Report (11) F r°5?-vlt. -Dors :,- 0.&•lU sGt, /ZJSf'i rJet 0104-` OFFICE COPY i61,1' ELECTRICAL HEATING FIRE PROTECTION PLUMBING MAINTENANCE WOOD PRODUCTS "Solutions„for a streamlined project" s PROS mal"if 4: if_ ���.�� ► li el2 441 15, LYNN S ' I EXPIRES:b/c of Jet Fire Protection 1935 Silverton Rd. NE Salem, OR 97301 503 588-5262 Job Name : Nix Residence Building : Residence Location : 12610 SW 121st. Ave. System : 1 Contract : F16-0279 Data File : Nix Residence.wxf Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Jet Fire Protection Page 1 ' Nix Residence Date 8/24/16 HYDRAULIC DESIGN INFORMATION SHEET Name - Nix Residence Date - 8/26/16 Location - 12610 SW 121st. Ave. System No. - 1 Building - Residence S Y Contractor - Jet Fire Protection Contract No. - F16-0279 Calculated By - Rich Rohr Drawing No. - FP 1.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height Varies OCCUPANCY - R-3 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( ) 1 (X)2 ( )4 ( ) S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make TYCO Model LF II I Elevation at Highest Outlet - 20 Feet Size 1/2" K-Factor 4.9 G Note: Temperature Rating 155 N Calculation Gpm Required 26.831 Psi Required 45.069 At Test Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 56 Elev. R Residual (Psi) - 51 Other Well Flow (Gpm) - 1220 Proof Flow Gpm S Elevation - P Location: 121st @ James St. P L Source of Information: City of Tigard Water Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C • Jet Fire Protection Page 2 Nix Residence Date 8/24/16 City Water Supply: Demand: Cl -Static Pressure : 56 D1 -Elevation : 5.197 C2 - Residual Pressure: 51 D2-System Flow : 26.831 C2 -Residual Flow : 1220 D2 -System Pressure : 45.069 Hose( Demand ) D3-System Demand : 26.831 Safety Margin : 10.927 150 140 130 P 120 R 110 E 100 S 90 s 80 U 70 ; R 60 H CI 4 C2 E 50 o D2 40 30 20 10 Q1.. ......... . .. . I . . . . • • • • . . . . I . . . . . . . . , . . . . . . . . , . . . . 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Jet Fire Protection Page 3 Nix Residence Date 8/24/16 Fitting Legend Abbrev. Name 1/2 % 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 N* CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVC Tee-Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 Zaa Ames 2000B Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary- STANDARD • Jet Fire Protection Page 4 Nix Residence Date 8/24/16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. HD1 10.0 4.9 7.0 na 12.96 0.05 256 7.0 1 12.0 K=K @ EQ1 7.09 na 12.96 2 12.0 K=K@EQ1 8.12 na 13.87 3 10.0 12.28 na 5 10.0 21.9 na 6 10.0 20.68 na 7 10.0 18.59 na 8 10.0 21.09 na 9 10.0 22.11 na 10 20.0 23.64 na 11 10.0 29.77 na 12 0.0 39.02 na 13 0.0 45.07 na The maximum velocity is 14.35 and it occurs in the pipe between nodes 3 and 7 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Jet Fire Protection Page 5 • Nix Residence Date 8/24/16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HD1 12.96 0.874 0.0 1.000 7.000 K Factor=4.90 to 150.0 0.0 0.0 0.0 EQ1 12.96 0.0940 0.0 1.000 0.094 Vel= 6.93 0.0 12.96 7.094 K Factor= 4.87 *BL1 1 12.96 0.874 4N 28.0 18.000 7.094 K Factor @ node EQ1 to 150.0 0.0 28.000 0.866 3 12.96 0.0939 0.0 46.000 4.321 Vel = 6.93 0.0 12.96 12.281 K Factor= 3.70 2 13.87 0.874 3N 21.0 10.000 8.117 K Factor @ node EQ1 to 150.0 0.0 21.000 0.866 3 13.87 0.1064 0.0 31.000 3.298 Vel = 7.42 3 12.96 0.874 20 6.0 11.500 12.281 to 150.0 0.0 6.000 0.0 7 26.83 0.3607 0.0 17.500 6.313 Vel = 14.35 0.0 26.83 18.594 K Factor= 6.22 *LOOP 5 -13.57 1.101 20 10.0 26.500 21.896 to 150.0 0.0 10.000 0.0 6 -13.57 -0.0332 0.0 36.500 -1.212 Vel = 4.57 6 0.0 1.101 4N 28.0 30.000 20.684 to 150.0 0 5.0 33.000 0.0 7 -13.57 -0.0332 0.0 63.000 -2.090 Vel = 4.57 7 26.83 1.101 7N 49.0 24.500 18.594 to 150.0 0 5.0 54.000 0.0 8 13.26 0.0318 0.0 78.500 2.498 Vel = 4.47 8 0.0 1.101 0 5.0 27.000 21.092 to 150.0 0.0 5.000 0.0 9 13.26 0.0318 0.0 32.000 1.019 Vel = 4.47 9 -26.83 1.101 0 5.0 1.500 22.111 to 150.0 0.0 5.000 0.0 5 -13.57 -0.0331 0.0 6.500 -0.215 Vel = 4.57 0.0 -13.57 21.896 K Factor= -2.90 *FEED,RISER,UG 9 26.83 1.101 N 7.0 33.000 22.111 to 150.0 20 10.0 17.000 -4.331 10 26.83 0.1172 0.0 50.000 5.859 Vel = 9.04 10 0.0 1.394 3N 24.0 18.500 23.639 to 150.0 0 6.0 30.000 4.331 11 26.83 0.0371 0.0 48.500 1.801 Vel = 5.64 11 0.0 1.394 Zaa 0.0 10.000 29.771 to 150.0 0.0 0.0 8.881 ** Fixed Loss= 4.55 12 26.83 0.0372 0.0 10.000 0.372 Vel = 5.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Jet Fire Protection Page 6 Nix Residence Date 8/24/16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12 0.0 1.394 4N 32.0 50.000 39.024 to 150.0 0.0 32.000 3.000 ** Fixed Loss =3 13 26.83 0.0371 0.0 82.000 3.045 Vel = 5.64 0.0 26.83 45.069 K Factor= 4.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqco Fire & Building Products rapid response® HOME FIRE SPRINKLER SYSTEM Technical Services: Tel: (800) 381-9312/Fax: (800)791-5500 Series LFII Residential Concealed Pendent Sprinklers, Flat Plate 4.9 K-factor General pressures, enabling smaller pipe sizes and water supply requirements. Description The Series LFII(TY3596)has been de- signed with heat sensitivity and water The Tyco® Rapid ResponseTM Series distribution characteristics proven to LFII (TY3596) Residential Concealed help in the control of residential fires Pendent Sprinklers are decorative,fast and to improve the chance for occu- response,fusible solder sprinklers de- pants to escape or be evacuated. 4111102 signed for use in residential occupan- The Series LFII (TY3596) Residen- cies such as homes, apartments, dor- tial Concealed Pendent Sprinklers are mitories,and hotels. shipped with a Disposable Protective The cover plate assembly conceals the Cap. The Protective Cap is temporar- � ;>,afa sprinkler operating components above ily removed for installation, and then the ceiling.The flat profile of the cover it can be replaced to help protect the plate provides the optimum aestheti- sprinkler while the ceiling is being in- cally appealing sprinkler design. In stalled or finished. The tip of the Pro- addition, the concealed design of the tective Cap can also be used to mark Series LFII (TY3596) provides 1/4 inch the center of the ceiling hole into plas- Sprinkler/Model (6,4 mm)vertical adjustment.This ad- ter board, ceiling tiles, etc. by gently justment provides a measure of flexi- pushing the ceiling product against Identification bility with regard to which the length of the Protective Cap. When the ceiling fixed pipe drops to the sprinklers must installation is complete the Protective Number be cut. Cap is removed and the Cover Plate The Series LFII are to be used in wet Assembly installed. SIN TY3596 pipe residential sprinkler systems for NOTICE one-and two-family dwellings and mo- bile homes per NFPA 13D; wet pipe The Series LFII (TY3596) Residential residential sprinkler systems for resi- Concealed Pendent Sprinklers de- dential occupancies up to and includ- scribed herein must be installed and ing four stories in height per NFPA maintained in compliance with this 13R;or,wet pipe sprinkler systems for document and with the applicable the residential portions of any occu- standards of the National Fire Pro- pancy per NFPA 13. tection Association, in addition to the The Series LFII (TY3596) has a 4.9 standards of any authorities having ju- (60,5) K-factor that provides the re- risdiction. Failure to do so may impair quired residential flow rates at reduced the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- IMPORTANT vices in proper operating condition. Always refer to Technical Data The installing contractor or sprinkler Sheet TFP700 for the `INSTALLER manufacturer should be contacted WARNING" that provides cautions with any questions. with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 MAY, 2008 TFP442 • Page 2 of 6 TFP442 ' Minimum Flowib)and Maximum Residual Pressure Coverage Maximum For Horizontal Ceiling Area(°) Spacing (Max.2 Inch Rise Ft.x Ft. Ft.(m) for 12 Inch Run) (m x m) 160°F/71°C Sprinkler 12 x 12 12 13 GPM(49,2 LPM) (3,7 x 3,7) (3,7) 7.0 psi(0,48 bar) 14 x 14 14 13 GPM(53,0 LPM) (4,3 x 4,3) (4,3) 7.0 psi(0,48 bar) 16x16 16 13GPM(60,6LPM) (4,9 x 4,9) (4,9) 7.0 psi(0,48 bar) 18 x 18 18 17 GPM(64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi(0,83 bar) 20 x 20 20 20 GPM(75,7 LPM) (6,1 x 6,1) (6,1) 16.7 psi(1,15 bar) (a)For coverage area dimensions less than or between those indicated,it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. (b)Requirement is based on minimum flow in GPM(LPM)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design Criteria Section for details. TABLE A NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA FOR THE SERIES LFII(TY3596)RESIDENTIAL CONCEALED PENDENT SPRINKLER Technical Support Cup Steel be acceptable to the Authority Having Cover Plate Copper Jurisdiction. Data Retainer Brass Cover Plate Ejection Spring System Type. Only wet pipe systems StainlessSteel may be utilized. Approvals: UL and C-UL Listed. NYC Approved tDuPont Registered Trademark Hydraulic Design. The minimum re- under MEA 44-03-E-2. quired sprinkler flow rate for systems designed to NFPA 13D or NFPA 13R The Series LFII Concealed Pendent Operation are given in Table A as a function of Sprinklers are only listed with the Se- temperature rating and the maximum ries LFII Concealed Cover Plates hav- When exposed to heat from a fire, the allowable coverage areas. The sprin- ing a factory applied finish. Cover Plate, which is normally sol- kler flow rate is the minimum required Maximum Working Pressure: dered to the Support Cup at three discharge from each of the total num- 175 psi(12,1 bar) points,falls away to expose the Sprin- ber of"design sprinklers" as specified kler Assembly. At this point the De- in NFPA 13D or NFPA 13R. Discharge Coefficient: flector supported by the Arms drops K=4.9 GPM/psi'12(70,6 LPM/bar112) down to its operated position.The fus- For systems designed to NFPA 13,the Temperature Rating: ible link of the Sprinkler Assembly is number of design sprinklers is to be 160°F/71°C Sprinkler with comprised of two link halves that are the four most hydraulically demanding 139°F/59°C Cover Plate soldered together with a thin layer of sprinklers. The minimum required dis- Vertical Adjustment: solder. When the rated temperature is charge from each of the four sprinklers 1/2 inch(12,7 mm) reached,the solder melts and the two is to be the greater of the following: Finishes: link halves separate allowing the sprin- •The flow rates given in Table A for kler to activate and flow water. NFPA 13D and 13R as a function of Refer to Ordering Procedure section. temperature rating and the maximum Physical Characteristics: Design Criteria allowable coverage area. Body Brass •A minimum discharge of 0.1 gpm/ Cap Bronze The Tyco® Rapid ResponseTM Series Saddle BrassLFII (TY3596) sq. ft. over the `design area" com- Sealing Assembly Residential Concealed prised of the four most hydraulically Beryllium Nickel w/Teflont Pendent Sprinklers are UL and C-UL demanding sprinklers for the actual Soldered Link Halves Nickel Listed for installation in accordance coverage areas being protected by Lever Bronze with the following criteria. the four sprinklers. Compression Screw Brass Note: When conditions exist that are Obstruction To Water Distribution. Deflector Copper or Brass outside the scope of the provided cri- Locations of sprinklers are to be in ac- Guide Pin Housing Bronze teria, refer to the Residential Sprinkler cordance with the obstruction rules of Guide Pins Stainless Steel Design Guide TFP490 for the manu- NFPA 13 for residential sprinklers. facturer's recommendations that may . TFP442 Page 3 of 6 Operational Sensitivity. The sprin- BODYp SEALING klers are to be installed relative to the (1/2"NPT) ASSEMBLY ceiling mounting surface as shown in yy A Figure 3. Sprinkler Spacing. The minimum CAP �� 47:ApA f�1� P P g• I iii' -,2/' i � SPRINKLER spacing between sprinklers is 8 feet I�;'i�` , 71 I WRENCHING m). spacing\� (2,4 The maximum s acin be- JIIIFl.uuI t,.����� I AREA tween sprinklers cannot exceed the SADDLE 4� W1 i length of the coverage area(Ref.Table iA) being hydraulically calculated (e.g., COMPRESSION maximum 12 feet for a 12 ft. x 12 ft. CUP WITHSCREW coverage area, or 20 feet for a 20 ft. x ROLL FORMED 20 ft.coverage area). THREADS The Series LFII must not be used in k _ � /1 '� LEVER applications where the air pressure ��� i� I•� ` above the ceiling is greater than GUIDE I '. _�.' I that below. Down drafts through PIN •—■—•—■—•—" I the Support Cup could delay sprin- I ��'- ' ' 1 SOLDER LINK kler operation in a fire situation. ELEMENT GUIDE PIN 1 I HOUSING 1 DEFLECTOR J .— - L (OPERATED DEFLECTOR i ____ -- _ I POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY WRENCH I 1 1 RECESS THREAD INTO I I RETAINER SUPPORT CUP i WITH THREAD UNTIL MOUNTING 9 I DIMPLES �4��r�''\ SURFACE IS l, 0 ` %IAI III FLUSH WITH ) EJECTION CEILING SPRING I MP _� - PUSH WRENCH —_�J IN TO ENSURE ENGAGEMENT SOLDER COVER PLATE/RETAINER COVER WITH SPRINKLER TAB ASSEMBLY PLATE WRENCHING AREA FIGURE 1 FIGURE 2 SERIES LFII(TY3596)RESIDENTIAL W-TYPE 18 CONCEALED PENDENT SPRINKLER SPRINKLER WRENCH 2-1/2"DIA. SPRINKLER- (63,5 mm) 1/2"(12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING ` / OPERATED SPRINKLER __1 emil il, i 1-7/8"t1/8" PICOVER ��� — (47'6 mm PLATE JTF � - I 1/8"GAP ±3,2 mm)II RETAINERn 0 � (3,2 mm) 111.1.111.1,1111 7/8"(22,2 mm) ill COVER- SPRINKLER- MOUNTING 1-1/8"(28,6 mm) RETAINER SUPPORT CUP 3/16" SURFACE . _.I ASSEMBLY ASSEMBLY (4,8 mm) III 3-3/16"DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 SERIES LFII(TY3596)RESIDENTIAL CONCEALED PENDENT SPRINKLER INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR Page 4 of 6 TFP442 Installation ify or repair a damaged sprinkler. Care must be exercised to avoid dam- Step 6. Screw on the Cover Plate As- age-before, during, and after installa- The Series LFII (TY3596) must be sembly until its flange comes in con- tion.Sprinklers damaged by dropping, installed in accordance with the tact with the ceiling. striking, wrench twist/slippage, or the following instructions: like,must be replaced. Do not continue to screw on the Cover The owner is responsible for the in- NOTICE Plate Assembly such that it lifts a ceil- spection, testing, and maintenance of Damage to the fusible Link Assembly ing panel out of its normal position. their fire protection system and devic- during installation can be avoided by If the Cover Plate Assembly cannot es in compliance with this document, handling the sprinkler by the support be engaged with the Mounting Cup as well as with the applicable stan- cup only(i.e., do not apply pressure to or the Cover Plate Assembly cannot dards of the National Fire Protection the fusible link Assembly). be engaged sufficiently to contact the Association(e.g.,NFPA 25),in addition ceiling, the Sprinkler Fitting must be to the standards of any other authori- A 1/2 inch NPT sprinkler joint should repositioned. ties having jurisdiction. The installing be obtained with a minimum to max- contractor or sprinkler manufacturer imum torque of 7 to 14 ft.lbs. (9,5 to should be contacted relative to any 19,0 Nm). Higher levels of torque may Care and questions. distort the sprinkler inlet with conse- quent leakage or impairment of the Maintenance NOTICE sprinkler. The Tyco® Rapid ResponseTM Series The owner must assure that the sprin- Do not attempt to compensate for in- LFII (TY3596) must be maintained klers are not used for hanging of any sufficient adjustment in the Cover and serviced in accordance with the objects and that the sprinklers are only Plate/Retainer Assembly by under-or following instructions: cleaned by means of gently dusting over-tightening the Sprinkler. Read- with a feather duster; otherwise, non- just the position of the sprinkler fitting NOTICE operation in the event of a fire or Thad- to suit. vertent operation may result. Absence of a Cover Plate may delay the Step 1. The sprinkler must only be sprinkler operation in a fire situation. Automatic sprinkler systems should be installed in the pendent position and inspected,tested,and maintained by a with the centerline of the sprinkler When properly installed, there is a ualified Ins ection Service in accor- perpendicular to the mounting nominal 1/8 inch (3,2 mm)air gap be- q p surface. tween the lip of the Cover Plate and dance with local requirements and/or the ceiling, as shown in Figure 3. This national codes. Step 2.Remove the Protective Cap. air gap is necessary for proper oper- Step 3. With pipe thread sealant ation of the sprinkler by allowing heat applied to the pipe threads, and using flow from a fire to pass below and the W-Type 18 Wrench shown in Figure above the Cover Plate to help assure 2, install and tighten the Sprinkler/ appropriate release of the Cover Plate Support Cup Assembly into the fitting. in a fire situation. If the ceiling is to be The W-Type 18 Wrench will accept a repainted after the installation of the 1/2 inch ratchet drive. Sprinkler, care must be exercised to Step 4. Replace the Protective Cap ensure that the new paint does NOT by pushing it upwards until it bottoms seal off any of the air gap. out against the Support Cup. The Factory painted Cover Plates MUST Protective Cap helps prevent damage NOT be repainted. They should be re- to the Deflector and Guide Pins during placed, if necessary, by factory paint- ceiling installation and/or during ed units. Non-factory applied paint application of the finish coating of the may adversely delay or prevent sprin- ceiling. It may also be used to locate kler operation in the event of a fire. the center of the clearance hole by Do not pull the Cover Plate relative to gently pushing the ceiling material the Enclosure. Separation may result. against the center point of the Cap. Before closing a fire protection system NOTICE main control valve for maintenance work on the fire protection system As long as the protective Cap remains which it controls, permission to shut in place, the system is considered to down the affected fire protection sys- be "Out Of Service". tern must be obtained from the prop- Step 5. After the ceiling has been er authorities and all personnel who completed with the 2-1/2 inch(63 mm) may be affected by this action must be diameter clearance hole and in prep- notified. aration for installing the Cover Plate Sprinklers which are found to be leak- Assembly, remove and discard the ing or exhibiting visible signs of corro- Protective Cap, and verify that the De- sion must be replaced. flector moves up and down freely. Automatic sprinklers must never be If the Sprinkler has been damaged and painted, plated, coated, or otherwise the Deflector does not move up and altered after leaving the factory. Modi- down freely, replace the entire Sprin- fled or over heated sprinklers must be kler assembly.Do not attempt to mod- replaced. TFP442 Page 5 of 6 Limited Ordering Warranty Procedure Products manufactured by Tyco Fire When placing an order, indicate the & Building Products (TFBP) are war- full product name. Contact your local ranted solely to the original Buyer for distributor for availability. ten(10)years against defects in mate- Sprinkler Assembly: rial and workmanship when paid for Series LFII (TY3596), K=4.9, Resi- and properly installed and maintained dential Concealed Pendent Sprin- under normal use and service. This kler without Cover Plate Assembly, warranty will expire ten(10)years from P/N 51-112-1-160. date of shipment by TFBP. No warran- ty is given for products or components Cover Plate Assembly: manufactured by companies not af- Cover Plate Assembly having a(spec- filiated by ownership with TFBP or for ify) finish for the Series LFII (TY3596), products and components which have K=4.9,Residential Concealed Pendent been subject to misuse, improper in- Sprinkler, P/N (specify). stallation,corrosion,or which have not Chrome P/N 56-122-9-135 been installed,maintained,modified or signal White(a) repaired in accordance with applicable (RAL 9003) P/N 56-122-4-135 Standards of the National Fire Protec- Pure White(b) tion Association, and/or the standards (RAL 9010) P/N 56-122-3-135 of any other Authorities Having Juris- Custom P/N 56-122-X-135 diction. Materials found by TFBP to be defective shall be either repaired or re- (a) EastPrevern ly known Hemisphereae salesBrlest White. placed, at TFBP's sole option. TFBP (b) Eastern only. neither assumes, nor authorizes any Sprinkler Wrench: person to assume for it, any other ob- Specify: W-Type 18 Sprinkler Wrench, ligation in connection with the sale of P/N 56-000-1-265. products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect,special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 6 of 6 TFP442 ©2008 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446 Jenn Sandvig From: Tom Marshall Sent: Friday, September 09, 2016 1:00 PM To: Jenn Sandvig Subject: Resume for Jet Industries • Jenn, Can you go get the jet resume for job qualification from Brad and get a copy to Terry for a new job in Eugene? Thank you! Sent from my iPhone SO1r4rae-11" INOLiB7 IEB ELECTRICAL HVAC MAINTENANCE PLUMBING TIRE PROTECTION Bcamant NG COMMUNICATIONS `Solutions for a streamlined project." Fire A Division of Jet Industries Tom Marshall Vice President 1935 Silverton Rd. Tel: 503-363-2334 Salem,OR 97301 Fax: 503-364-2204 wwwjetindustries.net Mobile:503-302-5730 1 tqco I Fire & Buildinca► Products rapid response HOME FIRE SPRINKLER SYSTEM Technical Services:Tel: (800)381-9312/Fax: (800)791-5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description Technical Tyco® CPVC Pipe and Fittings pro- Data duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively Sizes •tt for use in wet pipe automatic fire sprin- 3/4"to 3" kler systems. The Tyco CPVC Pipe Maximum Working Pressure and Fittings are produced from Blaze- 175 psi 4,1.` ,w,` ` Master® CPVC compound that is a specially developed thermoplastic Approvalsf. compound composed of post chlorin- UL, FM, C-UL, NSF, LPCB, MEA, and ated polyvinyl chloride (CPVC) resin the City of Los Angeles. (Refer to In- 7 , and state of the art additives. Tyco stallation Handbook IH-1900 dated CPVC Pipe and Fittings are easier to June 2008 for exact listing/approval install than traditional steel pipe sys- information.) tems, and at the same time, provide Manufacture Source superior heat resistance and strength U.S.A. as compared to traditional CPVC and PVC piping materials used in the Material plumbing trade. Various adapters are • Pipe:ASTM F442, SDR 13.5 available to connect CPVC pipe to me- tallic piping. All female pipe thread • Fittings: ASTM F438 (Sch. 40) and adapters have brass inserts for dura- ASTM F439(Sch.80),ASTM F1970 bility. Grooved adapters connect di- Color rectly to grooved end valves and me- Orange tallic pipe, with flexible grooved end couplings. NOTICE Tyco® CPVC Pipe and Fittings pro- duced with BlazeMaster®CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. BlazeMaster®is a registered trademark of The Lubrizol Corporation Page 1 of 2 JUNE, 2008 TFP1915 Page 2 of 2 TFP1915 Installation Limited Tyco® CPVC Pipe and Fittings pro- Warranty duced by Tyco Fire & Building Prod- ucts (TFBP) are to be installed in Products manufactured by Tyco Fire& accordance with Installation Hand- Building Products (TFBP) are war- book IH-1900 dated June 2008. ranted solely to the original Buyer for ten(10)years against defects in mate- Care and rial and workmanship when paid for and properly installed and maintained under normal use and service. This Maintenance warranty will expire ten (10) years from date of shipment by TFBP. No The owner is responsible for the in- warranty is given for products or com- spection, testing, and maintenance of ponents manufactured by companies their fire protection system and de- not affiliated by ownership with TFBP vices in compliance with this docu- or for products and components which ment, as well as with the applicable have been subject to misuse,improper standards of the National Fire Protec- installation, corrosion, or which have tion Association (e.g., NFPA 25), in not been installed, maintained, modi- addition to the standards of any fied or repaired in accordance with ap- authority having jurisdiction. The in- plicable Standards of the National Fire stalling contractor or product manufac- Protection Association, and/or the turer should be contacted relative to standards of any other Authorities any questions. Having Jurisdiction. Materials found Automatic sprinkler systems should be by TFBP to be defective shall be either inspected,tested,and maintained by a repaired or replaced, at TFBP's sole qualified Inspection Service in accord- option. TFBP neither assumes, nor ance with local requirements and/or authorizes any person to assume for it, national codes. any other obligation in connection with the sale of products or parts of prod- NOTICE ucts.TFBP shall not be responsible for sprinkler system design errors or inac- Before closing a fire protection system curate or incomplete information repre- controlsup- valve for inspection or mainte- plied by Buyer or Buyer's nance work on the fire protection sys- sentatives. tem that it controls,permission to shut In no event shall TFBP be liable, in down the affected fire protection sys- contract, tort, strict liability or under tern must first be obtained from the any other legal theory, for incidental, proper authorities and all personnel indirect,special or consequential dam- who may be affected by this action ages, including but not limited to labor must be notified. charges, regardless of whether TFBP was informed about the possibility of After placing a fire protection system such damages, and in no event shall in service,notify the proper authorities TFBP's liability exceed an amount and advise those responsible formoni- equal to the sales price. toring proprietary and/or central sta- The foregoing warranty is made in lieu tion alarms. of any and all other warranties. ex- press or implied. including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products,materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law.The invalidity,in whole or part, of any portion of this warranty will not affect the remainder. ©2008 TYCO FIRE&BUILDING PRODUCTS,451 North Cannon Avenue,Lansdale,Pennsylvania 19446