Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (99)
ECEIV El) Printed Date: 11/3/2016 LGREENHECK Job: 7-11 #25562 Tigard OR Building Value inAir. ��� 2016 Mark: BRD for Roof Cap Model: BR-10 4.375 tIcy 0 .� GARD gill) IL' g Horizontal Mount Exhaust Damper b Application & Design 1 The BR-10 is an eccentrically pivoted backdraft damper for low velocity applications with no flanges.This model is a horizontally mounted damper and designed to allow vertical airflow up and prevent reverse airflow.To increase sensitivity and reduce blade mounted counterbalance,the blade skin is formed aluminum.On-blade counterweights are provided to fine tune start-to-open and full open blade operation.Ball bearings minimize friction. Recommended Applications: •Gravity hood intake and exhaust � �.( •Stairwell pressurization ••DRoom pressurization `j. • uctwork outlets RATINGS Back Pressure:2 in.wg w H Start-to-open Pressure:0.05 in.wg Velocity: /min Temmperature:ure: 180.0 F Installation instructions available at www.greenheck.com. Notes: All dimensions shown are in units of inches. W&H furnished approximately 0.25 in.undersized and only refer to damper dimensions(sleeve thickness is not included). W&H furnished approximately 0.25 in.undersized. Installation instructions available at www.greenheck.com. CONSTRUCTION FEATURES Frame Material: Galvanized Axle Bearings: Galvanized Ball Frame Thickness(ga): 16 Start Open Pr.(in.wg): 0.05 Blade Seal: TPE Sizing: Nominal • Axle Material: Plated Steel ID# Tag Qty W(in.) H(in.) Sections Sections Ship—S Wide High ec. 2-1 2 42.000 42.000 1 1 2 CITY OF TIGARD . REVIEWED FOR CODE COMPLIANCE Approved: I OTC: [ Permit#: ,�,(P(7, A 4Idress: #: .iia` Date: C( �(al OFFICE COPY Generated by:jhill@bartosindustries.com CAPS 4.21F18nles\Chad\7-11\Vixxo-FM Facility Maintenance Projects\Jobs\CRL160641-54 7-11 #25562 Tigard OR\7-11#25562 Tigard OR.gfcpage 2 of 3 I - LGREENHECK Printed Date: 11/3/2016 Job: 7-11 #25562 Tigard OR Building Value in Air. Mark: GRSR 42 Roof Cap Model: GRSR Sizes 8-24 B 11 ,i GGRSR Spun Aluminum Gravity Relief 1 1 STANDARD CONSTRUCTION FEATURES Dia. •Aluminum housing. •Aluminum curb cap with prepunched mounting holes. • A(Sq.) Recommended roof opening dimension is at least 2.5 in.larger than the Sizes 30-48 damper size. iiiiiii B C r' , D SELECTED OPTIONS&ACCESSORIES 75 Galvanized Birdscreen-0.5 in.Mesh Type - Dia. - I 4 Aluminum Housing A(sq.) Curb GPI-G12,Tray NOTE:All dimensions shown are in units of inches DIMENSIONS Opt. Opt. Unit ID# Tag Qty Model A sq. B on.) C(in.) D(in.) Dia. DamperhDamper Weigh Size (in. Length t(lb) (in.) (in.) 1-1 2 42 52 65.19 24.25 6.25 42.5 42 42 60 PERFORMANCE Model Volume Throat—V Throat ID# Tag qty Size (CFM) SP(in.wg) elocity— Area(ft2) (ft/min) 1-1 2 42 0 0 0 0 Generated by:jhill@bartosindustries.com CAPS 4.21Rgles\Chad\7-11\Vixxo-FM Facility Maintenance Projects\Jobs\CRL160641-54 7-11 #25562 Tigard OR\7-11 #25562 Tigard OR.gfcpage 3 of 3 / /GREENHECK Model BR-10 Series Barometric Relief Dampers Application Horizontal Mount - Vertical Airflow Up The BR-10 series is an eccentrically pivoted backdraft damper for low velocity systems. BR-10 series is a horizontally mounted damper and designed to allow t vertical airflow up and prevent reverse airflow.The blade `-. is formed aluminum which increases sensitivity and reduces blade mounted counterbalance weights. On-blade ��, counterweights are provided to fine tune start-to-open and �� , ,l full open blade operation. Ball bearings minimize friction. ��� Recommended Applications � �. • Gravity hood intake and exhaust �� • Stairwell pressurization W* ' H* • Room pressurization • Ductwork outlets Poor Applications • Propeller fan outlets(high velocity) •w&H dimensions furnished approximately 1/4 in.(6mm)undersize. • Centrifugal fan outlets(high velocity) • Building pressurization (sensitive to wind) • Pressure relief exceeding 0.13 in. wg(0.032 kPa) 5" I } a MAX 3/3 in. } I BR-10 Ratings iG 6 6i t 6' No Flange Back Pressure: 2.0 in. wg (0.5 kPa) o a Start-to-Open Pressure: 0.05 in. wg (.01 kPa) 1 in.nave Velocity: 2000 fpm (10.2 m/s) Temperature: 180°F(82°C) Construction Standard Optional t t BR-11 Frame Material Galvanized Steel 304SS,Aluminumtri, - Flange on Frame Thickness 16 ga. - o 0 0 6 Discharge (1.5mm) f 1.5 in. No Flange - (BR-10) Frame Type Flange on Discharge t t t BR-12 (BR-11) Flange on Intake - 6 6 6 Flange on 1 Intake (BR-12) v v —,— Fes--1.5 in. Blade Material Aluminum - Blade Seal TPE None Airflow Blade Thickness 0.063 in. - (1.6mm) Size Limitations Axle 3/8 in.(9.5mm)sq. 304SS Galvanized Steel Maximum Size Minimum Axle Bearings Galvanized Steel Press Fit Acetal w/SS Ball W x H Size Single Multiple Linkage Material Galvanized Steel - Section Sections Jamb Seal None EPDM Inches 8 x 6 48 x 74 96 x 148 Counterbalance Blade mounted with mm 203 x 152 1220 x 1880 2438 x 3759 adjustable weights Paint Finishes None Baked Enamel, Feature Epoxy, Hi Pro Polyester, • Selectable start open from .05 to .13 in. wg Industrial Epoxy, (0.012 kPa-0.032 kPa). Kynar/Hylar(70%) Installation instructions available at www.greenheck.com. Performance Data BR-10 Series Performance data results from testing a 12 in. x 12 in. and 36 in. x 36 in. (305mm x 305mm and 914mm x 914mm) in accordance with AMCA Standard 500-D using Figure 5.3 (fully ducted), 5.2 (ducted exhausting into an open area), and 5.5 (plenum mounted).All data has been corrected to represent standard air density at 0.075 lb/ft'(1.201 kg/m3). Damper Size Damper Size 12 in. x 12 in. 36 in.x 36 in. (305mm x 305mm) (914mm x 914mm) 2.0 2.0 5.5 5.5 1.0 1.0 .9 .9 .8 .8 7 5.2 5.2 7 .6 .6 .5 .5 5.3 5.3 3 4 6 .4 •G .3 II 3 CO N 2 .2 N N .09 .09 .08 .08 .07 .07 .06 .06 .05 .05 .04 .04 .03 .03 100 200 300 400 500 600 800 1000 2000 3000 100 200 300 400 500 600 800 1000 2000 3000 700 900 700 900 Velocity Velocity (fpm) (fpm) Specifications Barometric backdraft dampers meeting the following TPE blade seals; and internal plated steel blade-to-blade specifications shall be furnished and installed where shown linkage with blade mounted counterbalance weights. on plans and/or as described in schedules. Damper manufacturer's printed application and Dampers shall consist of: 16 ga. (1.5mm) insert mount performance data including pressure, velocity, and galvanized steel hat channel frame with 5 in. (127mm) temperature limitations shall be submitted for approval depth; blades from 0.063 in. (1.6mm)thick formed showing damper suitable for pressures to 2 in. wg (0.5 aluminum, eccentrically pivoted; 3/8 in. (9.5mm)square kPa), velocities to 2000 fpm (10.2 m/s, and temperatures plated steel axles with galvanized steel press-fit ball to 180°F(82°C).Testing and ratings to be in accordance bearings; damper shall be equipped with pressure activated with AMCA Standard 500-D. Basis of design is Greenheck model BR-10. IMGREENHECK Copyright©2016 Greenheck Corporation BR-10 Series Rev.4 February 2016 P.O.Box 410•Schofield,WI 54476-0410•715.359.6171•greenheck.com Pd GREENHECK BR series Counterweight Adjustments Part number 469420 Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. Illi RECEIVING AND HANDLING Upon receiving dampers, check for both obvious Illi and hidden damage. If damage is found, record all �, necessary information on the bill of lading and file t. a claim with the final carrier. Check to be sure that Ih / all parts of the shipment, including accessories, Ill', `I_t. are accounted for. Dampers must be kept dry and clean. Indoor I storage and protection from dirt, dust and the . / weather is highly recommended. Do not store at temperatures in excess of 100°F(37°C). 4, . -' -,,, 1 c, ��� �, SAFETY WARNING: �� Improper installation, adjustment, alteration, `�I service or maintenance can cause property damage, injury or death. Read the installation, operating, and maintenance instructions ,� thoroughly before installing or servicing this equipment. Due to continuing research, Greenheck reserves the right to change specifications without notice. Pre-Installation Guidelines The basic intent of a proper installation is to secure the damper into the opening in such a manner as to prevent distortion and disruption of damper operation.The following items will aid in completing the damper installation in a timely and effective manner. 1) Check the schedules for proper damper locations within the building.Visually inspect the ii A spreeeerear damper for damage. All ll MAI.IMIA PttacM1meMS 2) Lift or handle damper using sleeve or frame. Do not lift damper using blades or linkage. 1111mallmminns When handling multiple sections assemblies, use sufficient support to evenly lift at each �l==_ section mullion(see Figure 1). Do not drag,step on,apply excessive bending,twisting, or M1=== racking. -=_- =�. MWti section Campers 3) Do not install screws in damper frame that will interfere with damper blades and prevent Figure 1-supports for lifting a them from opening and/or closing. multi-section damper 4) Damper must be installed into duct or opening square and free of twist or other misalignment. Damper must not be squeezed or stretched into duct or opening.Out of square, racked,twisted or misaligned installations can cause excessive leakage and/or prevent free operation. 5) Damper must be kept clean,dry and protected from dirt,dust and other foreign materials prior to and after installation. Examples of such foreign materials include but are not limited to: a) Drywall/mortar dust b) Firesafing materials c) Wall texture d) Paint overspray Pre-Installation Guidelines continued.... 6) Damper should be sufficiently covered as to prevent overspray if wall texturing or spray painting will be performed within 5 feet(1.50m)of the damper. 7) ACCESS:Suitable access must be provided for damper inspection and servicing.Where it is not possible to achieve sufficient size access, it will be necessary to install a removable section of duct. Counterweight Adjustment Procedure for BR Models Dampers are shipped from the factory with frame flange location and flow direction as ordered.Location and size of both counterbalances(blade edge,adjustable blade weights)are dependent upon flow direction and damper size.The damper must be mounted square and plumb and must operate freely before any weight adjustments are performed.Contact Greenheck for required modifications to change flow directions. The following instructions should be followed when attempting to adjust counterweights on the BR series damper. Figure 1,1A,& 1B shows the typical location of the adjustable counterweight assembly.Depending on the size of the damper and specified start open pressure,the damper may have more than one counterweight assembly. Adjustable Counterweight Assembly `►/ III^ Adjustable Counterweight Figure 1 Assembly BR-1 x series r �r► NOWN � 3 IIP ° t Figure lA 9 s BR-3x series - 4 , Figure 1B Adjustable BR-4x series Counterweight Assembly Counterbalance Adjustment for BR-1X Series: Horizontal mount - Vertical Up Airflow Figures 2&3 show the components of a typical adjustable counterweight assembly. BR-1X series damper with a short height may have a different style blade and a trimmed mounting bracket.The adjustment procedure is the same for both styles of blades. � The blade edge counterweight(Figure 3)is factory set and not intended for field adjustment.For vertical up airflow,all adjustments should be made in the adjustable counterweight assembly. When adjusting the counterbalance weights,you will need to adjust the full open pressure and start open pressure.Both steps will need to be done. Adjusting Full Open Pressure and Closing Force Figure 2 Adjustable counterweight assembly Adjusting the closing force will also affect the full open pressure. Figure 3 shows the blade in the full open position.Additional weights can be added to increase the closing force.Removal or trimming of weights will reduce the closing force.After adjustment,verify blades close under no airflow from the full open position.Increase the closing force if the blades fail to close. • Counterbalance Adjustment for BR-1X Series: Horizontal mount - Vertical Up Airflow cont Damper Blade Adjusting Start Open Pressure y / Counterweight Adjustment When the blades are in the closed position,the adjustable weights are used for the start open pressure Bracket Counterbalanced I of the damper.Sliding the weights toward the blade seal will increase the start open pressure and sliding Weights\ the weights toward the blade edge counterweight will decrease pressure(Figure 4). / y mil If sliding the weights to the furthest left position(toward the blade seal)does not provide a high enough start open pressure,additional weights can be added.In this case,the closing force will also increase. �JI Blade Edge Counterweight m m , Figure 3-Adjustable Increases Start Decreases Start counterweight assembly Open Pressure Open Pressure detail Figure 4:Counterweight adjustment for start open pressure.Blade is shown in full close position Dampers are factory adjusted to the start open pressure,based upon your order, for the specified flow direction.Typically,a minimum of one weight plate will be used to keep blades closed,although only the mounting bracket may be sufficient for small damper sizes. Consult factory for plate quantity and sizing if an elevated start open pressure is required. Final Adjustment Check After adjusting the counterweights,verify that no interference occurs between the counterweights and the adjacent blades.If any interference,adjust counterweights.Also verify that the damper blades close under no airflow from the full open,1/2 open,and 1/4 open positions.If blades do not close,adjust weights as required. Counterbalance Adjustment for BR-3X Series: Vertical mount - Horizontal Airflow Blade Edge `E--Counterweight Figure 5 details the components of a typical adjustable counterweight assembly.Dampers with a short height may have a different style blade and a trimmed mounting bracket.The adjustment procedure is the same for both styles of blades. ', 'lig The blade edge counterweight(Figure 5)is factory set and not intended for field adjustment.For Counterbalance': Weights horizontal airflow,all adjustments should be made in the adjustable counterweight assembly. When adjustingthe counterbalance weights,you will need to the full openpressure and Counterweigl 9 adjustp Adjustment bracket start open pressure. Both steps will need to be done. DamperBlade Adjusting Start Open Pressure Figure 5-Adjustable counterweight assembly detail When the blades are in the closed position(Figure 5),the adjustable weight are used for the start open pressure of the damper.Additional weights can be added to increase start open pressure and removal or trimming of weights will reduce start open pressure.After adjustment,verify blades close under no airflow from the 1/4 open position.If the blades fail to close,additional weight is required. Adjusting Full Open Pressure and Closing Force Adjusting the closing force will also affect the full open pressure.Figure 6 shows the blade in the full open position.If blades hang open or more closing force is desired,slide weights toward the bottom of the bracket(Figure 6). If the blades close too fast or less closing force is desired,move weights toward the top of the bracket(Figure 6). eopecreases Closing a:: IClos,n9 . Fncreasesorce mm a� Bracket /W Figure 6:Counterweight adjustment in the full open position Counterbalance Adjustment for BR-3X Series: Vertical mount - Horizontal Airflow cont Dampers are factory adjusted to the start open pressure, based upon your order, for the specified flow direction.Typically,a minimum of one weight plate will be used to keep blades closed,although only the mounting bracket may be sufficient for small damper sizes. Consult factory for plate quantity and sizing if an elevated start open pressure is required. Final Adjustment Check After adjusting the counterweights,verify that no interference occurs between the counterweights and the adjacent blades.If any interference,adjust counterweights.Also verify that the damper blades close under no airflow from the full open,1/2 open,and 1/4 open positions.If blades do not close,adjust weights as required. Counterbalance Adjustment for BR-4X Series: Horizontal mount - Vertical Down Airflow Figure 7 details the components of a typical adjustable counterweight assembly.Dampers with Blade Edge a short height may have a different style blade and a trimmed mounting bracket.The adjustment Counterweight Counterweight Adjustment procedure is the same for both styles of blades. Bracket The blade edge counterweight(Figure 7)is factory set for the specified start open pressure. For vertical down airflow,minor adjustments can be made in the adjustable counterweight assembly. If the desired change is greater than the capability of the adjustable counterweight assembly,then changes to the blade edge weight would be required.Consult factory for assistance in adjusting blade edge weight. When adjusting the counterbalance weights,you will need to adjust the full open pressure and sit Counterbalance start open pressure. Both steps will need to be done. Weights Adjusting Full Open Pressure and Closing Force / Adjusting the closing force will also affect the full open pressure.Figure 7 shows the blade in Figure 7- Adjustable counterweight the full open position.Additional weights can be added to increase the closing force.Removal assembly detail or trimming of weights will reduce the closing force.After adjustment,verify blades close under no airflow from the full open position.Increase the closing force if the blades fail to close. Adjusting Start Open Pressure When the blades are in the closed position,the adjustable weights are used for the start open pressure of the damper.Sliding the weights toward the blade edge counterweight will increase the start open pressure and sliding the weights toward the blade seal will decrease pressure(Figure 8). MIN m m < I Increases Decreases Open Pressure Open Pressure Figure 8:Counterweight adjustment for start open pressure. Blade is shown in full close position. If sliding the weights to the furthest left position(toward the blade edge counterweight)does not provide a high enough start open pressure,additional weight to the blade edge counterweight would be required.Consult factory with desired start open pressure. Dampers are factory adjusted to the start open pressure, based upon your order, for the specified flow direction.Typically,a minimum of one weight plate will be used to keep blades closed,although only the mounting bracket may be sufficient for small damper sizes. Consult factory if an elevated start open pressure is required. Final Adjustment Check After adjusting the counterweights,verify that no interference occurs between the counterweights and the adjacent blades.If any interference,adjust counterweights.Also verify that the damper blades close under no airflow from the full open,1/2 open,and 1/4 open positions.If blades do not close,adjust weights as required. GREENHECK Copyright©2006 Greenheck Fan Corporation #469420 BR series IOM Rev 1 August 2006 P.O.Box 410•Schofield,WI 54476-0410•715 359 6171•greenheck.com GREENHECKPart #473219 GRS Hardware Kit Building Value in Air. Assembly Instructions Please read these instructions carefully before attempting to assemble the product described.Protect yourself and others by observing all safety information.Failure to comply with instructions could result in personal injury and/or property damage! Hardware Kit (1) Hinge Assembly Right Part No. 822023 (1) Hinge Assembly Left Part No. 822024 (4) 1/4-20 Weld Bolt Part No. 415943 (4) 1/4-20 Nut Part No. 415455C:°I) SEE DETAIL A 10 •1414.1. 1/4-20 x 3/4 WELD BOLT HINGEASSEMBLY RIGHT7 GRS UNIT 1/4-20 NUT •.JI ; 0 051 •I DETAIL A • Phone:(715)359-6171 •Fax:(715)355-2399•E-mail:gfcinfo@greenheck.com•Website:www.greenheck.com 473219•GRS Hardware Kit,Rev.1,December 2009 Copyright©2009 Greenheok Fan Corp.