Report (54) ic ' 1 .4 uponor fy.. ... ;°'''''''' FIRE SAFETY SYSTEMS g AQUASAFEn' FLOW TEST VERIFICATION FORM AcuaSAFE ` Flow Test Verification Form Alliance / Important:Instating contractor must submit this Member ID: f411 I Ct.,. 1 `0 i ekes completed form.Failure to do so nullifies the Company rki ��/ system warranty.E-mail or fax completed form l �{S to the Uponor Fire Safety Design Department Contact: r ri. at technicalservtcesOkrponorcotp or 952.997.1731, Phone; ,. j -Ac f '+� For questions,contact Uponor Technical Services at 888.594.7726 or technicaLservicesup+orror eom. Fax: Color of test orifice used: b4 S Job Name: 1c "re t•,C is c. Static pressure(not flowing)reading atncomiy Project Number., water supply into home or at main shutoff: Job Address: j f%Sr,r p �6 k icese907 papressure(flowing)reading at incomin.9 water City: l � supply into home or at main shutoff: ,.....5State,ZIP: l , 7-Z,.. For designs not provided by Uponor,complete the What time of day was the flow test taken? rT'"� following information. Flow test method used?,l Bucket 0 Flow Meter Designer's Name: ;,/"tP_•l.;seu. (244 C `Z._ Flow test gpm: Company: } > How many gallons of water did the design predict 1.�' - ' ` ^�^ a as required? Phone: 5� .3 Did the test meet or exceed design flovv?-11 Yes fl No Fax: Which sprinkler did you flow?Number: a. is the warning sign,perm ently attached close to the Location of head: i main shutoff valve? Yes 0 Na ii, Was this system required by code? es No Date left in service with all valves open: Test witnessed and Verified b Y: Names Signature � F2 Q o Additional Explanations and Notes F9s Uponor,inc Tel:800.321.4739 5925 148th Street West Fax:952.997.1731 Apple Valley,MN 551.24 USA Web:www.uponor-usa.com Jr ms , sof aoo „/ uponor To: Whom it May Concern From: Evan Benedict Re: River Terrace, Uponor Project#19816F Date: 11/11/16 The intermediate temperature sprinkler head shown on some plans in the mechanical room for River Terrace are not necessary. With the intermediate sprinkler head taken out of the system, the system will not be negatively affected. According to the NFPA 13-D Standard Chapter 8.3 Location of Sprinklers 8.3.8 Sprinklers shall not be required in closets in garages and exterior closets(regardless of size) located on exterior balconies, exterior breezeways/corridors, or accessed from outdoors where the closet does not have doors or unprotected penetrations directly into the dwelling unit. Plans that show the sprinkler head in the mechanical closet accessed from the garage, and without negatively impacting the system with its removal, can be omitted. Sincerely, Evan Benedict Design Technician—Fire Safety Uponor North America Uponor, Inc. Uponor Ltd. 5925 148th Street West 2000 Argentia Rd., Plaza 1, Ste. 200 Apple Valley, MN 55124 Mississauga, ON L5N 1W1 T 800.321.4739 T 888.994.7726 F 952.891.2008 F 800.638.9517 W www.uponor-usa.corn W www.uponor.ca