Loading...
Report (10) /frt1 e,2-vI --‘) 4-15 Cr l Ste/ Stv creer I oc-Ikps s,,5., Generated by COMcheck-Web Software Mechanical Compliance Certificate Section 1: Project Information Energy Code:2009 IECCSEP 2016 Project Title: r,.( Project Type:Addition iii III rt,,,,,, r', 4-1,— . Construction Site: Owner/Agent: ��� " 'fF 9 Designer/Contractor: 16154 SW Upper Boones Ferry Rd Gohman Mechanical, Inc. Tigard,Oregon 97224 14505 SE Hwy 212 Clackamas,Oregon 97015 503-658-1892 Section 2: General Information Building Location(for weather data): Tigard,Oregon Climate Zone: 4c Section 3: Mechanical Systems List Quantity System Type&Description 1 HVAC System(Unknown): Heating: 1 each-Central Furnace,Gas,Capacity=72 kBtu/h ' Proposed Efficiency=80.00%Et,Required Efficiency=80.00%Et Cooling: 1 each-Single Package DX Unit,Capacity=47 kBtu/h,Air-Cooled Condenser, Unknown Economizer Proposed Efficiency=0.00 SEER, Required Efficiency=13.00 SEER SYSTEM COMPLIANCE FAILS:PROPOSED EFFICIENCY FAILS TO MEET CODE REQUIREMENTS. Section 4: Requirements Checklist Requirements Specific To: HVAC System : vi 1. Equipment minimum efficiency: Central Furnace(Gas): 80.00%Et(or 78%AFUE) 2. Equipment minimum efficiency: Single Package Unit: 13.00 SEER Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Plant equipment and system capacity no greater than needed to meet loads Exception(s): ❑ Standby equipment automatically off when primary system is operating ❑ Multiple units controlled to sequence operation as a function of load 2(2. Minimum one temperature control device per system ❑ 3. Minimum one humidity control device per installed humidification/dehumidification system 24. Load calculations per ASHRAE/ACCA Standard 183. . Automatic Controls:Setback to 55°F(heat)and 85°F(cool);7-day clock,2-hour occupant override, 10-hour backup Exception(s): ❑ Continuously operating zones 56(6. Outside-air source for ventilation;system capable of reducing OSA to required minimum ~ 1. R-5 supply and return air duct insulation in unconditioned spaces R-8 supply and return air duct insulation outside the building R-8 insulation between ducts and the building exterior when ducts are part of a building assembly Exception(s): ❑ Ducts located within equipment ❑ Ducts with interior and exterior temperature difference not exceeding 15°F. Project Title: Data filename: Report date: 09/12/16 Page 1 of 2 In 8. Mechanical fasteners and sealants used to connect ducts and air distribution equipment ±(9.`Ducts sealed-longitudinal seams on rigid ducts;transverse seams on all ducts;UL 1S1A or 1818 tapes and mastics 10.Hot water pipe insulation: 1.5 in.for pipes<=1.5 in.and 2 in.for pipes>1.5 in. Chilled water/refrigerant/brine pipe insulation: 1.5 in.for pipes<=1.5 in.and 1.5 in.for pipes>1.5 in. Steam pipe insulation: 1.5 in.for pipes<=1.5 in,and 3 in.for pipes >1.5 in. Exception(s): Li Piping within HVAC equipment. D Fluid temperatures between 55 and 105°F. Li Fluid not heated or cooled with renewable energy. Li Piping within room fan-coil(with AHRI440 rating)and unit ventilators(with AHRI840 rating). Runouts<4 ft in length. '11.Operation and maintenance manual provided to building owner '2.Thermostatic controls have 5°F deadband Exception(s): Li Thermostats requiring manual changeover between heating and cooling • Special occupancy or special applications where wide temperature ranges are not acceptable and are approved by the authority having jurisdiction. ry13.Balancing devices provided in accordance with IMC 603.17 D 14.Demand control ventilation(DCV)present for high design occupancy areas(>40 person/1000 ft2 in spaces>500 ft2)and served by systems with any one of 1)an air-side economizer,2)automatic modulating control of the outdoor air damper,or 3)a design outdoor airflow greater than 3000 cfm. Exception(s): O Systems with heat recovery. Li Multiple-zone systems without DDC of individual zones communicating with a central control panel. Li Systems with a design outdoor airflow less than 1200 cfm. Li Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 15.Motorized,automatic shutoff dampers required on exhaust and outdoor air supply openings Exception(s): ❑ Gravity dampers acceptable in buildings<3 stories • 16.Automatic controls for freeze protection systems present • 17.Exhaust air heat recovery included for systems 5,000 cfm or greater with more than 70%outside air fraction or specifically exempted Exception(s): Hazardous exhaust systems,commercial kitchen and clothes dryer exhaust systems that the International Mechanical Code prohibits the use of energy recovery systems. Systems serving spaces that are heated and not cooled to less than 60°F. jJ Where more than 60 percent of the outdoor heating energy is provided from site-recovered or site solar energy. O Heating systems in climates with less than 3600 HDD. J Cooling systems in climates with a 1 percent cooling design wet-bulb temperature less than 64°F. 0 Systems requiring dehumidification that employ energy recovery in series with the cooling coil. Li Laboratory fume hood exhaust systems that have either a variable air volume system capable of reducing exhaust and makeup air volume to 50 percent or less of design values or,a separate make up air supply meeting the following makeup air requirements: a)at least 75 percent of exhaust flow rate,b)heated to no more than 2°F below room setpoint temperature,c)cooled to no lower than 3°F above room setpoint temperature,d)no humidification added,e)no simultaneous heating and cooling. 1 Project Title: Report date: 09/12/16 Data filename: Page 2 of 2