Loading...
Specifications (27) 6ta,02a s-- 602 1t../0..skt_ S 2...,- i 117-f, Du, 2 32_1115 4,, , ;111n) 'TILDINC D1VIlill,)1' STRUCTURAL CALCULATIONS PREPARED FOR: GODIVA CHOCOLATIER WASHINGTON SQUARE MALL SPACE B04 9585 SW WASHINGTON SQUARE ROAD PORTLAND, OR TOTAL NO. SHEETS (NOT INCLUDING THIS SHEET): 9 DATE: 12/15/2015 f , virce, -, :, 44 .,• •fr C ..?„ • ir i OREGON 06, / —EPH k2f- --).„ c( (( LEWIS ENGINEERING Structural Calculations CONSULTING STRUCTURAL ENGINEERS Godiva Chocolatier 3260 W.HENDERSON RD.SUITE 10 Washington Sq.Mall COLUMBUS,OH 43220 PORTLAND,OR Ph:614-326-2806 Fax:614-326-2805 Design Code: Oregon Structural Specialty Code Referenced Standards ESR-1271 Self-drilling screws ESR-1166P Metal studs ESR-3027 HILTI KWIK HUS-EZ Steel Screw Anchors Wall Mounted Shelving on Standards Design Loads Each section of shelf is designed to carry 20 lbs per level. Seismic: Ss = 0.983 S1 = 0.422 Site Class = D (assumed) Fa = 1.1 Fv= 1.6 SDS = (2/3)FaSs = 0.725 SD1 = (2/3)F„S1 = 0.444 Occupancy Category = II Seismic Design Category = D Structural element: Interior non-structural walls ap = 1.0 Rp = 2.5 1p = 1.5 z = 12' h = 20' .4a S° W i FP = R P \1+2—/ _.26 Wp p1l Fp (max) = 1.6SDs IpWp = 1.16Wp O.K. Fp (min.) = .3 SDs 1p Wp = .22 Wp O.K. Standard Attachment to Furring Standards are spaced @ 2'-0" o.c. horizontally. Standards attach to 1x6 furring strips spaced at 2'-0" o.c. vertically. Each furring strip supports 2 rows of shelving. Each section of shelf is designed to carry 40 lbs per level. Standards: %" wide x1/2" deep x 12 ga. Furring: 1 x 6 DF (3/4" actual thickness, G = .46) Screw: #10 x 13/" wood screw (D = .190", Dr = .152") w a z = (20 lbs)(5 shelves max.) = 100 lbs per furring strip w = (.26)(100 lbs) = 26 lbs per furring strip z . z z«= (z2 +w2)' 103 lbs a = tan-1(w/z) 32.9° « = Allowable screw values: p = 3/4" (thread penetration in base wood) CD = 1.6 (seismic) Z = 116 lbs (from NDS yield line equations) Wp= (2850)G2Dp = 86 lb (NDS withdrawal equation) Z' = ZCD = (116 lbs)(1.6) = 186 lbs W'p = WpCD = (86 lb/in)(1")(1.6) = 138 lbs W pZ' Z o pcos2a+Z'sin2a = 179 lb > 103 lb (NDS comb lat. & withdrawal equation) OK - 1 - LEWIS ENGINEERING Structural Calculations CONSULTING STRUCTURAL ENGINEERS Godiva Chocolatier 3260 W.HENDERSON RD.SUITE 10 Washington Sq.Mall COLUMBUS,OH 43220 PORTLAND,OR Ph:614-326-2806 Fax:614-326-2805 Wall Mounted Shelving on Standards (cont'd) Attachment of furring to studs—(3)#10 SDS (a_each stud V = (100 lbs)(16"/24") = 67 lb T = (26 lbs)(16"/24") = 17 lb (3) #10 TEK screws in 20 ga. studs: Va„ow = (3)(164 lb) = 492 lbs OK Tallow = (3)(77 lbs) = 231 lbs OK (ESR-1271) Chrome Wire Shelving Foot Plate Anchorage Concrete Anchors—(3) 1/4"o Hilti KWIK HUS-EZ Screw Anchors Assume normal-weight concrete: f'c = 2500 psi Anchor Embedment = 1 5/8" Plat = V = 111 Ib, Pup = T = 297 lb (from finite element analysis) Pu= 178 lbs., Tu = 475 lbs. (factored loads) From attached computer output, 1/4” dia. Hilti Kwik HUS-EZ's O.K. Check Concrete Slab Puncture Pdown = 299 lb Vu = (1.7) 299 lb = 508 lb Slab t =4", f'c = 2500 psi (min.) Base Plate Dimensions: B1 = 3.5", B2= 1.75" Concrete shear area = 2(B1 + B2)t =42 in2 goVn=(.85)2Vf'cAc= 3570 lb O.K. - 2 - i ■,,; 1,; www.hilti.us Profis Anchor 2.6.0 Company: Page: 1 Specifier: Project: Address: Sub-Project I Pos. No.: Phone I Fax: I Date: 11/28/2015 E-Mail: Specifier's comments: • 1 Input data Anchor type and diameter: KWIK HUS-EZ(KH-EZ)1/4(1 5/8) twito " � Effective embedment depth: het=1.180 in., hnom=1.625 in. Material: Carbon Steel - Evaluation Service Report: ESR-3027 Issued I Valid: 6/1/2014 112/1/2015 Proof: Design method ACI 318/AC193 Stand-off installation: eb=0.000 in.(no stand-off);t=0.500 in. Anchor plate: Ix x ly x t=4.375 in.x 3.845 in.x 0.500 in.;(Recommended plate thickness:not calculated Profile: Round bars(AISC);(L x W x T)=0.063 in.x 0.063 in.x 0.000 in. Base material: cracked concrete,2500,fo'=2500 psi;h=4.000 in. Reinforcement: tension:condition B,shear:condition B; no supplemental splitting reinforcement present edge reinforcement:none or<No.4 bar Seismic loads(cat.C,D, E,or F) no Geometry[in.]&Loading[Ib,in.Ib] Z co co \\\: ° 0 ko ....AP'- \� + �► X Input data and results must be checked for agreement with the existing conditions and for plausibilityl PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan . -.ie www.hilti.us Profis Anchor 2.6.0 Company: Page: 2 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: Date: 11/28/2015 E-Mail: 2 Load case/Resulting anchor forces Load case:Design loads • Anchor reactions[Ib] Tension force:(+Tension,-Compression) /' 3 Anchor Tension force Shear force Shear force x Shear force y 1 153 59 0 59 2 153 59 0 59 3 168 59 0 59 max.concrete compressive strain: -[%o] max.concrete compressive stress: -[psi] 1%.,X Tension resulting tension force in(x/y)=(0.000/0.000): 475[lb] resulting compression force in(x/y)=(0.000/0.000):0[Ib] 01 02 3 Tension load Load N.[lb] Capacity(IA,[Ib] Utilization 13N=Nua/+Nn Status Steel Strength* 168 3679 5 OK Pullout Strength* 168 300 57 OK Concrete Breakout Strength** 475 1071 45 OK *anchor having the highest loading **anchor group(anchors in tension) 3.1 Steel Strength N. =ESR value refer to ICC-ES ESR-3027 4)Nsteei Z Nua ACI 318-08 Eq.(D-1) Variables n Ase,N[in.2] futa[psi] 1 0.05 112540 Calculations Nsa[Ib] 5660 Results Nsa[Ib] 4)steei 4)1\15a[Ib] Nua[Ib] 5660 0.650 3679 168 3.2 Pullout Strength Npn,l =Np,2500(V2500)0 3 refer to ICC-ES ESR-3027 Npn,f,2 Naa ACI 318-08 Eq.(D-1) Variables C[psi] Np,2500[lb] 2500 667 Calculations (fc'/2500)°.3 1.000 Results Npn,4[Ib] (1)concrete Npn t [Ib] N.[Ib] 667 0.450 300 168 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan lb is a registered Trademark of Hilti AG,Schaan I . www.hilti.us Profis Anchor 2.6.0 Company: Page: 3 Specifier: Project: Address: Sub-Project I Pos. No.: Phone I Fax: I Date: 11/28/2015 E-Mail: 3.3 Concrete Breakout Strength Ncbg = erne Wec,N Wed,N Wc,N Wcp,N Nb ACI 318-08 Eq.(D-5) 4 Ncbg 2 Noa ACI 318-08 Eq.(D-1) ANc see ACI 318-08,Part D.5.2.1,Fig.RD.5.2.1(b) ANcO =9 hef ACI 318-08 Eq.(D-6) 1 lifec,N (1 +2 eN S 1.0 ACI 318-08 Eq.(D-9) = 3her Wed,N =0.7+0.3 1Ca,mhineef/5 1.0 ACI 318-08 Eq.(D-11) 5 Wcp N MAX(Camin� Cae J 1.5het1 5 1.0 ACI 318-08 Eq.(D-13) MAX( Cae Nb =kc) hef' ACI 318-08 Eq.(D-7) Variables her[in.] ecl,N[in.] ec2,N[in.] Ca,min[in.] Wc,N 1.180 0.000 0.042 1.000 cac[in.] kc Tc[psi] 2.000 17 1 2500 Calculations AN5[In.2] ANCO[in.2] Wect,N Wec2,N Wed,N Wcp,N Nb[Ib] 28.02 12.53 1.000 0.977 1.000 1.000 1090 Results Ncbg[Ib] 4)concrete 4)Ncbg[lb] Nua[Ib] 2380 0.450 1071 475 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROF IS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan 11.111111114111.1 www.hilti.us Profis Anchor 2.6.0 Company: Page: 4 Specifier: Project: Address: Sub-Project I Pos. No.: Phone I Fax: I Date: 11/28/2015 E-Mail: 4 Shear load Load Vua[Ib] Capacity 4,V„[Ib] Utilization[iv=Vua/(1)Vn Status Steel Strength* 59 929 7 OK Steel failure(with lever arm)* N/A N/A N/A N/A Pryout Strength** 178 1705 11 OK Concrete edge failure in direction** N/A N/A N/A N/A *anchor having the highest loading **anchor group(relevant anchors) - 4.1 Steel Strength Vsa =ESR value refer to ICC-ES ESR-3027 Vsteel Z Vua ACI 318-08 Eq.(D-2) Variables n Ase,v[in.2] futa[psi] 1 0.05 112540 Calculations Vs„[lb] 1548 Results Vsa[lb] 4)steel $Vsa[ib] Vua[lb] 1548 0.600 929 59 4.2 Pryout Strength Vcpg =kcp [(A—)Wec,N Wed,N Wc,N tPcp,N Nb] ACI 318-08 Eq.(D-31) Vcpg 2 Vua ACI 318-08 Eq.(D-2) ANC see ACI 318-08,Part D.5.2.1,Fig. RD.5.2.1(b) ANso =9 hef ACI 318-08 Eq.(D-6) 1 1irec,N = (1 +2 eN l 5 1.0 ACI 318-08 Eq.(D-9) 3 her N/ed,N =0.7+0.3 (Ca,min)5 1.0 ACI 318-08 Eq.(D-11) `1.5het Wcp,N =MAX(Ca min, 1.5hefl 5 1.0 ACI 318-08 Eq.(D-13) `` Cac Cac / Nb =kc Affrchef5 ACI 318-08 Eq.(D-7) Variables kap het[in.] ec,.N[in.] ec2,N[in.] ca,min[in.] 1 1.180 0.000 0.000 tllc,N cac[in.] kc fc[psi] 1.000 2.000 17 1 2500 Calculations ANc[in.2] ANcO[in.2] Wect,N Wec2,N Wed,N tilcp,N Nb[lb] 28.02 12.53 1.000 1.000 1.000 1.000 1090 Results Vopg[Ib] concrete (I)Vcpg[Ib] Vua[Ib] 2436 0.700 1705 178 Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan I www.hilti.us Profis Anchor 2.6.0 Company: Page: 5 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 11/28/2015 E-Mail: 5 Combined tension and shear loads 13N Rv Utilization RN,v[%] Status 0.560 0.104 5/3 41 OK RNV_ RV<-1 ' 6 Warnings • Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered.The anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the existing conditions and for plausibility! • The fixture thickness may not be feasible for the anchor selected.Check the fixture thickness against the anchor length and effective embedment depth. • Condition A applies when supplementary reinforcement is used.The cD factor is increased for non-steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength.Refer to your local standard. • Refer to the manufacturer's product literature for cleaning and installation instructions. • Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard! Fastening meets the design criteria! Input data and results must be checked for agreement with the existing conditions and for plausibility' PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan • 11041161111111. www.hilti.us Profis Anchor 2.6.0 Company: Page: 6 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 11/28/2015 E-Mail: 7 Installation data Anchor plate,steel:- Anchor type and diameter:KWIK HUS-EZ(KH-EZ) 1/4(1 5/8) Profile:Round bars(AISC);0.063 x 0.063 x 0.000 in. Installation torque:216.002 in.lb Hole diameter in the fixture:df=0.375 in. Hole diameter in the base material:0.250 in. Plate thickness(input):0.500 in. Hole depth in the base material: 1.836 in. - Recommended plate thickness:not calculated Minimum thickness of the base material:3.250 in. Cleaning:Manual cleaning of the drilled hole according to instructions for use is required. A 2.188 2.187 • • M 3 N O O O (Ni 00 • �X N N 1 0 2 • CO CO (17 O • 1.000 1.188 1.188 0.999 • • . T i • Coordinates Anchor in. Anchor x y c-x c+x c-y c.y 1 -1.188 -0.708 - - - - 2 1.188 -0.708 - - - - 3 0.000 1.292 - - - - Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Huh AG,Schaan immisret www.hilti.us Profis Anchor 2.6.0 Company: Page: 7 Specifier: Project: Address: Sub-Project I Pos.No.: Phone I Fax: I Date: 11/28/2015 E-Mail: 8 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles,formulas and security regulations in accordance with Hilti's technical directions and operating,mounting and assembly instructions,etc.,that must be strictly complied with by the user. All figures contained therein are average figures,and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. • Therefore,you bear the sole responsibility for the absence of errors,the completeness and the relevance of the data to be put in by you. Moreover,you bear sole responsibility for having the results of the calculation checked and cleared by an expert,particularly with regard to compliance with applicable norms and permits,prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors,the correctness and the relevance of the results or suitability for a specific application. - • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular,you must arrange for the regular backup of programs and data and,if applicable,carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software,you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences,such as the recovery of lost or damaged data or programs,arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor(c)2003-2009 Hilti AG,FL-9494 Schaan -lilti is a registered Trademark of Hilti AG,Schaan