Loading...
Plans (91) OFFTE COPY Engineered trusses spaced @ 24" on center CITY OPGA.RD Truss Drawing REVIEWS FOR CODE COMPLIANCE C. 00 Approved: Ii/ ILi � ,< OTC: j j it `" Permit#: L" E- me ol - , ox-q ) E- Address: 869 0 BCii -cIowe.t S---f 0 Oz.w O' Suite#: ili c:CC 5= By: ` / Date: LI- - )C CO '' SnapN Rack Series 100 Rail ol SnapN Rack Flashing w/ "L" Foot • _4_ CS6K-280M Module •/*°.° Asphalt Roofing ti°` Plywood Shiethin g Mario Peralta ® , 'Y 8690 SW Bellflower St Tigard, Or 97223 Phone 503-913-9568 5.04 kW PV ARRAY o 0 0 o 0 0 REQUIRES: 0 0 0 0 0 0 1 x Fronius 5.0-1 Inverter p Q O 0 O O 18 x CS6K-280M modules >42' 1 x 25Amp 2 Pole breaker O O O O 0 O 5/8" x 8' Ground Rod BLKBRN G5 5/8" Ground Rod Clamp O O O O 0 O SNAP N RACK O O O 2 box of 6 x 122" series 100 rail (15-09813) V . 6 x rail splices (242-04014) 481 30 x mid clamps 1.31-1.77" (242-02051) 12 x adjustable end clamps 1.49-2.00" (242-02066) 12 rail end cap (232-01023) 24" 40 x silver L foot,Black Galvanized Flashing (242-92050) 3 x ground lug assembly (242-02101) CS6K-280M Module SnapN Rack flashing & L foot SnapN Rack Series 100 Rail MECHANICAL NOTES: 000........ 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NATIONAL CODE REQUIREMENTS AND MANUFACTURERS MANUALS FOR INSTALLING A PV SYSTEM. 2. ROOF MEMBER STRUCTURE IS MANUFACTURED TRUSSES. 3. ROOF IS COMPOSITION SHINGLES ON 28°TILT. 4. MODULES MOUNTED TO SNAP N RACK ALUMINUM RACKING SYSTEM. DPI SOLARSYSTEM WEIGHT:3 PSP 5. DISTANCE BETWEEN PENETRATIONS NOT TO EXCEED 48 INCHES. 6. RAIL OVERHANG FROM PENETRATION NOT TO EXCEED 20 INCHES. 7. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS WHEN PREPARING ROOF FOR ANCHOR POINT LOCATIONS.BUILDING STRUCTURE INTEGRITY IS THE RESPONSIBILITY OF THE INSTALLER. 8 ADJUSTMENTS MAY BE NEEDED DUE TO EXISTING ROOF LAYOUT. RACKING PLAN SYSTEM SITE INFORMATION CONTRACTOR NFORMATION 1 DRAWING INFORMATION SHE.NO'. Mario Peralta COMPANYDRAWING NUMBER: DATE: 7 7�T DYNAMIC MIC P POW ER INNO NATION 12/16/2016 8690 SW Bellflower St. LICENSE NUMBER:185494 DRAWN BY:OIK REVISION:I E- 100 18 MODULES X CS6K-280M= 5.04 kW STC DC Tigard, Or 97223 CHECKED BY: PURCHASE ORDER: Pne: 503-913-9568 1GK 12" Minimum from peak to array 5"from roof surface to A top of panel BUILDING NEW SOLAR PANEL HEIGHT Mario Peralta 27' 8690 Bellflower St Tigard, Or 97223 Phone 503-913-9568 Bureau of Development Services Program Guide — Solar Water Heating and Solar Electric Generators Installed on One or Two Family Dwellings Page 14 of 15 April 3 201 _ , F ,.;A ,. , . V..,,,;„. _� 1 t. �. ,N8 SECTION A-A COLLECTOR PANEL ALTERNATE I �. CONTINUOUS SUPPORT MIN.2 X 4 JOIST RAIL AND CONNECTION OR TRUSS CHORD4..........b61:__, ANGLE BY RAIL @ 2'MAX.ON CENTER - MANUFACTURER ,.;, • 4 PROVIDE CONNECTION TO ROOF AT •'- 4'4Y'MAX.ON CENTER AND AT EACH END OF RAIL `'• t8‘Iti*‘,., MIN.5/16"LAG SCREW.EMBEDDED 2"MIN. CENTER ON ROOF FRAMING. SEAL AT ROOF PENETRATION N''''.%.%)66,ir %,.,,,,/ SECTION A-ACOLLECTOF ' ALTERNATE44iPANEL CONTINUOUS SUPPORT MIN.2 X 4 JOIST OR TRUSS RAIL AND CONNECTION CHORD 0 2'MAX.ON CENTER S ANGLE BY RAIL PROVIDE CONNECTION TO ROOF AT �. MANUFACTURER 4`-0`MAX.ON CENTER AND AT EACH END OF RAIL SEAL AT ROOF PENETRATION _ >, 4 X 4 BLOCKING BETWEEN JOI �'ww 7410. A34 FRAMING ANGLE EACH SIDE.EACH END 4 ,1„.....--apri, MIN.5/16'LAG SCREW.EMBEDDED r MIN. EQ 1 SECTION A-A COLLECTOR PANEL ALTERNATE 3 CONTINUOUS SUPPORT MIN.2 X 4 JOIST OR TRUSS RAIL AND CONNECTION :::::: jj F � liPvP4 ' oilop 11 fx DIA., OR APPROVED EQUIVALENT FLASHING AS REQUIRED TO SEAL ROOF !N MIN.(2)5116'LAG SCREWS EMBEDDED 2'MIN. CENTER ON ROOF FRAMING.LOCATE POST @ CO MAX.ON CENTER.AND AT EACH END OF RAIL 4; ztr CanadianSolar i 33 • CS6K-2751 2801285 M Canadian Solar's modules use the latest innovative *Black frame cell technology,increasing module power output and product can be system reliability,ensured by 15 years of experience provided upon in module manufacturing,well-engineered module request. design,stringent BOM quality testing,an automated manufacturing process and 100%EL testing. =-- KEY FEATURES 4. Excellent module efficiency of i 25 linear power output warranty Up to 17.41 % years 7 Cell efficiency of up to 20.0% _ �Q product warranty on materials Years and workmanship High High PTC rating of up to 90.7% PTC MANAGEMENT SYSTEM CERTIFICATES* ISO 9001:2008/Quality management system ISO 14001:2004/Standards for environmental management system '4+1kOutstanding low irradiance - OHSAS 18001:2007/International standards for occupational health&safety performance:96.5% IP67 junction box for long- PRODUCT CERTIFICATES* IEC 61215/IEC 61730:VDE/CE/MCS/JET/CEC AU/CQC 1p57 term weather endurance UL 1703/IEC 61215 performance:CEC listed(US) UL 1703:CSA/IEC 61701 ED2:VDE/IEC 62716:VDE/Take-e-way Heavy snow load up to 5400 Pa, UNI 9177 Reaction to x Fire:Class 1 C' wind load up to 2400 Pa h s ( ( (?"` 8�r e) .As there are different certificationirequirements In different markets,please contact your local Canadian Solar sales representative for the specific certificates applicable to the products in the region in which the products are to be used. CANADIAN SOLAR INC.is committed to providing high quality solar products,solar system solutions and services to customers around the world.As a leading PV project developer and manufacturer of solar modules with over 15 GW deployed around the world since 2001,Canadian Solar Inc.(NASDAQ:CSIQ)is one of the most bankable solar companies worldwide. CANADIAN SOLAR INC. 545 Speedvale Avenue West,Guelph,Ontario Ni K 1 E6,Canada,www.canadiansolar.com,support@canadiansolar.com • ENGINEERING DRAWING(mm) CS6K-280M/i-V CURVES Rear View Frame Cross Section A-A A A i • i &14x3 j LI t l -�-'" 6 6 i 1 Mounting i s € Hole ] 1 % ail 5- S. I i . J } i 1 �1 Ii g^ i 11 3-Ma 3I i j i a i Mounting Hole 2. 21;l} li I 1 ( I `1f 9 € p :V p •E I ; i . 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 6435 i 0A I ng _Mi le 1 1 i E 1000w/rn 5°C E l i i E &10 W/m' 25°C E i • 441.- I \\-- is 600 W/m' 45°C la 952 E 400 W/m' 65°C E ELECTRICAL DATA I STC* MECHANICAL DATA CS6K 275 M 280 M 285 M Specification Data Nominal Max.Power(Pmax) 275 W 280 W 285 W Cell Type Mono-crystalline,6 inch Opt.Operating Voltage(Vmp) 31.3 V 31.5 V 31.7 V Cell Arrangement 60(6 x10) Opt.Operating Current(Imp) 8.80 A 8.89 A 8.98 A Dimensions 1650 x992 x40 mm(65.0x39.1 01.57 in) . Open Circuit Voltage(Voc) 38.3 V 38.5 V 38.6 V Weight 18.2 kg(40.1 lbs) Short Circuit Current(Isc) 9.31 A 9.43 A 9.51 A Front Cover 3.2 mm tempered glass Module Efficiency 16.80% 17.11% 17.41% Frame Material Anodized aluminium alloy Operating Temperature -40°C-+85°C J-Box IP67,3 diodes Max.System Voltage 1000V(IEC)or 1000 V(UL) Cable 4 mm2(IEC)or4 mm2&12 AWG Module Fire Performance TYPE 1(UL 1703)or 1000 V(UL),1000 mm(39.4 in) CLASS C(IEC 61730) Connector T4-1000V or PV2 series Max.Series Fuse Rating 15 A Per Pallet 26 pieces,520 kg(1146.4 Ibs) Application Classification Class A Per container(40'HQ) 728 pieces Power Tolerance 0-+5 W *Under Standard Test Conditions(STC)of irradiance of 1000 Wim',spectrum AM 1.5 and cell temperature of 25°C. ELECTRICAL DATA I NOCT* TEMPERATURE CHARACTERISTICS CS6K 275 M 280 M 285 M Specification Data Nominal Max.Power(Pmax) 199 W 202 W 206 W Temperature Coefficient(Pmax) -0.41 %/°C Opt.Operating Voltage(Vmp) 28.5 V 28.7 V 28.9 V Temperature Coefficient(Voc) -0.31%/°C Opt.Operating Current(Imp) 6.95 A 7.04 A 7.12 A Temperature Coefficient(Isc) 0.053%/°C Open Circuit Voltage(Voc) 35.1 V 35.3 V 35.4 V Nominal Operating Cell Temperature 45±2°C Short Circuit Current(Isc) 7.54 A 7.63 A 7.70 A *Under Nominal Operating Cell Temperature(NOCT),irradiance of 800 W/m', spectrum AM 1.5,ambient temperature 20°C.wind speed 1 m/s. PERFORMANCE AT LOW IRRADIANCE PARTNER SECTION Outstanding performance at low irradiance,average relative efficiency of 96.5%from an irradiance of 1000 W/m2 to 200 W/m2(AM 1.5,25°C). The specification and key features described in this datasheet may deviate slightly and are not guaranteed.Due to on-going innovation,research and product enhancement,Canadian Solar Inc reserves the right to make any adjustment to the information described herein at any time without notice.Please always obtain the most recent version of the datasheet which shall be duly incorporated into the binding contract made by the parties governing all transactions related to the purchase and sale of the products described herein. Caution:For professional use only.The installation and handling of PV modules requires professional skills and should only be performed by qualified professionals. Please read the safety and installation instructions before using the modules. - CANADIAN SOLAR INC.August 2016.All rights reserved,PV Module Product Datasheet V5.52_EN h. SnaprackTM '{, Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 Roof Mount System is engineered to optimize material use, labor resources and aesthetic appeal. This innovative system simplifies the process of installing solar modules, shortens installation times, and lowers installation costs; maximizing productivity and profits. The Series 100 Roof Mount System boasts unique, pre-assembled, stainless steel "Snap- In" hardware and watertight flash attachments. This system is installed with a single tool. No cutting or drilling means less rail waste. It is fully integrated with built-in wire management, solutions for all roof types, one-size-fits-all features, and can withstand extreme environmental conditions. Series 100 is listed to UL Standard 2703 for Grounding/Bonding, Fire Classification and Mechanical Loading. UL 2703 Certification and Compliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated 4' .. " • Rail splices bond rails together, no rail ' k`' jumpers required • No drilling of rail or reaching for other tools _ required • Class A Fire Rating for Type 1 and 2 modules System Features Include liir�� 4 * Nt .2° Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling 0 1 Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Dec....rrnc ,r.'nnr'r-L''''''I''''''irrcc :. Ilncir n ennnnrarls rem/rnnfiniratnr r: Whore to Rim enannrarlt rem/whorc-tn-hi iv SnobN ra # ,,,,,-„„,:it,„:„,,,,,,,,,;,,t Solar Mounting Solutions _Stainless Bolt with Stainless Steel Bonding Splice Standard Rail Split-Lock Washer4... Bolt with Split- 4 Insert 015-09816 Lock Washer —Bonding Adjustable .End Clamp Top Bonding Splice ANC Mid Clamp Base Bonding �-Bonding AdjustableAr -gondin Channel Nut End Clamp Bottom g Stainless AO Channel Nut '/ Stainless Hardware with Bolt with / Split-Lock Washers Split Lock Bonding Adjustable Washer /' Bonding Mid Clamp Bonding Standard End Clamp s- 242-02053 "'� Rail Splice Ground Lug 242-02067 242-04015 242-02101 12-6 AWG Copper Wire . Ground Lug Assembly , (ONE REQUIRED PER ROW OF MODULES) �-Universal End Clamp(UEC) r ,;' Wave < -UEC Pull Strap UEC Wedge L Stainless Steel Bolt with Flat Washer Universal End Clamp 242-02215 Standoff—011 Clamp Assembly Channel 7 Channel Nut Rubber. Serrated Stainless_,f , Rain Collar Steel Flange Nut Nut I i--,_ Stainless Serrated Stainless 0 Flange Nut Steel Flange Bolt _.92 Degree Stainless Mill Finish L Foot Flange Standoff Bolt ii_iAll Purpose L Foot Mill Finish L Standoff Metal Roof Base(1-Hole Mill Finish L Foot Base Assembly Base Shown) Flashing L Foot Base Metal Roof Base Standoff L Foot Base with Flashing with L Foot 242-92057 242-92050 242-02037 SERIES 100 TECHNICAL DATA • 6000 Series aluminum Materials • Stainless steel • Galvanized steel and aluminum flashing • Silver and black anodized aluminum • Mill finish on select products Material Finish • Silver or black coated hardware Note:Appearance of mill finish products may vary and change over time. Wind Loads 110-190 mph (ASCE 7-10) Snow Loads 0-120 psf Array Pitch 0- 60 degrees 877-732-2860 t www.snapnrack.com t contact@snapnrack.com • Series 100 napN. rackS Tit Rail Properties for 6063 Alloy Rail Pt/ Mounting System Mean Roof Height 0 to 30 ft Rail Properties for Downward Loads Section Properties A = 0.63 in2 S = 0.34 in3 I = 0.46 in4 [11'.Stresses N Fb = 15.2 ksi Fr, = 15.2 ksi E = 10000 ksi. x112"' I Mailow = 5.17 k-in Rail Section Valla„ = 6.38 k rilmommimmill Rail Properties for Upward Loads Section Properties A = 0.41 iii S = 0.25 in3 1 = 0.11 in4 Stresses Fb = 15.2 ksi F, = 15.2 ksi a E = 10000 ksi Manow = 3.84 k-in SnapNrack Standard Rail Vallow = 4.16 k 6063 Alloy Notes 1) Rail section properties determined from test data. 2) Rail test date performed per guidelines of chapter 17 of the 2012 IBC. 3) This report is using 6063 Alloy Rail NSSE 5022 Sunrise Boulevard Fair Oaks CA 95628(916)536-9585 Page C9 of C64 Series 100 SnapNracic Vpanel Calculations&Component and Cladding Forces P 6063 Alloy Rail PV Mounting Systems Mean Roof Height 0 to 30 ft PV Panel Calculations for 39" x 65"Panel Connections Panel Dimensions 65"Long Panels Panel Width = 39.0 in N ;- �/ Panel Length = 65.0 in / Panel Weight = 70.4 41 Panel Area = 17.6 ft2 Universal End Clamp g:.:- Wind Loading ` - ASCE 7-10 Component and Cladding Wind Speed 110 to 190 mph 4 Exposure Cat. C ` Edge Distance(a) 4 Ft - Component and Cladding Zones Loading Zone 1 Zone 2 Zone 3 1,2,&3 Max -22.96 -30,71 -30.71 68.51 - Min -7621 -128.56 -197.85 12.64 1) Roof slopes from 0° to 45° Adjustable End Clamp X-Clamp 2) Wind loading from 110 mph to 190 mph 3-s Gust. 3) Edge distance a=0.1*LDH(Least Horizontal Dimension) _— Maximum Force at Mounting Bracket Component and Cladding 1 Loading Zone I Zone 2 Zone 3 Zones 1':--- 1,2,&3 End Clamp -335 -566 -871 302f Int.Clamp -671 -1132 N/A 603 ,�:``"r 1) 4 brackets minimum per PV panel to rail connection 2) Only one corner of one PV panel may be located in zone 3 3) Zone 2 may have multiple panels located in this zone Mid Clamp I Mid Clamp 2 NSSE 5022 Sunrise Boulevard Fair Oaks CA 95628(916)536-9585 Page C10 of CM VOLTAGE DROP CALCULATIONS SYSTEM INFORMATION Labels FORMALAS USED PER NEC 2011 HANDBOOK 215.2(A)(3): Vo =2*L*R*I/1000 PV MODULE RATINGS INVERTER RATINGS Photovoltaic DC Output WIRE RUN VMP IMP R L VD %VD Module Make Canadian Solar Inverter Make FRONIUS Rated MPP Current= 18.1A_ PV ARRAY TO INVERTER(w/+35°C Adder) 236.6 8.89 1.29 75 1.72 0.73% Module Model CS6K-280M Inverter Model PRIMO 5.0-1 Rated MPP Voltage= 283.5V INVERTER TO INTERCONNECT 240 20.8 1.29 10 0.54 0.22% Max Power = 280 W Max Output Power =5000W Max System Voltage=401.8V Open Circuit Voltage=38.5V Max DC Voltage = 600V Short Circuit Current= 23.6A Max Powerpoint Voltage=31.5V Nominal AC Voltage=240V Photovoltaic AC Output Short Circuit Current = 9.43A Max AC Current = 20.8A AC Output Current = 20.8A Max Powerpoint Current= 8.89A CEC Inverter Efficency=96.0% Nominal AC Voltage = 240V UTILITY METER 120/240V SINGLE PHASE 0 WEATHER HEAD rip TRANSITIONING TO 3/4"EMT CONDUIT EXPOSED TO FREE AIR: 4-#10 PV WIRE/USE-2 (RATED FOR OUTDOOR USE) FRONIUS 1 -#6 BARE COPPER WIRE GND PRIMO 5.0-1 (2)STRINGS OF 9-CS6K-280M A WITH INTEGRATED CANADIAN SOLAR MODULES IN SERIES DC DIS//ONNECT - <- /1 ` 2 3 ` 9 o i 1 <- 2 C- 3 < 9 < 00000 \ 0040i EXISTING 200A 3/4"EMT CONDUIT w/ HOUSE PANEL 2-#10 THHN CONDUCTORS 1-#10 THHN NEUTRAL 1 -#6 COPPER WIRE GND ELECTRICAL NOTES: I.CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL AND NEC REQUIREMENTS AND MANUALS FOR INSTALLING A PV SYSTEM 2.ALL COMPONENTS MUST BE GROUNDED PER NEC REQUIREMENTS 3.EACH MODULE MUST BE GROUNDED ACCORDING TO INSTALLATION REQUIREMENTS 4.ALL EQUIPMENT SHALL BE LISTED PER NEC 5.IOAWG TYPE PV WIRE USE-2/RI-IW-2 SUPPLIED WIRE FOR ALL OUTDOOR WIRING 5.1 IOAWG TFIWN-2IN METALIC CONDUIT IS ACCEPTABLE 6.PER NEC 690.17 PROVIDE A WARNING SIGN AT ALL LOCATIONS WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION.SIGN SHALL READ "WARNING-ELECTRICAL SHOCK HAZARD-DO NOT TOUCH TERMINALS-TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN OPEN POSITION'OR EQUIVALENT 7.PER NEC705.10,PROVIDE A PERMANENT PLAQUE OR DIRECTORY SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISIS AT SERVICE ENTRANCE. 8.INTERCONNECTION METHOD SHALL COMPLY WITH NEC 690.64 DPI SOLAR 000060,O(►Om® 9.A/C DISCONNECT MAY OR MAY NOT BE REQUIRED BY THE AHI 10.WIRE SIZE ASSUMES THAT CONDUIT WILLBE RUN 114 ATTIC SPACE OR LESS THAN IS IS R LABELS (SEE SHEET) EXPOSED TO SUNLIGHT.WIRE GUAGE WILL NEED TO BE INCREASED IF RUN IN CONDUIT ON THE ROOF FOR MORE THAN 10'. SYSTEM SITE INFORMATION CONTRACTOR INFORMATION J DRAWING INFORMATION ELECTRICAL DIAGRAM Mario Peralta COMPANY NAME: DRAWING NUMBER: DATE. SHEET NO DYNAMIC POWER INNOVATION 12/23/2016 8690 SW Bellflower St. DRAWN BY: REVISION:0 E- 100 18 MODULES X CS6K-280M=5.04 kW STC DC Tigard, Oregon 97223 LICENSE NUMBER: 185494 CHECKED BYG: PURCHASE ORDER: Phone 503-913-9568 3GK PERALTA f Perfect Welding/Solar Energy/Perfect Charging Irronius SHIFTING THE LIMITS FRONIUS PRIMO /The future of residential solar is here-Introducing the new Fronius Primo. „J ` ., ..."--T �� \� • •—•—•.' N ...�mq ori ) ' 1+ : . ., , T ::::% -4 kV—1101.—E . �.— l r Ea- /PC board /SnapiNverter /Wii-Fie /SuperFlex /Smart Grid /Arc Fault Circuit r 4 ° replacement process mounting system interface Design Ready Interruption --,7,4, /With power categories ranging from 3.8 kW to 15.0 kW, the transformerless Fronius Primo is the ideal compact single-phase inverter for residential applications.The sleek design is equipped with the SnaplNverter hinge mounting system which allows for lightweight, secure and convenient installation. The Fronius Primo has several integrated features that set it apart from competitors including dual powerpoint trackers, high system voltage, a wide input voltage range, Wi-Fi* and SunSpec Modbus interface, and Fronius'online and mobile monitoring platform Fronius Solar.web. The Fronius Primo also works seamlessly with the Fronius Rapid Shutdown Box for a reliable NEC 2014 , solution**and offers a Revenue Grade Metering option completely integrated. TECHNICAL DATA FRONIUS PRIMO tA ' M %7 f , t;: t„`r.ra`rj:.stz"' V rk 1 it ,mss^ Clv �` 'F.c' ,?'s,.t: ,' ^<i t:i' ,: +:g,{ ,,,r s .s: , . . /�{,.,, .. � .�_ .§ �'�,�£^"�� : �° �"�'�.,t. "`,� `.�,< 7',<,a� 1.� �r � rEv .,� a' ra;� ._,e . _ ._>✓', . , _ P t,ra,�'', ret, Dimensions(width x height x depth) 16.9 x 24.7 x 8.1 in. 20.1 x 28.5 x 8.9 in. ,,ty ,.fzr� "" ..n... ?F < ,.<., %.BLL<,< "S 00., 3� ,�°.,. 'a*.`,,.., .r . s.e:. -,4.;' #,717 .-..,R'l _ ia .. 2.. L....r,._�.s.. Degree of protection NEMA 4X Inverter topology Transformerless � Installation g Indoor and outdoor installation Permitted humidity 0-100,%/ ?7'-i..-5:t';;:4 . t1 'a ;a Wom- � F , y " :: '''�711 cae te ,Zt to � t r t ,a� . l � tt•tt` . 'tttFttt , .,s . . a #h M 1,10«tris .. ,: iron 0. 1. _,..F'.., s .a ,sem, AC connection terminals Screw6 AWG �' �.� .7.41: ,a. . s A r ,f' 'a rP t—�r f ;'z;,,�. .r as '�".tali 6. A4171,i _ir v . .,.�� :1.� _ � UL 1741-2010,UL1998(for functions:AFCI and isolation UL 1741-2015,UL1998(for functions:AFCI,"RCMII and isolation 1 monitoring),IEEE 1547-2003,IEEE 1547.1-2003,ANSI/IEEE monitoring),IEEE 1547-2003,IEEE 1547.1-2003,ANSI/IEEE Certificates and compliance with standards C62.41,FCC Part 15 A&13,NEC Article 690,C22.2 No.107.1-01 C62.41,FCC Part 15 A 8;13,NEC Article 690-2014,C22.2 No. (September 2001),UL1699B Issue 2-2013,CSA TIL M-07 Issue 1 107.1-01(September 2001),UL1699B Issue 2-2013,CSA TIL -2013 M-07 Issue 1-2013s. ; . ,,t, i, ' -t . f 6 S' ,,:, - s i r o r ,�s c ;,:, "`s "!"t ,"°'" r.r„a # �`.' ,7. 0! t L' ,'` > ,>*`z °5, '"s 3 "� �*. ��_ w..�.._,�. r" ,..,z,3<" '� _�__< �.rr�u��..� .. _ .��:s'L��es.�...�<..w x., , .: .c y. �`.�` .._< ,c._ _.� „moi AFCI&2014 NEC Ready Yes i,:.,,,(1',,,:*;: -4j*-* a E.: sN"�' � : hr t.�ar?� r 3 �� , �t� ta` ',.its < . g `t"5- ;;' ,' s 4,4;01' `+ Mott:.� t ion t to°, .� �e_ottti. ,: __..s"ti .ar}r<;_'int zi,o: ,t P DC disconnect Yes t' , f t ,� r art ...1-- " ft '"x "7, ,';,,,. ' `'` r"`i7"�-% t:;l 'M� " `r _i7i3tr���iefla�-. .. ,�iP4.-., �,. _.. ._. . �-.����„�_,ate. _..� .�-..__<_. -_,r. �,w�<a . rr�,x: �'.�z �.��s.,-��4uk.><, `�_�„til • ,.st r' o x t,� ?' to,� ' '« t 1 s, . �tttoo.`tfir ga 'fii,.'.`. ;r t t B oo `1 A( s` � ,, r 4 STA 1 t R -11V1TI A L P IMO MOOD �° �r w � -. .sxs,x”_< #o,'Biel,.. -, ,�. i$ ,` . .. ,. .. :l.,v t= i.. ,'a. ,re ITIt i«e�' Ire, ',> kr,iA ..,s' itAz°.,"r- z-`'_. °'* Wi Fi/Etheinet/Serial _.__. Wirelessstandard 802.11 b/g/n/Fronius Solar.web,SuanSpec Modbus TCP,(SON/SunSpec Modbus RTU ii�nWlj�gg4TiS4 —� r at. � fr � C� yf ' s7 tifst ;;, Mti rke ,e USB(A socket) Datalogging and/or updating via USB Datalogger and Webserver Included 'The term Wi-Fi a)is a registered trademark of the Wi-Fi Alliance. "'Fronius Primo 10.0-15.0 kW requires an external disconnect button for code compliance. TECHNICAL DATA FRONIUS PRIMO i�PU ATA PRIMO 3.8-1 `P$1MO 501-7 PRIMO 6 0-1 PRIMO 75-1. , PRIMO . 441 Recommended PV power(kWp) 3.0-6.0 kW 4.0-7.8 kW 4.8-9.3 kW 6.1-11.7 kW 6.6-12.7 kW MMttA, ioinpiu1 +74' 3/MPPTZ 1.8Af78A 183T!18A ISA:1111A 18AI18A, `= 18Af1.8& ' Total max.DC current 36 A •M;14 1 , f o ril.2s zlIMPPraIMP021 244A44-42-4*. ----_,, :. Operating voltage range 80 V-600 V 144,40-at voit 40i1 V Nominal input voltage 410 V 420 V 420 V 420 V 420 V A4iiiii-O a ts3nelu toz= -AWVO 14-AWS MPP Voltage Range 200-480 V 240-480 V 240-480 V 250 480 V 270-480 V NumerofM'fi'f"1= ` >4 , _ _@�- -- _ D1 TPUi OATH; s .' � ,tom n< -z =` 4 , >,' _ .� f, tier 1i i$4lb01 701,1MOTb4� f Max.output power 240 V ' 3800 W 5000 W 6000 W 7600 W 8200 W e<@ -mom'` g 'iit.,, - j r= ::Sy '- 7 >i 0/ 41111111111111klax.continuous output current 240 V 15.8 A 20.8 A 25.0 A 31.7 A 34.2 A Recommended OCPD/AC breaker size 240 V 20 A 30 A 35 A 40 A 45 Aalb = r. 2718V_ 2'� SOA SIA SOA 81L1, < Max.Efficiency 96.7 96.9% 96.9% 96.9% 97.0% titCECT t nci :: • t40. ,- -,--:,----404,-,..-,,-:- °` - § -$16 --7,0;9:-.i6= „ '6-1)-1C-; -a llv 1C! Aclmissable conductor size AC AWG 14-AWG 6 Gridcanla cion - :20s/240V Frequency _ 60 Hz Total l ara7lonic dis orllon a 54-44 -- 0 Power factor(cos rP,r.r) - 11.851 incl./cap... _ - , INPUT DATA PRIM0100-1 - `PRIMO 11.44 _-4101110:12.51--- •--t-:-_ -i19110i!i i 11 0 Recommended PV power(kWp) S.0-12.0 kW 9.1 13.7 kW 10.0-15.0 kW 12.0 18.0 kW Max.usable input-Oirrent(1NPPT IJMPPT 21 33.0 A J.18.0 A -- Total max.DC current 51 A Max.arra?.-short s t tit citrrgnl 1 251nSi x).(MEPT 5/AWP3 - ,. 47.3 A 12.5 A ----,===c,,='-e,-,:---- - Operating voltage range 80 V-600 V Malc.it1pul voltage Nominal input voltage 415 V 420 V 425 V 440 V x - ,51WG �9s4s -tlio�.1rs -ves30,.#la.p.41 ((tWCj0gror °4elu9nhut felt` 11rot ti1edevtoet Admirsulale titndikior size DC ,a o 1 6 i 1:2 t40.41r1i)j,( iniis,i 9+G$tsiraa ar or A 4`8 13iihiiii41*Iii lie atc�A 4 la3 aPft+t ar aln 04 in**13=W19h gp#lousl 3apUt t nnl tier i --:.< __ MPP Voltage Range 220 480 V 240-480 V 260-480 V 320-480 V lnusgitt •77Czs(ting(we holders, 4van44+i`nr-144? f foo fusing iegi lt't t;tn M?P 2 ;, Number of MPPT 2 007PU DATA( PRIMO 1 01 >> PRIiV40:-1 .4-71:-. ,--.---,,--.,.--T----R-,=4._=-0-,., ,-2-_i*--.-:,. M 15 U=1 Max.output power 240 V 9995 W 11400 W 12500 W 15000 W 208 v ` 99iii`+t+----'77'- --- -'-.">-- -1-14-6-0i4125ili0 W -7T Q W Max.continuous output current 240 V 41.6 A 47.5 A 52.1 A 62.5 A 114 208 V 48,1,A 5 8A G�l A 68 A Recommended OCPD/AC breaker size 240 V 60 A 60 A 70 A 80 A 208 V 70 A 70 Ji- -8-1)-A - 901t Max.Efficiency 96.7% •GE4.E43icleacy 96.0 .; , -94.5 AWG 10•AWG 2 copper(solid/stranded/fine stranded)(AWG 10 copper or AWG 8 aluminium for overcurrent protective devices Admissable conductor size ACL up to 60A,from 61 to 100A minimum AWG 8 for copper or AWG 6 aluminium has to be used),AWG 6-AWG 2 copper(svlid/ stranded)MulliContactWiringable with AWG 12 Gridwls4iedian 2081290 V Frequency . - 60 Hz Total IliTi.lipnic distortion (3.414 cos rt,1:.. , Power factor _ . ( I, ) 0-I find./cap. /Perfect Welding/Solar Energy/Perfect Charging WE HAVE THREE DIVISIONS AND ONE PASSION:SHIFTING THE LIMITS OF POSSIBILITY. SU(ISPZ=C /Whether wrlding technology photovoltaics or battery charging technology-our goal is clearly del fined:to be the innovation leader.With around C us -_vss ci)aNeE- 3.300 employees worldwide,we shift the limits of what's possible-our record of over 900 granted patents is testimony to this.While others progress step by step,we innovate in leaps and bounds.lust as„eve always done.The responsible rise of our resources forms the basis of our corporate policy. FroriiuS USA.LLC • m„....t.. a..,1...ute,tl,,,,r I:s marl . w, L.r, „t.tw, •.r.°,16,z.sosss 6797 Fronius Drive Portage,IN 46368 USA • pv-support-usa@fronius.com Rev. 4.8.101.1SA - www.fronius-usa.com ts/ 8" Mtp ID : 02S 11 iDA 06500 0�� 6r° pat,e'0 HERITAGE No 2 SW Bellflower St. 52 .28' 29 Roof peak @ 27' N ' �s. Roof Slope @ 30° `" Total roof area = 1626 sf Total array = 626. 7 sf cA Roof % covered = 20 . 1 % •71- ., _ ,- L., kr) , ›- . ,^, E ,-, 07i '-c-' ------- ° P cb SOLAR '',,' 71- CD 5 ' ARRAY � o 14' a ›- < 16.5' •`D 71 . 28' DPI LAP Mario Peralta 8690 SW Bellflower St Tigard, Oregon 97223 SCALE : 1 "= 10' Phone : 503-913-9568