Loading...
Plans (41) SHERMAN A — 3151 NE SANDY BLVD.SUITI ENGINEERING PORTLAND,OR 9 = INC 1 PHONE(503)230- 1 SHERMANENGINEERS. OFFICE COPY RECEIVED .09 PR°Fessi 40 \_„0---: ,N�F D NOVr �.;�. CITY OF TIGARI? 2p�� El b 1 VIEW D FOR CODE COMPLIANCE I r R GON ggyy rr y� G At v o vC , 19� (proved: j ZA / r C y 0, CC: I 1 • °N P sHik0P mit #: rnS-i-.3n J 4- oQ 47 I EXPIRES: 6/30/ 0 !dress: ) 0'7 J E su.r A 41,1 1t.-,.(L 94 lite#: r: Date: )I-07 ' JL SD ® b" O.G. 2X10 BLCK W/ — \�`\ (2) IbD EA END i O FURR WALL OUT AS NECESSARY -- NEW I-3/4"xIS" LSL W/(2) I6d - 10" 0.G. STAGGERED I • I '\ NEW REPLACEMENT SEAM 3-I/2"x11-7/8" PSL EXIST TRUSSES W/ HNGRS TO NEW BEAM 0 RX IS T ROOF TRUSS/\6lA( 5EA"CS RFT21 SCALE: I" = I'-O" PROJECT TITLE: SW HIGHLAND DRIVE SEI PROJECT#: 16-MSNV-01-DRPIN NOV , 2016 SHERMAN ENGINEERING, INC. 3151 NE SANDY BLVD BeamChek v2007 licensed to:Sherman Engineering, Inc. Reg#7992-66413 \LIV) 1 10715 SW HIGHLAND DR FRAMING RB1 Prepared by: DPS Date: 11/03/16 Selection (2)1-3/4x 16 1.9E TJ Microllam LVL Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=9.1 in2 R2=9.1 in2 (1.5)DL Defl= 0.49 in Data Beam Span 20.0 ft Reaction 1 LL 4750# Reaction 2 LL 4750# Beam Wt per ft 14.39# Reaction 1 TL 6794# Reaction 2 TL 6794# Bm Wt Included 288# Maximum V 6794# Max Moment 33969'# Max V(Reduced) 5888# TL Max Defl L/180 TL Actual Defl L/194 LL Max Defl L/240 LL Actual Defl L/319 Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl Actual 149.33 56.00 1.24 0.75 Critical 141.77 26.95 1.33 1.00 Status OK OK OK OK Ratio 95% 48% 93% 75% Fb(psi) Fv(psi) E(psi x mil) Fc_i_(psi) Values Reference Values 2600 285 1.9 750 Adjusted Values 2875 328 1.9 750 Adjustments CF Size Factor 0.962 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL:475 Uniform TL: 665 =A CVAA Pb s f rs ! e74/ ET -g- 1,5E6 (S1-42/pi )4- 1 se > 1 coi,4, k) , 10b W- = ''.5 ,A/)2 ') ( b6' .) - ir-r ' ' i- 17- F ! _ 6 E-b 7”, ) ( bs---) = -2L-20 e .T.1_ \iA,,,z-:_ 47 ( al-- 13,41rk. t,4 , Uniform Load A R1 =6794 R2=6794 SPAN=20 FT Uniform and partial uniform loads are lbs per lineal ft. ( `'t2aA ., 0 , ` � (i) @ l0 o. ,> � 4 - SHERMAN ENGINEERING,INC. IIFl IA 3151 NE SANDY BLVD i BeamChek v2007 licensed to:Sherman Engineering, Inc. Reg#7992-66413 10715 SW HIGHLAND DR FRAMING RB1 Prepared by:DPS Date: 11/03/16 Selection 3-112x 11-7/8 2.0E TJ Parallam W.S. PSL Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=4.8 in2 R2=4.8 in2 (1.5) DL Defl= 0.64 in Data Beam Span 19.5 ft Reaction 1 LL 1882# Reaction 2 LL 1882# Beam Wt per ft 12.99# Reaction 1 TL 3139# Reaction 2 TL 3139# Bm Wt Included 253# Maximum V 3139# Max Moment 15305'# Max V(Reduced) 2821 # TL Max Defl L/180 TL Actual Defl L/182 LL Max Defl L/240 LL Actual Defl L/365 Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl Actual 82.26 41.56 1.29 0.64 Critical 55.00 12.69 1.30 0.98 Status OK OK OK OK Ratio 67% 31% 99% 66% Fb(psi) Fv(psi) E(psi x mil) Fc i(psi) Values Reference Values 2900 290 2.0 650 Adjusted Values 3339 334 2.0 650 Adjustments CF Size Factor 1.001 Cd Duration 1.15 1.15 Cr Repetitive 1.00 Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 CI Stability 1.0000 Rb=0.00 Le=0.00 Ft Loads Uniform LL: 193 Uniform TL: 309 =A Uniform Load A /\ 0 R1 =3139 R2=3139 SPAN= 19.5 FT Uniform and partial uniform loads are lbs per lineal ft. ' i SHERMAN ENGINEERING,INC. 3151 NE SANDY BLVOD BeamChek v2007 licensed to:Sherman Engineering, Inc. Reg#7992-66413 10715 SW HIGHLAND DR FRAMING RBI Prepared by: DPS Date: 11/03/16 Selection 1-314x 18 1.55E TJ TimberStrand LSL Lu=0.0 Ft Conditions NDS 2005 Min Bearing Area R1=5.5 in2 R2=5.5 in2 (1.5)DL Defl= 0.51 in Data Beam Span 19.5 ft Reaction 1 LL 2165# Reaction 2 LL 2165# Beam Wt per ft 8.31 # Reaction 1 TL 3552# Reaction 2 TL 3552# Bm Wt Included 162# Maximum V 3552# Max Moment 17316'# Max V(Reduced) 3006# TL Max Defl L/180 TL Actual Defl L/225 LL Max Defl L/240 LL Actual Defl L/442 Attributes Section(in3) Shear(in2) TL Defl(in) LL Defl Actual 94.50 31.50 1.04 0.53 Critical 83.36 13.76 1.30 0.98 Status OK OK OK OK Ratio 88% 44% 80% 54% Fb(psi) Fv(psi) E(psi x mil) Fc (psi) Values Reference Values 2250 285 1.6 650 Adjusted Values 2493 328 1.6 650 Adjustments CF Size Factor 0.963 Cd Duration 1.15 1.15 Cr Repetitive 1.00 • Ch Shear Stress N/A Cm Wet Use 1.00 1.00 1.00 1.00 40"'''' CI Stability 1.0000 Rb=0.00 Le=0.00 Ft lik Loads Uniform LL:222 Uniform TL: 356 =A 4, *041 n V Uniform Load A Z . R1 =3552 R2=3552 Yor SPAN= 19.5FT Uniform and partial uniform loads are lbs per lineal ft. iii,a •,I.