !03 PACAD\Drawings\3000-3499\0349400\ 3494P51.dwa x:ST20P.MEF o:Z3494TB michelle IXES8825F XES8825 XES8825F.cihl NOTICE. IF THE PRINT OR TYPE ON ANY (I III III III III 1 1 1 III I I I I III III I I III III I Il III I I I I I I I 1 1 1 I I III III 1 11 III III III III I I III III III I I III III III II VIII Ili I I I I I I III 11 1 I I I I I I III III VIII I 9 _ 1 SC�,v� � . TUU IMAGE IS NOT AS CLEAR AS THIS NOTICE, L_ _...__I�.�1 � '_---�I I --4�.-- —�L---- --- f l � I - !1 --�—�------� 10 11 3---- __ IT IS DUE TO THE QUALITY OF THE "°'® ORIGINAL DOCUMENT [o(E 8L I B(Z L Z 9L Z i Z � E1Z �Z I Z U�Z 8[ 8 1 L T 8l 2iT VIE T i Z�11 T T I �T EBF rL �9 9 Ihis I I£ ZIVIII(�I(i11111111111' 111i111l11111111111111 ►IIIIIII IIIIII1 III ((I Illllllllll�llll (II►I IIIIIIIII►�LWtllli�lllllllll�l 11 LllLWL�IuWlillllllill llilll IIII(NII