Plans (3) w 1 MILBRANDT ARCHITECTS Bulletin 25 Central Way, Suite 210 • Kirkland, WA 98033 Tel: (425) 454-7130 • Fax: (425) 646-0945 Bulletin#: MA-12 Date: 8-17-2016 ATTACHMENTS: MA-12 Job Name: RIVER TERRACE Job No: 15-03 This bulletin is in response to a request from the City of Tigard regarding a 1/Z"P.T. plywood spacer strip being installed behind the deck ledger as shown on the attached MA-12 detail. The attached MA-12 detail is approved by Milbrandt Architects to be used for the deck ledger installation on the River Terrace project. CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved:-'''N OTC: Permit #: rns-1-An ) C -00d6--9 Address: is- - sw rte,-r,cs sr Suite#: By: Date: q- I- J c OFFICE COPY Distribution: From: David Burnett Polygon Northwest Attn: Chris Walther Phone: (360)695-7700 REVISION BUILDING PAPER * PRE—FLASHING, EXTEND 6" ABOVE LEDGER, MIN. I METAL Z—FLASHING TYPE B SEE DETAIL 19/15 SPACED DECKING 2 3 l i �' .4 v .r-----1 I L1TT�71-i�rr ��I — liP.T. 2x JOISTS I II SEE STRUC. FOR CONNECTION DETAILS a i P.T. 2x LEDGER P.1.° PLYWOOD FUR STRIPS, Y2" x 1Y2"-2" AT EVERY LAG. TYPE A FLASHING INSEE DETAIL 19/15 PRE—FLASHING, EXTEND 2" BELOW LEDGER, MIN. SIDING BUILDING PAPER OR PRE—FLASHING; EXTEND TO ABOVE DECK—TO—WALL FLASHING DECK TO WALL FLASHING ; SPACED DECKING } 1-1/2" = 1'-o" S ECTIF N R317.1.1.1 Field treatment/ Field-cut ends, notches and drilled holes of preservative-treated wood shall be treated in the field in accordance with AWPA M4 PROJECT NAME: RIVER TERRACE ARCH. JOB NO.: 1503 BULLETIN E IN DATE 08-16-16 SCALE: 1 1/2" = 1'-0" PAGE: PREPARED BY: DAVID BURNETT REF. SHEETS: DETAILS MA-12 This bulletin is a stand-alone document. Referenced sheets posted at online plan center have NOT been updated typically. C T ENGINEERING INC 180 Nickerson St. Suite 302 Seattle,WA 98109 (206)2854512(V) (206)285-0618(F) asolomon@ctengineering.com BULLETIN Date: August 17,2016 Number:CT-11 Project#: 15238 Project Name: River Terrace Attached: None Subject: Deck Connection Detail(Spaced Decking) Drawings Affected: Description/Action: This bulletin provides response to RFI, design clarifications and/or variation requests for the 'River Terrace' project located in Tigard, Oregon. Based on our review of Bulletin MA-12 (Deck to Wall Flashing—Spaced Decking), this is an acceptable deck connection detail provided the fasteners attaching the ledger to the structure have the required penetration to the rim/blocking per the structural deck details. 0,0 PRO GiNeyf 116 gREGOlk •c eS T. Gk\F 08/17/2016 CALL WITH ANY QUESTIONS Issued by: Arnold R. Solomon Date: Aug. 17,2016 Distribution: Contact Information: Chris Walther Polygon Northwest Company Angela Graiewski Polygon Northwest Company David Burnett Milbrandt Architects R:\15238 River Terrace\Bulletins\15238_2016.08.17 CT11_Deck Connection Detail(Spaced Decking).doc Structural Engineers FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT 7i = Transmittal Letter i 1 GA R n 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 •www.tigard-or.gov TO: Tom H. DATE RECEIVED: DEPT: BUILDING DIVISION C :¢ i '' v�s AUG 222016 FROM: Angela Grajewski YY COMPANY: Polygon Northwest 3i,i t i t a, ' r. PHONE: 971-212-2144 RE: (c7 ITL Sv\C 11 nes C-k- t 0 t 52- MST201(Q -00;51 (Site Address) (Permit Number) Polygon at Bull Mountain (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: so- '' -aa :A to , 1 :7rtai. 0 Additional set(s) of plans. 0 Revisions: 0 Cross section(s) and details. 0 Wall bracing and/or lateral analysis. 0 Floor/roof framing. 0 Basement and retaining walls. 0 Beam calculations. 0 Engineer's calculations. 3 Other(explain): Additional deck details requested by inspector REMARKS: Routed to Permit Technician: Date: • - _ ) — / ( Initials: ,MIIII Fees Due: IN Yes ❑No Fee Descri.tion: Amount Due: , •.,-7:' 0• S -v PIA Rev; 13111=1110.111 4 � � $ ` f rH x LI_ _,::__2:,..2 '"swat , Special Instructions: Re.Tint Permit .er PE : ❑ Yes [V No ❑ Done A•plicant Notified:gNN/E Date: Inti. I:\Building\Forms\TransmittalLetter-Revisions.doc 05/25/2012 /-IC 1-CS c-t