Report
ysa-0/6,,-6)0 /y 4 fir% t 11.111 'SIRS, CORPORATION TABLE OF CONTENTS Fire Alarm Notifier NFW2-100 Addressable Fire Control Panel Notifier FDU-80 Annunciator Notifier FCPS-24S6 Remote Power Supply Notifier NOT-BG12LX Addressable Pull Station Notifier NP-100 Addressable Smoke Detector Notifier NH-100 Addressable Heat Detector Notifier B210LP Detector Base (Smoke & Heat) Notifier NC-100R Addressable Relay Module 1 Notifier NC-100 Addressable Control Module Notifier NMM-100P Addressable Mini-Monitoring Module System Sensor P2W, SW Horn Strobe, Strobe System Sensor HW-LF, P2WH-LF Low Frequency Horn, Horn Strobes System Sensor P2WK Weatherproof Horn Strobe DN-60602:A1 FireWarden-100-2(E) Rev 3 NOTIFIER® Intelligent Addressable FACP by Honeywell Addressable Are Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3 (NFW2-100)with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT(Digital Alarm Communicator/Transmitter) all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled. When construction is completed,the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS,and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status(alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public • Remote site or local USB port upload/download, using PS- switched telephone network. It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows®XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software . Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board.This permits easy typing of • ANN BUS for connection to following optional modules(cannot address labels and other programming information. be used if ACS annunciators are used): Version 5.0 firmware supports the following: Primary and Sec- –N-ANN-80(-W)Remote LCD Annunciator ondary ANN-bus devices,NP-A100,USB port,NAC circuit diag- –N-ANN-I/O LED Driver nostics, a new report has been added to the walk-test that lists –N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone –N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- –N-ANN-LED Annunciator Module table Drill(non-latching). –N-ANN-RLED Annunciator Module alarms only The FireWatch Series Internet monitoring modules IPDACT-2 –ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele • ACS&Terminal-mode Annunciators: phone lines. Although not required, the secondary telephone –ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term `FireWarden-100-2" –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWarden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-100E as well. cuit board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point • Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E: Same as NFW2-100,except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NA CS): tion. • Four onboard NACs with additional NAC capability using out- 4XTM Reverse Polarity Transmitter Module: Provides super- put control modules (NC-100). The four Class B NACs can and t output for local energy municipal box transmitter, alarm, be converted to four Class A NACs with optional ZNAC-92 and trouble. converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y (Class B) NAC circuits to four(4) Style Z(Class A)cir- cuits. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. PS Tools: Programming software for Windows®based PC • Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. • 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE:Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram(learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than • Continuous fire protection during online programming at the 18AH. front panel. BAT Series: Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable; required for printer or for local upload/download program- able on www.magni-fire.com).Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT-2/2UD, IPDACT Internet MonitoringModule: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- netLED INDICATORS internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IP.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-100R: Addressable relay module containing two isolated N-ANN-RLED: Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connection for a serial or parallel printer. (See DN-7103.) on a CHS-6 chassis in a BB-25. N-ANN-I/O: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional). Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation.Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-ISO(DN-6994),NP-100 series custom graphic annunciators. (DN-6995),NI-100(DN-6996), NH-100 series(DN-6997),ND-100 series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator: 80-char- NDM-100/NZM-100 (DN-6999), NC-100/NC-10OR (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100: Fast-response,low-profile heat detector. NH-100R: Fast-response,low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 FireWarden-100-2 Rev 3 f Fire Alarm Control/ _ `, ANN-BUS Communicator or ANN-BUS DEVICES EIA-485 I N-ANN-80,N-ANN-LED, in ACS mode III' \1 i I it N-ANN-S/PG,N-ANN-I/O (two wires) • � ' • �E r_i^ r"'' £ a SMOKE DETECTORS NP-100,NP-100T, 24 VDC � .x NI-100,NP-A100 I Ir .1 I Optional mo oim 4 REVERSE -o UM POLARITY/ HEAT DETECTORS MIEN CMNH-100,NH-100R,NH-100H MIv EMICITY BOX M0 0= OUTPUT M_0.: ANNUNCIATORS 1 / I I 1 I`II' I`II' Jr (4XTM) —► I1 ^'� ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS NOTE:System can use (optional,order ACM-8R) ND-100,ND-100R,DNR either ANN-BUS devices OR ACS-mode annunciators. They cannot be used — ► l• °n® simultaneously. NACs(Notification — Appliance Circuits) _ _' ► BELLS,SIGNALS,STROBES o - MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into p®BBEnB the motherboard ® ► mil ► 1 1111 /� L`f, EIAD ADDRESSABLE B LE MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They fi,d.2 a cannot be used simultaneously. _._-_ EIA-485 24 VDC ► INTERFACE , .1 (four wires) MINI-MONITOR ► NMM-100P � � � 001::t j . • FIRE FDU-80 Up to 6,000 ft.(1825.8 m) ► between each FDU-80 in O the EIA-485 loop,and between PULL STATION each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 DN-60602:A1•12/07/2010—Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring(TR-CE- • Intelligent Signalling Line Circuits 1 B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Addressable device capacity 198 Shipping Specifications • Programmable software zones 99 • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • ANN-bus devices 16 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Electrical Specifications Temperature and Humidity Ranges AC Power: FireWarden 100 2 Rev 3: 120 VAC, 60 Hz, 3.0 This system meets NFPA requirements for operation at 0 — 49°C/32—120°F and at a relative humidity 93%±2%RH(non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C± 2°C (90°F±3°F). However, the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120, and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y(Class B) for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B)or with an optional ZNAC-92 module converts to four Style Z(Class A) NACs. Maximum signaling current per circuit: —LOCAL (Automatic, Manual, Waterflow and Sprinkler 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 Supervisory). UL listed)for Style Y(Class B)NAC. Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed corn- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory)(Where a DACT is not accepted,the Two Programmable Relays and One Fixed Trouble Relay: Contact rating:2.0 amps @ 30 VDC (resistive),0.5 amps @ 30 alarm,trouble and supervisory relays may be connected to VAC(resistive). Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of Special Application Non-resettable Power (24 VDC Nomi- alarm and trouble,4XTM is required.) nal):Jumper selectable(JP4)for conversion to resettable power —PROPRIETARY (Automatic, Manual, Waterflow and Sprin- output. Up to 1.0 amp total DC current available from each out kler Supervisory). put.Power limited. —CENTRAL STATION (Automatic, Manual, Waterflow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. —OT,PSDN(Other Technologies, Packet switched Data Net Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel. In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed:S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and ExcederTM is a trademark of Cooper Notification. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F I E We cannot cover all specific applications or anticipate all requirements. ENiINEEEINi&MAMMIES All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 DN-6820:B•D-123 FDU-80 80 Character Liquid Crystal Display ® NOTIFIER® by Honeywell Annunciators General The FDU-80 is a compact, cost-effective,80-character, backlit -e* „ LCD remote Fire Annunciator for use with the NOTIFIER Fire- _ ,i y Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels(FACPs).The FDU-80 mimics the display of the control y *p. • ,, . panel and displays complete system point status information Up to 32 FDU-80s may be connected onto the EIA-485 termi- — °~ nal port of each FACP.The FDU-80 requires no programming, ° ¢ which saves time during system commissioning. Features • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. $y'71 #r. s , • Control switches for System Acknowledge, Signal Silence, ` _ �£ Drill and Reset with enable key. 6820k198 P9 • System status LEDs for Power,Alarm,Trouble,Supervisory and Alarm Silenced. • No programming necessary—FDU-80 connects to the ter- minal porton the FACP. FDU-80:80 character, backlit,LCD Fire Annunciator with con • Displays device type identifiers,individual point alarm,trou- ble or supervisory,zone and custom alpha labels. switch lock. • Time-and-date display field. FDU-80C: ULC listed version;see DN 60573 for details. 10103:Three gang electrical box,minimum 2.188”(5.556 cm) • Aesthetically pleasing design. • May be powered from the host FACP or by remote power deep,for semi flush mount applications. SBB-3: Three gang surface backbox for surface mount appli- cations. Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases,certain modules or applications supply(requires 24 VDC). • Up to 32 FDU-80 annunciators per FACP. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet(1828.8 m) from the FACP. • Local piezo sounder with alarm and trouble resound. • Semi-flush mounts to 2.188" (5.556 cm) minimum deep, may not be listed by certain approval agencies, or listing may three gang electrical box (NOTIFIER PN 10103) or three be in process.Consult factory for latest listing status.• UL Listed:S635 gangable electrical switchbox. • Surface-mounts to NOTIFIER PN SBB-3 surface backbox. • MEA Listed:245-00-E Operation • FDNY:COA#6038 • CSFM:7120-0028:209 The FDU-80 annunciator provides the FACP with point annun- • FM Approved ciation with full display text on an 80-character LCD display. NOTE:For ULC/fisted version,see DN-60573. The FDU-80 also provides an array of LEDs to indicate system status,and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:B•05/17/2010—Page 1 of 2 NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. } We try to keep our product information up-to-date and accurate. * We cannot cover all specific applications or anticipate all requirements. Ft CEEop P pp EN6INEERIN6&MANINIO1N6 All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6820:8•05/17/2010 DN-6927:A2 FCPS-24S6(C/E) & FCPS- 24S8(C/E) NOTIFIER 6- & 8-Amp 24-Volt by Honeywell Remote Power Su• .lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S61- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries.The FCPS-24S6/-2458 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B(Style Y)or Class A(Style Z, with ZNAC-4 _ option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to Wheelock,or Gentex"Commander2"appliances. 18 AH batteries.Cabinet capable of housing 7.0 AH batter- • Operates as a "sync-follower" or as a "sync-generator" ies. (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- • Contains two fully-isolated input/control circuits - triggered tions requiring larger batteries. from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 nently"ON"(stand-alone mode). AWG(3.1 mm2)wire. • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module)NACs. Specifications • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- • Compatible with coded inputs;signals passed through. tion. • Optional power-supervision relay(EOLR-1). Control Input Circuit: • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 non-resettable,or a mix of two and two. -16 V). • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. Bring four wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA system peripherals requiring regulated/filtered power. maximum. • Power-limiting technology meets UL power-limiting require- ments. Output Circuits: • Form-C normally-closed trouble relay. • +24 VDC filtered, regulated. • Fully supervised power supply, battery,and NACs. • 3.0 A maximum for any one circuit. • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S6: 4.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- —FCPS-24S8: 6.0 A maximum. lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): cuit(including unfiltered and unregulated NAC power). —FCPS-24S6: 6.0 A maximum. • Requires input trigger voltage of 9-32 VDC. —FCPS-24S8: 8.0 A maximum. • Self-contained in compact, locking cabinet- 15"H x 14.5"W Secondary Power(Battery)Charging Circuit: x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Supports lead-acid batteries only. DN-6927:A2•5/17/13—Page 1 of 2 • Float-charge voltage: 27.6 VDC. Standards and Codes • Maximum current charge: 1.5 A. The FCPS-24S6 and FCPS-24S8 comply with the following • Maximum battery capacity: 18 AH. standards: Applications • NFPA 72 National Fire Alarm Code. • UL 864 Standard for Control Units for Fire Alarm Systems Example 1: Expand notification appliance power an additional (NAC expander mode). 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four • UL 1481 Power Supplies for Fire Alarm Systems. Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example,the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation Agency Listings and Approvals occurs. Trouble conditions on the FCPS are sensed by the These listings and approvals apply to the modules specified in FACP through the notification appliance circuit. this document. In some cases,certain modules or applications Example 2: Use the FCPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A be in process.Consult factory for latest listing status. (FCPS-24S8). Both resettable and non-resettable power • UL Listed: S635,S674 options are available. Resettable outputs are created by con- • ULC Listed:S635(FCPS-24S6C&FCPS-24S8C) necting the resettable output from the FACP to one or both of the FCPS inputs. • CSFM Approved: 7315-0028:225 • Example 3: Use addressable control modules to activate the MEA: 299-02-E FCPS instead of activating it through the FACP notification • FM Approved appliance circuits.This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding Ordering Information system architecture in various applications. FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. For example, an addressable control module is used to acti- Includes main printed circuit board, transformers, enclosure vete the FCPS,and an addressable monitor module is used to (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and sense FCPS trouble conditions. Local auxiliary power output installation instructions. from the FCPS provides power to the addressable control FCPS-24S6C: Same as above, ULC-listed. module. *NOTE:Addressable FACPs are capable of locating control and FCPS-24S6R: Same as FCPS 24S6 with red enclosure. monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure Sync Follower/Generator Note (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installation instructions. In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Strobes accomplish this by monitoring very short timing pulses Includes main printed circuit board, transformers, enclosure on the NAC power which are created by the FACP. When (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installed at the end of a NAC wire run, the FCPS-24S6/-24S8 installation instructions. can track (i.e. "follow") the strobe synchronization timing FCPS-24S8C Same as above,ULC-listed. pulses on the existing NAC wire run.This maintains the overall system flash timing of the additional strobes attaches to the FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. When the FCPS-24S6/-24S8 is configured(via DIP switch set- Includes main printed circuit board, transformers, enclosure tings) as a"sync follower,"the FCPS's NAC outputs track the (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and strobe synchronization pulses present at the FCPS's sync installation instructions. input terminal.The pulses originate from an upstream FACP or ZNAC-4: Class A(Style Y)NAC option module. other power supply. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-24S6/-2458 are configured (via DIP switch smoke detector power. settings) as a "sync generator," the FCPS's sync input termi- BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT nals are not used. Rather, the FCPS is the originator of the Series data sheet DN-6933). strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator"mode,the sync type(System Sensor, Whee- lock,or Gentex)is selectable via DIP switch settings. System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. "« We try to keep our product information up-to-date and accurate. ;*** CERTF E O We cannot cover all specific applications or anticipate all requirements. ENGINEERING R MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6927:A2•5/17/13 DN-7001:D•Al-380 NOT-BG 12LX 0NOT 1 F 1 E R° Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General -:r r The Notifier NOT-BG12LX is a state-of-the-art, dual-action .b$: (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series v intelligent control panels,and the NSP-25 panel. Because the ,, ' NOT-BG 12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Pk 4 Features ir PULL Do ` - • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. ` i • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to �it�Tt�s € SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. - maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz. (272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot For use indoors in a dry location be restored to normal except by use of a key.An operated sta- • tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi-flush mounting on matching backbox SB 10 or SB-I/O;or semi flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single gang, double gang, or 4"(10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-I/O:Surface backbox; plastic. BG12TR:Optional trim ring. 17021:Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ..******** C E R T F E We cannot cover all specific applications or anticipate all requirements. M lNEHINE&MNIIFACT1AINE All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 DN-6995:C•Al-320 NP-100(A) Series NOTIFIER® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series(FireWarden-100-2 and Fire- Warden-50) and Spartan (NSF-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emer- 4114411 gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local,visible sensor indication. Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A) in B210LP(A) Base DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability, especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often Addressing better than photoelectric detectors at sensing fast, flaming fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP 25,and 01 –50 with FireWarden 50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple base to simplify installation,service and maintenance. field cleaning. Mount base (all base types) on an electrical backbox which is Operation at least 1.5"(3.81 cm)deep. For a chart of compatible junction Withstands air velocities up to 4,000 feet-per-minute(20 m/ boxes,see DN 60054. • sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC • Factory preset at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring `T-taps" or branches are permitted for Style 4(Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED "blinks"when the unit is addressed (communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single gang box, 3.5" (8.89 cm) or 4.0" (10.16 cuit (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0"(10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient pro- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar cham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a Options more stable detector. • Remote LED output connection, PN RA100Z(A). DN-6995:C•12/07/2011—Page 1 of 2 Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use with a Each detector can have its sensitivity tested (required per DNRA duct detector housing; B210LPA base included. NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE:"A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15-32 VDC(peak). B210LPBP: Bulk pack of 6210LP;package contains 10. Standby current:300 pA 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA @ 24 VDC(latched"ON"). B501 BP: Bulk pack of B501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1"(5.33 cm)high; base determines diameter. Replaces B501 BH series bases in retrofit applications. -B210LP(A):6.1"(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1"(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 -B200SR(A):6.875"(17.46 cm)diameter. A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ -B224RB(A):6.2"(15.748 cm)diameter. 30 VDC inductive. Weight:3.6 oz.(102 g). B224B1(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F); for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B21OLP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature: 0°C-49°C(32°F-120°F). low-profile. Relative humidity: 10%-93%,non-condensing. F110BP:Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3-32 VDC. Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B21OLP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit tusng may be in process. Consult factory for latest listing sta M02-04-OO:Test magnet. • UL Listed:S1115. M02-09-00:Test magnet with telescoping handle. • ULC Listed:S911. XR2B: Detector removal tool. Allows installation and/or CSFM:7272-0028:0231. removal of detector heads from bases in high ceiling applica- • tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010: Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:`A"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B210LP base only;box of 10. included. NP-100A:Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International All Inc. ©2011. reserved. Unauthorized use of this document is strictly B210LP base included. prohib1 This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. C E R T F E We cannot cover all specific applications or anticipate all requirements. NY1INL3IN1&MINIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:C•12/07/2011 DN-6997:D•Al-320 NH-100(A) Seriesqt,) NOTIFIER® Intelligent Addressable Thermal Detectors for FireWarden Series by Honeywell Addressable General The NOTIFIER NH-100(A) Series thermal detectors are addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response.These sensors provide open- area protection and are intended for use with FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25)addressable Fire Alarm Control Panels(FACPs). The NH-100(A) and NH-100R(A) sensors provide fixed tem- perature alarm detection at 135°F (57°C). The NH-100R(A) sensor also responds to rate-of-rise conditions of greater than 15°F(8.3°C)per minute.The NH-100H(A)is a fixed high-tem perature detector that activates at 190°F (88°C). These ther- mal detectors provide addressable property protection in a variety of applications. NH-100(A) in B210LP(A) Base Two LEDs on each sensor light to provide a local,visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory,the RA100Z. • Low standby current. • 94-5V plastic flammability rating. Features Options: SLC loop: • Remote LED output connection to optional RA100Z remote • Two-wire SLC loop connection. LED annunciator. • Unit uses base for wiring. • Flanged surface mounting kit. Addressing: Installation • Addressable by device. Rotary, decimal addressing: 01 —99 with FireWarden-100- - NH 100(A) Series plug-in intelligent thermal detectors use a • 2, NSP-25,01 —50 with FireWarden-50. detachable base to simplify installation, service and mainte- nance. Installation instructions are shipped with each detector. Architecture: Mount base (all base types)on an electrical backbox which is • Sleek, low-profile,stylish design. at least 1.5"(3.81 cm)deep. For a chart of compatible junction • State-of-the-art thermistor technology for fast response. boxes,see DN-60054. • Integral communications and built-in device-type identifica- NOTE:Because of the inherent supervision provided by the SLC tion. loop, end-of-line resistors are not required. Wiring `T-taps" or • Built-in tamper resistant feature. branches are permitted for Style 4(Class"B")wiring only. • Built-in functional test switch activated by external magnet. Applications Operation: • Factory preset at 135°F(57°C)for the NH-100(A) and NH- Use thermal detectors for protection of property. 100R(A); 190°F(88°C)for the NH-100H(A). • Rate-of-rise triggers at 15°F(8.3°C) per minute for the NH- Construction100R(A). These detectors are constructed of off-white fire-resistant • 360°-field viewing angle of the visual alarm indicators (two plastic. The NH-100(A) Series plug-in intelligent thermal bicolor LEDs). LEDs blink red in Normal condition and turn detectors are designed to commercial standards and offer an on steady red in Alarm. attractive appearance. • Visible LEDs"blink"every time the unit is addressed. Mechanicals: Operation • Sealed against back pressure. Each NH-100(A)Series detector uses one of 99(FireWarden- 100-2, NSP-25)or 50(FireWarden-50) possible addresses on • SEMS screws for wiring of the separate base. a control panel SLC loop. It responds to regular polls from the • Designed for direct-surface or electrical-box mounting. control panel and reports its type and the status.If it receives a • Plugs into separate base for ease of installation and main- test command from the panel(or a local magnet test), it stimu- tenance. later its electronics and reports an alarm. It blinks its LEDs • Separate base allows interchange of photoelectric, ioniza when polled and turns the LEDs on when commanded by the tion and thermal sensors. panel.The NH-100(A)Series offers features and performance that represent the latest in thermal detector technology. Other system features: • Remote test feature from the panel. • Walk test with address display. DN-6997:D.5/17/13—Page 1 of 2 Spefications INTELLIGENT BASES Size:2.1"(5.3 cm)high; base determines diameter. NOTE:'A"suffix indicates ULC Listed model. —B210LP(A):6.1"(15.5 cm)diameter. NOTE:For details about intelligent bases and their mounting,see —B501(A):4.1"(10.4 cm)diameter. DN-60054. —B200SR(A):6.875"(17.46 cm)diameter. B210LP(A): Plug-in detector base (included); standard U.S. flanged low-profile mounting base. —B224RB(A):62'(15.748 cm)diameter. B210LPBP: Bulk pack of B210LP;package contains 10. Shipping weight:4.8 oz. (137 g). B501(A):Standard European flangeless mounting base. Installation temperature: —NH-100(A), NH-100R(A):—4°F to 100°F(-20°C to 38°C). 8501 BP: Bulk pack of B501;package contains 10. —NH-100H(A):—4°F to 150°F(-20°C to 66°C). B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Humidity range: 10% to 93% relative humidity (noncon- Replaces B501 BH series bases in retrofit applications. densing). B224RB(A): Plug-in System Sensor relay base. Screw termi- Voltage range: 15 to 32 VDC peak. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 Standby current: 300 pA @ 24 VDC (one communication A EP 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A every five seconds with LED blink enabled). 30 VDC inductive. LED current:6.5 mA @ 24 VDC. B224BI(A): Plug-in System Sensor isolator detector base. Mounting: B210LP(A) flanged base, included. See "Product Maximum 25 devices between isolator bases(see DN-6994). Line Information: Intelligent Bases"if using a different base. ACCESSORIES Fixed-temperature setpoint: 135°F (57°C) for the NH-100 F110: Retrofit flange to convert B210LP(A) to match the and NH-100R(A)(A); 190°F(88°C)for the NH-100H(A). B710LP(A) profile, or to convert older high-profile bases to Rate-of-rise detection:responds to greater than 15°F(8.3°C) low profile. per minute. F110BP:Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings and Approvals RA100Z(A): Remote LED annunciator.3—32 VDC. Mounts to Listings and approvals below apply to the NH-100(A) Series a U.S. single-gang electrical box. For use with B501(A) and detectors. In some cases, certain modules may not be listed B210LP(A)bases only. by certain approval agencies, or listing may be in process. SMB600:Surface mounting kit Consult factory for latest listing status. • UL Listed:S747. M02-04-00:Test magnet. • ULC Listed:S747. M02-09-00:Test magnet with telescoping handle. • CSFM:7270-0028:0234. XR2B: Detector removal tool. Allows installation and/or • MEA:387-02-E Vol. II. removal of detector heads from bases in high ceiling applica- tions. • FM approved. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 Product Line Information m)sections. T55-127-010: Detector removal tool without pole. NOTE:'A"suffix indicates ULC Listed model. NH-100: Intelligent thermal sensor; 135° F (57° C); B210LP base included. NH-100A: Same as NH-100 but with ULC Listing; B210LPA base included. NH-100R: Same as NH-100 with rate-of-rise feature; B210LP base included. NH-100RA:Same as NH-100R but with ULC Listing;B210LPA base included. NH-100H: Intelligent fixed high-temperature thermal detector; 190°F(88°C); B210LP base included. NH-100HA:Same as NH-100H but with ULC Listing;B210LPA base included. NOTIFIER® and FireWarden® are registered trademarks of Honeywell International Inc. ©2013. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. _. We try to keep our product information up-to-date and accurate. G E RT F E We cannot cover all specific applications or anticipate all requirements. ENRINEERINE 8 MANIEAENRINR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6997:D•5/17/13 DN-60054:F•H-320 Intelligent Bases NTI Fl R® B501(A), B200S(A), B200SR(A), B210LP(A), B2241B1(A), B224RB(A), by Honeywell Mounting Kits, and Accessories Intelligent/Addressable Devices General Intelligent FlashScan®and CLIP mounting bases and kits pro- �u r vide a variety of ways to install NOTIFIER detectors in any application. Intelligent detectors can be mounted in either a flanged or flangeless bases depending on junction box selec- z /04 tion (see Junction Box Selection Guide). Across this product line, detectors plug in easily to the base with SEMS screws; Flangeless Mounting Base Flanged Mounting Base and models employ various 12 to 24 AWG wire ranges. B501(A) B210LP(A) Relay, isolator, and sounder bases can be used to meet local code requirements. Relay bases provide one Form-C contact relay for control of auxiliary functions such as door do- sure lo sure and elevator recall. Isolator bases allow loops to continue • to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-temporal pattern versions depending on X whether the signal is to be used for evacuation purposes. Specifications Sounder Base Relay Base B200S(A),B200SR(A), B224RB(A) Diameter: B200SCOA —B501:4.1"(104 mm). —B200S,high-volume*:Greater than 85 dBA minimum. —B224B1, B224RB,B210LP:6.1" (155 mm). —B200S,low-volume`:Greater than 75 dBA minimum. —B200S/SR/SCOA:6.875"(17.46 cm). —B200SR*:Greater than 85 dBA minimum. Wire gauge: —B200SCOA, high-volume": Greater than 87 dBA mini- -B224BI, B224RB: 14 to 24 AWG. mum. —B210LP,B501,B200S/SR/SCOA: 12 to 24 AWG. —B200SCOA,low-volume":Greater than 85 dBA minimum Temperature range: *Measured in a UL reverberant room at 10 feet,24 Volts(continuous tone) `"Measured in a ULC anechoic room at 10 feet,24 Volts continuous tone) —B224B1, B224RB, B200S/SR/SCOA: 32°F to 120°F (0°C to 49°C). FOR B224RB,B224B1: —B210LP, B501:-4°F to 150°F(-20°C to 66°C). Operating voltage: 15 to 32 VDC(powered by SLC). Humidity range: 10%to 93%RH,non-condensing. Standby ratings:<500 pA maximum @ 24 VDC. System temperature and humidity ranges: This system Set time (B224RB only): short delay 55 to 90 msec; long meets NFPA requirements for operation at 0°C to 49°C (32°F delay 6 to 9 seconds. to 120°F); and ata relative humidity (noncondensing) of 85% Reset time(B224RB only):20 msec maximum. at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F± 1.1°F) per ULC. However, the useful life of the sys- Relay characteristics(B224RB only):two-coil latching relay; tern's standby batteries and the electronic components may be one Form-C contact; ratings(UUCSA): 0.9 A @ 125 VAC,0.9 adversely affected by extreme temperature ranges and humid- A @ 110 VDC,and 3.0 A @ 30 VDC. ity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room Product Line Information temperature of 15°C to 27°C(60°F to 80°F). INTELLIGENT BASES Electrical Ratings B501: Flangeless mounting base. FOR B200S/SR/SCOA: B501A: Flangeless mounting base,ULC Listed. External supply voltage: 16 to 33 VDC(VFWR) B501 BP: Bulk pack of B501 (10). Standby current:500 pA maximum. B210LP: Flanged mounting base. Alarm current: B210LPA: Flanged mounting base, ULC listed —B200S:35 mA maximum at high-volume setting; B210LPBP: Bulk pack of B210LP(10). 15 mA maximum at low-volume setting. B200S: Intelligent addressable sounder base capable of pro- -B200SR:35 mA maximum. ducing sound output in high or low volume with ANSI Temporal —B200SCOA:40mA Max. (DC),70mA Max. (FWR) 3,ANSI Temporal 4,continuous tone,marching tone,and cus- tom tone. Uses FlashScan protocol. Only compatible with the SLC operating voltage: 15 to 32 VDC. NFS-320, NFS2-640 and NFS2-3030 operating version with SLC standby current:300 pA. version 15.0 or higher panel firmware. Sound output: B200SA: Same as B200S with ULC-listing. DN-60054:F•09/03/2013—Page 1 of 2 B200SCOA: Same as B200S with ULC-listing and CO detec- M02-09-00:Test magnet with telescoping handle. tor markings in English/French (required in Canada for ULC XR2B: Detector removal tool for current heads (T55-127-010 applications with FCO-851A). included). B200SR: Intelligent sounder base capable of producing sound XR2: Detector Remove Tool for use with low profile detector output with ANSI Temporal 3 or continuous tone. heads,and FSL-751. B200SRA:Same as B200SR with ULC listing. XP-4: Extension pole for XR2/B(5 to 15 ft/1.524 to 4.572 m). B224RB: Relay base. T55-127-010:Detector removal head. B224RBA: Relay base,ULC Listed. BCK-200B: Black detector kit, package of 10 (for use with B224BI: Isolator base. photo and ion detectors). B224BIA: Isolator base,ULC Listed. WCK-200B: White detector kit, package of 10 (for use with MOUNTING KITS AND ACCESSORIES photo and ion detectors). SMB600:Surface mounting kit,flanged. Agency Listings and Approvals F110: Retrofit flange for converting high-profile bases to low- The listings and approvals below apply to intelligent bases as profile. noted. In some cases,certain modules or applications may not F110BP: Bulk pack of F110(10). be listed by certain approval agencies,or listing may be in pro- F210: Accessory flange ring for B210LP(A) base (new cess.Consult factory for latest listing status. design).6-inch diameter. • UL Listed:S911 F210BP:Bulk pack of F210(10). • ULC Listed:S911 RA100Z: Remote LED annunciator. FM Approved • RA100ZA: Remote LED annunciator, ULC Listed. MEA:22-95-E,205-94-E Vol.2;257-06-E M02-04-00: Detector test magnet. • CSFM: 7300-1653:0126, 7135-1653:0213, 7300- 1653:0109 Junction Box Selection Guide Snge 4.0"Sq. il Base Models ng3.5"Oct. 4.0"Oct. 4.0"Sq. with 3.0" 50 mm 60 mm 70 mm 75 mm mud ring 6200S,B200SR, Yes Yes Yes Yes Yes No No No No B200SCOA B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224B1 No Yes Yes Yes No No No Yes Yes NOTE:Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. FlashScan®,NOTIFIER®and System Sensor®are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. '�0 9001 This document is not intended to be used for installation purposes. *•.*** We try to keep our product information up-to-date and accurate. «**.** CERTIFIED We cannot cover all specific applications or anticipate all requirements. 9Y61NEMIN6 SMMAHICTYRIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60054:F•09/03/2013 dn-60383:A2 NC-100R(A) NOTIFIER® Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices,such as fans,dampers, door hold ers, control equipment, etc.Addressability allows the dry con- tact to be activated, either manually or through panel programming,on a select basis. Features • Built-in type identification automatically identifies these • " • w• " devices to the control panel. ^ • Internal circuitry and relay powered directly by two-wire = *.ax; SLC loop. ab •¢ • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • activated. flik o • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset four-wire smoke detector power. Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll(CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command, it activates its internal relay. Maximum Current Rotary switches set a unique address for each module. The Load Description Application Voltage Rating address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(L/R=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. G E R T F E O We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANIFACIURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383.A2•06/17/10 dn-7000:a2•Al-360 NC-100(A) ® NOTIFIER® Control Module for FireWarden Series Panels by Honeywell Addressable General The NC-100(A) Addressable Control Module provides NOTI- FIER's FireWarden Series intelligent control panels a super- vised Class B (Style Y) of Class A (Style Z) circuit for e . Notification Appliances (horns, strobes, etc.). Addressability allows the NC-100(A) to be activated, either manuallyor through panel programming,on a select(zone or area of coy- erage)basis. '.• rt •1en �in Features ,,,: ": • • Built-in type identification automatically identifies these devices to the control panel. �� n • Internal circuitry powered directly by two-wire SLC loop. , The NC-100(A) module requires power(for horns, strobes, .x etc.). • Integral LED "blinks" when communicating, and turns on steady when activated. • High noise immunity(EMF/RFI). • The NC-100(A) may be used to switch 24-volt NAC power. • Wide viewing angle of LED. NC-100(A) • SEMS screws with clamping plates for wiring ease. • Direct Decade entry of address: 01 —99 with FireWarden- 100-2(C),or 01-50 with the FireWarden-50(C). Specifications Applications Normal operating voltage: 15 to 32 VDC. The NC-100(A)is used to switch 24 VDC audible/visual power. Maximum SLC current draw:6.5 mA(LED on). Average operating current:350 pA(LED flashing). Construction External supply voltage:maximum 80 volts(RMS or DC). • The face plate is made of off-white heat-resistant plastic. Drain on external supply: 2 mA maximum (using internal • Controls include two rotary switches for direct-dial entry of EOL relay). address setting. EOL resistance:47K ohms. • The NC-100(A) is configured for a single Class B(Style Y) Temperature range:32°F to 120°F(0°C to 49°C). or Class A(Style Z)Notification Appliance Circuit. Humidity range: 10%to 93%non-condensing. OperationDimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Each NC-100(A) uses one of the module addresses on a SLC 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x loop. It responds to regular polls from the control panel and 2.125"(5.398 cm)deep box. reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED Agency Listings and Approvals blinks with each poll received. On command, it activates its In some cases, certain modules may not be listed by certain internal relay.The NC-100(A) supervises Class B(Style Y)or approval agencies, or listing may be in process. Consult fac- Class A(Style Z)notification or control circuits. tory for latest listing status. Upon code command from the panel, the NC-100(A) will dis- • FM approved connect the supervision and connect the external power sup- ve ply in the proper polarity across the load device. The • UL/ULC Listed:file S635. disconnection of the supervision provides a positive indication • CSFM approved:file 7300-0028:230. to the panel that the control relay actually turned ON. The • MEA approved:file 72-01-E Vol.2. external power supply is always relay-isolated from the com- munication loop so that a trouble condition on the external power supply will never interfere with the rest of the system. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE(not settable)will identify the module to the con- trol panel. dn-7000:a2.06/17/10—Page 1 of 2 Contact Ratings Current Maximum Load Application Rating Voltage Description pp 3 A 30 VDC Resistive Non-Coded 2 A 30 VDC Resistive Coded .9 A 110 VDC Resistive Non-Coded .9 A 125 VDC Resistive Non-Coded .5 A 30 VDC Inductive Coded (L/R=Sms) 1 A 30 VDC Inductive Coded (L/R=2ms) .3 A 125 VAC Inductive Non-Coded (PF=0.35) Inductive 1.5 A 25 VAC (PF=0.35) Non-Coded Inductive .7 A 70.7 VAC (PF=0.35) Non-Coded Inductive 2 A 25 VAC (PF=0.35) Non-Coded Product Line Information NC-100: Intelligent addressable control module. NC-100(A): Intelligent addressable control module, ULC listed version. SMB500:Optional surface-mount backbox. CB500: Optional control module barrier, required by UL for separating power-limited and non-power-limited wiring in the same junction box as NC-100(A). NOTE: For installation instructions, see document 156-2592-001 and refer to the SLC Wiring Manual, document 52304. The NC- 100R(A) relay module, previously on this data sheet, is now on DN-60383. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Iso oo 1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. CERT F E O We cannot cover all specific applications or anticipate all requirements. ENGINEERING 8 MANIFACTININS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-7000:a2•06/17/10 Monitor Modules DN-6999:C NMM-100(A), NMM-100P(A), N OT I F I E R° NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull ry � stations, or monitor and power a circuit of two-wire smoke t .• detectors(NZM-100(A)). CENLR 9" NMM-100(A)is a standard-sized module(typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (, (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that .` n supervises a Style B (Class B) circuit of dry-contact input : 5 devices. Its compact design allows the NMM-100P(A) to be 4146 406 * pi mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the control panel. mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop.No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 —99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 —50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 corn- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit (IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 NMM-100P(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. • as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop. No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. J 3 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 —99 on FireWarden- s' 13 , 2 2 100-2,01 —50 on FireWarden-50. 3 �� 4 LOOP� � 4 • LED flashes during normal operation. • LED latches steady to indicate alarm on command from 10 9 $ 7 6 5 9 8 7 6 5 control panel. TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- - n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This a module allows intelligent panels to interface and monitor two- k 1_ wire conventional smoke detectors. It transmits the status(nor- O W p u mal,open,or alarm)of one full zone of conventional detectors JO W V back to the control panel. All two-wire detectors being moni- j m tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NMM-100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B) Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range: 10%to 93%noncondensing. Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); The NDM-100(A) Dual Monitor Module is intended for use in 227-03-E Vol,3(NDM-100) intelligent, two-wire systems. It provides two independent two- wire initiating device circuits(IDCs)at two separate,consecutive Product Line Information addresses. It is capable of monitoring normally open contact fire NOTE:"A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel NMM-100 A : Monitor module. controlled LED. ( ) NOTE: The NDM-100(A)provides two Style B(Class B)IDC cir- NMM-100P(A):Monitor module, miniature. cuits ONLY. Style D(Class A)IDC circuits are NOT supported in NZM-100(A): Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual, two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0,2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4"(10.16 cm)square,2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and FireWatch,"is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E RT F 1 E We cannot cover all specific applications or anticipate all requirements. ENSINEEIINC&NIINIE IUM& All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 SYSTEM �...� SENSOR® LM Indoor Selectable- . Output Horns, Strobes, and Horn Strobes for r �� ., r Wall Applications SpectrAlerp Advance audible visible notification products SPECT Wert are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile and • Plug-in design with minimal intrusion into the back box easy-to-use line of horns,strobes,and horn strobes in the industry. With white and red plastic housings,wall and ceiling mounting • Tamper-resistant construction options,and plain and FIRE-printed devices,SpectrAlert Advance • Automatic selection of 12-or 24-volt operation at can meet virtually any application requirement. 15 and 15/75 candela Field selectable candela settings on wall units: 15, 15/75, Like the entire SpectrAlert Advance product line,wall-mount horns, • 30,75,95, 110, 115, 135, 150, 177,and 185 strobes,and horn strobes include a variety of features that increase their application versatility while simplifying installation.All devices • Horn rated at 88+dBA at 16 volts feature plug-in designs with minimal intrusion into the back box, • Rotary switch for horn tone and three volume selections making installations fast and foolproof while virtually eliminating • Universal mounting plate for wall units costly and time-consuming ground faults. • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,SpectrAlert Advance utilizes a universal mounting plate • Electrically Compatible with legacy SpectrAlert devices with an onboard shorting spring,so installers can test wiring • Compatible with MDL3 sync module continuity before the device is installed. • Listed for ceiling or wall mounting Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING MEA LISTED APPROVED approved 7125-1653:166(indoor strobes) 7125-1653:188(horn strobes, 54011(chimes,hors strobes,horns) 3023572 MEA452-05-E chime strobes) 95512(strobes) 7135-1653:189(horns,chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns,strobes,and horn strobes shall mount to a standard 4 x 4 x 11/cinch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuii°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, 110, 115,135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.On four-wire products,the strobe shall be powered independently of the sounder.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Rangel 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Trim Ring Dimensions(sold as a 5 pack)(TR-HS) 5.7"L x 4.8"W x 0.35"D(145 mm L x 122 mm W x 9 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.#iom Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 - UL Max.Current Draw(mA RMS),2-Win:Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 81- Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobes. SpectrAlert Advance Dimensions 4.7" 2.5''—. r IN Pair I I 11111 ®ZZI '. 111 5.6" 1111) • IIII Wall-mount horn strobes . SpectrAlert Advance Ordering Information Model Description Model Description Wall Horn Strobes Wall Strobes(cont.) P2R 2-Wire Horn Strobe,Standard cd,Red SRH Strobe,High cd,Red P2R-P 2-Wire Horn Strobe,Standard cd,Red,Plain SRH-P Strobe,High cd,Red,Plain P2R-SP 2-Wire Horn Strobe,Standard cd,Red, "FUEGO" SRH-SP Strobe,High cd,Red,"FUEGO" P2RH 2-Wire Horn Strobe,High cd,Red SW Strobe,Standard cd,White P2RH-P 2-Wire Horn Strobe,High cd,Red,Plain SW-P Strobe,Standard cd,White,Plain P2W 2-Wire Horn Strobe,Standard cd,White SWH Strobe,High cd,White P2W-P 2-Wire Horn Strobe,Standard cd,White,Plain SWH-P Strobe,High cd,White,Plain P2WH 2-Wire Horn Strobe,High cd,White Horns P2WH-P 2-Wire Horn Strobe,High cd,White,Plain HR Horn,Red P4R 4-Wire Horn Strobe,Standard cd,Red HW Horn,White P4R-P 4-Wire Horn Strobe,Standard cd,Red,Plain Accessories P4RH 4-Wire Horn Strobe,High cd,Red TR-HS Trim Ring,Wall,Red P4W 4-Wire Horn Strobe,Standard cd,White SBBR Indoor Surface Mount Back Box,Red Wall Strobes SBBW Indoor Surface Mount Back Box,White SR Strobe,Standard cd,Red SR-P Strobe,Standard cd,Red,Plain SR-SP Strobe,Standard cd,Red,"FUEGO" Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-SP models have"FUEGO"marking on cover "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings. "High cd"refers to strobes that include 135,150,177,and 185 candela settings. ``� SYSTEM 3825 Ohio Avenue•St.Charles, IL 60174 ©zo,asystemsensor. 1�, SE/i/SO►R� Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change wiihoutnotice.Visit systemsensor.com for current product information,including the latest version of this data sheet. www.systemsensor.com Avos10201•1/14 • SYSTEM SENSOR° r Selectable-Output Low Frequency t# Sounder and Low F " ' . F Frequency Sounder 4g ; ) t R Strobes for WallE _ t Applications SpectrAlert°Advance audible visible notification products SPECTI ert A N G are rich with features guaranteed to cut installation times and maximize profits. Features The SpectrAlert Advance series offers the most versatile • 520 Hz± 10%square wave tone and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry.With white and red plastic housings, • Plug-in design with minimal intrusion into the back box dual listed for wall and ceiling mounting,SpectrAlert Advance can • Tamper-resistant construction meet virtually any application requirement. • Field-selectable candela settings on wall units: 135, 150, 177,and 185 The wall-mount low frequency sounder,and low frequency sounder strobes were designed to address the NFPA 72 sleeping space • Rotary switch for low frequency sounder tone requirements that require a low frequency notification appliance that • Universal mounting plate for wall units operates within frequency range of 520 Hz± 10%and is of a square • Mounting plate shorting spring checks wiring continuity before wave tone.Like the entire SpectrAlert Advance product line they device installation include a variety of features that increase their application versatility while simplifying installation.All devices feature plug-in designs • Electrically compatible with legacy SpectrAlert devices with minimal intrusion into the back box,making installations fast • Compatible with MDL3 sync module and foolproof while virtually eliminating costly and time-consuming • Listed for ceiling or wall mounting ground faults. To further simplify installation and protect devices from construction damage,SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring,so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, Agency Listings automatic selection of 12-or 24-volt operation,and a rotary switch for 520 Hz low frequency sounder tones, SIGNALING 420 ® MEA LISTED APPROVED approved f' 1 54011(sounder) 3047563 MEA452-05-E 7135-1653:0223 S5512(strobes) 7125-1653:0224 SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box,4-inch octagon back box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•CircuitrM Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings including 135,150, 177, and 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone and have a permanent marking on the housing that reads"low frequency sounder". Low Frequency Sounder The low frequency sounder shall be a System Sensor SpectrAlert Advance Model listed to UL 464 and shall be approved for fire protective service.The low frequency sounder and the Sync•CircuitTM MDL3 Module accessory,if used,shall be powered from a notification appliance circuit output and shall operate on a nominal 12 or 24 volts(includes fire alarm panels with built in sync).When used with the Sync•Circuit Module MDL3, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three pattern,non-temporal(continuous)pattern and coded supply within the frequency range of 520Hz±10%square wave tone.The low frequency sounder shall operate on a coded or non-coded power supply. Low Frequency Sounder Strobe Combination The low frequency sounder strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/16 x 411/16 x 21/2-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Frequency Range 520 Hz±10% Strobe Flash Rate 1 flash per second Nominal Voltage Low Frequency Sounder Regulated 12 DC/FWR or regulated 24 DC/FWR1 Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 6.4 inches L x 4.7 inches W x 2.5 inches D (162 mm L x 119 mm W x 64 mm D) Sounder Dimensions 5.6 inches L x 4.7 inches W x 1.3 inches D (142mmLx 119 mm W x 33 mm D) Low Frequency Sounder/Strobe with Surface Mount Back Box 6.4 inches L x 4.7 inches W x 4.3 inches D Dimensions(SBBR,SBBW) (162 mm L x 120 mm W x 108 mm D) Low Frequency Sounder with Surface Mount Back Box Dimensions 5.7 inches L x 4.8 inches W x 3 inches D (SBBR,SBBW) (145 mm L x 120 mm W x 76 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 UL Max.Low Frequency Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal3 High 191 262 138 166 Continuous High 292 384 138 208 Coded High 292 388 153 205 UL Max.Current Draw(mA RMS),2-Wire Low Frequency Sounder Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal 3 277 292 325 344 Temporal 3 296 309 343 351 Continuous 337 362 387 417 Continuous 393 395 432 433 Low Frequency Sounder Tones and Sound Output Data Low Frequency Sounder and Low Frequency Sounder Strobe Output(dBA) 8-17.5 16-33 24-Volt Nominal Volts Volts Reverberant Anechoic Switch Position Sound Pattern DC FWR DC FWR DC FWR DC FWR 1 Temporal 3 76 76 76 76 76 76 86 86 2 Continuous 80 80 80 80 80 80 90 90 • 3t Coded 80 80 80 80 80 80 90 90 t Sounder ratings provided are for continuous voltage as provided by the NAC SpectrAlert Advance Dimensions 4.7 in. ► 2.5 in, P 4.7 in. 0-1.3 in.-0- 11 'lIi lin 1 -' Iry 11 _ • ------- oIl In ®1I I) j6.4 In. JJ56In. ) El I , °( ( I■■II111 I n �a- Wall-mount low frequency sounder strobes Wall-mount low frequency sounder SpectrAlert Advance Ordering Information Model Description Wall Low Frequency Sounder Strobes P2RH-LF 2-Wire Low Frequency Sounder Strobe,High cd,Red P2WH-LF 2-Wire Low Frequency Sounder Strobe,High cd,White Low Frequency Sounders HR-LF Low Frequency Sounder,Red HW-LF Low Frequency Sounder,White Accessories SBBR Surface Mount Back Box,Wall,Red SBBW Surface Mount Back Box,Wall,White TR-HS Trim Ring,Wall,Red Notes: "High cd"refers to strobes thatinclude135,150,177,and 185 candela settings. SYS3825 Ohio Avenue•St.Charles, IL 60174 ©2014 System Sensor. �� SENSOR'``TEIY!���� Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to change without notice.Visit systemsensor.com for current product information,including the latest version of this data sheet. www.systemsensor.com AVDS16403.5/14 .SYSTEM �$ SENSOR® Outdoor Selectable- Output Horns, AP Strobes, and Horn Strobes for Wall Applications SPECTFIert SpectrAlert®Advance outdoor audible visible products are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from—40°F to 151°F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices. Plastic back boxes feature removable side flanges and improved resistance to saltwater 0 SIGNAUNG corrosion.Knock-outs located on the back eliminate the need to drill '° holes for screw-in mounting. Plastic and metal weatherproof back ylEA boxes come with 3A-inch top and bottom conduit entries and 3A-inch LISTED 7300-,555:,58(outdoorstrobes) 7125,s53,aahorsstrobes, knock-outs at the back.A screw-in NPT lu with an asket Soo„(chimes,horn strobes,horns) APPROVED proved chime strobes) plug 0-ring g S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn, Strobe,and Horn Strobe Specifications Architect/Engineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync•Circuif°Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts,Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110, 115, 135, 150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. Physical/Electrical Specifications Operating Temperature -40°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6"L x 4.7"W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7"L x 5.1"W x 2.0"D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,Standard Candela Range(15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 ed) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output(dBA) candela ratings must be reduced in accordance with 8-17.5 16-33 24-Volt Nominal this table. Strobe Output(cd) Switch Sound Volts Volts Reverberant Anechoic Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at—40°F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 Non- 75 44 4 TemporalHigh 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 110 110 Temporal 78 78 85 85 90 90 98 98 115 115 6 Non- Low 75 75 81 81 88 84 96 92 135 135 Temporal 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 177 81' Coded Medium 78 78 85 85 90 90 97 98 185 185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS012OI SpectrAlert Advance Diagrams r____4.7" .I 2.5'� _ : Do ner:ir ,. I I_ ® I.L _. /.., /.. 5.6" �._ ,I, .F..==., ..=,=. O ,� I. Wall-Mount Horn Strobes `iL�� Wall Plastic Weatherproof Back Box �,,— alt _ II T1s Ni Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Wall Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK`t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RK1- 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK"t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK`t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add"-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75,30,75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 02012 System Sensor. > SENSOR' 3825 Ohio Avenue•St.Charles, IL 60174 Pror ecifications subject to change without notice.Visitf thisdsensoncom Phone:800-SENSOR2•Fax:630-377-6495 for current product information,including the latest version of data sheet. AVDS01201•3/12