Report (5) . Genes Deck �5� /6- —�0/ 7 1-26-16
: ey�Be r
r / 1/ �l 4 s w // .� /9l g:�2of 1
CS Beam 4.1126.1
lanBeamEngine 4.11.26.1
Materials Database 1516
Member Data
Description: RBI Member Type: Girder Application: Roof
Ridge Beam Top Lateral Bracing: Continuous Slope: 0.00/ 12 '.41",
Bottom Lateral Bracing: Continuous ww 4 ,, y
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC a `,, ,,:-
Snow Load: 25 PLF Deflection Criteria: L/240 live, L/180 total . PO ,„.,
Dead Load: 15 PLF Deck Connection: Nailed Member Weight: , . v. Jo
Filename: RBI c5( i, t
Other Loads
Type Trib. Other Dead
(Description) Side Begin End Width Start End Start End Category
Additional Uniform(PLF) Top 0' 0.00" 16' 0.00" 288 173 Snow
16 0 0
7 1600 ®/
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 4000# --
2 16' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 4000# --
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Snow Dead
1 2436# 1565#
2 2436# 1565#
Design spans
15' 6.750"
Product: 5 1/2 x 10 1/2 Rosboro Glulam Arch 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 15564.# 23244.# 66% 8' Total Load D+S
Shear 3551.# 11733.# 30% 0.23' Total Load D+S
Max.Reaction 4000.# 12031.# 33% 16' Total Load D+S
TL Deflection 0.7104" 1.0375" L/262 8' Total Load D+S
LL Deflection 0.4325" 0.7781" L/431 8' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
All product names are trademarks of their respective owners
Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED.
**Passing is defined as when the member,fioorjoist,beam or girderr shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.
The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications.
i Genes Deck 1-18-16
8:23am
loft
CS Beam 4.11.26.1
lanBeamEngine 4.1126.1
Materials Database 1516
Member Data
Description:RB2 Member Type: Girder Application: Roof
Roof Beam Top Lateral Bracing: Continuous Slope: 0.00/ 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Snow Load: 25 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 15 PLF Deck Connection: Nailed Member Weight: 13.1 PLF
Filename: RB2
Other Loads
Type Trib. Other Dead
(Description) Side Begin End Width Start End Start End Category
Additional Uniform(PLF) Top 0' 0.00" 16' 0.00" 144 87 Snow
r
mss•w' .>.,,:dd,. .. -,�' ,,.�'.,� :. ,s.�, ';,�„ .,
1600
p
16 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 2211# --
2 16' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 2211# --
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Snow Dead
1 1315# 896#
2 1315# 896#
Design spans
15' 6.750"
Product: 5 1/2 x 10 1/2 Rosboro Glulam Arch 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 8601.# 23244.# 37% 8' Total Load D+S
Shear 1962.# 11733.# 16% 15' Total Load D+S
Max.Reaction 2211.# 12031.# 18% 0' Total Load D+S
TL Deflection 0.3926" 1.0375" L/475 8' Total Load D+S
LL Deflection 0.2335" 0.7781" L/799 8' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
All product names are trademarks of their respective owners
Copyright(C)2013 by Simpson Strong-Tie Companylnc.ALL RIGHTS RESERVED.
**Passing is defined as when the member,floorjoist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.
The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications.
Genes Deck 1-18-16
r
K@y e l " 8:22am
1of1
CS Beam 4.11.26.1
lanBeamEngine 4.11.26.1
Materials Database 1516
Member Data
Description: RB3 Member Type: Girder Application: Roof
Ridge Support Beam Top Lateral Bracing: Continuous Slope: 0.00/ 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Snow Load: 25 PLF Deflection Criteria: L/240 live, U180 total
Dead Load: 15 PLF Deck Connection: Nailed Member Weight: 16.0 PLF
Filename: RB3
Other Loads
Type Trib. Other Dead
(Description) Side Begin End Width Start End Start End Category
Point(LBS) Top 11' 6.00" 2436 1565 Snow
2300
7 2300
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 2632# --
2 23' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 2632# --
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Snow Dead
1 1500# 1132#
2 1500# 1132#
Design spans
22' 6.750"
Product: 5 1/2 x 12 Rosboro Glulam Arch 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 26132.# 29931.# 87% 11.5' Total Load D+S
Shear 2576.# 13409.# 19% 22.64' Total Load D+S
Max.Reaction 2632.# 12031.# 21% 0' Total Load D+S
TL Deflection 1.3893" 1.5042" L/194 11.5' Total Load D+S
LL Deflection 0.8087" 1.1281" L/334 11.5' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
All product names are trademarks of their respective owners
Copyright(C)2013 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED.
"Passing is defined as when the member,floor joist,beam orgirder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.
The design must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications.
1 Genes Deck 1-26-16
Keyte 8:58am
1of1
CS Beam 4.11.26.1
kmBeamEngine 4.11.26.1
Materials Database 1516
Member Data
Description: RB4 Member Type: Girder Application: Roof
Header over Master Slider Top Lateral Bracing: Continuous Slope: 0.00/ 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Snow Load: 25 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 15 PLF Deck Connection: Nailed Member Weight: 9.4 PLF
Filename: RB4
Other Loads
Type Trib. Other Dead
(Description) Side Begin End Width Start End Start End Category
Point(LBS) Top 4' 0.00" 1375 825 Snow
iimmimmimmiimmmimmip
/ /
O 8 0 0
/ soo �/
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 1287# --
2 8' 0.000" Wall DFL Plate(625psi) 3.500" 1.500" 1287# --
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Snow Dead
1 782# 505#
2 782# 505#
Design spans
7' 6.750"
Product: Douglas Fir-Larch #2 4 x 12 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 4513.# 7004.# 64% 4' Total Load D+S
Shear 1240.# 5434.# 22% 0.23' Total Load D+S
Max.Reaction 1287.# 7656.# 16% 0' Total Load D+S
LL Deflection 0.0350" 0.3781" L/999+ 4' Total Load S
TL Deflection 0.0570" 0.5042" L/999+ 4' Total Load D+S
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
This member has been designed in accordance with NDS 2005
All product names are trademarks of their respective owners
Copyright(C)2013 by Simpson Strong-Tie Companylnc.ALL RIGHTS RESERVED.
"Passing is defined as when the member,floorjoist,beam orgirder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.
The design must be reviewed bya qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturers specifications.