Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (38)
a Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND B BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). %M. o Delete Line 0 XXX-XX GREEN LINES=INTERLEVEL_CONNECTIONS/SUPPLY y u BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. Q o 1 } MAXIMUM SPACING(TYP) = 1/2"PIPE SIZE > o Add Line SPRINKLER MODEL(TYP) x a , HEAD SYMBOL(TYP) CITY OF TIGARD r.� =3/4"PIPE SIZE d m=au-, Add Tee t = 1"PIPE SIZE O a°'w L ',7'.C,7,2 7 Approved.................... 11, —'— = 1-1/4"PIPE SIZE 'aLLwo Add Elbow Ap ............ [, vzay prOVed. , `"ondi��tionall W�,��Add Coupling eeLederto:Follow................. = tiia rnoAttached......• ---/-�••• 21 �4,2am Add Head A 1Al2A'3 �-r n fit` "'��� ci WO,°n'F-WPermitNumber: Jaz_ Delete Head AddreS$' II . �''. L1 •Y � m o- By: f l..l Date: � � a==,r Move Head �- -�- o o ac" 1 • Ut .0oc<,�„3.7m 0 Note:All revisions must be reviewed by Uponor ,i�_! F,. ¢= . o Table F002-1 ?_,"r-6.,:1,-,,,,-_ z PtZ Multipurpose Fire Safety Systems oo�Y aQ-c z o The Uponor Residential Fire Safety System is a residential fire protections - r.-..5 n.° °a system installed in combination with the cold side of the domestic potable L R a-a-g o Y a a K.-- u., water system. Only licensed contractors trained by Uponor can install this ..F„,>, 5¢ ° 1 system. Q aEozz'poz o,>d 1"AQUAPEX INTERLEVEL J�zus�J:�da,�4:ii What to do if Changes are Required CONNECTIONS FROM FIRST U a<LL n a w N-'7 1"AQUAPFX INTERLEVEL in z 2 0 5 u z 5 If any features or obstructions require the addition or deletion of sprinklerFLOOR TO SECOND FLOOR in o s=E z - CONNECTIONS FROM SECOND m a d w heads,or significant relocation of sprinkler heads,contact the Uponor Design p z s x a V z c C FLOOR TO THIRD FLOOR r o = - 6 Department to determine if observed changes require a redesign /� 1 • ? x w c s = �, (888.594.7726). / /l A V\\ - p I'o ,,p a o 7-pz d J MOST HYDRAULICALLY REMOTE HEADS /// 1 \ / 1 \ \ \ ;4,.:::.: ao0 ¢.wHEAD# GPM PRESSURE REQ'D AT STREET rt � � �- L. / �� ° pc�zoc�z d2 HEAD H.12&H.8 26.0431 51.84 % `\ \ � I \ o c z< a 1 HEAD H.10 17 49.9 1 1 N "�,Ya .E.K.`a S \V A yl I / 2 1st 4 2nd Floor Jl( 6 3rd Floor ' 1 \ \ — / I 1 \ - '' 1 v - I LF SENJU SPRINKLER Model RC-RES Flat Concealed PendentQuick Response �� RC-RES-16 N\,k 12 TOTAL $(,RE5 18 1�� �' , r p H.1 �- - \ H 2 -- {1 ��� 0 - - 2 K=4.9,162F°,7/16"Orifice,Maximum Spacing 18'x18' ,, \ _ _ OFFICE �j RC-RES-18 Sprinkler head demand: 17 gpm @ 12 / � 11 �� � �,\ �L' COPY �S` ?l1 \ Garage L r j LF SENJU SPRINKLER Model RC-RES Rat Concealed Pendent Quick Response • 1 = T1 °.r3 VA \ �( 91.17 � _ 1 Y"AquaPEX TO SYSTEM ® 8 K=4.9, 162E°,7/16' Orifice, Maximum Spacing 16'x16' �� t1 1 T T 19_ RC-RES-16 Sprinkler head demand: 13 gpm @ 7.04 I/ �, il I �\ • I1,.E - / ;c VMAIN SHUTOFF OFF - - K�4.9,J175F°I7/6 SPRINKLER Orifice, Maximum Spacing 12'x12 Pendent Quick Response s 1 /�11 I i� M.21 I � i ,-33,-'3,4 l VALVE LOCATION 0 - 2 P 9 J ' F 8 T 2 �� � T.1�4 I 1111 1 \ t ,1 ! I Sprinkler head demand: 13 gpm @ 7.04 RC-RES-12-175 p RC RE 6 1 �� F.5 , 1 I'll �� � t2 r 11 I - _� 25 1.24 v _F� aRE$ 21F7 z f I M Bath' .rt r.., .„„ ' - ‘'I.':... ti I I R . f - -` 3 T � 41 T,39 34t y � , a s =a LL T.35 T. EXTERIOR WALL d, ELEV=109' p / � .6t 37f�=aow ep / 1' A uaPEx I' '-�-- - I. L1/4_,„N STATIC: 67 siFLOWRAL: 36501 sm / \ H1(] H1 RI} (� 000��xmuLu u u a o m o0RC-R 8 �, F1I Y� 1.:11 1I. Ce N 3 / � q1 _ �1 _ c�€sh6 L: TO HOT WATER HEATER I II 1 �' 1 I �� w TO SYSTEM i I I Fid. .11 CI ELEV=104' VA N." ! _(r- _L�1FULLPORT w in dL r. BALL VALVE ��1 ,�, �'"iii .c:8 LI -J ® ® �(7PSRL055 FLOWING 26GPM) �I �� c �I �-- -- w r y / ® Y'APOLLO 36E PRV F 1/ ✓1 =z ORE EQUIVALENT -' ELEV-100' ELEV=100' / ''` /i ' 1-'"'� L I—I =m o z o ////////////J D H o .a o 1"METER 3- THIRD FLOOR 2 SECOND FLOOR FIRST FLOOR aou �� F 35'OF 50'OF SHEET DESCRIPTION > 1"COPPER-K 1-1/4"AquaPEX F1001 F100 F100 ALL LEVELS 1/4" = 1 -0n 1/4" = 11-0n 1/4" = 1'-0" 4 WATER SERVICE DETAIL 5 D 5 15 SHEET NUMBER F100. NTS F100 i © UPONOR - CONFIDENTIAL I. Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations N AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural Pr0PEX LF Brass Fireto cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements m should follow the guidelines of the insulation manufacturer. See Uponor z SECTION 3.3.11.3. Required. �` - _ Push-on Sprinkler Adapter Documenttio"Uponor AquaSAFE Attic Insulation Guidlines"ts for attic ` p 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON BlockingMaybe Tee - j h-on Nut installation guidelines(Provided in Contractors Documents package or online r `-' 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Use The2 To Adapter Fire 11/q"Min. at www.Uponorpro.com). Sprinklerj/� Blockingis Used, ' o i I a. THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND / i 11/2"Max. > p Screw Holes. 1 I LPlanter Boz Window,ea Window or Similar Feature. 'i' UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. �� C -'Bottom of Mounting Extreme Temperature Installations Y a S"o Bracket to Face of Truss AquaSAFE Residential Fire Safety systems are often installed in attics or If no addihnal floor area is created No Additional Sprinkler is Required. a m w u 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter- - -'/ other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less O ry u'' RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket i L_9// the recommended extreme weather installation instructions to isolate and / '"o,> PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE \�I t w v a w SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-16 v t oz system also delivers domestic cold water directly to plumbing fixtures, 0 N\ O SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1 1/2" 9'-0"or less i' ry a -�- } Uponor highly recommends that you protect the tubing with adequate / w0. :ii^t7 Full Course i insulation in warm weather areas to minimize heating 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH M1-f IT-,-I E-I' of the cold water \ o to w Thread S{mews u UJ/ U 3 NFPA 13D 2016 EDITION. In Bottom'Holes supply. ' v o o+a 3 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. _\- \ Installation methods include,but are not limited to: ` / W a A a umi • Tenting over the fire sprinkler piping. Ino\ t �\ cav+H w>+ 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free Flat-� be- DAMAGED MUST BE REPLACED. Concealec Senju \ •'t° • Additional layers batt-in insula additionalofloor area is created.Cannot exceed fi , more he 2'-0" Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the '8, Sprinkler Head < '.- 7. _ < Cover Plate sprinkler.No Additional Sprinkler is Required. w �- z c _. 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. o n z -z t o' Caution: If you will be installing spray foam insulation,make sure to x,x> - ¢�?z_p h x7o =a- 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foam ,`;'`F„,.2 ,82.-V,F o x li ti manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From _o, ,z <o- 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources ;; x`a o` r c WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance y n M,x z z z c o:o PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR with local building codes. - .,A z o? .0 ProPEX LO Brass Fire < N F z o 3 AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH Al WATER SOFTENERS, Fire Sprinkler Adapter Ordinary Intermediate =_ > z- Sprinkler Adapter Tee Heat Source Tem Tem O o z o z-'-°- FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM -, PushonNut P P• ;o¢�>p - 335°-170° 175°-225° x'--u"='-z THIS WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE _- Bending PEX Tubing §:e2'c`c a` o=- Side of Fireplace 36" 12" ,;=',E z�.;z u 1K.Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" m r < 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. ---_�- r-. 1%2'Max. the outside diameter(6 x OD). P W❑ o.r o=2 z z a 3 0`, Fire Sprin der Adapter - • Bottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" E- -z¢z_,2?S , >o P Q w s-o =x,27'5-r 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket Bracket to=ace of Truss tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" Q?_U p5525 x 2 0 3 O\_\\__i ® Wall Oven 18" 9" U, <,,-ma y&i?a 5< 12. MINIMUM SPACING BETWEEN SPRINKLERS 11 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2" Recommended TubingLength Between Fittings 0 z' F o�>c S u z y ala BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Course �- g 9 Hot Air Flues 18" 9" N L¢d o z E U z ci"'-`.0 RESTRICTIVE SPACING LIMITATIONS. Thread Screws I f i } Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" O?r'H o z= r °z i i C� ¢L.z r'F;,i o" In Top Holes CJ 3/8"ProPEX Fitting 2„ Uninsulated Hot Water Pipes 12" 6" _ - o-'x o o Q 0 u;o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING z 3 r z 0 i, MOUNTED OBSTRUCTIONS. _ t 1/2"Pr0PEX Fitting 2 1/2" Side of Hot Air Diffuser 24" 12" ,<N a c o. ; c • Front of Hot Air Diffuser 36" 18" 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE -�! 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3" g,=0..,,,� 5.z y Lead-Free Flat _p �'C p SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. -';- rn Concealed Sen u \ 1"ProPEX Fitting 4 1/2" Furnace 6" 3" >u z r u i<>z >o J Concealed Flat ou+zoo"Eouz<F- Sprinkler Head Cover Plate 1 1/4"ProPEX Fitting SOW-250W Light Fixture 6" 3" "'.c c a'u m z --c 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN 9 5 1/2" 9 _ >o o_,. ->;=o_ CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS 250W-499W Light fixture 12" 6" 'y x:3„r y z y ?`) a THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. w>-a`^ -^ t'i ojoy,sa 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERS Exposed Installation Requirements. - - • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG Al Uponor Ain s ar r"tubing(white)and ProPEXTM EP Fittings and 11 o Ing \ I m THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FT'PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: - - (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. o � r, /�a VIIADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open U m ^� (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 Fc(1.7 M') 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ I \ Q THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED S. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center 'I 1.55" / 1.66" ALONG THE FINISHED FLOOR. are used. 4' (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation In 3,, Hanger1° Han er PLANE OF THE PRIMARY WALL. temperature rating of 155°F(68°C). 2 4 9 (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. Tubing Support Spacing: E (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal tubing supports designed for plastic tubing shall be used. (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE 2. Do not use supports that will damage the tubing.Inspect metal Enough to Allow the Tubing to Expand and Contract) supports for sharp edges. g Supports Every 32",if Horizontal Runs are 17. NFPA 13D 8.3 LOCATION OF SPRINKLERS. 1. Along Horizontal Runs,Install • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPE en tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. enough tubing for freedom of movement to expand and contract. Along Supports Every Four to Five Feet,at Each THROUGH 8.3.8. 2. Vertical Runs,Install o • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 M')AND LESS Floor and at a Mid-story Guide. O A- • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT 2 o MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test E 5 (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT°(2.2 M'). The In-line Flow Test can be constructed on site. It performs a Flow test to 5 xi in o (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE High Upstream Pressure a o'A _ g tr ensure proper system operation and flow(see Figure F003-8). o MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. u F o� E If the upstream pressure exceeds 80 psi a pressure reducing valve may z w '" • 8.3.4' SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND a ii need to be installed. Some jurisdictions may require a pressure reducing m `O SIMILAR STRUCTURES ri a°,y'v • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE valve regardless of upstream pressure. / j Uponor AquaPEX a F m.. -- EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND Tubing o CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, LLI / w CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING % f PURPOSES. • z w • 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR • U o Ctj a O 8.3. .1.2. _ ` i- '.- u • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING % GI M a¢Q z a w :''-',,,°1 UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. j ` g z z a u 5 • 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE (V O O a J o.in m w DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Male Threaded Coupling Pro PEX Fire (NI u u ¢a 2 3 m INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Sprinkler Adapter Le-'-'-' EQUIPMENT FROM THE OCCUPIED SPACE �� cc N w • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT -To Hot Water Heater Male Threaded Coupling - 1"Ball Valve LLI CI) L ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. -- -. ."\ • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING F/' Female Threaded Q �/ o E CONDITIONS: LI' 'e Tee with Water LL G A 3 (1)THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Pressure Gauge O n o 0 Pressure Gauge Sprinkler Orifice - (Optional) -2-, 100 FT.(2.83 M'). L to - d. .II ,,^^ oo w (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS c Ce W `oil a ry ci 'O AT THE LOWER CEILING ELEVATION. Y ..m'in o Main Fire Sprinkler Flow Test 1 1 ( I A Q A w (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE - Shut-off Valve To ensure the system provides enough water for proper fire sprinkler • • • °'w f m 1". TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. ul _ o a, performance,you should conduct a flow verification test. (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 M')SHALL BE PERMITTED TO HAVE A PLASTIC COVER. 5 • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS - li Uponor Warning Signs > Q w m £w r (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR _ o Note: The NFPA 13D Installation Standard does not require flow I � (1"I 5 m z verification. Z o o 'W` o T. ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED -' L PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. a Pressure Reducing Before performing a flow verification test,confirm the water pressures by Ce n r G 3 w 5 m 5 72, • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING - " Valve 7P-` a i p E 6 p z contactingvilabethe Water and hr Department of your hl city. Ensure the. o o u z EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. available water pressure matches the pressure used in the system design. F 18. INSULATION GUIDE LINES PER NFPA 13D. Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40°F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS > USED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40°F,INCLUDING AREAS PROPERLY .7( your local code. INSULATED TO MAINTAIN 40°F. •• A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. at CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in at PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40°F WILL BE MAINTAINED. 1 Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and iii Troubleshooting. If there are any questions please contact Uponor. = 80 psi © UPONOR - CONFIDENTIAL FO 0 1 HPRV Set Pressure ti