Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
r -11";261 -6t-7/7S _ ,i� 132. /c ' t&C-'CS t5f 7 tqCf3 SEP 2 9 CO1 Worldwide www.tyco-fire.com Fire Protection Products ��7y1_,�' y y ,:0),.1',, , Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General when exposed to corrosive atmo- spheres. Although corrosion-resistant Description coated sprinklers have passed the standard corrosion tests of the appli- The TYCO Series TY-FRB, 2.8, 4.2, cable approval agencies,the testing is , 5.6,and 8.0 K-factor,Upright,Pendent, not representative of all possible cor- and Recessed Pendent Sprinklers rosive atmospheres. Consequently, described in this data sheet are quick it is recommended that the end user be consulted with respect to the suit- 'z response, standard coverage, deco- z= rative 3 mm glass bulb-type spray ability of these coatings for any given !' sprinklers designed for use in light or corrosive environment. The effects of ordinary hazard,commercial occupan- ambient temperature,concentration of " chemicals and gas/chemical velocity, cies such as banks, hotels, and shop- should be consiered, as a minimum, ping malls. along with the corrosive nature of the "" The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where exposed. applicable,is intended for use in areas An intermediate level of the Series with a finished ceiling. This recessed TY-FRB Pendent Sprinklers is detailed polflowing:Wentt sprinkler uses one of the in Technical Data Sheet TFP356, and g Sprinkler Guards are detailed in Tech- • A two-piece Style 10(1/2 inch NPT) nical Data Sheet TFP780. {' or Style 40(3/4 inch NPT)Recessed Escutcheon with 1/2 inch (12,7 mm) At of recessed adjustment or up to 3/4 NOTICE } inch (19,1 mm) of total adjustment The Series TY-FRB, 2.8, 4.2, 5.6, ` ,) from the flush pendent position,or a and 8.0 K-factor, Upright, Pendent, ! and Recessed Pendent Sprinklers • A two-piece Style 20(1/2 inch NPT) described herein must be installed or Style 30(3/4 inch NPT)Recessed y and maintained in compliance with � ,11 Escutcheon with 1/4 inch (6,4 mm) this document and with the applica- 4 ', of recessed adjustment or up to 1/2 ble standards of the National Fire Pro- inch (12,7 mm) of total adjustment tection Association, in addition to the from the flush pendent position. standards of any authorities having The adjustment provided by the jurisdiction.Failure to do so may impair Recessed Escutcheon reduces the the performance of these devices. Sprinkler accuracy to which the fixed pipe drops The owner is responsible for maintain- Identification to the sprinklers must be cut. ing their fire protection system and Corrosion-resistant coatings, where devices in proper operating condition. Number (SIN) applicable,are utilized to extend the life The installing contractor or sprinkler of copper alloy sprinklers beyond that manufacturer should be contacted with TY1131 -Upright 2.8K,1/2"NPT which would otherwise be obtained any questions. TY1231 -Pendent 2.8K,1/2"NPT TY2131 -Upright 4.2K,1/2"NPT (`7- TY2231 -Pendent 4.2K,1/2"NPT IMPORTANT TY3131 -Upright 5.6K,1/2"NPT Always refer to Technical Data OFFICE COPY TY3231 -Pendent 5.6K,1/2"NPT Sheet TFP700 for the "INSTALLER TY4131 -Upright 8.0K,3/4"NPT WARNING"that provides cautions TY4231 -Pendent 8.0K,3/4"NPT with respect to handling and instal- TY4831 -Upright 8.0K,1/2"NPT lation of sprinkler systems and corn- TY4931 -Pendent 8.0K,1/2"NPT ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 NOVEMBER 2015 TFP171 1 J TFP171 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing 7 ireMMEMMIN oy r$ 1 7/16 ■1:�_ 3 1 (11,1 mm) I Iit A 4 NOMINAL 21/4"1 / amm- ��— r 2 MAKE IN �'� I — (57,2 mm) r�r 2 3/16" 4 (55,6 mm) i (390 ,7 mm) . 1 r. 5 'i 1/2"NPT** f WRENCH STYLE 10 or 20 If 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7/,6" i■fes 1 (11,1 mm) � ��— i 2 NOMINAMAKE-INL dol i (5236/1m%) 5 6/m) 4 ii. 4� 2-3/16" 1-1/2" �l 1 (55,6 mm) i ii (38,1 mm) i'7 5 1 — 1 le 0 * 1/\NPT** t WRENCH -_-�___ STYLE 10 or 201--.--2-7/8" DIA. (73,0 mm) "fir.______.. 6 FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE 1 7/16" P Of (11,1 mm) / .._--- J' r ___ 04• i NOMINAL —d 1111. f 2-3/16" WII 1lAt6i:Al 2 MAKE IN I (55,6 mm) ____ ��� 4 1 (55 6/m) I t (38,11/2" mm) fes—5 6* 1/2"NPT** t WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING SURFACE 4 - Bulb 6 - Deflector* y, 1 i (110,7 M NAL I C %� 3 �.Eni-IniN) 2-5/16" � 2 `—� 1 (58,7 mm) A (57,2/mm) I 1-9/16" 4 -111 (39,7 mm) 3/4"NPT** WRENCH STYLE 30 or 40 % �— g* FLATS RECESSED 2 7/8"(73,0 mm)DIA. UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw �•""m _ 1 3 Sealing 6 Deflector Assembly 7/16" g 4 - Bulb (11,1 mm) 'r 2-1/4" �y NOMINAL (57,2 mm) I 2 MAKE-IN *Temperature rating is roil 2-3/16" 1-9/16" I 4 indicated on Deflector. (55 (39,7 mm) fc-�5 ** Pipe thread connections __� ._„ ��iW _ * Per ISO 7-1 can be 1/2"NPT** } 6 provided on special WRENCH request. UPRIGHT FLATS PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT e' WRENCH RECESS WRENCH RECESS (END"A"USED FORrr1 NPT MODELS) i WRENCH RECESS (END"B"USED FOR �...� 3/4"NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 FIGURE 7 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH 4 TFP171 Page 4 of 10 Do not attempt to compensate for Desi n insufficient adjustment in the Escutch- DataTechn�cal � eon Plate by under-or over-tightening Criteria the sprinkler.Re-adjust the position of the sprinkler fitting to suit. Approvals The TYCO Series TY-FRB, 2.8, 4.2, UL and C-UL Listed 5.6,and 8.0 K-factor,Upright,Pendent, Series TY-FRB Upright and Pendent FM,LPCB,and NYC Approved and Recessed Pendent Sprinklers are Sprinklers Refer to Table A and B for complete intended for fire protection systems The Series TY-FRB Pendent and approval information including corrosion- designed in accordance with the stan- Upright Sprinklers must be installed resistant status. dard installation rules recognized by in accordance with the following Maximum Working Pressure the applicable Listing or Approval instructions. Refer to Table C. agency (such as, UL Listing is based Step 1.Install Pendent sprinklers in the on the requirements of NFPA 13, and Step 1.t posin.Install upright hDischarge Coefficient FM Approval is based on the require- plerd in the upright position. sprin- K=2.8 gpm/psi' (40,3 Ipm/bars) ments of FM's Loss Prevention Data K=4.2 gom/psis(60.5 IDm/bar11 Sheets). Only the Style 10, 20, 30, or Step 2. With pipe-thread sealant K=5.6 gpm/psi' (80,6 Ipm/bars) 40 Recessed Escutcheon,as applica- applied to the pipe threads, hand- K=8.0 gpm/psii'2(115,2 Ipm/bar'6) ble,is to be used for recessed pendent tighten the sprinkler into the sprinkler installations. fitting. Temperature Rating Step 3. Tighten the sprinkler into the Refer to Table A and B. Installation sprinkler fitting using only the W-Type Finishes6 Sprinkler Wrench(Figure 6).With ref- Sprinkler:Refer to Table D. The TYCO Series TY-FRB,2.8,4.2,5.6, erence to Figures 1 through 5, apply and 8.0 K-factor,Upright,Pendent,and the W Type 6 Sprinkler Wrench to the Recessed Escutcheon:Signal or Pure Recessed Pendent Sprinklers must sprinkler wrench flats. Natural Btrrass BBlack,Chrome Plated,or be installed in accordance with this section. Series TY-FRB Recessed Pendent Physical CharacteristicsSprinklers Frame Bronze General Instructions The Series TY-FRB Recessed Pendent Button Brass/Copper Do not install any bulb-type sprinkler Sprinklers must be installed in accor- Sealing Assembly..Beryllium Nickel w/TEFLON if the bulb is cracked or there is a loss Bulb Glass of liquid from the bulb.With the sprin- dance with the following instructions. Compression Screw Bronze kler held horizontally,a small air bubble Step A.After installing the Style 10,20, Deflector Copper/Bronze Bushing(K=2.8) Bronze should be present.The diameter of the 30, or 40 Mounting Plate, as applica- air bubble is approximately 1/16 inch ble,over the sprinkler threads and with Operation (1,6 mm)for the 135°F(57°C)and 3/32 pipe-thread sealant applied to the pipe inch(2,4 mm)for the 286°F(141°C)tern- threads,hand-tighten the sprinkler into The glass bulb contains a fluid that perature ratings. the sprinkler fitting. expands when exposed to heat.When A leak-tight 1/2 inch NPT sprinkler Step B. Tighten the sprinkler into the the rated temperature is reached, the joint should be obtained by applying a sprinkler fitting using only the W-Type fluid expands sufficiently to shatter the mini mum to maximum torque of 7 to 7 Recessed Sprinkler Wrench (Figure glass bulb, allowing the sprinkler to 14 ft.-lbs.(9,5 to 19,0 Nm).A leak tight 7). With reference to Figures 1 to 4, activate and water to flow. 3/4 inch NPT sprinkler joint should be apply the W-Type 7 Recessed Sprinkler obtained with a torque of 10 to 20 ft.- Wrench to the sprinkler wrench flats. lbs. (13,4 to 26,8 Nm). Higher levels of Step C. After ceiling installation and torque can distort the sprinkler Inlet finishing, slide on the Style 10,20, 30, with consequent leakage or impairment or 40 Closure over the Series TY-FRB of the sprinkler. Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** FACTOR COLOR BRASS PLATED 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 UPRIGHT ) (TY1131) (200°F 93°C Green 286°F(141°C) Blue 135°F(57°C) Orange 2.8 RECESSED 1/2"NPT PENDENT 155°F(68°C) Red (TY1231)* 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 1,2,4 135°F(57°C) Orange RECESSED ) PENDENT (155°F 68°C Red (TY1231)** 175°F(79°C) Yellow Figure 9 200°F(93°C) Green 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY2231) and 175°F(79°C) Yellow UPRIGHT L, 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F(68°C) Red 1,2 „ (TY2231)* 175°F(79°C) Yellow Figure 10 200°F(93°C) Green 135°F(57°C) Orange RECESSED ) PENDENT (155°F 68°C Red (TY2231)** 175°F(79°C) Yellow Figure 11 200°F(93°C) Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed byUnderwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. P P 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS • TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** LEAD FACTOR COLOR BRASS PLATED COATED 135°F(57°C) Orange PENDENT (TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F(93°C) Green (TY3131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 5.6 PENDENT 175°F(79°C) Yellow 1,2,4,5 N/A 1/2"NPT (TY3231)* Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,4,5 N/A (TY3231)** Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT (TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F(93°C) Green (TY4131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 8.0 PENDENT 175°F(79°C) Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 14 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,5 N/A (TY4231)** Figure 15 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT 8.0 (TY4931) 155°F(68°C) Red 1/2"NPT and 175°F(79°C) Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F(93°C) Green (TY4831) 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH KTYPE NATURAL CHROME LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) ----->1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY2231) PENDENT(TY3231) and 5.6 UPRIGHT(TY3131) 250 PSI(17,2 BAR) 1/2"NPT OR 175 PSI(12,1 BAR) RECESSED (SEE NOTE 1) PENDENT(TY3231) PENDENT(TY4231) and 175 PSI 8.0 UPRIGHT(TY4131) (12,1 BAR) 3/4"NPT 175 PSI(12,1 BAR) - RECESSED PENDENT(TY4231) N/A 8.0 PENDENT(TY4931) 1/2"NPT and 175 PSI(12,1 BAR) 175 PSI UPRIGHT(TY4831) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval bythe City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and havenot operated,should be replaced Care must be exercised to avoid if they cannot be completely cleaned damage to the sprinklers -before, Maintenance by wiping the sprinkler with a cloth or during, and after installation. Sprin- by brushing it with a soft bristle brush. klers damaged by dropping, striking, The TYCO Series TY-FRB must be Care must be exercised to avoid wrench twist/slippage,or the like,must maintained and serviced in accordance damage to the sprinklers before, be replaced. Also, replace any sprin- with this section. during, and after installation. Sprin- kler that has a cracked bulb or that has Before closing a fire protection system klers damaged by dropping, striking, lost liquid from its bulb. (Ref. Installa- main control valve for maintenance wrench twist/slippage,or the like,must tion Section). work on the fire protection system be replaced. Also, replace any sprin- Initial and frequent visual inspections of that it controls, obtain permission to kler that has a cracked bulb or that has random samples are recommended for shut down the affected fire protection lost liquid from its bulb. (Ref. Installa- corrosion-resistant sprinklers to verify systems from the proper authorities tion Section.) the integrity of the corrosion-resistant and notify all personnel who may be The owner is responsible for the material of construction. Thereafter, affected by this action. inspection,testing,and maintenance of annual inspections per NFPA 25 should Absence of the outer piece of an their fire protection system and devices suffice. escutcheon, which is used to cover in compliance with this document, as Inspections of corrosion-resistant a clearance hole, can delay sprinkler well as with the applicable standards sprinklers are recommended at close operation in a fire situation. of the National Fire Protection Asso- range, instead of from the floor level ciaSprinklers which are found to be thet stionandards of any oA ther auin thorities ition to caner NFPA. Inspection e the close exact range leaking or exhibiting visible signs of having jurisdiction.Contact the install- can better determine the lointeg- corrosion must be replaced. in contractor or sprinkler manufac- rity ofhe condition andcorrosion-resistante smm teria, g p rity the material, Automatic sprinklers must never be turer regarding any questions. which can be affected by the corrosive painted, plated, coated, or other- Automatic sprinkler systems are rec- conditions present. wise altered after leaving the factory. ommended to be inspected, tested, Modified sprinklers must be replaced. and maintained by a qualified Inspec- Sprinklers that have been exposed to tion Service in accordance with local corrosive products of combustion,but requirements and/or national codes. f TFP171 Page 8 of 10 2-7/8"DIA. 2-7/8"DIA. _ (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2"(12,7 mm) 5/8±1/4" 1/2±1/8" (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) 2-1/4"DIA. r -1/457 2 mm) IA / FACE OF (57,2 mm) MOUNTING / FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) / (3,2 mm) izi ��`�JMOUNTING illmw \ %ii �� f SU ,�rMOUNTING �i I SURFACE i�/f•1�� CLOSURE SERIES 1-5/16"(33,3 mm) SERIES 1-5/16"(33,3 mm) CLOSURE TY-FRB 1-1/16"(27,0 mm) TY-FRB 13/16"(20,6 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. 2-7/8"DIA. 73,0 mm) (73,0 mm) 1/2"(12,7 mm) 5/8±1/4" ( 3/4"(19,1 mm) 1/2±1/8" 15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) ( 2-1/4"DIA. (57,2 mm) _y / FACE OF (57'2 mm) MOUNTING / FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING / I / 1/8" (3,12/Mm) (3,2 mm) ' �� �i 177 7/ Wil_ I,� I IX It_ �`�� 1 MOUNTING\ -27zi 1,,jr, SURFACE ,irMOUNTING . SURFACE .. _ .. 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE SERIES CLOSURE TY-FRB 1"(25,4 mm) TY-FRB 3/4"(19,1 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3M INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2"(12,7 1/2±1/8" mm) (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 2-1/4"DIA. 1/4"(6,4 mm) / FACE OF (57,2 mm) MOUNTING / FACE OF (57,2 mm) SPRINKLERPLATE SPRINKLER MOUNTING PLATE FITTINGFITTING / (3,2 m / 1/8" �11 7----- mm) z_i_ �1 'J (3,2P771mm) . llJ �. J. Illi.3 r'7/ i NMOUNTING , SURFACE SURFACE ,SPO .A,-_ CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3M INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. _ 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/211/8" (73,0 mm) 1/2"(12,7 mm) 15,9±6,4 mm) 1/4"(6,4 mm) 2 1/4" DIA. 1/4"(6,4 ( 2-1/4"DIA. (12,7±3,2 mm) mm) / (57,2 mm) / ~ (57,2 mm) FACE OF MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING (3,21 m 1/8" / mm) / (3,2 mm) „7,4._ T r.. 1 PTi 7i I!, % 1�-i 'i. MOUNTING �Ij MOUNTING SURFACE SURFACE M 111 V CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 14 FIGURE 15 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3M INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3M INCH NPT 8.0 K-FACTOR,3M INCH NPT TFP171 Page 10 of 10 P/N 57 - XXX- X- XXX SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 3 PURE WHITE 1 155 155°F(68°C) POLYESTER(RAL9010) 340 4.2K UPRIGHT(1/2"NPT) TY2131 4 SIGNAL WHITE 175 175°F(79°C) POLYESTER(RAL9003) 341 4.2K PENDENT(1/2"NPT) TY2231 5 JET BLACK 2 200 200°F(93°C) POLYESTER(RAL9005) 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 NOTES: 1. Eastern Hemisphere sales only. 391 8.0K PENDENT(3/4"NPT) TY4231 2. Available in only 2.8K,4.2K,and 8.0K,155°F(68°C) and 200°F(93°C);requires lead time to manufacture. 360 8.0K UPRIGHT(1/2"NPT) TY4831* 361 8.0K PENDENT(1/2"NPT) TY4931* TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify)finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify*) finish,P/N(specify*) Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 *Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway,Lansdale,PA 19446 Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation. Fire Protection Products FireLock® V27, K5.6 ✓ctaulic Models V2709,V2710 40.11 Standard Spray Technical Specifications: Horizontal and Recessed Horizontal Sidewall Standard and Quick Response Models:V2709,V2710 Style: Horizontal Sidewall or Recessed Horizontal Sidewall .,� ' 1 :- { ��� Nominal Orifice Size: 1/2713 mm K Factor:5.6 Imp./8.1 S.I.1 Nominal Thread Size: 1/2'/15 mm V2709/V2710 V2709/V2710 Max.Working Pressure: Standard Horizontal Recessed Horizontal Sidewall Sidewall • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Approvals/Listings: Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa O4� Fnn Min.Operating Pressure: LPCBJ • 7 psi/48 kPa See Victaulic Publication 10.01 for more details. Temperature Rating:See chart on page 3 1 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. Product Description: These Model V27, standard spray horizontal sidewall / sprinklers are designed for up to ordinary Hazard per NFPA 13, and can be used for standard or recessed installations. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings(see chart on page 3) U �, and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 4/1 S recessed escutcheon which provides up to "/19 mm of a adjustments. 3/4 Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaulic victaulic.com I Sprinklers I FireLock*I K5.6,V27 I Publication 40.11 Material Specifications: Accessories Horizontal Deflector:Commercial bronze per Installation Wrench: UNS C22000 ❑ Open End:V27 Bulb:Glass with glycerin solution ❑ Recessed:V27-2 Bulb Nominal Diameter: ❑ Standard: 5.0 mm Sprinkler Finishes: ❑✓ Quick Response:3.0 mm ❑ Plain Brass Load Screw: Low Silicon bronze per UNS C65100 ❑ Chrome plated Pip Cap: Low Silicon bronze per UNS C65100 ❑✓ White painted3 Spring: Beryllium nickel ❑ Flat black painted3 Seal:Teflon2 tape ❑ Custom painted3 Frame: Die cast brass 65-30 ❑ Proprietary Nickel/Teflon2 coating3 Lodgement Spring:Stainless steel per UNS S30200 ❑ VC-2504 155, 200, 286 SR Only: ❑ Wax3 For cabinets and other accessories refer to separate sheet. NOTE:Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Dupont Co. 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. �Ct:aU�iL1 victaulic.com 2 victaulic.com I Sprinklers I FireLock®I K5.6,V27 I Publication 40.11 Approvals/Listings: Model APPROVALS/LISTINGS V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed • Orifice Size(inches) 1/2" '/2" '/2" '/2" 1/2" Orifice Size(mm) 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.I 5 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Quick Quick Quick , Recessed Recessed Recessed Horizontal Horizontal Horizontal Horizontal Deflector Type Sidewall Horizontal Sidewall Sidewall(up to Sidewall(up to Sidewall* 3/2"adjustment) 3/a"adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C135°F/57°C 135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C155°F/68°C 155°F/68°C cULus 200°F/93°C 175"F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C155°F/68°C 135°F/57°C 175°F/79°C 155°F/68°C155°F/68°C FM 6 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C None 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C135°F/57°C 135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C155°F/68°C 155°F/68°C NYC/MEA 6#62-99-E 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C135°F/57°C 135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C155°F/68°C 155°F/68°C CSFM 6#7690-0531:112 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286"F/i41°C i35"F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB 6104b/01 175°F/79°C None 175°F/79°C None None 6104b/02 200"F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 135°F/57°C135°F/57°C 155°F/68°C 175°F/79°C 155°F/68°C155°F/68°C VNIIPO 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C None 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C CCCf ZSTBS None None None None 155°F/68°C 5 For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 6 Light Hazard ONLY Note:Listings and Approvals as of printing.All are approved open. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictauIic victaulic.com I Sprinklers I FireLock®I K5.6,V27 I Publication 40.11 Dimensions: 3"/89 mm 2Y''/57 mm I■ 7 7 11 3i6'/L 1 /16"/ 32 mm I•��I®� I 8mm. ----- /�T Ili Q � i-- 11 mm lii i���. Standard HSW—V2709,V2710 11/16'/ 17 mm x_23/16my"/ 17/16" 11/16'/ 4y56 mom �� p �, 43 mm 30 mm lliMMESt 4-12"/1022-305 mm Finished Ceiling 4 127102-305 mm � Finished Ceiling Per NFPA I4 Per NFPA 02 _Ii 2751 mm 23/8760 mm . I 2'/51 mm 23/8"760 mm !� �,1 Min.Hole Max.Hole 275/1m/ 'C —ill Min.Hole Max Hole Illi IN I I In—I Finished Surface 4 f Finished Surfac- }.-Typical Wall Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 1/2"Adjustment Recessed—V2709,V2710(drawing not to scale) 15/16"/L 24 mm yr_23/16"/ 9/16"/18 mm 7/16' 5/16" �y56 mm 37mm �377mmmmm gyy Finished Ceiling 1— Finished Ceiling 4-127102-305 mm ' 4-12"/102-305 mm ,� Per NFPA s Per NFPA IY pi Min.Horn Max Hole 75 mm �� �■ mm 23/8'/60 mm 2/51 mm 23/8'/60mm 1...-- I 2'/51 215/16'/ C TI Min.Hole MaiHole _1. I II Finished Surface I�II Finished Surface I�I +1 A.- Typical Wall +F Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 34'Adjustment Recessed—V2709,V2710(drawing not to scale) 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictauli victaulic.com I Sprinklers I FireLock®I K5.6,V27 I Publication 40.11 Distribution Patterns: Models V2709,V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory .4 s . v 8' ... .. .,_. .,.. • I ..._ _.. .,.. i -••-••. 2.4 m K t ..a -. ` ..,_.....A1• fi kPa ' ,. •,4 48 kPa 6 ' 44 1.S m # ry `; � i �',�.., ,V 15 psi �� P +,� f e .4 103 kPa 1.2 m i r _, ,.... . 2, 207 kPa �4 0,6 m I i\ r I I 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6m 1,2m 1,8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m Models V2709,V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns-Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3.Om 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 8Sm 2 I• _ _. i 0.6m •, ■ •• g 4' 1.2m 1.. s 7psi �••1••. 6' _ �__. 48 kPa 1.8 m j � i � 15 psi 2.4m _. .. _..�+• t •..... 103 kPa r•• /I30m •....••�••� psi r�..r•* t _._._! I 3207kPa 41 12' a • 3.7 m _... _ •• 14' • 4.3m •*• ...............•....... . ... ....• 16' .._..... _ . _... ._._ • .. . . ._. _. , 4.9 m _. _.. NOTES: A.Data shown is approximate and can vary due to differences in installation. B.These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓ctaulic victaulic.com I Sprinklers I FireLock®I K5.6,V27 I Publication 40.11 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from-67°F (-55°C)to those shown in the table below. V27-2 V27 Recessed Open End Temperature-°F/°C No escutcheon ✓ ✓ Maximum With escutcheon / - Sprinkler Victaulic Nominal Ambient Glass Temperature Part Temperature Temperature Bulb Classification Identification Rating Allowed Color OrdinaryA 135°F/57°C 100°F/38°C Orange --->" Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/93°C 150°F/65°C Green High J 286°F/141°C 225°F/107°C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple - M Open - No Bulb Standard response only. • Always read in , ,and maintenance instructions,supplied with each box of sprin- t klers,before proceedingand with installation ofcareany sprinklers. • Always wear safety glassesunderstand and footstallationprotection. • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that supplied by Victaulic)is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31,Easton,Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. cr7 Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications.All products Installation and Maintenance Sheet for the product you are installing.This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications,designs and standard data,and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. �CtaU�iC victaulic.com 6 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 ` �L us SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE This Model V27 residential sprinkler is designed to meet the requirements of NFPA 13, 13D and 13R for residential use in a variety of room sizes,depending upon available operating rifir) pressure and room configuration.The design incorporates state-of-the-art,heat responsive, frangible glass bulb design(quick response)for prompt,precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.This sprinkler is available in various finishes to meet many design PENDENT requirements. (V2740) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid.During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE: Residential spray coverage up to 20 feet x 20 feet/6.1 m x 6.1 m room sizes per NFPA. TECHNICAL SPECIFICATIONS: Model:V2740 ACCESSORIES Style:Pendent and Recessed Pendent Installation Wrench: Nominal Orifice Size:%6712 mm • Open End:V27 K-Factor:4.9 Imp./7.1 S.I.^for room sizes up to • Recessed:V27-1 L.) 2076.1 m Sprinkler Finishes: Nominal Thread Size:11/2"NPT/15 mm • Plain brass r Max.Working Pressure: 175 psi/1200 kPa • Chrome plated Factory Hydrostatic Test: 100%@ 500 psi/ • White painted** i n.OpePa Custom painted** Min.Operating Pressure:7 psi/48 kPa For • escutcheons,cabinets and other accessories 4jiiTRating:See chart on page 3refer to separate sheet. � MATERIAL SPECIFICATIONS ^For K-Factor when pressure is measured in 1-----;._ . Bar,multiply S.I.units by 10.0. Pendent Deflector:Bronze per UNS C51000 *Teflon is a registered trademark of Bulb:Glass with glycerin solution Dupont Co. Bulb Nominal Diameter: **UL Listed for corrosion resistance in all __ I • Quick Response:3.0mm Si- configurations. Load Screw:Bronze per UNS C65100 NOTE:Weather resistant recessed escutcheon Pip Cap:Bronze per UNS C65100 available upon request. 16 m 4 Seal:Teflon*tape a4b_ Frame:Die cast brass 65-30 Exaggerated for clarity JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. rL'+taLJ�ICji REV_E 40.47_1 r o FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K€Factor Response Deflector Type "F/`C t Inches Imperial mm 8.1.° cULus • V2740 12 �1 Quick - Pendent i 68 1759 V2740 'T6 4'9 T Quick Recessed Pendent 155,175 12 71 I Up to IN Adjustment* I 68,79 V2740 7/16 4.9 Recessed Pendent I 155,175 Quick 12 Z1 Up to 34"Adjustment# 68,79 *Listings and approval as of printing. A For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0. *For 12 x 12 to 20'x 20'rooms #For 12'x 12'to 18'x 18'rooms RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Temperature—'Fit Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color -> Ordinary C I fib I 10$ Red �,,. .. L...,....u..._.._ ..,..... 175 - - Intermediate E I 79 5 I Yellow I ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating .], K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt'auIuC* 40.47_2 REV_E FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding with installation of any sprinklers. C • Always wear safety glasses and foot protection. Ir • Depressurize and drain the piping system before attempting to a.. ' install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that 0 supplied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be rPfollowed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31,Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. AVAILABLE WRENCHES Sprinkler Type Open End Recessed V2740 Pendent V27 V27-2 V2740 Recessed Pendent — V27-2 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaUlic. REV E 40.47 3 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE DIMENSIONS Standard Pendent—V2740 I in__ ,..s z3/4^/ 60 mm 1 s/a/ II 41 mm ..‘_._.,... 1W,J 30 mm Maximum Recess—'"Adjustment Recessed—V2740(drawing not to scale) 1`2W/S0 mm Max.Hole 2/51 mm Min.Hole ` ire% UtFsl� �lv �� e.. 3omm ��I. ` .I(7gj�p Typing Tile 7QY� TYP�calCeilingTile '� %�/LI1/� 17 mm ��/ " ��- P1d/ 1 Finished Surface 30 y1mm `.J Finished Surface 43 mm 1IPJ 1 'I? MAXIMUM RECESS 2'31./ 75 mm MAXIMUM EXTENSION Maximum Recess—3/a"Adjustment Recessed—V2740(drawing not to scale) 23b"/60 mm Max.Hole 7'/51 mm Min.Hole 1 �� 12 / ��� LLi>iel1 i ' s^/ �� _ I�� 37 mm �i /I/I I Ara 24 mm 8m 7020 ui Typical Ceiling Tile L ,�YH��,� Typical Ceiling Tile 18f m Z, .�, ` f l ../ i 24 mm Finished Surface we/ 113 Finished Surface43 mm MAXIMUM RECESS 2%"/ 75 mm MAXIMUM EXTENSION www.victaulic.com viCtaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_E 40.47_4 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE ROOM SIZE Victaulic V2740,4.9 K-Factor Pendent Sprinkler For Ceiling types refer to NFPA 13,13R or 13D 2013 Editions Max. Ordinary Temp Intermediate Temp ' Coverage Rating Rating Deflector to Installation Minimum Area° 155°F/68'C 175'F/79`C Ceiling Type Spacing Flow• Pressure . Flow,. Pressure' Ft.x Ft. GPM PSI GPM PSI Ft. m x m L/min bar L/min bar m 12 X 12 I13 ¢ 7.0 13 7.0 3.7 X 3.7 49.2 1 0.48 49.2..,_4..t_0.48 I 14X14 13 7.0 13 I 7.0 4.3 X 4.3 49.2 0.48 49.2 0.48 3/a"recessed 16 X 16 13 7.0 13 70 Escutcheon)l 8.0 3 4.9X49 492 048 • 492 048 1/,ato4inch or non-recessed 2.4 ..t per NFPA 13,13R 18X18 17 12 17 12 or13D 55 X 5.5 64.3 0.83 64.3 0.83 r 20 X 20 i 20 16.7 20 16.7 6.1 X 6.1 75.7 1.15 75.7 1.15 I (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)For NFPA 13 residential applications,the greater of 0.1gpm/ft2 over the design area of the flow in accordance with the criteria in the table must be used. (c) For 20 x 20 Coverage Area-'/'Maximum Recess www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic° REV_E 40.47_5 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent and recessed pendent(V) 13 GPM/49.2 LPM—16'x 1674.9 x 4.9 m coverage area 8' 2 15m ..,.k.�„.q „�.... r 2 „,, rx 0.6 0 .. 19m lar” t1.6m 12 06 1 0'1.w:. 06. CL OFROOM Model V2740 K4.9 residential pendent and recessed pendent(34°) 17 GPM/64.3 LPM—18'x 1875.5 x 5.5m coverage area B' 21m �. I 1 1 _ Ohm! ,.� 89 1 ' 2am 2Gn.iem tem Odm 1.. 8m E 03m= tzm See notes on next page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jCtaulid 40.47_6 REV_E FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent and recessed pendent(tW) 20 GPM/75.7 LPM—20'x 2076.1 x 6.1 m coverage area 12m 0.9m _.. .... - ..w w 0.6mh.,, 6 2.4m 3.➢m 24m tam 11 Dom 03M1 CL OFMOpM .., NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.aul,c REV_E 40.47_7 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.47 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.47 4525 REV E UPDATED 04/2013 ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.47 • FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40. 10 V27, K5.60 FM ® (LPCB1 " SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V27O3 AND V27O7 STANDARD RESPONSE MODELS/S.I.N.V27O4 AND V27O8 QUICK RESPONSE ;" These Model V27 standard spray sprinklers are designed to produce a A hemispherical spray pattern for standard commercial applications.They are available with either standard or quick response bulbs.The design incorporates state-of-the-art,heat responsive,frangible glass bulb design(standard or quick response)for prompt,precise operation. UPRIGHT PENDENT RECESSED The die cast frame is more streamlined and attractive than traditional sand cast (V2703 AND (V2707 AND (270p ENT D V2704) V2708) frames.It is cast with a hex-shaped wrench boss to allow easy tightening from many v2706) angles,reducing assembly effort.This sprinkler is available in various temperature ratings(see chart on page 2)and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to W/19 mm of adjustments. SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid.During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient tem- perature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement,refer to NFPA 13 standards. TECHNICAL SPECIFICATIONS Models/S.I.N.:V27O3,V27O4,V27O7,V2708 Style:Pendent, Upright or Recessed Pendent ACCESSORIES ® Nominal Orifice Size:W/13 mm K-Factor:5.6Imp./8.1S.1.^ Installation Wrench: Nominal Thread Size:W NPT/15mm • Open End:V27 Max.Working Pressure: Recessed:V27-2 175psi/1200kPa FM Global Finishes: 0250psi/1725 kPa UL • Plain brass Factory Hydrostatic Test: • Chrome plated 100% 500psi/345OkPa • White painted** li �,,`j Min.Operating Pressure:7psi/48kPa • Black painted** �' Temperature Rating:See charts on page 2&3. • Custom painted** • Proprietary nickel Teflon*coating** laII MATERIAL SPECIFICATIONS • For 155,200,and 286°F Standard ►�v Response Only,wax coated** ,� Upright Deflector:Bronze per UNS C22000 `I Pendent Deflector:Bronze per UNS C510O0 For cabinets and other accessories refer to Bulb:Glass with glycerin solution. separate sheet. "moi Bulb Nominal Diameter: 1.1 Standard:5.Omm NOTE:Weather resistant recessed escutcheons• • Quick Response:3.0mm available upon request. Load Screw:Bronze per UNS C651OO A For K-Factor when pressure is measured in Pip Cap:Bronze per UNS C651O0 Bar,multiply S.I.units by 10.0. Spring:Beryllium nickel * Teflon is a registered trademark of Dupont Co. Exaggerated for clarity Seal:Teflon*tape **UL Listed for corrosion resistance in all Frame:Die cast brass 65-30 configurations. Lodgement Spring:Stainless steel per UNS S30200 JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.CO 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓atalullc REV I 40.10_1 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE Model Orifice APPROVALS/LISTINGS v27o3 i vz7o7 v27o7 112704 112708 v27o � } Size(inches) ; -� " 13 F ° 13 . —Orifice Size(mm) 13 13 "' 13 13')` 5 6 6 5 6 Nominal K Factor Imperial 5.6 5.6 =... - Nominal K Factor S I 81 i v.81 .. uick ..z Quick Standard Standard Standard 1 ,,_.Quick __ g Response 1 I Recessed � _ Pendendt I Upright I Pendent I pendent Deflector Type I . z Upright I Pendent up to a"' j .._ .., up tO a/4 f E Approved Temperature Ratings F'/C"by Agency 135°F/57°C I 135°F/57°C i ._. ... .. 135°F/57°C 1t ;i 3F/5 °C r 1!Lii °C i 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 5F/6 °C 1 °C 155°F/68°C175°F/79°C 175°F/79°C :+ 175°F/79°C °C 1UL 200°F/93C i 200F/93C °C 2 °C 200°F/93°C 366°F/181°C 360°F/181°C ! 286°F/141°C 1 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C .. .. . 135 F/57°C 135 F/57°C ! 135 F/57°C ° ` 155°F/68°C 135°F/57 C 135°F/S7°C I 135 F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C l 155°F/68°C 175°F/79°C / 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C ULC 200°F/93°C I 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200 /93 286°F/141°C 286°F/141°C { 286°F/141°C I 286°F/141°C ' 286°F/141°C , I 360°F/182°C I,_.. 360 F/182°C ° 135°F/57°C 135'F/57'C I 135°F/S7°C 135°F/57°C F 135°F /57 C 155°F/68°C I 155°F/68°C 135°F/57°C I 155'F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 1 175°F/79°C 175°F/79°C i; 175°F/79°C FM# I 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 275°F/79°C g 286°F/141°C i 286°F/141°C 200°F/93°C . 286°F/141°C 286°F/141°C I 360°F/182°C I 360°F/182°C 135°F/57°C 135 F/57°C 135°F/57°C 135°F/57°C 135°F/57°C ! 135°F/57°C E 155°F/68°C I 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C I 155°F/68°C 175°F/79°C i 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C ; 175°F/79°C NYC/MEA#62.99-E 6 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C ''. 286°F/141°C I 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 4 I. 360 F/182°C 360 F/182°C I w_... . 135°F/57°C 135 F/57°C 135°F/57°C 135°F/57°C I 135°F/57°C 135°F/57°C 155°F/68°C t 155°F/68°C 155°F/68°C 155°F/68°C I 155°F/68°C i 155°F/68°C 175°F/79°C I 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C CSFM#7690-0531:112 200°F/93°C i 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C I 200°F/93°C I 286°F/182 C ; 286°F/141°C 360°F/182°C � 286°F/141°C ' 286°F/141°C 286°F/141°C l i I 360°F/182°C ......—..._ ...,,,...I I 135°F/57°C 135°F/57°C I I I 155°F/68°C ( 155°F/68°C 135°F/57°C 135°F/57°C None 175°F/79°C i 175°F/79°C 175°F/79°C 175°F/79°C None LPCB i 200°F/93°C 1 ( i I 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 360°F/182°C . ._ —.,- S 135°F/57°C 135 F/57°C 135°F/57°C 135°F/57°C 4 135 F/57°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C ! 155°F/68°C 175°F/79°C 175°F/79°C I 155°F/68°C 175°F/79°C 175°F/79°C 175°F/79°C YNIIPO- • 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C i200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286 F/141 C 360°F/182°C ' -1 360 F/182°C --.,m..mry _ _ m„��_._ I � K-ZSTZ € K-ZSTX ZSTZ ZSTX I CCC 155°F/68°CI 155°F/68°C 155°F/68°C 155°F/68°C one None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C #Listings and Approvals as of printing.All are approved open,except for areas designated"No ^For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 #FM Approved with 1/2'adjustment escutcheon only-quick response www.victaulic.com \iCtaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV _I 40.10_2 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature—`FPC Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color Ordinary A 57 108 Orange 155 10 Ordinary C 68 08 Red Intermediate E 175 150 Yellow 79 65 Intermediate I 200 150 Green 93.,. . .. 65,.._., 286 225– Blue High 1 i 141 107 300_.. :.._..,..,.�.. ...,. .N_....... Extra High# K 182 149 Purple # M Open — No Bulb #Standard response only. All are approved open,except for areas designated"No". —150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com jctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_I 40.10_3 FIRE PROTECTION PRODUCTS–AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding with installation of any sprinklers. - C • Always wear safety glasses and foot protection. lip1 , • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. Os ,ping, ces t pliedPaintingby Victaulic)is notany allowed.re- Failure to follow latthese or instructions couldoatingof resultsprinklinrserious(other personal sup- injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection 0 Association document NFPA 25 that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31, Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. DIMENSIONS Standard Pendent–V2707,V2708 Standard Upright–V2703,V2704 r37m f171..._ ___,,,Hei 23'4"/ 60 mm tie"/ roil 41mm , 0 2N"/ 41mm 60 mm jilt PM1"/ — 25 mm 1"Adjustment Recessed–V2707,V2708(drawing not to scale) 2MaxW/60 mm .Hole 2"/51 mm Min.Hole I "may 7j//� �Ij//�Qr tl;,_iilt, 1 "/ 7 m��di��''u D�I1Ii TYPical Ceiling Tile A ff r Ill1 11%f4iOj//�3 m I. —1 ‘1$ isAei 43 mm ��'�I Finished Surface ■ 30•m —•—, MAXIMUM RECESS 2°/d/ 75 mm MAXIMUM EXTENSION www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulace 40.10_4 REV_I FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DIMENSIONS 3A"Adjustment Recessed—V2707,V2708(drawing not to scale) 2W/60 mm Max.Hole—.- 21/51 mm Min.Hole — I IR: i11 '"/ Ae% MEP 1 MI 37 m 2477 �j=rillIV --:11__ A,---1--_Typical Ceiling Tile ��,���, tI 11 �LIIUYI� �_A .As% iii A . 24 mm I Finished SurfaceI MAXIMUM RECESS 2'HSd/ 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V27-2 Recessed V27 Open End V2707,V2708 Pendent yes yes V2707 V2708 Recessed Pendent yes — V2703,V2704 Upright yes yes DISTRIBUTION PATTERNS Models/S.I.N.V2707,V2708 K5.6 standard pendent and recessed pendent distribution patterns—trajectory 10' __ .... .... ._.�,....... ....... .. ._.... .,„„F _., .m.._... ... i..... .—1307 •� �.... ... I i I 4 .I 1 I S I • 2.47 i ♦ � I E 1 NI . ♦ I 3 __..._ 1- , 1.8m ' ' i\• ( ♦♦I •I .,. _........,_.. _........... �._._.. t_. `* ♦ ..,. _ ♦♦ ,.. . _,,, . _. 41 rr ' _.__.� .wa 1.2m , ..t p I t I ♦44 , I r ♦ I 0.6m I I E 1 1 • • .,.,._ .. . ._.. ♦ ♦♦ i , • Ii ..m _,.,.♦ t `, I € ♦ 0 i. _ .1 . , .,J . + 2' 4' 6' 8' 10' 12' 14' 0.67 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7 psi "�"' 15 psi sr•mm - 30 psi 48 kPa 103 kPa 207 kPa See notes on next page. www.victaulic.com \iCtaulic° VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_I 40.10_5 FIRE PROTCTION PRODUCTS-AUTOMATIC SPRINKLERS 40. 10 V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models/S.I.N.V2703,V2704 K5.6 standard upright distribution patterns—trajectory 10' 3.0m 8 • E �O i •.. ### •I g ... 2.4m ? �. i. . 4v # 6 I • • 4 . '# i £ i ♦ £ F 2' € i # i . 4 0.6m ,_....._. _. ...1..._. �,r,.1. . .......,.... ..4 k, ..._._• 4 _. i a t ` ##n._ 2' 4' 6' 8' 10' 12' 14' 16' 0.6m 12m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m 7 psi 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.10 2544 REV I UPDATED 04/2012 ictaul,c VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 V36, K5.6 ® FM c LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall Iii.' V3609 STANDARD RESPONSE „ I V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL 4 .,6* ... -'- ,iII ,a,, EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL The V36 dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model V36 Dry Type Horizontal Sidewall Sprinkler utilizes a frangible glass bulb.At the bulb's rated temperature,the sprinkler opens releasing the bulb seat assembly,causing the inner tube assembly to move,allowing the spring assembly to pivot alongside the inner tube.At this time,water flows through the sprinkler and is distributed by the deflector,in an approved discharge pattern. The heart of the Model V36 sprinkler's proven actuating assembly is a hermetically sealed frangible glass bulb that contains a precisely measured amount of fluid.When heat is absorbed,the liquid within the bulb expands increasing the internal pressure.At the prescribed temperature the internal pressure within the bulb exceeds the strength of the glass causing the glass to shatter.This results in water discharge which is distributed in an approved pattern. COVERAGE: For coverage area and sprinkler placement,refer to NFPA 13 standards. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jctaulic° REVI 40.64_1 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.64 V36, K5.6 41, FM LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall - 5•' rail y 1�= �' 410.4. •11-40-)... . ` V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL /101E EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL TECHNICAL SPECIFICATIONS: I 1•410 mil 1 ' 1 'ic 66-41,,,.r�.T..s�ArArAsrisris6srisGsFFiYis�I � ill I Exaggerated for clarity Models:V3610 and V3609 ACCESSORIES Style:Horizontal Sidewall and Recessed Installation Wrench:Model V36 Open End and Horizontal Sidewall Recessed Wrenches fit all V36 Series frames. Nominal Orifice Size:W/13 mm Finishes: Orifice Insert:Stainless steel per UNS S30300 • Plain brass K-Factor:5.6 Imp./8,1 S.1.^ • Chrome plated° Nominal Thread Size:1"NPT/33.7 mm • White Painted° Max.Working Pressure:175 psi/1200 kPa • Flat black painted° Factory Hydrostatic Test:100%@ 500 psi/ • Custom painted° 3450kPa • Wax° Min.Operating Pressure:7 psi/48 kPa • Proprietary Nickel Teflon*Coated° Temperature Rating:See chart on page 3. For cabinets and other accessories refer to separate sheet. MATERIAL SPECIFICATIONS A For K-Factor when pressure is measured in Deflector:Brass per UNS C22000 or Stainless Bar,multiply S.I.units by 10.0. Steel per UNS S30400 * Teflon is a registered trademark of Dupont Co. Bulb:Glass with glycerin solution ° UL Listed for corrosion resistance in all con- • Standard:5.0mm figurations. • Quick Response:3.0mm NOTES: Split Spacer:Stainless steel per UNS S30300 1.Weather resistant escutcheon available upon Load Screw:Brass per UNS C36000 request. Pip Cap:Stainless steel per UNS S30300 2.Only the Plain Brass and Nickel Teflon Spring Seal Assembly:Teflon*coated Beryllium finishes are FM approved. nickel alloy and Stainless steel per UNS S30300 Frame:Die cast brass Outer Tube:Galvanized steel pipe Inner Tube:Stainless steel per UNS S30400 Escutcheon:1010-1018 mild steel and Stainless Steel Torsion Spring:Stainless Steel Wire www.victaulic.com 1Ctauiic° VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_I 40.64_2 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.64 FM V36, K5,6 co LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall - k: , 1411k V3609 STANDARD RESPONSE ,k,, a FFFRRR V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL Tw ` EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type F/'C J." Inches Imperial Standard mm 5.1.^ or Quick UL* C-UL* FM V3610 1h 5.6 i I 155 200 286.135 155 200 286 135,155 200 286 13 81 Quick € Horizontal Sidewall i13:,7,68 93 141 i 57 68 93 141 57,68 93 141 5.6 V3610 Qulck I Recessed Horizontal 135,155,200,286 135,155,200,286 135,155,200 13 8.1 Sidewall 57,68 93,141 i 57,68,93,141 , 57 68,93 V3609 13 8.6 Standard Horizontal Sidewall 135,155 200 2861 135,155,200,286 135,155,200,286 i 57,68 93 141 57 68,93,141 57,68,93,141 V3609 13 58.6 Standard Recessed Horizontal i135,155 200,2864135,155,200,286, 135,155,200 Sidewall 57,68,93,141 57,68,93,141 I 57,68,93 #Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. *Light Hazard Only-Listed for light hazard only with deflector from 4"-12"below the ceiling. **Approved for V3609 and V3610 up to 48"length. RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature-°F/°C Sprinkler Temperature Nominal Temperature Maximum Ambient Classification Rating Temperature Allowed Glass Bulb Color Ordinary 135/6155 i 100 ....200 .... 38 ` Orange/Red Intermediate 93 I 150 Green 65 286 2 r High 141 I 107 Blue www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Ctaul1e REV_I 40.64_3 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 4!) .<>- C V36, K5.6 LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall andu Recessed Horizontal Sidewall 'rP. "- I V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL Y.n 1101E EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Quantity ._..��_ ... Sprinkler Finish Escutcheon Style "A"Dimension-Distance from face of fitting to the finished ceiling line regardless of escutcheon used. AVAILABLE WRENCHES Model V36 Open End and Recessed Wrenches fit all V36 Series frames. www.victaulic.com ,Ctau1ic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.m 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV 40.64_4 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 `{(/ K K5. V� FM c® ` 6, USTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall ; V3609 STANDARD RESPONSE `'s °'" V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers,before proceeding 0 with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction,must be strictly followed. • Painting,plating,or any re-coating of sprinklers(other than that sup- 0 plied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition.For minimum maintenance and inspection requirements,refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems.In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be 0followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters:P.O.Box 31,Easton,Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt.'c7UI1�i REV_I 40.64_5 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 V36, K5.6 ® FM .0 LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall V3609 STANDARD RESPONSE ' ++ 1 = V3610 QUICK RESPONSE t'r FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL OE -- ill ..' T.m EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DIMENSIONS NOTE:The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer.See IMPORTANT INSTALLATION INFORMATION later in this document. (Min.11/47 .. u" (MlnA;RT' / .." Two Piece / M n 1.'In i ti..-- 11/2"Min Di�/' •..T-..J 1M•M'In.DIa./r Tee wRh sameou[Iet sRe Hole in Wall % 3'Dia T wtmsai oudarsize Holelna as sprinklad size as aprinklerrhread size See IMPORTANT INSTALLATION 21/2' See IMPORTANT INSTALLATION INFORMATION later in this document. j INFORMATION later in this document 4'Max. T Flush Sleeve&Skirt (Mni.1'hT 1'NU I K.�ji ! Ar 6 Tee with same outlet size L 2E" as sprinkler thread see See IMPORTANT INSTALLATION INFORMATION later in this document Plain Barrel 1'NPI (MR 13')I lA Min.Dia Hole in Wall Wall Cup F:__ `it,__ I Collar I II T r, I r1 rNpr Hi . ! D. r{ -4r �.V 1„ ! e, i Irk L'tla f:—:_� i \rr ��Li Dia. Tee with sam�ouder size ___ -I as sprinkler[hr dsve \ Two Piece _� Z•Min aa 1 I See IMPORTANT \ Escutcheon Tee w>(h same outlet size Hob in Wall INSTALLATION as sprinkler thread sue 1S'Min. INFORMATION later in See IMPORTANT INSTALLATION \ 23/4"Max. this document A' 4'Mn,. INFORMATION later in the document. (Mni.IW) 5W Mas \ Extended Recessed DEFLECTOR TO CEILING DISTANCE 4—12"/102—305 MM FOR ALL CONFIGURATIONS SHOWN ABOVE. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. jCtaUkCP 40.64_6 REV_I FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.64 V36, K5.6 "L FM LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall fi M, V3609 STANDARD RESPONSE % '" 1. .••' P t V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL 11011Z. Ca E EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS MODELS V3610,V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS-TRAJECTORY 1 3.0m I3or • ��". aay�r.� .. 8' t•,� ••% 4 • 4' f ••� 1.2 m ,m.. v. , _.v�V ".e- r i�•.. , 2' . •s 0.6m -y ,`. L • 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 7psi -••-•• 15 psi i.mi. 30 psi 48 kPa 103 kPa 207 kPa MODELS V3610,V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS-PLAN VIEW 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 06m 1.2m 18m 24m 3.0m 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 8.5m 2 I .• I 0.6m 1. ... . .. . n ... _ I • 1.2 m E... t .j( t-. .-- 1 a . 1 6' 1.8m .� .. _ ��...w �►. _ w 8' r ♦ I 2.4 m �• ♦ ! 10' ' I :•�•r i 3.0 m .I ._ I ♦• .. 4 ••• • 12 ✓*„� . �,_r A I �,.•••• �, . w 3.7 m ; ••:€%• .i. 14' I •••• 43 m 1 1. ... 16' ♦ l• 4.9m .....v -.�. 7psi -••-•• 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on last page. www.victaulic.com �CtauIic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_I 40.64_7 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 V36, K5.6 FM I: LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall ala i + V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL IMPORTANT INSTALLATION INFORMATION For detailed installation instructions,see publication 1-40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13.These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible,the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18°.Excessive force may distort the frame thus destroying the unit. No.2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee. No.3 DO NOT install dry sprinklers into any couplings or threaded elbows.In addition,DO NOT install dry sprinklers into any fitting that interferes with thread penetration.NOTE:The end seal of the dry sprinkler MUST NOT bottom out in the fitting. �e- 'm NOTE:The"A"dimension of a dry sprinkler,which extends into a End Seal freezer from a wet piping system,must take into account the wall or ' HEATED SPACE zz, ceiling thickness of the freezer.The minimum length of the dry sprinkler : should not be less than the lengths specified in the following table,plus the thickness of the freezer's wall or ceiling("A"="C"+"D"). "C'Exposed Minimum Barrel Refer to the drawing for a representation of the"A"dimension.DO NOT Length(Refer to Table) Diameter of hole is dependent upon the type of esMcheonsel dn.Space must attempt to modify dry sprinklers,since they are manufactured to this be sealed to prevent condensation from specific"A"dimension. forming,per NEPA requirements. The following table is used when the ambient temperature is maintained •A• between 40°F/4°C and 60°F/16°C around the wet piping system. See Note EXPOSED BARREL AMBIENT TEMPERATURE(°F/°C) Insulation ,D• Exposed Minimum Barrel Length Ambient Temperature inches/mm Exposed to Discharge End of Sprinkler 40°F/4"C 501F/101C 601F116°C F/'C Wall or Ceiling of Freezer 40 'i 0 0 0 4 0 0 0 NI I Ir 30 I 0 0 0 -1 0 0 0 I 20 1 4 , 0 0 ■, -7 102 0— 0 r., a:` COLD SPACE 10 [{ 8 M, «W 1 ... w 0 -12 203 25 0 Exaggerated for Oanp' 0 12 3 0 -18 305 I. 76 0 TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY -10 14 4 1 23 356 1 102 25 -20 I 14 6 3 -29 356 152 76 -30 16 8 4 -34 406 . 203 102 -40 1 457 203 102 -50 2010 6 -46 508 i 254 : 152 -60 20 10 6 -51 508 254 152 NOTE:Exposed minimum barrel lengths are inclusive up to 30-mph/48-kph wind velocities www.victaulic.comw, VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. www.victaulic.com ‘/CtaUliCP 8 REV_I FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.64 V36, K5.6 0 <> c LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and ��y Recessed Horizontal Sidewall f-4.410144 V3609 STANDARD RESPONSEa'' ) <i e� I J. V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin- kler spacing rules for installation.Refer to the appropriate NFPA National Fire Code and the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. US&WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O.Box 31 905-884-7444 1-610-559-3300 Easton,PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax) 4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com Easton,PA 18040 USA EUROPE ASIA PACIFIC 1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38(fax) 86-21-54253671 (fax) 1-610-250-8817(fax) viceuro@victaulic.be vicap@victaulic.com pickvic@victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 44(0)1438310690 971-4-883-88-70 44(0)1438310699(fax) 971-4-883-88-60(fax) viceuro@victaulic.be UPDATED 12/2009 40.64 3127 REV I ictaulic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.64 RBulletin 016 Rev.E Model DH56 HSW co eia O Model DH56 HSW Recessed (IT. Model DH56 HSW Concealed o Quick Response, DJ 0) Extended Coverage Dry Sprinklers m For coverages up to 28 feet wide and 10 feet long'). 250 psi (17,2 bar) rated. Features: , ° -"max' 1. Coverage for long and narrow spaces such as hall „ w., ' -- ways, corridors, decks and rooms up to 28 feet wide and 10 feet long.(') 2. Deflector to ceiling dimensions are: 4"(102mm)min.to 12"(305mm)max. DH56 HSW 1 3. Minimum spacing between sprinklers 13 feet(4m).(1) 4. Polyester Coated Corrosion Resistant Sprinklers(cULus) 5. UL Listed for extended coverage, light hazard appli- , cations. ; 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi(17,2 bar)applications. 8. Quick response performance. 9. 1" (13mm)adjustment of escutcheon and cover. � 10.Concealed cover plate can prevent the sprinkler from being used for unintended purposes. No exposed DH56 HSW FP Recessed thermal element with the concealed version. 11.Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12.Factory assembled sprinkler&cup, shipped complete with bulb protector for concealed and FP recessed ver- sions. 13.Sprinkler&cup assembly and escutcheon or cover are separately packaged. 14.Cover finishes available in standard white paint, spe- cial bronze, black paint or flat white paint. DH56 HSW Concealed (1)See Fig. 7. with SWC coverplate Approval Organizations a fire the rising ambient temperature melts the solder and 1. Listed by Underwriters Laboratories Inc. and the cover plate is ejected away by springs exposing the UL certified for Canada(cULus) 3mm frangible glass bulb. The use of a 3mm bulb allows 2. NYC MEA 258-93-E quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the Products Description same temperature rating. The Model DH56 are quick response extended coverage Model DH56 dry sprinklers are intended for use in dry sidewall dry sprinklers for use in light hazard applications. and preaction systems to protect areas subjected to freez- The Model DH56 dry sprinkler with SWC cover plate is a ing temperatures and unheated portions inside buildings. concealed sprinkler that uses Reliable's push on/thread off See Fig. 1 for guidelines on using dry sprinklers in wet sidewall cover.This sprinkler has the cup factory mounted systems. and is shipped with a bulb protector that protects the 3mm Environments wherein dry sprinklers are employed can frangible glass bulb during shipping and post installation be corrosive. For this reason, Model DH56 dry sprinklers finishing operations. The DH56 can be combined in the have a special wax fillet placed in the gap between the field with the FP or F2 Escutcheon to make a recessed cup that supports the bulb and the wrenching boss. This dry sprinkler. The SWC cover plate, FP and F2 recessed wax will not interfere with the operation of the sprinkler,and escutcheons have 1/2" adjustment. The SWC cover plate it prevents contaminants from entering the internal portion is attached with 135 & 165 degree solder. In the event of of the drop nipple. The wax must not be removed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 • Application DH56 HSW Concealed with SWC Cover Plate The Model DH56 is a horizontal sidewall dry sprinkler To install the DH56 HSW dry sprinkler with the SWC intended for installation in light hazard occupancies in ac- coverplate as a concealed sprinkler, cut a 21/8" diam- cordance with NFPA 13. These sprinklers are designed to eter hole into the wall as shown in Fig. 6. Temporari- provide fire protection in long and narrow spaces such as ly remove the plastic protective cap, and then use the hallways, corridors, decks and rooms up to 28 feet (8,5m) Model XLO2 wrench (see Fig. 2) to tighten the sprinkler wide and 10 feet(3m)long. They are rated for 250 psi(17,2 until it is secured in the sprinkler fitting. Note:The Model bar) and can be mounted between 4 and 12 inches (102 XLO2 wrench has a notch in it to accommodate the de- and 305mm)down from the ceiling. flector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during General Installation Instructions tightening.Apply a Teflon**based sealant to the sprinkler Model DH56 dry sprinklers must be installed only in stan- threads before installing in the sprinkler. Wrench only on dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) the square boss. DO NOT WRENCH ON ANY OTHER pipe tees in the horizontal position,even at branch line ends. PART OF THE SPRINKLER. It is recommended that the They should not be installed into elbows or pipe couplings sprinkler be protected during plastering and painting op- located on drop nipples to the sprinklers. For these and erations by reinstalling the plastic protective cap. Instal- other fittings including CPVC, the dry sprinkler should be lation is completed by removing the protective cap and installed into a fitting to allow protrusion into the fitting in ac- inserting the coverplate. Coverplate assemblies provide cordance with the diagrams. The "A" dimension of the dry 1/2" (13mm) of adjustment. Final adjustment is made by sprinkler,which extends into a freezing zone from wet pipe turning the coverplate clockwise until the skirt flange systems, should be selected to provide,as a minimum,the makes full contact with the wall surface. Cover removal specified lengths in inches shown in Fig. 1. requires turning in the counter-clockwise direction. Caution; Concealed coverplate assemblies are listed only for Do not install Model DH56 HSW Dry sprinklers into CPVC use with specific sprinklers. The use of any other con- adapter fittings or tees that have an internal obstruction. cealed wall sprinkler or the use of the SWC coverplate This will damage the sprinkler and/or the fitting. Refer to on any sprinkler with which it is not specifically listed will Fig. 8 void all guarantees, warranties, listings and approvals. Note: DH56 and DH56 Recessed Sprinklers have or- DH56 HSW ange bulb protectors to minimize bulb damage during To install the DH56 HSW dry sprinkler cut a 2'/s"diameter PRO- hole in the wall as shown in Fig. 4. Use the Model G3 instal- shipping, handling, and installation. REMOVE THIS TECTION AT THE TIME THE SPRINKLER SYSTEM IS lation wrench (see Fig. 3) to tighten the sprinkler until it is PLACED IN SERVICE FOR FIRE PROTECTION. Remov- secured in the sprinkler fitting. Apply a Teflon* based seal al of the protectors before this time may leave the bulb ant to the sprinkler threads before installing in the sprinkler. vulnerable to damage. RASCO wrenches are designed Wrench only on the square boss. DO NOT WRENCH ON to install sprinklers when covers are in place. REMOVE ANY OTHER PART OF THE SPRINKLER. Installation is com- PROTECTORS BY UNDOING THE CLASP BY HAND. DO pleted by removing the orange glass bulb-protector and as- NOT USE TOOLS TO REMOVE THE PROTECTORS. sembling the slip-on escutcheon to the sprinkler's can. DH56 HSW Recessed with FP Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutch- eon as a recessed sprinkler cut a 25/8" diameter hole in the wall as shown in Fig.5. Temporarily remove the plastic pro- tective cap,and then use the Model XLO2 wrench(see Fig. 2)to tighten the sprinkler until it is secured in the sprinkler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon** based seal- ant to the sprinkler threads before installing in the sprinkler. Wrench only on the square boss. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER.It is recommended that the sprinkler be protected during plastering and paint- ing operations by reinstalling the plastic protective cap. In- stallation is completed by removing the protective cap and inserting the push-on escutcheon. Turn clockwise to adjust the escutcheon against the wall. *DuPont Registered Trademark 2. RECOMMENDED MINIMUM EXPOSED BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DH56 HSW DRY SPRINKLER SHOWN) DMOSED BARREL TE),AMBIENT ARE AMBIENTTEMPERATURE PERAOF PROTECTED 40F/4C 150T/10•C I !VF/ABC AREA*AT THE DISCHARGE END DPOSFD 1II64UN BARREL LEINOTH.* OF THE SPR$OIR (FACE OF TEE TO TOP OF COUNO) iii.AM K( IN.MI) 4OF(4C) 0 0 0 3OF(-7C) 0 0 0 20'F(-TC) 4(101) 0 0 L 1OF(-17C) 8(203) 1 (26.1) 0 DI►ENSDYI OT(-WC) 12(306) 3(75) 0 wooium CMDLE uomicE IDTOSED -1OF(27C) 14(366) 4(101) 1 (25.1) � 1 -2OF(-27C) 14(368) 8(152) 3(75) ..•:::::::::::::::::::: ::::!1 ESCUTCHEON \::::::::: ::::::::::::::::::: \ -30F(-34T) 16(406) 8(203) 4(101) -40'F(-IOC) 18(467) 8(203) 4(101) (HEATED AREA) \••• • •'• • • ''ii` \:::::::::::::::: ::::::::::\ -50'F(-WC) 20(508) 10(254) 6(152) \:::::::::::.:: : :::::::: ♦ it r -6OF(-61•C) 20(508) 10(264) 8(162) \:::::::::::::::::::::::::::::::::\ •THE PROTECTED AREA REFERS To THE AREA BELOW THE CDUNO. SI -� 7. THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE MIP/'I� ___________—__.______—_ ...,SDIA FOR PROTECTED AREA 7EI,IPERAT RES BAT OCCUR BETWEEN THE YALU6 USTD),USE 1HE NEXT COOLER IDGPDM1URE. 11 91€IAN•REQUIRED BARREL LENGTH IS NOT BE SAIi AS THE•A•DIMENSION. �77 :•:•:-:•:•:•:•:•:•:•:•:•:•:\ NOTE.EXPOSED(I811MlIII BARREL LENGTHS ARE INCLUSIVE UP TO 30I(PH WPI \ ... WIND YELOCITES IN THE PROTECTED AREA. \:::::::::::::::::::::::::::::::::::\ (PROTECTED AREA) :::::::::: Technical Data: Maintenance Temperature Sprinkler Model DH56 Quick Response Dry Sprinklers should be K Factor Thread Rating Maximum Identification inspected quarterly and the sprinkler system maintained in Ambient Number accordance with NFPA 25. Do not remove the factory ap- us Metric Size Sprinkler SWTemperature (SIN) plied thermally sensitive wax fillet between the bulb support- 155°F 135°F 100°F ing cup and the wrenching boss. Do not replace this wax with (68°C) (57°C) (38°C) a substitute substance. An alternate substance may interfere 175°F 165°F 150°F with proper operation of the sprinkler. Do not clean sprinklers 5.6 80 1" RA1664 (79°C) (74°C) (66°C) with soap and water, ammonia or any other cleaning fluids. ° 200°F 165°F 150°F Remove dust by using a soft brush or gentle vacuuming. Re- (93°C) (74°C) (66°C) move any sprinkler which has been painted(other than factory applied)or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- Coverage Area aged or operated sprinklers. Prior to installation, sprinklers Maximum Coverage Pressure should be maintained in their original cartons and packaging Area Width x Length Flow Rate psi(bar) ft x ft(m x m) gpm(L/min) until used to minimize the potential for damage to sprinklers 28 x 8(8,5 x 2,4) 23(87,1) 16.9(1,2) that would cause improper operation or non-operation. 28 x 10(8,5 x 3) 28(106) 25(1,7) Model DH56 Quick Response Approval Type: Extended Coverage Horizontal • Quick Response, Extended Coverage. Sidewall Dry Sprinkler Specification • Approved for installation in accordance with NFPA 13 Sprinklers shall be a [quick response -cULus Listed] ex- for light hazard occupancies. tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction with a special deflector capable of providing a discharge over Step 1 a coverage area of 28 ft. (8,5m)wide, and 10ft. (3m) long horizontal throw.Water seal assembly shall consist of a Teflon coated Belleville spring washer. Installation shall permit sprin- kler deflectors to be positioned 4" (102mm)to 12" (305mm) 4 below the ceiling. Sprinklers shall have a nominal K-factor Step 2 of 5.6(80), and 1" NPT thread. Sprinkler temperature rating �. . shall be [155°F(68° C)] and [200°F(93°C)]. Rated working ,rrr pressure shall be 250 psi (17.2 bar). Standard finish: [whit e][chrome][bronze][Special finish-specify]. Quick response extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56,SIN RA1664(Bulletin 016). Step 3 — For recessed EC horizontal sidewall sprinklers: Replace , "horizontal sidewall"with"recessed horizontal sidewall." Add: "°" ,�— ,, (1)Recessed escutcheon assembly shall be a two-piece es- " , ,`-i-- ''o cutcheon of push-on and thread off design with 1" (13mm) adjustment.Standard finish shall be chrome,white and brass. 4--- Quick response recessed horizontal sidewall sprinklers shall Fig.2-XL02 Wrench be Reliable Model DH56,SIN RA1664(Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace "horizontal sidewall" with "concealed horizontal sidewall." Add: Cover plate assembly shall consist of a tbrass cover , plate and copper alloy retainer flange. Method of attaching „„1..,1 .4.s the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" (13mm) cover plate adjust- A ment. Cover plate temperature rating shall be 135°F(57°C) for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C) dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass bulb from damage, which could occur during construction f before the cover plate is installed.Standard cover plate finish: Fig.3-G3 Wrench [white] [Custom Color- specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56,SIN RA1664(Bulletin 016). 4. DH56 HSW DRY SPRINKLER 1 1/2" [38.10mm] Total Adjustment Il _ _ r r — Ceiling — i=r------------------ ----f 1 1/4" [31.75mm] 4" [101.60mm] Min. Escutcheon Adjustment 12" [304.80mm] Max. r-- 1/4" [6.35mm] System Tee i Escutcheon Adjustment 1" NPT ` ; I +; 1 _ -rte N � [1 15/16"m] �;�� lI1IIIIIIIII ILI' !` i IIIIIIIIIII � I ' �� ��� yinI .r 6. Dia. ��� -mil [76.20mm] '- ..__1J - r- T 2 1/8" Dia. 'I G�� Ho a Sinn Wall ^^ 1/4" [6.35mm] Sprinkler Can Protrusion "A" Dimension —i4 Adjustment Nominal Position Range + 1/4" [+6.35mm] of Escutcheon °imaasm - 1 1/4 [-31.75mm] Available "A" Dim. is 2"to 48" (51 mm to 1219mm) in 1/4" (6mm) increments Note: The Sprinkler Can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment provides + 1/4"(+6mm) to -11/4" (-32mm) "A" dimension adjustment range. Fig. 4 DH56 HSW RECESSED DRY SPRINKLER Ceiling i l.J I 1/4" Escutcheon �'�1 [31.75mm] I_I 4" [101.6mm]Min. System Tee Cup i 3 12" [304.8mm]Max.* ---rte 1" NPT W `� __IIIIIIIIII I 3 7/32" Dia. 'l -. of r f, [81.8mm] ...f.-,1`=__„_,` \ �--'LJ tilltI J 2 5/8" Dia. - [66.68mm] Hole in Wall 1 c I Nominal Position 2 9/32" Dia. I of Escutcheon [67.94mm] — 1/4" [6.35] Escutcheon Adjustment "A" Dimension 1/2" [12.7mm] Adjustment Range Escutcheon tchAdjustment 016FG02B ±1/4" 1 [f6.35mm] 1Escutcheon6Ad�u Adjustment Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm)increments Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 5 5. DH56 HSW CONCEALED DRY SPRINKLER ice' Ft *Own Two , 11-1-_iii } sr 1 f Mr ILII Vas m jI I 1 6 II - -1--- ----- - imis I - air kw nos.�a ams sat 1_+p// !µW mow.irrr Ph. lra��] 11-:'--- 1 ® - I C .1 -7 2A � I I ff AW/ —4 11 1 M 9. **NI C*~flan s�rs�d a.►kd�. 016,001Amilt m N amts ARE N 441.06 as(MO Qer' '* '— Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Fig. 6 \ 13' [4m] Minimum Spacing 28' [8.5m] Maximum Spacing MODEL DH56 DRY SPRINKLER r \ WALL Ii.°°/ 4" [100mm] min.From Ceiling 12" [305mm] max.From Ceiling 28' [8.5m] /, 016FGO4A \r� Fig. 7 6. *CAUTION* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. INTERNAL NO INTERNAL OBSTRUCTION OBSTRUCTION Tit FEMALE •` �� FEMALE PIPE /, �1, PIPE . 1, 0 THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL-LINE OF MODEL F3-PL. MODEL F3QR-PL. AND MODEL DH56 HSW-PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. LONGER SHORTER ii INLET INLET -- -� MALE MALE PIPE PIPEPP THREAD THREAD MODEL F3-PL, STANDARD MODEL F3QR-PL OR MODEL F3, MODEL DH56 HSW-PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 016fg08 Fig.8 7. Ordering Information Installation Wrench Specify: Model XLO2 Sprinkler Wrench (Recessed &Concealed) 1. Sprinkler Type(select one): Model G3 Sprinkler Wrench (a)Model DH56 Dry EC HSW Note: A leak tight 1" NPT sprinkler joint can be obtained (b)Model DH56 Dry Recessed EC HSW/FP with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not (c)Model DH56 Dry Concealed EC HSW tighten sprinklers over maximum recommended torque. 2. Sprinkler Temperature Rating. It may cause leakage or impairment of the sprinklers. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. Escutcheon Data: 5. Length: "A" Dimension(face of tee to face of ceiling or FP cup/escutcheon assembly-1/2"(13mm) adjustment wall) in 1/4" (6mm) increments. Finishes (1) Note: Standard Finishes(1) 1. The "A" dimension is based on a nominally gauged Sprinkler Escutcheon Cover Plate pipe thread "make-up" of 0.600" (15mm) per ANSI White Polyester(2) White/Chrome White B2.1 [71/2 threads approximately]. /Chrome/Bronze 2. All platings and paintings are decorative and intend- (1) Other colors and finishes are available. Consult factory for details. ed for interior use. (2)cULus Listed as Corrosion Resistant Sprinkler in standard Black or White. UL Listing Category Note:Paint or any other coatings applied over the factory finish will void Sprinklers, Automatic and Open. Quick Response Sprinklers. all approvals and warranties. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and se -.by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. itManufactured Iiiimili The Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431 1588 Sales Offices Paper liable (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829 2042 Corporate Offices www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 05/10 P/N 9999970308 SPEAKI FlameGuard® CPVC FIRE SPRINKLER PRODUCTS FG-2.0312 Complete System of Pipe, Fittings & Solvent Cement Corrosion Resistant • Superior Flow • Ease of Installation #` Spears® FlameGuard® CPVC Fire Sprinkler Products provide a cost V , effective alternative to metal systems with advantages of high corrosion resistance, improved system hydraulics, ease of installation and quick #+tII l.y pit, , assembly with readily available tools. CPVC Fire Sprinkler Systems are R based on proven CPVC nu SPRINKLERPRODUCTS products that . ! have been in continuous service for over 40 years. Spears®FlameGuard® products are approved by UL®, FM® milk I E Global, LPCB and Certified by NSFNIP i MI 0 International for potable water use. irlb 11.11110 Check local codes for restrictions and 1111111111.1111 limitations. Corrosion Resistant CPVC Material Does Not Easy Installation for Lower Costs Sustain Biological Growth FlameGuard®CPVC system installations significantly Unlike metal systems, FlameGuard®CPVC products never reduce costs over conventional metal piping by virtually rust,scale or pit and do not sustain biological growth-a cause eliminating prefabrication. Systems can be fully installed of Microbiologically Influenced Corrosion(MIC)which can on site using solvent cement joining methods. destroy metal fire sprinkler systems from the inside out. UL®Listed for U.S. and Canada in Superior Flow Characteristics for Lower NFPA 13, ®3R& 13D Systems Friction Losses FlameGuard® CPVC Fire Sprinkler Products are UL® The smooth-wall interior surfaces of FlameGuard® CPVC listed for U.S. and Canada applications for Light Hazard systems result in reduced friction loss over metal systems. occupancies as defined in NFPA 13,Residential occupancies The design flow characteristics remain constant throughout up to and including 4-stories as defined in NFPA 13R, the life of the product because there is no interior corrosion and Residential occupancies for one and two family dwellings and manufactured homes as defined in NFPA in the system due to microbiological activity. 13D.Consult Spears®FlameGuard®CPVC Fire Sprinkler Pressure Rated to 175 psi(1200kpa) @ 150°F Products Installation Instructions and NFPA Standards for (65°C) additional applications including air plenum,system risers, FlameGuard®CPVC Products are produced in combinations concealed, exposed, underground, combustable attic, of Schedule 40 and Schedule 80 Fitting configurations con- garage,basement and low pressure dry piping installations. forming to ASTM F 438 or F 439 standards and FlameGuard® Full Limited Lifetime Warranty SDR 13.5 CPVC Fire Sprinkler Pipe conforming to ASTM F FlameGuard® CPVC Fire Sprinkler Products carry a 442 standards. UL® Rated working pressure is 175 psi limited lifetime warranty against defects in material or (1200kpa)@ 150°F(65°C)(LPCB rated to 120°F)(49°C). workmanship.Consult Spears®warranty for additional details. PROGRESSIVEPRODUCTSFROM °N CERT,p _s % V ` SPEARS®INNOVATION et- W ` � - TECHNOLOGY a LPCB a S Visit our web site: www.spearsmfg.com f SYSTTEEMS Spears® FlameGuard®. . . The Leader in Innovative CPVC Fire Sprinkler System Products Pioneer in Molded-in Metal Insert Head Adapters Spears® pioneered the development of the FlameGuard® molded-in-place metal thread insert for connection of sprinkler heads to CPVC fire sprinkler systems, plus Metal FIPT threaded female adapters for metal-to-plastic transitions. Developed the Special Reinforced (SR) Head Adapters Spears® FlameGuard® continuous improvement program developed the technology to produce a superior patented plastic threaded fitting - the Special Reinforced(SR)Design.This unique design incorporates a patented - thermoplastic compression process that equalizes stresses generated by tapered thread joint make-up. All CPVC plastic body and threads provide a more uniform construction and improved corrosion resistance. Now, the Revolutionary TorqueSafeTM Gasket Sealed 6111:T Head Adapter • Requires NO Thread Sealants • Eliminates Stress • Prevents Over Tightening •Provides Easy Frame Alignment Spears® revolutionary design features a special molded-in-place Brass Thread Insert fitted with an elastomer gasket seal at the base of the threads. The gasket seal allows a modified thread design that eliminates radial stress and associated problems typical with tapered thread joint make up.The insert is designed to rotate for easy sprinkler frame alignment without over tightening. Patent Pending. Full Assortment of Specialty Products & Fitting Configurations Spears® FlameGuard® provides the specialty fittings needed in today's fire sprinkler systems. Like the adjustable drop nipple for fine-tuning to finished ceiling height,and ringed head adapter for ease of locating during installation. Plus, Spears°FlameGuard®line offers a full assortment of CPVC fire sprinkler fitting configurations including Tees, Elbows, Flanges, Couplings, Caps, Male Adapters, Grooved Coupling Adapters and Unions, sizes 3/4" through 3"; with new 3/4" and 1" Repair Couplings. Complete Size Range of CPVC Pipe 11111111 Spears®FlameGuard® CPVC Fire Sprinkler Pipe is available in sizes 3/4" to 3". Conforms to ASTM F 442 standard for SDR 13.5 CPVC pipe. Spears® Solvent Cements & Thread Sealant FlameGuard®products should be installed using Spears° FS-5 One-Step Solvent Cement. For threaded joints, use Spears° BLUE 75'"Thread Sealant that has been tested for compatibility with FlameGuard® CPVC Fire Sprinkler Products. Spears°TorqueSafeTM Gasket Sealed Adapter requires no sealant. Consult sprinkler head manufacturer prior to use. Installation Training Available - Contact Spears® Technical Services for Details FlameGuard®Products must be installed in accordance with Spears®CPVC Fire Sprinkler Piping Products Installation Instructions,National Fire Protection Association Standards 13, 13R, 13D,and in accordance with local codes.Code requirements and field conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. SPEARS® MANUFACTURING COMPANY CORPORATE OFFICE "' (ESI 15853 Olden St.,Sylmar,CA 91342•PO Box 9203,Sylmar,CA 91392 (818)364-1611 •www.spearsmfg.com ©Copyright 2012 Spears®Manufacturing Company. All Rights Reserved.Printed in the United States of America 03/12. FG-2-0312 Iiiii 'fbll Frees 800 828.1268•www.plorwarpips"corn Scope Bending Test (Cold) • Covers black and hot-dipped galvanized furnace butt-welded For NPS 2"and under (continuous welded)Grade A pipe. Pipe Is intended Degree of Bend Diameter of for mechanical and pressure applications and is acceptable Standard MandrelI. 90" . 12 x outside pipe i for ordinary uses in steam,water,gas and air lines. Pipe diameter is suitable for welding,threading,grooving and bending. Close Coiling 90' 8 x outside pipe I diameter Flattening Test I Hot"Dipped ®alvanized As a test for quality of the weld for pipe 2W NPS and larger, i The average weight of zinc coating shell be not less than 1.8 oz.per sq.ft.of surface(inside and outside), position the weld at 90'from the direction of force and flatten until the , OD Is%of the original outside diameter. No cracks shall occur along . When galvanized pipe is bent or otherwise fabricated the inside or outside surface of the weld. . • to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity,some flaking bf the coating Frequency of Tests may occur. Tensile teats are required on each lot of 25 tons or fraction thereof I of pipe NPS 114"and smaller and from each lot of 50 tons or fraction Hydrostatic Testing thereof of pipe NPS 2 and larger. Hydrostatic lest pressures for plain-end pipe are For NPS 2W and larger,a flatteningtest is also indicated below required on each lot of I 60 tons. NPS Std-Weight Extra Strong W through 1" 700 pd 850 psi Dimensions and Weights 1W' through 3" 1000 psi 1300 psi The dimensions and weights furnished under this specification are in • agreement with the standardized dimensions and weights specified in End Finish ASME 836.10. Plain End: • NPS 114"and smaller.unless otherwise specified on order, Permissible Black Plait, G id • end finish shall be at the option of the manufacturer. Variations Soh.40 Soh•80 NPS 2"and larger,STD and XS weights:aids beveled • in Wall Nominal OD Weight Weight Thickness Size inches Wall Ft. Wall LbaJF7 to angle of 30',•FS°,-0'with a root face of tic"*V". 'J+' .405 .068 .24 .095 .31 Minimum wall thick- '1. .540 .088 .43 .119 .54 • Threaded:To ANSI Standard B 1.20.1 near at anpoint shall Via .875 .091 .57 .128 .74 . Y J: .840 .109 .85 .147 1.09 Couplings:To ASTM Standard A 865 not be more than 'J' 1.050 .113 1.13 .154 1.48 1' 1.915 .133 1.88 .179 2.17 • 12.5%under nominal 1'b' 1.680 .140 2.27 .191 3.00 1Ye 1.900 .145 2.72 .200 3.83 Chemical Requirements wall thIcknesa 2" 2.875 .164 356 .218 6.03 specified. ow 2.875 .203 520 275 7.67 Composition,max.% 8" 3.500 .218 7.58 .900 10.25 Carbon Manganese Phosphorus ' Sulfur 30 120 .05 O4$ Permissible Variations In Outside Diameter *Copper idcei •Chromium "Molybdenum "Vanadium NPS 1'/:°and under: .Oi6 40 .15 08 NPS 2"and over: *1% 'The combination of these five elements shall not exceed 1.00%. Permissible Variations Weight Per Foot Pipe shall not vary more than*10%from the standard specified. Tanalla Requirements Tensile Strength,min. 48,000 psi Product Marking Yield Strength Each length of pipe'/.'NPS and larger is continuously stenciled to • min. 30,000 psi show the manufacturer,the grade of pipe(ASTM A53),the kind of pipe • Elongation in 2" Refer to A53 Table X4.1 (F for continuous weld,A for Grade A),the size,XS for extra strong, and length. Legal herein and shall in no event assumes general liabil ty Information or responsibility foroneer makes no anyloss,damage or Injury whrea whatsoever re ulting from the he Implied, this info mation. In ad with ll casect tes,the customer is therefore requested to nse this infomiatioo at its own risk and responsibility. Manistee! North American Pipe&Steel www.napsteel.com IVIiPSteel FIRE SPRINKLER PIPE ,,r North American Pipe & Steel has been a trusted source for steel piping products since 1981. With strong ties to mills in the U.S. and abroad, we are certain to supply "What you need when you need it". Our fire sprinkler line of pipe is another example of our commitment to meeting the needs of our increasing customer base. NAP SuperFlow and NAP Schedule 10 Pipe is: manufactured to ASTM A135, A795 and A53A. UL listed and FM approved for fire sprinkler applications including roll grooved, plain end and welded joints. Yi fully traceable. C BE. AMMO NAP SuperFlow 1 ..rte, ..yaoa 4 4.4.'-',-.S.. .�..,�'„ *! 'ror,:,,;:: .,f., . .. .;, 1-1/4" 1.660 1.494 1.400 61 300 3.70/0.26 ® 2.375 2.185 2.320 37 300 3.58/0.30 r- 3" 3.500 3.320 3.280 19 300 127/0.09 Me 0/ NAP Schedule 10 1-1/4" 1.660 1.442 1.400 61 300 .,, a1 wr '^" is .3 S E 01 .0. Ei,Ai,,., o.... .. EINEM 2.375 HEM 2.320 ® 300 MIMI 7 .....„1 _ e` �. �.. tie 1', ® 3.500 3.260 3.280 19 300 — ... 4 1 fid x = 'r_iz .. NAP Super Row Pipe and NAP Schedule 10 Pipe are manufactured by MS Pipe Co.,LTD,South Korea Surrey,BC Longview,WA Auburn,WA Nampa, ID 11933 Tannery Road,V3V 3X1 7 International Way,98632 3136 B Street NW,98001 2114 Delta Drive, 83687 1-800-665-7473 1-877-735-0275 1-877-735-0275 1-877-735-0275 Ductile Iron Threaded. - K ,f-,,,' , ' '''' t� ' `y�'.1 / �' t's ) t ' \ 1, r, , ,„ ti 1 (.; --, ! Ductile Iron Threaded Fittings ; , , , ; 4 , 1 P i 3 7 'Yt: , , ..:- .:, - . , , , . , . ,, . ,, ,, k , t,, 1 ,'t kr-,, ,,z-,Attvv, • • 44-'44s-----41, 1,- -,•,„, , •• • a • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP • Ductile iron castings conform to ASTM A536 us LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 41> • All fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical &mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPakTM Packaging tiie ' ii r iIt1J1 f� � �. i ,� x -20 to 100 500 "" '" 2'4'Y...T. tnix.3 .'.Y'�5.'. ),tzop� .^::YwL ?I:. ,,':: 200480 *:71a''.'iiv"- K'"' l 'y.5n. a'vi... 4;,A-`,.:17:Z7.:5;:: 300 Q 440f ' 400 c ;: i„,: ,f_ , : _. ! "hot lea * 1' .; , a ` f"' Z: A, ; xis 500 360 Y 600 i320 y4T ",r. iE- XAyN6.,4, w;- Y3 � Y SCI ProPakTM System LE Ductile Iron Threaded Fittings - Class 300 UL/FM • c us APPROVED LISTED Fig. 35E 3-90°Elbow A : M. Its 111 o :' �`_ .�. �, � I�r.;= `' its : -111--- at_ +�� 1/2 35E 3004 100 a- 200 0.2 ��j ,.t 1 r a,� ter k a 0.5. , . 35E 3010 1.50 40 /moi / A 1 .r ,�." t ,.; r #111111r } 1-1/2 35E 3014418 36 � 1.1 2-1/2 35E 3024 "2.70 4 8 3.2 C Fig. 35RE3-90°Reducing Elbow F Q 1,'' : = 6' Lia , 4 ''.♦ 3/4 x1/2, 35RE3006004 ,;,1.20,7,,,, ,,,,,w,,,1.22 80 160 0 3 1 x 3/4 35RE3010006 1 38 1.45 50 100 0.4 J'� �� q 1 1/4 x 3/4 35RE3012006 1 45 1 63 35 70 t , 0.6 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 a 4 t gat 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 s c,; - „sA+.. k FTS•eu' .;4„,!_. . : 71 n, 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 9 a+ i.e '::':11,-;,::. , ! .. `. _„.aaka': 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow , °T 3 ,: �' ;- '� ' : - s alt ,,,4 A 4 r 11 IE �, 1/2 35F 3004 0.88 150 300 0.2 II ri e ;- v, ., 8 1 5 35F 3010 ! 1.13 40 YAC .:';*.r.,...,0 k .;, 0.5 r 1 /kinf A ..-1,-,11.,... 35F 3014 144 20 0.40 44' ..7: 8 2.7 2-1/2 35F 3024 1.95 4 Fig. 35T 3- Tee db. ll 1 ... ASA 4.,,..' -;.,''... '''''1 ' .._'-k.:: ',.,*,,M,*:‘,%,,I;),t*:. 141 .A.-,.:...L...7..".:9,:c ,: 4I(L;�� x `immix 1/2 35T 3004 '1.13 80 160 4'0.3' 1 35T 3010 1.50 25 -----...4 -*;10:4i):4; 20 1 5 e A,i A 1-1/2 35T 3014 1.94 10 • , 2-1/2 35T 3024 2.70 4 8 4.3 201 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com {.. • I Ductile Iron Threaded Fittings - Class 300 UL/FM c01us ® Fig. 35RT3-Reducing Tee LISTED APPROVED lust x >PaI�1 Nulmti,4. 18. ',-.111,,{ s Tri mwur...'4441'''1 " I. `�� C 3/4 x 1/2 35RT3006004 1.20.m 1.20 1.22 60 120 0.4 11:4 -- 1 x 1/2 x 1 35RT30100014010 1 50 36 it;'-i'.56- 30 .5;';6.'0...'''''''';'0.--1111111166 ,=. =-----\����`I i:ef,..�. :! r..�.t`.�f1 `" 4¢ S :T...' '°° �« c VOL: >•.a-* i P• 1- K e5=; f 1 x 3/4 x 3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 D B A ,": * N '4 (" x rt-NWS', 4 C ,ff U 1-1/4 x 1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x314 35RT3012006 1.45 1.45 1.62 15 30 0.9 T .:2 uhf:' �e,,k,„k'..: f-: .. 'UnVailafri J :'&4,i.''',:4P!,710.11.4431 L1-1/4 x1py 35RT3012010€3 +� yy7 y1 58 1.58 )y1 67 15 30 1.0y( g9, sae .iii,: irA�L 1 ''��A 'id. .J 3_L 'er.ts -.7S f4.1, '.r.,v. "'._9 E 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 ."I 114x `� : i)rIa '" Rf - c 1�` . �.. _ i,;h . : , ffi 1-1/4 x 1 x 1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 ,E y, .dna' iA - at I' F N r 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56 1..88 24 48 1.1 88�3 1-1/2 xy3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 .t , .,, �n t �{ '':4:1102: !'!.K-t.:r P s -k €�.1�}�t it f. � . ,,�-. 4WA� n � .' i. .' RPM 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 z "1 r v a 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2 x 1x 1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 F A 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1-1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4x 1-1/2 35RT3014012014 y1.94 1.881 1.94 14 28 1.4 x'( # y Xk '.K E o R k r.1 1 49,I�a 8! k`" }_` I i t 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 o," Poa 2 x 1.1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 M 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 r; sx a ff '• .Yrc� s iia 2 x 1-1/2 x 1 � Y 35RT3020014010� 1.73 1.65 2.02 8 16 1.5 2 yZ 1i ,- + ':;.' .41.0,- ms's{ ..Sst. IA .« 2 x 1-1/2 x 1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35RT3-Bull Head Tee Size ;.;. F A. c , ;aclang "� WeIgi : ailPertt `� r' I.. '�I�.If in A.:,. .. ,t; in -�n:a.; ...in � r Mas#e'�' ��::�b,:!-Ift, ���/ \.,.. �C 3/4 x 1 35BT3006010 1 45 1 45 1.37 30 60 0.6 I��1- 1 x 1-1/4 --44g#004** 7 ° itQ,. °a.. .. 2.,--i B 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 114 xZli 1 t: ,.. , "()I .s1*, i482h;1$ 3' i, A 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 ;:A 4t )t ; `e 12 2O. k F 2'1# I 0- ie f,. ':" 1, .. 1-1/2 x 1-1/4 x 2 35BT3014012020 2.16 2.10 2.02 10 20 1.8 k , . .8NTt3'At)o; .s 16 .x..16 2A2 _ '..s,, , 14 202 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com '7'. Ductile Iron Threaded Fittings- Class 300 UL/FM c43us APPROVED Fig. 35CP3 -Straight Coupling with Ribs LISTED pyo Iliit :„,,,::'.,,,.. p DMI'1r 018r ,.,,, ziAlli;1!..;11,7tli• 1 0 __ 1/2 35CP3004 1.38 200 400 0.1 1 35CP3010 1.75 60 120 0.4 M ,.. 1-1/2 35CP3014 2.19 25 50 0.7 ,z. " ".. '�' a d as a u r w.a ,; e ? .a s> 2-1/2 35CP3024 3.00 9 18 2.2 It Fig. 35RC3 -Hex Reducing Coupling Size '- h packing , Wel h1 ,76-E, ,- i} , , . - lumber a / � m 1£ Inner Master ��lh ;'',M 1 x 1/2 35RC3010004 1.69 80 160 0.3 �; ; 1-1/4 x 3/4 35RC3012006 2.06 40 80 0.6 i `W,'?°, ;1:•,:!.F::•i,..j*;:!ift.R.ii `' °,.:'' , ;: k; Rev Fig. 35HB3 -o t 'Hex' Bushing�q i iiii-j;lita: (tliiiler { f.. I g :ICS. : 11 1 x 1/2 35HB3010004 1.06 1.40 180 360 0.2 lI ; 1-1/4 x 1 35HB3012010 1.19 '1.80 90 180 0.2 1-1/2 x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 d. ..- w p # .. . ...tr. .„rte? „-C 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 + a Fig. 35SP3 -Square Head Plug : a rs "i}i ,:,., 1T- i w '.� i r i .... .F�f f Il �. / 35SP3004 0.94 600 1200 0.07 '`; stig �%�i A .. 1/21 '* '"" {€ . .._.. ,01 .. ". 7 +111 i i �� 35SP3010 1.25 200 400 0.1 1-1/2 35SP3014 1.44 80 160 0.4 ":,p rr w .3'z;r s "':�..6`4:„:1;0@4 n4 :ii i+,,„P,, , z..;,, ' t:.`+ ., p4' 4:,:, Fig. 35U 3-Union with Brass Seat < A > ": ef iM I r v : ; 1 ., .. ifU',, 444.; , ' ` ����� 1 35U 3010 2.19 20 40 1.0 . 1-1/2 35U 3014 2.62 10 20 1.7 3, iia fOli.41.- + + If :' 7T, r„E 0 203 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com • . € Ductile Iron Threaded Fittings - Class 300 UL/FM c us APPROVED A A Fig. 35X 3 Cross LISTED A 1 35X 3010 1.50 20 40 0.9 NI I sr IA 1-1/2 35X 3014 1.94 8 16 1.8 B B Fig. 35RX3 Reducing Cross ssoim �n w n In faster j A 1 1/4 x 1 35RX3012010 1;67 1 58 15 30 1 2 tt mi ,w IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3—Cap ze Pit ;7,11'1.". 1r: kri vow. Ftetit: t 1/2 35C 3004 0 87 300 600 0.1 Arg�i. r� 1..:'... '86'• z ': E�•' ," �'� E..E, s '�: 1'w'r°'3` �`x_ ...1�.:� 35C0 0 1.16 � � �11 O .., 220 � `�Or2`;:,..�ns 1-1/2 35C 3014 1.33 50 100 0.5 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3—Beam Clamp ��� �� .s E . CCI t� ,,> r rt A� : _ .a . f to 0'77172, I� ■ 3/8 35BC3003 4t, 0.75 100 200 0:„3 204 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • wwwsmithcooper.com FireLock® Fittings ✓ctauiie 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. 411 Fitting Coating: ❑ Orange enamel ❑ Red enamel in Europe, Middle East,Africa, and India ❑ Optional: Hot dipped galvanized Approvals/Listings: c0 us FM (PCB] (vas) LISTED Product Description: FireLock®products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I FireLock®Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 C 2014 Victaulic Company.All rights reserved. 1 ictauliC victaulic.com I FireLock®Fittings I Publication 10.03 Dimensions: wCtoE0 tC CtoE i y - o E d.p- O 0 fa-O --k 1 .-T C to tI v o ele E NO.001 NO.003 NO.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approx. Approx. Approx. Approx. Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm mm mm kg mm kg mm kg mm kg 1''A 1.660 - - 0.82 0.3 32 42.4 - - - - 21 0.1 1'h 1.900 - - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21h 2.875 3.00 3.1 2.25 22 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 3.000 3.00 330 2.25 2.4 3.00 3.8 76.1 mm - - 76.1 76 15 57 1.1 76.2 1.7 3 3.500 3.38 4.0 2.50 3.1 3.38 53 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108 mm - - 108.0 102 2.6 76 2.3 102 3.4 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 1143 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 5.500 4.88 12.4 3.25 82 4.88 15.4 139.7 mm - - 139.7 124.0 5.6 82.6 3.7 124.0 6.9 159 mm 6.250 550 12.6 350 9.2 5.50 17.9 - - 158.8 140 5.7 89 42 140 8.0 6 6.625 550 183 3.50 11.7 5.50 22.7 1.00 5.9 150 1683 140 8.3 89 53 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 - - 165.1 139.7 7.9 88.9 5.2 139.7 9.9 8 8.625 6.81 255 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 93 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 iataulic victaulic.com I FireLock®Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' Nominal Outside No.002 Size Diameter Elbows Straight Tee inches inches No.001 No.003 mm mm 90°Elbow 45°Elbow Branch Run 13/4 1.660 - - - - 32 42.4 - - - - 11/2 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 85 3.5 50 603 1.1 0.5 2.6 1.1 2'h 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 23 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 15 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 1143 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 13 63 25 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 15 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 15 7.6 3.0 165.1 mm 6500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No.006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com, equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.03 1539 Rev M Updated 12/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 3ictaulic Victaulic® FirelockTM Rigid Coupling Style 009N ✓ctaulic 10.64 Patented 1.0 CERTIFICATION/LISTINGS crus FM LPCB VdS' C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) ❑ Red enamel (Europe) ❑ Hot dipped galvanized Gasket: (specify choice') ❑ Grade"E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited,and Approved by Factory Mutual Research for wet and dry(oil free air)sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. System No. Location Spec Section Paragraph Submitted By Date Approved Date • victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaulie victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch. 10 Sch.40 Sch.5 Sch.10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 11/4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 11/ 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 21N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 33634 363 363 76.1 mm N/A 2517 3 N/A N/A 2502 4 N/A 2500 2500 3N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 N/A 365 365 175 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 175 363 363 N/A N/A 108.0mm N/A N/A N/A 1205 2502 2502 5290 365 N/A 363 363 232 N/A 125 N/A 2000 2517 2502 2502 1600 363 a N/A N/A N/A 133.0 mm N/A N/A N/A N/A 2502 4 363 a 232 139.7 mm N/A 2 00290 55 N/A N/A 2 02 4 N/A 1600 N/A a N/A N/A N/A 159.0 mm N/A N/A N/A N/A 2502 4 290 a N/A N/A 165.1 mm N/A 20 066 N/A N/A 2502 4 N/A 6290 365 N/A 363 363 232 N/A 150 N/A 2000 2517 2502 2502 1600 4 216.0 mm N/A N/A N/A N/A N/A N/A N/A 2502 a 8290 365 N/A 363 363 232 N/A 200 N/A 2000 2517 2502 2502 1600 2 Listed/Approved for wet and dry pipe systems(>—40F/-40°C)for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Installation Manual l-009N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. �CtauIid victaulic.com 2 victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.1 LISTINGS/APPROVAL Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating cULus FM cULus FM cULus FM inches psi psi inches psi psi inches psi psi kPa kPa kPa kPa kPa kPa 300 BLT 1''/4—2 2068 256 7 EZT 114 2 300 365 MT 1'/4—2 300 365 2068 2517 2068 2517 DF 1'/4-4 2068 2517 FF 11/1-4 300 365 300 365 MLT 11/a-2 N/A 365 2068 2517 2517 DT 1'/4-2 30006 3651 FLF 11/4-4 N/A 365 ST 1'/a-2 N/A 365 2517 2517 175 175 EF 11/4-4 1206 7 06 FLT 11/4-2 N/A 365 STF 11/4-4 N/A 365 2517 2517 300 365 EL 11/4-2 2068 2517 FLTL 11/4-2 N/A 365 TF 21/4-4 N/A 365 2517 2517 ET40 11/4-2 20368 22517 GL 11/4-2 300 365 WLS 1'/4-2 300 365 2068 2517 2068 2517 EZF 3—4 2068 2517 MF 11/4—4 300 365 300 365 WST 11/a—2 N/A 365 2068 2517 2517 300 365 XL 1'/a-2 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 4ctaulic° victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS Style 009N i� r� .4°' ti Irl Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) Dimensions Pre-assembled Approx. Actual Maximum Maximum Allow. (Push On Condition) Joint Assembled Weight Nominal Outside Working End Pipe End Bolt/Nut e g Size Diameter Pressure 7 Load 7 Separation8 Size X Y X Y Z Each inches inches psi lbs. inches inches inches inches inches inches inches lbs. mm mm kPa N mm No. mm mm mm mm mm mm kg 11/4 1.660 365 790 0.102 %x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 M10 x 2 79 127 70 127 51 0.6 11/2 1.900 365 1035 0.102 %x 2 3.38 5.13 3.00 5.13 2.00 1.5 40 483 2517 4604 2.54 M10 x 2 86 130 76 130 51 0.7 2 2375 365 1616 0.122 %x2' 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 M10 x 21/2 102 143 89 143 51 0.9 21 2.875 365 2370 0.122 '/a x 2 i 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 M10 x 21/2 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 2 %x 21/2 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 M10 x 21/2 118 152 105 156 51 1.0 3 3500 365 3512 0.122 %x 21/2 5.13 6.75 4.63 6.75 2.00 23 80 88.9 2517 15622 3.05 M10 x 21h 130 171 117 171 51 1.0 4 4.500 365 5805 0.17 a/3 x 21/2 6.00 7.88 5.63 7.50 2.13 2.9 100 1143 2517 25822 4.32 2 M10 x 21/2 152 200 143 191 54 13 108.0mm 4.250 365 5175 0.17 2 %x 21h 5.63 7.38 538 738 2.13 3.1 108.0 2517 23020 432 M10 x 2'h 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.17i 2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 1413 2000 39456 4.32 M12 x 3 184 235 171 232 57 2.3 133.Omm 5.250 365 7897 0.17 2 ih x 3 6.63 9.00 638 9.00 2.25 4.8 133.0 2517 35106 4.32 M12 x 3 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 i x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 4.32 M12 x 3 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 2 i x 31/4 7.88 10.00 738 9.88 2.25 5.6 159.0 2517 49753 4.32 M12 x 31/4 200 254 187 251 57 2.5 6500 365 12105 0.17 1h x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 mm 165.1 2517 53813 4.32 2 M12 x 31/4 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 i x 31/4 838 10.38 7.88 10.13 2.25 6.0 150 168.3 2000 44469 4.32 2 M12 x 31/4 213 264 200 257 57 2.7 216.0 mm 8.500 365 20712 0.17 2 5/a x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 M16 x 4 270 337 260 257 67 5.2 8 8.625 365 21326 0.175 2 x 4 10.88 1338 10.25 13.13 250 11.4 200 219.1 1620 94863 4.32 M16 x 4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZTh1 couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZT""Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTm couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-SealTm gaskets are not compatible and cannot be used with the FireLock EZT"'couplings. • • 10.64 7072 Rev G Updated 10/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com4 ✓ataulic victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 6.0 REFERENCE MATERIALS Publication 05.01:Seal Selection Guide I-009N/009H:Installation Instructions FireLock EZTu Rigid Coupling • • User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to Installation alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions g'Reference should always be made to the I-009N/I-009H Firelock EZ Rigid Coupling of sale,installation guide,or this disclaimer. p' g Installation Instructions for the product you are installing.Handbooks are included with Intellectual Property Rights each shipment of Victaulic products,providing complete installation and assembly data, No statement contained herein concerning a possible or suggested use of any material, and are available in PDF format on our website at www.victaulic.com. product,service,or design is intended,or should be constructed,to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design,or as a recommendation for the use of such material,product,service,or design in the infringement of any patent or other intellectual Trademarks property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZT.,Flush-Sealr.,and Installation-ReadyT'"are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S.and/ countries. or other countries. • 10.64 7072 Rev G Updated 10/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 5 ✓Ctaulic" CARBON STEEL PIPE GROOVED COUPLINGS .. 0Pa6.08 Reducing Coupling co. FM V I � Or SEE LISTED PUBLICATION 10.01 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run.Designed 1 • to replace two couplings and a reducing fitting,the Style 750 features a special reducinglb WI gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. \\ice\\ (1�I1 1111 MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating:Orange enamel • Optional: Hot dipped galvanized and others Gasket:(Specify choice*): • Grade"E"EPDM(All other sizes) EPDM(Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. * Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized,carbon steel Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com jctaulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_J 06.08_1 CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling STYLE 750 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Approx. Size Pressure* Max.End Load* End Sep.t Deflect.Fr.Cit No-Size Dimensions-Inches/mm Wgt.Each Nominal Per Pipe Size psi Lbs. Cplg. In./Ft. Lbs. Inches/mm kPa N Inches/mm Deg. mm/m Inches X Y 1 Z kg 2 .20 338 528 1.88 2.7 0°-57' 2-3/8x2 50 k 25 € 2410 2225 0...1..8 17 85 134 48 1.2 11/2 , 350 1000 x 0 0.07 € r 0 20 3.38 528 1.88 2.0 0° 57 2 3/8 x 2 40 2410 4450 44 0 1.8 17 I 85 134 48 1.0 21/2 2 500 2215 f 0 007 016 ' 400 593 188 1 3.1 x 0 4T , 2-3/8x2 48 14 65 50 3450 9850 0 18 14 102 151 76.1 mm x 2 350 15500 0.07 -47' 0.16 438 663 1.88 46 50 2410 6900 0° 0-1.8 14 2-1/zx2s1 111 168 48 21 I 3 2 350 1550 4.75 7.13 1.88 4.9 80 x 50 2410 6900 0 1.8 0°-39 11 i 2 f x 2 3/a 121 181 1 48 2 2 ° 21/ 500 3250 i 0-0.07013 4 75 713 1.88 4.3 65 3450 14460 0 1.8 1 0 39 71 2 '/z x 2 a/a 121 181 48 2.0 88:9mm x 76.1 mm 350 i 2475 0-0.07 1 0._39' 0.13 "... 2-fix2sl 4.75 s 7.13 1.88. 4.2 2410 11010 0-1.8 11 121 " 181. .. 48y„ 1.9 4 2 350 1550 0-0.13 1. 19, a28 2-5/8 x 31/4 6.25 8.90 2.25 8.1 100 50 2410 6900 0 32 25 159 226 1 57 37 21/2 350 2275 i 0 013 0.28 625 1 19 2 5/8 x 3 fa a 850 2 25 8.6 65 2410 10125 0 32 1 25 , 159 226 57 3.9 3 500 4810 0-0.13 1a28 6.00 8.90 = 225 67 80 3450 I 21400 0-3.2 t 1°-19 2 5/8x3/a 25 152 226 57 3.0 114.3 mm x 76.1 mm 350 2475 0-0.13 1._19, 0 28 2-5/8 x 311 6.25 8.90 € 225 69 2410 11014 0 3.2 25 159 226 € 57 3.1 5 4 350 5565 0 0.13 i a22 1 , , 718 10.70 2.13 112 125 x 100 2410 1 24765 I 0 3.2 1 3 19 2 1 x 4/ 182 , 272 ` 54 51 64 350 5565 1 0 0.13 0 52 018 2 3/a x 41/48.63 11B0 225 16.7 150 x 100 2410 24765 0 32 15 181 302 57 76 5 350 8500 €' 0-0.13 f.. 0°-52' 0.18 ! 2-31x4fa 831 11.90 p 225 12.9 125 2410 37825 0 3.2 15 211 302 57 5.9 165.1 mm x 4 350 5565 0 0130.19 8.63 11.90 225 15.2 0 -55 1 2-ax4'/a 100 2410 24765 0 3.2 1 16 1 219 302 57 6.9 8 6 350 12060 E 0 0.13 1 0 38, 013 2 7/8x5 081 14.88 250 224 »» 200 x 150 2410 € 53645 0 3.24411 ? 275 378 64 10.2 350 11610 0-0.13 013 ° _,. 10.75 14.88 ` 2.50 _ 232 219.1 mm x f 165.1 mm 2410 ( 51645 0-3.2 0 38 11 ; 2-7/8 x 5 273 1 378 i 64 i 10.5 10 8 350 20450 0-0.131 0 .9 13.12 1726 ` 2.62 31.4 273 X 2191 2410 90970 0-3.2 0°-25' [ 8 S 2-1 x 5'/z 333 438 67 142 Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details. *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 14-3'f'/20-90 mm;25%for 4"/100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. Y r._�zi �Y +Z-► ) 9 _R•F., �J I .� of �� ✓ 1 j www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. uCY.aUIiC� 06.08_2 REV_J CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling STYLE 750 FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Pipe Size Length Size Length Nominal Nominal Size Sm.Dia. Size Sm.Dia. Inches/mm Feet/m Inches/mm Feet/m 2 1 '= 5.9 1 2 27 50 x 25 `! 1.825 x 50 08 11/2 20 11/2 2 1.9 40 0.6 40 x 50 0.6 21/2 x 2 1.9 22�/ 1.0 65 50 0.6 50 x 65 03 1.9 761mm x 1.0 0 0.6 76.1mm 03 3 2 ` 55 80 x 50--,,,,,l 1 7 80 1.1 21/2 I 3.8 4 3.0 651.2 100 0.9 889mm x 76.1 mm ; 3.8 2%: x 3 2.5 1.2 65 80 0.8 4 2 £ 6.0 4 3.0 100 x 50 1 1.8 100 0.9 21/2 1 6.0 76.1 mm x 88.9mm 2.5 65 a 1.8 0.8 3 60 1143mm1 3.0 80 1.8 ,.,.m 0.9 m. 1 114.3mm x 76.1 mm 6.0 3 x 4 i 2.5 1.8 80 100 0.8 , _v 5 4 3.0 4 5 3.3 125125 x 100 0 9 100 x 125 11.0 6 4 60 6 46 150 x 100 I 1.8 150 jW 14 .. 5 45 165.1mm1 46 125 14 14 4 60 5 6 r 23 1651 mm x 100 1.8 125 x 150 07 8 6,.v 73 . 6. . 8 60... I 200 x 150 22 150 x 200 1.8 2191 mm x 165.1 mm 73 1651 mm. x 2191 mm, 5.4 2.23 1.65 ''11 10 8 8.7 8 10 63 273 x 2191 2.65 2191 x 273 19.2 www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iL.'t'aulllc REV_J 06.08_3 CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV J UPDATED 08/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �ataUllc 06.08 Victaulic® Flexible Coupling 4tauiicr Style 75 06.05 • Victaulic RX roll sets must be used when grooving tow light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. VU Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or Exaggerated for clarity property damage. Approvals/Listings ® @' LPCB 0 Q (yds) NOTICE • Victaulic RX grooving rolls must be ordered See Victaulic publication 10.01 for details separately.They are identified by a silver color and See Victaulic publication 02.06 for portable water approvals if applicable. the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77,the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or"T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade"EHP" or"T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads.When used on light wall stainless steel pipe,the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. 1ictauIid victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Bolts/Nuts: Ductile iron conforming to ASTM A-536,grade 65-45-12. Heat-treated plated carbon steel, trackhead meeting the Ductile iron conforming to ASTM A-395,grade 65-45-15, physical and chemical requirements of ASTM A-449 and is available upon special request. physical requirements of ASTM A-183 Housing Coating:(specify choice) ❑ Standard: Orange enamel. ❑ Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE:Additional gasket styles are available.Contact Victaulic for details. ❑ Grade"E"EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. ❑ Grade"T"Nitrile Nitrile(Orange stripe color code). Temperature range 20°F to+180°F/29°C to+82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 iCtaulie victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 I~Y-'I rZ" r:.��1 r.. MI 1 I :I: iii Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation' Centerline' Bolt/Nut4 X Y Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/m (No.)size inches mm mm mm kg 1 1.315 500 680 0-0.0620-43' 0.57 2-'/s x 2 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 11/4 1.660 500 1080 0-0.060.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 2°-10 38 2-'/a x 2 68 117 45 0.6 1% 1.900 500 1420 0-0.061.-56' 0.40 2-'/s x 2 2.91 4.82 1.77 1.5 40 483 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2215 0-0.060.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1°-31 26 2-'/a x 2 87 133 48 0.8 2'h 2.875 500 3245 0-0.06 °_ 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1 15 22 2-1,8)(2 98 144 48 0.9 3.000 500 3535 0-0.060.26 4.00 5.90 1.88 1.9 76.1 mm 76.1 3450 15730 0-1.6 1.-12' 22 2-'/e x 2 102 150 48 0.9 3 3.500 500 4800 0-0.060.22 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 1°-2 18 2-1/4 x 2'/a 114 178 48 13 3 YZ 4.000 500 6300 0-0.060.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 54' 76 2-�k x 23/4127 191 48 13 4 4500 500 7950 0-0.1310-36' 0.34 2-'/z x 2'/a 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 4.250 450 6380 0-0.13 0.35 5.55 7.79 2.13 3.7 108.0 mm 108.0 3100 28395 0-3.2 1°-41 29 2-12 x 70 141 198 54 1.7 41/4 5.000 450 8820 0-0.130.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1°-26 21 2-5/e x 3'/a 156 240 54 2.5 5 5.563 450 10935 0-0.130.27 6.88 10.07 2.13 5.8 125 1413 3100 48660 0-3.2 1°-18 23 2-5/ax3'/a 175 256 54 2.6 5.250 450 9735 0-0.13 10-21' 0.28 2_16 x 82.5 6.55 9.37 2.13 6.0 133.0 mm 133.0 3100 43325 0-32 24 166 238 54 2.7 5.500 450 10665 0-0.13 1°_18, 0.28 2_s�x 3,/, 6.80 9.59 2.13 63 139.7 mm 139.7 3100 47460 0-3.2 24 173 244 54 2.9 6.000 450 12735 0-0.13 1°-12' 0.21 2-5/a x 3'A738 10.48 1.88 6.2 152.4 mm 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.131.-5' 0.23 2_s/e x 3'/a 8.00 11.07 2.13 7.0 150 1683 3100 69085 0-3.2 18 203 281 54 3.2 6.250 450 13800 0-0.13 10-9' 0.24 2-16 x 82.5 7.63 10.49 2.13 6.8 159.0 mm 159.0 3100 61405 0-32 20 194 266 54 3.1 8 8.625 450 26280 0-0.130°_50' 0.18 2_;/a x 4'/a 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for Y4-3 5"/20-90 mm;25%for 4"/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictauliC° • victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulic Ai'l BilB' JY ® SIDEWINDER° FOR WOOD -Horizontal Application Application Product Features Not less than 2"nominal width / No pre-drilling required. (1-1/2")up to 3.1/2"pipe;not less than _ 3"(2-1/2")nominal width 4"&5"pipe 21 •Quick to install using the Sammy sr a,Wwe.Iw�1f� b�—f I-1 Floor Joist Nut Driver with an 18V cordless Minimum 2-1/2"from bottom for drill/driver. branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional W requirement shall not apply to 2"or methods. thicker nailing strips resting on top of Ili steel beams. •Reduces installation costs. Cl) ,, •Made in the U.S.A. I Composite/Truss r Consult buss no Jl.cture•for e ornrr tl d r tot of point. Pre Ilir roar r qo r d for Model S,.G L,,3& Too avai'0bl on age 11. 3S 3; B � Watch a video demonstration at J ' www.ilwbuildex.com 1 111 Rod Part Screw Ultimate UL Test Box Case Cl)IApprovals Size Number Model Descriptions Pullout(lbs) Load(lbs) Qty Qty + HORIZONTAL MOUNT 1/4" 8019957 SWG 200 1/4 x 2" 1725(Fir) 25 125 . ':Afe xf."X�11e4z. 4..f ., . f. " 't4if.r ..v.822*4- :'' ,P'..:•303;. 1' i„', ,' 3/8" 8021957 SWG 20 1/4 x 2" 1725(Fir) 1050 25 125 — l`r ' 3/8' _; „Ter* , c 5S. , . 1', ";.`a .25, 1251,. Q. 3/8 8022925 SING 25-380 3/8x2-1/2" 2249(Fir) 1500 25 125 #14 SW Red _ �11 .:-`;y°too,,,,,:,';., ....•;,,,`,`,.., _" ' . , '' F ,,,...,-A, ..'25, 125. W Nut Driver11,� Part#8114910 •May require pre-dnlling;consult joist manufacturer. LU Ct SAMMYS SWIVEL HEADTM FOR WOOD -Swivel Application v Application Product Features O V WOO JOST • Kean •Eliminates distortion of threaded rod. se•osT . •Accommodates up to 3 Y2"x 12 pitch roof. •Allows 17°deflection from vertical. Cl) •Saves time from traditional methods. W I saw e •Reduces installation costs. CC �r wauw�es •Made in the U.S.A. 0 vo' Cl) Rod Part Screw Ultimate UL Test Load FM Test Min Box Case Approvals Model W Size Number Descriptions Pullout(lbs) (lbs) Load(lbs) Thickness Qty Qty SWIVEL MOUNT V� #14 Black t.Q 3/8 8139957 SH GST 20 1/4 x 2" 1257(Fir) 1050 1475 25 125 V I Nut Drivep.r Q Part#8113910 Y 318`'. 1 „rm...., ti-0.0 �f4 X 3 1720), :Eif10" :.: '1475' e y. 1903 Dim.Lumber 1500 iQ. 3/8"` 8269957 SH-GST/CST 20 5/16 x 1.3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 Dim.Lumber Cl) ,g11-j''''''': 1/2 8 r 57 SH-GST/CST 2.0 c t 3/4 "m.C .ff vedieat ,,,, °e71' Y1�25 i t ., s . s " r May require predrilling;consultjoist manufacturer. 0 #14 SH Orange Nut Driver t Part#8273910 a. IX Q 5 To find a distributor near you.call 800-BUILDEX E 'dsaoti, ..if E SAMMYS® FOR WOOD - Vertical Application Application Product Features Not less than Wood Fluorin 2"nominal width s •No pre-drilling required. (t/")/ •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3'nominal drill/driver. thickness(2-1/2") (depth or side Wood Joist 1fvedicsl member) cum •Saves time from traditional its methods. Double Sheetrock F.c"venc��a Ceilinra •Reduces installation costs. hslal in cer ler o er`ace. i '^lnlr urn 2T er76e, into base '' •Mad@ in the U.S.A. matenaI for NF?/a 13 oonipIiance, <' Composite/Truss , z v iltlo �arc(aC 'or(or I rrr u e l n a ln_o,point 'Fred �mayb r.quucd for GST 1? ' 253 irf Watch a video demonstration at Tart,' www.ifwbuildex.com Approvals Rod Part Model Screw Ultimate UL Test FM Test Box Case Size Number Descriptions Pullout(lbs) Load(lbs) Load(lbs) Qty Qty VERTICAL MOUNT 114" 8t0.0102957 GST 100 1/4 x 1" 210 (7116'OSB) 25 125 ^� /�f 14,11; ) �] 670 (3/4"Ply) J'''''';''''-'''I'", 14 :�+ 6 ! 'f QST OO umr,. £}r4 t<�' � *C A ii.: pY ,:: �. �5 125 a 114 8004957 GST 300 l/4 x 3 2060(Fir) 25 125 r / ADO 1it tr ? e g Syr 925 - I Y`' 3/8 8008957 GST 20 1/4 x 2 1760 (Fir) 850 :,,., : 1475 25 125 ' .,-, `, ? Go,J l',,,/4 . e ;tea ..:;,- _<' "Q. 3/8 8009925 GST 25-3 80 3/8x2-1/2" 2113(Fir) 1500 25 12b #14 Black Q`<� .,...# 'i1r 7.., T� 14� w Vii.. < i�,..r�. b " � " Nut Driver 3/8 t 80 8069925 GST 30 SS 'I/.4x,,--23"1 /4 x 3 2060 l*r(Fir) 25 125 Part#8113910 s,- z t. 1/2' 8013925 GST 2 1/4 x 2 1760 (Fir) 25 125 > <"2a . 12 r 8994925. °f / " r L`;x2'il ,% 43< ;f'ill .r: n. ..•,. <, �a < 1 5.Af i -t- 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 t ,c :; - y5 MADE IN U.S.A SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 4 . 47. 71g10,0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 514 CPVC - COPPER .905 #906 STEEL ER41004OFFSET HANG 31.1 ,p1 ... ..r SIZE-SYSTEM PIPE: 3/4"thru 2" O MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- Hanger/Restrainer `Oas pus203-EX 4231,EX 2551 �I■� PATENT-No.6,648,278. 1.101111%FUNCTION- Support horizontal piping: CPVC,Copper or Steel. Provides listed vertical/horizontal restraint and prevents upward movement of pipe from pendent sprinkler discharge. Hanger/ � I � Stabilize vertical piping. INSTALLATION- Per these instructions Restrainer '`= Stabilize including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. Snap over pipe then squeeze strap back allowing pipe to slide freely. 1611 When #905 threads are exposed in wood,install#906 backing nut. --. FASTENERS-UL Listed per NFPA 13 `IJ) WOOD- CPVC pipe-#905 screw-no pre-drill. Copper and Steel pipe-#14 SMS or 1/4"xl 1/2"lag screw- no pre-drill. Thru 5/8"gypsum board- 1/4"x 2"lag screw. STEEL-min. 18 GA.-CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. • o CONCRETE:Required minimum load each fastener= 5(wt)+2501bs. 2 4 4 FEATURESo * 1 1/2"Offset-loose fit allows pipe to slide. v, 4 *Common center-line for 3/4"and 1". *Offset edge eliminates abrasion. *AFCON#905 screw included-5/16"hex head. n ORDERING-Part#and pipe size. ,v AFCON#906 backing nut sold separately. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners,resulting m a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. 11/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 515 CPVC DOUBLE OFFSET HANGER Hanger/Restrainer MEW e 0 SIZE-SYSTEM PIPE:3/4"and 1" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- 0`„�a"203-EX 4231 PATENT-No.6,702,236 FUNCTION-Support horizontal CPVC pipe. Provides listed vertical/horizontal restraint and prevents Hanger/Restrainer upward movement of pipe from pendent sprinkler discharge. INSTALLATION- Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS-UL Listed per NFPA 13. #904 screw in wood-no pre-drill. FEATURES ^\ *Double 1 1/2"offset (�,�//] *Common center-line for 3/4"and 1". *Offset edge eliminates abrasion. *Required AFCON#904 screw included-3/8"hex head. ORDERING-Part#and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non AFCONproducts have been,or are used. CAD 11/13 . 7. 71g§, DI P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 510 CPVC - COPPER - STEEL HANGER 510 Fastener ----(Q SIZE 2.125 3/4 2.125 1 2.312 Q 1 1/4 3.170 1 1/2 3.400 2 4.010 ® 2 1/2 4.320 3 5.320 SIZE-SYSTEM PIPE:3/4"thru 3" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- r `®us 203-EX 4231,EX 2551 FUNCTION-Support horizontal piping: CPVC,Copper or Steel. Size 3/4"-2"Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. i A INSTALLATION- Per these instructions MIS u INN including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3/4"-3"CPVC pipe-#905 screw-no pre-drill. 3/4"-3"Steel and Copper pipe-#14 x 1 1/2"SMS or Restraint 1/4"x11/2"lag bolt-no pre-drill. in STEEL-min. 18 GA. ` I r—\ 3/4"-3"CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. (� 1:::) :::) FEATURES *Offset edge eliminates abrasion. *Retainer dimples secure hanger to pipe during installation. Hanger Irip *Required AFCON#905 screw included-5/16"hex head. r,;� Stabilize ORDERING-Part#and pipe size. 1 1 CAN ALSO BE USED TO REPLACE-#500 Pipe Strap —2-- #520 Tin Strap Specific AFCON products are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners,resulting m a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used m combination with other products,parts or systems not manufactured or sold by AFCON AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. 'r 5/14 . 77: jrg1012 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 300 RING HANGER P. I I 1 thru 4 Inch pipe 1/2&3/4 Inch pipe LISTED FOR STEELJCPVC 5 thru 8 inch pipe NFPA 13 UL 1 WT. 5 WT.+250 TEST PIPE ROD LOAD 1 3/8 30.75 403.75 750 11/4 3/8 43.95 469.75 750 1 1/2 3/8 54.15 520.75 750 SIZE-ROD-3/8"or 1/2" 2 3/8 76.95 634.75 750 SIZE-SYSTEM PIPE- 1/2"thru 8" 21/2 3/8 118.35 641.75 850 MATERIAL-Carbon Steel,Mil.Galvanized to G-90 spec. 3 3/8 162.30 1061.50 1050 LISTING/APPROVAL- 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 CQUS O 203-EX 2551 1"-8" 6 1/2 476.35 2631.75 2650 FM Approval guide-1"-8" 8 1/2 711.00 3805.00 4050 OSHPD OPA-0601 See Website. CONFORMS WITH:Federal Specification WW-H-171E,Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe hanger component of an AFCON hanger. To support steel,CPVC or copper pipe. INSTALLATION-Per NFPA 13, 13R, 13D,these instructions and PIPE A B pp . the CPVC or copper pipe manufacturers instructions. 1 1 8793 2.5259 FEATURES- 11/4 2.1382 2.7850 * 673 Sized and listed exclusively for use with#310 Surge Restrainer. TT 1 21/2 22 3.252.9140+6 * Band edge is offset for EASY pipe insertion. A 2,/2 3.4926 4.++50 * Custom fit swivel nut for better retention in ring. 3 3.7845 4.4311 ORDERING-Part#,pipe size. I 4 4.3=82 4.9992 6 6.0668 6.8+80 • 8 7.5768 8.3290 riS n �+ d#' CAD 11/09 . 7,/ 70 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32" 17/32" O*11-1101 e *1.•1\� ,„$ 077D DUCTILE BASE PLATE 077S STEEL BASE PLATE SIZE-BRACE PIPE: 1"and 1 1/4"Sch.40 MATERIAL-Carbon Steel,Ductile Iron or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- 0's 203A-EX2625 Q FM Approved-1950 OSHPD See Website. USTED FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. cOus Max. Horizontal Load WEI Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Size 1-1 1/4 2015 INSTALLATION-Per these instructions including NFPA 13 or FM 2-8. Load rating-see chart. ASSEMBLY Combine with proper AFCON components-see disclaimer below. Insert brace pipe thru fitting near pivot bolt. FM Tighten set bolt until head contacts bracket. Max.Horizontal Load FEATURES 30-44° 45-59°60-74°75-90° *Swivel allows attachment at any angle. *Visual inspection,verifies proper installation. Size 1-1 1/4 630 870 1620 1810 *Larger fastener hole available.-Consult factory. ORDERING-Part#,size-brace pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting m a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 9/14 CAD .. 7v:Z?Ig P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 411 SWAY BRACE FITTING Part# Pt% 077 V� Part#078 / Gln, 077 / / SIZE-SYSTEM PIPE:Nominal Pipe Size "�11 *, .40 // Sch.40 Steel 1"-12" Sch. 10 Steel 1 1/4"- 12" Sch.7 Steel 2"-6" MATERIAL-Carbon Steel or S.S.(Type 304) FINISH-Plain or E.G. PATENT-No.7,140,579 ®Listed Max.Horizontal Load LISTING/APPROVAL 1"-10" 2765 c �L us12" 3740 203A-EX 2625 ® FM Approved-1950 FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with ©Certified Max.ASD Horizontal Load NFPA 13 and the manufacturer's installation instructions. INSTALLATION- Per these instructions systemNPs Sch. 30°44° 45°-59° 60°-74° 75°-90° including NFPA 13 or FM 2-8 1"-1 1/2" 10-40 _420 510 570 2"-3" 7-40 860 1030 1150 Load rating-see chart. 4" 7-40 860 1030 1150 ASSEMBLY-See drawing. 5" 7-40 950 1150 1280 Combine withro er AFCON components-see disclaimer below. 6" 7-40 2220 2220 3040 p P 8" 10-40 1340 1620 1810 Align brace member parallel to face of 411 fastener flanges. Tighten 1/2"bolts until fastener flanges connect. FEATURES * Patented-design eliminates bending of fastener flanges during installation. * Patented-design prevents over tightening on system pipe. * Improved assembly-fastener flanges connect for superior strength. * Visual inspection-proper installation when 411 fastener flanges connect. ORDERING-Part#,size-system pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. CAD 5/14 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 078 ATTACHMENT FITTING LOCKING 9/16 Dia. Part# tio t•,46 ,Fart#078 I 0 Part#410/411— SIZE-BRACE PIPE: 1"and 1 1/4"Sch.40 MATERIAL-Carbon Steel or S.S.(Type 304). -11 FINISH-Plain or E.G. LISTING/APPROVAL- 0* 203A-EX 2625 <> FM Approved-1950 OSHPD See Website. FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. Common transition component with 411 sway brace fitting-see drawing Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION- Per these instructions including NFPA 13 or FM 2-8. 0 Max. Horizontal Load Load rating-see chart. DO NOT BEND-If angle required use part 070,075,076 or 077. 30°-44° 450-59° 60°-89° 90° ASSEMBLY 1008 1425 1745 2015 Combine with proper AFCON components-see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. Fa Max. Horizontal Load FEATURES 30°-44° 450-59° 60°-74° 75°-90° *Visual inspection,verifies proper installation. 430 620 760 940 *Bolt hole fits 410/411 sway brace fitting. ORDERING-Part#,size-brace pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. s '4 4/14 • P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 400 RISER CLAMP IRON PIPE PIPE STOCK MAX.REC.r— C �--+ C—01 SIZE A B C SIZE LOAD LBS. i ( T 1 1/2" 10 3/8" 3/8" 1 1/2" 3/16"x1 1/4" 255 2" 10 3/4" 3/8" 2" 3/16"x1 1/4" 255 1 am Ise o o 2 1/2" 11" 3/8" 2 1/8" 1/4"x1 1/4" 390 1a1 1st 3" 12" 3/8" 3 1/4"x11/4" 530 3 1/2" 13" 1/2" 3 5/16" 1/45(1 1/4" 670 B B 4" 13 1/2" 1/2" 3 3/8" 1/4"x1 1/4" 810 5" 14 1/2" 1/2" 4" 1/4"x1 1/2" 1160 6" 15 1/8" 1/2" 4 1/2" 1/45(2" 1570 8" 18 1/2" 5/8" 5 13/16" 318x2" 2500 NOTE:MAXIMUM TEMPERATURE:650°F SIZE- 1/2 thru 20 inch pipe. �, $1 MATERIAL-Carbon Steel. FINISH-P1aigG.,H.D.G.and S.S. LISTING/APPROVAL- EX 2551 11/2"-8"pipe. OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E,type 8,3/4 thru 20 inch,and Manufacturers Standardization Society SP-69,type 8. FUNCTION-Used for supporting vertical piping. ORDERING-Part#,pipe size and finish. 1/08 IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS 10.96 FireLock® Zone Control Riser Module ® p <> SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 747M Designed for NFPA 13 commercial requirements,the Victaulic Series 747M Zone Control RiserG Module features a cast body,and is compact and easy to install in zoned wet sprinkler systems. The integrated module body consists of a shut off valve,test and drain valve combination and different orifice sizes(K factors),a UL Listed and FM Approved Flow Switch,and a Pressure Gauge.The Series 747M FireLock Zone Control Riser Module is available in sizes from 11/4 through 6'/32 mm-150mm with grooved ends on the main pipe for installation in the horizontal or vertical up-flow positions with UL Listed,FM Approved Victaulic grooved couplings.1'/4-2"modules have an NPT drain port.2' -6'modules have a grooved drain port. The Series 747M FireLock Zone Control Riser Module is FM Approved and UL and ULC Listed for working pressures up to 365psi/2517 kPa.An optional pressure relief valve kit is available STYLE 747M for all sizes.The Pressure Relief Valve is FM Approved and UL and ULC Listed for working PATENT PENDING pressures up to 175psi/120OkPa. Aprx.Weight DIMENSIONS Dimensions Inches/mm Each Module Body Size 4,V(gol ,, , ., ., 5 . . . > ,, ., , `'minina Tam a Iii (a MMheMMf.. , . . 11/4 1.660 1 11.45 7.20 5.77 3.50 , 10.05 7.48 slh,2.54 15.2 T U i 32 I 42.2 33.4 1 290.8 1 182.9 " 146.5 88.9 255.3 l 190.0 64.5 6.9 ' '`' C 1' 1900 1 11.45 7.32 , 5.77 350 10.05 7.48 2.54 i 15.5 1 `r w. I F 40 s 48.3 I 33.4 1 290.8 185.9 " 146.5 i 88.9 , 255.3 190.0 64.5 7.0 _.37 .., .. L 2 i 2.375 1 11.45 7.55 5.77 1 3.50 10.05 7.48 2.54 19.9 50 60.3 ` 33.4 290.8 a 191.8 : 146.5 ' 88.9 , 255.3 190.0 1 64.5 9.0 2 1/2 2.875 1 1/4 . 12.00 € 8.41 6.18 , 4.25 9.76 11.87 I 4.25 22.7 E G 65 _mmm 73.0 42 305 mm r 214 .. . 157 4_108 ' 248 302 108 "i" 103 A 3 ` 3.500 11/4 i 12.00 ` 9.42 6.18 4.25 i 9.76 . 11.87 i 4.25 232 80 j 88.9 42 , 305 239 . 157 ; 108 248 , 302108 10.6 -- 11/4-2"/32-50mm Nominal Sizes • ""„"' "'""" '. "" "`""" 4 4.500 , 2 12.00 9.90 725 5.00 1 10.15 I 12.62 4.21 i 30.3 } 100 I 114.3 60 1 305 252 184 11. 127 258 321 107 13.8 - - a 4 6 6.625 2 i 12.00 10.85 ' 8.31 C 6.00 10.15 ,13.62 4 24 36.7 /10 150 168.3 60 305 276 . 211 154 258 346 „ 107.7 16.7 B III. Orifices 1 pt q.. 5 R llI 7 Nominal Size I _ inches D la'ill G 1.25 K5.6 �- NI � ,Jw_. 1.5 K5.6 7.7`ces K5.6 F I' 1 2 ( ( 25 K5.6 K6.9 K8.0 K11.2 1 I 3 K5.6 K6.9 K8.0 K11.2 E 1 1 - 4 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 6 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 A 21 -6"/65.0-150 mm Nominal Sizes Drain Size Nominal Size Drain Type (Valves shown above in the"test"position. inches Shown with optional Pressure Relief Valve Kit /-_.. -... 1 __ __... in-ta"WNPT ) 1.25 _.. ' Hose Clamp 1.5 ,. m._ ... NPT 1 NPT 25 Grooved Pressure Relief Valve 3 Grooved 1�4 "` "` Grooved Barbed Fitting Hose Clamp 6 Grooved i Close Nipple AO____ .."----Drain Tubing Elbow Barbed Fitting Optional Pressure Relief Valve Kit Detail JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com '�Ctaullic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV_I 10.96_1 FIRE PROTECTION PRODUCTS—DEVICES 10.96 FireLock® Zone Control Riser Module SERIES 747M MATERIAL SPECIFICATIONS Module Body:Cast from ductile iron conforming to ASTM A-536,grade 65-45-12 with integral Victaulic grooved ends.Finish:orange enamel. Shut-off and Test/Drain Valve:Chrome plated brass ball,S 37700 brass clapper,416SS or 410SS shafts,Delrin orifice,virgin Teflon*,enhanced Teflon and EPDM rubber seals. *Teflon is a registered trademark of Dupont Coupling:Any UL Listed,FM Approved Victaulic IPS-sized coupling may also be used.Note: Couplings not included with product. Waterflow Detector:System Sensor Model WFD/WFDTH vane type waterflow detector with sealed retard,visual switch activation,and mechanical delay adjustment.Cover includes tamper resistant security screws and tool.Note:ULC models WFDA/WFDTHA include cover tamper switch. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. WARNING rte- u, x • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage,or valve leakage. If you need additional copies of this product literature or the valve installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company,P.O. Box 31,Easton,PA 18044-0031 USA,Telephone:001-610-559-3300. For complete contact information,visit www.victaulic.com 10.96 3089 REV I UPDATED 7/2010 ictaUl1Cr VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.m 2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.96 FireLock® Check Valves ✓ctaulic Series 717 & 717H 10.08 Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted . +^ • to flanged (ANSI CL.150)equipment using either to Victaulic Style 741 Vic Flange®or Style 744 FireLock flange adapters on either end. Series 717 Series 717 (21 -3'/65-80 mm) (4-12'/100-300 mm) vn , IP Mt Series 717H High Pressure Check Valve (2-3'/50-80 mm) Approvals/Listings: gOUS FM VdS LPCB) LORD See Victaulic Publication 10.01 for more details. The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD designed for hydrodynamic efficiency and available in 2'/50 mm-3'/80 mm (Series 717H)and 2 1/2"/65 mm-12"/300 mm (Series 717)sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs,the single-disc mechanism incorporates a spring-assisted feature for nonslamming operation. This spring-assisted,single-disc design achieves a leak-free seal with as little as 5ft/1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically(flow upwards only)or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date Check Valve I Firelock®I Series 717&717H I Publication 10.08 ✓ctaul�c victaulic.com 1 Check Valve I Firelock'I Series 717&717H I Publication 10.08 Material Specifications: Spring:All sizes Type 302/403 Stainless Steel Housing: Shaft Plug: Ductile iron conforming to ASTM A-536, grade • Series 717H (2—3"/50—80 mm):Type 416 Stainless 65-45-12. Ductile iron conforming to ASTM A-395, Steel grade 65-45-15, is available upon special request. • Series 717 (2 1/2—12765—300 mm): Carbon steel zinc plated Body Coating: Series 717H Body: Black Paint Pipe Plug: Series 717H Endface: Electroless Nickel • Series 717H (2—3"/50—80 mm): carbon steel zinc Series 717 (2 1—3"): PPS Coating plated Series 717(4—12"): Black Paint • Series 717 (4— 127100—300 mm): Carbon steel zinc Body Seat: plated Series 717H—Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (2 'h—3"): PPS Coated ductile iron Series 717(4—12"): Electroless Nickel plated Disc Seal or Coating:(specify choice') ❑ Grade "T" nitrile(Series 717H Only) Nitrile(Orange color code).Temperature range—20°F to +180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. ❑ Grade "E" EPDM (Series 717 Only) EPDM(green color code).Temperature range-30°F to +230°F/-34°C to+110°C.Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3"/50—80 mm): CF8M Cast Stainless Steel • Series 717(2 1—3"): Aluminum bronze with elastomer seal • Series 717(4—12"/100—300 mm): Elastomer encapsulated disc with electroless nickel plated seat Shaft: • Series 717H (2—3"/50-80 mm): Brass • Series 717(2 V2—3"): Type 416 Stainless Steel • Series 717 (4—12"/100—300 mm)Type 316 Stainless Steel victaulic.com 2 ✓ataulic" Check Valve I Firelock®I Series 717&717H I Publication 10.08 Approval/Listing: ApprovalListing Service Pressures Series 717H Size cULus FM LPCB Vds 2"/50 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 2%765 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 76.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 3"/80 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 4"/100 mm n/a n/a n/a n/a 5"/125 mm n/a n/a n/a n/a 139.7 mm n/a n/a n/a n/a 6/150 mm n/a n/a n/a n/a 165.1 mm n/a n/a n/a n/a 8"/200 mm n/a n/a n/a n/a 10"/250 mm n/a n/a n/a n/a 12'/300 mm n/a n/a n/a n/a Approval/Listing Service Pressures Series 717 Size cULus FM LPCB Vds 2"/50 mm n/a n/a n/a n/a 2 1/2965 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 3"/80 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517kPa up to l6bar/232 psi 4"/100 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 5"/125 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 139.7 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 6'/150 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 165.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 8"/200 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi 10"/250 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a 12"/300 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a victaulic.com 3 ✓ctaulic Check Valve I Firelock!I Series 717&717H I Publication 10.08 Dimensions-Series 717: .s A -0 R N- blii. fire N D E • PL.II II C ,.._A_..., B k-K-N (a I K t�i I fl B -lJ B -►.J:4- III',II O' O co Yz"NPT Upstream Drain l OW NPT Upstream Drain h"NPT Downstream Drain ®W NPT Downstream Drain 0 2"NPT(Drain Optional) Typical 2 1-3765-80 mm Typical 4-8"/100-200 mm Typical 10-127250-300 mm Actual Dimensions Approx. Nominal Outside E to E Weight Size Diameter A B C D E J K P R Each inches inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm mm kg 21/2 2.875 3.88 4.26 3.57 3.6 65 73.0 99 108 91 - - - 1.6 3.000 3.88 4.26 3.57 - _ 3.6 76.1 mm 76.1 99 108 91 - - 1.6 3 3.500 4.25 5.06 4.174.5 80 88.9 108 129 106 - - - - 2.0 4 4500 9.63 6.00 3.88 2.75 350 2.00 4.50 3.50 3.35 20.0 100 114.3 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 _ 4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 123 139.7 mm 5.500 10.50 6.80 4.50 - 4.17 2.15 5.88 4.08 3.98 27.0 139.7 267 173 114 106 55 149 104 101 12.3 6 6.625 11.50 8.00 5.00 _ 4.50 2.38 6.67 4.73 3.89 38.0 150 168.3 292 203 127 114 61 169 120 99 17.2 165.1 mm 6.500 11.50 8.00 5.00 - 450 2.38 6.67 4.73 3.89 38.0 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 _ 100.0 250 273.0 432 305 180 151 170 55 277 171 45.4 12 12.750 19.50 14.00 8.06 6.91 7.64 2.51 12.81 7.73 _ 140.0 300 323.9 495 356 205 176 194 64 925 196 63.5 Dimensions-Series 717H: A ._B_--. Illk IkjI , 0 R J Typical 2750 mm-3780 mm Dimensions Approx. Nominal E to E Weight Size A B C D E J K P R Each inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm kg 2 8.66 6.46 3.23 1.48 3.02 2.80 _ _ 4.25 10.7 50 219.8 164.1 82.1 37.5 76.7 71.0 108.0 4.9 21/2 9.37 6.94 3.31 1.66 3.40 3.38 _ - 4.38 13.8 65 238.0 176.3 84.1 42.2 86.4 85.9 111.3 6.3 76.1 mm 9.37 6.94 3.31 1.66 3.40 3.38 - - 4.38 13.8 238.0 1763 84.1 42.2 86.4 85.9 111.3 6.3 3 9.62 7.44 3.53 1.91 3.65 3.38 _ _ 4.63 20.0 80 244.3 189.0 89.7 485 92.7 85.9 117.6 9.1 victaulic.com 4 ✓ctaulic Check Valve I Firelock®I Series 717&717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. S717H/717HR 10 � t °: a r � I 0.1 I -._.w ._. .L.._ _,_ .n.,.._ t_ L; ; 1 ,... ;..., 10 100 1000 Flow—GPM S717H/717HR 100.00 w 4444 p i 1 ,1. F ¢ Y 1 -. I \ i F F #6 I # i 6F €\ $ gt .b r F of F r J 10.00 I a tiF � $ ,, I.1<i. d 1.. 1„_. A h 1� y .. N O. ., . . s t i r i _ 411 x_ uw. i r, t I t i z i i I$ I 1.00 .. I. Y• „• 10 100 10o -. b0 10000 100000 Flow Rate—Litres/min. victaulic.com 5 ✓ctaulic Check Valve I Firelock®I Series 717&717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. S717/717R , I - - . .,� q1 g� 1 1F a „f FF $ 0� .,, Ie I 1 1 Iib y1 °�� 1 , rr ;v 1 I ;.1 Irl 1 1 _ . i 1 I I £ 1 ! 1 1k 0. 1 se. 10 100 1000 10000 100000 Flow-GPM S717/717R 10 . I i I .a r I 1b` F FF .2? 1b t Fr Fes, i ? 1..F. . g e, of y�c �) t,a ti H __ 11._. ,.. ... " . 4 - id H uuxw r ` tI i B ; 10 100 1000 10000 100000 Flow-GPM Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and FireLock are registered trademarks of Victaulic Company. 10.08 1479 Rev.R Updated 05/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 ictaulic FireLock® Buterfly Valve ✓ctaul;c Style 705 with Weatherproof Actuator 10.81 Material Specifications: _ ;, ,i Body: Ductile iron conforming to ASTM A-536,grade 65-45-12 End Face, 2—6750— 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8— 12"/200—300 mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Approvals/Listings: Coating: Black alkyd enamel 'VdS' �LPCB c 4� us FM Disc: Ductile iron conforming to ASTM A-536, grade OSTEO #G410001 104j/04 65-45-12,with electroless nickel coating conforming to See Victaulic Publication 10.01 for more details. ASTM B-733 Seat: Product Description: ❑ Grade "E" EPDM The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems:416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed for fire protection services only.Victaulic FireLock Stem Seal Cartridge: C36000 brass Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Bearings: Stainless Steel with TFE lining Contact Victaulic for details of agency approvals. Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: ❑ 2—8"/50—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10—12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer • System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 0 2014 Victaulic Company.All rights reserved. 1 jctaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2"/50 mm up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 2 1/2"/65 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3"/80 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 47100 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6'/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8"/200 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 iCtauliC victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Dimensions: IMTIMINO M•V OH 1 rjimilill MII F -lam G E-.---A -D NOTE:OPTIONAL'rz"/15MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. Actual Dimensions Nominal Outside E to E Size Diameter A B C D E F G DIA H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2375 4.25 2.28 6.41 _ - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 2'/2 2.875 3.77 2.28 7.54 _ _ 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 1915 101.6 107.2 1143 45.0 76.1 mm 3.000 3.77 2.28 7.54 _ - 4.00 4.22 450 1.77 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 _ _ 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 1143 1072 114.3 45.0 108 mm 4.250 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 _ _ 550 422 450 220 114.3 1143 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 335 10.88 - 656 6.19 6.30 258 133 mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 139.7mm 5.500 5.88 3.35 10.88 - _ 6.56 6.19 6.30 2.58 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 _ _ 656 6.19 630 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 655 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 630 258 159 mm 159.0 149.4 975 289.1 10.4 191.0 157.2 160.0 655 165.7 mm 6.500 5.88 3.84 11.38 - 0.41 752 6.19 6.30 258 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 _ 0.41 752 6.19 6.30 1.90 1683 168.3 149.4 975 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 233 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 637 15.64 1.41 1.81 12.25 8.10 9.00 _ 273 273.0 162.6 161.8 397.3 35.8 46.0 311/ 205.7 228.6 12 12.750 650 7.36 16.64 230 2.80 1425 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 SO 60.3 1.8 21/4 2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulic' victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: Cv values for flow of water at+60°F/+16°C through a fully open valve are shown in the table below. For additional details,contact Victaulic. Formulas for C,values Formulas for K,values Where: �F=Q2/IS,s Where: AR=Q2/cv2 Flow Coefficient C, Q=K X VAP Flow Factor ILI Q=C xVAP Q(Flow) BEI Q(Flow) AP(Pressure Drop) psi AP(Pressure) bar Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches C„ inches inches I(, mm mm mm mm 2 2375 2 2.375 147 50 60.3 170 50 60.3 21/2 2.875 2' 2.875 225 65 73.0 260 65 73.0 76.1 mm 3.000 260 76.1 mm 3.000 225 76.1 76.1 3 3.500 440 3 3.500 380 80 88.9 80 88.9 4 4.500 820 4 4.500 710 100 1143 100 114.3 108mm 108mm 820 108mm 108mm 710 5 5.563 1200 5 5.563 1040 125 1413 125 1413 133mm 133mm 1200 133mm 133mm 1040 139.7 mm 5.500 1200 139.7 mm 5.500 1040 139.7 139.7 6 6.625 1800 6 6.625 1560 150 168.3 150 168.3 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6500 1800 165.1 mm 6500 1560 165.1 165.1 8 8.625 8 8.625 2940 200 219.1 3400 200 219.1 10 10.750 5800 10 10.750 5020 250 273.0 250 273.0 12 12.750 9000 12 12.750 7790 300 323.9 300 323.9 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ictaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: UL LGTED ` ,DNCTON BO% CONDUIT '40/ 1. The supervisory switch contains two single pole, =����._ double throw, pre-wired switches. hr,6,• 14.NRT/' 2. Switches are rated: 1 DTEDNN�°� �� AIRE NUTS 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC FIRE ALARM TO ENPOF-LINE RESISTOR 0.25 amps c) 250 VDC °"n°LRANEL ORNEX INDICAT°R SUPERVI50RV CIRCUIT 3. Switches supervise the valve in the "OPEN" position. SWITCH CONTACT250VAC,NG: 5. One switch has two#18 insulated wiresper terminal, 50 AT 125 AND _ _ _ EM 25 WAC, 055 AT 125 VDC 025 AT 250000 ' which permit complete supervision of leads(refer � BELL to diagrams and notes below). The second switch VOLTAGE SOURCE HORN has one#18 insulated wire per terminal. This double Switch 1:2Ieada per**mina! Switch 2:1 lead per WOW circuit provides flexibility to operate two electrical devices at separate locations,such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow—51 and yellow-with- orange stripe—S2)and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue—S1 and blue-with-orange stripe—S2). In this Switch#1 =S1 example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires(e.g. brown with orange stripe). Switch#2=S2 Only S1 (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per Normally Closed: (2) Blue si NFPA 70(NEC). Common: (2)Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 jctaulic J FireLock Nxrm Dry Valve %tauIicr Series 768 30.80 A tIA, I..e— I Patent Pending Certifications/Listings: r 1 c us FM pm] (VdS) �E 104001 0832 MEA:248-98-E See Victaulic Publication 10.01 for more details. Product Description: The patent-pending Victaulic Series 768 FireLock NXT Dry Valve is a low differential, latched clapper valve that uses a unique direct acting diaphragm to separate system water supplies from dry-pipe sprinkler systems. 1 see page 12 for European trim Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 30.80 4219 Rev G Updated 01/2015 C.2015 Victaulic Company.All rights reserved. 1 jctaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Features: The low differential, unique latch and actuator design of the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns. The valve allows the water to operate a water • motor alarm and/or electric pressure alarms,which Clapper continue until the flow of water stops. With the optional Latch accelerator,the valve can be configured to respond I ; faster for use in larger systems, or where faster response IIi111 times are required. � Diaphragm The valve is rated to 300 psi/2065 kPa water working �•����A`I�,,,l1 it Assembly pressure and is factory tested hydrostatically to 600 psi/ i•�?� �� 4135 kPa for sizes 1 1/2—8"/40—200 mm.VdS trim 0 i Clapper Seal configurations are approved to 16 BAR (see page 12). 000 • 0 Required air pressure for all trim variations is 13 psi/ �� tea` 90 kPa. The Series 768 is available grooved x grooved. Exaggerated for clarity Standard grooved dimensions conform to ANSI/AWWA Note:Valve is shown in the"set"position C6O6. The Victaulic Series 768 FireLock NXT Dry Valve is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. All internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve.The valve is painted inside and out to increase corrosion resistance. The body is tapped for main drain and all available trim configurations. Installation Options The Victaulic Series 768 FireLock NXT Dry Valve is available bare, or in the following configurations: Pre-trimmed The pre-trimmed valve comes completely assembled with all necessary trim components. Vic-Quick Riser The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve(uses a Series 705W FireLock Butterfly valve—request publication 10.18;for 1 1/2 and 2740 and 50 mm sizes,the Vic-Quick Riser comes with a Series 728 Ball Valve—request publication 10.17)for system shut off, pre-set pressure switches, and a drain kit for ease of installation. For complete Vic-Quick Riser information request publication 30.20. Series 745 FireLock Fire-Pac(Available in North America only) The Fire-Pac is a completely pre-assembled fire protection valve that provides maximum service in a minimal enclosed space. The unit includes a water supply shutoff valve,the sprinkler system fire protection valve, alarm line pressure switches,air supervisory pressure switches,supervisory pump switches,and digital pressure gauges that are easily viewed through a window in the cabinet door. For complete Fire-Pac information request publication 30.23. Optional accessories ship separately. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulie victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Dimensions: The 4 Inch/114.3 Mm UI Listed,FM Approved Configuration Is Shown Below 11/2-2/48.3-60.3 mm Configurations Contain 3W/19 mm Drain Valves. 2'/2-3"/73.0-88.9 mm Configurations Contain 1 3/731 mm Drain Valves. 4-87114.3-219.1 mm Configurations Contain 2750 mm Drain Valves. Fri v/ � ns9� 4O „ `mor it--4 A 1-L4 G ' i 1 to =I j:•lUlll.i rr-TI . Ikti [ E Ilk �Inl_ji ir�i ._ ���1. �i-y ri��ir �IC:i�� I 4 D *D1 11 Ili MI I•01. .B, :tira''' ,.- mr• 1._ _.I I1��I[".� I. r � I I I .'�.i"SJin RS ija i A B I1 ■• •I r _ill , � IV* *1-1. "A, >rO I�.JI II[ *f* _ �� 1,„,,,11-11 tillII -.11 I ry J !� ��%l,)' 1.,_.i, I. i 1 II iII-,-3f MIMI 4 =l$11 oil/ K C *E1 -> Full Open Approx. Weight Dimensions Each Actual Nominal Outside Without With Size Diameter A Al B Bl C D Dl E El F G H J K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches lbs. lbs. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg kg 1'h 1.900 9.00 16.35 27.25 39.50 13.75 16.00 5.25 8.50 9.50 21.25 3.04 9.17 6.98 16.7 43.0 40 483 228.60 415.29 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.6 19.5 2 2.375 9.00 13.37 27.25 39.50 13.75 16.00 _ 5.25 8.50 9.50 21.25 3.04 9.17 6.98 17.0 43.0 50 60.3 228.60 339.60 692 1003 349 406 133 215 241 539 7721 232.91 177.29 7.7 19.5 21/2 2.875 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 65 73.0 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 76.1 mm 3.000 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 76.1 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 3 3500 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 80 88.9 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 ..... 1 4 4.500 15.03 19.83 33.50 45.50 15.00 15.75 20.50 525 9.00 10.75 21.00 6.25 9.62 8.46 59.0 95.0 100 114.3 381.76 503.68 850 1155 381 400 520 133 228 273 533 158.75 244.34 214.88 26.7 43.0 165.1 mm 6.500 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 165.1 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 22453 36.2 52.6 6 6.625 16.00 22.05 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 2050 620 9.62 8.84 80.0 116.0 150 168.3 406.40 560.07 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6 8 8.625 17.50 23.00 3350 45.50 16.75 20.00 25.25 6.25 8.75 12.75 18.50 6.05 9.40 1021 122.0 158.0 200 219.1 444.50 58420 850 1155 425 508 641 158 222 323 469 153.67 238.76 259.33 55.3 71.6 NOTES: The"A"dimension coupling is not shown in order to clarify dimensional callouts. Components shown as dotted lines denote optional equipment. *Measurements denoted with an asterisk take optional equipment into account. Optional drain connection kit is shown for reference and takeout dimensions. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 3 .ctaulid victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Performance: Hydraulic Friction Loss The chart below expresses the flow of water at 65°F/18°C through a full open valve. 4.0 1.-.®_.. lc N 2.0 i •1±F ... o t o1 o I d i h,, e #0 i .& e [ i I l E l, b A SSS;;; I � ti� � Tyyti f s G � 10 P� w0.4 ; i = 4 �,._ Y = ( j E 03 try t fi i i I 0.2 ,,,, i i 11 x i 0.1 3._ } 1..L,.4.. {, t_ 1 � -�I.� .�...4an,o-.,i I S _.,,..._._, <E 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE—GPM Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 768 FireLock NXT. Dry Valve in equivalent feet of straight pipe. Actual Equivalent Nominal Outside Length of Size Diameter Pipe inches inches feet mm mm meters a 1 Y2 1.900 3.00 40 48.3 0.914 2 2375 9.00 50 60.3 2.743 21/2 2.875 8.00 65 73.0 2.438 76.1 mm 3.000 8.00 76.1 2.439 3 3.500 17.00 80 88.9 5.182 .410. 4 4.500 21.00 100 114.3 6.401 165.1 mm 6.500 22.00 165.1 6.706 6 6.625 22.00 150 168.3 6.706 8 8.625 50.00 200 219.1 15.240 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. B jctalulic victaulic.com 4 victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Cv Values: Operation: Cv values for flow of water at+60°F/+16°C through a fully The Series 768 Dry Valve contains a clapper,which has open valve are shown in the table below. a replaceable rubber seal. The clapper makes contact with the valve's seat ring,which has access Formulas for C,values Where: holes leading into an intermediate chamber in the valve. pP=(F/Cv2 Flow Coefficient Cv The diaphragm contacts the latch,and the latch holds Q=cvxVAP Q(Flow) GPM the clapper closed. AP(Pressure Drop) psi In the closed position,the valve diaphragm is maintained in the extended position by the water supply pressure from upstream of the water supply control valve.The diaphragm latch holds the clapper in the closed position. The Series 776 Low Pressure Actuator(LPA) maintains Valve Size Full Open the water,and the system's air pressure controls the Actual LPA. Required air pressure is 13 psi/90 kPa.The design Nominal Outside of the 776 actuator does not require the traditional air Size Diameter Flow Coefficient cushion of 10—20 psi/69—138 kPa. Excess air inches inches c pressure above 13 psi/90 kPa will cause a delay in valve mm mm is, 11/2 1.900 60 operation. 40 48.3 52.0 Once the system's air pressure reduces to the trip point, 2 2375 110 the LPA opens and allows the water supply pressure in 50 60.3 95.0 21/4 2.875 180 the diaphragm to release(i.e. an open sprinkler). This 65 73.0 156.0 release allows the latch to move to its open position, 76.1 mm 3.000 180 permitting the clapper to pivot freely,thus allowing water 76.1 156.0 into the system. 3 80 889 17500 3 0 Water enters the intermediate chamber of the valve 4 4.500 350 through the holes in the seat ring. The water flows from 100 1143 302.8 the intermediate chamber to the alarm line,which 165.1 mm 6.500 6 0 1000. activates the system's alarms. The alarms continue to 6 6.625 1000 sound until the flow of water stops. 150 168.3 865.0 When the flow of water stops,the spring-assisted valve 8 8.625 1500 clapper returns to the closed position.The valve acts as 200 219.1 1499.1 an alarm check valve until the system is back in service as a dry system,according to the proper procedure. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 5 ictaulic. victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Material Specifications: Body: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Clapper:Aluminum bronze UNS-C95500 Latch:Aluminum bronze UNS-C95500 Shaft: Stainless 17-4 Clapper Seal: Peroxide cured EPDM,ASTM D2000 Bushings/Seat 0-rings: Nitrile Springs:Stainless Steel (300 Series) Diaphragm: Peroxide cured EPDM with fabric reinforcement Bill of Materials 1 Valve Body 12 Cover Plate 2 Clapper 13 Cover Plate Gasket 3 Clapper Seal 14 Cover Plate Bolts* 4 Seal Ring 15 Latch 5 Seal Washer 16 Latch Spring 6 Seal Retaining Ring 17 Latch Spring Bushing and 0-ring(Qty.2) 7 Seal Assembly Bolt 18 Diaphragm 8 Bolt Seal 19 Diaphragm Cover 9 Clapper Spring 20 Diaphragm Cover Cap Screws(Qty.8) 10 Clapper Shaft 21 Latch Shaft 11 Clapper Shaft Bushing and 0-ring(Qty.2) - \-1 m . U N o. wto 11 • ?toy/ 1. Ai;S O 0 Vii' Y v'e o - o *NOTE:The 11-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 6iotaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Trim Package Details: • Air Compressor(See page 8 for more on the Trim Packages: Victaulic Series 7C7 Compressor Package) • NOTE: See page 11 for details of trim and page 12 for Air Maintenance Trim Assembly details of European trim. • Alarm Panels 1 Galvanized components. • Drain Connection Kit 2 Series 776 Low-Pressure Actuator—The Series 776 Low-Pressure Actuator is pneumatically actuated and requires only 13 psi/90 kPa minimum air Air Supply Requirements: pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low The required air pressure for Series 768 FireLock NXT air or gas pressure of 7 psi/48 kPa. Dry Valves is 13 psi/90 kPa minimum, regardless of the system supply water pressure. Air pressures should be 3 All Required Pipe and Fittings. kept below 18 psi/124 kPa, unless a Series 746-LPA 4 All Standard Trim Accessories. Dry Accelerator is installed. Systems with air pressures higher than 18 psi/124 kPa may require the addition of a 5 All Required Gauges Series 746-LPA Dry Accelerator. Optional Trim Package: If multiple Series 768 FireLock NXT Dry Valves are 1 Black Trim for Foam Systems—If the valve is installed with a common air supply, isolate the systems intended for use in a foam system, black trim must with a spring-loaded, soft seated ball check valve to be ordered, per NFPA requirements.Specify this ensure air integrity for each system. Good practice is requirement on the order. to include a ball valve for isolation and service of each individual system. The engineer/system designer is responsible for sizing Optional Accessories: the compressor so that the entire system is charged to • Series 746-LPA Dry Accelerator—The Series the required air pressure within 30 minutes. DO NOT 746-LPA Dry Accelerator is required when the oversize the compressor to provide more airflow.An Series 768 Dry Valve is installed in large systems to oversized compressor will slow down or possibly prevent improve response time. Request submittal 30.64. valve operation. • Series 760 Water Motor Alarm—The Series 760 If the compressor fills the system too fast, it may be Water Motor Alarm is a mechanical device that necessary to restrict the air supply. Restricting the air sounds when a sustained flow of water occurs(such supply will ensure that air being exhausted from an open as with an open sprinkler). Request submittal 30.32. sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted. • Series 75B Supplemental Alarm Device—The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Request submittal 30.33. • Series 75D Water Column Kit—The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30.34. • Alarm Pressure Switch—Alarm Pressure Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs(such as with an open sprinkler). • Air Supervisory Pressure Switch—Air Pressure Supervisory Switches are used to monitor low system air pressure and are factory pre-set. • Air Supply System—The air supply system contains all components for establishing and maintaining air in the system.The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 7 ictaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Compressor Sizing: COMPRESSOR REQUIREMENTS iz 20 psi/138 kPa l 13 psi/90 kPa is f a F. • 1 g • i° • I •• CC I ce i G '' • • ro 8O o O O O O O O SYSTEM CAPACITY(in gallons) Base or Riser-Mounted Compressors: Shop Air or Tank-Mounted Air Compressors: For base or riser-mounted compressors,the recom- In the event a compressor becomes inoperative, a mended air pressure of 13 psi/90 kPa is the"on" or properly sized tank-mounted air compressor provides "low" pressure setting for the compressor. The "off" the greatest protection for systems. or"high" pressure setting should be 18 psi/124 kPa. When shop air or a tank-mounted air compressor is Victaulic offers the Series 7C7 Compressor package used, the Series 757 Regulated AMTA must be installed. for FireLock NXT devices which is riser-mounted and The Series 757 Regulated AMTA provides proper air pre-set for the FireLock NXT pressure requirements as regulation from the air reservoir to the sprinkler system. stated above. For information on the Series 7C7 package,consult publication 30.22. The Series 7C7 For tank-mounted air compressors,the recommended Compressor package is only available in North America. air pressure of 13 psi/90 kPa should be used as the set point for the air regulator.The "on" pressure of the When a base or riser-mounted air compressor supplies compressor should be at least 5 psi/34 kPa above the air to a Series 768 FireLock NXT Dry Valve, it is not set point of the air regulator. necessary to install the Victaulic Series 757 Regulated Air Maintenance Trim Assembly(AMTA). In this case, the airline of the compressor connects to the trim at the fitting where the Series 757 Regulated AMTA is normally installed (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch,the Series 757P Air Maintenance Trim Assembly with Pressure Switch should be installed. For information on the Series 757 Regulated Air Maintenance Trim Assembly,see publication 30.35. For information on the Series 757P Air Maintenance Trim Assembly, see publication 30.36. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 8 ✓ctaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Series 757 Regulated Air ,: Maintenance Trim Assembly: • Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series 757 Regulated AMTA Bill of Materials 1 W13.2 mm Restrictor 2 Slow Fill Ball Valve(Normally Open) „' 3 Air Regulator '-' 4 Strainer(100 Mesh) 5 Spring-Loaded,Soft-Seated &' fl Ball Check Valve 0 0 6 Fast Fill Ball Valve(Normally Closed) a it ' mss^/ 0.it, d✓' 0 V, Exaggerated for clarity Series 757P Air Maintenance Trim Assembly With Pressure Switch: • Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series 757P AMTA with Pressure Switch r 0 Bill of Materials 0 I ; ,I 10 Item Qty. Description I \!% 1 1 Restrictor(1/2-inch NPT) 2 1 Strainer(1/2-inch NPT) 3 1 Swing Check(1/2-inch NPT) 0 _ 4 1 Slow-Fill Ball Valve — • m (Normally Open) „N 5 1 Spring-Loaded,Soft-Seated i 0 Check Valve 6 1 Pressure Switch 7 2 Compression Fitting,Straight ' (1/4-inchNPT x1/4-inch Tube) S• � 'v- •® 0 8 1 Copper Tubing(1/4-inch OD) ® �� cr.., 9 11 Close Nipple ! victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Compressor Requirements: Remote System Test Valve Requirements Compressor Requirements and Settings for Series 768 The remote system test valve(inspector's test connection) FireLock NXT Dry Valves Installed with Series 746-LPA should contain a UL Listed and/or FM Approved valve Dry Accelerators (normally closed),which can be opened to simulate the Set the air regulator of the Series 757 Regulated AMTA operation of a sprinkler. to 13 psi/90 kPa. The remote system test valve(inspector's test connection) THE SERIES 757P AIR MAINTENANCE TRIM should be located at the most hydraulically ASSEMBLY WITH PRESSURE SWITCH MUST NOT BE demanding location in the release system. USED ON A SERIES 768 FIRELOCK NXT DRY VALVE NOTE: Multiple restrictions on the remote system test INSTALLED WITH A SERIES 746-LPA DRY valve(inspector's test connection) may slow the air ACCELERATOR. decay rate and cause the system to respond slower than required. When a Series 768 FireLock NXT Dry Valve is installed with a Series 746-LPA Dry Accelerator, the Series 757 The remote system test valve(inspector's test connection) Regulated AMTA must be used. NOTE:The use of an air should terminate with an orifice equal to the regulator with a base or risermounted compressor could smallest orifice in the releasing system. cause short cycling, resulting in premature wear of the The remote system test valve(inspector's test connection) compressor. is used to ensure that water reaches the most remote In the event a compressor becomes inoperative,a part of the system within 60 seconds. properly sized tank-mounted air compressor provides the greatest protection for systems installed with a Series 746-LPA Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. NOTE:The Series 757 Regulated AMTA must be used with a tank-mounted air compressor or shop air system that continually supplies air to a Series 768 FireLock NXT Dry Valve installed with a Series 746-LPA Dry Accelerator. The air regulator of the Series 757 Regulated AMTA is a relief-type design. Any pressure in the system that is above the set point of the air regulator will be released. Therefore, charging the air regulator above the set point could cause premature operation of a valve installed with a Series 746-LPA Dry Accelerator. NOTE:The series 746-LPA should not be used above 30 psi. If higher pressures are required,the series 746 should be used. Settings for Air Supervisory Pressure Switches and Alarm Pressure Switches Air supervisory pressure switches are required for dry systems and must be set according to the following instructions. NOTE:Switches for Vic-Quick Risers are pre-set at the factory. Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition,the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement. Set the air supervisory pressure switches to activate at 2—4 psi/14—28 kPa below the minimum air pressure required, but not lower than 10 psi/69 kPa. Wire the alarm pressure switch to activate a water flow alarm. Set the alarm pressure switch to activate on a pressure rise of 4—8 psi/28—55 kPa. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 10 ✓ctaulic' victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— Trim Components (c us <> Trim) LISTED Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Ser01 1 Seriesies 7 768 FireLock NXT Dry Valve 10 2 FireLock Rigid Coupling(OptionaV Sold Separately—Comes Standard I when VQR Assembly is Ordered) 4.4 i m ..------- 3 3 Water Supply Main Control Valve From System (OptionaVSoldSeparately—Comes Air Feed y l i 0 Standard when VQR Assembly is Ordered) *lid� ; I j 4 Drain Swing Check Valve T — 5 Drip Cup with Cap �/.� -J 6 Alarm Pressure Switch(Optional/Sold .� Separately—Comes Standard when VQR - Assembly is Ordered) re ® •V- London 7 Series 729 Drip Check Valve m O 8 Diaphragm-Charge-Line Ball Valve (Normally Open) j =i L�11�. 9 3-in-1 Strainer/Check/Restrictor I %" I Assembly Ali i t V o '.y' !.y 10 Series 760 Water Motor Alarm Za �l ® (Optional/Sold Separately) ® �t i , /\) �\ 11 Alarm Test Ball Valve 0 `,� I 13 '.' "' 12 Diaphragm-Charge-Line Pressure s �� a 71 `/� TODripooat Cup Gauge(0-300 psi/0-2068 kPa/0-20.7 Bar) /ii 1<< To Dtlp Cup Loa Non ,�Il �i`) �.a 1� Location A lo.. 13 Series 749 Auto Drain ®0 v �- •� O �O 14 Series 746-LPA Dry Accelerator b �,L O� Assembly(OptionaVSold Separately) ` 15 Series 776 Low-Pressure Actuator �� f 16 Air Manifold Notes \, v sy sem I rst:� 17 Air Supervisory Pressure Switch \, (Optional/Sold Separately—Comes �.,\ \-,\ 1 ® *Jr Standard when VQR Assembly is Ordered) m / 18 System Pressure Gauge 1` I 1 I \s\ \ u' t 4, (0-80psVO-552kPa/0-5.5 Bar with Retard) O� �({t \, �� .,, � , 19 Water Supply Main Drain Valve- ® �fi. I \ ��` 44°17:60.,20 } Flow Test J� t,�� 11104 11 ��`� �� ! fo C'• \. 46 t,20 Water Supply Pressure Gauge J � `'�`'t/ �- I ,, (0-300 psi/0-2068 kPa/0-20.7 Bar) •� ;:.0'^\,\ O ej*\r =� 21 Drain Connection Kit(Optional/Sold ; `\ \ 'r '----m,.„ ----m—J Separately—Comes Standard when VQR Assembly is Ordered) L 22 Gauge Valve �� I�. 23 System Main Drain Valve o i it 24 Series 748 Ball Check Valve i IP © R1. 1...._ To TLo�aOnP0 ^ -- -- • iitl 0 41.9V p" From Water Supply Exaggerated for clarity Optional devices include the Series 75D Water Column Device Kit and the Series 75B Supplemental Alarm Kit. NOTE 1:Connection point for the Series 75D Water Column Device Kit. For installation of the Series 75B Supplemental Alarm Device,refer to the instructions supplied with the product. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 11 ictaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— Trim Components: C((European Trim: C 0 us FM [PCB]BI /pP) 104f/01 �32 •ids ► tT MEA:248-98-E �J Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Materials i) I 1 Series 768 FireLock NXT Dry Valve 2 FireLock Rigid Coupling(Optional/Sold 1 Separately-Comes Standard when VQR V I Assembly is Ordered) FromSyrtem �� 1 m Air Feed / 3 Water Supply Main Control Valve(Optional/ �� r'� y 1 1 0 / Sold Separately-Comes Standard when VQR Yj i `= Assembly is Ordered) 0 --I / 4 Drain Swing Check Valve ►'' li J / 5 Drip Cup with Cap �� / 6 Alarm Pressure Switch(OptionaVSold / Location v li' Separately-Comes Standard when VQR 0 Assembly is Ordered) 7 Series 729 Drip Check Valve i 204r: .111 8 Diaphragm-Charge-Line Ball Valve 1 i�il (Normally Open) i*I. I z4 I�1 / �!e 9 3-in-1 Strainer/Check/Restrictor / #A Assembly ® I I �� I ®To Drip Cup 10 Series 760 Water Motor Alarm �?i J �- �.e# To Drip °On �, (Optional/Sold Separately) I p 11 Alarm Test Ball Valve ® a '� j C` �y�/ cORe 12 Diaphragm-Charge-Line Pressure --s' b1 ` O Gauge(0-300 psi/0-2068 kPa/0-20.7 Bar) . 2, T 1 %' T 'I �j 13 Series 749 Auto Drain sytem �J 14 Series 746-LPA Dry Accelerator Note t f ® / Assembly(Optional/Sold Separately) N. T ® -� t...-— 15 Series 776 Low-Pressure Actuator m / I \- �'-\ �� / 16 Air Manifold f.� .` I "-- - 17 Air Supervisory Pressure Switch(OptionaVSold �{" i ��� 41 Separately-Comes Standard when VQR ® O� �- fail? n ,�f� ���I, j .>,► Assembly is Ordered) - J I l o L 18 System Pressure Gauge <f-• ✓,'. (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) ® ° i 19 Water Supply Main Drain Valve- o z5 Flow Test I . x--49# 20 Water Supply Pressure Gauge S'_'* (0-300 psi/0-2068 kPa/0-20.7 Bar) • 0 21 Drain Connection Kit(Optional/Sold © cc...;,..---,1 To Drip 1 li[ Separately-Comes Standard when VQR "�' Cup 6 `- Assembly is Ordered) = ,� `anon 22 Gauge Valve i► v*,... - A 6 23 System Main Drain Valve Qi ' 24 Series 748 Ball Check Valve © , / 'J 25 Water Motor Alarm Shutoff Valve I j /` (Normally Open)° 'Item 25,water motor alarm shutoff valve,can be closed to prevent water from flowing rr into the Series 760 Water Motor alarm during conditions that are not favorable for the alarm to sound lie during a trip test). From Water SupplY 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 12 ictaul.c victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage,or valve leakage. If you need additional copies of this product literature or the valve installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone:001-610-559-3300. Installation Note Reference should always be made to the appropriate Installation,Maintenance,and This product shall be manufactured by Victaulic or to Victaulic specifications.All products Testing Manual included with each shipment of Victaulic products.These manuals are also to be installed in accordance with current Victaulic installation/assembly instructions. available in PDF format on our website at victaulic.com Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic®and FireLockn are registered trademarks of Victaulic Company. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 13 ✓ctauliC IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 30.35 FireLock° Devices Air Maintenance Trim Assembly SERIES 757 PROPER AIR SUPPLIES FOR SERIES 1.When a riser or base mounted air compressor is being used to supply air to a dry valve or preac- 756/SERIES 758/SERIES 768/SERIES769 tion system it is not necessary to use the air maintenance trim assembly with the air regulator. In this ACTUATED VALVES: circumstance the air line of the compressor is connected to the valve trim at the fitting into which the Air Maintenance Trim is normally installed. When the valve is used with this setup it is the engineer/system designer's responsibility to size the compressor so that the compressor brings the entire system to the required pressure in 30 minutes. The compressor must not be oversized to provide more air flow as this will slow down or possibly prevent the operation of the valve.It must further be emphasized that the base mounted compressor does not provide any backup air to the system and that continuous service(24 hours per day,7 days per week)must be maintained in order to prevent the potential of false tripping of the valve due to loss of air pressure. Additionally,due to the large on/off differential available on pressure switches that control base mounted compressors,the compressor pressure switch must be adjusted so that the"ON"contact of the pressure switch is set a minimum of 5psi higher than the set point of the regulator. 2.When shop air or a tank mounted air compressor is being used,the Air Maintenance Trim Assembly(AMTA)must be used.The AMTA is designed to provide the proper air regulation to the sprinkler system which will assure the proper operation of the Fire Safety Valve. In the event of a compressor becoming inoperative the tank mounted air compressor provides the greatest protection.With a properly sized tank,air can be continuously supplied to the sprinkler sys- tem for an extended period of time even with a loss of compressor. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 11111111111111 111111111 11 WCAS-7MYM68 For complete contact information,visit www.victaulic.com 30.35 2515 REV D UPDATED 1/2009 iCtaUljc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 30.35 • I'm also available In a BASEPLATE UNIT Pc_Aoll I RE Joh hit f1_,.....,10,fr. , 1 . imp. f� ii ill,!....,..r_11 me _ . ... .,..., ipir . gi ,” .,....., 11, iir.,,,, . .,% '',r tIllit tr„„, M , 4„ c, COMPRESSORS � �� ~' Y4 .. ..... .. S300 .. . ....,., . , .. . .............. . .......,. . . , . ... . . PRODUCT NUMBERING SYSTEM S300H - SD11 II ,-,1 1 5 ,, ' 1.5 HP I 1 11 1 1 1 Ll ////►►f►► SYSTEM CAPACITY< MOUNTING OPTIONS` SERIES PHASE VOLTAGE ADDITIONAL OPTION 3.8 CFM M HD SD B:Baseplate HD:Heavy Duty t Single Phase 11 It,;:::”swd P:Prewired Power Cord • 175 300 H:Horizontal Tank SD:Standard Duty 3:Three Phase 230 2000000 $:Prewired Magnetic Starter 265 2000 V:Vertical Tank as0 U:30-00psi Pressure Switch 325 toaVo�ssrb and m�e�o 500 lIdn avadame m ru aid sal >0 300 GAL. MAX CAP. 1700 `Greyed out options do not apply to this unit «S31)OH-ODD-115 is a stocked hero 27" x 12" x 22" ■ SPECIAL ORDER OPTIONS: SINGLE PHASE 1Phase:il5v/200v/230v VOLTS . S.F. 70-100 PSI -3 Phase:200v/230v/460v 10 los � .o -Power Cord 230 EICI 1.0 -3 Phase Starter THREE PHASE 85 LBS• -30-40 PSI Pressure Switch VOLTS AMPS S.F. -Horizontal or Baseplate Mount 208Emir]230 En® 1/2" MPT ■ DON'T FORGET YOUR INSTALLATION KIT! aeo ®® 'C' The Advantage 26549 FallbrookAvenue,Wyoming,MN 55092//800.762.2247//651.462.3440//www.c-aireinc.com