Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (21)
a Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND %�O XXX-XX BLUE LINES= FEED TO FIXTURES(BATH,SHOWER,ETC.). f o Delete Line O GREEN LINES=INTERLEVEL CCNNECTIONSiSUPPLY. w MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. o Add Line — -- SPRINKLER MODEL(TYP) ��� = 1/2"PIPE SIZE > CITY OF TIGARD �'— =3/4"PIPE SIZEFii o HEAD SYMBOL(TYP) v = 1"PIPE SIZE N°u Add Tee Approved [� 0 = = 1-1/4"PIPE SIZE W 3LLso L Conditionally Approvedv =o Add Elbow ( i _ y, r , ^f See Letter to:Follow t 1 ,, • _ w Add Coupling Attached ,y. l..I.� ,. .h-Y i w P'n o '1r'°JQw O Permit Number: msrAo tt,-no�3 L a 0 w B Add Head Delete Head - Address: urk r)CA 5.(.ti. Si l*d- i .-Z(1^0./....4.- `� `' ,-,-.,.0 a w c2 W (0 set Date: IC''- -ac1(� 5> z� = = Move Head p >0 <o '��3 ,�- ��- s z_ - o z 000w-a z zj d ,d ,amu OU�z 6 Note:All revisions must be reviewed by Uponor 1"AQUAPEX INTERLEVEL qq- -L';''..:`,:-': w o`� --'-,,au,,-,.,... .. z: Y Q 1"AQUAPEX INTERLEVEL '',•;!1!'''',...,.,'....''1P.''',_5 w ¢=' F p CONNECTIONS FROM SECOND CONNECTIONS FROM FIRST ' z o S u'� <u Table F002-1 FLOOR TO THIRD FLOOR ''`=2"6\8"..,-.-= z z-L=.2.,54 N r FLOOR TO SECOND FLOOR :5 �Fz Multipurpose Fire Safety Systems4 t oo< >o z The Uponor Residential Fire Safety System is a residential fire protections ` 4 S.1 MAIN SHUTOFF -550¢ ¢`�° ¢ system installed in combination with the cold ode of the domestic potable /// \\ VALVE LOCATION qSYSTEM o 4 0 x• j 1 A uaPEX TO S :r_ What towater ntem. Only do if Chanl'censed es are Required contractors trained by Uponor can install this - / _ -----_ -l' * \ \— - -_ _- f E Q R'o< ,z d F ¢°3.e system. )- ` -- heads,f�a rfeatures significant of srinkler heads,dion or deletion of sprinkler C-'-± i ---- _, _ ly fi U a C ¢ LL < If Yrequire P contact the Uponor Design RC.RES-16 - 1,';^,.i, .,,'., �., �, ��l / Q - o azo a> F--,i 0 z ,4o >oo Department to determine if observed changes require a redesign / _ w (888.594.7726). �. 1 / � V I �� Ct • < o -. zyo >o z�� RC 15 I \ K`= o � < MOST HYDRAULICALLY REMOTE HEADS 1 \ I 7 i6x 1 o HEAD# GPM PRESSURE REQ'D AT STREET0 1 HEAD H.13 13 38.25 , `� / /,, �� , ,�. _ I �, Ft w> � ' � "" ,I -- L' , \ F J r -- �� ~ opo a 2 HEAD H.2&H.1 26.0715 61.42 a � �> 3: c N �a �� IIB v � say°zao < _� J RC-RES-16 / f p Co 1st Floor 1 .4 T. _ �I� T � ;fi= � 12 2nd n°° '�, �' ' ' _ .21 T.17 v _ _� �rl 1 3rd Floor �'� `, �QI q ` 5. T'20 T f i, Q` ' 14 TOTAL LIIlen...rf � �- s }�-_ ' L I,i20 \ \ �� �� �' T16 LF SENJU SPRINKLER Model RC-RES Flat Concealed Pendent Quick Response " ;, 5 = !ik 7 L R - / i � L \ ® - - - 14 K=4.9, 162E°,7/16"Orifice, Maximum Spacing 16'x16' p L ,,,,IRC-R- -1 ,j_,,.-- 1 �7C \I 25 °, `' I ` r OFFICE RC-RES-16 Sprinkler head demand: 13 Bpm @ 7.04 fi6 R�-RE$-1 24 NiNig /68 �ICOPY fif` �. 5 �Cenl _- 11, � ���� Garjge E. r - a SEs 16 }ryFl T.27 ' T. 9 T.28 L7,-,. --. "' y "�� i 5 o f L x.10 `� � _ 1= j 1 - v-� T ' ) r �v Bathl-, 7" �� 1 -' 5)% IA .—4 : CD ' _ 0 11 -- _ ARES-16 ,_____,__F74! E E ��''`' 3' 30 -4- - I�1 Entry \ ~ 11 " 'Q E T. w o w w fC.RES 16 1 ;RIES 16 H.13 <w� oI I EXTERIOR WALL T T2Ch PWdr. y E))h.1Eam. r 'I 4 l ' ` £ L...4 O RC-RES-16 I v ELEV-109' • ,' r u a � F26,i,Qu 0 STATIC: 67psi 5�F7 a <a w pl Bedroom 2 �� _ RESIDUAL: 51psi 1 A uaPEX a M � --- 11 -� I� --�'--- ' e _ o u u a a�n z❑ 9P �_ �$ , porch (� o00��imw S FLOW RATE: 3650 m o \ w TO HOT WATER HEATER _ TO SYSTEM / O o - A 0 C °a / ELEV=104' H. u 3 THIRD_ FLOOR 2 SECOND FLOOR FIRST FLOOR '---..0so t aw 1"FULL PORT lO BALL VALVE __-- I \ z > ° rya II = _ I II F100 11 I 1) F100 II I II LIJ LJJ M a / ���1"APOLLO 36E PRV F100 i/^ i O i ^ O a w u 1 `F 1 - 1/`F = 1/4 = 11-0 > H_ Q -w•ww w OR EQUIVALENT - (7PSI LOSS FLOWING 26GPM) H1 z m o p g LL o ELEV.-100' ELEV=100' j m G i .///////////A F w H G 3 W n c a 1"METER 2KSwI o a D U V Co .17 35'OF 50'OF SHEET DESCRIPTION v 1"COPPER-K 1-1/4"AquaPEX ALL LEVELS E 4 WATER SERVICE DETAIL 5 D 5 15 SHEET NUMBER F100 NTS - w 1/4"=1'_0" m , F- © UPONOR - CONFIDENTIAL F100 • Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations N AquaSAFETM GENERAL NOTES: In areas subject to freezing,care should be taken In unheated attic spaces See General Notes 8.2.5.7 for Architectural ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements `o, Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor ` z 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM BlockingMaybe Fire Sprinkler Adapter SECTION 3.3.11.3. Y ___ __ _ Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic ` f of Push-on Nut Required.If installation guidelines(Provided in Contractors Documents package or online ,L1- u Blockingis Used, > . • i at www.Uponor ro.comtt 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON --- 1/a"Min. V ) I 1 a p Use The 2 To a THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY P „ INFORMATION OF UPONOR COMPANY AND i/ Max. ''^ Screw Holes. ) ( BoOom of Mountln Planter Box Window,Ba Window or Similar Feature. w f UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. �� C g Extreme Temperature Installations Y ----.- Bracket to Face of Truss If no atldi[inal floor area is created No Additional Sprinkler is Required. ^@� AquaSAFE Residential Fire Safety systems are often installed in attics or 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE - a m,7,,,.;,E¢ Fire Sprinkler Ada i ter I other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less t'[,‘,',- `' N u RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket 1 the recommended extreme weather installation instructions to isolate and / PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE '�_J w 3 a.w o SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE protect system components from extreme temperatures. Because this RC-RES-76 O SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. �� system also delivers domestic cold water directly to plumbing fixtures, ® \ .�,°' ^ 3-#10 z]1/2" 9'-0"or less )v z O E •-}- Uponor highly recommends that you protect the tubing with adequate / y.�'^'c7 ✓ m^ Full Course I 5, 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH eN5 1-f ti insulation in warm weather areas to minimize heating of the cold water \ N s w 3 NFPA 13D 2016 EDITION. In Bottom Holes LJ CJ supply. `i' Q z Q m0 M Thread Str 5. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. \ -_�__ \ Installation methods include,but are not limited to: w ry m R w Tenting over the fire sprinkler piping. ` o\ I / w\ 0 Fn'i-.w 3 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR Lead-Free Flat - • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 fte,be more than 2'-0" DAMAGED MUST BE REPLACED. Concealed Senju Concealed Flat • Increased depth of blown-in insulation. deep,more than 9'-0"wide and be with in the coverage area of the 0 u Sprinkler Head Cover Plate • a ---."!,4 sprinkler.No Additional Sprinkler is Required. .s:± o m x o 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Y z Caution: If you will be installing spray foam insulation,make sure to A.E. � �o protect all components duringapplication.Consult with the spray foam E5-R.6;. 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction p PP p y C c �2 o - - manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From u i a s>z F c i,3 p cam, 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources u ,t=0-o w-°ft y o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND Consultation with local building officials is encouraged to ensure compliance o z i y s°o PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX LF Brass Fire with local building codes. F o¢o`m o?u z z'ft c AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Fire Sprinkler Adapter OrdinaryIntermediate z�,h u 0 3 i K Sprinkler Adapter Tee pHeat Source Tem ° O x S z,-=__z FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM 1 i Push-on Nut p. Temp. z z x.= 135°-170° 175°-225° 0oa°r_rfu WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE z u o z o o THIS SIGN". pp Bending PEX Tubing Side of Fireplace 36" 2" o o°°i s z°a s O / 11/a'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times p 0'y L c o "o r a i z TO BE UPONOR"AquaPEX®"UNLESS NOTED. i ( ) Front of Fireplace 60" 36" E o o m N o P,2 i<2-o 10. ALL INTERIOR PIPING .r�� 1/ Max. the outside diameter 6 x OD). Fire Sprin der Adapter - - 0ottom cf Mounting Bend supports are available for 3/8",1/2",3/4"and 1"Uponor AquaPEX Wood Burning Stove 42" 12" N o o a d t h 5 m z°u 11. UPONOR"A uaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURERS RECOMMENDATIONS. Mounting Bracket Bracket to=ace of Truss a F=z z o s r_ >3 u: q9 J tubing to facilitate 90-degree rigid bends. Kitchen Range 18" 9" J y z a o_= ¢ c y p Wall Oven 18" 9" rz� 1,,-`~ 12. MINIMUM SPACING BETWEEN SPRINKLERS I5 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x 1 1/2" V ® V a< ¢` < BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Recommended Tubing Length Between Fittings Hot Air Flues 18" 9" V`'o u z z° z Y RESTRICTIVE SPACING LIMITATIONS. Thread Course F w u¢woo <c c,_<v' S<rews I I Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" D m y 2 z= n z.i u,u ?VFN In Top Holes t_7 3/8"ProPEX Fitting 2�� Uninsulated Hot Water Pipes 12" 2 o F=