Loading...
Report (2) .. 6 uhf«- %. s3v scv ,✓6-s 4 l1L • ECE DEC 2014iViii)irrift COMcheck Software Version 3.9.4 Interior Lighting Compliance ertificateBUILDINGtin'OF fIGAIC) r 2014 Oregon Energy Efficiency Specialty Code Section 1: Project Information Project Type:Alteration Project Title:ATHLETA Construction Site: Owner/Agent: Designer/Contractor: WASHINTON SQUARE GAP INC DAVIS DICKERSON 9585 SW WASHINGTON SQUARE RD CORPORATE ARCHITECTURE DICKERSON ENGINEERING INC PORTLAND,OR 97223 1 HARRISON ST 8101 NORTH MILWAUKEE AVE SAN FRANCISCO,CA 94105 NILES,IL 60714 847 966 0290 PR@DEI-PE.COM Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Retail:Sales Area(Ceiling Height 12 ft.) 2141 1.5 3212 Allowance:Furniture,clothing,cosmetics highlighting/Fix. ID:TRACK AND 2141(a) 1.4 2997(b) LED TRACK HEADS Common Space Types:Active Storage(Ceiling Height 28 ft.) 587 0.73(d) 429 Common Space Types:Dressing/Locker Room(Ceiling Height 12 ft.) 662 0.52 344 Common Space Types:CorridorfTransition(Ceiling Height 9 ft.) 154 0.41 63 Common Space Types:Restrooms(Ceiling Height 9 ft.) 133 0.82 109 Total Allowed Watts= 7154 (a)Area claimed may exceed total floor area when Retail Merchandise Highlighting allowance(s)are specified. (b) Allowance is(B x C)or the actual wattage of the fixtures given in Section 2,whichever is less. (d) Allowed watts per sq.ft.adjusted for ceiling height. Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp I Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail:Sales Area(2141 sq.ft.) Compact Fluorescent:P106:PENDANT:Spiral 15W:Electronic: 1 3 15 45 Compact Fluorescent:P107:PENDANT:Spiral 15W:Electronic: 1 19 15 285 Track lighting:TRACK AND LED TRACK HEADS:Wattage based on circuit breaker 0 0 4800 4800 capacity(40 amps x 120 volts) Compact Fluorescent copy 2:R100:DOWNLIGHT:Triple 4-pin 32W:Electronic: 1 2 36 72 Common Space Types:Active Storage(587 sq.ft.) Linear Fluorescent:L103:4 FOOT STRIP LTG:48"T8 32W:Premium efficiency: 2 19 56 1064 Compact Fluorescent 7:S105:Other:Electronic: 1 1 13 13 Common Space Types:Dressing/Locker Room(662 sq.ft.) Compact Fluorescent:5110:PENDANT:Spiral 15W:Electronic: 1 7 15 105 Compact Fluorescent:P107:PENDANT:Spiral 15W:Electronic: 1 5 15 75 Linear Fluorescent:R106:LINERAR RECESSED 3 FT:35"T5 21W:Electronic: 1 1 21 21 Linear Fluorescent copy 1:R105:LINERAR RECESSED 4 FT:46"T5 28W:Electronic: 1 5 28 140 Common Space Types:Corridor/Transition(154 sq.ft.) Compact Fluorescent copy 1:R100:DOWNLIGHT:Triple 4-pin 32W:Electronic: 1 4 36 144 Common Space Types:Restrooms(133 sq.ft.) Project Title: ATHLETA Report date: 12/10/14 Data filename: H:\14015.56\4642 Washington OR.cck Page 1 of 3 t Compact Fluorescent:R100:DOWNLIGHT:Triple 4-pin 32W:Electronic: 1 2 36 72 Total Proposed Watts= 6836 Section 4: Requirements Checklist In the following requirements,blank checkboxes identify requirements that the applicant has not acknowledged as being met.Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: • 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage:7154 Proposed Wattage:6836 Complies:YES Mandatory Requirements: ✓ 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: E1-1 ✓ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control, while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east, south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. Exception applies:Retail spaces adjacent to vertical glazing(retail spaces under overhead glazing are not exempt). Plans reference page/section: ✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or are a remote switch that identifies the lights served and indicates their status. Plans reference page/section: E1-1 D 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. Plans reference page/section: ✓ 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Plans reference page/section: E1-1 ✓ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: E9-3 ✓ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1)controlling(dimming or multi-level switching)all luminaires;or 2)dual switching of alternate rows of luminaires,altemate luminaires,or alternate lamps;or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Plans reference page/section: E9-3 ✓ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic control device shall function on either: 1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor;or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or 3)a signal from another control or alarm system that indicates the area is unoccupied. Plans reference page/section: E9-3 j 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: E9-3 11 An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Plans reference page/section: E1-1 Project Title:ATHLETA Report date: 12/10/14 Data filename: H:\14015.56\4642 Washington OR.cck Page 2 of 3 ✓ 12.Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: E1-1 ✓ 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that:1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2,000 square feet. Exception applies:In malls and arcades,auditoriums,single-tenant retail spaces,industrial facilities and arenas,the area controlled shall not exceed 20,000 square feet. Plans reference page/section: ✓ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that tums off all loads for at least 24 hours,then resumes the normally scheduled operation. Exception applies:Retail stores and associated malls,restaurants,grocery stores,places of religious worship,theaters and exterior lighting zones. Plans reference page/section: ✓ 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch.Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section: E9-3 ✓ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet center-to-center of each other. 2.Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted within 1 foot edge-to-edge of each other. Plans reference page/section: E1-1 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Plans reference page/section: ✓ 18.Each dwelling unit in a building is metered separately. Plans reference page/section: E9-0 Interior Lighting PASSES Section 5: Compliance Statement Compliance Statement: The proposed lighting design repre -nted in this .. umen s consistent wi e b ilding plans,specifications and other calculations submitted with this permit application.T e proposed lightin. sy em has been designer lo meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck V sion 3. .4 and to com.l with the mandatory req Irements in the Requirements Checklist. DAVIS DICKERSON P.E. 12/11/2014 Name-Title ignatur- Date Project Title: ATHLETA Report date: 12/10/14 Data filename: H:\14015.56\4642 Washington OR.cck Page 3 of 3