Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
10220 SW GREENBURG ROAD STE 201-4
LEGEND f DETAIL REFERENCE / SHEET REFERENCE 1 - j eDOOR NUMBER HARDWARE NUMBER M =001 PR r-- � •) I t].1CCT MANUAL I , -10EVT" REFERENCE ,osi -- __` aouna GLASS REL I TE FAFX,n . NEK/PARTIT]ON IL i-' -IrFVCfnOW\ V .-...1 - --- _ -- - - EXISTING 24' X 48' FLRSCT, FIXTURE EXISTING 24 X 49' \ r _ I« FLRSCT. FIXTURE RELOCATED J RECESSED IWCONDESCEWT \� LIGHT FIXTURE_ SWITCH 'u ' LIGHT FIXTURE V TELEPHONE TL V SIGNAL OUTLET-SEE NOTES I 1'121 + i E OR DUPLEX ELECTRICAL OUTLET SPECIAL EQU1P'MEWT OUTLET SEE NOTES --�I - FLOOR MONUMENT NEW ' 11�/'! f -- - -- - --- -- / !✓�ZZ�.NI' WITH SERVICEI SERVICESHOWN ,JUNCTION BOX THEI.MOS-TAT KMIfC3 FAC[ -(� IN 1 q PERFORATED RETURN AIR GRILL O ,� i ® EMERGENCY LIGHT ♦ LER HEAD 7 SPRINK.—� .arF SPRINKLER HEAD RELOCATED N I d �`MN "�W - ♦ SPRINKLER HEAD ADDED pfV^rel z t�Y, ;', J _� SWITCH FAN NOTOR a EXHAUST FAN I I _ SMOKE DETECTOR ALARM - SPECIAL EQUIPMENT @ NOTES - v raN ROBERT' A. BECKER SPACE PLANNING & INTERIOR DESIGN BEAYLrRTON. ORBQON 97006 (609) 642-1082 PAX (503) 628-8039 } � � {�2?-rte h v✓ �: �?.��'?.�1 PROJTCf A0: -- C1 ••F' V^✓'�''\(a %i,�/>�,li �'�N� �L�)C 4 I �!���i7 blim rril t r. pal ......................................................... ,��`r'' � ��- I ►-�I'`�6% �,..� Ef = ! ;, w ........... ... ..... . ... HCAL&00 �O CAD n : Lh................................ DAN: V CHX. aAn: �J Job Address: This conceptual spade plan and R=Yl>S101Lb: ��� , ^f�j schematic furniture lay-out Is � 10220 cw ibl� Rend By: - Date: for planning purpoeoe uly, not 1 05 for cow0xuotion. AU areae and Lincoln II North, - 51.tite 201 propeeed tenant improvements are apprelinau and subject to `�r', � t ;, ...,� ,,•. :, j'-:. 1 of 3 r..iAvna per vart8aation of tenant approval.alb 11 dwona and MW or 1 ,I ,:r.,..�..,..'nr•;•re,* ti:ilJ•'.,t ..,i.......w, .--�,v4_Nva,�.,p r*rt.:�.�,... •'• ,..- �-.�.�•v.RJV'lM'h1A'NR+'NMA'1'M�'" '('":..1..a<,.:...7NN:�•iP'hN!'xFMF:'W'4f,:b�.r rMwr,n.r. .nnarurwu. .xiebe:•.'.�I.w.NWy.,p...., If this notice appears clearer than the �/��/�� ocenu t, the doclnent is or nt: lit u•. duminal quay. I�Ijl � l � l �l � l � l Ijl ! I � I I � I �III I � I�I� I�I�I�I I' I�I�I � III � I�I �t I� I � I� I I� I � I I I � I � ! jl� l �l� l I I�I� Ijl � l �l �l ill 11111111 I I �I �I� Ill�ijl I I � I �I� III � I � I�I I I� I � I� I� I � I�� I� I �I�III� �� I� INCH ( MADE IN Ci11NA41 1 cm 2 3 4 1 1 1 1 1I IT 11 14 15 11 li 11 11 I 4 it I1 !1 zi 31 Illl�lllllllll�lllllllll�llllllllljlll!IIIIIjIIIIIIIIIjIIIIIIIII�IIIIIIIIIjIIIIIIIIII!Illlllll�llllllllljlllllllll�lllllll!Ijlllll!Ill�lllllllll�llllllllljllllllllljlllllllll�llllllllljlll!II!IIjIIIIIIIII�IIIIIIIII�I{IIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIIIIIII�IIIII'If11AC 'AMz GENERAL NOTES SYMBOLS LEGEND - TENAW, PERMIT DATE 1 . All clear dimensions are to be exact within 1/8" + along full height 1 %�R R OTT & ASSOC. wM and full width of walls. Contractor shall not adjust any dimension W marked "clear" or "clr" without written instruction from the architect. Z Building Standard Detail New Special outlet. See note at lnr.ation and tent I /M furm. Contractor shall adhere to all codes, rules and regulations governing r� construction, building access, and the use of facilities as set by 4 StoryBuilding � local building department agency and the building owners. - � New comnunications outlet for CRT mounted at building scan. ^ dard height. PAINT ` 3. All standard construction shall conform to the standard details for - Room or Space Number �^ 1 tenant improvements except a, explicitly superceded by specific MATCH EXISTING ` `1 details approved by McCAKTEiz BOCZKAJ. 1- - 3 Story Building fr�Ily� TelePhonelComnunications Floor Outlets 4. Location of all partitions and doors shall be approved by M`C_WTER 1 - -- -�-. Arrow indicates direction of face'ef nrunument) �--� 5oCZ KP.J. as marked in the field prior to construction. Contractor - - Room or Space Number shall notify M`CAitTE R 5oCZ9.V of any discrepancies or conflicts in n location of new construction. � > New building standard monument cored into flour CARPET pPET x-11\ 2� interior Elevation Number U 5. It shall be the responsibility of the contractor herein - either g. EXISTING apparent or obvious - prior to start of work on that item or bear the Sheet Number �j Existing outlet to remain responsibility of correcting such work as directed by the architect. Q ir. All blocking s to be fire treated. 4- - Detail Reference Existing monument to be removed and capped flush with top ut -_ _ Z Y LLJ 5 --Sheet Number slab. BASE LLJ �41►6 > New special outlet. See note at location and tenant E/M t,!r MATCH EXISTING U GENERAL FINISHES L �* �_ -- Section Designation � A Sheet Number New building standard monument cored into floor to be capped 1. All veritcal surfaces to be painted U.U.N., stipple texture, eggshell C/ above finished floor. ---- --- - --------- sheen. Contractor shall provide architect with a minimum of two 8x10 PLASTIC LAMINATE brushouts of each color and finish for architect's approval at least t New Casework/Millwork Built In. two weeks pr or to site application. Wall tests will be required one ;........- I See elevations and details sheet No. 12. week prior to final approval. Architect reserves the right to adjust any color once the wall test has been made. Description and date set forth in "issues and revisions" All partitions, columns and exterior walls to receive building stan- number: Denotes revision or addendum designation. dard base2r/r tall. Straight base at carpet, cove base at the flooring, U.O.N. Ic Lighting Leyencl ..�( 3. All doors to receive building standard finish throughout, U.O.N. Existing unless otherwise noted WALL COVERING v�,J 4. All glazing and glazing sections shall receive building standard Door and frame assembly. See door schedule. finishes, U.O.N. ..1�I,T New building standard 2x4 flourescent light fixture and lens. �. All HVAC fixtures, trim and accessories shall be painted to match ceiling, U.O.N. � Gypsum board ceiling or soffit. See details. FLOOR COVERING�_� New building standard 1x4 fluorescent light fixture and lens. 1 AlI millwork and casework shall receive finishes as sper.ified by M`CAMIK bocZKAJ. See millwork detail No. 12, TENANT 5TANtaARP$ Existing construction to remain building standard 2x2 fluorescent light fixture arid lens. � t^� New bui9 7. All areas, except as specifically noted, shall receive carpet. Con- tractor shall coordinate undercutting of doors with thicknes-, of Existing fluorescent light fixture to remain. carpet. Doors shall clear floor finish by 1/8" maximum. 1 Existing partition to be removed 9 9 _ I ! New tenant standard partition - floor to ceiling. See CASEWC)RK building standard detail. No. 1/10 Relocated existing fluorescent 1.., :c fixture. CEILING NOTES Q New tenant standard acoustical partition - floor to ceiling, r Existing fluorescent light fixture to be removed or relocated. M 1 . All new or relocated light fixtures and HVAC grilles to be located on See building standard detail. No. 3/10 - -_ r.eilinq grid U.O.N. Contractor shall notify OWNER of any ' conflicts with the suspended grid system, HVAC, or sprinkler fixtures Buildinq standard with- special lens `J prior to installation. ���������� New tenant special acoustical partition - floor to structure = � GENERAL NOTES O See buil6ing standard detail. No. 2/10 - T Nor USED• Z New recessed building standard incandescent downlight. �: • • • New building standard corridor wall - slab to slab. See 3. Where lights and switches are not noted with a lower case letter building standard detail. No. :,/11 switch designation, the switches are to be connected to only the lights within that specific room. t :---} New building standard par ial height glazed partition. See 1 New recessed building standard incandescent wall washer. ( 1 4. NOT U7ED• F- } details. No. 1/4 1- w 71 V New building alternatefull height glazed partition. See ( Existing downlight fixture to remain, N All switches, thermostats and any other wall mounted control devices 00. l +- . No. 214 W detail are to be mounted at +48" above the unfinished floor, U.O.N. V Relocated existing downlight fixture. 6. All exit signs are to be building standard, installed at the center of nil-rz� New custom wall. See detail. the ceiling tile shown, U.O.N. y \ Ex;sting downlight fixture to be removed. LL T I.1.J`.J O V ' 7. Unless otherwise noted, all incandescent lights to be on dimmers. New partial bright standard partition. See detail. > V Dimmer controls shall be Lutron Nova series with no exposed heat �\ Wall mounted exit sign, building standard. See plans for p O location. Arrows as indicated on plans. sinks. z New building standard. 1-hour rated wall. ( ) c R. Where switches are shown adjacent to each other, they shall be ganged and covered with a single plate. O Ceiling mounted exit sign, building standard. Arrows as indicated on plans. 9. See mechanical and electrical drawing for information regarding lighting, circuiting, and HVAC ducting layout. Electrical Wall Outlets New building standard light switch. Lower cas,� letter Z 10. Downlrghts and wall washers located at center of tiles unless other- 0 3 denotes light, to be switched. wise noted. New building standard duplex outlet mounted vertically at �j� �} 12" to C.L. New building standard 2-gang light ht switch to be wired to 4 - fixtures in compliance with Title 24 requirements Lower E LE C/TELE NOTES New building standard duplex outlet mounted horizontally at -�e� case letter denotes light to be switched. 4" to C.L. F= a O a Dimmer switch. Lower case letter denotes lights to be 1. All switch locations, thermostats and any other wall mounted control New fourplex outlet mounted at building standard height. - switched. 111III devices are to be field approved by OWNER before instal- - lation. See sheet for locations. L-___* Undercounter fluorescent lightstrrp cont, in ,pace with _ +,_..,,...,.-.fie....•. ,-...�..,�--..�...,.....,....,.....,.......,..,....,.,...,•.,�. M-,-r-•-T• . �. All standard electrical and 1• 1,-phone wall outlets are to be mounted f.xistinq duplex or fourplex to remain switch at fixture. E _._ vertically centered at 12" abu,e finished floor, or at g' horizontally as noted. ! Existing duplex or fourplex to he removed, cap off behind ----' Fluorescent light strip cont. in space. 3. All electrical devices (switches/plugs) shall be the same color as the cover plate. �G face of finish, ��. Surface mounted 1x4 fluorescent light fixture. 4. Unless otherwise doted, dinner controls shall be Lutron Nova seriesC with no exposed heat sinks. -9 pecial outlet, See note at location and T M/E form. S. Unless otherwise noted, all electrical and telephone floor monuments ra are to be building standard finish. v, Clock outle`.. See planelevation (s)and/or elevatios) for location '-' O abovo finish floor. [V 6. A minimum of 3" clear must be maintained for any floor monument adja- cWASHINGTON ent to a wall unless otherwise noted. I C rr) J Junction box. See note at location. Cl v 7. Contractor shall verify and provide correct outlets for special elec- Flf?E DISTRICT N0. 1 �' ° N APPROVAL ,DATE trical and communications equipment as noted on tenant E/M form. I FIDE PHONE BUREAU V C > a) N Plug-mold. See note at location. w- R. Provide correct amperage for all equipment noted on tenant E/M form. 4, HONE 649.8577 M Electrical Flour Outlets EXAMINED ZS O C 9. Where monuments are shown next to ea:h other, they shall be located as C10 yr -L7 close together as practical. Arrow indicates direction of face of monument) DOOR SCHEDULE. r M c 10. For outlets indicated at special mounting heights, mounting height is A� I_ � r ,IA�I_LYIAPPROVED � w � � to be measured from unfinished floor, typical outlets at special •rj New building standard duplex monument cored into floor. .r. .gam RED YP1,_11_ TUN; REQ IJIRED C) to heights shall be centered at dimension shown and mounted vertically. DOOR NAM HARDWARE W O 11. Electrical contractor shall verify and coordinate conduit runs, New building standard fourplex monument cored into floor. NO.: SIZE MATERIAL FIN18N rP W U J .J W O (� = 1 Flti.�R TO COVER FRAMING OMFLEIED ,�/ Cp circuiting, and wiring as required to provide complete electrical T Z �>_ > O = Q to 0 Z Y 2. UPON BUILDING C n'"P E;IO N �+ C00 installation. As-built records of circuiting and wiring shall be t m prepared at the project completion. ��i� Existing duplex or fourplex to remain. Verify direction of I W _ U W fZ W J LLI X = I o f a Y N = lW Y a W Q 3.6 HARDWARE SCHEDULE: ' r , 17. See mechanical and electrical drawings for further notes and infor- '' �' a = X J I ' V � ' 0 _ ' Q N I ¢ W A. Furnish the following hardware indicated on the Door Schedule, P1 ANS E XAf,11N F-- R `•(/ nation. Special outlet. See note at location and T L/M form. WIDTN NEIONT TNIt. -t m J W LL IL V Y N = 1- ' C7 U. Section 08950, or as required to complete the facility: A 3-0 8_4!; 13/4 T A O1 L1 - - IC1 I - S1 - - G1 - 20 ENTRY MANUFACTURER'S NUMBER MANUFACTURER'S NUMBER �.� Existing capped electrical or telephone outlet. - - -- -} - - - �- SYMBOL ♦QUANTITY NAME AND SIZE -_ FINISH MANUFACTURER SYMBOL QU,4NTITY NAME AND SIZE _ - _ FINISH MANUFACTURER B 6-0 8-41, 13/ _ T B Bz 1L 62 -� C2 - 52 - - G1 M1 20 ENTRY - Existing monument to be removed and capped off tlush with C 3-0 8-41a 13/ 4 ! T A B1 L3 - - - - S1 - - IMT. Butts and Hinges: Flush Bolts: top of slab. �--�'- - -- - * - -- B1 ?. pr Butts RDF'BB179 4 x 4 US4 Stanley D 3-0 8-414. 13/ 1 T A 81 L44 - - - S1 - - - - iNT. B2 4 pr Butts RDFBB179 4 x 4 US4 Stanley Tele hone/Communications Wall Outlets E 6- 8- r 13/ T B B2 L6 ' _ { - - - - _ _ FB2 1 set Auto. flush _�- - -Q S2 - M3 DUMMY Locks and Latches: bolts 599 US4 Ives F 3-0 8'4s, 13/4 T A B1 L5 - - - S1 - - - MZ DUMMY L1 1 ea Lockset 12-14-e105 LNF US4 Sargent Closers: New building standard outlet mounted at building standard -- - _ - `- L2 N_ v'_tu,_ height [G__�� 3-0 8-41, 113/4 4 A B1 L4 - - - S1 - - - - ST.RM 1.3 1 ea Lockset 2.8-24••6GO5 BS US4 Sargent Cl. 1 ea Closer 8501 Sprayed Brass Norton --- L4 1 ea Latchset 28-24.6615 BS US4 Sargent C2 2 ea Closers 8501 Sprayed Brass Norton H 3-0 1 8-414 13/44 A B1 L3 - - - - S1 - - ST,RM L5 1 ea Durrmy trim 6U93 IiS US4 Sargent Existing outlet to remain _ - - L6 2 ea Dummy trim 6U93 BS r US4 Sargent Stops: I 6-0 8-41, 13/44 B B2 L8 _ _ _ _ 52 _ _ _ M3 �, DUM L7 1 ea Dummy trim 6094 85 US4 Sargent - L8 ? ea Dummy trim 61194 BS US4 Sargent S1 1 ea Stop 4368 US4 Ives Exi,.Ling outlet to be removed - cap,off behind fate of f;ni ,h J 3-0 B-4!., 13/4•I A 81 L1 - - - S1 - - - M2 DUM S2. 2 ea Stops 4368 US4 Ives i1: i�, G Gasket i ng: /w �.lo•l-t, „k�JN1tD TEL.EI'►auHE - 54'� � r� FL.cx�iZ .__ --t- _ _ _ - -F 1/MFA 8 41j4 G G1 1 set gasketing 5050 Head R Jamb Stanley � � Miscellaneous: S ! P5 ��H. i - �5 I. M1 1 ea Coordinator - 672 Series Door Control - - - M2 1 ea Roller titch 1259-A US4 Trirnco 10220 SW Greenburg Road i M3 2 ea Roller litches 1259-A US4 Trimco Lincoln II North, Suite 201 SHVE NUtiViLR 20 3 ,, nIIlMgrrM�K. CMRESPONi)n If this notice :Ippe:u•s clearer than the �/,, tlocumeut, tile document ocen t is of marginal27/97 quality. I� I! I � I� I�I �III I11 ! 1111I 1 Il11!jlll�l�l I I�I�I�III �I�I ! I � i�l�lll �l�l I I �I �I�IIl�ijl I I� I�I�lil �l � l�i I l�i� lll� l�l�l I � I �I� III� I� Ij 1 INCH MAGE IN (MINA tIIIIIIIIIIIi►illlulllllllnllfllllllllliliillnllllnllinllnn Iiillnuinllluninnllnlllinluii!Inlllni!nlilnnl!II!IIIIIIIIIiIIIIIIIIIIIIIIIIIIIIIIIIIIII11Illllllllfllll!IIIIIIIIII IIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1111 SU 1ULMERICH & ASSOC:IATES -- SCHULMERICH & ASS00ATES00 _ 00 -PeCK o�F►« oFFI�E_ O� ICE r 11-8uON - / --- ry �10 / - - W W"• OFF�c'�. Z o CNF` INCE oFFIGE j' W v J © V C OC cr-LF- PECK Qj2 C3 - - - - -- - — ■ oil IL■ - - !✓G�h-rI C2 Ff FIGS I M Z�•Y>I 'LGiC'�}- r - - - v to --- - E• E _ wcx?-a: VEF44Fes{ r,7tT --7 -� .0 �TM _ ' ' I lo z O ELEVATOR LOBBY ELEVATOR LOBBY U J CL J I•— ?' N - -J — J r u=I J 7 uj � w _ o � --- O w a � � Nz me = f-- 00 INN 0C) M z go so or U U IN C 10 or _ro O C fY t\ U Q� O go■ ■ ) C m ■ ■ ■ ■ N C: ° � Uro > 04- o OD LL `^ W cn CL x v rr, go C x Q U V 10220 SW Greenburg Road 2ND FLOOR PLAN Lincoln II North, Suite 201 _ 2ND FLOOR PLAN 3of3 • If this nc►lice a,,hears Clearer than the. Z/27/y7 document, thmm e document is of al•ginal quality. ' I�I�I � I �I i l lll� l �l� l �l�l I I(I(I(I�I(I�I I' I(I(I(I�I�i(I�i I( I(I(I( I(I(I' I I( I �!illl �l(III(I(I�I �i (I(I I i � l�l(I�I �I(I I I(I (I( I� I({(I { i( I(I(ill(I� I(I I Ijl(I�I(I(I� I I � I �I(I� IIi� f INCH MADE IN CHINA 2 4 tll�i�Il�ulililiiilllunlillilinilinilnn!ulllullin�Ilnn InIIInllnillnn►nnlnnlllnllni!nnlnn nulnlinnlnn'linllnuinlllllll�nnluulu�Ilnlllnnlnlllnlllnn nnlnn nnillnllnllnnlnnllnllunlnn!unlnnllnlllnlinnlnlillulnnllnllln'll ............. ADDRESS: i kit)WIh..' A)00% �Q ,ie a0i i i i i I i i I i:'vecords\microflm\targets\building.doc t AP W. t :a �l a r t CERTIFICATE OF � w '07Y OF TIGARD OCCUPANCY COMMUNITY DEVELOPMENT DEPARTMENT PERMIT #. . . . . , . e BLIP'93--02tW 13128 8W Hall Blvd.Tigard,Oregon 07223.8109 (503)030.4171 DATE ISSUED: 08/29/94 1 S 135AS--01002 S I T1-. ADDRESS. . . : 102120 SW GREENBURG RD #S. cul l a SUBDIVISIUN. . . . LUNING:R--12 LaLOCI'.. . . . . . . . . . . LOT. . . . . . . . . . . . . :6 CLASS OF WORK. .-ALT TWE OF USE. . •. :COM 1 0cC1..1v'(?IUC,Y GRP. :Be- OC"CUPIANC;Y LOAD:30 Tr.NANI NAME. . . ICHRYSLER GREDTT Remzwks: Minor inL-erio r^e'ale�dF: 1 ing Owner: _._ _..,..._. ........_.......__....._._..._ ... ....... _ _. ... ......_._._....._.._. MELVIN MARK 1 QJ%.:c'171 fall ORF E NBURG RD #150 PORTLAND OR 97223 (")hone #: 4521 -5900 Con t;raut or m 'i_VTN NORK CONSTRUCT ION 10. 20 SW GREENSURG RD I SUITE #.150 I TIGARD OR 97e23 j Phone #t 45c•-`59010 f Fteg #. . : 54721 1 1 Occupancy of the artaoaN ►'w, ferenc: d building is hereby given, and certifies � the compli.mrnce with the 9tatW Of Dregon Specialty Codes for the group, � S orcr_Ipancy,, and r_tSe Under which the r•,ePerenred pz!r_m.tt watr i %sued. i 1 i J 1)1NG � _'PECTOR BU.1 C•; 1C.'IAL POST IN C11W)-r I C;UOUS PLACE- l I i i i LL LNSPECTION NOTICE City of Tigard Building Department 13125 SW Ball Blued. Tigard, Oregon 97223 Inspection Line (Rec-O-Phone): 639-4175 Busineas Phone: 639-4171 ° Inspection: y, Footing _'____'----- -- 11bg. Underelab r Mech. Rough-in ' ' Appr/Sdwlk Pound. Plbg. Top out Cn3Line FINAL; f Fost/Beam Struct. Sen. Sewer Framing -Bldg. Post/Beam Mech. Rain Drain Insulatic;: -Plumb Plbg. Undorfloor Water Line l� GYP. fid. -Koch. ! Date Royuested: f{ Address:_)<j AM __PM Permit is Builder: THE FOLLOWING W..RECTIONS ARE REQUIRED: ------------ ,i 1 Inslsectors �iAPPRO1/ED DISAPPROvED APPROVED SUBJECT TO ADM ____Call For Reinap• 08/25/94 07:49 '$°503 452 5602 LINCOLN CENTER +++ CITY OF TIGARD 2002 � A' L CITY GLASS TEL No . 1--503-684-0687 Aug 24 ,94 9 :35 No . 004 P .9 4 h6m:' iiorlhuestWo-lr*strIts, Inc, at 1(286)285-3693 ie-17-93 11:91 aN To: 13,1-503-689-8687 eel of eel �flDEfl 1 : 117558 CUSTOMER BY : 19/26/93 SHIP ON DATE: 18/2693 PAGE : 1 S 11? S 0 ALL CITY GLASS COMPANY H L 11530 S.W. TIEDEMAM ROAD I D TIGARD, OR 97223 r T T 0 PHONE: 583-6ZB-8639 FAX: 593689868? 0 16/19/33 10:11 RM DATE ORDER SLSMM F/O N0, SHIP UIR PPD F.O.B. REGION TAKEN BY COMTACI TERAS 1819/93 117558 43 14263 NUI TIGARD PHRTLM JAI FAX 249i250B USF OPT ORD ITEM DESCRIPTION MARK 10 NUMBER U"SF I/SF HUM- CUSTOM LRMIMRTED: 5,8" MIRROPAHE CAT It .838 ■SAFETY SHIELD* M/U: li9GYMP AMM .838 li8CL AMM ,838 3/16CL AMM REFL, TO 11 0001 M 1 5;8GYMP L1A Grey hlrropanc AMM LQ 29.89 28,88 SU SIZE: 47 S/8 X 59 5i0 IN ESTIMATED TOTAL SQFT= 20,80 f WGT= 169.89 SPECIAL INSTRUCTIONS: SHIPPING INSTRUCTIONS: i rN i ! ... 4' ^•.rte. T _ NI SPEC1'ION NOTICE !! city of Tigard Bui.ldinq Depart=P-nt 13125 SW Ball Blvd. Tigard, orogon 97223 IneFection Line (Rec-o-Phone): 639-4175 Business Phone: 639-4171 Inspection:.- % k '� ------- --- Footing Plbg. Underslab Mech. Rough-in Appr/Sdwlk r Foun(l. Plbg. Top Out Gas Line ?INAL: d Post/Beam Struct. San. Sewer. Framing -Bldg. _ Post/Ream Hoch. Rain Drain Insulation -Plumb. Plbg. Underfloor water Line Gyp. Bd. -Hoch. _ ! Date Requested: K 3- 9�' Timaz _ AN PN Address:%c?�_ Permit /+t 7 J Builder I i THE FOLLOWING CORRECTIONS ARE REQUIRED: e' Inspectors / SQL. Y--- ----- Date-- " APPROVED DISAPPROVED APPROVED SUBJECT TO ABOVE Call For Reinap. I { I Y .. . .tea:•, 1':I. i • Y- , f C:T 1 Y OF T I C:xARI) - RE:C E'I PT C1F" PAYMENT RE CF I IAT NO. 0 93- 24493P CHECK AMVIUNT : 109. 73 NAME: a MErt_11.TN MARK CONSTRUCTION CASH AMOUNT a 01. @0 • ADDRESS s .111 SW COLUMBIA, SUITE 1380 PAYMENT DATE. z 10/07/93 SUBDIVISION PORTLAND, OR 9 7x011-- � 4 i PURPOSE OF PAYMENT AMOUNT PAID PURPOSF: OF PAYMF-'N'T AMI':1(.)N'T PAID 104. '50 ST. T}U I l-I) Pi-,,R _. .. _.. .._._ 5. Fl.3 � or o 7 i 4 w. i.HRYSL ER 1 I.trt;?20 'c'M OREt."NBURG, SUITE. 201 J C)TAL. AMOUNT PAID 1014. 73 k p m F a'• d..e ,.. J S l,t y k. 1 I CITY OF TIGARD COMMUNITY DEVELOPMENT DEPARTMENT 13126 SW Hell Blvd.Tigard,Oregon 97223.8199 (603)639-4171 :-:jE:_i_:,., •.. , . , .,..'i1::�`l SwF : LL :`_ l Ri' -1 JI'::.P. RATE : o MEZZ?:i`v i2ki UUI REL)-.._..._,._ .. .._.:1i�C,). . . . `.y4'.i ,.., ___. .iI i f i; (.. I fi _31='f''{__.�r �"•hil.al'. UEUI'I"S. lbt` 4—f4N)U OR yg ! MORK 4yfat`ira�'-P ' SW QRfr:ENSURG #g 'P15;2—S'900 I i , , . .. W ;" . . : 64781 REQU71 MET) INSf'' a pertik is issues sifh,ect to the rVoCations contained in the F arrririg ;hard Municiol Cud#, "tate of Ore, cpe.l,aity Lades ar: all other T,r1 a .l l a1 2 uri tri s appliCable :aws: All 40rk wili be done in a-cordance with Uy;j Bcar,d Insp approved plans. iris pertit will expire if work is not started S,csp Ceiirig Insrj Within 'AN dos Cf 155uat?N, r ;f WV4 it; 11S)DeCt i U71 Iran ISO days, (:ei:1� i f'C)t^ xa'1;f @C,} j „r� .. (,:,;t�-•�+j']r i r. 1.. i 1, CjrrV r r3iuswEi,unne. PLNCK/RLCT # �� . ( 9HGARD • oj� � �r ^ PERMIT N COMMUI'ITY I)r;�'IM;1.OI'MP;N"r'I)P:r'AIL"I'Mt?NT T��``B°f� u (503)o"I-I DATE ISSUED ----___-- _ 771iFA0 z��el-le 4l0 Zalfe�ry 0 .-- -- MAP/L,01 JOB ADDRESS: � � TAX MAP LOT SUB: _ - - - J� �_�_. LAND USf:�//19r F. - OWN e �'I j� F, j VALUATION r��'' ��"� .-.....— ---f �y� ,h2a4� SPEC IAL NOTES t:AML: wa X04,6, REISSUE OF: ADDRESS:�� 2�' 7 4f1 � / &� AST REISSUE: Zo• /�.�'1PLN FLOOD PLAIN/ PHONE: _ ''�"� SENSITIVE LAND: CONTRACTORG APPROVALS REQUIRED NAME: _ _ PLANNING: ADDRESS: ENGINEERIOG: _ FIRE DEPT: PHONE: ------ ---- --_ — — OTHER: A)0',1- 7.( r CONTR. BOARD #: EXP DATE: ITEMS RE 110 IRED .,UBCOI;TRACTORS:, PLUMB: _ -_ LIST/SUBCONTRACTORS: MECH: _ — BUS TAX: ARCH ice_ CALCULATIONS: ,NAME: - _ TRUSS DETAILS: _ ' ADDRESS: — OTHER: D PRONE: �"' n 2 I i PROPOSED SLOG . USE COMMENTS: lZ - - �� -- -- —r --. J / A AN( IGNAIURE Rece i vod B Y=-�`_ ,_---- _---i- Date Received: _-- I l r PERMIT k ACCT # DESCRIPTION AMOUNT AMOUNT PD. BAL. DUE 10-432 00 Building Permit Fees 10-431 00 Olumbing Permit Fees . 10-431 01 Mechanical Permit Fees 10-230 01 State Building Tax (5q) Building Plumbing Mechanical ------ • 10 -433 00 Plans Check Fee Building _ Plumbing Mechanical —_ 10-230 06 Fire I 30-202 00 Sewer Connection 30--444 00 Sewer Inspection 25-448-02 Commercial TIF Fees 25-448-04 Industrial TIF Fees 25-448-06 Institutional TIF Fees i 2.5-448-03 Office TIF Fees 25-448-01 Residential Traffic fees 25-148-05 Mass Transit TIF Fees 52-449 00 Parks System Dev Charge (PDC) 31-450 00 S�orm Drainage Syst Dev Chrg (S SDC) - —--- ----- 24-445-01 Water Quality (fee in lieu of) 24-445-02 Water Quantity (Fee in lieu of) i TOTAL __ � '• `J i nm/3587P.W{'i 1 Is R i ILL • C 11 V PF T 1 Gr4RD RECEIPT OF' PAYMENT RE'CE I PI NO. ;y3 c 4402,? CHECK AMOUNT a 67. 93 NAME a BECKE.R, ROBERT CASH AMOUNT 0. 00 � ADDRESS a PAYMENT DATE: o''a/Q►9/93 SURD I V I t,3I ON ' PURPOGE✓ OF PAYMENT AMOUNT PAID PURPOSE OF PAYMENT AMOUNT FSA I D FLAN CHECK FE y 67. 93 i CHRYSLER CREDIT CORD-` iV 2r*''.@ SW GRE'ENBURG i TO)Al_ AMOUNT PAID —i 67. 93 i +1 j c 1 I ' ... :t F' { i CITYOF TIFARD lOctober 31, 1988 OREGON i f f f Alan Hotchkiss Trammell Crow company • 10300 SW Greenburg Road Tigard, OR 97223 a Project: Lincoln Center Two North Suites 201 and 501 7 - Dear Alan: a Plans for these projects have been reviewed for conformity with applicable { codes and are approved. You may get the building permits at your convenience. If you have any questions, or if we may be of assistance, contact us at any t time. Sincerely, M lamt Ji.m/Jaqua Plans Examiner of/7784D i i + 13125 SW Hall Blvd.,P.G.Box 23397,Tigard,Oregon 97223 (503)639-4171 — ---------- ------ afflopwri Y ► � 3 � ► t1 TUALATIN VALLEY FIRE & RESCUE AND BEAVERTON :IRE DEPARTMENT • 4755 S.W. Griffith Drive • P.O. Box 4755 • Beaverton, OR 97076 • (503) 526-2469 FAX 526-2538 i s c October 19, 1993 i 1 4 Robert Becker '° 9660 S.W. Eagle Ct . .Beaverton, Oregon 97005 Re: Chrysler Credit Corporation Two Lincoln North 10220 S.W. Greenburg Rd., Suite 201 5989B-328-004 i Dear Mr. Becker: This is a Fire and Life Safety Plan Review and is based on the 19S editions of the Unifoz,71 F.ire Code (UFC) and those sect-..,ns of. the Uniform Building Code (UBC) and Uniform Mechanical Code (UMC) specifically referencing the fire department, and other lc'cal ordinances and regulations. Plans are conditionally approved subject. to Tigard t ' Building Department requirements and uhe following i tems: I . The tenant space number must be p prominently �;a displayed on the street front where it is readily visible to drivers and officers of responding fire apparatus and other emergency vehicles. UFC Sec. 10 .208 lr 2 . Not less than one (1) approved fire �, ,• extinguisher(s) with a rating of not less than shall be provided for each (**) square foot of floor area or fraction thereof. The travel distance to an extinguisher from any portion of J the building, shall not exceed 75 feet. UFC Sec. _��' 10 .303 i r�r ot 5/ r it d��TT "Working"Smoke Detectors Save Lives ? k� TV"PIM ;✓fa6$f{".t4�eR�Y1G'Ja aM>an a c;, �� , i .ru.. '�C'!�.3✓ t � Tyr yt/ k 4{, s Robert Becker October 19, 1993 Page 2 (*) 2A10B:C - Light and Ordinary Hazard 4.A10B:C - Extra Hazard (**) 3, 000 - .Light Hazard i 1,500 - Ordinary Hazard { 1, 000 - Extra Hazard r Note: Where flammable or combustible liquids are used, "B" ratings of extinguishers may need to be higher and trevel distances shorter. See requirements in National Fire Protection Association Standard 10-1 . I � 3 . Plans referred to and examined by this office contain no provisions for the alteration or installation of automatic sprinkler system. Not less than three sets of plans for the installation shall be submitted to this office for approval prior to installation. UBC 302 (b) ApFroval of submitted plans is not z.n approval of omissions or oversights by this office or of non- compliance with any applicable regulat-:Ons of local government . If I can be of an further assistance to you, lease •� Y Y p feel free to contact me at 522460 � 9 . I 9 i Sincerely, Bradley �. Wanamaker Deputy Fire Marshal BNW:kw h cc: City of Tigard Building Department Ti y.liti 1'�I PROJECT: revisions to existing tenant offices at LINCOLN CANTER; Two Lincoln North 10220 S.W. Greenburg Rd. Portland, OR 97223 MANAGEMENT: MELVIN MARK BROKERAGE COMPANY 1.0220 S.W. Greenburg Rd. , Suite 150 Portland, OR 97223 attn: Brad Knodell, Asset Manager (503) 452-5900 i FAX: (503) 452-5602 I TENANT: CHRYSLER CREDIT CORPORATION 10220 S.W. Greenburg Rd. , Suite 201. Portland, OR 97223 attn: R. B. "Rich" Leavitt, Branch Manager (503) 244-8999 FAX: (503) DESIGNER: ROBERT A. BECKER SPACE PLANNING & INTERIOR DESIGN 9660 S.W. Eagle Ct. Beaverton, OR 97005 attn: Robert Becker (503) 646-1862 FAX: (503) 626-8039 DATE: 7 September, 1993 ISSUED FOR PERMITS AND CONSTRUCTION r x r. a � T Y b S! "1 k � Y 1 1 AIL— t *� PR.OJECT MANUAL for revisions to existinq tenant offices of: �'• CHRYSLER CREDIT CORPORATION k ' Two Lincoln North, Lincoln Center 1.0220 S.W. Greenburg Rd. , Suite 201 Portland, OR 9722.3 , A s .j.. i � J1 7 s• 'A 0 1 1: 3 S TABLE OF CONTENT r _ PAGE LOCATION OF THE WORK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 WORK UNDER THIS CONTRACT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 • WORK PERFORMED UNDER SEPARATE CONTRACTS. . . . . . . . . . . . . . . . . 2 J' • SPECIFICATIONS 1 . GENERAL. . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 — 3 2 . SUBMIT?'ALS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 . DEMOLITION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 — 7 4 . STANDARD STEEL FRAMES. . . . . . . . . . . . . . • . . . . . . • . . . . . . . . 7 5 . DOORS. . . . . . . . . . . . . . . . . . . . . . . . . . . r • . . . • • • • r • . . . . . . . . 7 6 . DOOR FINISH HARDWARE. . . . . . . . . . . . . . . • . . . . . . . • . . . . . . • 7 7 . RELITES (GLAZING) . . . . . . . . . . . . . . . . . . • • . • . • . • . . . . . . . . 6 8 . GYPSUM DRYWALL. . . . . . . . . . . . . . . . . . . r . . • . . • . . . • . • . . . . . 8 r 9 . ACOUSTICAL CEILING TILES. . . . . . . . . . . . . 8 n r 10 . CARPETING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . • • • • . . • . . 9 i .A 11 . PAINTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . • . . . . 9 12 . FIRE PROTECTION. . . . . . . . . • . . . . . . . . . . . . . • . . . . . . . . . . . . 9 13 . HVAC. . • • • • . • • • • • . . . • • • • • • ► • • • • • • • . • • • • • • • • • • • • • • . . 10 14 . ELECTRICAL. . . . . . . . . . • • • • • • • • • • • . • • • • • • r . • • • • • . . . . . 10 l� 15 . PLUMBING. . . • • • • • . . . • • • • • • • • • s • a • • • • • • • r • • • • • • • • • • . 10 i 16 . LIFE SAFETY SYSTEM. . . . . . . . . . . . • • • • • • • • • . • • • • r • • • . . 11 17. SERVICE CONFLICTS. . . . . . . . . . . . ,Y • 4I, TABLE CF CONTENTS cont. 0 r DRAWINGS SHEET 1. CASHIER'S WINDOW SECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 . (NOT USED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . • . . . . . . . . . . . 2 • ;f 3. FINISH SCHEDULE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 i 4 . GENERAL NOTES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 ' i l 5. GENERAL NOTES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 6 . FLOOR COVERING PLAN. • • • • • • • • • • • • „ • • • • 6 i1 x 4 • 1 i , 7 11 j { END RAB/14 . 6tim ; r` �y 1 J' t � •�� ""� ,. . r�rM1;YM1:nMSwK�°{S'K'ceat(�iW'dOk'f.'d'.?i+(:�'art;�xa(a:#:rre ftN«,r+wKrn,e - •._ .... �� i I. •�. dt rr y t �•' �fi a �n?,x f Ali � w s i�'a• F u'(9� h a 7,, ��i i 1 qti:7,a ��� �'4# aF4+. Fit .ir: —Xv ft 0 i• , Y 7 Sept. , 199:3 page 1 S 1 � i The following changes in the tenant leasehold at 1.0220 S.W. f Greenburg Rd. , Suite 201 , Two Lincoln North, LINCOLN CENTER, Portland, Oregon, are proposed. These Contract Documents have been reviewed and approved by Tenant and Management for application for required permits. The CONTRACT DOCUMENTS for this project are comprised of one (1) blueline, 18"x 24" print: FLOOR PLAN, Site Plan & Elevations, dated 26 July, 1993 , and a PROJECT MANUAL, cover dated 7 September, 1993 , that includes the following two (2) components: 1 . SPECIFICATIONS, dated 7 September, 1993 , generated by Robert Becker Interior Design, 2 . 8i"x 11" SHEETS (DRAWINGS) , dated 26 July, 1993, repeating information developed by GHAFARI �! Architects - Engineers for. Chrysler Financial, as generated by FISHER DESIGN, dated June 18 , 1993 , and as complied by Robert Becker. The SPECIFICATIONS and SHEETS specifically reference exist-, ing tenant improvements , details and materials, that are to „1 be duplicated or matched for this project except as specif- ically modified herein. LOCATION OF THE WORK 1 . The proposed tenant revisions are to become part of the general tenant leasehold located within approximately 3 ,000 usable square feet at the second floor of an existing building located at 10220 S.W. Greenburg Rd. , Portland, OR 97223 . Construction type: II-N, sprinklered, Occupancy: Group B, Division 2 , Building Use: administrative and management offices. ,• '+a: i' e1 7 Sept. , 1993 page 2 WORN UNDER THIS CONTRACT i 1 . All new construction and/or alteration of existing tenant office space for tenant CHRYSLER CREDIT CORPORATION as defined by these Contract Documents include, but are not limited to: (A. ) new building standard carpet, pad and base throughout; (E. ) new building standard wall paint throughout; (C. ) alteration of existing wall for the installation of security Cashier ' s Window; (D. ) alteration of existing wall. for the installation of Vision Window at Interview Room; and (E. ) install new electric release and mechanical locks on three doors. WORK PERFORMED UNDER SEPARATE CONTRACTS 1 . General furnishings and "Open Office Workstations" . These may be identified herein as "N. I.C. '' ` (not in contract) . i SPECIFICATIONS 1 . GENERAL (A. ) Work being shown and specified in these Contract Documents is intended to coordinate with existing field conditions. Dimensions take precedent over scale. U7)-ere discrepancies occur between Contract Documents and field conditions within the de- scription of work addressed herein, the Contra.c- for shall request a clarification prior to pro- ceeding with the work. 'r s 7 Sept. , 1993 page 3 (II. ) Contractor and Subcontractors shall carefully examine the existing site and Contract Documents. Errors and omissions in the plans and specifica- tions shall be called to the attention of the Designer prior to construction so that an addenda or change order, if necessary, may be issued. Failure to do so on the part of the Contractor does not relieve him of the responsi- bility to provide a correct and finished product. (C. ) All workmanship and materials shall conform to the latest adopted building code edition and to conditions and specifications of all governing authorities. (D. ) Application of materials by any Subcontractor to surfaces existing or provided under_ this contract shill imply acceptance and suitability of and to existing conditions. Such Subcontractor shall be held responsible for damage or irregularities to his product as a result of previous, conditions. (E. ) The Contractor shall obtain and pay for all permits and fees, and all additional drawings and specifications , if any, required for permits are to be supplied by General Contractor and i Subcontractors. (F. ) The Contractor shall provide and pay for dumpster (s) , and telephone as may be requested for his/her and his/her Subcontractors ' use. (G. ) No storage outside the building shall be all-owed without written authorization of the Building Management. (H. ) Management and Tenant shall not be responsible for tools or material goods stolen or damaged on site. (I . ) Upon completion, of work the Contractor shall thoroughly clean the premises so that the tenant area is acceptable for occupancy by Tenanc. (J. ) All substitution requests shall be sabmi `ted to and approved by Management, Tenant and Designer prior to implementation, i ., Ni.:. i. pry;,. '.:x t:1. •r.�.,, N+ IY WFI 4 WPM ' �I 7 Sept. , 1993 page 4 2. SUBMITTALS t A. General: Provide submittals as specified hereinafter prior to application or ordering product and material. B. Shop Drawings: (1 . ) General: Provide shop drawings in accordance with the requirements of these Contract: Documents or Manufacturer' s requests. :shop drawings shall clearly depict all materials and methods of attachment, dimensions, fabricated member detail. sections and relationships to adjoining work even though not by the same trade. (2 . ) Cashier' s Window: Provide Manufacturer' s shop drawings for new Cashier' s Window at Reception: 200 . C. Samples : (1 . ) Three each 6" x 9" or larger of paint drawdowns, in each color and sheen required to match existing on-site or new as specified by FISHER DESIGN. (See SHEET 3) (2. ) Three each samples of Roppe 4" toeless base to match existi::g on-site or new as specified by FISHER DESIGN. (See SHEET 3) , and (3 . ) Three each 9"x 9" or larger samples -1Prncn-• strating color, pattern and construction of Tenant selected carpet to match existing on-site or as new specified by FISHER DESIGN. (see SHEET 3) . 3. DEMOLITION A. General: (1 . ) Perform demolition and alterations to existing tenant improvements in accordance with these Contract Documents , conform to all applicable codes for demolition work and removal, and obtain required permits from appr.opriata governing agencies. �, _ ;,.�..�►����.-eras, ,„M,�,;�-.,. ., _. .. } i • 7 Sept. , 1993 page 5 1 9 1 (2. ) Contractor to coordinate the removal and disposal of all existing building materials scheduled to be removed with Management. (3 . ) Contractor to patch, repair or replace any surface and material not designated for demolition but is damaged during construction. Management and Contractor will determine the extent of repair required to return affectet area (s) to original condition or better. B. Scheduling: a (1 . ) Before commencing alteration or demolition submit for Management and Tenant approval a schedule showing commencement, order and completion dates for various parts of this work. (2 . ) Notify Management prior to performing work which will generate smoke or dust as existing fire alarm system is sensitive to these particles. (3 . ) Contractor to notify affected utility companies before starting work and comply with their requirements, and do not disable or disrupt building fire or life safety systems without prior written notice to Management. C. Protection: (1. ) Make explorations and probes as necessary to ascertain required protective measures betore proceeding with demolition and removal. Give particular attention to shoring and bracing requirements so as to prevent damage to existing construction. (2. ) Provide, erect and maintain lights, barriers, warning signs, and other items as may be required for proper protection of the public, occupants of building, workmen and adjacent construction. __..._.. „�'�+'^ 4� 7 Sept. , 1993 page 6 (3. ) Take necessary precautions to prevent dust and dirt from rising, and construct and maintain temporary partitions as may be required to prevent the spread of dust, odors and noise. Protect unaltered portions of existing � building by dustproof partitions and other adequate means. (4 . ) Do not close or obstruct walkway widths to exits as may comply with prevailing codes and regulations. Do not store or place materials in passageways, stairs, or other means of E' egress. Conduct operations with minimum traffic interference to general and public areas of the Building. (5. ) Be responsible for damage to existing struc- ture or contents. D. Workmanship: (1 . ) Perform demolition, removal and alteration work as shown with due care, including shoring, bracing, etc. Contractor shall take care to protect all items specifically mentioned or implied as to remain or to be relocated. I (7. . ) Execute the work in a careful and orderly manner, with the least possible disturbance to public and to occupants of building. (3 . ) Where alterations occur, or new and old work join, Contractor to cut, remove, patch, repair or refinish adjacent surfaces to the extent .required by the involved conditions to create an appearance equal to, or better than as existed prior to commencing the work. Materi- als and workmanship employed in alterations , j unless otherwise shown or specified, shall conform to that of the original work :and all alteration work shall be performed by the respective trades which normally perform the particular items of work. (4. ) Finish new and adjacent existing surfaces as '7 specified for new work. Clean existing surfaces of dirt, grease, loose paint , etc. before refinishing. I Now l J, .. .. Y� 7 Sept. , 1993 page 7 (5. ) Materials which are removed shall be consid- ered reuseable unless released by Management. Contractor is to take all necessary precau- tions in the removal of material to insure the least amount of damage. Materials which are removed shall be delivered as directe(. by the Management, or discarded as the Management may direct. 4 E. Clean-Up: (1. ) Contractor to keep area of work fr,.e of waste and debris as work progresses and naintai.n premises in neat and clean conditic.n. a 4. STANDARD STEEL FRAMES r A. General: Provide and install metai f.ramFs and k interior glazFd relite frames to match --xisting on-site, or a. specified herein. I � B. Finish: color to match existing. i 5. DOORS A. General: Existing on-site doors are to be retro-fit with specified hardware unless otherwise noted herein, or as may be required by the hardware manufacturer for compliance with waranter�s, or as may be required to assure compliance with all prevailing codes and regulations. B. Finish: to match existing on-site. C. Hardware: See GENERAL NOTES SHEET 4 and 5) D. Operation, : Doors shall be openable from the inside without the use of a key or any special knowledge or effort. 6 . DOOR FINISH HARDWARE A. General: Provide finish hardware as specified herein (See GENERAL NOTES SHEET 4 and 5) , and compliant with all current and applicable cod^s and reauL3 dons . J J J_ k t . A L , a "`M . y x. 41 7 Sept. , 1993 page 8 7 . RELITES (GLAZING) A. General: installation details and frames of new vision window are to match existing or as amended herein (See GENERAL NOTES SHEET 4 and 5) , and as may be required by governing codes and regulations. B. Sizes: as indicated. 4 8 . GYPSUM DRYWALL A. General : Provide gypsum drywall as specified herein (See SHEET 4 and 5) : all exposed gyp. bd. to be taped and sanded to match existing adjacent surface j texture per building and tenant standard, and a,.1 gyp. bd. to be minimum 5/8" thick screwect to 3J" metal studs at 16" o.c. , unless otherwise noted. B. Miscellaneous: Provide 1 }" sound attenuating batt insulation at new wall construction. C. Finish and Color: Provide painting in accordance with Color Specifications as generated by FISHER DESIGN. (See SHEET 3) . D. Backing: Provide backing plates and strongbacks on metal stud partitions wherever loads are to be supported on partitions, including as may be i required at the new Cashier' s Window. 9. ACOUSTICAL CEILING TILES A. General: Acoustical CFfling tile to conform to all prevailing codes and regulations, and be in accordance wish this Project Manual. B. Execution: Where required by prevailing codes and regulations, provide additional ceiling suspension members, accessories and bracing to structure, including where main runners are cut to make way fer other work as specified herein. Install all materials in accordance with manufacturer' s recommendations. C. Replace damaged or discolored standard I acoustical ceiling tiles with new or relocated on-site stock to match existing. Finished ceiling to be uniform in appearance. r MW r 7,. ,1 I ;` t• • t 7 Sept. , 1993 page 9 10 . CARPETING <k A. General: Carpet Subcontractor shall provide and install carpeting, and underlayment in accordance with Tenant Standards and per Color and Materials A Specifications SHEET 3 . Contractor to verify with Management the inclusion of 6" accent borders at 2 Office: 207 and Recption: 200 , similar to sketch SHEET 6 by FISHER DESIGN. B. Materials: (1 . ) Carpet: as specified. i + (2 . ) Base: as specified. 11 . PAINTING A. General : Prov'.de painting in accordance with the Color and Material Specifications SHEET 3 . B. Materials: Provide "tenant Standard" paint materials or as specified herein. In addition, Contractor to provide labeled touch-up paint, label all left over paint, and store as directed by Management. I C. Safety Precautions: Provide complete safety measures at all times for protection of persons, I materials and locations against hazards related to painting systems and materials and their use. Comply with all manufacturers recommendations in the use of their respective products. D. Paint Color Schedule: U . ) Overall wall pain" as specified SHEET 3. (2 . ) Accent wall paint (if any) : to be selected 12 . FIRE PROTECTION A. General: It is understood there will be no alterations to existing sprinkler and fire protection systems unless otherwise required for amended compliance with all current and prevailing codes and regulations. If alterations are required relative documents are to be developed and submitted by the Contractor for approval and implementation. contractor. n L r w10 rt:SYY a, } s 7 Sept. , 1993 page 10 13. HVAC: There are no anticipated alterations to the heating, ventilation, or air conditioning systems j. existing to this tenant. (no changes) i E 14 . ELECTRICAL: A. General: Basic materials and methods for all electrical systems, including but not .limited to three (3) new door strikes are to comply with Tenant' s Security Standards as noted herein (See SHEET 4 and 5) . All electrical designs for required system revisions and additions to be by Electrical Contractor who is to submit plans and specifications to Management and Tenant for review and approval prior to construction, pay all fees and obtain all permits and approvals from governing agencies necessary to complete work, and coordinate with the General Contractor those items for demolition not specifically indicated herein. (There are no changes to existing lighting. ) B. Demolition: (1 . ) Contractor to verify all existing electrical service and SlIL11 provide additional service and receptacles as required compliant to all E applicable codes and regulations. i 4 ' (2 . ) Contractor to disconnect and cap designated utilities within demolition areas and accurately record actual locations of capped utilities , if any. (3 . ) General Contractor to coordinate all systems to be located in and above the ceiling, including fire protection, smoke detectors, H,V.A.C. , electrical systems and security systems. C. Receptacles : Contractor to confirm receptacle types with Tenant and match existing outlets and cover- plates for consistency of color, unless otherwise instructed. 15 . PLUMBING: (no changes) t WW i i 1 I RE A I 7 Sept. , 1993 page 11 16 . LIFE SAFETY SYSTEM: — 1 A. General: Provide any modifications to life safety systems as may be req••ired to conform to all governing codes and if,gulations. fl 17 . SERVICE CONFLICTS A. General: Contractor shall field verify all dimensions and conditions prior to starting demolition and construction and report any discrepancies to the Designer. Where conflicts may occur between new construction, fixtures and } equipment indicated to be installed in, or adjoining the existing ceiling, structure, plumbing, fire protection, electrical, and HVAC systems, the Contractor is to bring tc the attention of Designer and Tenant before proceeding. i :1 • 1 Y a i i q END + RAB/14 . 6tim a _ .- ..m r. .:x�l!'/.Fu.g..'V.l,".50•ui7 Y+•..te'.jYW q4.i':Yr:a h .. ... ••,• n. .. - -.. .. ..«...v.wov.v�•rwwsu.w.wtrl..-._ k, d i { r. 1 f� '.r i 4 f :f 7 1 ran= m :y yppqAMR i 6uk1 tx N6 STA14DARO OTP,10.PARTITION 1 x WOOD FRANC REMOVABLE " I PART{1 10N.PROVWE Or.so. rIk!$ 0! #rNA►1Ip1. at RIYURN AT ,IAM! 1 n0•IIECt11gTY I 0 ------ - t le Gf1L r NUT ROLLED - _ �l0pti P��LppAN --' "�-�bOOT tTUOi 1 W o.C. NAIL OPENING !1000 FRAM! H Will" 1AN CATi 2 dd IA !E N �1 NO�RO! NO 1. 11T1.e: (E (� VC✓W - -- PROIHCT NO: 9NflHT SCALE: DATE: — REV - ROBERTA. BECKER • SPACE PLA".;NG do INTERIOR DESIGN fl40 ! w BAOLH C7. @elTON, oReoop: 17009 I3011 616-1I62 PAX i503> 636.10), r .. V r �d r Uri E f i t y TITLE; SHEET SCALE: _ _ DATE: _ �' REVISED: ROBERT A. BE.CKER + SPACE PLANNING & INTERIOR DESIGN 9660 3. W EAGLE CT. ■EAVERTON , OREGON 97003 17011 616-1661 PAX 13011 6161019 �yy JUN 2 5 1993 4 TOr Jeff Sholian FROtlI Liss Fisher DATEr June 18, 1993 REI Chrysler Credit Corp. Color and Materiel Specifications CARPETI Stratton Design Series III � Cut Pile 32 6z Colors Antique Cameo 36950 CARPET Reception and Rich's office only, INSET: Carpet Installer to refer to sketch for Rich's Inset pattern and dimensicne. Pattern to remain the same In reception, : except for the border is to bog 6" wide. Stratton Design Series rII Cut Pile 32. oz Colors Dockside 36920 ` PAINT: Interior half walls and connecting coluva mn only. Benjamin Moore Latex Base Color: 1119 Eggshell Finish Ilalf wall(s) wood cap only, Benjamin Moore Oil Base Enamel , semi-gloss finiah Color: 1016 Perimeter Walls kk Benjamin Moore f Latex Base Color: 1016 Z Eggshell Finish BASEe Poppe 4" toclens base Color: CT 10 Brown :'60e NarhweM VAughn SL — - Pminnd,Oregon 97210 (5031294-7090 17TLg' PRI11ECi NO: SHEET SCALE: IRATE: REVISED: - ROBERT A. BECKER 6 SPACE PLANNING & INTERIOR DESIGN 9k$0 6.M. BAOLE CT. 11AVERTON, ORgOON 97001 1!011 646 1161 FAX 41031 616.1011 i Jk f , .,... s ,<-., � �''Yn'j,�:y'�St.'k Y •.,,r... .......... - .. . .. - .-,.w.ett�diF,m+.....,.,...,, .,.. ..- _...,.. ... .....,-„ n ,....ww,.w,,..,.,...«vu„-.Enw«..._. The Following GENERAL NOTES apply to enclosed blueline print: FLOOR PLAN, dated 26 July, 1993 , revised 7 September, 1993 . OADD to existing door from Reception to Work Space, heavy duty coiiwiercial grade mortise lockset with electric door strike to be operated by Receptionist. s Contractor to verify with Tenant location of door release. Door to remain locked on the Reception side and to offer free egress from the Work Space side and to include automatic door closure. w ADD to existing door from Reception to Interview, heavy duty commercial grade mortise lockset with electric door strike to be operated by Receptionist. Contractor to verify with Tenant location of door release. Door to remain locked on the Reception side and offer free egress from the Interview side and to include automatic door closure. OADD to existing door from Interview to Work Space, Uni.can 1000-1 combination lock with combination acceL located towa-ds the Interview Room side. Door to remain locked on the Interview Room side and to offer free egress from the Work Space and to include automatic door closure. Contractor to verify location with Tenant. OPEMOVE existing portions of wall (including head condition) containing glass panels with ;” ylazi' channels and entire existing plastic laminate cu—ter. RETAIN approximately 2 ' -j " wiry wall extending south from "column" located behind existing safe. ADD new CASHIER' s WINDOW: Model VBS6642 as manufactured by Mosler, Inc . / Installations, 25257 West Eight. Mile Road, Redford. ML 48240 , attn: Mr. Ron Craddock, (800) 442-2290 , as specified on SHEET 1 , OR ALTER14ATIVE as may comply with Americans With Disabilities Act (A.D.A. ) , TITLE: PROJECT N(:: SHEET SCALE: DATE: REVISED: _ ROBERT A. DECKER • SPAC;E PL NNING & INTERIOR D 9640 3. W. EAGLE CT. BEAVERTON. OREGON 97005 (507) 646-1162 FAX (503) 626 -8039 ADD new tenant partition to conform to typical Chrysler Credit tenant standard type "A" : Floor to ceiling minimum 3" drywall on both sides of 2J " metal studs @ 16" o.c. , or as revised herein . All surfaces that. • separate Reception from the Cashier work area shall be constructed with not less than 1/8" 10 gauge hot rolled steel plate covered with one ( 1) layer of 5/8" (verify) ► gypsum wallboard for protection against medium power small arms ( . 38 super auto) . All seams of this plating shall be centered on the metal studs of the framed wall. The liner must extend to a minimum height of 84" A. F.F. Cashier side of wall to be finished with plastic laminate to match existing installation, 7O. RETAIN existing 29J"1i x 20"w x 30"d plastic laminate covered drawer cabinet: to be re-installed in similar location adjacent new wall. 8O, Existing floor mounted safe to remain : no changes. OExisting partial height (4 ' -2" ) partitions to remain: no changes . ADD 48"h x 60"w Vision Window of 3/8" (verify) transparent mirror-institutional security glass as manufactured by Viracon, 800 Park Drive, Owatonna, MN 55060 , (1-800-533-2080) , and shall be style ISG-CT V-380 (verify) , 3-ply. This material shall be installed into a rigid frame in accordance with building standard. The Vision Panel shall be a minimum of 20 square feet. and enable the employees to observe the occupants of the Interview Room. s r TITLE: PRGJECi NO: SHEET 1 _ � SCALE: DATE: _.._ REVISED: _ ROBERT A. BECKER SPACE PLANNINGI & INTERIOR DESIGN 9660 1 W. EAOLP. CT BE.AVERTON, ONEOON 9100! 1703► 646.1161 FAX (301) 616.1019 ; . IF , I IV CD L7 cl U - 1. 1 01 C m �- m _ _ � . -iT1 T-T E P. co co IF a Thr I ' I TITLE: ✓ ! i PROJECT NO: SHEET SCALE: -ld� I DATE: _ REVISED: ROBERT A. BECKER • SPACE PLANNING & INTERIOR DESIGN 9660 S W EAGLE CT BEAVERTON, OREGON 97003 ( 30JI 666.1163 PAX (303) 676-1039 r I i