Report RTE
I t BEMt3EE I EPOP T Level, Window Header 1, /,(//).(16- �. �t.',! PASSED
1 1 piece(s)4 x 8 Douglas Fir-Larch No. 2 C 2_( L((, St, ( rill /)
Overall Length:5'3.00'° :.,..,ii P, ; r
r . rq „F'3..e +T l "r ;., a �y ra 5- c:y xK ¢�r.;c x x
o s 134'1 ,4** .,•. s v"": 4, ', 4i ,ms s
0
5'000"
CI
All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal.
Design Results Actual 0 Location Allowed Result LDF wad:Combination(Pattern) System:Wall
Member Reaction(lbs) 2117 @ 0 3281(1.50") Passed(65%) -- 1.0 D+1.0 Lr(All Spans) Member Type:Header
Shear(lbs) 1529 @ 8.75" 3806 Passed(40%) 1.25 1.0 D+1.0 Lr(All Spans) Building Use:Residential
Moment(Ft-lbs) 2778 @ 2'7.50" 3737 Passed(74%) 1.25 1.0 D+1.0 Lr(All Spans) Building Code:IBC
Live Load Defl.(in) 0.048 @ 2'7.50" 0.175 Passed(L/999+) -- 1.0 D+1.0 Lr(All Spans) Design Methodology:ASD
Total Load Defl.(in) 0.078 @ 2'7.50" 0.262 Passed(L/813) -- 1.0 D+1.0 Lr(All Spans)
•Deflection criteria:LL(1/360)and 11.(1/240).
•Bracing(Lu):All compression edges(top and bottom)must be braced at 5'3.00"o/c unless detailed otherwise.Proper attachment and positioning of lateral
bracing is required to achieve member stability.
•Applicable calculations are based on NDS.
Bearing Length Loads to Supports(lbs)
Supports Total Available Required Dead Roof
Total Accessories
live
1-Trimmer-DF 1.50" 1.50" 1.50" 804 1312 2116 None
2-Trimmer-DF 1.50" 1.50" 1.50" 804 1312 2116 None
Tributary Dead Roof live
Loads Location Width (0.90) (non-saw:1.25) Comments
1-Uniform(PSF) 0 to 5'3.00" 20'0.00" 15.0 25.0 Residential-Living
Areas /�
Weyerhaeuser Notes 0 SUSTAINABLE FORESTRY INITIATIVE
Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Y
Weyerhaeuser expressly disclaims any other warranties related to the software.Refer to current Weyerhaeuser literature for installation details.
(www.woodbywy.com)Accessories(Rim Board,Bloddng Panels and Squash Blocks)are not designed by this software.Use of this software is not intended to
circumvent the need for a design professional as determined by the authority having juristic ion.The designer of record,builder or framer is responsible to
assure that this calculation is compatible with the overall project.Products manufactured at Weyerhaeuser facilities are third-party certified to sustainable
forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC ES under technical reports ESR-1153 and ESR-1387 and/or tested in
accordance with applicable ASTM standards. For current code evaluation reports refer to htip://www.woodbywy.wm/services/s_CodeReports.aspx.
The product application,input design loads,dimensions and support information have been provided by Forte Software Operator
Forte Software Operator Job Notes 10/6/2016 9:06:53 AM
" Ryan Zink Forte v5.0, Design Engine:V6.4.0.40
Zink Design Services.LLC
(503)701-8213
zink0l @yahoo corn
Page 1 of 1