Plans (4) Markup Legend SPRINKLER SYMBOL DEFINITION COLOR/LINETYPE LEGEND II BLUE LINES=FEED TO FIXTURES(BATH,SHOWER,ETC.). o Delete Line ` O XXX XX GREEN Li.,HHS=INTERLEVEL CONNECTIONS/SUPPLY. J u I} f MAXIMUM SPACING(TYP) BLACK LINES=SPRINKLER HEAD TO SPRINKLER HEAD. ® o Add Line SPRINKLER MODEL(TYP) /^''��l bQ'n� ✓� = 1/2"PIPE SIZE >M o HS HEAD SYMBOL(TYP) arY O��V�W / o� =3/4"PIPE SIZE a '�,° Add Tee {/�j( = 1"PIPE SIZE 0 N ; L Conditionally = 1-1/4PIPE SIZE W 3 a w o Add Elbow Approved..............I I " Q j v r z a See Letter tat Follow.».»...«.......I I N 3 Add Coupling I W AttaChCeTd•••••...»••••••t I 1 ' 3 Add Head -�.1`-- 2`--E.3\ mS\4201 -00 I S A � 4+a ',r.t ,, ice. c°v,'H w l S.W.5 kd FoK ferrate C 4 Delete Head -(X)- ,���� l'�4'5'1r\ Date: 4" , V P 1 ___ J �,, VII-‘- E 2016 °� ���g� F�F Move Head -O- -O- ° y m 1 1 1'' 3 000. ° ,-,1 8 1 `i=*1 d 7 f T d!.. w�°gyLi' tm Wiz_ smo Note:All revisions must be reviewed by Uponor YY o ° Table FOO2-1 4fgg F EAwg-IG ,„.. 1.:1.„i“:, ,,,1-y; .% ='000�; �-, i .� .1J z. Yi a da z..,ao L7- Multipurpose Fire Safety SystemszEo�ma; ^o The Uponor Residential Fire Safety System is a residential fire protections d o o°o o a a°3 =F system installed in combination with the cold side of the domestic potable m"°¢o¢5 o 5>¢a z water system. Only licensed contractors trained by Uponor can install this 1"AQUAPEX INTERLEVEL W°o om Sv o, i z¢>p system. CONNECTIONS FROM 1"AQUAPEX INTERLEVEL 1-i z¢o i z-„="Z,',.,E¢o�,,; BASEMENT TO FIRST FLOOR CONNECTIONS FROM g°¢'z,,°oo EzEo What to do if Changes are Required ^^ BASEMENT TO FIRST FLOOR V z z- N w f,w w h 5°• 4 /I S.1 MAIN SHUTOFF ¢w w 0 e, 0- t, - If1"AquaPEX TO SYSTEM fA w�Ca °N�>� If any features or obstructions require the addition or deletion of sprinkler N \ VALVE LOCATION H w¢N z z _ v,_ heads,or significant relocation of sprinkler heads,contact the Uponor Design / \ \ D m a o 5¢¢o z°i u �wozr-uz1 5855 Department to determine if observed changes require a redesign / / N / I \ x F-x y o°a (888.594.7726). / \ _ - - i -_— \ N N / 1 \ \ —....I '^I\i 11 ��D;\ I oQ=�o�d�u�io LL� o O S Opel L 03 i i w ° °> o¢ / \ \ 0-0 i0 SURD >'O a'� ¢ E z off MOST HYDRAULICALLY REMOTE HEADS t \ \ \ pUpz¢uo o°„ ° WINDOW / Vii. \ / I I\ \ , ri l Garage (o',) o 'zmooxoQ�¢rN, HEAD# GPM PRESSURE REQ'D AT STREET TV NICHE Ear W - tL / 1: 3' jt8 \ arc OCCUPANCY Y�°•zz Jw 1 HEAD H.14 17 39.05 AT+36" s:dz 61,4 �qEL w 'I� � r\ '�) / os� N FINISH ' B w�N'gyFa Ew°°m° a 2 HEAD H.3&H.2 26.0041 58.88 A.F.F. 24' A.F. PITCH"PIT ' 1 µ 1 CEILING FIMSH i e 1"`E a w o U 5'W 6 o H \ 2 r WAiL/ /R 2I BATT I AUL. ( �>�, III A7 \r "Ibl _ °0 IRE-TAPE-At--OW8 tONiozao ."uw w RC- ES-16 S- , , OP` 8Ur T/ qj CCL, 1 N 7'AR AP BEAMS BELOW CEILINF LEVEL ¢u u? °a R � 6 Tt l J 7ELENC �N7 V FIREPLACE") I INSULATE FLOOR ADODF �. H ti,, r; T� THRU� 16� ER \ � v2 1st Floor 5 '� \.- C� / I \ \R �SH'`I FI-�fri(;t k61VE 13 2nd Floor i0.4, ,.,I 4 C U 1 1�I �E�, I"1 4 \ 1•,pl - \ .. 1 3rd Floor I 'n a5t •edro U • '/ II' /-(OP ` SELF LJ`Si G _ 16 TOTAL �D) a / 115 1 � 1 -._._I L007 J013Z aND ROOF�RAFTERS \ �S AV F n,N 1$ 20 MIN'N (I 1 1 RCCF A /P ENC ASURF - el.e LF SENJU SPRINKLER Model RC-RES Flat Concealed Pendent Quick Response o 1 K=4.9, 162F°,7/16"Orifice,Maximum Spacing 16'x16' �, aFLOw�I Li ng Loo o ER \ OFFICE COPY 0 - - - 15 P 9 N L—_ J J HEATS 'Pr -- D 'PACES I RC-RES-16 Sprinkler head demand. 13 gpm @ 7.04 Ls�— I 7 � i l�- � '.tp N 13� LV _. 1 ,!, 7 5✓2 / F'.el 12., 13 3,-g. 8,� 6 / 'r` \ 1 ON SULATE LF SENJU SPRINKLER Model RC-RES Flat Concealed Pendent Quick Response a111 i \ ® - - - 1 K=4.9, 162F° 7/16"Orifice,Maximum Spacing 18'x18' 5,`+` f =rl - i 1 ��� 1 ( 1-r-- -: - I ' i T,1'I `L'A - uNDER , ,f.....es.,- ' RC-RES-18 Sprinkler head demand: 17 gpm @ 12 2 1 L '-�� 1 T,20 1 ,, \4;11 S TJ22 o / .19 ;r ,� c.�. ti 'SHOWER 1 �° • (4',1-4-(:),,,_, 1 iIRR DOWN FOR DUCT nUN II g.r ULL, 1 ,1=,:r#w =1, -''7;1'! I / r\ 5'-2/2 9' 9/2 1 F 1J_ u�M, 1 �Iiath 1' -Rr - 6' - -` I ;t I -4 fREAJ P SAX.RISER j q 1I� _ r IN 7 1— -..._- \ E- �8 (,AD OR OR REMOVE le 4 AN7� i *ck E 164 teii'IA _ luul • 'I T.21 M. 11� ��— STENS 5 REQU E PER �U� m 81 •^R .k-E 1. �45/i- /-\ 1 X11 2e6L'V�AJAL A. • 1IF ;---,SITE (➢N N A =� H 911 __ :.1 >i, ,� ?l?�I-i \ I A.E l .1 MIMr-� (( 11��1 ..z 6 • �I — �I ,., PY=t 1 ,3 ,- �!� I_---- ti ' FI'�2 _ .o -��(� .th�:� �� '1 , .I N, F. '" ( I -ll � � in l'I'I �ll I��,D� ii /, �-1 cv li'' gig I ,�x •� z -o, ,� ,o I ,� Ill -RE-16 i A �� I s &UB ,i 111 T.29l ;-I I� ' '� I. 24 m L O o m v F N /.._ IIIA \ 7 Iii :•_ '51 P2 w H E - / air TO BE�OW�� 2 _ Bath II _- II ('i h o :. 1 LOCATE r UMBI J ,ate z a R 3 i6"I 3 g:. ? 9 <s a ! �— / l J E ROUOF' I a L`tTll W w O i'' 1 Y 1..-� T.33 Entry-Ma: P� FOR r2; S�W3 O wAL a ELEV=109' LJ i+V ` .�s 11) _ .-1 r-.1 ■R T.. s'' vv�� ■ • �OITI 3 a F F Q u EXTERIOR WALL I" -'4 .l' ,C, .' J .• �� _ 0(EU C_ J, r=u a i STATIC: 67psi �� o -,&FOLD 1� 7 _,1 1 to 1 -CO TINUL ARTY WALL Ir R•I`* I M f °,o pvP CY OOz�ax nw TyPv;AL RESIDUAL: 51psi ",L ,KtS 16 �. i1 _ - � 60 . r9iHRetJ uRRwc `�, ,-f' $-'� �1 o u 8 a a m o o y FLOW RATE: 36509Pm // s 1"AquaPEX e'-1 /� 3-s,2° 11 Trp, "`III ' !0 :F.1T38 \SERC RES 16 1 4 I / 1(4 •1M OATERHEATER Tech Rfll. / I �:�11� >33 Din. Fam.R=1u aN S;slru I1 ` ncula a A l T,P. 11 Pw l : �� j I Il z F.2' ELEV=104' ADI I PROVIDE .C�{�{� 2 ���, �� REDUCTION D - H D ¢ / 0 TC ENSUR ON W--A �I; �R Dr_ ` Jr SYSTEM ' O M w o I it REOLL rIGN -- o c BALL VALVE �pT PROPER E;- SS WIDTH - 03 D7 1 ,L sYSTEM CRE - 1 I ?- o w a w 1 1/4"FULL PORT e n D0) �I M� - 2.-1Y2"Iz'-1Y2` EGRESS LL 1 m ° _ R e p H 1-9 CYST 1-e y 7.- e 3-0 F RC-RES-16 416 e9Fp ' � .�� > w , .. / AS J. 4-e F EGRESS 4_e F - AT 67-01"34321 4PND F- 1 -6 .,_JT - i� W LLJ f in.. m �// ORE DIVALENT 1 ��w� Porch 20 a o j 00------1-1/4"APOLLO 36H PRV ����! o Q \ HI ZI—I V Amo o"' ELEV=100 ELEv=loo' j////////��1 I LOSS FLOWING 26GPM) �� FIRST FLOOR -1 ~ 1, `_i S 0 - 1"METER �3 THIRD FLOOR � z '\, SECOND FLOOR 10. LL I SHEET DESCRIPTION 35'OF 50'OF F100// = , „ F100;% = F100 = , ,1 1"COPPER-K 1-1/4"AquaPEX1/4" 1'-0" � i 1/4" l'-0" \_/ 1/4" l'-0" ALL LEVELS it SI "4 WATER SERVICE DETAIL 5 0 5 15 SHEET NUMBER IIMMIIIIIIMI F100 NTS F100 , © UPONOR - CONFIDENTIAL 1i Senju RC-RES:Open Web Truss/TJI Construction Insulation Recommendations N A uaSAFETMGENERALNOTES• In areas subject to freezing,care should be taken in unheated attic spaces See General Notes 8.2.5.7 for Architectural `7 ProPEX LF Brass Fire to cover Uponor AquaPEX tubing completely with insulation. Insulation Feature Requirements 2 Sprinkler Adapter Tee should follow the guidelines of the insulation manufacturer. See Uponor %MBz 1. THIS SYSTEM IS DESIGNED AS PER NFPA 13D 2016 EDITION AS A RESIDENTIAL MULTIPURPOSE SYSTEM Blocking Maybe Fire Sprinkler Adapter Document"Uponor AquaSAFE Attic Insulation Guidlines"for attic O SECTION 3.3.11.3. Required.If -- P -on Nut installation guidelines(Provided in Contractors Documents package or online ` / o 'w V Blocking is Used, ' 1 at www.Uponorpro.com). p 2. UPONOR COMPANY RESERVES THE EXCLUSIVE RIGHTS TO ALL DETAILS AND DRAWINGS AS SHOWN ON ..1- 1/a"Min. I I ^z Use The 2 Top THIS SHEET. THESE DETAILS AND DRAWINGS ARE PROPRIETARY INFORMATION OF UPONOR COMPANY AND / 11/Z'Max. a Screw Holes. r Bottom of Mounting Extreme Temperature Installations Planter Box Window,Bay Window or Similar Feature. C .. f UNAUTHORIZED USE MAY BE SUBJECT TO PROSECUTION TO THE FULL EXTENT OF THE LAW. racket to Face of Truss P If no additinal floor area is created No Additional Sprinkler is Required. ft-r,-,-.,©o AquaSAFE Residential Fire Safety systems are often installed in attics or < w¢ 3. THE DESIGN OF THIS SYSTEM IS DICTATED BY SPECIFIC CEILING HEIGHTS AND ROOM SIZES. IT IS THE Fire Sprinkler Adapter -1 - other areas exposed to temperature extremes of heat and/or cold. Follow 8'-0"or less O N ry u 0 RESPONSIBILITY OF THE INSTALLING CONTRACTOR TO ENSURE THAT THE CONDITIONS SHOWN ON THESE Mounting Bracket I .1�''// I the recommended extreme weather installation instructions to isolate and / m PLANS ARE EXACTLY AS THEY EXIST IN THE FIELD. DEVIATIONS FROM THE DESIGN MAY CAUSE THE l ��J protect system components from extreme temperatures. Because this RC-RES-16_ • a0,P v_w O SYSTEM TO BE UNABLE TO CONTROL A FIRE.IF THE BUILDING CONSTRUCTION DIFFERS FROM THE FIRE system also delivers domestic cold water directly to plumbing fixtures, u v,p vi O SPRINKLER PLAN,CONTACT THE SYSTEM DESIGNER IMMEDIATELY. 3-#10 x 1/2"�-t -� - 9'-0"or less ® N� j z a } Uponor highly recommends that you protect the tubing with adequate / Iz u', 0 Full Course f,T� i insulation in warm weather areas to minimize heating of the cold water o 5 LT,'.. 3 4. THIS SYSTEM AND THE ACCOMPANYING HYDRAULIC CALCULATIONS ARE DESIGNED IN COMPLIANCE WITH Thread Strews ll� supply. '" Z W'0 NFPA 13D 2016 EDITION. In Bottom Holes ` o w / o O N »3 S. "STAND-ALONE"OR"MULTIPURPOSE,WET PIPE"SYSTEMS ARE NOT PERMITTED TO USE ANTI-FREEZE. - = \ Installation methods include,but are not limited to: I °\ I m\ W m m I w • Tenting over the fire sprinkler piping. 0 in I-w 3 Lead-Fre Fiat ` 6. MODIFICATIONS ARE PROHIBITED.SPRINKLERS THAT HAVE BEEN PAINTED,CAULKED,MODIFIED OR < n,t l - • Additional layers of batt insulation. If additional floor area is created.Cannot exceed 18 fP,be more than 2'-0" ConcealedSenju ` Concealed Flat • Increased depth of blown in insulation. deep,more than 9'-0"wide and be with in the coverage area of the o DAMAGED MUST BE REPLACED. p 9 Sprinkler Head Cover Plate sprinkler.No Additional Sprinkler is Required. z w o w. o F F w 7. WATER SHUT OFF VALVE IS NOT PERMITTED THAT ISOLATES THE SPRINKLER SYSTEM. Caution: If you will be installing spray foam insulation,make sure to o 00 z i 2 o O F 8. OWNERS MANUAL MUST BE PROVIDED TO THE OWNER. Senju RC-RES:Traditional Wood Framing Construction Protect all components during application.Consult with the spray foam d u° 0 0 o w m z w manufacturer to ensure compatibility with all products before application. NFPA 13D Table 7.5.5.3 Distances From i d u a r><0.o d o o z 9. AT THE MAIN SHUT OFF VALVE,A TAG OR A SIGN STATING THE FOLLOWING IS REQUIRED;"WARNING,THE Heat Sources .,,,,,.7-<0,^',a1 .0_o z Consultation with local building officials is encouraged to ensure compliance 00>- 't2 E J o WATER SYSTEM FOR THIS HOME SUPPLIES FIRE SPRINKLERS THAT REQUIRE CERTAIN FLOWS AND .w m o°1 u PRESSURES TO FIGHT A FIRE.DEVICES THAT RESTRICT THE FLOW OR DECREASE THE PRESSURE OR ProPEX L'Brass Fire with local building codes. ' o i° I- u z o 3-a Fire Sprinkler Adapter Ordinary Intermediate . -'`` >-,?,z 0 00 N AUTOMATICALLY SHUT OFF THE WATER TO THE FIRE SPRINKLER SYSTEM,SUCH AS WATER SOFTENERS, Sprinkler adapter Tee ` o p _ _ _ Heat Source Temp. Temp. dz z o`��d • • FILTRATION SYSTEMS AND AUTOMATIC SHUT OFF VALVES,SHALL NOT BE ADDED TO THIS SYSTEM Y/---Push-on Nut - p o¢ m '' 135°-170° 175°-225° zwp2a aoi-mz • • WITHOUT REVIEW OF THE FIRE SPRINKLER SYSTEM BY A FIRE PROTECTION SPECIALIST.DO NOT REMOVE `-J- o z �. Bending PEX Tubing Side of Fireplace 36" 12" z o. °z z o 0 3 A u THIS SIGN". ! p C °aw5> "z i 1/q'Min. The minimum bend radius of Uponor PEX tubing in any direction is six times Front of Fireplace 60" 36" W m o m >2 3<u • 10. ALL INTERIOR PIPING TO BE UPONOR"AquaPEX®"UNLESS NOTED. --,- �. 11/2 Max. the outside diameter(6 z OD). ❑u . w • Bottom cf MountingWood Burning Stove 42" 12" z-o¢ -z" -h Fire Sprin ler Adapter- - Bracket to-ace of Trussi Bend supports are available for rigid bends.1/2",3/4"and 1"Uponor AquaPEX Kitchen Range 18" 9" N a r 2 z z-.o o f-x 0 3 z 11. UPONOR"AquaPEX"TUBING TO BE SUPPORTED PER NFPA 13D AND MANUFACTURER'S RECOMMENDATIONS. Mounting Bracket tubing to facilitate 90-degree 9 z Q g o o�, ¢ 2 0 2 0 O\�_._J ® Wall Oven 18" 9" V a¢a"aw_,w`h1`,t¢ i 12. MINIMUM SPACING BETWEEN SPRINKLERS IS 8'-0" REFER TO SPACING CHARTS FOR MAXIMUM SPACING 2-#10 x I.1/2" Recommended Between V)w h u LL °❑>o'o u z r u Tubing LengthFittingsHut Air Flues 18" 9" M a d z z z a v= BETWEEN SPRINKLERS AND FROM WALLS.SPRINKLER HEAD MANUFACTURERS MAY HAVE MORE Full Cour-- i !; } F z z a 0 0 I t Fitting Size Minimum Tubing Length Uninsulated Heat Ducts 18" 9" 13 m z o w RESTRICTIVE SPACING LIMITATIONS. Thread 5,rows s r_s �"->z z d In Top H.les 17 r �-I� Uninsulated Hot Water Pipes 12" 6" 4iF raz[-Ni°p:;52 7 V_V CJ 3/8"ProPEX Fitting 2° 0 3,, �,z, o 5 o 13. SPRINKLERS ARE NOT NECESSARILY CENTERED IN ROOMS DUE TO LIGHT FIXTURES OR OTHER CEILING Side of Hot Air Diffuser 24" 12" 6'.1W-0, 4.,M,- MOUNTED 0 0 0`✓ h MOUNTED OBSTRUCTIONS. 1/2"ProPEX Fitting 2 1/2" ?i a° 2`-o_ z \ Front of Hot Air Diffuser 36" 18" '''El l i-. a o'o 14. THE PLUMBING TIE IN CONNECTIONS ARE SCHEMATIC IN NATURE AND CAN BE INSTALLED OFF THE Lead-Fre=Flat _ °v 3/4"ProPEX Fitting 3 1/2" Hot Water Heater 6" 3" 0 z 022 u $a u o o z 0,4,70,0 w 0 m SPRINKLER LOOP ANYWHERE BETWEEN SPRINKLER TO SPRINKLER CONNECTION. Conceale.SenJu -'t.," 'ru i 1"ProPEX Fitting 4 1/2" Furnace " " o 0 o o r a>a Fr Concealed Flat omi 0 Sprinkler Head Cover Plate 1 1/4"Pr0PEX Fitting 5 1/2" 50W-250W Light Fixture 6" 3" '.''''' ,T,22 5 o m 15. THIS SUGGESTED LAYOUT IS BASED UPON INFORMATION PROVIDED BY OTHERS. CHANGES IN 250W-499W Light Fixture 12" 6" w f i o o u u z i o_ CONSTRUCTION OR FIELD CONDITIONS MAY OCCUR WHICH MAY REQUIRE CHANGES TO THE LAYOUT. IT IS g 5>F 0 y 3 LL w F S o 0 o THE RESPONSIBILITY OF THE INSTALLER TO NOTIFY UPONOR TECHNICAL SERVICES OF SUCH CHANGES. \ F a 2$o z<o a aw 2 2 2 w Exposed Installation Requirements. ` z ° a 16. NFPA 13D 8.2.5*OBSTRUCTIONS TO RESIDENTIAL SPRINKLERSt • 8.2.5.6* SHADOW AREAS SHALL BE PERMITTED IN THE PROTECTION AREA OF A SPRINKLER AS LONG AS Uponor AquaPEX°°tubing(white)and ProPEX'"EP Fittings and ProPEXT"' I m THE CUMULATIVE DRY AREAS DO NOT EXCEED 15 FTS PER SPRINKLER. Brass Fittings are approved for exposed installation where the following • 8.2.5.7 SMALL AREAS CREATED BY ARCHITECTURAL FEATURES,SUCH AS PLANTER BOX WINDOWS,BAY conditions are met.(UL 1821 Approved) WINDOWS,AND SIMILAR FEATURES,SHALL BE EVALUATED AS FOLLOWS: /�❑Um (1)WHERE NO ADDITIONAL FLOOR AREA IS CREATED BY THE ARCHITECTURAL FEATURE,NO Exposed Wood Joist Ceiling Assemblies. 8 ADDITIONAL SPRINKLER PROTECTION IS REQUIRED. 1. Joists are of dimensional lumber,engineered wood,wood I-joist or open �' T (2)WHERE ADDITIONAL FLOOR AREA IS CREATED BY AN ARCHITECTURAL FEATURE,NO ADDITIONAL web wood joists. m SPRINKLER PROTECTION IS REQUIRED,PROVIDED ALL OF THE FOLLOWING CONDITIONS ARE MET; 2. Joist are of depths from 6-16 inches(152-204 mm). (a)THE FLOOR AREA SHALL NOT EXCEED 18 FT°(1.7 M2) 3. Joist are of spacing from 12-24 inches(305-610 mm)on center. Q❑ (b)THE FLOOR AREA SHALL NOT BE GREATER THAN 2 FT IN DEPTH AT THE DEEPEST POINT OF 4. Joists can be exposed after installation. \ Hr THE ARCHITECTURAL FEATURE TO THE PLANE OF THE PRIMARY WALL WHERE MEASURED 5. Metal pipe hangers spaced at maximum 24 inches(610 mm)on center jr 1.55" 1.66" ALONG THE FINISHED FLOOR. are used. (c)THE FLOOR SHALL NOT BE GREATER THAN 9FT IN LENGTH WHERE MEASURED ALONG THE 6. Listed residential automatic sprinklers of maximum activation 1° -3n Hanger 1" Hanger PLANE OF THE PRIMARY WALL. temperature rating of 155.F(68.C). (d)MEASURED FROM THE DEEPEST POINT OF THE ARCHITECTURAL FEATURE TO THE SPRINKLER SHALL NOT EXCEED THE MAXIMUM LISTED SPACING OF THE SPRINKLER. Metal Tubing Support. Tubing Support Spacing: (3)THE HYDRAULIC DESIGN SHALL NOT BE REQUIRED TO CONSIDER THE AREA CREATED BY THE 1. Metal supports (Anchor AquaPEX Tubing Securely Enough to Support the Tubing,Yet Relaxed ARCHITECTURAL FEATURE. tubing designed for plastic tubing shall be used. Enough to Allow the Tubing to Expand and Contract) 2. Do not use supports that will damage the tubing.Inspect metal 17. NFPA 13D 6.3 LOCATION OF SPRINKLERS. supports for sharp edges. 1. Along Horizontal Runs,Install Supports Every 32",if Horizontal Runs are • 8.3.1 SPRINKLERS SHALL BE INSTALLED IN ALL AREAS EXCEPT WHERE OMISSION IS PERMITTED BY 8.3.2 3. Do not rigidly anchor Uponor AquaPEX'"tubing with supports.Allow Continuously Supported,Place Tubing Supports at Six-Foot Intervals. enough tubing for freedom of movement to expand and contract. THROUGH 8.3.8. 2. Along Vertical Runs,Install Supports Every Four to Five Feet,at Each • 8.3.2 SPRINKLERS SHALL NOT BE REQUIRED IN BATHROOMS OF 55 FT'(5.1 M')AND LESS Floor and at a Mid-story Guide. z • 8.3.3 SPRINKLERS SHALL NOT BE REQUIRED IN CLOTHES CLOSETS,LINEN CLOSETS,AND PANTRIES THAT c,-,5 z MEET ALL OF THE FOLLOWING CONDITIONS: In-line Flow Test (1)THE AREA OF THE SPACE DOES NOT EXCEED 24 FT'(2.2 M'). The In-line Flow Test can be Constructed on site. It performs a flow test to a i o '.^. (2)THE WALLS AND CEILINGS ARE SURFACED WITH NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE High Upstream Pressure ensure proper system operation and flow(see Figure FOGS-8). 0 ,"-, MATERIALS AS DEFINED IN NFPA 220,STANDARD ON TYPES OF BUILDING CONSTRUCTION. If the upstream pressure exceeds 80 psi a pressure reducing valve may YE w n ',_°, • 8.3.4* SPRINKLERS SHALL NOT BE REQUIRED IN GARAGES,OPEN ATTACHED PORCHES,CARPORTS,AND need to be installed. Some jurisdictions may require a pressure reducingm n 0 u m ., SIMILAR STRUCTURES valve regardless of upstream pressure. Uponor AquaPEX O o m i't w n • 8.3.5 SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE,PENTHOUSE V Tubing 7 ¢ m~m ., • EQUIPMENT ROOMS,ELEVATOR MACHINE ROOMS,CONCEALED SPACES DEDICATED EXCLUSIVELY TO AND w z Q mo CONTAINING ONLY DWELLING UNIT VENTILATION EQUIPMENT,FLOOR/CEILING SPACES,ELEVATOR SHAFTS, / j W O I CRAWL SPACES,AND OTHER CONCEALED SPACES THAT ARE NOT USED OR INTENDED FOR LIVING z LL PURPOSES. - U 0 g J 8.3.5.1 SUCH SPACES THAT CONTAIN FUEL-FIRED EQUIPMENT SHALL ALSO COMPLY WITH 8.3.5.1.1 OR z a ~ ~V - 0 8.3.5.1.2. - a a z O m ¢ • 8.3.5.1.1 WHERE THE FUEL-FIRED EQUIPMENT IS ABOVE ALL OF THE OCCUPIED AREAS OF THE DWELLING I j M Y ¢ 3 UNIT,NO SPRINKLER PROTECTION SHALL BE REQUIRED IN THE CONCEALED SPACE. % z a O o 'E 8.3.5.1.2 WHERE FUEL-FIRED EQUIPMENT IS BELOW OR ON THE SAME LEVEL AS OCCUPIED AREAS OF THE �� � Ce N o8 o8 Ou a a vsi z o Male Threaded Coupling ProPEX Fire p �- DWELLING UNIT,AT LEAST ONE QUICKRESPONSE INTERMEDIATE TEMPERATURE SPRINKLER SHALL BE Sprinkler Adapter N a 00 INSTALLED ABOVE THE EQUIPMENT OR AT THE WALL SEPARATING THE SPACE WITH THE FUEL-FIRED Ce 0 °1 EQUIPMENT FROM THE OCCUPIED SPACE. 11...�� o 0 1"Ball Valve a • 8.3.6 SPRINKLERS SHALL NOT BE REQUIRED IN COVERED,UNHEATED PROJECTIONS OF THE BUILDING AT --To Hot Water Heater Male Threaded Coupling - I I 1 a > `9 ENTRANCES/EXITS AS LONG AS THE DWELLING UNIT HAS ANOTHER MEANS OF EGRESS. "�> -� L.LI �� w • 8.3.7 SPRINKLERS SHALL NOT BE REQUIRED FOR CEILING POCKETS THAT MEET THE FOLLOWING - Female Threaded m r� , Tee with Water i� z CONDITIONS: _ ,� 1 THE TOTAL VOLUME OF ALL UNPROTECTED CEILING POCKETS IN A COMPARTMENT DOES NOT EXCEED Pressure Gauge �i 0 ,8 o 0 a ( ) n '" Pressure Gauge Sprinkler Orifice -•- (Optional) p 100 FTs(2.83 Ms). m _ I I /'� z z ry d (2)THE ENTIRE FLOOR UNDER THE UNPROTECTED CEILING POCKET IS PROTECTED BY THE SPRINKLERS 5 _ Ce w m¢> u1 C. AT THE LOWER CEILING ELEVATION. EI `ti°z '0 o S (3)*THE INTERIOR FINISH OF THE UNPROTECTED CEILING POCKET EXCLUDING DECORATIVE .c Main Fire Sprinkler Flowens Test W C) ¢ TREATMENTS IS NONCOMBUSTIBLE OR LIMITED-COMBUSTIBLE MATERIAL. In A - Shut-off Valve To ensure the system provides enough water for proper fire sprinkler w °i w f ut'i (4)SKYLIGHTS NOT EXCEEDING 32 FT'(2.97 Mz)SHALL BE PERMITTED TO HAVE A PLASTIC COVER. w performance,you should conduct a flow verification test. ,{ u, .r';". Q Uponor Warning Signs �; o • 8.3.8 SPRINKLERS SHALL NOT BE REQUIRED IN CLOSETS IN GARAGES AND EXTERIOR CLOSETS fa Note: The NFPA 13D Installation Standard does not require flow ~ f rl E m = `rw' p (REGARDLESS OF SIZE)LOCATED ON EXTERIOR BALCONIES,EXTERIOR BREEZEWAYS/CORRIDORS,OR - z \.! m 0 0 '� u_ ., verification. m ACCESSED FROM OUTDOORS WHERE THE CLOSET DOES NOT HAVE DOORS OR UNPROTECTED I"'I z Y 5 F PENETRATIONS DIRECTLY INTO THE DWELLING UNIT. u Pressure Reducing Before performing a flow verification test,confirm the water pressures by f 3 w=m • 8.3.9 SPRINKLERS SHALL BE INSTALLED IN ANY CLOSET USED FOR HEATING AND/OR AIR-CONDITIONING - z Valve contacting the Water and Sewer Department of your local city. Ensure the 2 p u 5 5 d z'" EQUIPMENT,WASHERS AND/OR DRYERS,OR WATER HEATERS EXCEPT AS ALLOWED BY 8.3.8. _ available water pressure matches the pressure used in the system design. F18. INSULATION GUIDE LINES PER NFPA 13D. - Note: The sprinkler plan indicates the most hydraulically remote sprinkler SHEET DESCRIPTION • 9.1.1*WET PIPE SYSTEMS IN AREAS ABOVE 40.F. A WET PIPE SYSTEM SHALL BE PERMITTED TO BE TO BE - 2 (or pair of sprinklers). For test requirements on other sprinklers,consult GENERAL NOTES&DETAILS zUSED WHERE ALL PIPING IS INSTALLED IN AREAS MAINTAINED ABOVE 40.F,INCLUDING AREAS PROPERLY a your local code. ,o ••INSULATED TO MAINTAIN 40.F. A.9.1.1 IN AREAS SUBJECT TO FREEZING,CARE SHOULD BE TAKEN IN UNHEATED ATTIC SPACES TO Note: It is a good idea to notify the fire inspector at least 24 hours prior to o, COVER SPRINKLER PIPING COMPLETELY WITH INSULATION. INSTALLATION SHOULD FOLLOW THE performing a Flow verification test. This may speed up the inspection GUIDELINES OF THE INSULATION MANUFACTURER.FIGURE A.9.1.1(A)THROUGH FIGURE A.9.1.1(F) process and eliminate the need to repeat the test for the inspector. SHEET NUMBER a SHOW SEVERAL METHODS THAT CAN BE CONSIDERED. THESE ARE FOR ILLUSTRATIVE PURPOSES ONLY. CONSULTATION WITH THE GENERAL CONTRACTOR AND/OR OWNER IS RECOMMENDED TO ENSURE Note: See"AquaSAFE Flow Test Instruction Sheet"(Provided in PROPER METHODS AND MATERIALS ARE USED TO MAKE SURE 40.F WILL BE MAINTAINED. Contractors Documents package or online at www.Uponorpro.com)for more information on Flow Test Setup,Assembly,Performing the Test and tii Troubleshooting. If there are any questions please contact Uponor. 80 psi © UPONOR - CONFIDENTIAL FO 0 1 L'.7'- PRV Set Pressure