Plans
r # .1GENERAL NOTES AERIAL VIEW OFFICE COPY ' 1. ALL WORK SHALL COMPLY WITH 2014 NATIONAL ELECTRIC CODE(NEC),2014 NATIONAL •" 3r # v~,t BLUE RAVEN BUILDING CODE(NBC),2015 INTERNATIONAL BUILDING CODE(IBC).2015 INTERNATIONAL ' '' _,:,::„E„, PLUMBING CODE(IBC),AND ALL STATE AND LOCAL BUILDING,ELECTRICAL,AND PLUMBING i 'fit tt CODES. it- : � i c.� 2. DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. • .„ * . SITE NOTES N 1 U 2016 1220 S.630E STE.430 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. *. g ..JAMERICAN FORK,UT 84003 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY 1' ", 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR i w _ t: ) t � , UERA ENSO INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. ` `° < ? WWW.BLUERAVENSOLAR.COM BUILDING ROOF VENTS. " ftTf°° r ,- CONFIDENTIAL-THE INFORMATION 4. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL # R HEREIN CONTAINED SHALL NOT BE EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26] w # 41141111114USED FOR THE BENEFIT OF 5. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE g ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BETWEEN THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER)IF SMALLER THAN#6 r _ # 'Ili 'l:;z. BE DISCLOSED IN WHOLE OR IN AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE CONDUCTOR WILL BE x. • ! - p PART TO OTHERS OUTSIDE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER = RECIPIENTS ORGANIZATION, [NEC 250.64C.] a; EXCEPT IN CONNEC TION WITH THE � SALE AND USE OF THE RESPECTIVE 6. ROOF COVERINGS SHALL BE DESIGNED.INSTALLED,AND MAINTAINED IN ACCORDANCE WITH is*=' ] #s g t EQUIPMENT,WITHOUT THE THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF17-- : a` + 1 H , WRITTEN PERMISSION OF COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. E 3 °]I° + a ' BLUERAVENSOLAR LLC. 7. RIGID CONDUIT(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROTECT WIRES. I , #_ $L _ 8. BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED " v "` g § W O COO CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) , t 4. :' W d J 4711'*4 9. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS O Q DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED } CO c . . O C'') Z . t (X Z SOLAR CONTRACTORco ,ff , " r . .... Lo LL[ O 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. r 00 i co z 5 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING �F �' - U 0 Q LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS. « x, 4.`; «" $� ! W U U 3. AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION # * AND APPROVED BY THE AHJ. 'w m w ''0. �* . 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE t. NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. 'x i^ , 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND j .. SEALED WITH A SUITABLE SEALING COMPOUND. ,Z, T 14 • 6. DC WIRING LIMITED TO,MODULE FOOTPRINT W/ENPHASE AC SYSTEM. . '� ' 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ � Tb .! Q SUITABLE WIRING CLIPS. 0 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR 0 J VOC UNLESS NOT AVAILABLE. SHEET INDEX 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES,PHOTOVOLTAIC PANELS, ASCE 7-10 WIND SPEED: 110 MPH OCCUPANCY - R3 o AC PHOTOVOLTAIC MODULES.SOURCE CIRCUIT COMBINERS,AND CHARGE CONTROLLERS GROUND SNOW LOAD: 10 PSF CONSTRUCTION - V-B PV1 - COVER SHEET Z co FOR USE INA PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR 0 O N THE APPLICATION PER 690.4(D). EXPOSURE CATEGORY: C ZONING: RESIDENTIAL PV2 - PROPERTY PLAN N 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. SEISMIC DESIGN CATEGORY: D PV3 - SITE PLAN u) EQUIPMENT LOCATIONS PV4 - EQUIPMENT & ATTACHMENT DETAIL N U 1. ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY[NEC 110.26]. SCOPE OF WORK PV5 - ELECTRICAL SINGLE LINE DIAGRAM 0 � N W 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING PV6 - ELECTRICAL CALCULATIONS > O DC SYSTEM SIZE: 5.22 kW DC Z_ TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)]AND[NEC TABLE 310.15(B)(2)(C)]. & STRING DIAGRAM co 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT ROOF TYPE: Comp Shingle co W '- TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. PV7 - MBD CALCS. (I F NEEDED) _� 0 N 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO ANCHORED ON MAX 48 INCH CENTERS USING UL LISTED RACKING PV8 - LABELS & LOCATIONS 0 .,;1-- ~ a Lo NEC APPLICABLE CODES. PV9 - PLACARD DRAWING BY SYSTEM TO SPEC. 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. UV RESISTANT CABLE TIES(NOT ZIP TIES) USED FOR PERMANENT Carson Hawkes WIRE MANAGEMENT OFF THE ROOF SURFACE IN ACCORDANCE CITY OF TIGARD DATE WITH NEC 110.2,110.3(A B). 300.4 REVI FOR CODE COMPLIANCE October 28, 2016 SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE WILL BE USED IF CONDUIT RUN DETERMINED IN THE FIELD TO BE Approved: 3 PROJECT NUMBER RAN THROUGH ATTIC. DC CONDUCTORS SIZED WITH DERATES TO OTC: ( j 25233480 1/2" ABOVE ROOF SURFACE PER NEC 310.15(8}(3)(C) Pcrmt#: pi..5-t oto I{, - Ob 4�a SHEET NAME MODULE: (18) Sunmodule Plus SW 290M Black Address: 17S .s„, w r.� Gk - /p COVER SHEET INVERTER(S): SolarEdge SE5000A-US,---- Suite#: PAGE NUMBER REVISION RACKING: Iron Ridge XR10 PV Mounting & Racking System By: ' Dates �- g- PV1 [ LEGEND INV INVERTER&DC DISCONNECT LU E RAVEN 11756 Southwest Swendon Loop SUB (E) SUBPANEL 1220 S.630E STE.430 LC (N) LOAD CENTER AMERICAN FORK,UT 84003 800-3774480 AC AC DISCONNECT VVWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE M UTILITY METER/SERVICE PANEL USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT JB JUNCTION BOX BE DISCLOSED IN WHOLE OR IN FRONT OF HOME PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE PV PV REVENUE METER SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF N a FIRE SETBACK BLUERAVENSOLAR LLC. I / ❑ _ -- .'-10" L } o LEt09 PV SOLAR MODULE WyW LU .- O < 7h © C0Zd- d 0 M DC) Q ° ti AC EMT CONDUIT RUN Q 0 T o Z M ❑ IN—V (TO BE DETERMINED IN FIELD) 2 i_ Lf) I—Ui C 00 C \.7. O o PV WIRE STRING WQC) Q C116'-4" I PROPERTY LINE 0 D Da m G SCALE: 1116"= 1-0" 0' 4' a 10 02' r:M. '• /• ii• S . O ell -AZ w J o Z "O pigii`'s`i Niiiiii€iiiiii',r": I O_ a) N 0 Q N rn - O tW u) 2 w p MP1 Z co O W AZIMUTH:180° a) >- PITCH:30° H v � a U N U) D - i= D in DRAWING BY Carson Hawkes DATE October 28, 2016 54`SJ'-1 PROJECT NUMBER DC SYSTEM SIZE: 5.22 kW DC 25233480 ROOF TYPE: Comp Shingle SHEET NAME (18) Sunmodule Plus SW 290M Black ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24" ON CENTER IN PROPERTY PLAN SolarEdge SE5000A-US,----INVERTER ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR . PAGE NUMBER REVISION RIDGE PV2 0 i LEGEND INV INVERTER&DC DISCONNECT BLUE RAVEN SUB (E) SUBPANEL 1220 S.630E STE.430 FRONT OF HOME LC (N) LOAD CENTER AMERICAN FORK.UT 84003 800-377-4480 AC AC DISCONNECT WNW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE M UTILITY METER!SERVICE PANEL USED FOR THE BENEFIT OF N ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT JB JUNCTION BOX BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE ❑ PV PV REVENUE METER SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF .7/4 FIRE SETBACK BLUERAVENSOLAR LLC. M o IY >- O LcLg AC ilin PV SOLAR MODULE w z � 0 J i-- N ,r L1_ 1 O o INV Z : c UQD [`- EMT CONDUIT RUN < 0 I (Y Z co. O O (TO BE DETERMINED IN FIELD) 2 I— u., H W F— 00 Z > C) CHIMNEY PV WIRE STRING U O M Q Q WU U � u) W PROPERTY LINE O D J 0_ CO SCALE: 3132"= V-0" 4' 8' 16' O 3' o o V jj/ jj/.if/./ /1/�i.'�Jr i :: / ,e;;;;:::: r/f15,' ''''''' E.•1 I ifil OAR-- —---__-“-,..*„i.i.'1,E.:::,i iii':,;',:*ii;I::..,:ii! !K'!!''''''''' 7//2r11310111,14111111111111111111-111110 i.i�iif:.riz-E'ri SEE iii£ii3'Ei7iEi 12 / W CV A, u) . ._ i=- a L0 DRAWING BY Carson Hawkes M P 1 DATE AZIMUTH:180° —"' 3' October 28, 2016 PITCH:30° PROJECT NUMBER DC SYSTEM SIZE: 522 kW DC 25233480 ROOF TYPE: Comp Shingle SHEET NAME (18) Sunmodule Plus SW 290M Black SITE PLAN PAGE NUMBER REVISION SolarEdge SE5000A-US,----INVERTER PV3 0 PV ARRAY STRUCTURAL CALCULATIONS • PV MODULE Iron Ridge XR10 PV RAIL i_ PV MODULE COUNT: 18 MODULESr; _._. .._.___. �..._ ___. .,,,._rv._. �_ i N ;i L AVEN # OF ATTACHMENT POINTS: 38 1'-11" -- - MAX. 4'-0'" MAX." ARRAY AREA: Module Count X 17.51ft' = 315.2ft' DETAIL, FRONT VIEW 1220 S 630E STE 430 ROOF AREA: 2049ft23/8" = 1, AMERICAN FORK UT 84003 Scale: -0„ 800-377-4480 % OF ARRAY/ROOF: 15.4% WWW.BLUERAVENSOLAR.COM 1 ROOF TYPE:Comp Shingle ASCE 7-10 WIND SPEED: 110 MPH CONFIDENTIAL-THE INFORMATION ARRAY WEIGHT: Module Count x 50Ibs = 900.0Ibs ROOF FRAMING TYPE: Rafters GROUND SNOW LOAD: 10 PSF HEREIN CONTAINED SHALL NOT BE ROOF FRAMING SIZE:2x8 USED FOR THE BENEFIT OF ROOF FRAMING SPACING:24"O.C. ANYONE EXCEPT DISTRIBUTED LOAD: Array Weight - Array Area = 2.86 lbs/ft2 Iron Ridge XR10 PV RAIL BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN IRONRIDGE FLASHFOOT �,� PART TO OTHERS OUTSIDE POINT LOAD: Array Weight _ Attachments = 23.7Ibs/attachment 1'-3" - ' RECIPIENTS ORGANIZATION, MAX. - f ` EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE _ ti EQUIPMENT,WITHOUT THE 1' 3” / WRITTEN PERMISSION OF ---- _ IRONRIDGE END CLAMP IRONRIDGE IG MID CLAMP MAX. 4'-0 MAX." BLUERAVENSOLAR LLC. I PV MODULE FRAME _ PV MODULE FRAME _ "�: z >' p �' IRONRIDGE RAIL IRONRIDGE RAIL W Z ,. O ,_ ...,. t� Z H O fes ,_ , 4' OMAX." Q � � USN- 4 €' rs- QOM a zC2 DETAIL, SIDE VIEW 0 "'co OQc° DETAIL, END CLAMP FRONT DETAIL, MID CLAMP FRONT Scale: 3/8" = 1'-O" LL—.I vv) 0 W ® Scale: 3"= 1'-0" O Scale: 3"= 1'-0" fY J a. co 3'-3" 14'-10" 4'-1" I-- Sunmodule Plus SW 290M Black i PV MODULE o C Iron Ridge XR10 PV IRONRIDGE ,,,-":":°- o -----...._--- ____ .._._____. RAIL _- Z 00 f 0 N W ,, H- CO N- N (E) ROOF e N S 0 2 U O A MEMBRANE in ihill li 1 ` Z o (/)›.. Z Q) us ,C ..�.� r W -8 N- i r . (B N !ice ~ r _� {D N INIIMIIIIIMIIIIIIIMIll 01 c o 7- 0 r '.. DRAWING BY 00, 2 ' MIN. IRONRIDGE Carson Hawkes DEPTH FLASHFOOT ASSEMBLY LBW STRUCTURAL SIDE VIEW DATE Scale: Not to Scale October 28, 2016 5/16"STAINLESS STEEL LAG RAFTER 2x8 @ 24" OC PROJECT NUMBER BOLT AND FLAT WASHER 25233480 (E) BUILDING ROOF ATTACHMENTS SHALL BE SPACED NO GREATER THAN 24" ON SHEET NAMEEQUIP. DETAIL STRUCTURE CENTER IN ANY DIRECTION WHERE LOCATED WITHIN 3' OF A ROOF EDGE, ® DETAIL. STANDOFF PAGE NUMBER REVISION Scale: 3" = 1'-0" HIP, EAVE, OR RIDGE PV4 0 (1) 10 AWG TI4WN 2,COPPER,BLACK(LINE 1) 21 AAC (1) 10 AWG THWN-2,COPPER,RED(POSITIVE) IMP= 7.46 ADC (2) 10 AWG PV WIRE,COPPER IMP= 7.46 A DC (1) 10 AWG -2,COPPER,RED(UNE 2) 240 VAC 0(1) 10 AWG THW N-2,COPPER,BLACK(NEGATIVE) ISC= 15 CO A DC (1) 5 AWG BARE,COPPER(GROUND) ISC= 15 DO A I , • (1) 10 AWG N-2,COPPER,WHITE(NEUTRAL) (1) 10 AWG THWN-2,COPPER.GREEN(EGC) VMP= 35010 V DC VMP= 350V DC \Ow'. • (1) 10 AWGTHWN-2,COPPER,GREEN(GROUND) VOC= 5B0.00 V DC VOC- 500.03 V DC (1) 3/4"EMT CONDUIT (1) 10 AWG T WN-2,COPPER,RED(POSITIVE) IMP= 746 A DC (2) 10 AWG PV WIRE,COPPER IMP= 7.46 A DC BL UE RAVEN (1) 6 AWG THWN-2.COPPER,BLACK(LINE 1) (1) 18 AWG HWN-2,COPPER,BLACK(NEGATIVE) tSC= 15.0D A DC (1} 5 AWG BARE,COPPER(GROUND) SG= 15.1 1 A DC (1) 6 AWG THWN-2,COPPER,RED(LINE 2) � +:1:) VNIP= 350.00 V DC VMP= 350.00 0 V DC 0 (1) 6 AWG THWN-2.COPPER,GREEN(GEC) VOC= -00 V VOC_ .000 V DC (1) 3J4' EMT CONDUIT 1220 S.630E STE.430 AMERICAN FORK UT 84003 800-377-4480 WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE SUPPLY SIDE CONNECTION (18)Sunmodule Plus SW 290M Black EQUIPMENT, UT THE WRITTEN PERMISSSIION OF (E)100A MAIN SERVICE PANEL SolarEdge SE5000A-US 18 P300 SolarEd a DC-to-DC BLUERAVENSOLAR LLC. • (E)100A 12P MAIN BREAKER PER NEC 240.21(B), NEC 705.12(A)&(D) INVERTER JUNCTION BOX ( ) 9 Power Optimizer (E)I AC DISCONNECT — pi � >- o ° rY FUSED 30A,240V (1) STRING W W Q {E)100A/2P 2-POLE. I! G OF 9 MODULES LWJ Ur Z O J el- . ). FUSES AIC 10KA I. Q CO U O r - ' LOADS �2�' 1 _ � I—-- M Z > C) o ❑ [7 FUSES Lz AC I. 30A -o,�c (1) STRING U O 0 Q °�,o u I" 3I I OF 9 MODULES LW, W 0 0 o� o `z Dc o Ui I O D N GEC EGC --�— c, ] LG 3/4"EMT J 120/240 VAC a_ m 60HZ ,4j 3) TO UTILITY GRID I 17'' 15 SIGN LOCATED AT SERVICE EQUIPMENT: G "PHOTOVOLTAIC SYSTEM EQUIPPED WITH RAPID SHUTDOWN" INTEGRATED RAPID SHUT REFLECTIVE ALL LETTERS CAPITALIZED.AT LEASTgi"IN HEIGHT. DOWN DC DISCONNECT AND WHITE WORDING ON A RED BACKGROUND. NEC 690.56(C) SIGN LOCATED AT RAPID SHUT DOWN DISCONNECT CONTROLLER "RAPID SHUTDOWN DISCONNECT" NEC 690.12 Q O 32E- ':S4 0 I (E) GROUNDING —ii ELECTRODE u- c — ss: 0 0 › N W Q U) r` N rn INTERCONNECTION NOTES t 0 N .5 2 U O +� 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF Pp °_ I-1-• 00 0 U) �� BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT i c Z p CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBARfi- c0 N ::: LLI SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES,ONE THE UTILITY p ... .- 3 F— N U CV AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A BUSBAR THAT CONTAINS U) 0 ~ 0 tri LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT CIRCUIT CURRENT AND THE x DRAWING ev RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUSBAR SHALL NOT EXCEED 120 °,.! �( PERCENT OF THE AMPACITY OF THE BUSBAR[NEC 705.12(D)(3)]. Carson Hawkes 3. GROUND FAULT PROTECTION IN ACCORDANCE WITH[NEC 215.9]&[NEC 230.95] DATE 4. ALL EQUIPMENT TO BE RATED FOR BACKFEEDING. 1 1 A 5. SUPPLY SIDE INTERCONNECTION ACCORDING TO [NEC705.12(A)]WITH SERVICE ENTRANCE as3 x October 28, 2016 CONDUCTORS IN ACCORDANCE WITH[NEC 240.21(B)] r PROJECT NUMBER DISCONNECT NOTES '" 25233480 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE ) SHEET NAME TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) °'""` ELEC. 3 LINE DIAG. 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE - LOCKABLE.AND BE A VISIBLE-BREAK SWITCH PAGE NUMBER REVISION 3. DC CURRENT CONDUCTORS ARE TO REMAIN OUTSIDE OF BUILDING PRIOR TO EITHER A FUSEABLE SOURCE CIRCUIT 20 1 r.-1 7.1--3 15'28'42 r --- PV5 0 MODULE'SPECIFICATION:S Sun madule Plus SW 290M Black DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER (STC) 2% W TEMPERATURE DATA SOURCE ASHRAE 2%HIGH TEMP PV MODULES TO SE MAX.SHORT CIRCUIT CURRRENT(ISC)= 9.97 A DC NOV' MODULE VOC 39.9 V DC STATE Oregon OPTIMIZER MAX.CURRENT(ISC X1.2_5)= 12.46 A DC MODULE VMP 31.4 V DC CITY Tigard CONDUCTOR(PV WIRE,( ))= 10 AWG BLUE RAVEN MODULE IMP 9.33 A DC WEATHER STATION PORTLAND INTERNATIONAL AP CONDUCTOR RATING= 40 A MODULE ISC 9.97 A DC ASHRAE EXTREME LOW TEMP('C) -6 AMB.TEMP_AMP-CORRECTION= 0.76 VOC CORRECTION(%J'C) -0.31 'C ASHRAE 2%HIGH TEMP('C) 32 ADJUSTED AMP.= 30.4 > 12.45 1220 S.630 E STE.430 VMP CORRECTION (%/'C) -0.44 'C SE OPTIMIZER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 15.00 A IX AMERICAN FORK,UT 84003 SERIES FUSE RATING 25 A DC SYSTEM ELECTRICAL SPECIFICATIONS MPPT 1 MPPT 2 MPPT 3 JUNCTION BOX MAX.CURRENT(ISC X1-25)= 18.75 A DC 800-377-4480 ADJ.MODULE VOC( ASHRAE LOW TEMP 43.7 V DC STRING SIZE 9 9 CONDUCTOR(PV WIRE,(90'C))= 10 AWG VNNW.BLUERAVENSOLAR.COM ADJ.MODULE VMP 0 ASHRAE 2%HIGH TEMP 26.0 V DC STRINGS IN PARALLEL 1 1 CONDUCTOR RATING= 40 A CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE NUMBER OF MODULES PER MPPT 9 9 AMB.TEMP.AMP.CORRECTION= 0.76 USED FOR THE BENEFIT OF SOLAREDGE OPTIMIZER SolarEdge •' :t4 POWER RATING PER MPPT(STC) 2510 2610 ADJUSTED AMP.= 30.4 > 18.75 ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT RATED POWER INPUT(STC) 1 W TOTAL MODULE NUMBER 18 MODULES DC EGC MAX_CIiANNEL(X1 75) ISC= 19 A DC BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MAX INPUT VOC 48 V DC STC RATING OF ARRAY(WATTS) 5220 CONDUCTOR(THWN-2, (904C))= 10 AWG RECIPIENTS ORGANIZATION, VOLTAGE OPERATING RANGE 8 - 4.8 V DC ADJ.ARRAY VMP ASHRAE 2%HIGH TEMP. 350 350 EGC CONDUCTOR RATING= 60 A EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE MAXIMUM CONT. INPUT CURRENT ISC 10 A DC CONDUIT FILL DERATE= 0.8 EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF MAXIMUM OUTPUT VOLTAGE 60 V DC AMB.TEMP.AMP.CORRECTION= 0.76 BLUERAVENSOLAR LLC. MAXIMUM OUTPUT CURRENT 15 ADC DC DISCONNECT CALCS AT OPTIMIZER: ADJUSTED AMP_= 36_48 > 18.75 MAX ALLOWED SYSTEM VOLTAGE VOC 1 V DC MAX SYSTEM VOC @ ASHRAE LOW TEMP_ I JUNCTION BOX TO MAX SHORT CIRCUIT CURRRENT ISC= 15.00 A DC W W dam' c Q c0 71- CEC WEIGHTED EFFICIENCY 98.8 % VOLTAGE RATED MAX_POWER(VMP) 350 350 INVERTER INPUT MAX.CURRENT(ISC X1.25)= 18.75 A DC 0 Z 0 - MAIC SHORT CIRCUIT CURRENT(ISC) 15 15 CONDUCTOR(II-MN-2,(90'C)= 10 AWG Z CL 06 0 0 ti INVERTER SPECIFICATIONS SolarEdge S -US CURRENT @ MAX POWER POINT(IMP) 7.46 7.46 CONDUCTOR RATING= 40 A < 0 I CL z M NUMBER OF M`PPTS 2 CONDUIT FILL DERATE= 0.8 2 H Z W OO MAXIMUM INPUT VOLTAGE ,_«1 V DC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL AMB.TEMP.AMP.CORRECTION= 0.76 U 0 c' 0 < MAXIMUM INPUT SHORT CIRCUIT CURRENT(ISC) 45 ADC AC OUTPUT CURRENT 21 A AC ADJUSTED AMP_= 24.32 > 1875 UJ °U Cr W MAXIMUM INPUT CURRENT 153 ADC NOMINAL AC VOLTAGE 240 V AC INVERTER OUTPUT INVERTER RATED AMPS= 21 A AC 0 D MAXIMUM USABLE DC INPUT POWER 6754 W PHOTOVOLTAIC DC DISCONNECT OUTPUT LABEL TO OCPD MAX_CURRENT(RATED AMPS X1.25)= 2625 A AC J MAXIMUM OUTPUT CURRENT 21 A AC MAXIMUM SYSTEM VOLTAGE(VOC) I V DC CONDUCTOR(THWN-2,(904C))= 10 AWG AC OVERCURR.ENT PROTECTION 30 A MAXIMUM POWER POINT VOLTAGE(VMP) 350 V DC CONDUCTOR RATING= 40 A MAXIMUM OUTPUT POWER 5450 W SHORT-CIRCUIT CURRENT(ISC) 30 A DC CONDUIT FILL DERATE= 1 CEC WEIGHTED EFFICIENCY 98 % RATED MAX POWER POINT CURRENT(IMP) 1491 A DC AMB.TEMP.AMP.CORRECTION= 036 ADJUSTED AMP_= 38.4 > 26?5 a 0 0 J C O ZN co GROUNDING NOTES 9. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR 5. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90'C RATED,WET AND UV N 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND STRANDED,AND BARE WHEN EXPOSED. RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE Q [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED. PER NEC, -(7)10. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC USED TO PROTECT WIRE FROM SHARP EDGES 2 (I) GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG 6 PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 0 a 2 (.) BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, SHALL BE USED WHEN EXPOSED TO DAMAGE). INSULATED,90°C RATED,WET AND UV RESISTANT,RATED FOR 600V (] ? N ILI2 a OR INADEQUATE.OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL 11. GROUNDING AND BONDING CONDUCTORS, IF INSULATED,SHALL BE COLOR 7.4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER z (0 0 GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE - N ›- CONSISTING CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. 12. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF MEANS W 2. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND _CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 8. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION - O (13 0 N NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING13. AC SYSTEM GEC SIZED ACCORDING TO[NEC 690.47].[NEC TABLE 250.66], DC 9. VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 1%FOR AC CIRCUITS i= 0 ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. 'SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#6AWG WHEN 10. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS DRAWING BY 3. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. FOLLOWS: DC POSITIVE-RED(OR MARKED RED), DC NEGATIVE-GREY(OR MARKED GREY) Carson Hawkes 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC 14. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, 11. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: 690.46]. EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 4. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC12. AC CONDUCTORS>4AWG COLOR CODED OR MARKED: DATE ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. October 28, 2016 690.42]. WIRING&CONDUIT NOTES PHASE A OR L1-BLACK, PHASE B OR L2-RED,PHASE C OR L3-BLUE, NEUTRAL-WHITE/GRAY 5. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT 1. ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTORAPPROVED FOR THE SITE APPLICATIONS BE USED INSIDE PROJECT NUMBER TO ANOTHER MODULE. 2. ALL PV CABLES AND HOMERUN WIRES BE#10AWG'USE-2, PV WIRE,OR '"USE-2 IS AVAILABLE AS UV WHITE 25233480 6. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS PROPRIETARY SOLAR CABLING SPECIFIED BY MFR,OR EQUIVALENT;ROUTED TO 13. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL BE IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. SOURCE CIRCUIT COMBINER BOXES AS REQUIRED EITHER EMT, FMC,OR MC CABLE COMPLYING WITH NEC 690.31, NEC 250.118(10)AND SHEET NAME 7. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH 3. ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC DISCONNECTING MEANS SHALL COMPLY WITH 690.13(B)AND(C)AND 690.15(A)AND(B). ELEC. CALCS. AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 690.8]FOR MULTIPLE CONDUCTORS CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 10"BELOW ROOF SURFACE. GROUNDING LUGS. 4. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE PAGE NUMBER REVISION 8. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND DERATED ACCORDING TO[NEC TABLE 310.15(B)(2)(a), NEC TABLE 310.15(B)(3)(a), PV6 0 GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. &NEC 310 15(B)(3)(c)] WARNINGLABEL 1 LABEL 8 I AT EACH JUNCTION BOX, COMBINER BOX, PHOTOVOLTAIC AT EACH AC DISCONNECTING ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS DISCONNECT AND DEVICE WHERE ENERGIZED MEANS BLUE RAVEN PHOTOVOLTAIC SYSTEM ARE UNGROUNDED UNGROUNDED CONDUCTORS MAY BE EXPOSED AC DISCONNECT [NEC 690.13(B)] ,_ AND MAY BE ENERGIZED. DURING SERVICE[NEC. 690.35(F)] 1220 S.630E STE.430 AMERICAN FORK.UT 84003 LABEL 2 LABEL 9 WARNING AT EACH DISCONNECTING MEANS FOR AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WWW.BLUERAV 800-377-4480 -4480 R.COM ELECTRIC SHOCK HAZARD PHOTOVOLTAIC EQUIPMENT[NEC 690.17(E)] �nrARNi'I�G. PHOTOVOLTAICWIRING METHODS; SPACED AT MAXIMUM 10FT SECTION OR DO NOT TOUCH TERMINALS -THE INFORMATION TERMINALS ON BOTH LINE AND LOAD SIDES: POWER SOURCE WHERE SEPARATED BY ENCLOSURES,WALLS, CONFIDENTIALHEREIN THEED INFORMAL TION MAY BE ENERGIZED IN THE OPEN POSITION E PARTITIONS, CEILINGS, OR FLOORS [NEC 690.31(G)(3)] USED FOR THE BENEFIT OF ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN LABEL 3 ., PART TO OTHERS OUTSIDE MAX.POWER POINT CURRENT(IMP). EMI DIRECTORY PLAQUE RECIPIENTS ORGANIZATION, AT EACH DC DISCONNECTING MEANS [NECNEG 690.53] EXCEPT IN CONNEC TION WITH THE MAX,POWER POINT VOLTAGE(VMP)_ ®' INTERACTIVE PHOTOVOLTAIC SYSTEM PERMANENT PLAQUE OR DIRECTORY PROVIDING THE SALE AND USE OF THE RESPECTIVE LOCATION OF THE SERVICE DISCONNECTING MEANS EQUIPMENT,WITHOUT THE MAX.SYSTEM VOLTAGE(NockIIIII CONNECTED LOCATION PERMISSION OF PHOTOVOLTAIC SYSTEM DISCONNECT AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING BLUERAVENSOLAR LLC. SHORT-CIRCUIT CURRENT(ISC)W 11111 LOCATED AT SIDE OF HOUSE MEANS IF NOT IN THE SAME LOCATION [NEC 690.56(B)] f1o LLlw 'ch O Q 4 LABEL 4 � CC00 PHOTOVOLTAIC LABEL 10 Z rn i.,....AC DISCONNECT AT POINT OF INTERCONNECTION, MARKED AT WARNING PLACED ADJACENT TO THE BACK-FED BREAKER FROM Q O l' CC Z c'? mom DISCONNECTING MEANS [NEC 690.54] INVERTER OUTPUT CONNECTION THE INVERTER IF TIE IN CONSISTS OF LOAD SIDE 2 F— Lo H LU o MAX.AC OPERATING CURRENT; MO DO NOT RELOCATE THIS H cO z OVERCURR€NT DEVICE CONNECTION TO BUSBAR. [NEC 705.12(D){2)(3)(3)] U O 0 < co NOMINAL AC OPERATING VOLTAGE wV 0 -, co w 0 i _1 LABEL 5 w m WARNING AT POINT OF INTERCONNECTION; LABEL,SUCH AS LABEL 5 OR LABEL 6 MUST IDENTIFY PHOTOVOLTAIC DUEL POWER SOURCES. SYSTEM SECOND SOURCE IS PV SYSTEM [NEC 705.12(D)(3)] a. LABEL 6 ✓ • °o PHOTOVOLTAICAT EACH DC DISCONNECTING MEANS J [NEC 690.13(B)] o DC DISCONNECT ._ -0 = �, 4. 0 CON- N a < �aii E5 LABELING NOTES: MAIN SERVICE PANEL w O N 0 U-1 UQ 1. LABELING REQUIREMENTS BASED ON THE 2014 NATIONAL ELECTRIC CODE, U- o O 1 j INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD 19010.145,ANSI Z535. Z (I) NEW PV SUBPANEL _ 2. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING Ors?.a.0r (IF O N ( INVERTER(S) w 13 JURISDICTION. EXISTING SUB PANEL USED AND F- N , t (� N 3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT (IF WHERE POINT OF COMBINING PV 0 o O INTERCONNECTION SOURCE CIRCUITS IN INVOLVED. IS MADE) AC DISCONNECT NEW LOAD CENTER) 4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 318",WHITE ON RED 0 o O DRAWING BY BACKGROUND: REFLECTIVE,AND PERMANENTLY AFFIXED[IFC 605.11.1.11 0 0 0 O 0 0 0 Carson Hawkes O 0 O DATE October 28, 2016 Ac JUNCTION BOX 0 • :I OR COMBINER BOX DC PROJECT NUMBER Og ° 0 25233480 0 O SHEET NAME ° ° 0 0 LABELS INTEGRATED DC DISCONNECT PAGE NUMBER REVISION PV8 0