Report (25) 17 BUP2005-00295 10731 SW CANTERBURY LN 19 BUP2005-0299 10715 SW CANTERBURY LN
r • - 18 BUP2005-00296 10723 SW CANTERBURY LN 26 BUP2005-00284 10797 SW CANTERBURY LN
;ew
((d,2 Fire Marshal's Offices
North Division- 14480 SW Jenkins Rd.,Beaverton,OR 97005• PH(503)356-4700•Fax(503)644-2214
South Division-7401 SW Washo Ct.,Ste. 101,Tualatin,OR 97062 •PH(503)612-7000•Fax(503)612-7003
Tualatin Valley
Fire & Rescue
27 BUP2005-00286 10793 SW CANTERBURY LN
Building Survey Report 28 BUP2005-00287 10789 SW CANTERBURY LN
FMZ : (to be filled out by TVF&R) Code Edition: 98OSSC
Name of Facility: Canterbury Woods 10 BUP2005-00299 10715 SW CANTERBURY LN
11 BUP2005-00291 10769 SW CANTERBURY LN
Name of Building: 2 story Townhome Buildings 10-12, 16-19, 26-28 12 BUP2005-00292 10765 SW CANTERBURY LN
Address: SA 16 BUP2005-00293 10739 SW CANTERBURY LN
Owner: Polygon Northwest Telephone No. (360) 695-7700
Architect: Leonard J. Milbrandt Telephone No. (425) 454-7130
Architect Address:
ITEM COMM DESCRIPTION
1. Occupancy Type R1 Use 4 unit condo Capacity None
2. Construction Type V-N Year Built
3. Area(Sq.Ft.) Total 6878 Largest Floor 2 Basement None
4. Stories No 2 Height 26'-10" High Rise DY ®N
5 a. Exterior Wall Construction WF-Non-rated
b. Opening Protection None
6. Interior Wall Construction GB on WF/GB on WT
7. Floor Construction Carpet-Ply-WGL-GB
8. Roof Construction Class "C" RS-Roof Felt-Ply-WT @ 24" o.c.
9. Attic Draft Stops No. Yes-3
10a. Occ. Sep.Wall Construction No. Yes-3 GB-WF-Insulation-Airspace-WF-GB
b. Opening Protection None
hi a. Fire Wall Construction No. None
b. Opening Protection None
12a. Smoke Barrier Wall Construction No. None
b. Opening Protection None
13a. Corridor Wall Construction None
b. Opening Protection None
14a. Corridor Ceiling Construction None
b. Opening Protection None
15a. Shafts No. None Type
b. Opening Protection None
A
Building Survey Report
FMZ : (to be filled out by TVF&R)
Name of Facility: Canterbury Woods
ITEM COMM. DESCRIPTION
16a. Stair Enclosure No. None Open stairway/None
b. Opening Protection None
17. Stairs No. 4
18. Ramps No. None
19. Interior Finish Class Room None Exit Enclosure Corridor
20. Exits No. 4 Total WidthNone
per 98OSSC
21. Exit Hardware Type Knob
22a. Exit Signs/Illumination None
b. Emergency Lighting None
23. Auto Sprinkler Coverage Yes-P
24. Standpipe Class/Locations None
25. Fire Alarm Type/Coverage Yes-
26. Heating,Ventilation&Air Conditioning Type Unit Heat Fuel Electric
27. Electrical Installation Romex-Circuit breaker
28. Stage/Platform None
29. Hazardous Area None
30. Other
Comments:
Alternate Materials&Methods
TVF&R Use Only
Inspected By: Date No.Attachments
Reviewed By: Date
Updated