Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
r v j c s'- I'i'i k'5 �� �(4'--7� ' it E.4',,..,r,,,. . .-„3„ tqcot" Worldwide Fire Protection �� Contacts www.tyco-fire.com Products i-,,,, s P„” dam\(4 3 T F p t,',"" 1)(-71,71041'V Series TY-FRB — 2.8, 44 2. 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General when exposed to corrosive atmo- spheres. Although corrosion-resistant Description coated sprinklers have passed the standard corrosion tests of the appli- . - The TYCO Series TY-FRB, 2.8, 4.2, cable approval agencies,the testing is 4* 1 , _ 5.6,and 8.0 K-factor,Upright,Pendent, not representative of all possible cor- rosive atmospheres. Consequently, and Recessed Pendent Sprinklers it is recommended that the end user described in this data sheet are quick be consulted with res ect to the suit- , response, standard coverage, deco- p rative 3 mm glass bulb-type spray ability of these coatings for any given sprinklers designed for use in light or corrosive environment. The effects of ordinary hazard,commercial occupan- ambient temperature,concentration of `. chemicals, andgas/chemical velocity, cies such as banks, hotels, and shop- Y • a, ping malls. should be considered, as a minimum, "" -- along with the corrosive nature of the The recessed version of the Series chemical to which the sprinklers will be TY-FRB Pendent Sprinkler, where exposed. applicable, is intended for use in areas An intermediate level of the Series with a finished ceiling. This recessed TY-FRB Pendent Sprinklers is detailed pendent sprinkler uses one of the in Technical Data Sheet TFP356, and following: Sprinkler Guards are detailed in Tech- r-1.,,• A two-piece Style 10(1/2 inch NPT) nical Data Sheet TFP780. " or Style 40(3/4 inch NPT)Recessed Escutcheon with 1/2 inch (12,7 mm) NOTICE - of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment The Series TY-FRB, 2.8, 4.2, 5.6, from the flush pendent position,or a and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers • A two-piece Style 20(1/2 inch NPT) described herein must be installed or Style 30(3/4 inch NPT)Recessed and maintained in compliance with a Escutcheon with 1/4 inch (6,4 mm) this document and with the applica- bs of recessed adjustment or upto 1/2 " ble standards of the National Fire Pro- inch (12,7 mm) of total adjustment tection Association, in addition to the from the flush pendent position. standards of any authorities having The adjustment provided by the jurisdiction.Failure to do so may impair Recessed Escutcheon reduces the the performance of these devices. Sprinkler accuracy to which the fixed pipe drops The owner is responsible for maintain- Identification to the sprinklers must be cut. ing their fire protection system and Corrosion-resistant coatings, where devices in proper operating condition. Number (SIN) applicable,are utilized to extend the life The installing contractor or sprinkler of copper alloy sprinklers beyond that manufacturer should be contacted with which would otherwise be obtained any questions. TY1131 - Upright 2.8K, 1NPT TY1231 -Pendent 2.8K, 1/2"NPT (� l � TY2131 -Upright 4.2K, 1/2"1/2NNPT r..2_ —, TY2231 -Pendent 4.2K,1/2'"NPT IMPORTANT � � �� ®p� TY3131 -Upright 5.6K, 1/2"NPT Always refer to Technical Data TY3231 -Pendent 5.6K, 1/2"NPT Sheet TFP700 for the "INSTALLER TY4131 - Upright 8.0K,3/4"NPT WARNING" that provides cautions TY4231 - Pendent 8.0K,3/4"NPT with respect to handling and instal- TY4831 -Upright 8.0K, 1/2"NPT lation of sprinkler systems and corn- TY4931 - Pendent 8.0K, 1/2"NPT ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 10 NOVEMBER 2015 TFP171 TFP171 4 Page 2 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 7 - Bushing 7 7/16" � r (11,1 mm) POs 3 NOMINAL I � `i i f 2 1/4" -Z� 2 4 $ i ________ MAKE-INl 1 (57,2 mm) Irkiii �� 2-3/16" 4 (55,6 mm) ii 1 9/16" (39,7 mm) 4. %R 5 / /l-iti ...w '' 6* 1/2"NPT** f WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY//3/)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE f110,4 ii, �i3 7/16" 71=---=-----__=-=� � (11,1 mm) II � I� Y/ �i 2 i NOMINAL 2-3/16" 0 — MAKE-IN i (55,6 mm) 4 0 `�s- 2-3/16" ii1-1/2" II,, (55,6 mm) I(38,1 mm) ik—5 • ■ Air 6* 1/2" NPT** f WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. . - FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on 2 - Button Assembly Screw Deflector. special request. ESCUTCHEON 4 - Bulb 6 - Deflector* PLATE SEATING SURFACE O/<_r/_i_,1.1\�� _______ / ��— 1 ____ 7/16" ____ `��1:____ 3 014 (NOMINAL ___ ,..,._ 2 3/16" ��� �li r A / 2 MAKE-IN - (55,6 mm) 4 `-1 2-3/16" 1-1/2" I (55,6mm) (38,1 mm) P--------5 •--A - 0 ,_mac_-41. ... 6* 1/2" NPT** WRENCH STYLE 10 or 20 2-7/8"(73,0 mm)DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT l- TFP171 Page 3 of 10 *Temperature rating ** Pipe thread connections per 1 - Frame 3 - Sealing 5 - Compression is indicated on ISO 7-1 can be provided on ESCUTCHEON 2 - Button Assembly Screw Deflector. special request. PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE Y- , / ----=-----x 1/2" p off I' 3 4 (121,7/2m" 12 7/m"m) ' � t NOMINAL 2-5/16" ���r MAKE-IN (58,7 mm) ` A, 2 f_. i = 2 1/4" 1-9/16" I 4 (57,2 mm) 0 (39,7 mm) 410 3/4"NPT** t WRENCH STYLE 30 or 40 + � 6 FLATS RECESSED 2-7/8'(73,0 mm)DIA. - UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,3/4 INCH NPT CEILING PLATE 1 - Frame 5 - Compression SEATING SURFACE 2 - Button Screw �,�-r__ __%-`,, 1 3 Sealing 6 Deflector It t Assembly 7/16" IA 3 4 - Bulb (11, mm2-1/4"pi MINA1L) (57,2 mm) c4 2 `=,rAKE-IN i * Temperature rating is 2-3/16" 1-9/16" I 4 indicated on Deflector. (55,6 mm) I I (39,7 mm) \ f��5 ** Pipe thread connections i 114� \- * per ISO 7-1 can be 6 provided on special 1/2" NPT** t WRENCH request. UPRIGHT FLATS PENDENT CROSS SECTION FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT G- WRENCH RECESS WRENCH RECESS (END"A" USED FOR ��!f ^ 1/2"NPT MODELS) WRENCH RECESS (END"B"USED FOR ��� 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 FIGURE 7 W-TYPE 6 SPRINKLER W-TYPE 7 RECESSED WRENCH SPRINKLER WRENCH TFP171 Page 4 of 10 Do not attempt to compensate for Technical Design insufficient adjustment in the Escutch- eon Plate by under- or over-tightening Data Criteria the sprinkler. Re-adjust the position of Approvals The TYCO Series TY-FRB, 2.8, 4.2, the sprinkler fitting to suit. UL and C-UL Listed 5.6,and 8.0 K-factor,Upright,Pendent, Series TY-FRB Upright and Pendent FM,LPCB,and NYC Approved and Recessed Pendent Sprinklers are Sprinklers Refer to Table A and B for complete intended for fire protection systems The Series TY-FRB Pendent and approval information including corrosion- designed in accordance with the stan- Upright Sprinklers must be installed resistant status. dard installation rules recognized by in accordance with the following Maximum Working Pressure the applicable Listing or Approval instructions. agency (such as, UL Listing is based Refer to Table C. Step 1.Install Pendent sprinklers in the on the requirements of NFPA 13, and Install position. upright Discharge Coefficient FM Approval is based on the require- ppendentlers in the upright position. sprin- K=2.8 gpm/psi' (40,3 Ipm/bard) ments of FM's Loss Prevention Data K=4.2 gom/osi1/2(60.5 lom/bar''l Sheets). Only the Style 10, 20, 30, or Step 2. With pipe-thread sealant K=5.6 gpm/psiy2(80,6 Ipm/barye) 40 Recessed Escutcheon, as applica- applied to the pipe threads, hand- K=8.0 gpm/psi°(115,2 Ipm/barye) ble,is to be used for recessed pendent tighten the sprinkler into the sprinkler installations. fitting. Temperature Rating Refer to Table A and B. Step 3. Tighten the sprinkler into the Installation sprinkler fitting using only the W-Type Finishes 6 Sprinkler Wrench(Figure 6).With ref- Sprinkler:Refer to Table D. The TYCO Series TY-FRB,2.8,4.2,5.6, erence to Figures 1 through 5, apply and 8.0 K-factor,Upright,Pendent,and the W-T e 6 Sprinkler Wrench to the Recessed Escutcheon:Signal or Pure YP p White,Jet Black,Chrome Plated,or Recessed Pendent Sprinklers must sprinkler wrench flats. Natural Brass be installed in accordance with this section. Series TY-FRB Recessed Pendent Physical Characteristics Sprinklers Frame Bronze General Instructions The Series TY-FRB Recessed Pendent Button Brass/Copper Do not install any bulb-type sprinkler Sprinklers s must be in Sealing Assembly..Beryllium Nickel w/TEFLON if the bulb is cracked or there is a loss Sprin with the t be installedslin accor- Bulb Glass of liquid from the bulb.With the sprin- tions. Compression Screw Bronze kler held horizontally,a small air bubble Step A.After installing the Style 10,20, Deflector Copper/Bonze should be present.The diameter of the 30, or 40 Mounting Plate, as applica- Bushing(K=2.8) air bubble is approximately 1/16 inch ble,over the sprinkler threads and with Operation (1,6 mm)for the 135°F(57°C)and 3/32pipe-thread sealant applied to the pipe inch(2,4 mm)for the 286°F(141°C)tern- threads,hand-tighten the sprinkler into The glass bulb contains a fluid that perature ratings. the sprinkler fitting. expands when exposed to heat.When A leak-tight 1/2 inch NPT sprinkler Step B. Tighten the sprinkler into the the rated temperature is reached, the joint should be obtained byapplying a s sprinkler fittingusingonlythe W T e fluid expands sufficiently to shatter the p yp glass bulb, allowing the sprinkler to minimum to maximum torque of 7to 7 Recessed Sprinkler Wrench (Figure activate and water to flow. 14 ft.-lbs. (9,5 to 19,0 Nm).A leak tight 7). With reference to Figures 1 to 4, 3/4 inch NPT sprinkler joint should be apply the W-Type 7 Recessed Sprinkler obtained with a torque of 10 to 20 ft.- Wrench to the sprinkler wrench flats. lbs. (13,4 to 26,8 Nm). Higher levels of Step C. After ceiling installation and torque can distort the sprinkler Inlet finishing, slide on the Style 10, 20, 30, with consequent leakage or impairment or 40 Closure over the Series TY-FRB of the sprinkler. Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. f TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** FACTOR COLOR BRASS PLATED 135°F(57°C) Orange PENDENT 155°F(68°C) Red (TY1231) and 175°F(79°C) Yellow 1,2,3,4 UPRIGHT (TY1131) 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange 2.8 RECESSED 1/2"NPT PENDENT 155°F(68°C) Red (TY1231)* 175°F(79°C) Yellow Figure 8 200°F(93°C) Green 135°F(57°C) Orange 1,2,4 RECESSED PENDENT 155°F(68°C) Red (TY1231)** 175°F(79°C) Yellow Figure 9 200°F(93°C) Green 135°F(57°C) Orange (ENDEN)T 155°F(68°C) Red and 175°F(79°C) Yellow UPRIGHT (TY2131) L 200°F(93°C) Green J 286°F(141°C) Blue 135°F(57°C) Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F(68°C) Red 1,2 F ginee 1)* 175°F(79°C) Yellow 200°F(93°C) Green 135°F(57°C) Orange RECESSED PENDENT 155°F(68°C) Red (TY2231)** 175°F(79°C) Yellow Figure 11 200°F(93°C) Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only. N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS t TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME POLYESTER*** LEAD FACTOR COLOR BRASS PLATED COATED 135°F(57°C) Orange PENDENT (TY3231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F(93°C) Green (TY3131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 5.6 PENDENT 175°F(79°C) Yellow 1,2,4,5 N/A 1/2"NPT (TY3231)* Figure 12 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,4,5 N/A (TY3231)** Figure 13 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT (TY4231) 155°F(68°C) Red and 175°F(79°C) Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F(93°C) Green (TY4131) 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red 8.0 PENDENT 175°F(79°C) Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 14 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange RECESSED 155°F(68°C) Red PENDENT 175°F(79°C) Yellow 1,2,3,5 N/A (TY4231)** Figure 15 200°F(93°C) Green 286°F(141°C) Blue 135°F(57°C) Orange PENDENT 155°F(68°C) Red 8.0 (TY4931) and 175°F(79°C) Yellow 1,2,4,5,6 1,2,5 1/2"NPT UPRIGHT (TY4831) 200°F(93°C) Green 286°F(141°C) Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. 'Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. **'Frame and Deflector only. N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS t TFP171 Page 7 of 10 SPRINKLER FINISH KTYPE NATURAL OLEAD FACTOR NABRASS I CHRPLATEDME POLYESTER COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) ______>.1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY2231) PENDENT(TY3231) and 5.6 UPRIGHT(TY3131) 250 PSI(17,2 BAR) 1/2"NPT OR 175 PSI(12,1 BAR) RECESSED (SEE NOTE 1) PENDENT(TY3231) PENDENT(TY4231) and 175 PSI 8.0 UPRIGHT(TY4131) (12,1 BAR) 3/4"NPT 175 PSI(12,1 BAR) RECESSED PENDENT(TY4231) N/A 8.0 PENDENT(TY4931) and1/2"NPT UPRIGHT(TY4831) 175 PSI(12,1 BAR) (121 BSI AR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Under- writers Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE Care and have not operated,should be replaced Care must be exercised to avoid if they cannot be completely cleaned damage to the sprinklers -before, Maintenance by wiping the sprinkler with a cloth or during, and after installation. Sprin- by brushing it with a soft bristle brush. klers damaged by dropping, striking, The TYCO Series TY-FRB must be Care must be exercised to avoid wrench twist/slippage,or the like,must maintained and serviced in accordance damage to the sprinklers before, be replaced. Also, replace any sprin- with this section. during, and after installation. Sprin- kler that has a cracked bulb or that has Before closing a fire protection system klers damaged by dropping, striking, lost liquid from its bulb. (Ref. Installa- main control valve for maintenance wrench twist/slippage,or the like,must tion Section). work on the fire protection system be replaced. Also, replace any sprin- Initial and frequent visual inspections of that it controls, obtain permission to kler that has a cracked bulb or that has random samples are recommended for shut down the affected fire protection lost liquid from its bulb. (Ref. Installa- corrosion-resistant sprinklers to verify systems from the proper authorities tion Section.) the integrity of the corrosion-resistant and notify all personnel who may be The owner is responsible for the material of construction. Thereafter, affected by this action. inspection,testing,and maintenance of annual inspections per NFPA 25 should their fire protection system and devices suffice. Absence of the outer piece of an escutcheon, which is used to cover in compliance with this document, as Inspections of corrosion-resistant a clearance hole, can delay sprinkler well as with the applicable standards sprinklers are recommended at close operation in a fire situation. of the National Fire Protection Asso- range, instead of from the floor level ciaSprinklers which are found to be the tstaionndards of any other authorities per NFPA. Inspection the close exact range leaking or exhibiting visible signs of having jurisdiction.Contact the install- can bettercondition determine thee in eg- corrosion must be replaced. in contractor or sprinkler manufac- rity ofhe andcorrosion-resistant smaterial,m i g p rity the turer regarding any questions. which can be affected by the corrosive Automatic sprinklers must never be painted, plated, coated, or other- Automatic sprinkler systems are rec- conditions present. wise altered after leaving the factory. ommended to be inspected, tested, Modified sprinklers must be replaced. and maintained by a qualified Inspec- Sprinklers that have been exposed to tion Service in accordance with local corrosive products of combustion, but requirements and/or national codes. , TFP171 Page 8 of 10 2-7/8" DIA. 1 2-7/8" DIA. (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2"(12,7 mm) 5/8±1/4" 1/2±1/8" (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4" DIA. 1/4"(6,4 mm) 2-1/4" DIA. 57,2 mm (57,2 mm) ( ) 1 FACE OF MOUNTING / FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" / (3,2 mm) (3,2 mm) _� �_ �1 'll T 1 ,i , 1777��20_1_ illy} SURFACEOMOUNTING MOUNTINGSURFACE , •w�� ii �� 1-5/16"(33,3 mm) SERIES 1-5/16"(33,3 mm) CLOSURE SERIES CLOSURE TY-FRB 1-1/16"(27,0 mm) TY-FRB 13/16"(20,6 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH W O-P ECE 1/2 INCH TOTAL 2RECESSED ESCUTCHEON MENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 2-7/8" DIA. 73,0 mm) f- (73,0 mm) 1/2"(12,7 mm) 5/8±1/4" ( 3/4"(19,1 mm) 1/2±1/8" (15,9±6,4 mm) 1/4"(6,4 mm) (12,7±3,2 mm) 2.1/4" DIA. 1/4"(6,4 mm) 2-1/4"DIA. (57,2 mm) / FACE OF f- (57'2 mm) MOUNTING / FACE OF MOUNTING SPRINKLER PLATE SPRINKLERr--- PLATE FITTING FITTING 1/8" / 1/8" / (3,2 mm) (3,2 mm) �� �i 7 -- ----1__t Imo'. 7JP MO IN ,IMOUNTING ■ SURFACE . SURFACE .. ' 1-1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE SERIES CLOSURE TY-FRB 1"(25,4 mm) TY-FRB 3/4"(19,1 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE O-P E2RECESSED/2 INCH TOTAL ESCUTCHEON STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT 4.2 K-FACTOR, 1/2 INCH NPT TFP171 Page 9 of 10 2-7/8"DIA. 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) (15,/8±1 mm) 1/2±1/8" 1/2"(12,7 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 1/4' 2-1/4" DIA. (6,4 mm) FACE OF (57,2 mm) 57,2 mm MOUNTING FACE OF S FRIM L R NER PLATE SPRINKLER ( ) MOUNTING PLATE / FITTING 1/8" 1/8" (3• ,2 mm) / 1101-11 l� �I O (3,2 mm) �� -- PT7�i. °1- MOUNTING SURFACE ,�' NTIts:( 17 / SURFACE -_��,_;_. PI CLOSURE SERIES 1 1/4"(31,8 mm) SERIES 1-1/4"(31,8 mm) CLOSURE TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8"DIA. 2-7/8" DIA. _ 5/8±1/4" (73,0 mm) 3/4'(19,1 mm) (73,0 " 1/2±1/8" mm) 1/2 (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4'(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) / FACE OF (57 2 mm) MOUNTING / (57,2 mm) SPRINKLER FACE OF MOUNTING PLATE SPRINKLER PLATE FITTING FITTING / 1/8" / 1/8" (3,2 mm) i (3,2 mm) A2-4 r 2 1.11nit i MOUNTING 11110MOUNTINGSURFACE SURFACE �. CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 14 FIGURE 15 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR,3/4 INCH NPT 8.0 K-FACTOR,3M INCH NPT TFP171 Page 10 of 10 P/N 57 - XXX - X - XXX I SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 3 PURE WHITE1 155 155°F(68°C) POLYESTER(RAL9010) 340 4.2K UPRIGHT(1/2"NPT) TY2131 4 SIGNAL WHITE 175 175°F(79°C) POLYESTER(RAL9003) 341 4.2K PENDENT(1/2"NPT) TY2231 5 JET BLACK2 200 200°F(93°C) POLYESTER(RAL9005)2 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141°C) 371 5.6K PENDENT(1/2"NPT) TY3231 9 CHROME PLATED 390 8.0K UPRIGHT(3/4"NPT) TY4131 NOTES: 1. Eastern Hemisphere sales only. 391 8.0K PENDENT(3/4"NPT) TY4231 2. Available in only and 200°F(93°C);2.8K, lead time to manufaand 8.0K,155°F cture. 360 8.0K UPRIGHT(1/2"NPT) TY4831" 361 8.0K PENDENT(1/2"NPT) TY4931" TABLE D SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS PART NUMBER SELECTION Limited Ordering Warranty Procedure For warranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When placing an order, indicate the full product name and Part Number(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB (Specify SIN), (specify K-factor), (specify Pendent or Upright)Sprinkler(specify)temperature rating, (specify) finish or coating, P/N (specify from Table D) Recessed Escutcheon Specify: Style (10, 20, 30, or 40) Recessed Escutcheon with (specify") finish, P/N(specify") Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 "Refer to Technical Data Sheet TFP770 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products,LP. All rights reserved. tycc TEFLON is trademark of The DuPont Corporation. Fire Protection Products I FireLock® V27, K5.6 ✓ctaulic® Models V2709,V2710 40.11 Standard Spray Technical Specifications: Horizontal and Recessed Horizontal Sidewall Standard and Quick Response Models: V2709, V2710 Style: Horizontal Sidewall or Recessed • Horizontal Sidewall .� _�� �� ? ��`�� Nominal Orifice Size: 1/z"/13 mm `a 1 K Factor: 5.6 Imp./8.1 S.I.1 Nominal Thread Size: 1/2"/15 mm V2709/V2710 V2709/V2710 Max. Working Pressure: Standard Horizontal Recessed Horizontal Sidewall Sidewall • 175 psi/1200 kPa (FM) • 250 psi/1725 kPa (UL) Approvals/Listings: Factory Hydrostatic Test: 100% © 500 psi/3450 kPa c®us ® LPCB ® Min. Operating Pressure: LISTED • 7 psi/48 kPa See Victaulic Publication 10.01 for more details. Temperature Rating: See chart on page 3 For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. Product Description: These Model V27, standard spray horizontal sidewall / sprinklers are designed for up to ordinary Hazard per NFPA 13, and can be used for standard or recessed installations. The design provides a crescent-shaped water discharge pattern for installation along a wall or under a beam or ceiling. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 At�1 recessed escutcheon which provides up to 3/4"/19 mm of �\ adjustments. Coverage 1 For coverage area and sprinkler placement, refer to , NFPA 13 or applicable standard. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock®I K5.6, V27 I Publication 40.11 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaulic® victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 . Material Specifications: Accessories Horizontal Deflector: Commercial bronze per Installation Wrench: UNS C22000 Open End: V27 Bulb: Glass with glycerin solution I Recessed: V27-2 Bulb Nominal Diameter: Standard: 5.0 mm Sprinkler Finishes: [0/ Quick Response: 3.0 mm Plain Brass Load Screw: Low Silicon bronze per UNS C65100 Chrome plated Pip Cap: Low Silicon bronze per UNS C65100 V White painted3 Spring: Beryllium nickel Flat black painted3 Seal: Teflon2 tape Custom painted3 Frame: Die cast brass 65-30 ❑ Proprietary Nickel/Teflon2 coating3 Lodgement Spring: Stainless steel per UNS S30200 VC-2504 155, 200, 286 SR Only: Wax3 For cabinets and other accessories refer to separate sheet. NOTE:Weather resistant recessed escutcheon available upon request. 2 Teflon is a registered trademark of Dupont Co. 3 UL Listed for corrosion resistance. 4 UL Listed and FM Approved for corrosion resistance. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. �CtaU�iC® victaulic.com 2 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Approvals/Listings: APPROVALS/LISTINGS Model V2709 V2709 Recessed V2710 V2710 Recessed V2710 Recessed Orifice Size(inches) '/2" 1/2" 1/2" 1/2' Orifice Size(mm) 13 " 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor S.I.6 8.1 8.1 5.6 8.1 5.6 8.1 5.61 Quick Standard Standard Quick Quick Recessed Recessed Recessed Deflector Type Horizontal Horizontal Horizontal Horizontal Horizontal Sidewall Sidewall* Sidewall Sidewall(up to Sidewall(up to 1/2"adjustment) 3/<"adjustment) Approved Temperature Ratings F°/C° 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C cULus 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C FM 6 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C None 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C NYC/MEA 6#62-99-E 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C CSFM 6#7690-0531:112 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 286°F 141°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 6104b/01 175°F/79°C 155°F/68°C None 175°F/79°C None None 6104b/02 200°F/93°C 286°F/141°C 200°F/93°C 360°F/182°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C VNIIPO 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 200°F/93°C 175°F/79°C 175°F/79°C 286°F/141°C 200°F/93°C 200°F/93°C 175°F/79°C None 360°F/182°C 286°F/141°C 200°F/93°C CCCf ZSTBS None 155°F/68°C None None None 5 For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 6 Light Hazard ONLY Note:Listings and Approvals as of printing.All are approved open. • 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ✓ctaulic* victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Dimensions: 3"/89 mm 2/4757 mm —►{ � 7/16/m 1 I 11 m � _I® ----- 32 mm I1M�I 8mm- 1 Standard HSW–V2709,V2710 11/16'% ' 23/16"/ 17mm 11/16" 11/16"/ 56 mm��yy ��// ,�ma�yf/ QQretard43 mm ��30��m//m,�ma�yf/�fi Finished Ceiling I Finished Ceiling 4-12"/102-305 mm , 4-12"/102-305mm Per NFPA I� Per NFPA Tl F 2"/51 mm 23/8"/60 mm 2"/51 mm 23/8"/60 mm 215/16'% C ��" ��I•i�';`;';J Min Hole Max.Hole I II Min.Hole Max.Hole •, � Finished Surface I I Finished Surface --F I--Typical Wall Typical Wall MAXIMUM EXTENSION MAXIMUM RECESS 'h"Adjustment Recessed–V2709,V2710(drawing not to scale) 15/16'/`V m 24 m I _2 3/16"/ 9/16718 7/16" 5/16" 56mm a ''pp 37mm 37mm Bif AdIMM p Finished Ceiling Finished Ceiling 4-127102-305 mm 4-127102-305 mm ppp Per NFPA I� Per NFPA A J�Ill 2"/51mm 23/8'760mm215/16 (�,: 2"/51mm 23/8"/60mm 1,1 r II��I Min.Hole Max.Hole 75 mm lili Min.Hale Max.Hole Finished Surface I Finished Surface Typical 1 I I Typical Wall !.- Wall MAXIMUM EXTENSION MAXIMUM RECESS 3/4"Adjustment Recessed–V2709,V2710(drawing not to scale) 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. �CtaU�iC victaulic.com 4 A victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Distribution Patterns: Models V2709,V2710 K5.6 Standard Horizontal Sidewall and Recessed Horizontal Sidewall Distribution Patterns-Trajectory i lo' s s 3.Om �4*4% ■■�-'' '. SH. ,?... . ..,..m., ��.,,. .. ,..�.,.�_.. '*4.' _. ... ..w. 7psi -■■-■■. 2.4 m •• I 4• 48 kPa : 4. ' i. 1.8 m ., F;.. ^ .m. • ;. .,. r.. P ' 15 psi 4 ` 103 kPa ;, 1.2 m s I i i �..,... .., :, .., .., .. I .{ ..... ,.... 1--... 30 psi i I I. , i I'. 0,62' m G .. «.. , t 207 kPa I. i i€ 4 z . ..I ._ . ,. 1_, w .. , 0 �_ � 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0,6 m 1,2 m 1,8 m 2.4 m 3.0m 3.7 m 4.3 m 4.9 m 5.5 m 6.1 m 6.7 m 7.3 m 7.9 m Models V2709,V2710 K5.6 Standard and Recessed Horizontal Sidewall Distribution Patterns-Plan View 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6m 1.2m 1.8m 2.4m 3.Om 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 85m j .1 -..'. -, Ii c 2 ; I i 0.6m ' ._-. •' I • • 1.2m • , .. .....•.r • 7psi 6 • _ 1 •_ ' 48 kPa 1.8 m •! : • ._. . 8 i' • 15 psi �� 2.4 m ._ . .._., + .._.. •• �..._.. _ :• 103 kPa -••�••� 10' as►•� • 3.0 m • 30 psi �■■"■■.�■■� r■ .. .. ,.._.. 207 kPa 12' 3.7 m .� 14' ..__.... 3 j 1_.... .R♦ • 4.3m . •.....■.....■..■■.■...■.......■■..■►� 16' 4.9 m NOTES: A. Data shown is approximate and can vary due to differences in installation. B.These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation.Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements.Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. • 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 \Ctaulic' victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.11 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. V27-2 V27 Recessed Open End Temperature—°F/°C No escutcheon ✓ ✓ Maximum With escutcheon / — Sprinkler Victaulic Nominal Ambient Glass TemperaturePart Temperature Temperature Bulb Classification Identification Rating Allowed Color Ordinary A 135°F/57°C 100°F/38°C Orange —'> Ordinary C 155°F/68°C 100°F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/93°C 150°F/65°C Green High J 286°F/141°C 225°F/107°C Blue Extra High 7 K 360°F/182°C 300°F/149°C Purple — M Open — No Bulb 7 Standard response only. • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprin- t klers, before proceeding with installation of any sprinklers. • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove,or adjust any Victaulic piping %11?� products. • Installation rules,especially those governing obstruction, must be strictly followed. • Painting, plating,or any re-coating of sprinklers(other than that supplied by Victaulic) is not allowed. 0 Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. r) Installation Note Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications.All products Installation and Maintenance Sheet for the product you are installing.This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications,designs and standard data,and is available in PDF format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is a registered trademark of Victaulic Company. 40.11 2545 Rev.J Updated 07/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 �ctalul�c FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS A V . A V27, K4.9 ON SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE This Model V27 residential sprinkler is designed to meet the requirements of NFPA 13, 13D °" and 13R for residential use in a variety of room sizes,depending upon available operating pressure and room configuration.The design incorporates state-of-the-art, heat responsive, frangible glass bulb design(quick response)for prompt, precise operation. The die cast frame is more streamlined and attractive than traditional sand cast frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.This sprinkler is available in various finishes to meet many design requirements. PENDENT (V2740) SPRINKLER OPERATION: The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient temperature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. • , COVERAGE: Residential spray coverage up to 20 feet x 20 feet/6.1 m x 6.1 m room sizes per NFPA. TECHNICAL SPECIFICATIONS: Model:V2740 ACCESSORIES Style: Pendent and Recessed Pendent Installation Wrench: Nominal Orifice Size:7A6"/12mm • Open End:V27 , \ K-Factor:4.9 Imp./7.1 S.I.^for room sizes up to • Recessed:V27-1 `'_` /`."_d 20'/6.1 m Sprinkler Finishes: Nominal Thread Size:Y' NPT/15mm • Plain brass Max.Working Pressure: 175 psi/1200 kPa • Chrome plated ` j\ Factory Hydrostatic Test: 100%@ 500 psi/ • White painted** '''..was." ) i 3450 kPa • Custom painted** � Min.Operating Pressure:7psi/48 kPa For escutcheons,cabinets and other accessories ION Temperature Rating:See chart on page 3 refer to separate sheet. 4) _ ^ For K-Factor when pressure is measured in / MATERIAL SPECIFICATIONS Bar, multiply S.I. units by 10.0. J U Pendent Deflector: Bronze per UNS C51000 *Teflon is a registered trademark of Bulb:Glass with glycerin solution Dupont Co. Bulb Nominal Diameter: **UL Listed for corrosion resistance in all 4 Quick Response:3.0mm configurations. Load Screw: Bronze per UNS C65100 NOTE:Weather resistant recessed escutcheon Pip Cap: Bronze per UNS C65100 available upon request. Mir ".� Seal:Teflon*tapeFrame: Die cast brass 65-30 Exaggerated for clarity JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICta'lUI1C® REV E 40.47 1 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4U.41 V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type °F`C Inches Imperial mm 5.1.^ _. ..cUl.us... _. V2740 7/16 12 7.1 Quick ' Pendent 158175 /,e 49 IRecessed Pendent I 155 175 V2740 12 71 Quick Up to 1/2Adjustment 68 79 '/,e 4.9 Recessed Pendent 155,175 V2740 12 71 Quick Up to 3/4'Adjustment# 68,79 #Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10.0. *For 12'x 12'to 20'x 20'rooms #For 12'x 12'to 18'x 18'rooms RATINGS All glass bulbs are rated for temperatures from—67°F/-55°C to those shown in table below. Temperature-"FPC Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color 15Ordinary C 68 100 Red 175 150 --> Intermediate Intermediate E 79 65 ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com ictaulic® VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 4047 2 REV E FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.4/ V27/ K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE WARNING • Always read and understand installation,care,and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. r • Installation rules,especially those governing obstruction, must be strictly followed. • Painting, plating,or any re-coating of sprinklers(other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal 0injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be ry followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone:001-610-559-3300. AVAILABLE WRENCHES Sprinkler Type Open End Recessed V2740 Pendent V27 V27-2 V2740 Recessed Pendent 1 — V27-2 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. Jctaullc REV E 40.47 3 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4V.4/. V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE DIMENSIONS Standard Pendent—V2740 I i nw 23 rn 60 mm 15/a'/ 41 mm , r 11...__A-- 1Ad'/__. 30 mm • Maximum Recess—1/2"Adjustment Recessed—V2740(drawing not to scale) 2'/."/60 mm Max Hole —y 2"/51 mm Min.Hole + --_ Itifittil 17 mm �� I�� Typical Ceiling Tile 3°mm ��Ill-rIPM Typical Ceiling Tile t 13/16'/ �I1'A."/ romf Finished Surface 30 im . Finished Surface 43 mm 1 • MAXIMUM RECESS _ 2%"/ _ 75 mm MAXIMUM EXTENSION Maximum Recess—3/4"Adjustment Recessed—V2740(drawing not to scale) 2'/e^/60 mm _ Max.Hole 2751 mm Min.Hole~ ;'= FAO is46^7 '46� _=— /� 1 37 mm IN 24 mm 18 mm ��I _j Igr Typical Ceiling Tile � I t p I��Typical Ceiling Tile 110 24 ram"6"/ Finished Surface —� Finished Surface 43 mm MAXIMUM RECESS 21sile/ 75 mm MAXIMUM EXTENSION www.victaulic.com �Ctauiic VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV E 40.47 4 it FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 4U.4/ V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE ROOM SIZE Victaulic V2740,4.9 K-Factor Pendent Sprinkler For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Max. Ordinary Temp Intermediate Temp Coverage Rating Rating Deflector to Installation Minimum Areal' 155 /68'C 175`F/79'C Ceiling Type Spacing Flow`•b1 Pressure(°, Flowrbl Pressureeb' Ft.x Ft. GPM PSI GPM PSI Ft, m x m L/min bar L/min bar m 12 X 12 13 7.0 13 7.0 3.7 X 3.7 49.2 0.48 49.2 0.48 14 X 14 13 70 13 7.0 4.3 X 4.3 49.2 0.48 49.2 0.48 3/4"recessed _›. 16 X 16 13 7.0 13 70 Escutcheonlr> 8.0 4.9 X 4.9 49.2 0.48 492 0.48 13/,e to 4 inch or non-recessed 2.4 per NFPA 13,13R 18 X 18 17 12 17 12 or 13D 5.5 X 5.5 64.3 0.83 64.3 0.83 20 X 20 20 16.7 20 16.7 6.1 X 6.1 i 75.7 1.15 75.7 1.15 (a)For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)For NFPA 13 residential applications,the greater of 0.1gpm/ft2 over the design area of the flow in accordance with the criteria in the table must be used. (c) For 20 x 20 Coverage Area-1/2"Maximum Recess www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctaul.c° REV E 40.47 5 4V'4 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS VII//�� J 27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE • NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent recessed pendent(3/a') 13 GPM/49.2LPM-16'x16and'/4.9x4.9mcoverage area 8. 5' 15m t 1,____;_i--- .,„,1, 1 4.,‘„„,..„,,,„;' ' ''''' l--------: i 12m 06M063 ^�" ,„''-'18M 24m 1 8m 12m 0680 R 1. 033 2: LOOM E Model V2740 K4.9 residential pendent and recessed pendent(3/d') 17 GPM/64.3. PM/64.3 LPM 18'x 18'/5.5 x 5.5 m coverage area 8 21m " 1 8m l � - —- -l''''' ''''''' 0 93 0 ,.g,.,w 0.6m 1 6 24m 24m 1.Bm 12m 06m 1 `""'�... s 1 ,-^".",,..� 1 t .," 4 1800 ,.",",.... .w. 03m ,.. '",2' 12m 4OROOM •" See notes on next page. www.victaulic.com �Cta IL! i C VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV E 40.47 6 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4V.4 4. V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE NOMINAL WETTING PATTERNS Model V2740 K4.9 residential pendent and recessed pendent(1/2") 20 GPM/75.7 LPM—20'x 2076.1 x 6.1 m coverage area 8. 7 0.6m3) ,,,,.�-„ 8, m " ^"` 4 186 24m 30m 24m].Bm 72m 06m .v ` 0.3m '"..."-- . i 12m , ' o6m OF ROOM '� NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctaUI1C® REV E 40.47 7 A A FIRE PROTECTION PRO9UCTS-AUTOIVIATIC SPRINKLERS V27, K4.9 Residential Pendent and Recessed Pendent V2740 QUICK RESPONSE • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • For complete contact information,visit www.victaulic.com 40.47 4525 REV E UPDATED 04/2013 I�italL�'ICi VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.47 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS A • • • V27, K5.6UL Fnn ® PCB �I��' 0 SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE ., °:` MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications.They are available with either standard or quick response bulbs.The design incorporates ' ,, state-of-the-art, heat responsive,frangible glass bulb design(standard or quick response)for prompt, precise operation. UPRIGHT PENDENT RECESSED (V2703 AND (V2707 AND PENDENT The die cast frame is more streamlined and attractive than traditional sand cast v2704) v2708) 012707 AND v27os) frames. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort.This sprinkler is available in various temperature ratings(see chart on page 2)and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides up to 3/4719 mm of adjustments. ' SPRINKLER OPERATION The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire,the ambient temperature rises causing the liquid in the bulb to expand.When the ambient tem- perature reaches the rated temperature of the sprinkler,the bulb shatters.As a result,the waterway is cleared of all sealing parts and water is discharged towards the deflector.The deflector is designed to distribute the water in a pattern that is most effective in controlling the fire. COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. • TECHNICAL SPECIFICATIONS Models/S.I.N.:V2703,V2704,V2707,V2708 Style: Pendent, Upright or Recessed Pendent ACCESSORIES • (Di Nominal Orifi• ce Size: 1/2"/13 mm • K-Factor:5.61mp./8.1 S.I.^ Installation Wrench: Nominal Thread Size: 1h" NPT/15mm • Open End:V27 • Max.Working Pressure: Recessed:V27-2 175psi/1200kPa FM Global Finishes: 0 250 psi/1725kPa ULPlain brass • Factory Hydrostatic Test: • Chrome plated 100% @ 500psi/3450kPa • White painted** \ Min.Operating Pressure:7 psi/48 kPa • Black painted** • Temperature Rating:See charts on page 2&3. Custom painted** �,� • Proprietary nickel Teflon*coating** MATERIAL SPECIFICATIONS • For 155,200,and 286°F Standard ,40 1.--k. `� Response Only,wax coated** a Upright Deflector: Bronze per UNS C22000 `� Pendent Deflector: Bronze per UNS C51000 For cabinets and other accessories refer to Bulb:Glass with glycerin solution. separate sheet. M, Bulb Nominal Diameter: NOTE:Weather resistant recessed escutcheons Standard:5.0 mm available upon request. • Quick Response:3.0mm Load Screw: Bronze per UNS C65100 A For K-Factor when pressure is measured in Pip Cap: Bronze per UNS C65100 Bar, multiply S.I. units by 10.0. Spring: Beryllium nickel * Teflon is a registered trademark of Dupont Co. Exaggerated for clarity Seal:Teflon*tape **UL Listed for corrosion resistance in all Frame: Die cast brass 65-30 configurations. Lodgement Spring:Stainless steel per UNS S30200 `JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. IlctaUlilc' REV I 40.10 1 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40. 1U ' V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE APPROVALS/LISTINGS Model V2703 V2707 V2707 V2704 i V2708 V2708 Orifice Size(inches) i Y2" 4 Yz /z" 1/2 Y2 Yz" Orifice Size(mm) 13 13 i 1313 13 13 } Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5 6 Nominal K Factor S I 8 81 81 81 81 81 Response I Standard Standard Standard i Quick Quick Quick ' Recessed 9 Recessed Deflector Type Upright Pendent Upright Pendent IPendent Pendent Adjustment up to 3/a' up to 34" Approved Temperature Ratings F/C by Agency$ Model 135°F/57°C 135°F/57°C135°F/S7°C 135°F/57°C 135°F/57°C 155°F/68°C i 155°F/68°C135°F/57°C 155°F/68°C 155°F/68°C I 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C UL 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C i 286°F/141°C i 286°F/141°C 286°F/141°C200°F/93°C 360°F/182°C 360°F/182°C E 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C155°F/68°C ULC 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F1141 C 286 F/141°C 1 286°F/141°C 360 F/182°C 360 F/182°C 135°F/57°C 35°F/57°C135°F/57 C ` 135°F/57°C 155°F/68°C i 155°F/68°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C FM# i 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°CE 175°F/79°C 200°F/93°C I 200°F/93°C 286°F/141°C 1 286°F/141°C 200°F/93°C200°F/93°C 286°F/141°C ? 286°F/141°C 360 F/182°C I 360 F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C NYC/MEA#62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93 C175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C i i 360°F/182°C ' 360°F/182°C 35°F/57°C 135°F/57°C 135°F/57°C 135 F/57°C 135°F/57°C 155°F/68°C 155°F/68 C135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 175°F/79°C175°F/79°C 155°F/68°C CSFM#7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C I 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C i 286°F/141°C `- 135°F/57°C i 135°F/57°C 155°F/68°C 135°F/57°C 155°F/68°C i 135°F/57°C LPCB 175°F/79°C 175°F/79°C 175°F/79°C i 175°F/79°C None None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C 135°F/57°C 135°F/57°C1 35°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C VNIIPO 175F/79C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79 C 175°F/79°C 200°F/93°C 200°F/93°C i286°F/141°C 286°F/141°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C . _ 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTX 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C CCCNone None i 200°F/93°C 200°F/93°C i 200°F/93°C 200°F/93°C I1 E I i 1 #Listings and Approvals as of printing.All are approved open,except for areas designated"No". ^For K Factor when pressure is measured in Bar,multiply S.I.units by 10.0 #FM Approved with 1/2"adjustment escutcheon only-quick response www.victaulic.com iCtaUliC® VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 2 REV I FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature-°F/°C Victaulic Sprinkler Temperature Part Nominal Temperature Maximum Ambient Classification Identification Rating Temperature Allowed Glass Bulb Color Ordinary A 135 100 Orange 57 38 Ordinary G 155 100 Red 68 38 Intermediate 175 150 Yellow 79 65 200 150 Intermediate F 93 65 Green High 286 225- ; Blue 141 107 Extra High$ K 360 300 Purple 182 149 ` Open — No Bulb Standard response only. All are approved open,except for areas designated"No". —150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Thread Size Quantity Sprinkler Finish Escutcheon Finish Wrench Model Number www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt.'alulll^.® REV I 40.10 3 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40. /U V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE WARNING • Always read and understand installation,care,and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. • Installation rules,especially those governing obstruction, must be strictly followed. 0 • Painting, plating,or any re-coating of sprinklers(other than that sup- plied by Victaulic)is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association document NFPA 25 that describes care and maintenance — of sprinkler systems. In addition,the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that n, mustbe followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone: 001-610-559-3300. DIMENSIONS Standard Pendent—V2707,V2708 Standard Upright—V2703,V2704 f 17/6"/ i 37 mm ES 1 it .rW z3ie°/ -r- f 60 mm 1%"/ 1 s/s"/ 41 mm 41 mm !Ili011:11 2/s/ iiimilli � 60 mm 1'Y 111•1-- 25 mm '/i'Adjustment Recessed—V2707,V2708(drawing not to scale) 2W/60"/60 mm Max.Hole 2"/51 mm r—Min.Hole 1I lat=itall 1 fid/ 1/'c m �jy LL,®`am�� Typical Ceiling Tile ��lr iilla��30 I 1',A6"/ Finished Surface 30 m 43 mm _ I MAXIMUM RECESS 2'H6"/ 75 mm MAXIMUM EXTENSION www.victaulic.com �Cta ulid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 4 REV I • FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4U. 1 U Y 27, K .6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DIMENSIONS 3/4"Adjustment Recessed—V2707, V2708(drawing not to scale) 2 "/60 mm Max.Hole 2"/51 mm Min.Hole ,„F/ ,,A"/ 24mm "7e"/ �� A//� TypicalCeiling ��,����,�� 37i m 18 mm ,ally, /lam Tile QY/1---1- f 11, •���'�� Finished Surface 24 mm MAXIMUM RECESS 2'SU/ 75 mm MAXIMUM EXTENSION AVAILABLE WRENCHES Sprinkler Type V27-2 Recessed V27 Open End V2707,V2708 Pendent yes yes V2707 V2708 Recessed Pendent yes — V2703,V2704 Upright yes yes DISTRIBUTION PATTERNS Models/S.I.N.V2707,V2708 K5.6 standard pendent and recessed pendent distribution patterns—trajectory 10' I 44.s. , w.n 8 ` ♦`♦♦♦ 2.4m .._.,.._ 1.... W._._..,... +`.. ..�.. y r . ...n.. '♦� 4♦ 44. I . 6 ♦ c 1.8m R.�... ..,..�. _. ,... • ♦ i r : • 4 e `♦ ♦♦I I ,. 1.2mF € j i ♦, z' I ♦♦♦ I I I I ♦ �_. ♦♦ I i tt ♦i _. v ♦ 4 I2 4 6' 8' 10' 12' 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7 psi •••".'••• 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on next page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctaul.c REV I 4010 5 FIRE PROTE.CTION PRODUCTS-AUTO VIATJC SPRINKLERS , - �' V27, K5.6 Standard Spray; Upright, Pendent and Recessed Pendent MODELS/S.I.N.V2703 AND V2707 STANDARD RESPONSE MODELS/S.I.N.V2704 AND V2708 QUICK RESPONSE DISTRIBUTION PATTERNS Models/S.I.N.V2703,V2704 K5.6 standard upright distribution patterns—trajectory 10 —.. —._ E ,.-f 3.0LLLLLL777777 •_ m�' • � �� I r . 2.4m • .4 4 c I I I acv *4.1 I '• ; ♦ E • t � • ,i I r .. 0.6m 1 j yL A i i ♦♦ `:. . � 4 �w ,1 1, " L,� ..k.. ,. .,.�...h...,,-.,. ..:... ..,,...,,,..{ 2' 4'.. 6'' $ 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 4.9m 7 psi "•"' 15 psi 30 psi 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the perfor- mance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 40.10 2544 REV I UPDATED 04/2012 ICtc�llIiri VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.10 FIRE_PROTECTION P$QDUCTS AUTOMATIC SPRINKLERS . S II V36, K5.6 0 ® c LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall ....._..... (iv -, .,tr, itt, -/, i .r. ,,, V3609 STANDARD RESPONSE " I V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL fiCtIE .. 41,7 . EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL The V36 dry Sprinkler is used in'special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary horizontal pipe nipples. The Model V36 Dry Type Horizontal Sidewall Sprinkler utilizes a frangible glass bulb.At the bulb's rated temperature,the sprinkler opens releasing the bulb seat assembly,causing the inner tube assembly to move,allowing the spring assembly to pivot alongside the inner tube.At this time,water flows through the sprinkler and is distributed by the deflector, in an approved discharge pattern. The heart of the Model V36 sprinkler's proven actuating assembly is a hermetically sealed frangible glass bulb that contains a precisely measured amount of fluid.When heat is absorbed,the liquid within the bulb expands increasing the internal pressure.At the prescribed temperature the internal pressure within the bulb exceeds the strength of the glass causing the glass to shatter.This results in water discharge which is distributed in an approved pattern. COVERAGE: For coverage area and sprinkler placement, refer to NFPA 13 standards. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Ctaul1C REV I 40.64 1 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4U•b4 • V36, K5.6 ® ® c LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall °l, ' li , ... ,1I r_jr,'.' V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL _, 41,. -411 EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL TECHNICAL SPECIFICATIONS: ' rY.�r.Y.yis�•sis�•sisis�•s�iys�.s1� 111 M� 11.2L4-\ wds, jY/i���, �a�.-\`1►�' �I ertY.4ii�ii/�irAWAFAriiriYyiYl��� mil I Exaggerated for clarity Models:V3610 and V3609 ACCESSORIES Style: Horizontal Sidewall and Recessed Installation Wrench: Model V36 Open End and Horizontal Sidewall Recessed Wrenches fit all V36 Series frames. Nominal Orifice Size: '/z"/13mm Finishes: Orifice Insert:Stainless steel per UNS S30300 • Plain brass K-Factor:5.6 Imp./8,1 S.I.° • Chrome plated° Nominal Thread Size: 1" NPT/33.7mm • White Painted° Max.Working Pressure: 175 psi/1200 kPa • Flat black painted° Factory Hydrostatic Test: 100%@ 500 psi/ • Custom painted° 3450kPa • Wax° Min.Operating Pressure:7psi/48kPa • Proprietary Nickel Teflon*Coated° Temperature Rating:See chart on page 3. For cabinets and other accessories refer to separate sheet. MATERIAL SPECIFICATIONS A For K-Factor when pressure is measured in Deflector: Brass per UNS C22000 or Stainless Bar, multiply S.I. units by 10.0. Steel per UNS S30400 * Teflon is a registered trademark of Dupont Co. Bulb:Glass with glycerin solution ° UL Listed for corrosion resistance in all con- • Standard: 5.0 mm figurations. • Quick Response:3.0mm NOTES: Split Spacer:Stainless steel per UNS S30300 1.Weather resistant escutcheon available upon Load Screw: Brass per UNS C36000 request. Pip Cap:Stainless steel per UNS S30300 2.Only the Plain Brass and Nickel Teflon Spring Seal Assembly:Teflon*coated Beryllium finishes are FM approved. nickel alloy and Stainless steel per UNS S30300 Frame: Die cast brass Outer Tube:Galvanized steel pipe Inner Tube:Stainless steel per UNS S30400 Escutcheon: 1010- 1018 mild steel and Stainless Steel Torsion Spring:Stainless Steel Wire www.victaulic.com '.Cta u I i c VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV I 40.64 2 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 4U.b4 1136, K5.6 0 <> CO LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall Fin` ,.,, l> V3609 STANDARD RESPONSE �a` .-= 4 � ��; V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL �1 . . ,J f 1 EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL APPROVALS/LISTINGS Orifice Nominal Approved Temperature Ratings Model Size K-Factor Response Deflector Type "F/C 1"+ Inches Imperial Standard mm S.I^ or Quick UL* C-UL* FM -› V3610 Yz 5.6 Quick I Horizontal Sidewall ;135,155 200,286 135,155,200,286 135,155,200,286 13 8.1 ; 57,68,93,141 57,68,93,141 57,68,93,141 V3610 Yz 5.6 Recessed Horizontal 135,155,200,2861 135,155,200,286 135,155,200 13 8.1 Quick Sidewall i 57,68,93,141 ,, 57,68,93,141 57,68,93 V3609 /z 5.6 Standard Horizontal Sidewall 135,155,200,286 135,155,200,286 i 135,155,200,286 13 8.1 } 57,68,93,141 57,68,93,141 57,68,93,141 V3609 ._ .. 5Standard 135,155,200_... /z 5.6,6 Recessed Horizontal?135,155,200,286 135,155,200,286 13 8.1 Sidewall 57,68,93,141 57,68,93,141 ; 57,68,93 *Listings and approval as of printing. A For K-Factor when pressure is measured in Bar,multiply S.I.units by 10. *Light Hazard Only-Listed for light hazard only with deflector from 4"-12"below the ceiling. **Approved for V3609 and V3610 up to 48"length. RATINGS All glass bulbs are rated for temperatures from-67°F/-55°C to those shown in table below. Temperature-'Fr Sprinkler Temperature Nominal Temperature Maximum Ambient Classification Rating Temperature Allowed Glass Bulb Color Ordinary 135/155 100 Orange/Red 57/68 38 Intermediate 930 650 1 Green Hi h 286 225 9 141 1 107 Blue • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaUI1C° REV I 40-64 3 FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.b4 . V365.6 0 ® CO LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL 41111:E.4 4 ��i4i EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL ORDERING INFORMATION Please specify the following when ordering: Sprinkler Model Number Style Temperature Rating K-Factor Quantity Sprinkler Finish Escutcheon Style "A"Dimension-Distance from face of fitting to the finished ceiling line regardless of escutcheon used AVAILABLE WRENCHES Model V36 Open End and Recessed Wrenches fit all V36 Series frames. ff. www.victaulic.com iCtaUlilC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.64 4 REV I FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.b4 36, K5.6 ® ® cO LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall 4.T 114 —101 01110 V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL alltwo4 �t- i EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL WARNING • Always read and understand installation,care,and maintenance instructions,supplied with each box of sprinklers, before proceeding with installation of any sprinklers. c • Always wear safety glasses and foot protection. • Depressurize and drain the piping system before attempting to install, remove,or adjust any Victaulic piping products. %1Pb • Installation rules,especially those governing obstruction, must be strictly followed. • Painting, plating,or any re-coating of sprinklers(other than that sup- 0 plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition,the authority having jurisdiction may have addi- tional maintenance,testing,and inspection requirements that must be tl ri followed. If you need additional copies of this publication,or if you have any questions about the safe installation of this product,contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA,Telephone:001-610-559-3300. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt aul.C® REV I 40.64 5 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 40.b4 w V36, K5.6 FM CLI STED , Dry Type Standard Spray, Light Hazard Horizontal Sidewall and •` Recessed Horizontal Sidewall /tf - „, _.r.........,.. Y �� .. . . ....„,,, .......44 *al 7 — V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL '41111.184 II ;.. Wim; .,{111 I. EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DIMENSIONS NOTE:The"A"dimension of a dry sprinkler,which extends into a freezer from a wet piping system, must take into account the wall or ceiling thickness of the freezer.See IMPORTANT INSTALLATION INFORMATION later in this document. q. (Min1W1 -I (Min.1W) —HI r 1/2I Two Piece Escutcheon 'NPT , I III I� �I ��I I'� eicil t 11/2'Min DI. I-'- 116'Min DI Tee with sa to outlet size Hole In Wall 3'Dia Tee with sate outletsize Hole in Wall as sprinkler thread slzeas sprinkler thread size See IMPORTANT INSTALLATION 2'A. See IMPORTANT INSTALLATION / 4'n3^'MMinax. INFORMATION later in this document. / INFORMATION later in this document. / Flush T I1 Sleeve&Skin Al (Met l'1/2") /1"NPT : ‹. j Tee with sate outlet tee She as sprinkler thread see See IMPORTANT INSTALLATION INFORMATION later in the document Plain Basset .q, (fAin.Iia') 1"NPT Hole in nWall ` Wall Cup Hole�n Wall ----- it- �; I"NPT I` C ',I I� /moi 3,',i,'; _ * 1 r' .�� _____I t \` l i �i= Dia. Tee with same outlet size \ \I as sprinkler thread size Two Piece -- -�I 2'Min.Dia. See IMPORTANT Escutcheon t Hole In Wall INSTALLATION Tee with same outlet size INFORMATION later in \ as sprinkler thread size \ 1Ve"MaMinx.-' this document. IMPORTANT INSTALLATION 2'h" •q• a"Min. INFORMATION later in the document. (Min t%'7 5Y='Max. Extended Recessed DEFLECTOR TO CEILING DISTANCE 4-12"/102-305MM FOR ALL CONFIGURATIONS SHOWN ABOVE. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt9UIiC 40.64 6 REV I FIRE PROTECTION PRODUCTS-AUTOMATIC SPRINKLERS 40.b4 Y36, K5.6 0 ® c O LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall ;x ,r,. ;_ 111111111°14 V3609 STANDARD RESPONSE f "1. :., V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL it .. {; n{ EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS MODELS V3610,V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS-TRAJECTORY 10' x. ••:■.�..� 3.0m •�,' '••• 8' •� i • , .� ' ... ..• r�� wr m 6' 1 4' *i •• 2' k............. • . • 0.6 m i-. ,- ... -w.. ,.. s I, , 4 .1 . •• 0 ". . .. .. . .. .. .,M! 1 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 0.6m 1.2m 1.8m 2.4m 3.Om 3.7m 4.3m 4.9m 5.5m 6.1 m 6.7m 7.3m 7.9m 7 psi 15 psi ... .. .,. 30 psi • 48 kPa 103 kPa 207 kPa MODELS V3610,V3609 HORIZONTAL SIDEWALL AND RECESSED HORIZONTAL SIDEWALL DISTRIBUTION PATTERNS-PLAN VIEW 2' 4' 6' 8' 10' 12' 14' 16' 18' 20' 22' 24' 26' 28' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m 4.9 m 5.5 m 6.1 m 6.7 m 7.3 m 7.9 m 8.5 m 2 ; I k € ". j i 0.6 m 1 ... .gym. 4 I I • i • I 1.2m � I 6' - i I ' t 8' �� * I b •• - . •. . I _ I. 2.4 m � . . I ; ' i•jo 1 i 10'3.Om •• ,.�, , v �, � 0 I 3.7m y.,,.r i i,..... I. s,. 14' ♦• �. e , ' k �: 16' { 4.9 m 7psi -••-•. 15 psi 30 psi 48 kPa 103 kPa 207 kPa See notes on last page. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaulic' REV I 40.64 7 FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERS 4U■b4 '2 V36, K5.6 0 ® COLI Dry Type Standard Spray, Light Hazard Horizontal Sidewall ands. Recessed Horizontal Sidewall .it x t ' gr,— ' I °' V3609 STANDARD RESPONSE _1k. ,4I" v V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL IMPORTANT INSTALLATION INFORMATION For detailed installation instructions,see publication 1-40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13.These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible,the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. No. 2 Dry sprinklers MUST be installed only into the outlet of a cast or malleable iron tee. No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT install dry sprinklers into any fitting that interferes with thread penetration. NOTE:The end seal of the dry sprinkler MUST NOT bottom out in the fitting. M m NOTE:The "A"dimension of a dry sprinkler,which extends into a End Seal freezer from a wet piping system, must take into account the wall or HEATED SPACE WIC fA ceiling thickness of the freezer.The minimum length of the dry sprinkler 0moi should not be less than the lengths specified in the following table, plus 1 the thickness of the freezer's wall or ceiling("A"="C" +"D"). "C"Exposed Minimum Barrel Refer to the drawing for a representation of the"A"dimension. DO NOT Length(Refer to Table) Diameter of hole is dependent upon the type of escutcheon selected.Space must attempt to modify dry sprinklers,since they are manufactured to this I be sealed to prevent condensation from Specific"A"dimension, _ forming,per NFPA requirements. The following table is used when the ambient temperature is maintained "A" - between 40°F/4°C and 60°F/16°C around the wet piping system. See Note - EXPOSED BARREL AMBIENT TEMPERATURE(°F/°C) Insulation Exposed Minimum Barrel Length Ambient Temperature inches/mm Exposed to Discharge l End of Sprinkler 40°F/4`C 50°F/10°C ( 60°F/16°C ' F/`C III 0 v(,-:;'-',./,',. Wall or Ceiling of Freezer 40 0 .', _-',-,H 4 0 0o 0 30 0 0 0 o mini 20 - 4 0 0 1111911 -7 COLD SPACE 10 102 .._.....__ 0..___ 0 8 1 -12 203 25 0 Exaggerated for Clarity 0 12 3 0 -18 305 76 ! 0 TYPICAL SLEEVE AND SKIRT CONFIGURATION FOR EXAMPLE ONLY 10 14 4 1 -23 I 356 102 25 -20_ i 14 6 3 -29 356 152 . 76 -30 16 8 4 -34 406 203 102 -40 18 8 I 4 -40 457 203 102 -50 20 10 6 -46 508 254 152 -60 I 20 10 6 -51 508 254 152 NOTE:Exposed minimum barrel lengths are inclusive up to 30-mph/48-kph wind velocities www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICt.'caUI1C 40-64 6 REV I FIRE PROTECTION PRODUCTS—AUTOMATIC SPRINKLERSr. A • A V36, K5.6 0 ® 0O LISTED Dry Type Standard Spray, Light Hazard Horizontal Sidewall and Recessed Horizontal Sidewall .t -40 Ountl V3609 STANDARD RESPONSE V3610 QUICK RESPONSE FLUSH DRY RECESSED DRY SLEEVE&SKIRT HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL 411110111114 EXTENDED PLAIN HORIZONTAL SIDEWALL HORIZONTAL SIDEWALL NOTES 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories,floor-wetting,and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers.They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin- kler spacing rules for installation. Refer to the appropriate NFPA National Fire Code and the Authority Having Jurisdiction for specific information regarding obstructions,spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings,Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • US&WORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905-884-7444 1-610-559-3300 Easton, PA 18044-0031 USA 905-884-9774(fax) 1-610-559-3608(fax) 4901 Kesslersville Road viccanada@victaulic.com vical@victaulic.com Easton, PA 18040 USA EUROPE ASIA PACIFIC 1-800-PICK-VIC(1-800-742-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38(fax) 86-21-54253671 (fax) 1-610-250-8817(fax) viceuro@victaulic.be vicap@victaulic.com pickvic@victaulic.com UNITED KINGDOM MIDDLE EAST www.victaulic.com 44(0) 1438310690 971-4-883-88-70 44(0) 1438310699 (fax) 971-4-883-88-60(fax) viceuro@victaulic.be UPDATED 12/2009 40.64 3127 REV I ictaulic® VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2009 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 40.64 • Bulletin 016 Rev.E Model DH56 HSW p0 Reliabl ® Model DH56 HSW Recessed Model DH56 HSW Concealed Quick Response, Extended Coverage Dry Sprinklers rn For coverages up to 28 feet wide and 10 feet long(1). 250 psi (17,2 bar) rated. Features: ; . ► 1. Coverage for long and narrow spaces such as hall- �� ! ways, corridors, decks and rooms up to 28 feet wide and 10 feet long.11 2. Deflector to ceiling dimensions are: 4"(102mm)min.to 12"(305mm)max. DH56 HSW 3. Minimum spacing between sprinklers 13 feet (4m).(1) 4. Polyester Coated Corrosion Resistant Sprinklers(cULus) 5. UL Listed for extended coverage, light hazard appli- ,,, cations. 6. 5.6 K Factor. 7. Sprinkler is approved for 250 psi(17,2 bar)applications. 8. Quick response performance. 9. 1" (13mm) adjustment of escutcheon and cover. 10.Concealed cover plate can prevent the sprinkler from w' being used for unintended purposes. No exposed thermal element with the concealed version. DH56 HSW FP Recessed 11.Push-on/thread-off sturdy convenient escutcheon for recessed and cover for concealed. 12.Factory assembled sprinkler&cup, shipped complete • with bulb protector for concealed and FP recessed ver- sions. 13.Sprinkler&cup assembly and escutcheon or cover are separately packaged. 14.Cover finishes available in standard white paint, spe- cial bronze, black paint or flat white paint. DH56 HSW Concealed (1)See Fig. 7. with SWC coverplate Approval Organizations a fire the rising ambient temperature melts the solder and 1. Listed by Underwriters Laboratories Inc. and the cover plate is ejected away by springs exposing the UL certified for Canada(cULus) 3mm frangible glass bulb. The use of a 3mm bulb allows 2. NYC MEA 258-93-E quick response which enables the sprinkler to apply water to a fire sooner than standard response sprinklers of the Products Description same temperature rating. The Model DH56 are quick response extended coverage Model DH56 dry sprinklers are intended for use in dry sidewall dry sprinklers for use in light hazard applications. and preaction systems to protect areas subjected to freez- The Model DH56 dry sprinkler with SWC cover plate is a ing temperatures and unheated portions inside buildings. concealed sprinkler that uses Reliable's push on/thread off See Fig. 1 for guidelines on using dry sprinklers in wet sidewall cover. This sprinkler has the cup factory mounted systems. and is shipped with a bulb protector that protects the 3mm Environments wherein dry sprinklers are employed can frangible glass bulb during shipping and post installation be corrosive. For this reason, Model DH56 dry sprinklers finishing operations. The DH56 can be combined in the have a special wax fillet placed in the gap between the field with the FP or F2 Escutcheon to make a recessed cup that supports the bulb and the wrenching boss. This dry sprinkler. The SWC cover plate, FP and F2 recessed wax will not interfere with the operation of the sprinkler,and escutcheons have 1/2" adjustment. The SWC cover plate it prevents contaminants from entering the internal portion is attached with 135 & 165 degree solder. In the event of of the drop nipple. The wax must not be removed. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application DH56 HSW Concealed with SWC Cover Plate The Model DH56 is a horizontal sidewall dry sprinkler To install the DH56 HSW dry sprinkler with the SWC intended for installation in light hazard occupancies in ac- coverplate as a concealed sprinkler, cut a 21/8" diam- cordance with NFPA 13. These sprinklers are designed to eter hole into the wall as shown in Fig. 6. Temporari- provide fire protection in long and narrow spaces such as ly remove the plastic protective cap, and then use the hallways, corridors, decks and rooms up to 28 feet (8,5m) Model XLO2 wrench (see Fig. 2) to tighten the sprinkler wide and 10 feet(3m)long. They are rated for 250 psi(17,2 until it is secured in the sprinkler fitting. Note: The Model bar) and can be mounted between 4 and 12 inches (102 XLO2 wrench has a notch in it to accommodate the de- and 305mm)down from the ceiling. flector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during General Installation Instructions tightening.Apply a Teflon**based sealant to the sprinkler Model DH56 dry sprinklers must be installed only in stan- threads before installing in the sprinkler. Wrench only on dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) the square boss. DO NOT WRENCH ON ANY OTHER pipe tees in the horizontal position,even at branch line ends. PART OF THE SPRINKLER. It is recommended that the They should not be installed into elbows or pipe couplings sprinkler be protected during plastering and painting op- located on drop nipples to the sprinklers. For these and erations by reinstalling the plastic protective cap. Instal- other fittings including CPVC, the dry sprinkler should be lation is completed by removing the protective cap and installed into a fitting to allow protrusion into the fitting in ac- inserting the coverplate. Coverplate assemblies provide cordance with the diagrams. The "A" dimension of the dry ��2" (13mm) of adjustment. Final adjustment is made by sprinkler, which extends into a freezing zone from wet pipe turning the coverplate clockwise until the skirt flange systems, should be selected to provide, as a minimum, the makes full contact with the wall surface. Cover removal specified lengths in inches shown in Fig. 1. requires turning in the counter-clockwise direction. Caution: Concealed coverplate assemblies are listed only for Do not install Model DH56 HSW Dry sprinklers into CPVC use with specific sprinklers. The use of any other con- adapter fittings or tees that have an internal obstruction. cealed wall sprinkler or the use of the SWC coverplate This will damage the sprinkler and/or the fitting. Refer to on any sprinkler with which it is not specifically listed will Fig. 8 void all guarantees, warranties, listings and approvals. DH56 HSW Note: DH56 and DH56 Recessed Sprinklers have or- To install the DH56 HSW dry sprinkler cut a 21/8" diameter ange bulb protectors to minimize bulb damage during PRO- hole in the wall as shown in Fig. 4. Use the Model G3 instal- shipping, handling, and installation. REMOVE THIS lation wrench (see Fig. 3) to tighten the sprinkler until it is TECTION AT THE TIME THE SPRINKLER SYSTEM IS Remov- secured in the sprinkler fitting. Apply a Teflon* based seal- PLACED IN SERVICE FOR FIRE PROTECTION.ant to the sprinkler threads before installing in the sprinkler. al of the protectors before this time may leave the bulb Wrench only on the square boss. DO NOT WRENCH ON vulnerable to damage. RASCO wrenches are designed ANY OTHER PART OF THE SPRINKLER. Installation is com- to install sprinklers when covers are in place. REMOVE pleted by removing the orange glass bulb-protector and as- PROTECTORS BY UNDOING THE CLASP BY HAND. DO sembling the slip-on escutcheon to the sprinkler's can. NOT USE TOOLS TO REMOVE THE PROTECTORS. DH56 HSW Recessed with FP Escutcheon To install the DH56 HSW dry sprinkler with the FP Escutch- eon as a recessed sprinkler cut a 25/8" diameter hole in the wall as shown in Fig.5. Temporarily remove the plastic pro- tective cap, and then use the Model XLO2 wrench(see Fig. 2) to tighten the sprinkler until it is secured in the sprinkler fitting. Note: The Model XLO2 wrench has a notch in it to accommodate the deflector top. This wrench can only be inserted one way. Care must be taken not to damage the deflector during tightening. Apply a Teflon** based seal- ant to the sprinkler threads before installing in the sprinkler. Wrench only on the square boss. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. It is recommended that the sprinkler be protected during plastering and paint- ing operations by reinstalling the plastic protective cap. In- stallation is completed by removing the protective cap and inserting the push-on escutcheon. Turn clockwise to adjust the escutcheon against the wall. "DuPont Registered Trademark 2. • RECOMMENDED MINIMUM EXPOSED BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA (STANDARD DH56 HSW DRY SPRINKLER SHOWN) EXPOSED BARREL AMBIENT AMBIENT TEMPERATURE TEMPERATURE OF PROTECTED 40'F/4'C 150'F/10'C 0 60'715'C AREA* AT THE DISCHARGE END EXPOSED MINIMUM BARREL LENGTH** Of THE SPRINKLER (FACE OF TEE TO TOP OF CEILING) N. (MM) N. (MM) N. (MM) 407 (4'C) 0 0 0 30'F (-1'C) 0 0 0 20'F(-TC) 4 (101) 0 0 "A° 10'F (-12'C B (203) 1 (25.1) 0 DIMENSION 0'F (-l8'C) 12 (305) 3 (75) 0 MINIMUM CLEARANCEHOLE POSED -10'F (-23'C) 14 (356) 4 (101) 1 (25.1) BARREL LENGTH -20'F(-29'C) 14 (356) 6 (152) 3 (75) ESCUTCHEON' -30'F (-34°C) 16 (406) S (203) 4(101) / / 1 -40'F(-40'C) 18 (457) 8 (203) 4 (101) (HEATED AREA) -50'F (-46 c) 20 (Doa) 10 (254) 6 (152) -NSF (-arc) 20 (NOB U (2NA) N (152) * THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING. `+- MIS _ _ _ _ _ _ 'III 10i4 3" THE AMBIENT TEMPERATURE IS THE TEMPERATURE AT THE DISCHARGE \6;- r i II I%III DIA' END OF THE SPRINKLER. u FOR PROTECTED AREA TEMPERATURES THAT OCCUR BEPNEEN THE VALUES '`'1 -z----- ‘-_- Nmil LISTED, USE THE NEXT COOLER TEMPERATURE414. **THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE 'A' DIMENSION. WET NOTE. EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP TO 30MPH PIPE (PROTECTED AREA) WIND VELOCITIES IN THE PROTECTED AREA. INSTALL 1 INCH NPT THREADED END OF DRY PENDENT SPRINKLER i 1\ INTO THE 1 INCH NPT SIDE OUTLET OF A MALLEABLE IRON TEE FITTING PER ANSI B 163 (CLASS 150) WALL OR CAST IRON THREADED TEE FITTING PER ANSI 16.4(CLASS 125) ONLY. INSULATED FREEZER OR COOLER STRUCTURE OR EXTERIOR FRAMING IF HUMIDITY AND TEMPERATURE DIFFERENTIAL CAUSES CONDENSATION ON THE EXPOSED DRY SPRINKLER, CONSIDER WRAPPING THE EXPOSED BARREL WITH INSULATION, FOAM INSULATING TAPE OR EQUIVALENT, SEAL THE CLEARANCE SPACE AROUND THE SPRINKLER TO AVOID LEAKAGE OF AIR INTO THE PROTECTED AREA AND CONSEQUENT FORMATION OF CONDENSATE AROUND THE FRAME, WHICH COULD INHIBIT OPERATION OR CAUSE PREMATURE OPERATION-SEE BELOW FOR RECOMMENDED METHODS. RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS (STANDARD DH56 HSW DRY SPRINKLER SHOWN) MINIMUM EXPOSED CLEARANCE MINIMUM BARREL HOLE — EXPOSED LENGTH BARREL (SEE ABOVE) LENGTH (SEE ABOVE) INSIDE INSIDE FACE ...„ % DRY SPRINKLER FACE DRY SPRINKLER IN COLD AREAIMO IN COLD AREA (HEATED AREA/ (HEATED AREA) IIIJ �IIIiIIiIr; /II�Iq 1 ill AL (PROTECTED AREA/ DECKTITE FLASHING RASCO #4003910 (RECOMMENDED) INSULATED FREEZER, OR COOLER STRUCTURE OR EXTERIOR FRAMING PI NF005* Fig. 1 3. - Technical Data: Maintenance K Factor Temperature Sprinkler Model DH56 Quick Response Dry Sprinklers should be Thread Rating Maximum Identification inspected quarterly and the sprinkler system maintained in Size SWC Ambient Number accordance with NFPA 25. Do not remove the factorya US Metric Sprinkler Cover Temperature (SIN) p plied thermally sensitive wax fillet between the bulb support- 155°F 135°F 100°F ing cup and the wrenching boss. Do not replace this wax with (68°C) (57°C) (38°C) a substitute substance. An alternate substance may interfere 5.6 80 1 175°F 165°F 150°F with proper operation of the sprinkler. Do not clean sprinklers (79°C) (74°C) (66°C) RA1664 with soap and water, ammonia or any other cleaning fluids. 200°F 165°F 150°F Remove dust by using a soft brush or gentle vacuuming. Re- (93°C) (74°C) (66°C) move any sprinkler which has been painted(other than factory applied)or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- Coverage Area aged or operated sprinklers. Prior to installation, sprinklers Maximum Coverage Flow Rate pressure should be maintained in their original cartons and packaging Area Width x Length gpm(L/min) psi(bar) ft x ft(m x m) until used to minimize the potential for damage to sprinklers 28 x 8(8,5 x 2,4) 23(87,1) 16.9(1,2) that would cause improper operation or non-operation. 28 x 10(8,5 x 3) 28(106) 25(1,7) Model DH56 Quick Response Approval Type: Extended Coverage Horizontal • Quick Response, Extended Coverage. Sidewall Dry Sprinkler Specification • Approved for installation in accordance with NFPA 13 Sprinklers shall be a [quick response- cULus Listed] ex- for light hazard occupancies. tended coverage horizontal sidewall sprinkler for light hazard occupancies. Sprinklers to be of bronze frame construction Step 1 with a special deflector capable of providing a discharge over -- a coverage area of 28 ft. (8,5m) wide, and 10 ft. (3m) long , . horizontal throw.Water seal assembly shall consist of a Teflon- t; ' coated Belleville spring washer. Installation shall permit sprin- 4 kler deflectors to be positioned 4" (102mm) to 12" (305mm) Ste2 below the ceiling. Sprinklers shall have a nominal K-factor p of 5.6 (80), and 1" NPT thread. Sprinkler temperature rating .. shall be [155°F(68° C)] and [200°F(93°C)]. Rated working ....._ ' " pressure shall be 250 psi (17.2 bar). Standard finish: [whit e][chrome][bronze][Special finish-specify]. Quick response I extended coverage horizontal sidewall dry sprinklers shall be Reliable Model DH56,SIN RA1664(Bulletin 016). Step 3 - For recessed EC horizontal sidewall sprinklers: Replace Fes: "horizontal sidewall"with"recessed horizontal sidewall." Add: . - -' ' (1) Recessed escutcheon assembly shall be a two-piece es- cutcheon of push-on and thread off design with '" (13mm) 4 adjustment.Standard finish shall be chrome,white and brass. Quick response recessed horizontal sidewall sprinklers shall Fig.2-XL02 Wrench be Reliable Model DH56,SIN RA1664(Bulletin 016). For concealed EC horizontal sidewall sprinklers: Replace "horizontal sidewall" with "concealed horizontal sidewall." Add: Cover plate assembly shall consist of a brass cover 441 li plate and copper alloy retainer flange. Method of attaching • the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a 1/2" (13mm) cover plate adjust- * ment. Cover plate temperature rating shall be 135°F(57°C) for 155°F (68°C) dry sprinkler and 165°F (74°C) for 200°F (93°C)dry sprinkler. A bulb protector shall be provided and factory installed inside the sprinkler cup to protect the glass * bulb from damage, which could occur during construction before the cover plate is installed.Standard cover plate finish: Fig.3-G3 Wrench [white] [Custom Color- specify]. Quick response extended coverage concealed horizontal sidewall dry sprinklers shall be Reliable Model DH56, SIN RA1664(Bulletin 016). 4. DH56 HSW DRY SPRINKLER 1 1/2" [38.10mm] - 11 Total Adjustment ___________—__ - I-17 IP Ceiling O [__J L-J 1 1/4" [31.75mm] — — 4" [101.60mm] Min. Escutcheon Adjustment �4" [6.35mm] 12" [304.80mm] Max. System Tee Escutcheon Adjustment 1" NPT T 11,-_fp T q\ 1 15/16" h � �� [53.18mm] I IIIIII __ 1" �J 3" Dia. fin— fI - -- I1i �" [76.20mm] 2 1/8" Dia. I II [53.98mm] Hole in Wall 1/4" [6.35mm] Protrusion Sprinkler Can — "A" Dimension Adjustment Nominal Position Range + 1/4" [+6-35mm] of Escutcheon 076FCCA - 1 1/4 [-31.75mm] Available "A" Dim. is 2" to 48" (51 mm to 1219mm) in 1/4" (6mm) increments Note: The Sprinkler Can protrudes 1/4"when escutcheon is in nominal position. Escutcheon adjustment provides + 1/4" (+6mm) to -114" (-32mm) "A" dimension adjustment range. Fig. 4 DH56 HSW RECESSED DRY SPRINKLER i- - - Ceiling _ 1 1/4" Escutcheon h [31.75mm] ' 4" [101.6mm]Min. Cup o 12" [304.8mm]Max.* System Tee 1" NPT %'I' ,+=\ \ I _ — 1 111.W 3 7/32" •Dia. 'i u' n I ... WW1" [81.8mm] 1.111 2 5/8" Dia. ' [66.68mm] Nominal Position Hole In Wall I of Escutcheon 2 9/32" Dia. L-01 [57.94mm] 1/4" [6.35] NCcutcheon Adjustment "A" Dimension �2" [12.7mm] _ Adjustment Range Escutcheon Adjustment 07 60 028 ±1/4" [±6.35mm] 1/4" [6.3N Escutcheon Adjustment Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Note: Do not install the Model DH56 Dry EC Horizontal Recessed Sidewall Sprinkler in walls which have positive pressure in their side space. Fig. 5 5. • • DH56 -SW CONCEALED DRY SPR NKLER PUS oN c,Do THEN �SYsfem Tee TURN TO ADJUST UNTIL TIGHT AGAINST WALL. "NPT (101.6 TO 304 Si 1111111111111111 (57 II�NN� lolef Protrusion Elevated 2 9/32" ��i��� ��� �� 9a] Above Inside Pipe Ow 2= WALL HOLE _ + 2 5/8"[66.68] DIAMETER 3 1 9/16" [39.69] 3/16"[s]6mm] " - "A""Dimenson Coverplate Adjustment Adjusmenf Ran_oe (s12.Jmm—OmmJ Namihol Position of Coverplate�y 3/16"(5.]6mmJ 016.01A DIMENSIONS IN BRACKETS ARE IN MILLIIJETERS 0.0 Coverplate Ad/us(menf~ 1/2"[12.7] ADJUSTMENT Available "A" Dim. is 3-1/2" to 48" (89mm to 1219mm) in 1/4" (6mm) increments Fig. 6 13' ]4m] Minimum Spacing 28' ]8.5m] Maximum Spacing I \\ MODEL DH56 DRY S R NKLER WALL ////�%�j�� 4" 1100mm] min.From Ceiling 2" ]305mm] max From Ceiling 28' ]8.5m] \///;/],� 10' ]3m] 016FC042 Fig. 7 6. *CALL ON* DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL DAMAGE THE SPRINKLER AND/OR THE FITTING. CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY SPRINKLERS. NO INTERNAL INTERNAL OBSTRUCTION OBSTRUCTION I, i FEMALE F K 1 FEMALE PIPS U PIPE 0 10 THREAD THREAD INCORRECT CORRECT CPVC ADAPTER CPVC ADAPTER FITTING OR TEE FITTING OR TEE RELIABLE MANUFACTURES A FULL-LINE OF MODEL F3-PL, MODEL F3QR-PL, AND MODEL DH56 HSW-PL DRY SPRINKLERS THAT HAVE A SHORTER INLET FOR THESE APPLICATIONS. SHORTER Mill LONGER INLET INLET Nimm 11 mimmnamm-- MALE immi MALE 21 PIPE PIPE THREAD / THREAD I MODEL F3-PL, STANDARD MODEL F3QR-PL OR MODEL F3, MODEL DH56 HSW-PL MODEL F3QR OR DRY SPRINKLER MODEL DH56 HSW DRY SPRINKLER BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR APPLICATION 07 6fg08 Fig.8 7. Ordering Information Installation Wrench Specify: Model XLO2 Sprinkler Wrench (Recessed & Concealed) 1. Sprinkler Type (select one): Model G3 Sprinkler Wrench (a)Model DH56 Dry EC HSW Note: A leak tight 1" NPT sprinkler joint can be obtained (b)Model DH56 Dry Recessed EC HSW/FP with a torque of 20-30 ft-lbs (27.1 - 40.7 N-m). Do not (c)Model DH56 Dry Concealed EC HSW tighten sprinklers over maximum recommended torque. 2. Sprinkler Temperature Rating. It may cause leakage or impairment of the sprinklers. 3. Sprinkler Finish. 4. Cover Plate/Escutcheon Finish. Escutcheon Data: 5. Length: "A" Dimension(face of tee to face of ceiling or FP cup/escutcheon assembly-'/z"(13mm) adjustment wall) in 1/4" (6mm) increments. Finishes (1) Note: Standard Finishes(1) 1. The "A" dimension is based on a nominally gauged Sprinkler Escutcheon Cover Plate pipe thread "make-up" of 0.600" (15mm) per ANSI White Polyester(2) B2.1 [71/2 threads approximately]. /Chrome/Bronze White/Chrome White 2. All platings and paintings are decorative and intend- (I) Other colors and finishes are available. Consult factory for details. ed for interior use. (2)cULus Listed as Corrosion Resistant Sprinkler in standard Black or White. UL Listing Category Note:Paint or any other coatings applied over the factory finish will void Sprinklers, Automatic and Open. Quick Response Sprinklers. all approvals and warranties. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries. Manufactured b The Reliable Automatic Sprinkler Co.,Inc. � Recycled ® (800)431 1588 Sales Offices YiisPaper eIiabI (800)844381i-6150588 48 6051 Sales Fax (914)829 2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A 05/10 P/N 9999970308 FlameGuard® SPEARS CPVC FIRE SPRINKLER PRODUCTS FG-2.0312 Complete System of Pipe, Fittings & Solvent Cement ,i Corrosion Resistant • Superior Flow • Ease of Installation s=' Spears® FlameGuard® CPVC Fire Sprinkler Products provide a cost effective alternative to metal systems with advantages of high corrosion resistance, improved system hydraulics, ease of installation and quick °. h, f �%i�', �,) assembly with readily available tools. CPVC Fire Sprinkler Systems are �. : i based on proven mPvgnnmum=PoaucTS products that 0 have been in continuous service for • over 40 years. Spears®FlameGuard® [ `[F(F� products are approved by UL®, FM® -:3 Global, LPCB and Certified by NSF W 4110 ii 41" li International for potable water use. l Check local codes for restrictions and limitations. Corrosion Resistant CPVC Material Does Not Easy Installation for Lower Costs Sustain Biological Growth FlameGuard®CPVC system installations significantly Unlike metal systems, FlameGuard®CPVC products never reduce costs over conventional metal piping by virtually rust,scale or pit and do not sustain biological growth-a cause eliminating prefabrication. Systems can be fully installed of Microbiologically Influenced Corrosion(MIC)which can on site using solvent cement joining methods. destroy metal fire sprinkler systems from the inside out. UL® Listed for U.S. and Canada in Superior Flow Characteristics for Lower NFPA 13, 1FlameGuard® & 13D Systems Friction Losses FlameGuard CPVC Fire Sprinkler Products are UL® The smooth-wall interior surfaces of FlameGuard® CPVC listed for U.S. and Canada applications for Light Hazard systems result in reduced friction loss over metal systems. occupancies as defined in NFPA 13,Residential occupancies The design flow characteristics remain constant throughout up to and including 4-stories as defined in NFPA 13R, the life of the product because there is no interior corrosion and Residential occupancies for one and two family dwellings and manufactured homes as defined in NFPA in the system due to microbiological activity, 13D. Consult Spears®FlameGuard®CPVC Fire Sprinkler Pressure Rated to 175 psi (1200kpa) @ 150°F Products Installation Instructions and NFPA Standards for (65°C) additional applications including air plenum,system risers, FlameGuard®CPVC Products are produced in combinations concealed, exposed, underground, combustable attic, of Schedule 40 and Schedule 80 Fitting configurations con- garage,basement and low pressure dry piping installations. forming to ASTM F 438 or F 439 standards and FlameGuard® Full Limited Lifetime Warranty SDR 13.5 CPVC Fire Sprinkler Pipe conforming to ASTM F FlameGuard® CPVC Fire Sprinkler Products carry a 442 standards. UL® Rated working pressure is 175 psi limited lifetime warranty against defects in material or (1200kpa)@ 150°F(65°C)(LPCB rated to 120°F)(49°C). workmanship.Consult Spears®warranty for additional details. PROGRESSI yE PR GD UCTS FR OM \°N BERT p„,, (-n SPEARS®INNOVATION& KAS dm LPCB o ��( TECHNOLOGY OSYSTEMSM '~ Visit our web site: www.spearsmfg.com 007 • Spears® FlameGuard® . . . The Leader in Innovative CPVC Fire Sprinkler System Products Pioneer in Molded-in Metal Insert Head Adapters Spears® pioneered the development of the FlameGuard® molded-in-place metal thread insert for connection of sprinkler heads to CPVC fire sprinkler systems, plus Metal FIPT threaded female adapters for metal-to-plastic 6.4 b transitions. Developed the Special Reinforced (SR) Head Adapters Spears® FlameGuard® continuous improvement program developed the1114 technology to produce a superior patented plastic threaded fitting - the Special Reinforced(SR)Design.This unique design incorporates a patented thermoplastic compression process that equalizes stresses generated by tapered thread joint make-up. All CPVC plastic body and threads provide a more uniform construction and improved corrosion resistance. Now, the Revolutionary TorqueSafeTM Gasket Sealed Head Adapter • Requires NO Thread Sealants • Eliminates Stress • Prevents Over Tightening • Provides Easy Frame Alignment Spears® revolutionary design features a special molded-in-place Brass Thread Insert fitted with an elastomer gasket seal at the base of the threads. The gasket seal allows a modified thread design that eliminates radial stress and associated problems typical with tapered thread joint make up.The insert is designed to rotate for easy sprinkler frame alignment without over tightening. Patent Pending. Full Assortment of Specialty Products & Fitting Configurations Spears® FlameGuard® provides the specialty fittings needed in today's fire sprinkler systems. Like the adjustable drop nipple for fine-tuning to finished ceiling height,and ringed head adapter for ease of locating during installation. Plus, Spears®FlameGuard®line offers a full assortment of CPVC fire sprinkler fitting configurations including Tees, Elbows, Flanges, Couplings, Caps, Male Adapters, Grooved Coupling Adapters and Unions, sizes 3/4" through 3"; with new 3/4" and 1" Repair Couplings. Complete Size Range of CPVC Pipe 1111111111 Spears®FlameGuard® CPVC Fire Sprinkler Pipe is available in sizes 3/4" to 3". Conforms to ASTM F 442 standard for SDR 13.5 CPVC pipe. Spears° Solvent Cements & Thread Sealant FlameGuard®products should be installed using Spears® FS-5 One-Step Solvent Cement. For threaded joints, use Spears® BLUE 75'" Thread Sealant that has been tested for compatibility with FlameGuard® CPVC Fire Sprinkler Products. Spears® TorqueSafeTM Gasket Sealed Adapter requires no sealant. Consult sprinkler head manufacturer prior to use. Installation Training Available - Contact Spears® Technical Services for Details FlameGuard®Products must be installed in accordance with Spears'CPVC Fire Sprinkler Piping Products Installation Instructions,National Fire Protection Association Standards 13, 13R, 13D,and in accordance with local codes.Code requirements andfield conditions may differ. It is the responsibility of the installing contractor to insure that the product is suitable to meet these requirements. SPEARS® MANUFACTURING COMPANY �• CORPORATE OFFICE SPEARS 15853 Olden St., Sylmar, CA 91342• PO Box 9203, Sylmar, CA 91392 (818)364-1611 www.spearsmfg.com ©Copyright 2012 Spears®Manufacturing Company. All Rights Reserved.Printed in the United States of America 03/12. FG-2-0312 f 'l 1. Klbll Pripet BOO 825.1286•www.piorwarplps.cotn q/ r Scope Bending Test CDold3 ' Covers black and hot-dipped galvanized furnace butt-welded For NPS 2°and under (continuous welded)Grade A pipe. Pipe is intended Degree of Bend Diameter of Mandrel . for mechanical and pressure applications and is acceptable Standard 90' . 12 x outside pipe , for ordinary uses In steam,water,gas and air lines. Pipe diameter Close Coiling 90' 8 x outside pipe Is suitable for welding,threading,grooving and bending. diameter Flattening Test Hot-Dipped Galvanized , As a test for quality of the weld for pipe 2W NPS and larger, The average weight of zing coating shall be not less than position the weld at 90'from the direction of force and flatten until the 1.8 oz.per sq.ft.of surface(inside and outside). OD is 3 of the original outside diameter. No cracks shall occur along • • When galvanized pipe is bent or otherwise fabricated the inside or outside surface of the weld. • to a degree which causes zinc coating to stretch or compress beyond the limit of elasticity,some flaking'of the coating Frequency of Tests may occur. Tensile tests are required on each lot of 25 tons or fraction thereof I of pipe NPS 1W and smaller and from each lot of 50 tons or fraction Hydrostatic Testing thereof of pipe NPS 2 and larger. • Hydrostatic lest pressures for plain-end pipe are For NPS 2W and larger,a flattening test is also required on each lot of Indicated below. 50 tons. NPS Std.Weight Extra Strong W through 1" 700 psi 850 psi Dimensions and Weights 1W through 3" 1000 psi 1300 psi The dimensions and weights furnished under this specification are in • agreement with the standardized dimensions and weights specified in End Finish ASME B 38.10. • Plain End: Black Plain End NPS 1W and small=unless otherwise specified on order, Permiselpale . end finish shall be at the option of the manufacturer. Variations Sch.40 Soh.80 In Wall Nominal OD Weight Weight NPS 2"and larger,STD and XS weights:ends beveled Size inches Wail Lb./FL Wall LbsJFt. • to angle of 30',+50,-0'with a root face of ,'y *%". Thickness 1/4' .405 .068 .24 .095 .31 Minimum wall thick- '/+' .540 .088 .43 .119 .54 • • Threaded:To ANSI Standard B 1.20.1 ness at anyv'• .675 .01 .87 .148 .04 point shall y"" .840 .109 .86 .147 1.09 not be more than % 1.060 .113 1.13 .154 1.48 • Couplings:To ASTM Standard A 885 1' 1.315 .133 1.68 .179 2.17 12.5%under nominal 1'/4' 1.660 .140 2.27 .191 3.00 1Ih' 1.000 .146 2.72 .200 3.83 . Chemical Requirements wall thickness 2" 2.378 .164 3.88 .218 5.03 2'/"" 2.875 .203 5.80 .278 7.87 Composition,max.% specified. 3" 3.600 .218 7.58 .300 10.26 Carl Manganese Phosphorus ' j lfur ' 30 1.20 .05 .048 Permissible Variations In Outside Diameter NPS 1'/:"and under: 3:.016" I *Copper *Nickel *Chromium *Molybdenum *Vanadiumi .40 .40 .40 .15 .08 NPS 2"and over, *1% *The combination of these five elements shall not exceed 1.00%. Permissible Variations Weight Per Foot Pipe shall not vary more than*10%from the standard specified. Tensile Requirements Tensile Strength,min. 48,000 psi Product Marking Each length of pipe 1/4"NPS and larger is continuously stenciled to Yield Strength,min. 30,000 psi show the manufacturer,the grade of pipe(ASTM A53),the kind of pipe • Elongation in 2° Refer to A53 Table X4.1 (F for continuous weld,A far Grade A),the size,XS for extra strong, and length. Legal Notice: This brochure is intended for general information only. Pioneer makes no warranty or representation,expressed or implied,of any kind with respect to the information contained herein and shall in no event assume liability or responsibility for any loss,damage or injury whatsoever resulting from the use of this Information. In all cases,the customer is therefore requested to use this information at its own risk and responsktiity. Neap_-=-- North American Pipe&Steel www.napsteel.com NAPSteel FIRE SPRINKLER PIPE North American Pipe & Steel has been a trusted source for steel piping products since 1981. With strong ties to mills in the U.S. and abroad, we are certain to supply "What you need when you need it". Our fire sprinkler line of pipe is another example of our commitment to meeting the needs of our increasing customer base. NAP SuperFlow and NAP Schedule 10 Pipe is: manufactured to ASTM A135, A795 and A53A. UL listed and FM approved for fire sprinkler applications including roll grooved, plain end and welded joints. fully traceable. NAP SuperFlow c c®. t6 . 6 N y trk p L' N 1 � _ '"' '0a" r:- ) ,, '°"'� 1' _lt',, & 1g)f 'Ott t ',' " 9 'tk' f ' ' x"� r i E. 4 x r et f � 1. ,v "'� � z C� � - � r�k � 11'Pr* S. sps.,rd&..x.. _.. .. .? Z:' '!,..:F, :,1 1. .Zs,�'c.,+ .>r, st4.1', 'iYre% .i.Fr, 1-1/4" 1.660 1.494 1.400 61 300 3.70/0.26 P r $40,` y ris 1 10 . o�� 4%,dm' k1.040 min :‘:,7:::::1:1 A'�,k 1. ,..:..- EIIIIIIIIIEEIallIll 2.1852.320 2 320 ® 300 3.58/0.30 3" 3.500 3.320 3.280 19 300 1.27/0.09 0 8 g t.x 0 � �� � * i =, '�� ... -9 is �: ����� 0- , C J , .' NAP Schedule 10 L','0-1.' .'»sv X C''�?7' '� ,...- 1 xr1,,' a^' ` S'e Z F ��.5' k>r �F!'� }14 ` �'�+' C.. y� ��� ' Za"1,,, � }6�P-i � :4 #„ P.d � c.''''''� Y C�p_ � �`;(� y�, .' , , q,,, , r), -, x,' , ay E,'T*, 'a'.Zi'.,, Egg,i !'"ii''` . . �1'Y'. :sT'v q ,,,---s,,,,,,'. F �' 1-1/4" 1.660 1.442 1.400 61 300 1111111111111 1:,-1!' . I 0., '1.64 4 4.8.,-0, $1-0-, '4, .4 ,x40-; `--0O,, s., 2" 2.375 2.157 2.320 37 300 — 2-' 21'5 3' ) <'2 3$– -248b.;=,, 30°`- 300 "4 3" 3.500 3.260 3.280 19 300 IIIIIIIIIIII '4',',..„. ,;R, 4.500 :4'. a �4�5/V'h 19 1.* .�15 O.x'v ` raj . NAP Super Flow Pipe and NAP Schedule 10 Pipe are manufactured by MS Pipe Co., LTD, South Korea Surrey, BC Longview,WA Auburn,WA Nampa, ID 11933 Tannery Road,V3V 3X1 7 International Way, 98632 3136 B Street NW,98001 2114 Delta Drive,83687 1-800-665-7473 1-877-735-0275 1-877-735-0275 1-877-735-0275 Iron Threaded Fittings Ductile /. //el { R ( HIN1 r4 Ductile Iron Threaded Fittings . •r � a'� • branded fittings are UL Listed and FM Approved at 500 psi • Rated to 300 psi WSP c ®L us • Ductile iron castings conform to ASTM A536 LISTED • Fitting dimensions conform to ASME B16.3 • Bushings and plugs conform to ASME B16.14 41:;1° • All fittings are 100% air tested APPROVED • NPT threads on all fittings conform to ASME B1.20.1 • Independent lab verification that fittings meet applicable chemical&mechanical properties • Manufacturing facilities are ISO 9001:2008 and ISO 14001 • ProPakTM Packaging per re �ork�ng P ss re,Noe hock j,s ' .•Degrees F ciaS D mti*ad® join °n -20 to 100 500 200 480 300 440 1-471 woo 400 400 Yrr 500wog360 • Airft, 111 tl 600 by 320 ,t »3:y. �J � ~yx�}K�1� i i^t��'. s� ���� � Y.:�4���.f:...-` • .. v _ SCI ProPakTM System `�: ' ! Ductile Iron Threaded Fittings - Class 300 UL/FM c03uS 11> APPROVED Fig. 35E 3 90°Elbow LISTED A r 1 t r° z'; .r A 1 t - "` ` "T1a h : pt,,.......„, ..3.1 _ . s a [, ,,Jc,.s, t t � •1.a':.- ___+Q 35E 3004 1.13 100 200 0.2 /moi 1 1 A 1 35E 3010 1.50 i 40 80 0.5 1-1/2 35E 3014 1.94 18 36 1.1 D - .,,_,,,y' :.--.0ua. :1 1,-.P:s: :?" i Pfs'''' _. .65"''w' 4y t7 4•..4'' iW. NF 2-1/2 35E 3024 2.70 4 8 3.2 C T Fig. 35RE3-90°Reducing Elbow E B artl�I�mbr h, B Wel ht: I� ��'•.•� 35RE3006004 1.20 1.22 80 160 0.3 • •• ',` 44 (-5,: n;-,,,,,,,,,,,4:4:!,,,,R #1 z 9 A'' f``. -, <t ., ' ',., " A rc ••• 1 x 3/4 35RE3010006 1.38 1.45 50 100 0.4 A tipe 1-1/4 x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/2 x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 :.�..:. '&1a c.A%.,4,1.*..04.,1`z:- .. Ia.., «i�: .., 14..r..ri# .,..,,,, .+�.n AM 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 +, ri ,�i: : .. 4t ".!t.�... ..r.. jj0 ,"Z w -^ :4 if` .,tAt< :, 41:.:',;':',2 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 y 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Fig. 35F 3-45°Elbow °' � 1fackIWgh� �, 1/2 35F 3004 0.88 150 300 0.2 • so. x..1 1 H7Gv'S eT' -_ 'i�4 'S"" 0.�°s' .. t .,' s �^gp'' .✓. �a Y .+?y .�3' .5`2 3 ` -' C yam° 4 F 4 "P 'ta.j: �. �; ��� 1 35F 3010 1.13 40 80 0.5 44.m �► ,� �A 1-1/2 35F 3014 1.44 20 40 1.0 I 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size.p -c, Farts 1 er g l'ickiniDx k lila( :- :r �` .r, : river Master;. -rb "- iIA 1/2 35T 3004 1.6113 80 160 0.3 1 r 35T 3010 1.50 gs�5 25 50 yggi 0.7 ,1 ILE_m..sx](---)If--) 1-1/2 35T 3014 1.94 10 20 1.5 A A t g '4..` .'' ? "_ . F.` . X 11 1' k 2-1/2 35T 3024 2.70 4 8 4.3 201 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com (,_ i Ductile Iron Threaded Fittings - Class 300 UL/FM c00us ® Fig. 35RT3-Reducing Tee LISTED APPROVED !WI ` .1 l '-'t '� -- •' ��Vs-: �re .'i`�{� .9 ..'j( -.�C� -`]- I til t rA7 r :. ... _ : I asterb" I %"�� C 3/4 x11/2 _ 35RT3006004 1.20 1.20 1.22 60 120 0.4 I� -Jr 1 x 1/2 x 1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 D (-Er) B illb E A ix 3/4 x 3/4 135RT3010006006 1.38 1.31 1.45 35 70 0.6 1-1/4 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 A4 *X/04444A a p ir, ..,A'f, .a:: Vt Cit-..: a p y* � ,..wrz 11.1/4 x 3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 „ i 3C P tis .{k 4 R C i'T' 1 , 3r C rm^fiM 1-1/4x 1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4 x 1 x 3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x1 x 1-1/4 35RT30122010012 1.75 1.69 1.75 15 30 1.0 4t 1-1/2 x 1/2 x 1-1/4 35RT3014004012 1.81 1.56111.88 24 48 1.1 r1[ dM, °n� ¢Et Ik';..:�:.tT,ai z '�.NC.spa: AW ",:i t.�.:+�S_: 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2 x 3/4 x 1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 0r ;!,::::,*444.0*:, r c 1-1/2 x 1 x 1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1 1/2 x 1 x 1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1W2, I`'F moo 1: ,::z:l _,.r. 1' 1-1/2x 1 x 1-1/2 35 RT30140100i14 iv 1.94 1.80 j�1.94 12 24 1.3 as 1-1/2 x 1-1/4 x 1/2 35RT3014012004 1.41 1.34 1.66 16 32 0.9 1 1/2 x 1-1/4 x 1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2 x 1-1/4 x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2 x 3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2 x 1-1/4 x 2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 y 2 x 1-1/2 x 1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 g 0 1.73 1.65 2.02 8 16 1.5 ;a 1-1/2: ..' % *RT3 4 ', 4 2 1; ,` t,,Kt" 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3-Bull Head Tee size Ft '4.:- A. '',[1.1'.."-: Gl ,� 'i :raf Number :bac`intj` Ne ght, Q NE C -. in in „ iii" n .trine- Mastek ;.1 iii 111111 ��" 3/4x 135BT3006010 1.45 1.45 1.37 30 60 0.6 ,i,. 7�i)/14 ;- .* 831'!413 ' °. , ' ; ,. , } 35.-, 0 ,0 1 80 1,65 15 30 15 1.0?° 14x1 , E-�I; 1-1/4 x 1-1/2 35BT3012014 1.88 1-1/2 35BT3010014 1 8 8 1.88 1.82 15 30 1.3 14 ,2 y F ::: �' '',...:W:,a_ .f 't9CIr, .'F .,,-. 1-1/2 x 1-1/4 x 2 35B'5 ` ,T3014012020 2.16 2.10 2.02 10 201.8 .:.1"-,14;7g,77 ._ "`ft$0`144'2f�_. 2:167 2 Z 16 413 • .. $ ` it _ . . # 202 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com • r Ductile Iron Threaded Fittings - Class 300 UL/FM cIZOus APPROVED Fig. 35CP3 —Straight Coupling with Ribs LISTED A 1 -- -- -- 'mmili 7:!;)::.Ittli :C...;::7.1::''''''4Zit:::;;'.;,*;:'.1;;P:4":14mi.'':;;,:i;:,:47'tiiif;4:r:Iiie'IT4111'47. - 1/2 35CP3004-''''''''''''''''''''''fil 138 200 400 0.1 t oma' F .__� ���_ 1 35CP3010 1.75 60 120 0.4 d ate' 1-1/2' 35CP3014 2.19 25 50 0.7 'ti;';.1isiTheittS.eli i.;:$1$114:'i.W.i. ...11:4.4eA.:; 11);-::-'..i'.'::iil:kah:Z I;r:74.,itgrgt iir U' 2-1/2 35CP3024 3.00 9 18 I Fig. 35RC3 —Hex Reducing Coupling u : 4-13ill. i'-' ti Wei r . ..r«. 1 '► ' " tc ..-., _. A1 x 1/235RC3010004 1.69 80 160 0.3 11111 1 1/4 x 3/4 35RC3012006 2.06 40 80 0.6 Fig. 35HB3 —Hex Bushing B 35HB3010004 1.06 1.40 180 360 0.2 1111. 1 1 IA 1-1/4 x 1 35HB3012010 1;19, 1:80 90 180 0.2 ,` 1-1/2 x 1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1-1/4 35HB3020012 1.38 2.55 40 80 0.6 _ i°, <araa ^ , ,C ,' ,.., y a IT Fig. 35SP3 Square Head Plug ',.,.:W.;;;''i''?,:'..:!:!,1!#.1:'.ij''':;11:!'-'j Zit;.':;:c;!".iiiii ii.;71111g;<::::4-.:I;: ''''''k,.,:m!,,t,, III �w"�. 1/2 35SP3004iiiP. 0.94 600 1200 0 07 %`` R/ i A 1 35SP3010 1 25 200 400 01 .v 0 o ;.,..'7,; Via. aa: * :. 54'e „,. 1-1/2 35SP3014 01MM 80 160 0.4 :acs 41 iei„ ,. aA4l Fig. 35U 3— Union with Brass Seat A r • 1 35U 3010 2.19 20 40 1.0 k.,..s. -__- V`.. • ` ',. a: y'. i.,,5 4,,. ssu • 'n ,,.x ', '+',4, ..,aa - '" 1-1/2 35U 3014 2.62 10 20 1.7 203 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com I Ductile Iron Threaded Fittings - Class 300 UL/FM C (;) us APPROVED A A Fig. 3513 CrossLISTED E��F--� ize 1,1 � cit fi a � si -/� . .. ,a . .0 b =. I Tijiwt \. --� ,. A 1 35X 3010 1.50 20 40 0.9 4. II ,--- Cl I1-1/2 35X 3014 .;,,-1,,.,9..4 8 .be D L!�■ U T„ I B B Fig. 35RX3—Reducing Cross A 1 the Mei#e — I _ _, 1-1/4 x 1 35RX3012010 1.67 1.88 15 30 1 2 _1_ s � E � " A f � a ,s ••-••-‘Ni IA 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3—Cap , _,,, ,,,,, , 1 , ,,;,,, ,., 4, 1,74 1, t� fin " �'::::'::::::':::':'1::--4"118.::: (.#1 •�ma.NikNi\� A 1/2 35C 3004 0.87 300 600 0 1 7 ,l 1 35C 3010 :::,.:.:4..,:;r;;:::z,r.7,.. 110 220• 0 2 1 1/2 35C 3014 1.33 50 100 0.5 2-1/2 356. 3024 1.70 18 36• 1.6 .,. ...,. Fig. 35BC3—Beam Clamp '.,••••••• ... '.: .I- —.-.. Pli.m.1 ,-!,", 1n, rt , � . t .r�. ' en ,,,fi ......1e-5 �rx a , : _. Ai ► ./ 3/8 356C3003 0.7610600 0.3 rr sw if„::.:..:..,.,... 204 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com FireLock® Fittings .✓�taulic 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. III Fitting Coating: ElOrange enamel o Red enamel in Europe, Middle East, Africa, and India ❑ Optional: Hot dipped galvanized Approvals/Listings: cCI us ® LPCB vas VP LISTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic victaulic.com I FireLock® Fittings I Publication 10.03 • Dimensions: H-CtoE. C 0 CtoE 4 i top .1.4.... T -le �o I, 11 to E `� � i oo =�=� tE I NO.001 NO.003 NO.002 No.006 No.001 No.003 No.002 No.006 90°Elbow 45°Elbow Straight Tee Cap Actual Approx. Approx. Approx. Approx. Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. mm mm mm kg mm kg mm kg mm kg 1'/4 1.660 32 42.4 - - - - - - 0.82 0.3 1�/z 1.900 - - - - 21 0.1 40 48.3 - - - - 21 0.4 - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 2' 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108 mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 139.7 mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - - 159 mm 6.250 5.50 12.6 3.50 9.2 550 17.9 158.8 140 5.7 89 4.2 140 8.0 - _ - . 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 - - 8 8.625 6.81 25.5 4.25 20.46.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 • 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaulic® victaulic.com I FireLock® Fittings I Publication 10.03 • Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' Nominal Outside No.002 Size Diameter Elbows Straight Tee inches inches No.001 No.003 mm mm 90°Elbow 45°Elbow Branch Run 11/4 1.660 - - - - 32 42.4 - - - - 11h 1.900 - - - - 40 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm ( 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 I 5.0 13.0 200 219.1 4.0 1.5 10.01 4.0 ' The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the "QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. • • 10.03 1539 Rev M Updated 12/2014 ©2014 Victaulic Company.All rights reserved. �Cts'�U�iC victaulic.com 3 Victaulic® FirelockTM Rigid Coupling ✓ctaulic® Style 009N 10.64 Patented 1.0 CERTIFICATION/LISTINGS LPCB Vds C104-1a/36 2.0 PRODUCT DESCRIPTION • The FireLock EZTM Style 009N Installation-ReadyTM Rigid Coupling is for use in the fire protection market. • The coupling's unique design eliminates loose parts, promotes consistent installation and provides substantial gains in productivity. • IMPORTANT: FireLock EZTM Style 009N couplings are recommended for use ONLY on fire protection systems. 3.0 MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) ❑ Orange enamel (North America, Asia Pacific) O Red enamel (Europe) O Hot dipped galvanized Gasket: (specify choice') ❑ Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. 1 ✓ctaul,c° victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • • 4.0 LISTINGS/APPROVAL 2 The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Nominal Size cULus FM Vds LPCB Sch.5 Sch. 10 Sch.40 Sch.5 Sch. 10 Sch.40 inches psi psi psi psi psi psi psi psi mm kPa kPa kPa kPa kPa kPa kPa kPa 1 Y4 232 365 365 175 363 363 363 363 32 1600 2517 2517 1205 2502 2502 2500 2500 11/2 232 365 365 175 363 363 363 363 40 1600 2517 2517 1205 2502 2502 2500 2500 2 363 365 365 175 363 363 363 363 50 2502 2517 2517 1205 2502 2502 2500 2500 2'/1 N/A 365 365 175 363 363 363 363 65 2517 2517 1205 2502 2502 2500 2500 s 3634 363 363 76.1 mm N/A 251 7 3 N/A N/A 2502 a N/A 2500 2500 3 N/A 365 365 175 363 363 363 363 80 2517 2517 1205 2502 2502 2500 2500 4 N/A 365 365 175 363 363 363 363 100 2517 2517 1205 2502 2502 2500 2500 175 363 363 N/A N/A 108.0 mm N/A N/A N/A 1205 2502 2502 5 290 365 N/A 363 363 232 N/A 125 N/A 2000 2517 2502 2502 1600 a 133.0 mm N/A N/A N/A N/A 25024 N/A N/A N/A s 3634 232 N/A 139.7 mm N/A 2000 5 N/A N/A 2502 4 N/A 1600 363 a N/A N/A N/A 159.0 mm N/A N/A N/A N/A 2502 4 165.1 mm N/A 290 N/A N/A 250244 N/A N/A N/A 2000 a 6 N/A 290 365 N/A 363 363 232 N/A 150 2000 2517 2502 2502 1600 363 a N/A N/A N/A 216.0 mm N/A N/A N/A N/A 2502 4 8 N/A 290 365 N/A 363 363 232 N/A 200 2000 2517 2502 2502 1600 2 Listed/Approved for wet and dry pipe systems(>—40°F/-40°C)for continuous use in freezing conditions,use of Style 005H Coupling with Silicone Gasket is recommended. Please see the Victaulic Installation Manual I-009N/009H for details concerning when supplemental lubrication is required. 3 cULus listed for DIN 2458 2.6 mm pipe wall. 4 FM approved for BS 1387 Medium 3.6 mm pipe wall. 5 cULus listed for EN 10220 4.0 mm pipe wall. 6 cULus listed for EN 10255 4.5 mm pipe wall. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ctaiul�lc victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • 4.1 LISTINGS/APPROVAL • Speciality Pipe Pipe Size Pressure Rating Pipe Size Pressure Rating Pipe Size Pressure Rating FM cULus FM inchesus inches psi inches psi psi kPa kPa kPa kPa kPa kPa 300 BLT 1'/a-2 ��. EZT 1'/a-2 �� 365 MT 1Y-2 300 365 2517 2068 2517 DF 1'/a-4 ��, FF 1'/a-4 365 �� 365 MLT 1'/a-2 N/A 365 2517 2517 DT 1'/a-2 ��, 2517 FLF 1'/a-4 365 365 ST 1Y-2 N/A 365 2517 2517 175 175 EF 1'/a-4 06 06 FLT 1Y-2 365 STF 1'/a-4 N/A 365 2517 2517 300 EL 1'/a—2 2068 256 7 I FLTL 1'/a—2 N/A 365 TF 2'/a 4 N/A 365 2517 2517 ET40 11/4—2 300 365 2068 2517 GL 11/4—2 300 365 WLS 1'/a 2 300 365 2068 2517 2068 2517 300 EZF 3-4 32 68 2517 MF 15 '/a-4 300 365 WST 1'/a-2 N/A 365 2068 2517 2517 XL 1'/a-2 300 365 2068 2517 NOTES • BLT=BLT steel pipe manufactured by Allied Tube&Conduit Corp. • DF=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • DT=DYNA-FLOW steel pipe manufactured by Allied Tube&Conduit Corp. • EF=EDDY FLOW steel pipe manufactured by Bull Moose Tube Co. • EL=EDDYLITE steel pipe manufactured by Bull Moose Tube Co. • ET40=Eddythread 40 steel pipe manufactured by Bull Moose Tube Co. • EZF=EZ-Flow steel pipe manufactured by Northwest Pipe Co. • EZT=EZ-Thread steel pipe manufactured by Youngstown Tube Co. • FF=Fire-Flo steel pipe manufactured by Youngstown Tube Co. • FLF=Fire-Line Flow steel pipe manufactured by Western International Forest Products Inc. • FLT=Fire-Line Threadable steel pipe manufactured by Western International Forest Products Inc. • FLTL=Fire-Line Threadable Light steel pipe manufactured by Western International Forest Products Inc. • GL=GL steel pipe manufactured by Wheatland Tube Co. • MF=Mega-Flow steel pipe manufactured by Wheatland Tube Co. • MT=Mega-Thread steel pipe manufactured by Wheatland Tube Co. • MLT=MLT steel pipe manufactured by Wheatland Tube Co • ST=STD wall pipe in accordance with ASTM A53. • STF=Steady Flow steel pipe manufactured by AMS Tube Corp. • TF=Tex-Flow steel pipe manufactured by Tex-Tube Co. • WLS=WLS steel pipe manufactured by Wheatland Tube Co. • WST=WST steel pipe manufactured by Wheatland Tube Company. • XL=XL steel pipe manufactured by Allied Tube&Conduit Corp. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulia victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 5.0 DIMENSIONS Style 009N //�/��Y►- �-Z-Y YY I in J \ii.IJ �rl Style 009N Pre-Assembled Style 009N Joint Assembled (Push On Condition) Dimensions Pre-assembledApprox. Actual Maximum Maximum Allow. (Push On Condition) Joint Assembled Weight Nominal Outside Working End Pipe End Bolt/Nut 9 Size Diameter Pressure 7 Load 7 Separations Size X Y X Y Z Each inches inches psi lbs. inches inches inches inches inches inches inches lbs. mm mm kPa N mm No. mm mm mm mm mm mm kg 11/4 1.660 365 790 0.10 3/a x 2 3.13 5.00 2.75 5.00 2.00 1.4 32 42.4 2517 3514 2.54 2 M10 x 2 79 127 70 127 51 0.6 11 1.900 365 1035 0.10 3/a x 2 3.38 5.13 3.00 5.13 2.00 1.5 40 48.3 2517 4604 2.54 2 M10 x 2 86 130 76 130 51 0.7 2 2.375 365 1616 0.123/a x21/2 4.00 5.63 3.50 5.63 2.00 1.9 50 60.3 2517 7193 3.05 2 M10 x 21 102 143 89 143 51 0.9 2 Y2 2.875 365 2370 0.12 3/8 x 21 4.50 6.13 4.00 6.13 2.00 2.1 65 73.0 2517 10542 3.05 2 M10 x 21/2 114 156 102 156 51 1.0 76.1 mm 3.000 365 2580 0.12 2 3/8x 21 4.63 6.00 4.13 6.13 2.00 2.1 76.1 2517 11476 3.05 M10 x 21/2 118 152 105 156 51 1.0 3 3.500 365 3512 0.12 3/8 x 21 5.13 6.75 4.63 6.75 2.00 2.3 80 88.9 2517 15622 3.05 2 M10 x 21/2 130 171 117 171 51 1.0 4 4.500 365 5805 0.172 3/8 x 21 6.00 7.88 5.63 7.50 2.13 2.9 100 114.3 2517 25822 4.32 M10 x 21 152 200 143 191 54 1.3 108.0 mm 4.250 365 5175 0.17 2 3/E x 21/2 5.63 7.38 5.38 7.38 2.13 3.1 108.0 2517 23020 4.32 M10 x 21/2 152 1.87 137 187 54 1.4 5 5.563 365 8870 0.172 1/2 x 3 7.25 9.25 6.75 9.13 2.25 5.0 125 141.3 2000 39456 4.32 M12 x 3 184 235 171 232 57 2.3 133.0 mm 5.250 365 7897 0.17 1/2 x 3 6.63 9.00 6.38 9.00 2.25 4.8 133.0 2517 35106 4.32 2 M12 x 3 168 229 162 229 57 2.2 139.7 mm 5.500 365 8667 0.17 2 1 x 3 6.88 9.25 6.75 9.13 2.25 4.9 139.7 2517 38529 4.32 M12 x 3 175 235 171 232 57 2.2 159.0 mm 6.250 365 11192 0.17 2 1 x 3% 7.88 10.00 7.38 9.88 2.25 5.6 159.0 2517 49753 4.32 M12 x 3% 200 254 187 251 57 2.5 6.500 365 12105 0.17 1/2 x 31/4 8.00 10.25 7.75 10.13 2.25 6.0 165.1 mm 165.1 2517 53813 4.32 2 M12 x 31/4 203 260 197 257 57 2.7 6 6.625 365 12582 0.17 1 x 31/4 8.38 10.38 7.88 10.13 2.25 6.0 150 168.3 2000 44469 4.32 2 M12 x 3% 213 264 200 257 57 2.7 216.0 mm 8.500 365 20712 0.17 2 5/a x 4 10.63 13.25 10.25 10.13 2.63 11.4 216.0 2517 55968 4.32 M16 x 4 270 337 260 257 67 5.2 8 8.625 365 21326 0.172 5/8 x 4 10.88 13.38 10.25 13.13 2.50 11.4 200 219.1 1620 94863 4.32 M16 x 4 276 340 260 333 64 5.2 7 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.See the Listings/Approvals section of this publication for ratings on other pipe. 8 The allowable pipe separation dimension shown is for system layout purposes only.FireLock EZTM couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. 9 Number of bolts required equals number of housing segments. NOTES • When assembling FireLock EZTM couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZTM Style 009N couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009N couplings.IMPORTANT:Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009N coupling.There is no interchanging of gaskets or housings between coupling styles. • Use Of Flushseal Gaskets For Dry Pipe Systems FireLock EZTM couplings are supplied with FireLock EZTM Grade"E"Type A gaskets.These gaskets include an integral pipe stop,that once installed provides the similar benefits as a FlushSeal gasket for dry pipe systems.It should be noted that standard Victaulic Flush-SealTM gaskets are not compatible and cannot be used with the FireLock EZTM couplings. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com4 ✓ctaulic • victaulic.com I Couplings I FireLock I Rigid I Style 009N I Publication 10.64 • • 6.0 RTIALS • PublicationREFE05.01:ENCE Seal SelectMAion ERGuide I-009N/009H:Installation Instructions FireLock EZTM Rigid Coupling • User Responsibility for Product Selection and Suitability • Each user bears final responsibility for making a determination as to the suitabilityof Note This product shall bec manufactrdance with d by Victaulic c or to tallVictaulic ion assembly in t.All products Victaulic products for a particular end-use application,in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications,as well as Victaulic performance,maintenance, Victaulic reserves the right to change product specifications,designs and standard safety,and warning instructions.Nothing in this or any other document,nor any verbal equipment without notice and without incurring obligations. recommendation,advice,or opinion from any Victaulic employee,shall be deemed to alter,vary,supersede,or waive any provision of Victaulic Company's standard conditions Installation of sale,installation guide,or this disclaimer. Reference should always be made to the I-009N/I-009H Firelock EZ Rigid Coupling Intellectual Property Rights Installation Instructions for the product you are installing.Handbooks are included with each complete instalation No statement contained herein concerning a possible or suggested use of any material, and are sh(pment available n'PDF formatt ontoupr roviding website at www.victaulic.comand assembly data, product,service,or design is intended,or should be constructed,to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries Warranty or affiliates covering such use or design,or as a recommendation for the use of such Refer to the Warranty section of the current Price List or contact Victaulic for details. material,product,service,or design in the infringement of any patent or other intellectual Trademarks property right.The terms"Patented"or"Patent Pending"refer to design or utility patents Victaulic,FireLock EZT"",Flush-Seal."',and Installation-Ready.are trademarks or or patent applications for articles and/or methods of use in the United States and/or other registered trademarks of Victaulic Company,and/or its affiliated entities,in the U.S.and/ countries. or other countries. • • 10.64 7072 Rev G Updated 10/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5ictaulIcr CARBON STEEL PIPE—GROOVED COUPLINGS.. V • V • y - r sy OC1 �IC1 to ® VdS 1LISTE �PCB Reducing SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run. Designed to replace two couplings and a reducing fitting,the Style 750 features a special reducing gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. Qtr/!�� MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536,grade 65-45-12. Ductile iron conforming to ASTM A-395,grade 65-45-15, is available upon special request. Housing Coating: Orange enamel • Optional: Hot dipped galvanized and others Gasket: (Specify choice*): • Grade"E"EPDM (All other sizes) EPDM (Green color code).Temperature range—30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°F/+82°C potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade"T"nitrile Nitrile(Orange color code).Temperature range—20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional: Assembly Washer:Galvanized,carbon steel Bolts/Nuts: Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com �CtauliiC VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.08 1 REV J • CARBON STEEL PIPE-GROOVED COUPLINGS VO.V O Reducing Coupling STYLE 750 DIMENSIONS Max.Work Allow.Pipe Bolt/Nut@ Size Pressure Max,End Load` End Sep. Approx. � Deflect.Fr.Cir No-Size Dimensions-Inches/mm Wgt.t.Each Nominal mi al Per Pipe Cpig. In./Ft. psi aNs Inches/mm Deg. Lbs. Inches/mm minim Inches X Y Z kg 2 x 1 350 500 0-0.07 0.20 3.38 50 528 1.88 2.7 25 2410 2225 0-1.8 0 57 17 2-3/8 x 2 85 134 48 12 11/2 350 1000 0-0.070.20 38 5 28 1 0 0°-57' 2-3/8 x 2 , 3. . .88 2.0 40 2410 4450 0-1.8 17 85 134 48 I 1.0 2' x 2 500 2215 0-0.07 0.16 65 50 3450 9850 0-1.8 0 -47 2-3/8 x 2 4.00 5.93 1.88 3.1 14 102 151 48 1A 76.1 mm x 2 350 1550 0-0.07 50 2410 6900 0-1.8 0°-47 0.16 2-Yz x 23A 4.38 6.63 1.88 4.6 14 111 168 48 2.1 3x 2 350 1550 0-0.07 0.13 _.... 80 50 2410 6900 0-1.8 0°-39' 11 2-1/2x23/4 475. 7.13 1.88 4.9 21/2 500 3250 0-0.07 E 121 181 48 2.2 0.13 65 3450 14460 0-1.8 0° 39' 2-1/2x 2 3/ 4 75 7.13 1.88 4.3 11121 181 48 2.0 889mm x 761mm 350 2475 0-0.07 ;G 0,13 4.75 7.13 1.88 42 2410 11010 0 1.8 0 39 11 2-Yzx23/a _..._ �.. _ 121 181 48 1.9 4 2 350 1550 0-0.13 100 x 1 19' 0.28 ' 2-5/8 x 3/4 6 25 8.90 225 8.1 50 2410 6900 • 0-3.2 25 159 226 57 3.7 2%z 350 2275 0-0.130.28 6 25 8.90 225 8.6 65 2410 10125 0-3.2 19 I 25 2-5/8x31/ 159 226 57 3 500 4810 0-0.13 .. . ... ..._ ,...__ 80 3450 21400 0-3.2 0'28 6 00 8.90 225 6.7 1 9 25 2-5/8x3%a 152 226 57 3.0 350_.....__; .2475 i 0-0.13 0.28...... � 114.3 mm x 76.1mm 2410 11014 0-3.2 1°-19 25 2-5/8x3/4 625 8.90 225 6.9 159 226 57 3.1 5 4 350 t 5565 0 0.13 125 x 100 2410 24765 0-3.2 1°-3' 0.22 , 2-3/4x 4/4 7.18 10.70 213 112 19182 I 272 54 5.1 6 4 350 5565 0-0.13 0°-52' 0.18 2-3//x41/ 150 863 11.90 225 6.7" x 100 2410 24765 0 32 15 181 302 57 7.6 5 350 ! _ _.. ..., ,_.. 8500 0 0.13 125 3 2410 37825 0-3.2 0°-52 �58 2-3/ax4r/a 8.31 11.90 225 129 I 211 302 57 5.9 165 1 mm x 4 350 5565 0-0.13 0 55' E 100 2410 24765 0-3.2 0.19 2-3//x41/ 863 11.90 225 152 ___....... 16 219 302 57 6.9 8 6 350 12060 0-0.13 � ,._... __._. ,; _ .. 200 x 150 I 2410 53645 0 3.2 0 38 01113 2-7/8 x 5 10.81 14 88 250 22.4 _ " 275 378 64 102 2191mm x 165.imm ? 350 11610 0-0.13 0.13 1075 14.88 250 23.2 2410 51645 0-3.2 0 -38 11 2-7/8x5 273 378 64 10.5 10 8 350 20450 0-0.13 273 x 219.1 2410 90970 0-3.2 0°-25' 0'9 2-1 x 5 Yz 1312 17.26 2 62 31.4 8 , 333 438 67 142 Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details. *Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for 3/4-31/2720-90 mm;25%for 4'%100 mm and larger. @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. Y > I k-Z i c YY 4-Z4-Z-0.12-���1 Tr-RI f umi \mei Il II 11 4� J` j1, \� .moi • • www.victaulic.com VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ✓ctauluC 06-08 2 REV J CARBON STEEL PIPE-GROOVED COUPLINGS VO.VO Reducing Coupling STYLE 750 FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Pipe Size Length Size Length Nominal Nominal Size Sm.Dia. Size Sm.Dia. Inchestmm Feet/m Inches/mm Feet/m 21 5.9 1 2 2.7 50 x 25 ` 1.8 25 x 50 0 8 1% 1 2.0 11/2 2 1.9 40 I 0.640 x 50 0 6 2% 2 1.9 ._..._ 2 x 2'k 1.0 65 x 50 0.6 50 65 03 __..... .1mm 1.0. 76.1mm 76 x 50 06 03 3 x 2 55 3 35 80 50 1.7 80 11 2% I 3.8 4 3.0 65 12 100 09 88.9 mm x 76.1 mm i 3.8 2I2 x 3 25 1.2 65 80 0 8 42 6.0 4 30 100 x 50 + 18 100 0 9 2Yz t 6.02.5 761 mm x 889mm 65 r 1.8 0.8 3 6.0 114.3mmi 3.0 80 1_ 18 09 6.0 3 4 2.5 114.3 mm x 761 mm 1.8 80 x 100 0.8 5 4 3.0 45 33 125 x 100' 0.9 100 x 125 1.0 6 4 6.0 6 4.6 150 x 100 1.8 150 14 5 4.54.6 165.1 mm 125 ti 1.4 ! 14 165.1mm x 4 6.0 5 6 2.3 100 18 125 x 150 0.7 8 6 7.3 6 x 8 60 200 x 150 ; 2.2 150 200 18 S.4 219.1 mm x 165.1mm1 2 3 165.1mm x 2191' 65 10 8 } 87 8 10 63 273 x 2191 2.65 2191 x 273 19.2 www.victaulic.com �CtaU�iC� VICTAULIC ISA REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. RFV .I CARBON STEEL PIPE—GROOVED COUPLINGS V • . V • Reducing Coupling STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV J UPDATED 08/2012 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. �Gt4iL1lIC2° 06.08 Victaulic® Flexible Coupling ✓CtaUl;d Style 75 06.05 " , • Victaulic RX roll sets must be used when grooving 0I u light-wall/thin-wall stainless steel pipe for use with dip Victaulic Couplings. U I Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or Exaggerated for clarity property damage. Approvals/Listings ® Or LPCB 0 Q VdS NOTICE • Victaulic RX grooving rolls must be ordered See Victaulic publication 10.01 for details separately. They are identified by a silver color and See Victaulic publication 02.06 for portable water approvals if applicable. the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. 1 ictauIiCC victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Bolts/Nuts: Ductile iron conforming to ASTM A-536, grade 65-45-12. Heat-treated plated carbon steel, trackhead meeting the Ductile iron conforming to ASTM A-395, grade 65-45-15, physical and chemical requirements of ASTM A-449 and is available upon special request. physical requirements of ASTM A-183 Housing Coating: (specify choice) ❑ Standard: Orange enamel. ❑ Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE:Additional gasket styles are available.Contact Victaulic for details. ❑ Grade "E" EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to +110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. ❑ Grade "T" Nitrile Nitrile (Orange stripe color code). Temperature range 20°F to +180°F/29°C to +82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓CtauliC victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 • Dimensions Style 75 r Y �z-1 ,:,i��E IF II �� �I„I �i I`lll Actual Maximum MaximumAllow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation3 Centerline3Bolt/Nut4 X Y Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. mm mm kPa N mm Degrees mm/m (No.)size inches mm mm mm kg 1 1.315 500 680 0-0.06 2°�3, 0.57 2-3/S x 2 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 1'/a 1.660500 1080 0-0.060.45 2.68 4.61 1.77 1.4 2°-10' 2-3/8x 2 68 117 45 0.6 32 42.2 3450 4805 0-1.6 38 1'/2 1.900 500 1420 0-0.06 1°-56' 0.402-3/8x 2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 5002215 00.06 1°-31' 0.32 3.43 5.22 1.88 1.7 23/8 x 2 - 50 60.3 3450 9860 0-1.6 26 87 133 48 0.8 2'/z 2.875 500 3245 0-0.061°-15' 0.26 2-3/8x 2 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 22 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 0.26 4.00 5.90 1.88 1.9 1°-12' 2 3/5x2 102 150 48 0.9 76.1 3450 15730 0-1.6 22 3 3.500 500 48000-0.060.22 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 10-2' 18 2-'h x 2 3/a 114 178 48 1.3 3'/z 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0°-54' 16 2-'/z x 2 3/a 127 191 48 1.3 4 4.500 500 7950 0-0.13 0.34 5.80 8.03 2.13 4.1 1°-36' 2-'/z x 2 3/a 147 204 54 1.9 100 114.3 3450 35380 0-3.2 28 108.0 mm 4.250 450 6380 0-0.13 0.35 5.55 7.79 2.13 3.7 1.-4 1' 2-12 x 70 141 198 54 1.7 108.0 3100 28395 0-3.2 29 4'/z 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 1°-26' 2-5/8 x 3'/a 156 240 54 2.5 120 127.0 3100 39250 0-3.2 21 5 5.563 450 10935 0-0.13 0.27 23 5/a 6.88 10.07 2.13 5.8 10_18' 2- x 3 Ya 175 256 54 2.6 125 141.3 3100 48660 0-3.2 133.0 mm 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 1°-21' 2-16 x 82.5 166 238 54 2.7 133.0 3100 43325 0-3.2 24 5.500 450 10665 0-0.13 0.28 6.80 9.59 2.13 6.3 139.7mm 1°-18' 2-5/ax3'/a 173 244 54 2.9 139.7 3100 47460 0-3.2 24 6.000 450 12735 0-0 .21 7.38 10.48 1.88 6.2 152.4 mm 10-12' 2-5/s x 3'/a 187 266 48 2.8 152.4 3100 56670 0-3.2 18 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 1°-5' 2-5/e x 3'/a 203 281 54 3.2 150 168.3 3100 69085 0-3.2 18 159.0 mm 6.250 450 13800 0-0.13 0.24 7.63 10.49 2.13 6.8 10-9' 2-16 x 82.5 194 266 54 3.1 159.0 3100 61405 0-3.2 20 8 8.625 450 26280 0-0.1300-50' 0.18 2_s/a x 4 Ya 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for 3A-3 1/2"/20-90 mm;25%for 4"/100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. ictaulic' victaulic.com 3 victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Note Reference should always be made to the I-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic® •••••••••■•••••••••mmi SA M MV70® SIDEWINDER° FOR WOOD -Horizontal Application Application Product Features Not less than 2"nominal width •No pre-drilling required. (1-1/2")up to 3-1/2"pipe;not less than 3"(2-112")nominal width 4"&5"pipe A •Quick to install using the Sammy 4-4 Floor Joist Nut Driver with an 18V cordless drill/driver. li. ' Minimum 2-1/2"from bottom for branch lines.Minimum 3"from bot- tom for main lines.Exception:This •Saves time from traditional requirement shall not apply to 2"or methods. thicker nailing strips resting on top of steel beams. •Reduces installation costs. - - •Made in the U.S.A. Composite I Truss iConsult truss manufacturer for recommended installation point. `Pre-drilling may be required for Model SWG 25-380.Tool available on page 11. 4` Watch a video demonstrahon al ''''.° www.itwbuildex.com Rod Part Model Screw Ultimate UL Test Box Case Approvals Size Number Descriptions Pullout(lbs) Load(lbs) Qty Qty HORIZONTAL MOUNT 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 L... :a a,.'.' „, e Cwl :... `IEg ;-" ..v . ,,.�25 '"I dlF I I 3/8" 8021957 SWG 20 1/4 x ry. 2" 1725 (Fir) 1050 25 125 — $ 1i0 -, G' ,t ,1 : r Vii. 5 7125,.. : 3/8 8022925 SWG 25-380 3/8 x 2-1/2" 2249 (Fir) 1500 25 125 it,-, C #14 SW Red '.. 1-,.... .,�>' ' 4 i`, T �,, a .- . Nut Driver Part#8114910 *May require pre-drilling;consult joist manufacturer. SAMMYS SWIVEL HEADTM FOR WOOD - Swivel Application , • Application Product Features j OR RAFTER •Eliminates distortion of threaded rod. afatcsrio P •Accommodates up to 3%"x 12 pitch roof. •Allows 17°deflection from vertical. ROD •Saves time from traditional methods. •Reduces installation costs. .. • x U rucumLE� ( ( •Made in the U.S.A. I NI Approvals Rod Part Model Screw Ultimate UL Test Load FM Test Min Box Case Size Number Descriptions Pullout(lbs) (lbs) Load(lbs) Thickness Qty Qty SWIVEL MOUNT -#14 Black Q,...<> 3/8" 8139957 SH GST 20 1/4 x 2 1257(Fir) 1050 1475 25 125 i' . Nut Driver ' ' }` �' 1 St `. i ri ); . 3-.,. t 7,-<,, rb14 .,' a" .iiiitg,27 k. r4 �?ert#8113910 ..1.:�"-44...7%' � � a ', � � � N 1903 Dim.Lumber 1500 .Q, 3/8'* 8269957 SH-GST/CST 20 5/16 x 1-3/4" 1406 @ 45°off vertical 850 @ 45° 25 125 Dim.Lumber I 1 -- °t2 508957 STr 5 . 1406@. ._off $ "May require pre-drilling consult joist manufacturer. • #14 SH Orange a, Nut Driver Part#8273910 a • 5 To find a distributor near you,call 800-BUILDEX § hr77`r .ma {..� .Y f. 9 �r rr t0 ,. .. _ � "", .�,�. ,✓i. .,4 hit .?. .u ;�� za. �.:�'. ...�az..�. _ ��' � � � ,. .,,x ..:,�� W,x ��„ ..;` SAMMYS° FOR WOOD - Vertical Application Application Product Features Not less than 2"nominal width Wood Flooring •No pre-drilling required. •Quick to install using the Sammy Not less than Nut Driver with an 18V cordless 3"nominal drill/driver. thickness(2-1/2") (depth or side Wood Joist ,. of vertical member) � •Saves time from traditional methods. Double Sheetrock a Por vertical use Ceiling •Reduces installation costs. install in center of lower face. Minimum 2"embedment into base •Made in the U.S.A. I material for NFPA 13 compliance. Composite/Truss _ Consult truss manufacturer for recommended installation point. 'Pre-drilling maybe required/or GST 25-380 Tool available on page 11. o a a 1 , Watch a video demonstration at www.itwbuildex.com Approvals Rod rw UmL eeBox Size Number Descriptions Pullout ate(Ibs) Load UT(lbsst) Load FMT(lbsts) Qty Qty VERTICAL MOUNT 1/4" 8002957 GST 100 1/4 x 1" 210 (7/16"OSB) 670 (3/4"Ply) 25 125 tf 8 9�.: G T2t x 60}t _ r m ,:£ 1/4" 8004957 GST 300 1/4 x 3" 2060 (Fir) 25 125 ''',IV.::;;;''..',;:",'*''-".'."-.1,i 157AST f14 r r OS 3/8" 8008957 GST 20 1/4 x 2 1760 (Fir) 850 1475 25 125 j , ;L:, �W,^ , -,•; 5.°" •5,..c$t`t• " t14�",... rf X70:14„,�0 ,., • , .";^._,: .� ,...,.:400ZI a 3/8" 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 #14 Black , °°,r " 4 20"i F : v+ t% w4 1 Nut Driver . .., �3/8 8069925 GST 30-SS 1/4 x 3" 2060 (Fir) 25 125 Part#8113910 rn, , 1/2 8013925 GST 2 1/4 x 2 1760 (Fir) 25 125 x 1/2" 8015925 GST 3 1/4 x 3" 2275 (Fir) 25 125 #14 SW Red Nut Driver Part#8114910 ais ,, (---.______„_ \v/ oHS' MADE IN U.SA SPECIAL NUT DRIVER SYSTEM:The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time.When the face of the driver comes into contact with the material you are installing into,continue drilling until nut driver spins free.Installation is then complete.Warranty requires the use of the appropriate nut driver for installations. For the most up to date information,visit www.itwbuildex.com 4 4,47 , P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 CPVC - COPPER #905 #906 STEEL .. : - OFFSET HANGER 0010 3.100 1 pl - - Y SIZE-SYSTEM PIPE: 3/4"thru 2" MATERIAL-Carbon Steel. FINISH-Mil. Galvanized. LISTING/APPROVAL- Hanger/Restrainer ` s u: WED 203-EX 4231,EX 2551 PATENT-No.6,648,278. .1r, FUNCTION- Support horizontal piping: CPVC,Copper or Steel. L.! Provides listed vertical/horizontal restraint and prevents upward movement of pipe from pendent sprinkler discharge. • Stabilize vertical piping. Hanger/ fire.-- INSTALLATION INSTALLATION- Per these instructions Restrainer Mai Stabilize including NFPA 13, 13R, 13D and CPVC manufacturers instructions. • Install on horizontal or vertical mounting surface. i= Snap over pipe then squeeze strap back allowing pipe to slide freely. �� immomimmlin When #905 threads are exposed in wood,install#906 backing nut. = FASTENERS-UL Listed per NFPA 13 110 WOOD- CPVC pipe-#905 screw-no pre-drill. Copper and Steel pipe-#14 SMS or 1/4"xl 1/2"lag screw- no pre-drill. Thru 5/8" gypsum board- 1/4"x 2"lag screw. STEEL-min. 18 GA. -CPVC,Copper and Steel pipe- 1/4"or#14 Tek Screw. CONCRETE:Required minimum load each fastener= 5(wt)+2501bs. 2 4 4 FEATURES • . o * 1 1/2" Offset-loose fit allows pipe to slide. ,M M. * Common center-line for 3/4" and 1". * Offset edge eliminates abrasion. ^�� *AFCON#905 screw included-5/16"hex head. /l_�_'�' ORDERING-Part#and pipe size. v AFCON#906 backing nut sold separately. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 11/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 CPVC DOUBLE OFFSET HANGER Hanger/Restrainer his • Ji SIZE-SYSTEM PIPE: 3/4"and 1" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- c 4L us LISTED 203-EX 4231 PATENT-No.6,702,236 FUNCTION-Support horizontal CPVC pipe. Provides listed vertical/horizontal restraint and prevents Hanger/Restrainer upward movement of pipe from pendent sprinkler discharge. INSTALLATION- Per these instructions including NPFA 13, 13R, 13D and CPVC manufacturers instructions. is/1 Install on horizontal or vertical mounting surface. FASTENERS-UL Listed per NFPA 13. #904 screw in wood-no pre-drill. FEATURES *Double 1 1/2"offset0 * Common center-line for 3/4" and 1". *Offset edge eliminates abrasion. *Required AFCON#904 screw included-3/8"hex head. ORDERING-Part#and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. CAti 11/13 ZSP:Zig D0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC - COPPER - STEEL HANGER 510 Fastener 0 SIZE qim� 3/4 2.125 1 2.312 Q 1 1/4 3.170 m 1 V2 3.400 2 4.010 ® 2 1/2 4.320 3 5.320 SIZE-SYSTEM PIPE: 3/4"thru 3" MATERIAL-Carbon Steel. FINISH-Mil.Galvanized. LISTING/APPROVAL- ®as 203-EX 4231,EX 2551 LISTED FUNCTION-Support horizontal piping: CPVC,Copper or Steel. Size 3/4" -2"Prevents upward movement of pipe from pendent sprinkler discharge. Stabilize vertical piping. dA INSTALLATION- Per these instructions 11111 MS including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on horizontal or vertical mounting surface. FASTENERS- UL Listed per NFPA 13 in WOOD: 3/4"-3"CPVC pipe-#905 screw-no pre-drill. 3/4"-3" Steel and Copper pipe-#14 x 1 1/2" SMS or Restraint 1/4"x11/2"lag bolt-no pre-drill. in STEEL 3min. 18 GA. �■� 3/4"-3"CPVC,Copper and Steel pipe- 1/4" or#14 Tek Screw. FEATURES ,or * Offset edge eliminates abrasion. / *Retainer dimples secure hanger to pipe duringinstallation. p g pP *Required AFCON#905 screw included-5/16"hex head. Hanger fl ` _ Stabilize ORDERING-Part#and pipe size. %� = , - CAN ALSO BE USED TO REPLACE- #500 Pipe Strap 0 #520 Tin Strap Specific AFCON products arc exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 5/14 • .. 7.g:§100 P.O. Box 3365 South EI Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER ) I 1 thru 4 inch pipe 1/2&3/4 inch pipe LISTED FOR STEEL/CPVC 5 thru 8 inch pipe NFPA 13 UL PIPE ROD 1 WT 5 WT.+250 TEST LOAD 1 3/8 30.75 403.75 750 1 1/4 3/8 43.95 469.75 750 1 1/2 3/8 54.15 520.75 750 SIZE-ROD-3/8"or 1/2" SIZE-SYSTEM PIPE- 1/2" thru 8" 2 3/8 183 841 634.755 750 2 1/2 3/8 118.35 841.75 850 MATERIAL-Carbon Steel,Mil.Galvanized to G-90 spec. 3 3/8 162.30 1061.50 1050 LISTING/APPROVAL- 4 3/8 246.00 1480.00 1500 COUs 5 1/2 349.45 1996.75 2000 LISTED 203-EX 2551 1"-8" 6 1/2 476.35 2631.75 2650 FM Approval guide-1"-8" 8 1/2 711.00 3805.00 4050 OSHPD OPA-0601 See Website. CONFORMS WITH:Federal Specification WW-H-171E,Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE-650°F. FUNCTION-Pipe hanger component of an AFCON hanger. To support steel,CPVC or copper pipe. INSTALLATION-Per NFPA 13, 13R, 13D,these instructions and the CPVC or copper pipe e manufacturers instructions. TT PA B I• 1 .8793 2.5259 FEATURES- I „1/4 2.1382 2.795 * Sized and listed exclusively for use with#310 Surge Restrainer. „/2 2.2673 2.9,40 * Band edge is offset for EASY pipe insertion. A B 2 2.648 3.2516 * 2 3/2 3.7845 4.111 Custom fit swivel nut for better retention in ring. 3 3.7845 4.43171 \ i i ORDERING-Part#,pipe size. 4 4.3582 4.9992 8 7.5768 8.3190 8 7.5768 8.3290 a _� 11/09 DO P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32" 17/32" O, ‘1-,,,1 I IN raiii . ,, ,1 1,ift,il ii,. ee 1'10 i ,...,9 its 077D DUCTILE BASE PLATE 077S STEEL BASE PLATE SIZE-BRACE PIPE: 1" and 1 1/4" Sch.40 MATERIAL-Carbon Steel,Ductile Iron or S.S.(Type 304). FINISH-Plain or E.G. LISTING/APPROVAL- D 4i DS 203A-EX2625 FM FM Approved-1950 OSHPD See Website. LISTED FUNCTION- Structure attachment fitting of an AFCON sway brace assembly. eas Max. Horizontal Load LISTED Sway brace assemblies are intended to be installed in accordance with Size 1-1 1/4 2015 NFPA 13 and the manufacturer's installation instructions. INSTALLATION-Per these instructions including NFPA 13 or FM 2-8. Load rating-see chart. ASSEMBLY Combine with proper AFCON components-see disclaimer below. Insert brace pipe thru fitting near pivot bolt. 0 Max.Horizontal Load Tighten set bolt until head contacts bracket. FEATURES 30-44° 45-59°60-74°75-90° * Swivel allows attachment at any angle. *Visual inspection,verifies proper installation. Size 1-1 1/4 630 870 1620 1810 *Larger fastener hole available.-Consult factory. ORDERING-Part#,size-brace pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCON products have been,or are used. 9/14 • X001 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING Part#077-........ V, 41 7 Part#078 / �i " %" � r SIZE-SYSTEM PIPE:Nominal Pipe Size ,\JII .v l // Sch.40 Steel 1"- 12" a,,_. Sch. 10 Steel 1 1/4"- 12" Sch. 7 Steel 2"-6" MATERIAL-Carbon Steel or S.S.(Type 304) FINISH-Plain or E.G. PATENT-No.7,140,579 LISTING/APPROVAL ®Listed Max.Horizontal Load 1"-10" 2765 cas 203A-EX 2625 ® FMA roved-1950 12" 3740 OSTEO APPROVED PP FUNCTION-Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. ©certified Max.ASD Horizontal Load INSTALLATION- Per these instructions SNPS Sch. 30°44° 45°-59° 60°-74° 75°-90° including NFPA 13 or FM 2-8 1"-1 1/2" 10-40 420 510 570 Load rating-see chart. 2"-3" 7-ao 860 1030 1150 ASSEMBLY-See drawing. 4" 7-40 860 1030 1150 5" 7-40 950 1150 1280 Combine with proper AFCON components-see disclaimer below. 6" 7-40 2220 2220 3040 Align brace member parallel to face of 411 fastener flanges. 8" 10-40 1340 1620 1810 Tighten 1/2"bolts until fastener flanges connect. FEATURES * Patented-design eliminates bending of fastener flanges during installation. * Patented-design prevents over tightening on system pipe. * Improved assembly-fastener flanges connect for superior strength. * Visual inspection-proper installation when 411 fastener flanges connect. ORDERING-Part#,size-system pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. i di' fit . 5/14 zi7 ' P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 078 ATTACHMENT FITTING LOCKING ® Part#077 1r, 9/16 Dia. 0 0 AVI, it, Part#078 fli, rk a °r Part#410/411— SIZE-BRACE PIPE: 1"and 1 1/4" Sch.40 MATERIAL-Carbon Steel or S.S.(Type 304). FINISH-Plain or E.G. `�J LISTING/APPROVAL- DOUS 203A-EX 2625 <> FM Approved-1950 OSHPD See Website. LISTED FUNCTION-Structure attachment fitting of an AFCON sway brace assembly. Common transition component with 411 sway brace fitting-see drawing Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION- Per these instructions including NFPA 13 or FM 2-8. 0 Max. Horizontal Load Load rating-see chart. 30°-44° 45°-59° 60°-89° 90° DO NOT BEND-If angle required use part 070,075,076 or 077. 1008 1425 1745 2015 ASSEMBLY Combine with proper AFCON components-see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. 0 Max. Horizontal Load FEATURES30°-44° 450-59° 60°-74° 75°-90° *Visual inspection,verifies proper installation. 430 620 760 940 *Bolt hole fits 410/411 sway brace fitting. ORDERING-Part#,size-brace pipe and finish. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners,resulting in a listed sway brace,restrainer or hanger assembly. Be advised the following warranty restriction will apply.DISCLAIMER-AFCON will NOT warrant against the failure of its products when used in combination with other products,parts or systems not manufactured or sold by AFCON.AFCON shall NOT he liable under any circumstances whatsoever for any direct or indirect,incidental or consequential damages of any kind,including but not limited to loss of business or profit,when non-AFCONproducts have been,or are used. ,t. 4/14 .. vffigio,§j1 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 400 RISER CLAMP IRON PIPE r --^ A PIPE STOCK MAX.REC. It— „., SIZE A B C SIZE LOAD LBS. 1 i 1 1/2” 10 3/8" 3/8" 1 1/2" 3/16"x1 1/4" 255 us era 2" 10 3/4" 3/8" 2" 3/16"x1 1/4" 255 2 1/2" 11" 3/8" 2 1/8" 1/4"x1 1/4" 390 ci IS! 4111 3" 12" 3/8" 3 1/4"x11/4" 530 ! \ 3 1/2" 13" 1/2" 3 5/16" 1/4"x1 1/4" 670 B B 4" 13 1/2" 1/2" 3 3/8" 1/4"x1 1/4" 810 5" 14 1/2" 1/2" 4" 1/4"x1 1/2" 1160 6" 15 1/8" 1/2" 4 1/2" 1/4"x2" 1570 8" 18 1/2" 5/8" 5 13/16" 318x2" 2500 NOTE:MAXIMUM TEMPERATURE:650°F 1111 SIZE- 1/2 thru 20 inch pipe. ‘i MATERIAL-Carbon Steel. FINISH-Plain,E.G.,H.D.G. and S.S. LISTING/APPROVAL- cwQs EX 2551 11/2"-8"pipe. OSHPD OPA-0601 See Website. 0 CONFORMS WITH: Federal Specification ,`��`1 WW-H-171E,type 8,3/4 thru 20 inch,and Manufacturers Standardization Society SP-69,type 8. FUNCTION-Used for supporting vertical piping. ORDERING-Part#,pipe size and finish. 1/08 IPS CARBON STEEL PIPE FIRE PROTECTION PRODUCTS ; ,, .„' 4 FireLock® Zone Control Riser Module SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS SERIES 747M Designed for NFPA 13 commercial requirements,the Victaulic Series 747M Zone Control Riser Module features a cast body,and is compact and easy to install in zoned wet sprinkler systems. 1` , The integrated module body consists of a shut off valve,test and drain valve combination and 4 different orifice sizes(K factors),a UL Listed and FM Approved Flow Switch,and a Pressure Gauge.The Series 747M FireLock Zone Control Riser Module is available in sizes from 11/4 through 6"/32mm-150mm with grooved ends on the main pipe for installation in the horizontal or vertical up-flow positions with UL Listed, FM Approved Victaulic grooved couplings.11/4-2"modules have an NPT drain port.2 l -6"modules have a grooved drain port. The Series 747M FireLock Zone Control Riser Module is FM Approved and UL and ULC Listed for working pressures up to 365psi/2517 kPa.An optional pressure relief valve kit is available STYLE 747M for all sizes.The Pressure Relief Valve is FM Approved and UL and ULC Listed for working PATENT PENDING pressures up to 175psi/1200kPa. DIMENSIONSx we • Module Body Size Dimensions Inches/mm Apr Eachfgh A t No' 1 seder ' .1. Diamiter Dianteter/i/i Drain . . ' .. ncfie inches/mm 11 m $ " 1Gi o� 1 0 0 64.5 6 1 /4 1.660 1 11.45 7.20 i 5.77 3.50 i` 10.05 7.482 D )� } 32 42.2 33.4 290.8 182.9 146.5 88.9 i 255.3 9 i it t,r1, a" - C 1'/z 1.900 1 11.45 7.32 5.77 3.50 10.05 7.48 2.54 15 5 F 40 48.3 33.4 290.8 185.9 146.5 88.9 255.3 190.0 64.5 7.0 7• "i 2 2.375 1 11 45 7 55 5.77 3.50 10.05 7.48 2 54 19.9 „ 50 60 3 33 4 290.8 191.8 146 5 i 88.9 255.3 190.0 64.5 9.0 2'/2 2.875 1'/4 12.00 8.41 i 618 4.25 i 9.76 11.87 4.25 22.7 E G 65 73.0 42 305 214 157 i 108 ' 248 302 108 10.3 - A 3 3.500 1 1/4 12.00 9.42 6.18 4 25 9.76 11.87 4.25 23.2 80 88 9 42 -1 305 239 157 108 248 302 i 108 10 6 1+/,-2"/32-50mm Nominal Sizes _._-_..... _....___._.... ._ ..._.__..._. _._... ._ �. _.....___ 4 4.500 2 12.00 9.90 7.25 5.00 10.15 12.62 4.21 30 3 1111§) 100 114 3 60 305 ( 252 184 127 258 321 107 13 8 6 6 625 2 i 12.00 10.85 8.31 i 6.00 10.15 13.62 4.24 36.7 150 168.3 60 305 276 } 211 i 154 i 258 346 1077 16.7 B EL,Mln PIP Orifices roll pili �� Nominal Size D inches f G -.j C 1.25 K5.6 !� '4 1.5 K5.6 F `; s�_J 1 2 K5.6 2.5 K5.6 K6.9 K8.0 K11.2 3 K5.6 K6.9 K8.0 K11.2 E 4 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 6 K5.6 K6.9 K8.0 K11.2 K14.0 K16.8 A 21/2-6"/65.0-150 mm Nominal Sizes Nominal Size Drain Type Drain Size (Valves shown above in the"test"position. inches Shown with optional Pressure Relief Valve Kit installed) 1.25 NPT 1' Hose Clamp 12 NPT 1 ° ..__.... _. _.._..._. _._.. ,. ._ 2.5 Grooved 1 Y4 Pressure Relief Valve 3 Grooved 1 1/4" Barbed Fitting 4 Grooved Hose Clamp .... 6 Grooved 2" Close Nipple ` Drain Tubing jit Elbow Barbed Fitting Optional Pressure Relief Valve Kit Detail JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com J itauIic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. REV I 10.96 1 FIRE PROTECTION PRODUCTS"_,DEVICES — FireLock° Zone Control Riser Module SERIES 747M MATERIAL SPECIFICATIONS Module Body:Cast from ductile iron conforming to ASTM A-536,grade 65-45-12 with integral Victaulic grooved ends. Finish:orange enamel. Shut-off and Test/Drain Valve:Chrome plated brass ball,S 37700 brass clapper,416SS or 410SS shafts, Delrin orifice,virgin Teflon*,enhanced Teflon and EPDM rubber seals. *Teflon is a registered trademark of Dupont Coupling:Any UL Listed, FM Approved Victaulic IPS-sized coupling may also be used. Note: Couplings not included with product. Waterflow Detector:System Sensor Model WFD/WFDTH vane type waterflow detector with sealed retard,visual switch activation,and mechanical delay adjustment.Cover includes tamper resistant security screws and tool. Note: ULC models WFDA/WFDTHA include cover tamper switch. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • WARNING • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, property damage,or valve leakage. 111• r,1, If you need additional copies of this product literature or the valve installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA,Telephone:001-610-559-3300. For complete contact information,visit www.victaulic.com 10.96 3089 REV I UPDATED 7/2010 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.©2010 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ICta'lUI1C@ 10.96 FireLock® Check Valves ✓4taulic Series 717 & 717H 10.08 Grooved ends allow fast, easy installation with just two Victaulic couplings or the valve may be mounted two; to flanged (ANSI CL.150) equipment using either to 1180. Victaulic Style 741 Vic-Flange®or Style 744 FireLock Lt flange adapters on either end. Series 717 Series 717 (21/2—3'/65—80 mm) (4—12'/100—300 mm) Series 717H High Pressure Check Valve (2-3'/50—80 mm) Approvals/Listings: cCI us ® LPCB C}' LISTED See Victaulic Publication 10.01 for more details. The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD designed for hydrodynamic efficiency and available in 2"/50 mm —3"/80 mm (Series 717H) and 2 1/2"/65 mm — 12"/300 mm (Series 717) sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs, the single-disc mechanism incorporates a spring-assisted feature for nonslamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ft/1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically (flow upwards only) or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date Check Valve I Firelock® I Series 717 & 717H I Publication 10.08 ✓ctaulice victaulic.com 1 Check Valve I Firelock® I Series 717 & 717H I Publication 10.08 Material Specifications: Spring: All sizes Type 302/403 Stainless Steel Housing: Shaft Plug: Ductile iron conforming to ASTM A-536, grade • Series 717H (2—3750—80 mm): Type 416 Stainless 65-45-12. Ductile iron conforming to ASTM A-395, Steel grade 65-45-15, is available upon special request. • Series 717 (2 'h— 12765—300 mm): Carbon steel Body Coating: zinc plated Series 717H Body: Black Paint Pipe Plug: Series 717H Endface: Electroless Nickel Series 717 (2 '/z—3"): PPS Coating • Series 717H (2—3"/50—80 mm): carbon steel zinc Series 717 (4— 12"): Black Paint plated • Series 717 (4— 12"/100—300 mm): Carbon steel zinc Body Seat: plated Series 717H — Nitrile 0-ring installed into an electroless nickel plated endface Series 717 (2 'h—3"): PPS Coated ductile iron Series 717 (4— 12"): Electroless Nickel plated Disc Seal or Coating: (specify choice') ❑ Grade "T" nitrile (Series 717H Only) Nitrile(Orange color code).Temperature range—20°F to +180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot, dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. ❑ Grade "E" EPDM (Series 717 Only) EPDM (green color code). Temperature range-30°F to +230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. ' Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3750—80 mm): CF8M Cast Stainless Steel • Series 717 (2 'h—3"): Aluminum bronze with elastomer seal • Series 717 (4— 127100—300 mm): Elastomer encapsulated disc with electroless nickel plated seat Shaft: • Series 717H (2—3"/50-80 mm): Brass • Series 717 (2 'h—3"): Type 416 Stainless Steel • Series 717 (4— 127100—300 mm) Type 316 Stainless Steel victaulic.com 2 ✓ctaulic° Check Valve I Firelock! I Series 717 &717H I Publication 10.08 Approval/Listing: Approval/Listing Service Pressures Series 717H Size cULus FM LPCB Vds 2"/50 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 21/2"/65 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 76.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 3"/80 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 4"/100 mm n/a n/a n/a n/a 5"/125 mm n/a n/a n/a n/a 139.7 mm n/a n/a n/a n/a 6"/150 mm n/a n/a n/a n/a 165.1 mm n/a n/a n/a n/a 8"/200 mm n/a n/a n/a n/a 10"/250 mm n/a n/a n/a n/a 12"/300 mm n/a n/a n/a n/a Approval/Listing Service Pressures Series 717 Size cULus FM LPCB Vds 2"/50 mm n/a n/a n/a n/a 21h"/65 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 3"/80 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa up to 16bar/232 psi 4"/100 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 5"/125 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 139.7 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 6"/150 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 165.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa n/a 8"/200 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi 10"/250 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a 12"/300 mm up to 250 psi/1725 kPa up to 250 psi/1725 kPa up to 1725 kPa/250 psi n/a ✓ctaulhcc victaulic.com 3 Check Valve I Firelock° I Series 717 & 717H I Publication 10.08 • Dimensions- Series 717: < A -r R 1-4- 3 14 !IPA!, v/s I ? I� t � � �l��� M��I� E CI V II �� ° t A I r B � � .. IID E 1 4-B-->I © I <-K---�I 01 O ; lip C 0 1/2"NPT Upstream Drain 01/2"NPT Upstream Drain "-4.-.)-- W Y"NPT Downstream Drain 0 2"NPT(Drain Optional) ®Yz"NPT Downstream Drain Typical 2'1-3"/65-80 mm Typical 4-87100-200 mm Typical 10-12'/250-300 mm Actual Dimensions Approx. Nominal Outside E to E Weight Size Diameter A B C D E J K P R Each inches inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm mm kg 211 2.875 3.88 4.26 3.57 - - 3.6 -65 73.0 99 108 911.6 76.1 mm 3.000 3.88 4.26 3.57 _ _ 3.6 -76.1 99 108 91 1.6 3 3.500 4.25 5.06 4.174.5 80 88.9 108 129 106 - - - - - - 2.0 4 4.500 9.63 6.00 3.88 2.75 3.50 2.00 4.50 3.50 3.35 20.0 100 114.3 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 _ 4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 12.3 5.500 10.50 6.80 4.50 - 4.17 2.15 5.88 4.08 3.98 27.0 139.7mm 139.7 267 173 114 106 55 149 104 101 12.3 6 6.625 11.50 8.00 5.00 _ 4.50 2.38 6.67 4.73 3.89 38.0 150 168.3 292 203 127 114 61 169 120 99 17.2 6.500 11.50 8.00 5.00 - 4.50 2.38 6.67 4.73 3.89 38.0 165.1 mm 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 _ 100.0 250 273.0 432 305 180 151 170 55 277 171 45.4 12 12.750 19.50 14.00 8.06 6.91 7.64 2.51 12.81 7.73140.0 - 300 323.9 495 356 205 176 194 64 925 196 63.5 Dimensions - Series 717H: A .4--B-s• IC J I�pE CO)-7- 4-R 4-J Typical 2"/50 mm-3"/80 mm Dimensions Approx. Nominal E to E Weight Size A B C D E J K P R Each inches inches inches inches inches inches inches inches inches inches lbs. mm mm mm mm mm mm mm mm mm mm kg 2 8.66 6.46 3.23 1.48 3.02 2.80 _ - 4.25 10.7 50 219.8 164.1 82.1 37.5 76.7 71.0108.0 4.9 211 9.37 6.94 3.31 1.66 3.40 3.38 _ _ 4.38 13.8 65 238.0 176.3 84.1 42.2 86.4 85.9 111.3 6.3 76.1 mm 9.37 6.94 3.31 1.66 3.40 3.38 - - 4.38 13.8 238.0 176.3 84.1 42.2 86.4 85.9111.3 6.3 3 9.62 7.44 3.53 1.91 3.65 3.38 _ - 4.63 20.0 80 244.3 189.0 89.7 48.5 92.7 85.9117.6 9.1 victaulic.com 4 ✓ctaulic" Check Valve I Firelock® I Series 717 & 717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. 5717H/717HR 10 4 ' 'c'( 14 . F .. ; • rto k a 10 100 1000 Flow—GPM S717H/717HR 100 00 - .1 F $q i F co [ ' "€ I b F 3 s k Y £ F FF ^�^ F.n_ F F # I € F t ro $ a> b F F F yvtzt ^ r \ h0 .to I �,.� i.; 10 100 1000 100 0 1 000 Flow Rate—Litres/min. victaulic.com 5 ✓ctaulic Check Valve I Firelock® I Series 717 & 717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. 5717/717R 10 N S. FR M, a I e 6 F yo .\ I? I_. € J 1 r f I ''V(' 1 �,•~ hF ,o\ i 1 £ ( ` I g — ; t I # I 1 1 } 1 .. # 4111 ` I , 3 ...# .., 1 1 1 E , i t � " I 0.1 4.— I 10 100 1000 10000,., .., .. w 100000 Flow—GPM 5717/717R 10 5µ y } w �6F , , . ,,,L; , # i i a• r....- - I i i. ...� i---,,s moo 4r .4 .. F ,e' ..goo. , - E I i .. ,....<:-. FF'" F h� �c 1 , M" N N I i s 1 I h ! 'N O 1$ \ 1 ## O l ""r • a r" .. L' s.,_. .. - ..._ .'1.7- ...m J a I I ;' 1 .. t I , 1 ,.I' I i ' i 1 1. s L.1...:11. ._.__ _�.r .1_1.1_1.11 0.1 .._. 1d 10 100 1000 10000 100000 Flow—GPM Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing.Handbooks are included with each shipment of Victaulic toThis product shall e accordance wmanufactith currentd by Victaulic or to Victaulic specifications.elynsr All products products for complete installation and assembly data,and are available in PDF format Victaulic be installed inthe ightto changeh p Victaulic einstallation/assembly an intandar ns. on our website at www.victaulic.com. reserves the right product specifications,designs and standard equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and FireLock are registered trademarks of Victaulic Company. 10.08 1479 Rev.R Updated 05/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 ✓ctaulic" • FireLock® Buterfly Valve ✓ctaulic Style 705 with Weatherproof Actuator 10.81 Material Specifications: Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2 — 6150 — 150 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer, 8 — 12"/200— 300 mm: Ductile iron conforming to ASTM A-536, grade 65-45-12 Approvals/Listings: Coating: Black alkyd enamel c 4l us vds LPCB Disc: Ductile iron conforming to ASTM A-536, grade O ® #G410001 104j/04 65-45-12, with electroless nickel coating conforming to See Victaulic Publication 10.01 for more details. ASTM B-733 Seat: Product Description: ❑ Grade "E" EPDM The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems: 416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed Stem Seal Cartridge: C36000 brass for fire protection services only. Victaulic FireLock Series 705 Butterfly Valve is cULus Listed, LPCB Listed, Bearings: Stainless Steel with TFE lining FM and VdS Approved for 300 psi/2068 kPa service. Contact Victaulic for details of agency approvals. Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: ❑ 2—8"/50—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing El10— 12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. 1 �CtauliC victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2"/50 mm up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 21h"/65 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3"/80 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6'/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8"/200 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ✓ictaulic* victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Dimensions: • /41061- i i. wromilmill 1 ger OH riiiAil= 1. - I. 1 II O I I FJ� .I G E A +-D NOTE:OPTIONAL i '/15MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. Dimensions Actual Nominal Outside E to E D E F G DIA H J Size Diameter A B C inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 _ - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21h 2.875 3.77 2.28 7.54 _ _ 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3.000 3.77 2.28 7.54 - _ 4.00 4.22 4.50 1.77 76.1 mm 76.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 _ - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 4.250 4.63 2.88 8.81 _ - 5.50 4.22 4.50 2.20 108 mm 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 3.35 10.88 _ - 6.56 6.19 6.30 2.58 133 mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 5.500 5.88 3.35 10.88 - _ 6.56 6.19 6.30 2.58 139.7 mm 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 6.250 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 159 mm 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6.500 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 165.1 mm 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 _ 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 _ 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. �CtaL1�iIC victaulic.com 3 • victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 50 60.3 1.8 2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulic® victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 • Performance: Cv values for flow of water at+60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C,values Formulas for K„values Where: AF=Q2/K 2 Where: AP=CV/C,/ v Flow Coefficient CQ Kv x VAP Flow Factor Kv Q=CvxVAP Q(Flow) GPM Q(Flow) m'/hr AP(Pressure Drop) psi AP(Pressure) bar Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches cv inches inches Kv mm mm mm mm 2 2.375 170 2 2.375 147 50 60.3 50 60.3 21 2.875 260 21/2 2.875 65 73.0 65 73.0 225 76.1 mm 3.000 260 76.1 mm 3.000 225 76.1 76.1 3 3.500440 3 3.500 380 80 88.9 80 88.9 4 4.5004 820 100 1143 710 100 114.3 . 108mm 108mm 820 108mm 108mm 710 5 5.563 1200 5 5.563 1040 125 141.3 125 141.3 133 mm 133 mm 1200 133 mm 133 mm 1040 139.7 mm 5.500 1200 139.7 mm 5.500 1040 139.7 139.7 6 6.625 1800 6 6.625 1560 150 168.3 150 168.3 159 mm 159 mm 1800 159 mm 159 mm 1560 165.1 mm 6.500 1800 165.1 mm 6.500 1560 165.1 165.1 8 8.625 3400 8 8.625 2940 200 219.1 200 219.1 10 10.750 5800 10 10.750 5020 250 273.0 250 273.0 12 12.750 9000 12 12.750 7790 300 323.9 300 323.9 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ictaulic victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: ULLISTED (UNCTION BOX • CONDUR ', 1. The supervisory switch contains two single pole, \ ilie:4.«,_ double throw, � //% �=� . pre-wired switches. ��.�" ,NPT 2. Switches are rated: ®I CONDUIT CONNECTORS `� WIRE NUTS 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC FIRE ALARM TO ENp-OF-LINE RESISTOR, 0.25 amps @ 250 VDC CONTROL PANEL ORNF INDICAT°R SUPERVISORY CIRCUIT 3. Switches supervise the valve in the "OPEN" position. °M SWITRA CONTACT RATING: 5. ION AT 125 AND One switch has two#18 insulated wires per terminal, OVAC, 0 5A0.25 AT 125 VDC, 025 AT 250 VDC , which permit complete supervision of leads (refer BELL NE um m OR to diagrams and notes below). The second switch VOLTAGE SOURCE HORN has one#18 insulated wire per terminal. This double swua,:2,tddP<„<r 7: 5wl,a,z:,I<,a�<„<�1nal circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow—S1 and yellow-with- orange stripe—S2) and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue—S1 and blue-with-orange stripe—S2). In this Switch #1 = S1 example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires (e.g. brown with orange stripe). Switch #2 = S2 Only S1 (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in Normally Closed: (2) Blue accordance with NFPA 72 and the auxiliary switch per s1 NFPA 70 (NEC). Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. • 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 \ICtaulic' FireLock NXTTM Dry Valve ✓ctaulic Series 768 30.80 ,01w • —. Patent Pending Certifications/Listings: ® LPCB C C C US 104f/01 0832VdS MEA 248-98-E See Victaulic Publication 10.01 for more details. Product Description: The patent-pending Victaulic Series 768 FireLock NXT Dry Valve is a low differential, latched clapper valve that uses a unique direct acting diaphragm to separate system water supplies from dry-pipe sprinkler systems. 1 see page 12 for European trim Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. 1 ictauIic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Features: The low differential, unique latch and actuator design of the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns. The valve allows the water to operate a water motor alarm and/or electric pressure alarms, which Clapper continue until the flow of water stops. With the optional C � `.�` 'Latch accelerator, the valve can be configured to respond 1, �, faster for use in larger systems, or where faster response I 0 ( times are required. k (, y, /;;41. _ ,,.••° Diaphragm The valve is rated to 300 psi/2065 kPa water working kk \f-\-.zzza q,11,Y r a� Assembly �I�—� - ;�I�=� pressure and is factory tested hydrostatically to 600 psi/ bv'' �r --- 4135 kPa for sizes 1 1—8"/40—200 mm. VdS trim 'AW% Clapper Seal configurations are approved to 16 BAR (see page 12). j `Seat Required air pressure for all trim variations is 13 psi/ 90 kPa. The Series 768 is available grooved x grooved. Exaggerated for clarity Standard grooved dimensions conform to ANSI/AWWA Note:Valve is shown in the"set'position C606. The Victaulic Series 768 FireLock NXT Dry Valve is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. All internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve. The valve is painted inside and out to increase corrosion resistance. The body is tapped for main drain and all available trim configurations. Installation Options The Victaulic Series 768 FireLock NXT Dry Valve is available bare, or in the following configurations: Pre-trimmed The pre-trimmed valve comes completely assembled with all necessary trim components. Vic-Quick Riser The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve (uses a Series 705W FireLock Butterfly valve— request publication 10.18; for 1 lh and 2"/40 and 50 mm sizes, the Vic-Quick Riser comes with a Series 728 Ball Valve— request publication 10.17) for system shut off, pre-set pressure switches, and a drain kit for ease of installation. For complete Vic-Quick Riser information request publication 30.20. Series 745 FireLock Fire-Pac (Available in North America only) The Fire-Pac is a completely pre-assembled fire protection valve that provides maximum service in a minimal enclosed space. The unit includes a water supply shutoff valve, the sprinkler system fire protection valve, alarm line pressure switches, air supervisory pressure switches, supervisory pump switches, and digital pressure gauges that are easily viewed through a window in the cabinet door. For complete Fire-Pac information request publication 30.23. Optional accessories ship separately. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic' victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Dimensions: The 4 Inch/114.3 Mm UI Listed, FM Approved Configuration Is Shown Below 11/2-2'/48.3-60.3 mm Configurations Contain 3/4"/19 mm Drain Valves. 2 1-3'/73.0-88.9 mm Configurations Contain 11/4"/31 mm Drain Valves. 4-8'/114.3-219.1 mm Configurations Contain 2'/50 mm Drain Valves. r, I I I 1 A A I� n •, I,; fiofi ao 'eN r 1 - I r' `'1, F--� I -4 F--41 .a. A A 1 1 • G J =I. ._ .:-j:-l.l' 7L-N u_1' �Inl -a1 , .: iI ,_ 1._ F nc.;1:-I Millit �MI ni L1-U li� IiI fI ' I D "D1 q A A Li ! -p■: i I lit 1 Ti tiki * 1 if lisq)li r irp .e..: �U���[CSS : 1 ,�tf� _ i ii f-117) aim 44-tekt1 1141 am.1_i. .Al SFO ►' ' X11 II�V% '� �` rr-I elt--'i =_ � -■: I--J o ill'-a I 11 rr l = _ i.. =i I II i--i5 IA11 1=1.--:I --wk., -- �r� I I II i r1 f'---I, I it ' •=-MIC � Flt,�__i�'� - ji I IOW a is; J T-- El 01.11.11,11111,E H ► 4- K ) C >< *El -). Full Open Approx. Weight Dimensions Each Actual Nominal Outside Without With Size Diameter A Al B Bl C 0 Dl E El F G H J K Trim Trim inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches inches lbs. lbs. mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm mm kg kg 11 1.900 9.00 16.35 27.25 39.50 13.75 16.00 _ 5.25 8.50 9.50 21.25 3.04 9.17 6.98 16.7 43.0 40 48.3 228.60 415.29 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.6 19.5 2 2.375 9.00 13.37 27.25 39.50 13.75 16.00 _ 5.25 8.50 9.50 21.25 3.04 9.17 6.98 17.0 43.0 50 60.3 228.60 339.60 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.7 19.5 21/2 2.875 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 65 73.0 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 76.1 mm 3.000 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 76.1 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 3 3.500 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 80 88.9 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5 4 4.500 15.03 19.83 33.50 45.50 15.00 15.75 20.50 5.25 9.00 10.75 21.00 6.25 9.62 8.46 59.0 95.0 100 114.3 381.76 503.68 850 1155 381 400 520 133 228 273 533 158.75 244.34 214.88 26.7 43.0 165.1 mm 6.500 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 165.1 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6 6 6.625 16.00 22.05 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 150 168.3 406.40 560.07 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6 8 8.625 17.50 23.00 33.50 45.50 16.75 20.00 25.25 6.25 8.75 12.75 18.50 6.05 9.40 10.21 122.0 158.0 200 219.1 444.50 584.20 850 1155 425 508 641 158 222 323 469 153.67 238.76 259.33 55.3 71.6 NOTES: The"A"dimension coupling is not shown in order to clarify dimensional callouts. Components shown as dotted lines denote optional equipment. Measurements denoted with an asterisk take optional equipment into account. Optional drain connection kit is shown for reference and takeout dimensions. • 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Performance: Hydraulic Friction Loss The chart below expresses the flow of water at 65°F/18°C through a full open valve. 6.0 4.0 , F o .ti+P 1 ,,,• . HI li 2.0 w.. .'_ a D _ v rn l 6 e° m° _o l # d g \.off \eye of o f i !o �1 I .1 ' ` i i a i ,. tib,. ��1 a, 1 l !i 1.0 r , 0.9 t D U.7 w 0.6 .I m.. wI I�. i E uI " i' ii 1 I I i 1 1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000 800 3,000 8,000 FLOW RATE—GPM Frictional Resistance The chart below expresses the frictional resistance of Victaulic Series 768 FireLock NXT. Dry Valve in equivalent feet of straight pipe. Actual Equivalent Nominal Outside Length of Size Diameter Pipe inches inches feet mm mm meters 11/2 1.900 3.00 40 48.3 0.914 2 2.375 9.00 50 60.3 2.743 21 2.875 8.00 65 73.0 2.438 76.1 mm 3.000 8.00 76.1 2.439 3 3.500 17.00 80 88.9 5.182 4 4.500 21.00 100 114.3 6.401 165.1 mm 6.500 22.00 165.1 6.706 6 6.625 22.00 150 168.3 6.706 8 8.625 50.00 200 219.1 15.240 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 4ictauliC® victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 C,Values: Operation: C„values for flow of water at+60°F/+16°C through a fully The Series 768 Dry Valve contains a clapper, which has open valve are shown in the table below. a replaceable rubber seal. The clapper makes contact with the valve's seat ring, which has access Formulas for Ct,values Where: holes leading into an intermediate chamber in the valve. oP=Q2/Cv2 Flow Coefficient C, The diaphragm contacts the latch, and the latch holds Q=c X VAP Q(Flow) GPM the clapper closed. AP(Pressure Drop) psi In the closed position, the valve diaphragm is maintained in the extended position by the water supply pressure from upstream of the water supply control valve. The diaphragm latch holds the clapper in the closed position. The Series 776 Low Pressure Actuator (LPA) maintains Valve Size Full Open the water, and the system's air pressure controls the Actual LPA. Required air pressure is 13 psi/90 kPa. The design Nominal Outside of the 776 actuator does not require the traditional air Size Diameter Flow Coefficient cushion of 10—20 psi/69— 138 kPa. Excess air inches inches c pressure above 13 psi/90 kPa will cause a delay in valve mm mm is, 1'/z 1.900 60 operation. 40 48.3 52.0 Once the system's air pressure reduces to the trip point, 2 2.375 110 the LPA opens and allows the water supply pressure in 50 60.3 95.0 2% 2.875 180 the diaphragm to release (i.e. an open sprinkler). This 65 73.0 156.0 release allows the latch to move to its open position, 76.1 mm 3.000 180 permitting the clapper to pivot freely, thus allowing water 76.1 156.0 into the system. 3 0 80 8a90 173.0500 Water enters the intermediate chamber of the valve ' 4 4.500 350 through the holes in the seat ring. The water flows from 100 114.3 302.8 the intermediate chamber to the alarm line, which 165.1 mm 665.10 1000 activates the system's alarms. The alarms continue to 6 6.625 1000 sound until the flow of water stops. 150 168.3 865.0 When the flow of water stops, the spring-assisted valve 8 8.625 1500 clapper returns to the closed position. The valve acts as 200 219.1 1499.1 an alarm check valve until the system is back in service as a dry system, according to the proper procedure. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 5 ctaulic ' victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Material Specifications: Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Clapper: Aluminum bronze UNS-C95500 Latch: Aluminum bronze UNS-C95500 Shaft: Stainless 17-4 Clapper Seal: Peroxide cured EPDM, ASTM D2000 Bushings/Seat 0-rings: Nitrile Springs: Stainless Steel (300 Series) Diaphragm: Peroxide cured EPDM with fabric reinforcement Bill of Materials 1 Valve Body 12 Cover Plate 2 Clapper 13 Cover Plate Gasket 3 Clapper Seal 14 Cover Plate Bolts* 4 Seal Ring 15 Latch 5 Seal Washer 16 Latch Spring 6 Seal Retaining Ring 17 Latch Spring Bushing and 0-ring(Qty.2) 7 Seal Assembly Bolt 18 Diaphragm 8 Bolt Seal 19 Diaphragm Cover 9 Clapper Spring 20 Diaphragm Cover Cap Screws(Qty.8) 10 Clapper Shaft 21 Latch Shaft 11 Clapper Shaft Bushing and 0-ring(Qty.2) Cr) °11)17 0, 0 ° 0✓ i I 4110 ° i IOIo7C'e ' 1 , cip 0 mw O ,p.->- ,- �t 0 s ,3c(e " 7. c2, 0 t' 0 * NOTE:The 11/2-inch/48.3-mm and 2-inch/60.3-mm valve sizes contain washers under the heads of the cover plate bolts. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 6 Ictaulic victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Trim Package Details: • Air Compressor (See page 8 for more on the Trim Packages: Victaulic Series 7C7 Compressor Package) NOTE: See page 11 for details of trim and page 12 for • Air Maintenance Trim Assembly details of European trim. • Alarm Panels 1 Galvanized components. • Drain Connection Kit 2 Series 776 Low-Pressure Actuator—The Series 776 Low-Pressure Actuator is pneumatically actuated • and requires only 13 psi/90 kPa minimum air Air Supply Requirements: pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low The required air pressure for Series 768 FireLock NXT air or gas pressure of 7 psi/48 kPa. Dry Valves is 13 psi/90 kPa minimum, regardless of the system supply water pressure. Air pressures should be 3 All Required Pipe and Fittings. kept below 18 psi/124 kPa, unless a Series 746-LPA 4 All Standard Trim Accessories. Dry Accelerator is installed. Systems with air pressures higher than 18 psi/124 kPa may require the addition of a 5 All Required Gauges Series 746-LPA Dry Accelerator. Optional Trim Package: If multiple Series 768 FireLock NXT Dry Valves are 1 Black Trim for Foam Systems— If the valve is installed with a common air supply, isolate the systems intended for use in a foam system, black trim must with a spring-loaded, soft-seated ball check valve to be ordered, per NFPA requirements. Specify this ensure air integrity for each system. Good practice is requirement on the order. to include a ball valve for isolation and service of each individual system. The engineer/system designer is responsible for sizing Optional Accessories: the compressor so that the entire system is charged to • Series 746-LPA Dry Accelerator—The Series the required air pressure within 30 minutes. DO NOT 746-LPA Dry Accelerator is required when the oversize the compressor to provide more airflow. An Series 768 Dry Valve is installed in large systems to oversized compressor will slow down or possibly prevent improve response time. Request submittal 30.64. valve operation. • Series 760 Water Motor Alarm—The Series 760 If the compressor fills the system too fast, it may be Water Motor Alarm is a mechanical device that necessary to restrict the air supply. Restricting the air sounds when a sustained flow of water occurs (such supply will ensure that air being exhausted from an open as with an open sprinkler). Request submittal 30.32. sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted. • Series 75B Supplemental Alarm Device—The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device. Request submittal 30.33. • Series 75D Water Column Kit—The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30.34. • Alarm Pressure Switch—Alarm Pressure Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs (such as with an open sprinkler). • Air Supervisory Pressure Switch—Air Pressure Supervisory Switches are used to monitor low system air pressure and are factory pre-set. • Air Supply System —The air supply system contains all components for establishing and maintaining air in the system. The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 7 ictaulic• victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Compressor Sizing: COMPRESSOR REQUIREMENTS 20 psi/138 kPa 13 psi/90 kPa 10 .._...._..,if_ ._.w,_..... ._.. ..__.... .............. .....-._. _,._._...... .--.,....: E I 8 .._ v... W I— �I c . I �. 6 sm, .... -- LL k W I' •' z s I Caci I 00 I '�'��'� I I I p • 0 ^_,,.... ,.....,,...M_....,.,.... O Q .. ... o, O O W ✓ I, O O O 0 O O O SYSTEM CAPACITY(in gallons) Base or Riser-Mounted Compressors: Shop Air or Tank-Mounted Air Compressors: For base or riser-mounted compressors, the recom- In the event a compressor becomes inoperative, a mended air pressure of 13 psi/90 kPa is the "on" or properly sized tank-mounted air compressor provides "low" pressure setting for the compressor. The "off" the greatest protection for systems. or "high" pressure setting should be 18 psi/124 kPa. When shop air or a tank-mounted air compressor is Victaulic offers the Series 7C7 Compressor package used, the Series 757 Regulated AMTA must be installed. for FireLock NXT devices which is riser-mounted and The Series 757 Regulated AMTA provides proper air pre-set for the FireLock NXT pressure requirements as regulation from the air reservoir to the sprinkler system. stated above. For information on the Series 7C7 package, consult publication 30.22. The Series 7C7 For tank-mounted air compressors, the recommended Compressor package is only available in North America. air pressure of 13 psi/90 kPa should be used as the set point for the air regulator. The "on" pressure of the When a base or riser-mounted air compressor supplies compressor should be at least 5 psi/34 kPa above the air to a Series 768 FireLock NXT Dry Valve, it is not set point of the air regulator. necessary to install the Victaulic Series 757 Regulated Air Maintenance Trim Assembly (AMTA). In this case, the airline of the compressor connects to the trim at the fitting where the Series 757 Regulated AMTA is normally installed (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with Pressure Switch should be installed. For information on the Series 757 Regulated Air Maintenance Trim Assembly, see publication 30.35. For information on the Series 757P Air Maintenance Trim Assembly, see publication 30.36. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 8 ictaulia victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Series 757 Regulated Air Maintenance Trim Assembly: • Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series 757 Regulated AMTA Bill of Materials 1 1/2"/3.2 mm Restrictor 2 Slow Fill Ball Valve(Normally Open) 3 Air Regulator 4 Strainer(100 Mesh) 5 Spring-Loaded,Soft-Seated ��• / Ball Check Valve 0 q� O 6 Fast Fill Ball Valve(Normally Closed) Nj -, '67D =' o Zi- Exaggerated for clarity Series 757P Air Maintenance Trim Assembly With Pressure Switch: • Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series 757P AMTA with Pressure Switch • Bill of Materials 0 `� .`/ Item Qty. Description I � % 1 1 Restrictor(1/2-inch NPT) 2 1 Strainer(1/2-inch NPT) o 3 1 Swing Check(1/2-inch NPT) 4 1 Slow-Fill Ball Valve t5 (Normally Open) 5 1 Spring-Loaded,Soft-Seated Check Valve 6 1 Pressure Switch 7 2 Compression Fitting,Straight (1/4-inch NPT x 1/4-inch Tube) 5 /V 0 Elb,8 1 Copper Tubing(1/4-inch OD) �P eq 9 11 Close Nipple � I (1/2-inch NPTx 1.13) 10 1 Nipple(1/2-inch NPT x4.00) `��-• m 11 1 90°Female Elbow(1/2-inch NPT) 12 4 Female Tee(1/2-inch NPT) 13 3 Union(1/2-inch NPT) 14 2 Reducing Bushing (1/2-inch NPTx 1/4-inch NPT) 15 1 Fast-Fill Ball Valve (Normally Closed) `" 0 7 16 1 Pressure Switch Isolation Ball © - m e !1j, E9 Valve(Normally Open- Lockable) I FROM WO COMPRESSOR ,• TO SYSTEM Exaggerated for clarity • • 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 9 �Ictaulnc' victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 • Compressor Requirements: Remote System Test Valve Requirements Compressor Requirements and Settings for Series 768 The remote system test valve (inspector's test connection) FireLock NXT Dry Valves Installed with Series 746-LPA should contain a UL Listed and/or FM Approved valve Dry Accelerators (normally closed), which can be opened to simulate the Set the air regulator of the Series 757 Regulated AMTA operation of a sprinkler. to 13 psi/90 kPa. The remote system test valve (inspector's test connection) THE SERIES 757P AIR MAINTENANCE TRIM should be located at the most hydraulically ASSEMBLY WITH PRESSURE SWITCH MUST NOT BE demanding location in the release system. USED ON A SERIES 768 FIRELOCK NXT DRY VALVE NOTE: Multiple restrictions on the remote system test INSTALLED WITH A SERIES 746-LPA DRY valve (inspector's test connection) may slow the air ACCELERATOR. decay rate and cause the system to respond slower than required. When a Series 768 FireLock NXT Dry Valve is installed with a Series 746-LPA Dry Accelerator, the Series 757 The remote system test valve (inspector's test connection) Regulated AMTA must be used. NOTE: The use of an air should terminate with an orifice equal to the regulator with a base or risermounted compressor could smallest orifice in the releasing system. cause short cycling, resulting in premature wear of the The remote system test valve (inspector's test connection) compressor. is used to ensure that water reaches the most remote In the event a compressor becomes inoperative, a part of the system within 60 seconds. properly sized tank-mounted air compressor provides the greatest protection for systems installed with a Series 746-LPA Dry Accelerator. In this situation, air can be supplied continuously to the sprinkler system for an extended time period. NOTE: The Series 757 Regulated AMTA must be used with a tank-mounted air compressor or shop air system that continually supplies air to a Series 768 FireLock NXT Dry Valve installed with a Series 746-LPA Dry Accelerator. The air regulator of the Series 757 Regulated AMTA is a relief-type design. Any pressure in the system that is above the set point of the air regulator will be released. Therefore, charging the air regulator above the set point could cause premature operation of a valve installed with a Series 746-LPA Dry Accelerator. NOTE: The series 746-LPA should not be used above 30 psi. If higher pressures are required, the series 746 should be used. Settings for Air Supervisory Pressure Switches and Alarm Pressure Switches Air supervisory pressure switches are required for dry systems and must be set according to the following instructions. NOTE: Switches for Vic-Quick Risers are pre-set at the factory. Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition, the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement. Set the air supervisory pressure switches to activate at 2—4 psi/14—28 kPa below the minimum air pressure required, but not lower than 10 psi/69 kPa. Wire the alarm pressure switch to activate a water flow alarm. Set the alarm pressure switch to activate on a pressure rise of 4—8 psi/28—55 kPa. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 10 ictauliC® victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— . Trim Components ( c us ® Trim) LISTED Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Materials 1 Series 768 FireLock NXT Dry Valve 2 FireLock Rigid Coupling(Optional/ 0 Sold Separately—Comes Standard -' when VQR Assembly is Ordered) ^ 3 Water Supply Main Control Valve From System I (Optional/Sold Separately—Comes Air Feed ,---1c i 0Standard when VQR Assembly is Ordered) I 1 / 4 Drain Swing Check Valve __� 5 Drip Cup with Cap - 6 Alarm Pressure Switch(Optional/Sold " Separately—Comes Standard when VQR Assembly is Ordered) l -/ 7 Series 729 Drip Check Valve rSe ® Location 8 Diaphragm-Charge-Line Ball Valve � 0 (Normally Open) -- -i 011 9 3-in-1 Strainer/Check/Restrictor i i�i I W �'i :1 , 0 Assembly �1 L ' 10 Series 760 Water Motor Alarm �'V�� zn ''i� �l�: � � (Optional/Sold Separately) 0 ® r+ �� ° �� 11 Alarm Test Ball Valvej (....,,,- . ,,t,,, 12 Diaphragm-Charge-Line Pressure lie *.• To Drip Cup �, Gauge(0-300 psi/0-2068 kPa/0-20.7 Bar) ♦� j1 4 To Drip Cup Location �l `rJ`��/ ��\� Location A `Lua 13 Series 749 Auto Drain ®0 i.� '� O O 14 Series 746-LPA Dry Accelerator $t`..; % ... 0 Assembly(Optional/Sold Separately) V 15 Series 776 Low-Pressure Actuator ►% Toiii: 16 Air Manifold Note \, System 17 Air Supervisory Pressure Switch \, (Optional/Sold Separately—Comes I\. \• 1 T 0 ° Standard when VQR Assembly is Ordered) I� , \ \• 18 System Pressure Gauge1 , \ �u ��? (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) �i� \' �'� t - 19 Water Supply Main Drain Valve- ® O� i'J`►&�•lw. \'\ it l .. oti. Flow Test w i 20 Water Supply Pressure Gauge ff(�J \V � 'I �- "',. 4���# (0-300 psi/0-2068 kPa/0-20.7 Bar) ;gip \,\ 0 � ;,,. C.'� %Ai 21 Drain Connection Kit(Optional/Sold \ J r;, I.--- Separately—Comes Standard when VQR -i�`, o Assembly is Ordered) �_ , 22 Gauge Valve -- .0 \ r 23 System Main Drain Valve I�.`� i 24 Series 748 Ball Check Valve ° ; lid © r , �\I,� , ITo Drip Cup - -- VLocation n i1 �° IPI 0 From Water Supply Exaggerated for clarity Optional devices include the Series 75D Water Column Device Kit and the Series 75B Supplemental Alarm Kit. NOTE 1:Connection point for the Series 75D Water Column Device Kit. For installation of the Series 75B Supplemental Alarm Device,refer to the instructions supplied with the product. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 11ictaulic' victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 Exploded View Drawing— Trim Components: (European Trim: c 0 us ® LPCB ( vascla, 104f/01 0832 MEA:248-98-E Series 768 FireLock NXT Dry Valve (Optional Accessories Also Shown) Bill of Materials 1 Series 768 FireLock NXT Dry Valve O) IC) 2 FireLock Rigid Coupling(Optional/Sold Separately-Comes Standard when VQR V,�' Assembly is Ordered) From t System , I ... /I 3 Water Supply Main Control Valve(Optional/ Air Feed . !� Sold Separately-Comes Standard when VQR r t�' " i Assembly is Ordered) 0 __; 4 Drain Swing Check Valve 5 Drip Cup with Capiq "J- 6 Alarm Pressure Switch(Optional/Sold � 17 l ' Location Separately-Comes Standard when VQR 0 Assembly is Ordered) 21 7 Series 729 Drip Check Valve L�1 8 Diaphragm-Charge-Line Ball Valve 1 �i�� 1 W Z; (Normally Open) i i / 1 9 3-in-1 Strainer/Check/Restrictor za o Assembly ® ® I �t © `).0c). 3 � J To Drip Cup'PG - 10 Series 760 Water Motor Alarm /+?I `r� To Drip Location (Optional/Sold Separately) „%�� 71�� Cup I®11 Alarm Test Ball Valve ® o-W "9W, `=' ^ Location 12 Diaphragm-Charge-Line Pressure ,,.. "� 0.,; O� ® Gauge(0-300 psi/0-2068 kPa/0-20.7 Bar) "' %1' To EN 13 Series 749 Auto Drain �� v 14 Series 746-LPA Dry Accelerator Note 1 \ system ) Assembly(Optional/Sold Separately) \ lir— 15 Series 776 Low-Pressure Actuator ® �'\ \ ® -� s 16 Air Manifold ,�i A, ��� 17 Air Supervisory Pressure Switch(Optional/Sold j�I- \ �� •�, Separately-Comes Standard when VQR ® ©� `O \, v,,`� Assembly is Ordered) ®' (I ��� ��`°, �j�.i 18 System Pressure Gauge f1Q?J " vi,-- - �� i p.••, (0-80 psi/0-552 kPa/0-5.5 Bar with Retard) -033-4R-49- � j --/\i, ���`�i C 19 Water Supply Main Drain Valve- How Test _ zs 20 Water Supply Pressure Gauge _ '' co-300 psi/0-2068 kPa/0-20.7 Bar) L_,----------- - :' %�� 'vi •P 21 Drain Connection Kit(Optional/Sold ��JJ Separately-Comes Standard when VQR © To Assembly is Ordered) �' ,� Location _ J 22 Gauge Valve "t 23 System Main Drain Valve ��i � ��55 \- , 24 Series 748 Ball Check Valve �;�: � ® ` i 1lF �� 25 Water Motor Alarm Shutoff Valve �,, �� 'r` (Normally Open)* ���� L 'Item 25,water motor alarm shutoff valve,can be closed to prevent water from Flowing , into the Series 760 Water Motor alarm during conditions that are not favorable for the alarm to sound lieduring a trip test). From Water Supply • 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. victaulic.com 12 ✓ctaulic' s victaulic.com I NXT Dry Valve I Series 768 I Publication 30.80 • This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information. 4 Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage. If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O. Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300. Installation Note Reference should always be made to the appropriate Installation,Maintenance,and This product shall be manufactured by Victaulic or to Victaulic specifications.All products Testing Manual included with each shipment of Victaulic products.These manuals are also to be installed in accordance with current Victaulic installation/assembly instructions. available in PDF format on our website at victaulic.com Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic®and FireLock®are registered trademarks of Victaulic Company. 30.80 4219 Rev G Updated 01/2015 ©2015 Victaulic Company.All rights reserved. �Ctc]U�iC® victaulic.com 13