Loading...
Report (26) 8 BUP2005-00300 10801 SW CANTERBURY LN 9 BUP2005-00298 10813 SW CANTERBURY LN 13 BUP2005-00303 10771 SW CANTERBURY LN 14 BUP2005-00302 10779 SW CANTERBURY LN 15 BUP2005-00301 10783 SW CANTERBURY LN 20 BUP2005-00309 10711 SW CANTERBURY LN January 20, 2006 .__ . -- 21 BUP2005-00308 10719 SW CANTERBURY LN 22 BUP2005-00307 10727 SW CANTERBURY LN TY OF TIGARD JND Fire Sprinkler INC 23 BUP2005-00306 10735 SW CANTERBURY LN J DFiruton 24 BUP2005-00305 10743 SW CANTERBURY LN OREGON 12155 SW Grant Ave. Suite D 25 BUP2005-00304 10749 SW CANTERBURY LN Tigard, OR 97223 29 BUP2005-00297 10825 SW CANTERBURY LN 30 BUP2005-00309 10711 SW CANTERBURY LN •- 31 BUP2005-00281 10863 SW CANTERBURY LN 32 BUP2005-00283 10877 SW CANTERBURY LN RE: FIRE SPRINKLER SYSTEM-NFPA 13R SYSTEM REVIEW Project Information Building Permit: Varies Buildings: 8,9,13-15,20-25&29-32 Occupancy Type: RI Area: 2 Story+Basement, 7,324 Sq Ft Address: Varies Construction Type: VN- Sprinklered Tenant Name: Canterbury Crest Hazard: Ordinary Group I The plan review was performed under the State of Oregon Structural Specialty Code(OSSC) 2004 edition, Oregon Fire Code 2004 edition; and NFPA 13. The following information is required in order to complete the review. 1. Documents for deferred submittal items shall be submitted to the registered design professional in responsiblecharge char e who shall review them and forward them to the building official with a notation indicating that the deferred submittal documents have been reviewed and been found to be in general conformance to the design of the building. The deferred submittal items shall not be installed until the design and submittal documents have been approved by the building official. OSSC 106.3.4.2 2. The submitted plans are incomplete,the following list indicates what is required on plans, the ** indicates what is not shown on the plans: NFPA 13 R 6.1 6.1.7 Sprinkler plans shall indicate the following: (1)The name of owner and occupant (2)The location,including street address (3)The point of compass (4)The ceiling construction** (5)The full height cross section (6)The location of fire walls** (7)The location of partitions (8)The occupancy of each area or room (9)The location and size of concealed spaces, attics, closets,and bathrooms (10)Any small enclosures in which no sprinklers are to be installed (11)The size of the city main in the street, pressure,whether dead-end or circulating and, if dead-end, the direction and distance to the nearest circulating main, and the city 13125 SW Hall Blvd., Tigard, OR 97223(503)639-4171 TDD(503)684-2772 main test results including elevation of the test hydrant** (12)The make, manufacturer,type,heat-response element,temperature rating, and nominal orifice size of the sprinkler (13)The temperature rating and location of high-temperature sprinklers (14)The number of sprinklers on each riser,per floor** (15)The kind and location of alarm bells (16)The type of pipe and fittings (17)The type of protection for nonmetallic pipe** (18)*The nominal pipe size with lengths shown to scale (19)The location and size of riser nipples (20)The types of fittings and joints and the locations of all welds and bends (21)The types and locations of hangers, sleeves, and braces, and methods of securing sprinklers,where applicable** (22)All control valves,check valves, drain pipes, and test connections (23)The underground pipe size,length, location,weight,material,and point of connection to the city main;type of valves, meters,and valve pits; and depth at which the top of the pipe is laid below grade** (24)In the case of hydraulically designed systems,the material to be included on the hydraulic data nameplate (25)The name and address of the contractor 3. The approved plans for buildings 8,9,13-15,&29-32 are type VN 2 story w/basement buildings. Your submitted plans and sprinkler calculations do not match the approved set of plans. Please provide an item by item response. When submitting revised drawings or additional information, please attach a copy of the enclosed City of Tigard,Letter of Transmittal. The letter of transmittal assists the City of Tigard in tracking and processing the documents. Respectful) , V enzel, Senior Plans Examiner