Report (11) +-es hoi 0 )0-) 71/ 7 lzt 45() 70 AIL 11,111 ‘001010M. - 4016 FIRE SYSTEMS r RESIDENTIAL • COMMERCIAL • INDUSTRIAL EXCEEDING YOUR EXPECTATIONS 24/7! CTU •fids Express Are Systems 670 S. 28th Street Washougal, WA 98671 360-953-8432REG€i z �� `4.1,9 44' •toes, � RENEWAL:DEC.31,'20 Job Name : S16-111 Red Rock Center Building C Drawing : S16-111 Location : 12115 SW 70th AVE Remote Area : 1 Contract : 11-11-16 Data File : S16-111 Red Rock Center Building C 11-11-16 Area 1.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Express Fire Systems Page 1 S16-111 Red Rock Center Building C Date 11-11-16 HYDRAULIC CALCULATIONS for Project name: Red Rock Center Bldg. C Location: 12115 SW 70th AVE Drawing no: S16-111 Date: 11-11-16 Design Remote area number: 1 Remote area location: NW area on second floor Occupancy classification: LIGHT Hazard Density: .1 -Gpm/SqFt Area of application: 972-SqFt Coverage per sprinkler: 138- SqFt Type of sprinklers calculated: 5.6K No. of sprinklers calculated: 9 In-rack demand: -GPM Hose streams: 100-GPM Total water required(including hose streams): 234.671 -GPM @ 44.817- Psi Type of system: Wet Volume of dry or preaction system: -Gal Water supply information Date: 10-8-07 Location: 8624 SE 17th Ave Source: Tualatin Valley Waster District Name of contractor: Express Fire Systems Address: 670 S. 28th Street Phone number: 360-953-8432 Name of designer: Pattie Wenholz Authority having jurisdiction: City of TIGARD Notes:(Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Express Fire Systems Page 2 S16-111 Red Rock Center Building C Date 11-11-16 City Water Supply: Demand: Cl -Static Pressure : 95 D1 - Elevation : 10.321 C2- Residual Pressure: 53 D2-System Flow : 134.671 C2-Residual Flow : 2409 D2-System Pressure : 44.817 Hose( Demand ) : 100 D3-System Demand : 234.671 Safety Margin : 49.617 150 140 130 p120 R 110 E 100 : Cl S 90 — - - S 80 — - U 70 R 60 — C2 E 50 D2 40 r D$ 30 20 10 D1 . ..,.. 300 600 900 1200 1500 1800 2100 2400 2700 FLOW (NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 . Fittings Used Summary Express Fire Systems Page 3 S16-111 Red Rock Center Building C Date 11-11-16 Fitting Legend Abbrev. Name 1/2 3/6 1 1% 1% 2 2'% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcd Colt C300 Horz Butt Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a*show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H.USA 03087 Pressure / Flow Summary- STANDARD Express Fire Systems Page 4 S16-111 Red Rock Center Building C Date 11-11-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 1 23.83 5.6 7.0 na 14.82 0.1 138 7.0 2 21.83 8.37 na 3 21.83 8.4 na 4 21.83 8.78 na 5 21.83 8.83 na 6 21.83 10.02 na 7 21.83 11.47 na E 21.83 11.68 na D 21.83 14.82 na C 10.58 21.03 na B 10.58 22.11 na A 10.58 26.14 na TOR 10.58 27.27 na BOR 1.0 36.55 na UG -3.0 38.3 na BV2 -3.0 39.87 na BV1 -3.0 46.1 na CITY • 0.0 44.82 na 100.0 9 23.62 5.6 7.08 na 14.9 0.1 138 7.0 10 21.83 8.35 na 11 21.83 8.4 na 12 23.62 5.6 7.1 na 14.92 0.1 138 7.0 13 21.83 8.37 na 14 21.83 8.67 na 15 21.83 8.73 na 16 21.83 8.89 na 17 21.83 9.16 na 18 21.83 9.29 na 19 21.83 9.33 na 20 21.83 11.34 na 21 21.83 11.38 na - 22 21.83 11.52 na 23 23.83 5.6 7.02 na 14.84 0.1 138 7.0 24 21.83 8.39 na 25 23.83 5.6 7.03 na 14.85 0.1 138 7.0 26 23.62 5.6 7.12 na 14.95 0.1 138 7.0 27 23.38 5.6 7.28 na 15.11 0.1 138 7.0 28 21.83 8.44 na 29 21.83 8.52 na 30 21.83 11.2 na 31 21.83 11.27 na 32 23.38 5.6 7.28 na 15.11 0.1 138 7.0 33 21.83 8.44 na 34 21.83 8.65 na 35 23.38 5.6 7.36 na 15.19 0.1 138 7.0 The maximum velocity is 11.34 and it occurs in the pipe between nodes E and D Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A Final Calculations - Hazen-Williams - 2007 Express Fire Systems Page 5 S16-111 Red Rock Center Building C Date 11-11-16 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 1 23.83 5.60 14.82 1 T 5.762 2.000 120 7.000 to 0.0 5.762 0.866 2 21.83 14.82 1.08 0.0 7.762 0.0648 0.503 Vel = 5.19 2 21.83 -6.58 1.5 0.0 13.330 120 8.369 to 0.0 0.0 0.0 3 21.83 8.24 1.728 0.0 13.330 0.0023 0.030 Vel = 1.13 3 21.83 14.84 1.5 T 11.29 14.360 120 8.399 to 0.0 11.290 0.0 4 21.83 23.08 1.728 0.0 25.650 0.0149 0.383 Vel = 3.16 4 21.83 -6.31 1.5 0.0 6.260 120 8.782 to 0.0 0.0 0.0 5 21.83 16.77 1.728 0.0 6.260 0.0081 0.051 Vel = 2.29 5 21.83 24.82 1.5 E 5.645 21.080 120 8.833 to 0.0 5.645 0.0 6 21.83 41.59 1.728 0.0 26.725 0.0444 1.186 Vel = 5.69 6 21.83 -20.79 1.5 2T 22.58 89.500 120 10.019 to E 5.645 28.225 0.0 7 21.83 20.8 1.728 0.0 117.725 0.0123 1.450 Vel = 2.85 7 21.83 50.14 2 0.0 5.790 120 11.469 to 0.0 0.0 0.0 E 21.83 70.94 2.203 0.0 5.790 0.0364 0.211 Vel = 5.97 E 21.83 63.73 2 T 13.639 5.790 120 11.680 to E 6.819 20.458 0.0 D 21.83 _ 134.67 2.203 0.0 26.248 0.1195 3.136 Vel = 11.34 D 21.83 0.0 2 0.0 11.250 120 14.816 to 0.0 0.0 4.872 C 10.58 _ 134.67 2.203 0.0 11.250 0.1196 1.345 Vel = 11.34 C 10.58 0.0 2 E 6.819 2.210 120 21.033 to 0.0 6.819 0.0 B 10.58 134.67 2.203 0.0 9.029 0.1195 1.079 Vel = 11.34 B 10.58 0.0 2 T 13.639 20.070 120 22.112 to 0.0 13.639 0.0 A 10.58 1.34.67 2.203 0.0 33.709 0.1195 4.028 Vel = 11.34 A 10.58 0.0 2 E 6.819 2.680 120 26.140 to 0.0 6.819 0.0 TOR 10.58 134.67 2.203 0.0 9.499 0.1195 1.135 Vel = 11.34 TOR 10.58 0.0 2 B 8.183 9.580 120 27.275 to Fsp 0.0 8.183 7.149 ** Fixed Loss= 3 BOR 1 134.67 2.203 0.0 17.763 0.1195 2.122 Vel = 11.34 BOR 1 0.0 4 0.0 4.000 140 36.546 to 0.0 0.0 1.732 UG -3 _ 134.67 4.1 0.0 4.000 0.0045 0.018 Vel = 3.27 UG -3 0.0 4 3E 43.601 316.070 140 38.296 to 0.0 43.601 0.0 BV2 -3 134.67 4.1 0.0 359.671 0.0044 1.569 Vel = 3.27 BV2 -3 0.0 4 Zcd 0.0 4.000 140 39.865 to 0.0 0.0 6.217 ** Fixed Loss=6.217 BV1 -3 134.67 4.1 0.0 4.000 0.0042 0.017 Vel = 3.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Express Fire Systems Page 6 S16-111 Red Rock Center Building C Date 11-11-16 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** - Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf BV1 -3 0.0 4 0.0 4.000 140 46.099 to 0.0 0.0 -1.299 CITY 0 134.67 4.1 0.0 4.000 0.0042 0.017 Vel = 3.27 100.00 - - -_ -Qa = 100.00 CITY 234.67 44.817 K Factor= 35.05 9 23.62 5.60 14.90 1 T 5.762 1.790 120 7.084 to 0.0 5.762 0.775 10 21.83 14.9 1.08 0.0 7.552 0.0655 0.495 Vel = 5.22 10 21.83 -5.03 1.5 0.0 13.330 120 8.354 to 0.0 0.0 0.0 11 21.83 9.87 1.728 0.0 13.330 0.0032 0.042 Vel = 1.35 _ 11 21.83 14.95 1.5 T 11.29 14.360 120 8.396 to 0.0 11.290 0.0 5 21.83 24.82 1.728 0.0 25.650 0.0170 0.437 Vel = 3.40 0.0 5 - - 24.82 8.833 K Factor= 8.35 12 23.62 5.60 14.92 1 T 5.762 1.790 120 7.095 to 0.0 5.762 0.775 13 21.83 14.92 1.08 0.0 7.552 0.0657 0.496 Vel = 5.23 13 21.83 5.03 1.5 T 11.29 15.330 120 8.366 to 0.0 11.290 0.0 _ 14 21.83 19.95 1.728 0.0 26.620 0.0114 0.303 Vel = 2.73 14 21.83 16.06 2 0.0 6.270 120 8.669 to 0.0 0.0 0.0 15 21.83 36.01 2.203 0.0 6.270 0.0105 0.066 Vel = 3.0.3 15 21.83 21.41 2 0.0 6.270 120 8.735 to 0.0 0.0 0.0 16 21.83 57.42 2.203 0.0 6.270 0.0247 0.155 Vel = 4.83 16 21.83 6.31 2 0.0 8.880 120 8.890 to 0.0 0.0 0.0 17 21.83 63.73 2.203 0.0 8.880 0.0298 0.265 Vel = 5.36 17 21.83 -22.35 2 0.0 10.330 120 9.155 to 0.0 0.0 0.0 18 21.83 41.38 2.203 0.0 10.330 0.0135 0.139 Vel = 3.48 18 21.83 -20.90 2 0.0 10.340 120 9.294 to 0.0 0.0 0.0 19 21.83 20.48 2.203 0.0 10.340 0.0037 0.038 Vel = 1.72 19 21.83 0.0 1.5 2T 22.58 145.640 120 9.332 to 0.0 22.580 0.0 20 21.83 20.48 1.728 0.0 168.220 0.0120 2.013 _ Vel = 2.80 20 21.83 0.0 2 0.0 10.330 120 11.345 to 0.0 0.0 0.0 21 21.83 20.48 2.203 0.0 10.330 0.003.7 0.038 Vel = 1.72 - 21 21.83 20.90 2 0.0 10.330 120 11.383 to 0.0 0.0 0.0 22 21.83 41.38 2.203 0.0 10.330 0.0135 0.139 Vel = 3.48 22 21.83 22.35 2 0.0 5.290 120 11.522 to 0.0 0.0 0.0 E 21.83 63.73 2.203 0.0 5.290 0.0299 0.158 Vel = 5.36 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Express Fire Systems Page 7 S16-111 Red Rock Center Building C Date 11-11-16 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 E 63.73 11.680 K Factor= 18.65 23 23.83 5.60 14.84 1 T 5.762 2.000 120 7.018 to 0.0 5.762 0.866 24 21.83 14.84 1.08 0.0 7.762 0.0651 0.505 Vel = 5.20 24 21.83 6.58 1.5 T 11.29 15.330 120 8.389 to 0.0 11.290 0.0 15 21.83 21.42 1.728 0.0 26.620 0.0130 0.346 Vel = 2.93 0.0 15 21.42 8.735 K Factor= 7.25 25 23.83 5.60 14.85 1 T 5.762 2.000 120 7.028 to 0.0 5.762 0.866 3 21.83 14.85 1.08 0.0 7.762 0.0651 0.505 Vel = 5.20 0.0 3 14.85 8.399 K Factor= 5.12 26 23.62 5.60 14.95 1 T 5.762 1.790 120 7.123 to 0.0 5.762 0.775 11 21.83 14.95 1.08 0.0 7.552 0.0659 0.498 Vel = 5.24 0.0 11 14.95 8.396 K Factor= 5.16 27 23.38 5.60 15.11 1 T 5.762 1.540 120 7.280 to 0.0 5.762 0.671 28 21.83 15.11 1.08 0.0 7.302 0.0672 0.491 Vel = 5.29 28 21.83 -0.95 1.5 0.0 13.330 120 8.442 to 0.0 0.0 0.0 , 29 21.83 14.16 1.728 0.0 13.330 0.0060 0.080 Vel = 1.94 29 21.83 15.19 1.5 T 11.29 103.650 120 8.522 to 0.0 11.290 0.0 30 21.83 29.35 1.728 0.0 114.940 0.0233 2.675 Vel = 4.02 30 21.83 0.0 2 0.0 10.330 120 11.197 to 0.0 0.0 0.0 31 21.83 29.35 2.203 0.0 10.330 0.0071 0.073 Vel = 2.47 _ 31 21.83 20.78 2 0.0 10.330 120 11.270 to 0.0 0.0 0.0 7 21.83 50.13 2.203 0.0 10.330 0.0193 0.199 Vel = 4.22 0.0 7 50.13 11.469 K Factor= 14.80 32 23.38 5.60 15.11 1 T 5.762 1.540 120 7.280 to 0.0 5.762 0.671 33 21.83 15.11 1.08 0.0 7.302 0.0672 0.491 Vel = 5.29 33 21.83 0.95 1.5 T 11.29 15.330 120 8.442 to 0.0 11.290 0.0 34 21.83 16.06 1.728 0.0 26.620 0.0076 0.203 Vel = 2.20 34 21.83 0.0 2 0.0 10.330 120 8.645 to 0.0 0.0 0.0 14 21.83 16.06 2.203 0.0 10.330 0.0023 0.024 Vel = 1.35 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Express Fire Systems Page 8 S16-111 Red Rock Center Building C Date 11-11-16 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftng's Pe ******* Notes ****** - Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 14 16.06 8.669 K Factor= 5.45 35 23.38 5.60 15.19 1 T 5.762 1.540 120 7.355 to 0.0 5.762 0.671 29 21.83 15.19 1.08 0.0 7.302 0.0679 0.496 Vel = 5.32 0.0 29 15.19 8.522 K Factor= 5.20 10 21.83 5.03 1.5 0.0 13.330 120 8.354 to 0.0 0.0 0.0 13 21.83 5.03 1.728 0.0 13.330 0.0009 0.012 Vel = 0.69 0.0 13 5.03 8.366 K Factor= 1.74 2 21.83 6.58 1.5 0.0 13.330 120 8.369 to 0.0 0.0 0.0 24 21.83 6.58 1.728 0.0 13.330 0.0015 0.020 Vel = 0.90 0.0 24 _ 6.58 - - 8.389 K Factor= 2.27 4 21.83 6.31 1.5 E 5.645 62.620 120 8.782 to T 11.29 16.935 0.0 16 21.83 6.31 1.728 0.0 79.555 0.0014 0.108 Vel = 0.86 0.0 16 6.31 8.890 K Factor= 2.12 • 6 21.83 20.79 1.5 2E 11.29 79.170 120 10.019 to T 11.29 22.580 0.0 31 21.83 20.79 1.728 0.0 101.750 0.0123 1.251 Vel = 2.84 • 0.0 31 20.79 _ 11.270 K Factor= 6.19 28 21.83 0.95 1.5 0.0 13.330 120 8.442 to 0.0 0.0 0.0 33 21.83 0.95 1.728 0.0 13.330 0 0.0 Vel = 0.13 0.0 33 0.95 8.442 K Factor= 0.33 17 21.83 22.36 1.5 2T 22.58 145.640 120 9.155 to 0.0 22.580 0.0 22 21.83 22.36 1.728 0.0 168.220 0.0141 2.367 Vel = 3.06 0.0 22 22.36 _ 11.522 K Factor= 6.59 18 21.83 20.89 1.5 2T 22.58 145.640 120 9.294 to 0.0 22.580 0.0 21 21.83 20.89 1.728 0.0 168.220 0.0124 2.089 Vel = 2.86 0.0 21 20.89 11.383 K Factor= 6.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 Sheet 1 -A of 2 _ 9600 Klingerman Street P.O.Box 3365 South El Monte,CA 91733*USA j i` t .47'. ;g0:/) Phone:626.444.0541*Fax:626.444.3887 2016 - www.afcon.org e-mail:info@afcon.org i b' Sway Bracing Calculations per 2010 NFPA 13 Project/Contractor Information Seismic Brace Attachments Project: Red Rock Center#C Stucture Attachment Adapter: Project Address: 12115 SW 70th Ave -----ZGOGt7 #n/a Listed load rating: n/a Project City/St: Tigard,OR 97223 Structure Attachment Fitting: Contractor: Express Fire Systems,Inc. «%lwgyC),E? #076 Universal Locking Attachment End Contractor Address:670 SE 28th Street Listed load rating: 2,765lbload rating1,955 lb Adj. per 9.3.5.1 0.3: Contractor City/St: Washougal,WA 98671 Brace Pipe Adaptor: Brace Pipe Information .-_= 1�60zz) #n/a Listed load rating: n/a Adj.load rating per 9.3.5.10.3: n/a Lenght of Brace: 7 ft 6 in Sway Brace Fitting: Diameter of Brace: 1 in 2F@CO #035 Sway Brace(Model K) Type of Brace: Schedule 40 Listed load rating: 2,765 lb Adj.load rating per 9.3.5.10.3: 1,955 lb Angle of Brace: 45°to 59° Seismic Brace Assembly Detail Least Radius of Gyration: 0.42 L/R Value: 300 o^nP t or Eriz oto Uon E Maximum Horizontal Load: 582 lb l FASTENER PER NF PA 13 110 4110„. AFCON 0]6 Fastener Information STRUCTURAL SUPPERiING MEMBER I.NFPA 13 Fastener ❑ Listed Adapter Fasteners: / BRACE PIPE Structural Supporting Member: Wood a5-59 BEE. Orientation of connecting surface: "E" ,4111 AEEN oBs- Fastener Type: Thru Bolts-Wood Fastener Diamter: 5/8 in Brace identification no. Calculated To: NFPA Fastener Length(under head): 3-1/2 in (to be used on plans) A Maximum Load: 400 lb I. Lateral Brace ❑ Brace Longitudinal g' ❑ 4-Way Brace ' Sprinkler System Load Calculation [Fpw=CpWp(default is 0.5Cp)] Ss .95 Cp 0.5 Diameter Type Length(ft) Total(ft) Weight per ft Cp Total Weight • 2 in Dynaflow 25 ft 25.0 ft 3.69 0.5 46.13 ❑ 1-1/2 in Dynaflow 188 ft 188.0 ft 2.63 0.5 247.22 ❑ 1 in Dynathread 12 ft 12.0 ft 1.68 0.5 10.08 ❑ ,�-. .i ,.. ,.. . , 6, , , . A l' ❑ .. Total weight 303.43 Brace Connection Fpw x 1.15 348.94 d UZyO 20 4 Filename: C:1Program Files(x8f + @ ed Rock Center#C.bak '110Date: 11/14/2016 / LYV0*• i:2010.1.3840 Sheet 1 -A PENEWAL:DEC.31,20 Seismic Brace Assembly Detail Connection Orientation E /// IIIA I Iln I 'I - FASTENER PER NFPA 13 / / AFCUN 076 / o //i STRUCTURAL SUPPORTING MEMBER BRACE PIPE 45-59 DEG, : ,> 4r AFCCN 035 . Brace identification no. (to be used on plans) A H Sheet 2-B of 2 9600 Klingerman Street 7:ZSg4C)4g) P.O.Box 3365 South El Monte,CA 91733'USA Phone:626.444.0541'Fax:626.444.3887 - www.afcon.org e-mail:info@afcon.org 4, Sway Bracing Calculations per 2010 NFPA 13 Project/Contractor Information Seismic Brace Attachments Project: Red Rock Center#C Stucture Attachment Adapter: IgGOGt) #n/a Project Address: 12115 SW 70th Ave Listed load rating: n/a Project City/St: Tigard,OR 97223 Structure Attachment Fitting: Contractor: Express Fire Systems, Inc. I�GO0 #076 Universal Locking Attachment End Contractor Address:670 SE 28th Street Listed load rating: 2,765 lb Adj.load rating per 9.3.5.10.3: 1,955 lb Contractor City/St: Washougal,WA 98671 Brace Pipe Adaptor: Brace Pipe Information �(Fgoo #076 Universal Locking Attachment End Listed load rating: 2,765lbAdj.load rating per 9.3.5.10.3: 1,955 lb Lenght of Brace: 7 ft 6 in Sway Brace Fitting: Diameter of Brace: 1 in � r60,0 #410 Sway Brace Clamp Type of Brace: Schedule 40 Listed load rating: 500 lb Adj.load rating per 9.3.5.10.3: 354 lb Angle of Brace: 45°to 59° Seismic Brace Assembly Detail Least Radius of Gyration: 0.42 CONNECTION ORIENTATION E L/R Value: 300 14�l FASTENER PER NFPA 13 Maximum Horizontal Load: 582 lbeik STRUES URA SUPPORTING / MESON TUB, Fastener Information MEMBER BRACE PIPE 0 BEGUN 076 ii NFPA 13 Fastener ❑ Listed Adapter Fasteners: 45-59 DEG ..... AFCON 410 Structural Supporting Member: Wood Orientation of connecting surface: E" !--- .1„,, Fastener Type: Thru Bolts-Wood o Fastener Diamter: 5/8 in Brace identification no. Calculated To: NFPA Fastener Length(under head): 3-1/2 in (to be used on plans) B Maximum Load: 400 lb ❑ Lateral Brace U Longitudinal Brace ❑ 4-Way Brace Sprinkler System Load Calculation [Fpw=CpWp(default is 0.5Cp)] Ss .95 Cp 0.5 Diameter Type Length(ft) Total(ft) Weight per ft Cp Total Weight MI ' 2 in Dynaflow 80 ft 80.0 ft 3.69 0.5 147.60 0 ❑ - ;CTU 4 ❑ so ;`bpo 4. D cr i * ti A 1 Ilk ORi:.Gti 076, ICY ,. `' Total weight 147.60 Brace Connection4 a LYV1E4 Fpw x 1.15 169.74 Filename: C:\Program Files _RENEWAL:DEC.31,20 1 Red Rock Center#C.bak Date:11/14/2016 ... __..__._.................._ ..,.,. ....sion:2010.1.3840 Sheet 2-B Seismic Brace Assembly Detail CONNECTION ORIENTATION E moi MISIIIIIIMI 1 FASTENER PER NFPA 13 STRUCTURAL -FOI 44.0 •SUPPORTINGAFCON 076 MEMBER BRACE PIPE g —AECEN 076 45-59 DEG, • APCON 410 r1 A m 7a Brace identification no. (to be used on plans) B EMMETTPHAIR CONSTRUCTION • Date: 11/15/2016 Submittal Cover Sheet Project Name: Red Rock Center Building C Description: Fire Sprinkler Submittal -, Dr- i Sub-Contractor: Express Fire Page Quantity: 37 SHOP DRAWING J SUBMITTAL REVIEW X REVIEWED 7 REVIEWED WITH CHANGES NOTED REVISE AND RESUBMIT =i REJECTED SUBMITTAL WAS REVIEWED FOR DESIGN CONFORMITY AND GENERAL CONFORMANCE TO CONTRACT DOCUMENTS. ONLY THE SUB- CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING DIMENSIONS ATJOBSITE FOR TOLERANCE,CLEARANCE,QUANTITIES, FABRICATION, PROCESSES AND TECHNIQUES OF CONSTRUCTION, COORDINATION OF HIS WORK WITH OTHER TRADES AND FULL Reviewed for General Conformance Only. COMPLIANCE WITH CONTRACT DOCUMENTS. No exceptions noted SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED FOR COMPLETENESS Margaret Wilson AND DESIGN INTENT. ERRORS OR OMISSIONS FROM THE ORIGINAL Anderson DabrowsI Architects DESIGN DOCUMENTS TO BE THE SOLE RESPONSIBILITY OF THE SUB- CONTRACTOR OR SUPPLIER TO RECTIFY IN 1 HE EVENT OF A DISPUTE POST INSTALLATION. BY KO Date: 11/15/2016 Emmett Phair Construction Lake Oswego,OR 97034 GENERAL NOTES: Page Notes Note: Submittal documents have been reviewed for completeness and design intent. Errors or omissions from the original design documents to be the sole responsibility of the sub-contractor or supplier to rectify in the event of a dispute post installation.