Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
gEINIANCHESTER .. EQUIPMENT SUBMITTAL . ECEIVED for NOV 3 2016 Rose CityFutsalCIt TIGAa BUILT INN DIVISION 10831 SW Cascade Ave. Tigard, OR 97224 Fire Detection and Alarm System submitted by GB Manchester Inc. CCB 202097 MODEL # DESCRIPTION MFG PFC-6030 FIRE ALARM CONTROL PANEL POTTER PS1270 BATTERY, 12V/7AH (FACP AND NAC) POWER SONIC RA-6500 REMOTE ANNUNCIATOR, RED POTTER PSN-106 AUX POWER SUPPLY, 10A POTTER PSA PHOTO SMOKE DET POTTER APS-DA PULL STATION, DUAL ACTION POTTER SCM-4 SINGLE INPUT MODULE POTTER DCM-4 DUAL INPUT MODULE POTTER HS24-WW HORN-STROBE, WALL, WHITE POTTER S24-WW STROBE-ONLY, WALL, WHITE POTTER HS24-177W HORN-STROBE, WALL, WHITE, 177CD POTTER STI-9708 WIRE GUARD FOR HORN-STROBE, WHITE STI 6000 NE 88th St, Vancouver, WA. 98665 Portland 503.287.1112 Vancouver 360.816.0484 Toll Free 877.816.0484 THIS PAGE INTENTIONALLY LEFT BLANK P POTFER The Symbol of Protection FIRE ALARM CONTROL PANEL Features • 30 Analog/Addressable Points in Any Combination • 3.5 Amp Power Supply • 2 NACS,Regulated,Rated at 3 Amps each • Strobe Synchronization and System Wide Sync for Potter/ AMSECO®,Gentex®,Cooper Wheelock®and System Sensor® tcc' strobes • System Wide Class A or B • 99 Software Zones • Large LCD and Keypad for Ease of Operation • Cabinet will house 8 or 18 Ah batteries.Dead Front Cabinet for Clean Look • Smoke Detector Drift Compensation and Maintenance Alerts • PFC 6030 NFPA 72 Compliant Smoke Sensitivity Test Built-In �-�-� "�<°fines • 1,000 Event History Buffer �"( �s °�°' � FRP • Optional two line DACT with UD-1000 that can report General, Zone,or Point • P-Link Communication Line for Annunciators and Accessories • E-Mail System Status,Reports and Event Information • Integrated,listed IP Communicator • Ethernet Port for Programming and Network Connectivity ® { 7 i,. NYC Fire Dept. Electrical Specs:AC Mains Battery: Certificate of Approval 3.0 Amps @ 120 VAC 50/60 H2 • 130 mA Standby S735 7165-0328:0195 6157 • 2.0 Amps @ 240 VAC 50/60 H2 • 220mAAlarm Product includes a 5 year warranty Size(W x H x D): 16"x 17"x 3 7/8" Description The PFC-6030 is a versatile thirty point analog/addressable fire alarm control panel that utilizes the Potter/Nohmi device protocol that has a complete line of initiating and control devices.The SLC is capable of 50 ohms of resistance and does not require the use of twisted or shielded wire.The thirty(30)points may be any combination of smoke sensors,heat detectors or modules. The PFC-6030 has a metal cabinet with a key lock and a dead front standard.The cabinet will house 8 Ah or 18 Ah batteries.The large viewing window allows easy viewing of the LCD and the standard LEDs.The keypad allows easy operation and navigation of the system menu. All of the outputs are power limited,are power regulated and may be programmed for Potter/AMSECO,Gentexe4,CooperWheelocke4 and System Sensor®strobe synchronization.The outputs may be configured for any combination of strobe brands and all will sync.The outputs also may be configured for door holder power,auxiliary power and constant power. The panel has auto-programming learn mode that will not affect the existing system when adding or deleting a device.The system is capable of 99 software zones,cross zoning and counting zones.The panel is fully programmed from a PC based software program that will work with Microsoft XP,Vista or Windows 7.0 operating systems. The PFC-6030 has an Ethernet connection for programming network connectivity and IP reporting communicator.The system uses a simple patch cable for connecting a PC to the panel.In addition,the system may be connected to a building network and programmed while on the network.The system has a built in e-mail function and will send system E-mail reminders.The IP communicator is listed with the Sur-Gard III IP receiver. The panel will support P-Link devices which include:the RA-6075,RA-6500 and LED-16 Annunciators,RLY 5 Relay Module,SPG-1000 Se- rial Parallel Gateway(printer card),an FCB-1000 Remote Ethernet/IP connection,DRV-50 LED driver for 50 LEDs,PSN-1000 Remote Power Supplies(10 Amp)and FIB-1000 P-Link Fiber Interface Module.In addition,the panel allows for the installation of the UD-1000 dual line telephone line digital alarm communicator transmitter(DACT).The UD-1000 is programmable for a single line or dual line and is compatible with Ademco's Contact ID or SIA DCS protocols. The complete system may be converted to Class A with a CA-6075 module.The CA-6075 provides the hardware necessary to convert the re- mote annunciators through the Potter P-Link connection protocol,the NACs and the SLC to Class A operation. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-956-1211•Tech Support:866-240-1870•Canada:888-882-1833•www.pottersignal.corn PRINTED IN USA MKT.#8830024-REV A PAGE 1 OF 3 11/13 PFC-6030 P POTTER FIRE ALARM CONTROL PANEL e The Symbol of Protection SLC Loop Accessories The control panel may be connected with up to thirty(30)addressable devices or modules in any combination.The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector—a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135°Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135°F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6"round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4"round base that is mounted to an electrical box and wired for connection of one of the above sensors AIB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC.One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local,group and all call.The sounder follows the pattern sent to the device. Modules Device Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4"square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel.Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module switches monitored power and is activated by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors. SCI Short Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. P-Link Devices Device Description RA-6075 LCD/keypad remote annunciator with a metal enclosure and key lock. RA-6500 160 Character LCD.Keypad remote annunciator with metal enclosure and key lock. LED-16 LED remote annucniator capable of displaying alarms,supervisory,and trouble status for 16 zones. PSN-1000 10 Amp Intelligent power supply. RLY-5 5 Form C Relay Card. SPG-1000 Serial/Parallel Printer Card,Optional Rack Mount. FCB-1000 Fire Communications Bridge, 1 may be added for remote IP Communicator. FIB-1000 Fiber Interface Module,used in pairs to convert P-Link over multimode fiber,optional rack mount. PAGE 2 OF 3 PRINTED IN USA MKT.#8830024-REV A 11/13 P PATTER PFC-6030 t The Symbol of Protection FIRE ALARM CONTROL PANEL SLC Circuit Diagram �,/ Ethernet or IP Receiver UD-1000 RA-6075 LCD Annunciator Digital Alarm 0._,.,s (Used on P200 and Alarm Monitoring ,t ,� Communicator PFC-6030) r-)r .y Stations ...20a0.111 4e RR-6500 : K P-Link LCD Annunciator NACs SLC 0 s`%4 CS/CHS AE-8 Selectable Candela 8 Device Ceiling Strobe or Strobe/Horn ',. Expansion Enclosure 3 Amp NAC RLY 5 CircuitsI Relay Expander S-24/HS-24 Selectable Candela xi' 4 P _' Strobe or Strobe/Horn >�p t' CA-6075 Class A Module (/}t�j f'5••3� ti/ - SLC Loop II I I Ii II AB-6 - ASB-6 AIB-6 ARB-6 Detector Base • Analog Sounder Isolator Base 441110k Analog Relay %. PSA Base RHABase Smoke Detector -,‘, PSHA �6,,: Heat Detector ,, FHA '=Smoke Detector '' Heat Detector e /Heat Detector II II I I II • .TRM-4 MOM-4 DCM-4 ' SCI . Twin Relay • A Monitored Output Dual Contact . Short Circuit r'. Module " ' Module ,`4 ' , Module -. Isolator I I I I II CIZM-4 ' SCM-4 ., MCM Conventional Single Contact Miniature Contact Initiatin Zoneoil .,i ; Modules Module , Module PS-24 CO-12/24 . P32-1T Smoke Detector Carbon Monoxide Pull Station ?-' * Detector v'1 PRINTED IN USA MKT.#8830024-REV A PAGE 3 OF 3 11/13 THIS PAGE INTENTIONALLY LEFT BLANK POWAEAP ii// // /l am ti ///!!!!!//!!!!// /a0 PS-1270 12 Volt 7.0 AH . Rechargeable Sealed Lead Acid Battery We've Gotrite ' Features *_ .. ,,5 , . ' • Absorbent Glass Mat (AGM)technology for superior performance . • Valve regulated, spill proof construction allows safe sealed Raci,ar.-air operation in any position Power/volume ratio yielding unrivaled energy density „„„DEL f',7-127,.,Fi f • Rugged impact resistant ABS case and cover (UL94-HB) "". • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 20845 X11 o Terminals (mm) Performance Specifications • Fl-Quick disconnect Nominal Voltage 12 volts(6 cells) tabs,0.187"x 0.032"- Mate with AMP.INC. Fl F2 Nominal Capacity - FASTON"187"series l-32-1 )-3.4-) 20-hr. (350mA to 10.50 volts) 7.00 AH OR -- WM 4m MI 10 hr. (650mA to 10.50 volts) 6.50 AH • F2-Quick disconnect 6.35-I 7s5-I 5-hr. 1.2Ato 10.20 volts) 6.00 AH tabs,0.250"x 0.032" ®=o.a � �� , =u.6 -Mate with AMP.INC 1-hr. (4.5A to 9.00 volts) 4.50 AH FASTON"250"series 15-min. (14A to 9.00 volts) 3.50 AH Physical Dimensions: in(mm) Approximate weight 4.80 lbs.(2.18 kg) Energy Density(20-hr.rate) 1.49 W-h/in3(90.95 W-h/I) D I Specific Energy(20-hr.rate) 17.50 W-h/Ib(38.58 W-h/kg) W internal Resistance(approx.) 23 milliohms D3 i Max Discharge Current(7 Min.) 21.0 amperes Max Short-Duration Discharge Current(10 Sec.) 70.0 amperes f- , Shelf Life(%of nominal capacity at 68°F(20°C)) T °-'1::::::"''''' T 1 Month 97% P� HT H 3 Months 91% MOD�n OSY/µF1 6 Months 83% w powr�.nic.mm ti Operating Temperature Range _L H L I Charge -4°F(-20°C)to 122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) - L:5.95(151) W:2.56(65) H:3.70(94) HT:3.86(98) Case ABS Plastic Tolerances are+/-0.04 in.(+/-1mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-12800A,12800A-C height dimensions.All data subject to change without notice. To ensure safe and efficient operation always refer to the latest edition of our Technical Manual,as published on our website. All data subject to change without notice. www.power-sonic.com /POWER�117;/NON/C. PS-1270 12 Volt 7.0 AH 100 14.0 III I I I I I I o I Chargngisnot Ambient Temperature 20°C(68°F) necessary unless O 100%of capacity 13.0 1 :_ r:::> (41°F)- 120snecessary dto hej 11.0 _ to may fail � R0.35 40°C 30°C 20°C capacity.Do not .E 10.0 0.70- - 5 40 (104°F)-(86°F) (68°F) let batteries reach € 1.4 cs I I I this state. 1 3.5 a o I 9.0 Final t) 0 2 4 6 8 10 12 14 16 18 20 Voltage 7.0 Standing Period(Months) 8.0 I I I 14 1.2 2.4 6 12 24 36 48 1 2 4 6 810 20 40 1� min _H h _I Discharge Time 20 15 \ 10 r Ambient Temperature 20°C(68'F) o 5 Final a 100 1 , 1 I I I E Voltage 2 10.5V \\ 580 R 10.2V 60 o _ 1 \ Float Charging Voltage y C 40 2.25-2.30 V/Cell O 30 9.6V \\ c7. 20 c t •E 9.0V0 1 2 3 4 10 \ \40 °C (104°F) Years 20°C (68°F) 0°C (32°F) 5 s.1V1 i 0.35 0.70 1.4 3.5 7.0 14 120 Discharge Current(A) 100 - Charging z, 80 Cycle Applications:Limit initial current to 2.1A-Charge until battery voltage m (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 R 60 Discharge Discharge Discharge volts until current drops to under 70mA.Battery is fully charged under these Depth 100% Depth 50%O Depth i 0% conditions,and charger should be disconnected or switched to"float"voltage. 0 40 d 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of m 20 2.Charge Current:0.1C I I I 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its re 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 0 200 400 600 800 1000 1200 Note:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperative that they be charged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 I national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com international sates@powersonic.com CORPORATE OFFICE• 7550 Panasonic Way• San Diego,CA 92154• USA•Tel:+1-619-661-2020 • Fax:+1619-661-3650 0211 1n1 c 2011.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. P POTTER RA-6500 The Symbol of Protection LCD ANNUNCIATOR Features • Operates with all Potter PFC-6000 series ' *moo • Industry leading 4 line by 40 Character LCD -000 * • Common buttons for navigation 000 Ct. Common LEDs for status indication C:3 • 31 annunciator per panel ©("OT1E • Maximum wire length of 6,500 feet Size(W x H x D):9 13/16"x 7 1/6"x 1 11/16" Electrical Specs ® • Standby Current 20 mA • Alarm Current 50 mA S2930 7165-0328: 0195 Product includes a 5 year warranty Description Installation The RA-6500 is a LCD remote annunciator for the PFC-6000 Series The RA-6500 is connected to the fire alarm control panel using a addressable fire control panels.The RA-6500 communicates using a four wire RS-485 connection.The connection is power limited and RS-485 connection to the main panel providing common indication supervised.Up to thirty-one(31)RA-6500 LCD annunciators can be of Alarms,Supervisory,Trouble and other system status and control connected using Class B or Class A wiring. functions. The RA-6500 features a 4x40, 160 character LCD display with LED's _ for Power,Alarm,Supervisory,Trouble,and Silenced conditions. It can be mounted on a single gang electrical box or a four squaremgolkorinnwilit electrical box.The annunciator is enclosed in a sheet metal enclosure Install in accordance with compatible installation manual. and has a Potter lock securing the keypad. Figure 1:Class B Wiring Example Figure 2:Class A Wiring Example ue inext anrvunriatnr F l+: A rder . P-LNK t `xr.nnr1icw±. • I ' I L l t+ Conaneciuxn ' �t ate Car, -AIM i� ' 1 + j Annu+•Giator r A $ .411 •a Remate e Potter Electric Signal Company, LLC • St. Louis, MO • 800-325-3936• Canada: 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#8830031-REV 1 PAGE 1 OF 1 11/11 THIS PAGE INTENTIONALLY LEFT BLANK . P POTTER PSN SERIES The Symbol of Protection POWER SUPPLY UL,cUL,CSFM Listed \ ` • PSN-64 has 6 amps regulated with 4 Outputs y• PSN-106 has 10 amps regulated with 6 Outputs • • Outputs Rated at 3 amps maximum each N.. • May be configured as up to three class"A"Style"Z"notification circuits • 3 amp,24 VDC programmable output powerMK • Supervised Battery Charger:27.3 @ lA(supports 7-55 AH batteries) • Easy to install cabinet with leveling mounts and key lock • Wiring knockouts provided on sides and top of cabinet • Two Trouble Relays(5A at 30VDC) General System Trouble(programmable for AC delay) Low AC Trouble with optional delay settings • Diagnostic LED's patent pending Status LED's for Active NAC and NAC trouble conditions Status LED's for Earth Fault(Amber),AC(Green),Battery Fault(Amber) • Trouble Memory feature captures troubles which have previously restored ®US • Synchronized notification appliance circuits Potter/AMSECO®,Wheelock®,Gentex®,System Sensor® LISTED S2930 7315-0328.0189 • Configurable output circuits(DIP switch sets options for each circuit) • 15 mA at 8-33 VDC input trigger Product includes a 5 year warranty • Reference EOL allows 2K—27K EOL value to be used • Quadrasync provides panel wide synchronization of same or multiple brands Dimenions: 16 1/8"W x 16 3/4"H x 3 1/2"D • PassThru mode allows the Outputs to match the Input Signal • Electrical Specs: Stock Ntiuber:3006436 PSN-64 Red Enclosure • 120/240 VAC 50-60 Hz input 3006437 PSN-106 Red Enclosure • 5.1 Amps @ 120 VAC or 2.5 Amps @ 240 VAC 3006446 PSN-106 Black Enclosure • Standby Current 60 mA • Alarm Current 200 mA* *no external load Description The PSN series of notification power supplies offers reliable notification Sensor®strobe devices.Each output can be configured the same sync power with unprecedented versatility.The power supplies offer either protocol or set independently. 6 or 10 amps of continuous power through 4 or 6 outputs respectively. In addition,the panel has an input PassThru mode allows the outputs Each output is rated at 3 amps and it may be used continuously without to follow the input signal and sync up the input flash.The panel will any derating. recognize the type of input being supplied and pass this through to the The power supply operates on either 120 VAC or 220 VAC power input outputs with the same pattern.This input pass through can be selected and has a regulated 24 VDC output.In addition,the panel can charge on each output independently. up to 55 AH batteries and leads the industry in housing up to 18 AH The power supply contains simple dipswitch programming and LED batteries.The cabinet is constructed out of 18 gauge cold rolled steel and indications providing the installer indications of the operation and the has a durable red powder coat finish.In addition,a key lock is provided ability to correct any faults.A Trouble Memory is provided to allow an for securing the door.Ample electrical knockouts are provided on the installer to review past troubles and make the necessary repairs.Each sides and the top,allowing the installer options for running wires and output has an LED to pin point the exact circuit where a problem may maintaining the correct separations. have occurred.Relays are provided for monitoring the general system The power supply offers an industry leading Quadrasync function that and AC failure. allows for multiple strobe circuits ofdifferent brands to be synchronized Each output and be independently configured for various applications to flash at the same time.The panel can have four different brands each and installations.Each output can be independently configured for Class connected to its own circuit and all of the strobes flash together. A or Class B operation,constant power,ANSI Temporal Code 3,Single, Each output can independently be configured to provide one of Multiple or Combo Inputs or Door Holder Power. four synchronizations or steady power. This provides unequivocal flexibility in new and retrofit installations.The panel can be configured to synchronize Potter/AMSECO®, Gentex®, Wheelock® and System Potter Electric Signal Co.,LLC•St.Louis,MO•Cust Service: 866-240-1870•Tech Support: 866-956-1211 •Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MKT.#8910013-REV C2 PAGE 1 OF 2 11/12 P POTTER PSN SERIES The Symbol of Protection POWER SUPPLY PSN-106 Wiring Diagram a a 120/240 VAC GND FAULT c,1_Jumper Position DETECT ENABLE ONIIo otiol OFF 120VAC 50Hz-60Hz __ _ J 240VAC 50Hz-60Hz Black Connect to separate White unswitched AC circuit Ground status LEDs NACI NAC2 NAC3 NAC4 NAGS NAC6 DC PWR F0-1 • O S S8 I 36leeeeeeegi leeneaeeg 00 — H N ❑ o of COMM• Iftl r11 11 to Fuse - D Be88" 2 Do 0 0 0 - III 0 o 1411 '3 Ll El o ,� -. Irl r LL U n 0 MU'S4 Factory Installed Interconnect• El AC Power o MOO' s • Low Battery O ` Gnd Fault ❑ I O .page'S6 Comm 0 ❑ Pa riO Bulk Options IoI 1 �. i ,►� ►JI►.�V�� ��' II O 0 NACI NAC2 NAC3 NAC4 NAC6 DC PWR REF INI M2 0 + + + - + + + + Enl +FOI - +POT NC COM NO NC COM NO t Battery+ —_ $atteny- pp _..al E.O.L. Common relays are Reference non-power limited. E.p.L. E.O.L. DC Power Trigger . + Battery connection(non-power limited) Note:PSN-64 and PSN-106 draw 15 mA when polarity reverses and the power Use two(2)I2V batteries connected m seriessupply is triggered.There is no current draw in Standby Mode. Engineering Specification The contractor shall supply and install the Potter PSN power supply.The assemblies.The LEDs shall have distinct flash patterns to provide further power supply shall operate on either 120 or 240 VAC input.The panel indication ofthe troubles present.The panel shall have selectable Trouble shall be capable of continuous load power without any degradation to Memory to provide the installer an indication that a past trouble existed the main supply or the distribution board.The cabinet shall be capable of on a circuit for diagnostic purposes. housing up to 18 AH batteries and the panel shall be capable of charging Each output of the power supply shall be capable of 3 amps of continuous up to 55 AH batteries in an external cabinet. power without degradation over time.The power supply shall provide for The panel shall have dip switches for simplistic configuration of the multiple circuits ofstrobe appliances.The power supply shall synchronize system and LEDs to provide visual indication to the installer ofthe status the flashes of any of the above listed strobe appliances on a per circuit of the system.The dip switches shall allow for AC power delay selection, basis.Up to four different strobe circuits may be connected and all of Class A/B operation per output,Door Holder Power options,constant the strobes shall flash in unison as required by UL 864.In addition to auxiliary power,trigger input type,ANSI Code 3 Temporal Code,Pass this Quadrasync feature, the panel shall allow any of the four above Thru(input tracking),Potter/AMSECO®sync,Gentex®Sync,System mentioned sync patterns as an input and pass this signal through and Sensor®Sync or Wheelock®sync.The LEDs shall provide indication synchronize the outputs to match the input flash pattern. of communication between the power supply and distribution circuit PRINTED IN USA MKT.#8910013-REV C2 PAGE 2 OF 2 11/12 SA PPOTTER•I%IDHIWI PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR Features • Low profile,less than 2 inches with the base • Wide selectable sensitivity range of 1.05 to 3.82%/foot • Sensor communicates sensitivity to control panel • UL listed smoke calibration and sensitivity • Optional locking tab to prevent unwanted removal • Simple and accurate address setting without mechanical switches r r • LEDs for 360°viewing a �k 414, ayr , can USM) S24776 7165-0328:0194 Product includes a 5 year warranty Description Before connecting a device to the SLC loop,take the following The Photoelectric Smoke Sensor is a listed Analog Addressable smoke precautions to prevent potential damage to SLC or device.Verify the sensor compatible with any fire alarm control panel that has the Potter/ following: Nohmi protocol.The PSA is a low profile smoke sensor with a wide 1. Power to the device is removed sensitivity range.The sensor and base(not included)are made of a 2. Field wiring is correctly installed. durable plastic in an eggshell white to blend in with the ceiling. 3. Field wiring has no open or short circuits. The PSA has a sensitivity range of 1.05 to 3.82%per foot and is UL Document discrepancies and notify appropriate personnel. and cUL listed.The PSA may be configured for drift compensation and has built in dirty detector warning as well as.The PSA and Specifications the control panel communicate over a proven and robust digital communication path and the system analyzes the level of alarm at the Item PSA particular device.The total polling speed is less than five(5)seconds, Working voltage range 22.0 to 24.0 V well under the UL requirements. Standby current 325µA The PSA has two LEDs that allow for 360°viewing.The sensor is Alarm indicator 2 LEDs compatible with any of the Potter/Nohmi bases and simply twists on. Alarm indicator current 1.2 mA D.C. The PSA is addressed using the hand held programmer or the control Alarm set point range 1.05 to 3.82%/ft /3.4 to 12.0%/m panel addressing function. Installation temperature range 32 to 120°F/ 0 to 49°C Air Velocity Ratings Operating relative humidity 0%to 93%(Non-condensing) The PSA has an Open Area of Protection air velocity rating of 0 to 300 range feeter minute. Start-uptime Max. 1 sec. P Maximum number of 127 The system has a maximum of 13 LEDs that can be turned on addresses per loop simultaneously.If the system already has 13 LEDs on,the PSA will Maximum number of lighted 13 operate even though the LED will not illuminate. indicators in alarm per zone. Color Eggshell White Setting the Address Weight(without base) 84g(2.96oz) Each addressable module,smoke sensor,heat detector and Dimensions(without base) Height: 1.33 in(34mm) combination sensor/detector must have the address set before Diameter:4.0 inches(99mm) connecting the device to the SLC loop.The address is set using the hand held device programmer or the addressing feature on the control Approvals/Listings UL,cUL,CSFM panel. Potter Electric Signal Company,LLC•St.Louis,MO•Cust Service:866-240-1870•Tech Support:866-956-1211•Canada:888-882-1833•www pottersignal.COM PRINTED IN USA MKT.#8830015-REV C PAGE 1 OF 2 06/13 PSA POTFER.IVDHIWI PHOTOELECTRIC SMOKE The Symbol of Protection SENSOR Operation The PSA is an analog addressable sensor that uses one address on the Signaling Line Circuit(SLC)of a compatible fire alarm control panel.The unit communicates with the control panel as it is polled.The LEDs flash every time the unit is polled and they will latch steady if the unit is in an active status. The PSA is a proven design being in service throughout the world.The PSA with the AB-4 or AB-6 base has a low profile of less than two(2) inches to blend into the surrounding environment.The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the entire unit can be cleaned with a simple vacuum. Sensor Sensitivity The PSA and the compatible control panel work in tandem to keep the sensitivity consistent.As the sensor is installed over time,the sensor com- pensates for the dirt in the unit until it is out of range.At that time,the panel will indicate a dirty sensor.The sensor will then have to be cleaned or replaced. Anytime the PSA is being polled,the sensitivity may be viewed or printed from the control panel. Note:As required by NFPA,do not install the sensors until all construction is complete and the work area has been thoroughly cleaned.If the sensors have been installed in a construction environment,they should be cleaned or replaced before the system is placed into service. Spacing The PSA is UL/ULC listed with a recommended maximum spacing of 30 feet.Refer to NFPA 72 for specific information regarding detector spacing,placement and special applications. Compatible Bases All bases will mount on a single gang,double gang,octagon,4"square or mud ring electrical box. Device Description \ ` AB-4 4"Standard Base AB-6 6"Standard Base IAIB 6"base with an isolator module included.The base is pre-wired with a pluggable jumper to the module. ARB 6"base with a dual relay module included.One relay is rated for 8 amps at 240 VAC/30 VDC and the second is rated for 2 amps at 240 VAC/30 VDC.The base is pre-wired with a pluggable jumper to the module. ASB 6"base with sounder module included.Sound pattern is provided from external source.The base is pre-wired with a pluggable jumper into the module. PRINTED IN USA MKT.#8830015-REV C PAGE 2 OF 2 06/13 • APS-SA/DA P POTTER Addressable Pull Station ® The Symbol of Protection Single/Dual Action Features • Single or Dual Action versions \ ` • Durable die-cast construction y • Reset key matches the fire alarm control panelsfig € LA [ RE FARM • Compatible with all PFC-6000,PFC-8000,and P Series panels k f t • Product includes a 5 year warranty �''F T Stock Numbers ULL 00"N \ `• APS-SA Addressable Pull Station,Single Action—1430810 ` �• APS-DA Addressable Pull Station,Dual Action—1430811 PULL i • a a�7TEg P a.; cc) . I LISTED 7150-0328:0201 S25236 Application Technical Specifications The APS-SA/DA is compatible with Potter's PFC-6000 series and Operating Voltage 22.0 24.0 VDC PFC-8500 addressable fire alarm control panels. It is a non-coded addressable pull station available in either a single or dual action Max SLC Standby Current 0.325mA model and installs on a single box or surface mounts using the P32-BB Max SLC Alarm Current 0.325mA or P32-DBB(deep)back box. I 32°F- 120°F(0°-49°C) Description Environmental Limitations Indoor Only The APS-SA(Single Action)is activated by simply pulling the white Dimensions 4.75"H x 3.25"W x 1.75"D "T" bar handle down. The APS-DA (Dual Action) is activated by Relative Humidity Range 0-93%(non-condensing) lifting the front cover and then pulling the white"T"bar handle down. Single gang box or Once activated,the"T"bar cannot be reset without opening the front Mounting Options cover. Opening the front cover will also activate the pull station. To Potter P32-BB/DBB reset the APS Series,use the Potter WS-93 key to unlock and open the APS-SA- 1.22 lbs. front cover. Once the cover is open,push the"T"bar back into the Shipping Weight APS-DA- 1.46 lbs. normal position and re-secure the front cover. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com 8830052-REV B • 10/14 PAGE 1 OF 2 APS-SA/DA P POTTER Addressable Pull Station ® The Symbol of Protection Single/Dual Action Setting the Address The APS Series uses one SLC address which must be assigned prior to installation of the device.The address is set using either the handheld device programmer or the device addressing feature built into each Potter fire alarm control panel. Pull Station Front View IMO AR' FRFE 0 Ai' *ot,. .HAIi tae VIC I 41171111 _ I ' Nll U APS-DA APS-SA Pull Station Back View and Wiring 0 O NDC S4S- ii\\fl /l.i►JJ 741i • FROM FACP OR PREVIOUS DEVICE TO NEXT DEVICE FACTORY WIRED CONTACTS 0 6 Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-1211 /Customer Service: 866-572-3005 • www.pottersignal.com Iso 9001:2008 I DESIGNING,MANUFACTURING, CERTIFIED &DISTRIBUTING QUALITY SYSTEMS 8830052-REV B • 10/14 PAGE 2 OF 2 • P POTTER® SCM-4 The Symbol of Protection Single Contact Module Features • One Class B(Style B)contact monitoring input • Powered directly from 2 wire SLC Loop lb 41. • SLC Class A(Style 6,7)&Class B(Style4) • Mounts on a standard 4"or double gang box `" S • Wiring terminals accessible when mounted in box s- „*. ':.. ' • Wiring terminals accept 22 to 14 AWG ISmit. ... ..+o.... rho- �wmmyw • Product includes a 5 year warranty 4111r—'* l NOTE:This addressable module does not support 2-wire smoke 2 c detectors. - Stock Number: 1430821 STS C (13 US \��� 3@R•V 1V4 LISTED S2930 7165-0328:0196 Application Technical Specifications The SCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.0V 8500 addressable fire alarm control panels. The SCM-4 is a contact Max SLC Standby Current 325µA monitor module used to supervise a circuit of dry contact input devices Max SLC Alarm Current 1mA such as; sprinkler water flow,valve tamper switches or conventional pull stations. Max Wiring Resistance of IDC 10052 Max WiringCapcitance of IDC 1µF EOL Resistor 5.1K0 Description Max no.of SCI on SLC loop in The SCM-4 module uses one(1)address on an SLC loop.The module Class A 64 Units is used to supervise a Class B circuit of normally open, dry contact Operating Tempurature Range 32 to 120°F(0 to 49°C) input devices.The SCM-4 module includes one red LED to indicate o the modules status. In normal condition,the LED flashes when the Operating Humidity Range 0 to 93/a(non-condensing) device is being polled by the control panel.When a device is activated, Max no.of Modules per Loop 127 units the LED will light continuously.In case of an open circuit,the LED 4.17”(106mm)L x 4.17" will turn off. Dimensions (106mm)W x 1.14"(29mm) Mounting Options Standard 4"Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830006-REV D • 7/14 PAGE 1 OF 2 P POUERWDHMI SCM The Symbol of Protection Single Contact Module Setting the Address Each SLC device must be assigned an address prior to installation.The address is set using either the hand held device programmer or the addressing feature on the PFC-6000/PFC-8500 Series control panels. Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box 4 'or: o „0,7<, e C O ° b I • o 411'911 O Wiring Diagram Note:The resistance of external wiring shall be less than 1008. The capacitance of external wiring shall be less than 1 micro farads. E � � I 5.180 1/2W EOLR COM To Next Module 5+ NO : Z 51.0l^ C Loop �'".�LEo,• Single Contact Module From FACP or Previous Module Model No.SCM-4 DWG#593-14 Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008 DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 8830006-REV D • 7/14 PAGE 2 OF 2 • P POUER.iVa#.iMI DC M-4 The Symbol of Protection Dual Contact Module Features • Single module with dual contact monitoring inputs110 . • Two(2)Class B or one(1)Class A monitoring inputs • SLC Class A(Style 6,7)&Class B(Style4) • Mounts in a standard 4"or double gang box x- s: • Wiring terminals accessible when mounted in acc4,0 w..a..ka.ra..w. • All wiring terminals accept 22 to 14 AWG t 1 mm • Product includes a 5 year warranty NOTE: This addressable module does not support 2-wire smoke 1 Z2-1% caP1 Cl- detectors. . Stock Number: 1430822 C DS ! LISTED S2930 7165-0328:0196 Application Technical Specifications The DCM-4 is compatible with Potter's PFC-6000 series and PFC- Operating Voltage 22.0-24.0V 8500 addressable fire alarm control panels.The DCM-4 is an interface Max SLC Standby Current 325µA module used to monitor dry contact devices such as sprinkler water Aux Power Required 1mA flow,valve tamper switches,or conventional pull stations.The module is capable of monitoring two separate Class B or one Class A circuits. Max Wiring Resistance of IDC 100 S2 Max Wiring Cpacitance of IDC 1µF EOL Resistor 5.1K Q Description Operating Tempurature Range 32 to 120°F(0 to 49°C) The DCM-4 uses two (2) consecutive SLC loop addresses when Operating Humidity Range 0 to 93%(non-condensing) monitoring two(2)Class B circuits or one(1)address when monitoring 127 units(Class A)or 63 units a single class A(Style D)circuit.The module mounts on either a 4" Max no.of Module Per Loop (Class B) square or double gang box.The module is capable of monitoring two (2)separate class B circuits making it ideal for monitoring sprinkler Dimensions 4.17"(106mm)L x 4.17" waterflow and valve tamper switches when they are located in the same (106mm)W x 1.14"(29mm)D proximity.The DCM-4 includes one red LED to indicate the modules Standard 4"Square or status.In normal condition,the LED flashes when the device is beingMounting Options Double Gang Box polled by the control panel.When a contact is activated,the LED will Shipping Weight 0.6 lbs light continuously and in case of an open circuit,the LED will turn off. - Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com 8830008-REV B • 7/14 PAGE 1 OF 2 P POTTER.IsJoI-IMI D -4 The Symbol of Protection Dual Contact Module Setting the Address Each addressable module,smoke sensor,heat detector and combination sensor/detector must be assigned an address prior to installing the device.The address is set using either the hand held device programmer or the addressing feature on the PFC 6000/PFC 8500 Series control panels.When the DCM- 4 is used to monitor two individual Class B circuits a single device address is assigned,with the second address number assigned automatically by the module assuming the next consecutive address.For example,if the first address number is assigned as"2",the second address number will automatically be assigned as SLC device address"3". Before connecting a device to the SLC loop,take the following precautions to prevent potential damage to the panel or device verify the following: 1.Power to the device is removed 2.Field wiring is correctly installed. 3.Field wiring has no open or short circuits. Installation Using Compatible Electrical Box o LA b o O �0b Wiring Diagrams DCM-4 With One ClassA Circuit It FROM FRCP OR Z1 ::M1111211 PREVIOUS MODULE ��S+ Zl S- NO2 1,11, TO THE NEXT MODULE JPplp C2 41•;, 0000 LED 0 Z2 SELECT STYLED 0000 NOTE:END-OF-LINE RESISTOR IS NOT REQUIRED DCM-4 With Two Class B Circuits FROM FACP OR CI PREVIOUS MODULE i�S+ Zl hEND-OF-LINE RESISTOR 5.1K OHM 1/2W S- NO2 It; TO THE NEXT MODULE JP1 C2 nein iLED0 Z2 SELECT STYLE B END-OF-LINE RESISTOR 5.1K OHM 1/2W Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008DESIGNING,MANUFACTURING, CERTIFIED I&DISTRIBUTING QUALITY SYSTEMS 8830008-REV B • 7/14 PAGE 2 OF 2 P POTT ER S-24 & HS-24 SELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Features • 24VDC units have field selectable candela options of 15,30,60, 75,&110 • Super-Slide®Bracket-Ease of Supervision Testing • Checkmate®-Instant Voltage Verification • Synchronize strobe and/or horn with AVSM Control Module • Prewire entire system,install mounting bracket,then install ., signals Documented lower installation and operating costs @' 1'f ,` ° "` • Input terminals accept 12 to 18 AWG z - . • Switch selection for high or low dBA ( • Switch for chime,whoop,mechanical and 2400Hz tone 1Tamperproof re-entrant style grill • Switch for continuous or temporal 3 tone(not available on whoop E tone) • Surface mount with the AVBB(Surface Mount Back Box) • Silence audible while visual appliance will remain flashing(for use in accepted jurisdictions) • Faceplate available in red or off-white Operating Temperature • 32°F to 120°F(0°C to 49°C).The HS and S Series are not listed for outdoor use. Unit Dimensions • 5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5"(6.35 cm)deep UL0 LISTED S3247 Description The S-24/HS-24 Series is a low profile strobe and horn/strobe This Series is shipped with a standard 4" metal mounting combination that offers dependable audible and visual alarms and the plate which incorporates the popular Super-Slide®feature that allows absolute lowest current available. the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without The S-24 & HS-24 Series 24VDC offers tamperproof field any screws showing. selectable candela options of 15,30,60,75,and 110 candela. The S-24/HS-24 also features the patented Checkmate® - The Strobe and Horn/Strobe offers a continuous or sync Instant Voltage Verification feature which allows the installer to check temporal three in 2400Hz and mechanical tone, a chime and whoop the voltage drop draw and match it to the blueprint. tone.All tones are easy for the professional to change in the field by the use of switches. The S-24&HS-24 Series appliances are ANSI/UL 464 and ANSI/UL 1971, listed for use with fire protective systems and are The S-24 & HS-24 Series has a minimal operating current warranted for three years from date of purchase. and has a minimum flash rate of 1Hz regardless of input voltage. PotterElectric Signal Company,LLC•St.Louis,M0 63042 USA•CustService:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 1 OF 4 06/13 PS-24 & HS-24 PJTTER SELECTABLE CANDELA e The Symbol of Protection STROBE & HORN/STROBES Tone Switch Locations TONE SWITCH POSITION . 3 4 I 5 cE—•■ ■■ Mechanical Temporal 3 ON ON ON N■ ■■ - Mechanical-Continuous OFF ON ON cEw■ ■■ p Sa) r 2400Hz-Temporal 3 ON OFF ON 2400Hz-Continuous OFF OFF ON a NI ■■ 1=1 �S.( C Chime-Temporal 3 ON ON OFF [u ■ ■■ ]=I1{+ hh Chime-Continuous OFF ON OFF crcb■ ■■ 1= i 11- Whoop ON OFF OFF ® 1 t/ Whoop OFF OFF OFF _,/ NOTE: • Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Super Slide®Mounting Bracket / - -1 Checkmate®Instant Allows the installer to pre-wire 1 Voltage Verification the system,test for system .1 It is often necessaryto confirm the voltage Y Y I11\ g supervision,remove the signal it ' drop along a line of devices.The access t.head until occupancy,switch ) ��, holes are provided in the back of the out signals without terminal block to allow the voltage to be changing mounting brackets t1 l f iv I measured directly without removing the and has locking edge connector ('1111 11` -'■. 4 device.Typically,this would be done at the for snap-in-place installation. III 111 end of line to confirm design criteria.Most measurements will be taken using the S+ •% and S-locations althouhg access is provided • •��r to other locations. NOTE:Care should be taken to not short the test probes. Candela selection slider switch. Depress center and slide switch to desire brightness level. _......-----7— " •,,R.• ,, it' 7 ..„-- \A Break off pin and insert _ II�! I j into hole at the bottom of �' ��` ., �V • the selector to lock I t candela setting.Signal I `. 111 k i must be removed from �. �' h____, o�� W i ��� � F bracket and pin pushed IF 1111 ( 1 4 sl ,l forward from backside out `'1 )` � I,I ` 1 i - of hole to change candela. I J ? ; . --_ 'moi To remove bezel,grip both sides of bezel and pull in a download and outward motion. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA.Cust Service:866-572-3005*Tech Support:866-956-0988•Canada 888-882-1833-www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 2 OF 4 06/13 P P011ER S-24 & HS-24 ECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES S-24 24 VDC Selectable Candela,Low Profile Evacuation Strobe • Model Part Nominal Candela Number Number Voltage (ANSI/UL 1971) \ ` S-24WR 4890010 24 VDC 15,30,60,75, 110 S-24WW 4890011 24 VDC 15,30,60,75, 110 HS-24 24 VDC Selectable Candela,Low Profile Evacuation Horn/Strobe Model Part Nominal Candela Reverberant dBA at In Anechoic Room Number Number Voltage (ANSI/UL 1971) 10 ft.,per ANSI/UL 464 dBA at 10 ft. \ - HS-24WR 4890030 24 VDC 15,30,60,75, 110 62-82 100 y HS-24WW 4890031 24 VDC 15,30,60,75, 110 62-82 100 S-24&HS-24 Product Strobe Current Ratings(mA) 24 VDC(16-33 Volts) Model Designations: W=Wall Mount Candela 24 VDC UL Maxi R=Red Faceplate W=White Faceplate 15 cd 30 mA 42 mA 30 cd 35 mA 58 mA All units are available in plain(no lettering). Plain units are non-returnable. 60 cd 66 mA 97 mA 75 cd 80 mA 116 mA ALERT bezel available for order. 110 cd 103 mA 161 mA ALERT bezel available for order. S-24&HS-24 Product Horn Current Ratings Horn Decibel Levels Horn Current Ratings Minimum SPL Minimum SPL Regulated 24 VDC Horn Mode at 10 ft.,per at 10 ft.,per Max.Operating (z' ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400 Hz 78 dBA 71*dBA 28 mA Temp 3 Mechanical 76 dBA 70*dBA 25 mA Temp 3 Chime 70*dBA 66*dBA 15 mA Continuous 2400 Hz 81 dBA 74*dBA 28 mA Continuous Mechanical 80 dBA 72*dBA 25 mA Continuous Chime 70*dBA 66*dBA 15 mA Whoop 82 dBA 69*dBA 56 mA NOTES: • For nominal and peak current across ANSI/UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified]) power,see installation manual. • Potter does nto recommend usign a coded or pulsing signaling circuit with any of our strobe products. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application(not applicable when using the chime tone.The chime tone is always private mode). PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA-CustService:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 3 OF 4 06/13 S-24 & HS-24 PPOERSELECTABLE CANDELA The Symbol of Protection STROBE & HORN/STROBES Architect&Engineering Specifications The audible and/or visible signal shall be Potter S-24 strobe and Potter HS-24 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with Factory Mutual Listing Service(FM)and the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 21-z regardless of power input voltage.The strobe appliance shall have an operating current of 42mA or less at 24VDC for the l5Cd strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control Control Panel Signal Signal Signal Signal S+ S+ S- H+ H- S+ S+ S- H+ H- Panel S+ s+ S- H+ H- S+ S+ S- H+ H- Supervised •r3 y •141. Supervised o ;, ® ® o o " B 0 Signal Circuit " ' 111„ Signal Circuit , 'l \ 0 I"11M1ii" 1"' END OF L NE O END OF UNE \ RESISTOR I I RESISTOR I ' " / \ O END LINE RESISTOR Q NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. PotterElectric Signal Company,LLC•St.Louis,MO 63042 USA•CustService:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833.www.pottersignal.com PRINTED IN USA MFG.#8830054-REV A PAGE 4 OF 4 06/13 P POTTER S24-177/HS24-177 The Symbol of Protection High Candela Strobe and Horn/Strobe Features • Nominal Voltage 24 VDC • Fixed177 candela strobe ) y 't • Super-Slide®Bracket-ease of supervision testing011111 r • Checkmate®-Instant voltage verification ,M.41fAltiv, r • Unit Dimensions:5"(12.7 cm)high x 4.5"(11.43 cm)wide x 2.5" (6.35 cm)deep. • Synchronize strobe and/or horn with AVSM Control Module • Pre wire entire system,install mounting bracket,then install signals E E • Documented lower installation and operating costs -e • Input terminals 12 to 18 AWG - • Switch selection for high or low dBA • Switch for chime,whoop,mechanical and 2400Hz tone • Switch for continuous or temporal 3(not available on whoop tone) • Tamper proof re-entrant grill • Surface mount with the AV BBCI) ) • Silence horn while strobes remain flashing LISTED • Faceplate available in red or off-white S3247 7135-0328:0217(HS24-177) 7125-0328:0216(S24-177) _ Applications Product Listings The S/HS24-177 Series is a low profile strobe,or horn/strobe • ANSI/UL 464,ANSI/UL 1971 and/or ANSI/UL 1638 Listed - combination that offers dependable audible and visual alarms with the absolute lowest current available. Product Compliance • NFPA 72 The S/HS24-177 Series has a minimum flash rate of 1Hz regardless of input voltage. • Americans with Disabilities Act(ADA) • IBC/IFC/IRC The S/HS24-177 Series is shipped with the standard 4"mounting plate which incorporates the popular Super-Slide®feature that allows the • City&State Ordinances/Laws/Regulations installer to easily test for supervision.The product also • Quality Management System is certified to:ISO 9001:2008 features a locking mechanism which secures the product to the bracket without any screws showing. The S/HS24-177 Series also features the patented Checkmate®-Instant Voltage Verification feature which allows the installer to measure the voltage drop and match it to the blueprint. The S/HS-177 Series appliances are ANSI/UL 464,ANSI/UL 1971 and/or ANSI/UL 1638 listed for use with fire protective systems and are warranted for five years from date of purchase. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com PRINTED IN USA MFG.#8830066-REV A • 5/14 PAGE 1 OF 4 P P POTTER S24-177/HS24-177 The Symbol of Protection High Candela Strobe and Horn/Strobe Tone Switch Locations SWITCH POSITION TONE e-■ 3 4 5 C:EM ■■z� Mechanical Temporal 3 ON ON ON Mechanical-Continuous OFF ON ON N■ UI b AP 2400Hz-Temporal 3 ON OFF ON cE w■ ■■ p ' S+ i iF 24001-1z-Continuous OFF OFF ON Chime-Temporal 3 ON ON OFF um Chime-Continuous OFF ON OFF u'■ ■■ Mma H+ lig Whoop ON OFF OFF [0 . •• I a4- a Whoop OFF OFF OFF ® J eel7 NOTES: • Switch Positions 1 and 2 in the OFF position to A select isolated horn and strobe power inputs • Switch Position 6 ON=HIGH dBA • Switch Position 6 OFF=LOW dBA Checkmate® Instant Super Slide® Mounting Voltage Verification Bracket It is often necessary to confirm the voltage Allows the installer to pre-wire41111° drop along a line of devices.The access the system,test for system holes are provided in the back of the supervision,remove the signal 1 terminal block to allow the voltage to be - head until occupancy,switch measured directly without removing the out signals without `` device.Typically,this would be done at the - changing mounting brackets end of line to confirm design criteria.Most and has locking edge connector measurements will be taken using the S+ for snap-in-place installation. and S-locations although access is provided i to other locations. i+ NOTE:Care should be taken to not short the test probes. li pr- y 1/.. . Tr 1. 1 I1 ' .1 Ili 17-=.Q.,_.. Nom domb Al=M" IA '1, rit 1 ri P 4, alli 1 il-1'1'1') I: To remove bezel,grip both sides of bezel and pull in a download and outward motion. - Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com PRINTED IN USA MFG.#8830066-REV A • 5/14 PAGE 2 OF 4 P POTTER S24-177/HS24-177 The Symbol of Protection High Candela Strobe and Horn/Strobe S24-177 VDC Low Profile Evacuation Strobe Model Number Item Number Nominal Strobe Model Designations: Alert Bezel Available: Voltage Candela Red-4890264 S24-177R 4890014 24 VDC 177 P=Plain(no lettering) White-4890265 ' S24-177W 4890015 24 VDC 177 R=Red faceplate W=White Faceplate. Agent Bezel Available: Red-4890262 S24-177PR 4890016 24 VDC 177 Plain units are non-returnable. White-4890263 S24-177 PW 4890017 24 VDC 177 HS24-177 24 VDC Fixed Candela, Low Profile Evacuation Horn/Strobe Nominal Strobe Reverberant dBA @ In Anechoic Room Model Number Item Number Voltage Candela g 10ft.,per ANSI/UL 464 dBA @ 10ft. \\ HS24-177R 4890034 24 VDC 177 70-82 100 HS24-177W 4890035 24 VDC 177 70-82 100 HS24-177PR 4890036 24 VDC 177 70-82 100 HS24-177PW 4890037 24 VDC 177 70-82 100 S/HS24-177 Series Current Ratings (mA) 24VDC(16-33 Volts) II HS-24 Horn Decibel and Current Ratings Candela 24 VDC UL Maxi Minimum dBA Minimum dBA Regulated 12VDC @ lOft.per @ lOft.per _ l 177cd 96mA 213mA I Horn Mode Max.Operating @ ANSI/UL 464 ANSI/UL 464 High Setting(mA) (HIGH) (LOW) Temp 3 2400Hz 78 71* 28 Temp 3 Mechanical - 76 70* 25 Temp 3 Chime 70* 66* 15 Continuous2400Hz 81 74* 28 Continuous Mechanical 80 72* 25 Continuous Chime 70* 66* 15 Whoop 82 69* 56 NOTES: • Operating temperature:32°to 120°F(0°to 49°C).The 177 Series is not listed for outdoor use. The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating.While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered(FWR[Full Wave Rectified])power,see installation manual. * Operating the horn in this mode at this voltage will result in not meeting the minimum ANSWL 464 reverberant sound level required for public mode fire protection service.These settings are acceptable only for private mode fire alarm use.Use the high dBA setting for public mode application (not applicable when using the chime tone.The chime tone is always private mode). ' RMS current ratings are per UL average RMS method.UL max current rating is the maximum RMS current within the listed voltage range(16- • 33VDC for 24VDC units).For strobes the UL max current is usually at the minimum listed voltage(16VDC for 24VDC units).For audibles the max current is usually at the maximum listed voltage.For unfiltered FWR ratings,see installation manual. Potter Electric Signal Company,LLC • St. Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com PRINTED IN USA MFG.#8830066-REV A • 5/14 PAGE 3 OF 4 P POTTER S24-177/HS24-177 The Symbol of Protection High Candela Strobe and Horn/Strobe Architect & Engineering Specifications The audible and/or visible signal shall be Potter S24-177 strobe and Potter HS24-177 horn/strobe Series or approved equal and shall be listed by Underwriters Laboratories,Inc.per ANSI/UL 1971 and/or ANSI/UL 464.The notification appliance shall also be listed with the California State Fire Marshal(CSFM). The notification appliance(combination audible/visible)shall produce a peak sound output of 100dBA or greater at 24VDC as measured in an anechoic chamber.The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires.Additionally,the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. Unit shall be capable of being installed so that any unauthorized attempt to change the candela setting will result in a trouble signal at the fire alarm control panel. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1Hz or up to 2Hz regardless of power input voltage. The appliance shall be polarized to allow for electrical supervision of the system wiring.The unit shall be provided with a mounting bracket with terminals and barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox without the use of an adapter plate.The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power for 24VDC models. The appliance shall be capable of testing supervision without disconnecting wires,verify voltage without removing unit and be capable of mounting to a surface back box. Conventional Wiring Diagrams for Emergency Notification Evacuation Series UL Listed UL Listed Control • Control Panel Signal Signal Panel Signal Signal S+ S+ S- H+ H- S+ S+ S- H+ H. S+ S- H+ H- S+ S+ S- H+ H- Supervised t"-=k1, :� y y Supervised . 2 e e . o ;, e e Signal Circuit "I"' 111" Signal CircuitND 11OF \\\ f I I \ '�" 1 ERESISTORE I END OF LIN RESISTORE , O mei / I �"11 \ O I END LINE RESISTOR O NOTES: • All strobes are designed to flash as specified with continuous applied voltage.Strobes should not be used on coded or pulsing signaling circuits.However,use of the Potter AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe,horn,and/or mute the horn. • FOR SYNCHRONIZATION WIRING INFORMATION,REFERENCE AVSM CONTROL MODULE DATA SHEET(8830064) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS.AVSM CONTROL MODULE DATA SHEET CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936. Potter Electric Signal Company,LLC • St.Louis,MO • Tech Support: 866-956-0988/Customer Service: 866-572-3005 • www.pottersignal.com PRINTED IN USA MFG.#8830066-REV A • 5/14 PAGE 4 OF 4 • WIRE GUARDS HORN /STROBE/SPEAKER DAMAGE STOPPERS® „............. _ ir iiiiiivii", 111 11 III _z ii, i,. c UL us iiii,,itin" , A,,Ato, ....•....,+� STI-9705-R STI-9711 • . "=b'-a 4.At Ukt • Mote 111114 IIII • li'' -., III ' ' KEY FEATURES 3 General Information u*24 s> #,yr• Offers protection against vandalism c to STI-9720 and accidental damage. •Simple removal for maintenance. Three year guarantee against breakage in normal use. PRODUCT OVERVIEW Construction Here are excellent ways to protect strobe units against both vandalism and accidental Constructed of tough 9-gauge steel wire. damage. Constructed of tough, 9-gauge steel wire coated with corrosion resistant red .Coated with corrosion resistant or white polyester,these guards can take hard knocks in stride. STI-9705, STI-9708, polyester. STI-9711 and STI-9714 wire guards provide maximum protection for System Sensor Installation SpectrAlert®Advance series strobe notification appliances. •Installation is fast and simple with screws and anchors provided. BACKED BY A THREE YEAR GUARANTEE Options •As all STI protective covers,these guards are backed by a three year guarantee against STI-9705,4protect SpSTI-9708, ctrSTIA ler° and STI-9714 SpectrAlert breakage in normal use. Installation and servicing is easy with all screws and anchors strobe units. provided. This Stopper is highly recommended for areas where abuse is severe or it is • STI-9717 and STI-9720 fit over imperative that strobe units continue to operate. STI-9717 and STI-9720 fit over System appliancespptem Ss soP2 notification R1224MC and . Sensor notification appliances SP2R1224MC and SP2W1224MC. SP2W1224MC. www.sti-usa.comU For more information,call 1-800-888-4784(4STI)or visit Safety Technology ..• 1,o. , International,Inc. ❑ , Horn/Strobe/Speaker Damage Stoppers° Dimensions and Technical Information STI-9705 Damage Stopper,Flush Mount-White TESTING " y STI-9705-R Damage Stopper,Flush Mount Red STI-9705,STI-9708,STI-9711 and STI-9714 have been tested and STI-9708 Damage Stopper,Surface Mount-White • STI-9708-R Damage Stopper,Surface Mount-Red approved or listed by: STI-9711 Damage Stopper,Flush Mount White •Underwriter Laboratories and Canadian UL File S7025 STI-9714 Damage Stopper,Surface Mount-White WARRANTY STI-9717 Speaker/Strobe Damage Stopper-Flush Mount Three year guarantee against breakage in normal use. (not UL Listed) STI-9720 Speaker/Strobe Damage Stopper-Surface Mount Light De-Rating Factor Light Loss (not UL Listed) STI-9705 and STI-9708 °70 System Sensor(SR,SW, SW-ALERT, SW-CLR-ALERT, SRK, 13% MODEL HEIGHT WIDTH DEPTH SWK, P2R, P2W, P4R, P4W, CHSR, CHSW, P2RK, P2WK, P4RK, P4WK, SPSR, SPSR-SP, SPSR-PG, SPSW, SPSW- STI-9705CLR-ALERT, SPSW-SP, SPSW-PG, SPSRV, SPSRV-SP, STI-9705-R 7.40 in.(188mm) 6.15 in.(156mm) 3.39 in.(84mm) SPSRV-PG, SPSWV, SPSWV-SP and SPSWV-PG, SPSWK, STI-9708 SPSRK,SPSW-ALERT) STI-9708-R 7.49 in.(190mm) 6.74 in.(171mm) 6.09 in.(155mm) System Sensor (SRH, SWH, SRHK, SWH-ALERT, SWHK, 0% STI-9711 8.26 in.(210mm) 8.26 in.(210mm) 3.54 in.(90mm) P2RH,P2WH,P4RH,P2RHK,P2WHK,P2RHK-120,SPSRH, .ee i SPSRH-SP,SPSRH-PG,SPSWH,SPSWH-SP and SPSWH- STI-9714 8.55 in.(271mm) 8.55 in.(271mm) 6.23 in.(158mm) PG,SPSRHK) ' STI-9717 6.1 in.(155mm) 9.3 in.(238mm) 2.4 in.(61mm) STI-9711 and STI-9714 STI-9720 6.1 in.(155mm) 9.3 in.(238mm) 4.9 in.(125mm) System Sensor (SCR, SCW, SCRK, SCWK, SCW-CLR- 0% _ ALERT, PC2R, PC2W, PC4R, PC4W, PC2RK, PC2WK, I■I■I�_��I■I■I PC4WK, SPSCWV, SPSCR, SPSCR-SP, SPSCR-PG, I,I'� �,I,I SPSCW, SPSCW-SP, SPSCW-PG, SPSCRV, SPSCRV- PG, SPSCWV, SPSCWV-SP and SPSCWV-PG, SPSCWK, SPSCW-CLR-ALERT) 11111 11111 I (jg8mm) System Sensor (SCRH, SCWH, SCRHK, SCWHK, PC2RH, 0% BIM J�I�I u I I PC2WH,PC4RH,PC2RHK,PC2WHK,PC4WHK,SPSCWHV, SPSCRH,SPSCRH-SP,SPSCRH-PG, SPSCWH,SPSCWH- SP, �I� �P l 1, SP,SPSCWH-PG,SPSCRVH. SPSCWHV-SP SPSCWHV PG,SPSCWHK)P,SPSCRVH PG, 6.15 in. X3.39 in.�I 11111 1.1111.1.11.1(156mm) (86mm) _ 511-9705 IUI 1.111111=1.1 3.7 in. 3.15 in. 1.63 in. IMI 1=IIMI (9491m)1"-(80mm) (41 mm) 11 '1 IniiM11l i•i=li•111111NI 4.9 in. �i (125mm) 4-110-0k �I I -I STI-9720 3 Itl�I �I�I 7.49 in. II■I�I�� TOP VIEW (79mm) I1I1I I1I1I (190mm) I■I•I■I II II II II II II II II II t I1I� 1I1I I■I.1I■1 J II II (31:12,1)(61mm) in. J- 1 Mil IP 911111.1 511-9717 6.74 in. 6.09 in. I TOP VIEW (171mm) STI-9708 (155mm) 9.3 in.(238mm) [4.1■■■■■_■_�.. ��\��/\ � •....•-.. 6.1 in. /���,�� ��..‘- 8.26 ._■_■_■_■ (155mm) �ll�Ia�VA �������II 8.26 in. tjiJ n8.55in. M■■■■ ," (210mm) (271mm) ----- a zs° .3 54 in..i- STI-9717 and STI-9720 (90mm) (158mm) FRONT VIEW " ST1-9711 • / 2306 Airport Road Tel:248-673-9898 Unit 49G Pipers Road Tel:44(0)1527 520 999 ° Safety Technology Waterford,Michigan Fax:248-673-1246 Park Farm Industrial Estate Fax:44(01 1527 501 999 SrJ,1 International, Inc. 48327,USA Toll-free:800-888-4784 Redditch,Worcestershire info@sti-europe.com info@sti-usa.com B98 OHU England www.sti-europe.com www sti-usa.com Printed in U.S.A.,©1987-2009 Safety Technology International,Inc. Subject to change without notice. 08/15