Loading...
Report (43) Simplex TrueAlert® Multi-Candela Notification Appliances UL, ULC, CSFM Listed; PP FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC)Acceptance* Non-Addressable, SmartSyncTM Operation Compatible RECEIVE ,k „ „, Features Visible only(V/O)24 VDC notification app ' with high output xenon strobe, available fdafl 6 2016 ��' or ceiling mount: 41 CITY OF TIGAR p- • UL listed to Standard 1971 ` • Intensity is selectable as 15,30,75,or l (VJIRINGt ! visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements(refer �� to important installation information on a e p g ) l � 1 3 • Polarized input allows connection to compatible reverse polarity,supervised notification appliance circuit(NAC) Wall Mount Strobes • Regulated circuit design ensures consistent flash output and provides controlled inrush current,Utr&N'24.1 FIRE • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: • 4006,4008,4010,and 4100U Series fire alarm control panels with NACs selected to provide strobe Ceiling Mount Strobes synchronization or SmartSync two-wire control** Descri•tion • 4009 IDNetTM NAC Extenders • Separate strobe Synchronization Modules that are Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical available for Class B or Class A operation boxes.The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity provide Class B or Class A output from conventional NAC inputs output,on-site model inventory is minimized and changes Strobe housings provides flexible, easy, and encountered during construction can be easily accommodated. convenient semi-flush or surface wall mounting: • Rear of housing does not extend into box Wall mount strobe housings are a one-piece assembly (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box.The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang • Wiring terminals are accessible from the front of the electrical boxes. Color choice is determined by model number. housing providing easy access for installation, inspection,and testing Strobe Intensit Selection • Covers are available separately to convert housingcolor During installation,a selection plug at the back of the housing determines the desired strobe intensity.An Optional adapters and wire guards: • Wall mount strobe adapters are available to cover attached flag with black letters on a highly visible yellow bacsurface mounted electrical boxes and to adapt to side of the strobe alllens.the selected intensity to be seen at the Simplex®2975-9145 boxes p side of the • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes Proper selection of visible notification is dependent on occupancy,location,local codes,and proper applications This product has been approved by the California State Fire Marshal(CSFM)pursuant to of: the National Fire Alarm Code(NFPA 72),ANSI A117.1;the appropriate model building code:BOLA, Section 13144.1 of the California Health and Safety Code,See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in ICBO,or SBCCI;and the application guidelines of the this document.Itis subject to re-examination,revision,and possible cancellation,Refer to page 2 for listing status of wire guards.Additional listings may be applicable;contact your Americans with Disabilities Act(ADA). local Simplex product supplier for the latest status.Listings and approvals under Simplex ** Simplex multi-candela SmartSync two-wire horn/strobe appliance operation is protected Time Recorder Co.are the property of Tyco Safety Products Westminster. under one or more of the following U.S.Patent Numbers:5,559,492;5,622,427;5,865,527; 5,886,620;6,281,789;6,954,137;7,005,971;and 7,006,003. S4906-0001-3 5/2008 Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their Class B SmartSync two-wire control is available reflections can be seen from one location,synchronized from: flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of • 4006,4008,4100U,and 4010 Fire Alarm Control Panels(refer to individual product data sheets for more random flashing.These multi candela strobes are synchronized over a two-wire circuit when connected to information) compatible NACs,to compatible Synchronized Flash • 4009 IDNet NAC Extender(refer to data sheet Modules,or to SmartSyne Control Modules. 54009-0002) • SmartSync Control Module(SCM)4905-9938(refer to SmartSync Two-Wire Control data sheet S4905-0003) Some applications desire the audible notification Class A SmartSync two-wire control is available appliances to be capable of being silenced before the from 4100U NACs and from the 4905-9938 SCM. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the Additional SmartSync compatible notification alarm condition is reset(on-until-reset).SmartSync appliances include separate horns and combination operation mode provides this function using a single horn/strobe notification appliances. circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances(Strobes) Model Mounting Housing Color 'FIRE"Lettering Description 4906-9101 Red White 4906-9103 Wall White Red Multi-candela strobe with intensity selectable as: 4906-9102 Red White 15,30,75,or 110 candela;synchronized flash rate; Red SmartSync two-wire control compatible 4906-9104 Ceiling White Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm) 5-318"H x 5-114"W x 1-5/8"D 4905-9940 White deep surface mounted boxes ( mm x 133 mm x 41 mm) Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit,may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Surface Mount Adapter Plate;zincplated;required for mountingto Dimensions 4905-9910Q 4-7/8"x 3-1/8"x 0.060"D handy box;not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with in/out 18 AWG(0.82 mm2)wire leads,rated for 2 A NAC, 1-3/8"x 2-7/16"x 13/16" 4905-9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output;mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description 4905-9992 Red cover with white"FIRE"lettering Dimensions 4905-9993 White cover with red"FIRE"lettering For Wall mount strobes 5-1/8"H x 5"W x 1-1/2"D (130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) 4905-9926* Ceiling mount semi flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8"deep (156 mm x 111 mm x 73 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0001-3 5/2008 d Strobe S•ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 VDC;see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd' Mount Strobe Setting(see Note 2 below) 60 mA 110 cd 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 63 mA 124 mA at other voltages 24 VDC 40 mA 164 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 Cd'' 30 cd 75 cd Mount Strobe Setting(see Note 2 below) 75 mA 110 Cd 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA at other voltages; 24 VDC 50 mA 21'mA 83 mA 155 mA 211'mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired,changes effective May 1,2004.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting Mounting is compatible with ir, lror ) o o\single gang,double gang,and ) �l 4"(102 mm)square boxes, _ = _ / i ' 1-1/2"(38 mm)deep,by others �.[o1 ) /° 7 °( ti / o � � �� IMPORTANT!WALL MOUNT ( _ , \:� (Liqq INSTALLATION HEIGHT REFERENCE // 1lJ' I� BottomoflensOOQUte ( iseitherevenWiring access hole7. iO �. % with,orslightlyElectrical® � 1,44,1\ �, ` above bottom I box outline �• / of compatibleII Wiring terminals 46 thhli W.J. boxes Imo" iei Mounting Holes: �.a�� O z ,: 4"square(4) .0.11161 NFPA 72 requires 80"(2.03 m) Single gang(2) that the entire lens minimum 01111°, Double gang(3) be not less than _f_i_ 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only - from rear of housing; Lis I • factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-3 5/2008 r Ceiling Mount Strobe Installation Reference / Handy box,1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others /' Also can be attached to boxes /`r"" /,./ mounted to drop ceiling T-bar with (l ( 1 ( 1 clips(ERICO No.512 or equal) �/ �J / 4905-9910 Adapter Plate,required for ,,, os, (using surface mount with handy box unless the 4905-9926 wire guard I" ' i -I Ceiling mount strobe oh l IF -5) E i �. I Optional 4905-9926 wire guard l _ :111.i, with mounting plate !. ,__ i ....... ,,,,,:ji, ' Strobe intensity VA ki k 01 tAllihk viewing slot l'tp,_ 11. itilire an t Intensity selection plug, vitOW accessible only from rear of lens i housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapterier Skirt --n and Optional Wire Guard -.. Surface mount conduit and f 0 box shown for reference Ilii1I '���� __ 4"(102 mm)square 6.1-I-I-I�1I *�..�` ®°°M` box profile,1-1/2" f� -`•- iII.IILI�I�Il i II (38 mm)deep . ___1.I_���11 0 O I Optional 4905-9961 __upI ' Wire Guard r'' 14 FORE 7 Strobe -`- [7.0mi _ -� 4905= 931 Adapter Plate O t Optional Surface Mount Adapter Skirt, 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; 4905-9931 Adapter Plate (shown here for reference only, 4905-9940,White(conduit knockouts can be used on other mounting options) are provided on all four sides) Tyco is a registered trademark of Tco International Services GMBII and is used under license.Simplex,the Simplex logo,IDNet,TrueAlert,and SmartSync are trademarks of Tyco International Ltd.and its affiliates and are used under license.NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NFPA). El Simplex Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4906-0001-3 5/2008 www.tycosafetyproducts-usa-wm.corn 3 2008 Tiro Safety Produces Westminster.A/l rights reserved.Allspecifications and other information shown were current as tfdocn m ent revision date and are subject to change without notice