Plans (32) ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. THIS SYSTEM IS GRID—INTERTIED VIA A AC ALTERNATING CURRENT UL—LISTED POWER—CONDITIONING INVERTER. - BLDG BUILDING 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. RECEilii2:1 ) CONC CONCRETE 3. A NATIONALLY—RECOGNIZED TESTING DC DIRECT CURRENT LABORATORY SHALL LIST ALL EQUIPMENT IN EGC EQUIPMENT GROUNDING CONDUCTOR COMPLIANCE WITH ART. 110.3. OCT 20 - (E) EXISTING 4. WHERE ALL TERMINALS OF THE DISCONNECTING EMT ELECTRICAL METALLIC TUBING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, COY OF 7'j��gD � (�} FSB FIRE SET-BACK A SIGN WILL BE PROVIDED WARNING OF THE D FOR CODE COMPLIANCE �fl!ilt�'l z. GALV GALVANIZED HAZARDS PER ART. 690.17. Approved: GEC GROUNDING ELECTRODE CONDUCTOR 5. EACH UNGROUNDED CONDUCTOR OF THE PP [ GND GROUND MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY OTC: [ I HDG HOT DIPPED GALVANIZED PHASE AND SYSTEM PER ART. 210.5. Permit#�: 0 IA—CO ( I CURRENT 6. CIRCUITS OVER 250V TO GROUND SHALL Imp CURRENT AT MAX POWER COMPLY WITH ART. 250.97, 250.92(B). Address: (2R � C cl0 Isc SHORT CIRCUIT CURRENT 7. DC CONDUCTORS EITHER DO NOT ENTER Suite#: kVA KILOVOLT AMPERE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR (064K:— LBW kW KILOWATT ENCLOSURES TO THE FIRST ACCESSIBLE DC By: C Date: l LBW LOAD BEARING WALL DISCONNECTING MEANS PER ART. 690.31(E). MIN MINIMUM 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN , (N) NEW RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY /� NEUT NEUTRAL UL LISTING. OFFICE COPY NTS NOT TO SCALE 9. MODULE FRAMES SHALL BE GROUNDED AT THE OC ON CENTER UL-LISTED LOCATION PROVIDED BY THEo PL PROPERTY LINE MANUFACTURER USING UL LISTED GROUNDING P01 POINT OF INTERCONNECTION HARDWARE. PV PHOTOVOLTAIC 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE SCH SCHEDULE BONDED WITH EQUIPMENT GROUND CONDUCTORS. S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT VmpocVOLTAGE AT MAX POWER IRCU INDEX Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP W WATT 3R NEMA 3R, RAINTIGHT PV1 COVER SHEET 'g , PV2 SITE PLAN ' + ' e •' `= ` '. ' PV3 STRUCTURAL VIEWS PV4 UPLIFT "`�`"" ` '"" " .- • ` PV5 THREE LINEDIAGRAMLICENSE GENERAL NOTES 'el ' ' y_ , ,. . ri - Cutsheets Attached OR j'[1 180498 1. ALL WORK TO BE DONE TO THE 2010 OBC k" a II . f a.... BASED ON THE 2009 IBC. ' ; ` r 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRIC CODE AS .; " ' k AMENDED BY THE OREGON ELECTRICAL SPECIALTYlo . °" `s! ,� ' — CODE. +` MODULE GROUNDING METHOD: ZEP SOLAR .• '" ' AHJ: Tigard - t , ;'. REV BY DATE COMMENTS ,�. :01:4::,,..:A. REVIEWE.,\, r ' , • �,d "`, .it_ REV A NAME DATE COMMENTS. ' _ '''k is �,'< . . . UTILITY: Portland General Electric : . _ . `' _ e to '4-. es a — r and �regor�, *Stet U.S. eo cadJ -. .p CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J.3-9722198 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THEMA, YILAM MA RESIDENCE Dave Williamson Vic_,!.• • BENEFIT OF ANYONE EXCEPT IN WHOLE INC., MOUNTING SYSTEM; 12959 SW GALLIN CT ,-Solaf City NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Cam Mount Type C �•.,� 'g PART TO OTHERS OUTSIDE THE RECIPIENTS p 3.8 2 5 K W P V ARRAY �;� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97223 .- THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-255PA05.18 3055 Clear-view Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET. REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. (971) 998-2589 COVER SHEET PV 1 10/2/2014 T:(650)638-1028 F:(650)638-1029 ABB# PVI-3.0-OUTD-S-US-Z-A (888)—SOL—CITY(765-2489)www.solarcity.com PITCH: 32 ARRAY PITCH:32 MP1 AZIMUTH:270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 2 Stories r HBO O LEGEND O (E) UTILITY METER & WARNING LABEL `° INVERTER W/ INTEGRATED DC DISCO I 1 I ' ® & WARNING LABELS • NH DC DISCONNECT & WARNING LABELS AC -.� AC DISCONNECT & WARNING LABELS 0 DC JUNCTION/COMBINER BOX & LABELS — 1 • 1 0 DISTRIBUTION PANEL & LABELS NN, Lc LOAD CENTER & WARNING LABELS ODEDICATED PV SYSTEM METER I O STANDOFF LOCATIONS (E)DRIVEWAY CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR 12959 sw Gallin ct GATE/FENCE O HEAT PRODUCING VENTS ARE RED r,--..-1 I‘ ;" INTERIOR EQUIPMENT IS DASHED L-21 SITE PLAN N TOTAL ARRAY AREA (SF): 270 Scale:1/16" = 1' �, TOTAL ROOF AREA (SF): 3249w INFE TOTAL ARRAY AREA IS a 8.3 01' 16' 32' PERCENT OF TOTAL ROOF AREA mlle61m. s CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722198 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MA, YILAM MA RESIDENCE Dave Williamson �e.,. ORBENEFIT L ANYONE CEXCEPTOSED IN SOLARCITYLEINC., MOUNTING SYSTEM: .,,SOlarClty. NOR SHALL IT BE DISCLOSED IN WHOLE OR., CompMount Type C 12959 SW GALLIN CT 3.825 KW PV ARRAY PART TI , OUTSIDE THE RECIPIENTS TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-255PA05.18 3055 Mateo, A Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET REV: DATE: San CA 94402 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0-OUTD-S-US-Z-A (971) 998-2589 SITE PLAN PV 2 10/2/2014 T:(650)638-1028 F:(650)638-1029 (BBB)—SOL—qTY(765-2489)www.solarcity.com (E) 2x4 PRE—MANUFACTURED TRUSS - CD STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS t OF THE OSISC SECTION 305.4 4"- -8 ,'1 4'-8" 5'-9„ il III (E) LBW ASIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 17" TOP CHORD 2x4 @ 24 OC ROOF AZI 270 PITCH 32 STORIES: 2 ARRAY AZI 270 PITCH 32 BOT CHORD 2x4 @24" OC Comp Shingle PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) - _ HOLE. (4) (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT C __ ZEP FLASHING C t�iTf� We M (3)) INSERT FLASHING. (E) COMP. SHINGLE i' a 1 (4) PLACE MOUNT. (E) ROOF ---___ AULM =II INSTALL S LL LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER 1 STANDOFF S+ Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722198 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT EE USED FOR THE MA, YILAM MA RESIDENCE Dave Williamson `,'SoIarCityBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 12959 SW GALLIN CTNOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount T e C �'I PART TO OTHERS OUTSIDE THE RECIPIENTS 3.825 KW PV ARRAY 1�� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97223 THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-255PA05.18 3055 earview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. (971) 998-2589 T:(650)638 1028 F:(650)638-1029 ABB# PVI-3.0-OUTD-S-US-Z-A STRUCTURAL VIEWS PV 3 10/2/2014 (888)-SOL-CITY(765-2489)www.solarcity.aom UPLIFT CALCULATIONS 10.02.2014 SolarCity SleekMountTM PV System Version#39.1 Structural Desian Software Project Information&Table Of Contents Risk Category: II PV System Type SolarCity SleekMount"" Comp Roof Comp Roof Layers of Comp Roofing 1 Roof Slope 32° Rafter Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 264 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf ASCE Table 7-1 Surrounding Roof Snow 100% 25.0 psf ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq: 7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C Section 6.5.6.3 Roof Style Gable/Hip Roof 'Fig.6-11B/CTD-14AJU Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6-11B/C'D-14,4;8 Ext.Pressure Coefficient(Down) GCp(Down) 0.88 Fig.6-1113/C/0-14A/a Design Wind Pressure p p= qh(GCp) Equation 6-22 Wind Pressure Up p(up) -17.7 psf Wind Pressure Down p(down) 16.3 psf Allowable Standoff Spacings X-Direction Y-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -315 lbs Uplift Capacity of Standoff T-allow 500 lbs • Standoff Demand/Capacity DCR 63.0% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 17" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -349 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCR 69.8% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722198 0 O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINEDEEFITSHALL NOT BE USED FOR THE MA, YILAM MA RESIDENCE Dave Williamson ` ,•SolarCityBENEFIT OF ANYONE EXCEPT SOLARCITY INC.. MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12959 SW GALLIN CT 3.825 KW PV ARRAY Pit PART TO OTHERS OUTSIDE THE RECIPIENTS TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-255PA05.18 3055 t e,CA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE: San Moteo,CA 94402 PERMISSION OF SOLARCITY INC. (971) 998-2589 UPLIFT CALCULATIONS PV 4 10/2/2014 T:(650)638-1028 F:(650)638-1029 ABB# PVI-3.0—OUTD—S—US—Z—A (888)—SOL—CITY(765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number: Square D Inv 1: DC Ungrounded INV 1 —(1)ABB# PVI-3.0—OUTD—S—US—Z—A LABEL: A ## 80498 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23 786 666 FCI Inverter; Zigbee 3000W, 240V, 96% —(15)TRINA M SOLAR 255WM232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled 18 ORGC,ICGC11 Underground Service Entrance INV 2 Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENI1FIER (E 200A MAIN SERVICE PANEL E) 200A/2P MAIN CIRCUIT BREAKER (E) WIRING Inverter 1 IND COOPER CUTLER—HAMMER 200A/2P Meter Socket Disconnect (3) ABB c) DC+ Vstart = DEFAULT 9 ' (E) LOADS //�� CA B PVI-3.0—OUTD—S—US—Z—A DC- MP 1: 1x8 i . mI , 1 • in. 1 n LI 240V1 I- 1 -–– 1 EGC J • . . \: I L2 ,� DC+ � LI! q N20A/2P -- GNDDD— ———- cND�- EGG Dc+ I GD+ Vstart= DEFAULT IR II A I OB i DECGEC 1� �� GC DC- `N MP 1: 1x7 j _____EC_-- ----mi---- EGC I J 1 Conduit Kit; 1' EMT N 1 — J EGC/GEC -Z CD T GEC 1/ TO 120/240V I SINGLE PHASE I UTILITY SERVICE I I Voc* = MAX VOC AT MIN TEMP POI_(1)SQUARED H MT2020 20 PV ACKFEED BREAKER /� -(1)COOPER #B—Line Meter Socket 011 A D Breoker•, 2 A 1P-20A�2P-20A 1P, 2 Spaces, Quad Tandem /� Meter Socket; 125A, 4-14AWG, Ring Type HC _(,)AW CAP; B—Line Meter Socket AccessoryC —(1 Milbank #CL200D /Ikon C1S Solid—state Single—Phose Meter; Digital B (1)CUTLER—HAMMER #DG221URB Disconnect; 30A, 240Vac, Non—Fusible, NEMA 3R —(1)CUTLER—HAMMER I!DGO3ONB Ground/Neutral Kit; 30A, General Duty(DG) 1 AWG#10, THWN-2, Black O[ F # (1)AWG 10, THWN-2, Red O PI—(2)AWG p10, PV WIRE, Black Voc* =338.27VDC Isc =8.92 ADC (1)AWG#10, THWN 2, White NEUTRAL Vmp =240 VAC Imp=14.5 MC (1)AWG/6, Stranded Bare Copper EGC Vmp =244 VDC Imp=8.36 ADC (1)Conduit Kit; 3/4' EMT .. , , . , .-(1)AWG#8, THWN-2, Green EGC/GEC,-(1)Conduit Kit:.3/4`EMT . . . (2)AWG#10, PV WIRE, Black Voc* =295.99VDC Isc =8.92 ADC O42 -(1)AWG #6, Stranded Bare Copper EGC Vmp =213.5 VDC Imp=8.36 ADC �—(1)Conduit Kit; 3/4" EMT i I CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9722198 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE MA, YILAM MA RESIDENCE Dave Williamson \‘\sla SoIaiCityBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MouNnNc SYSTEM: 12959 SW GALLIN CT NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C �'�1 PART TO OTHERS OUTSIDE THE RECIPIENTS 3.825 KW PV ARRAY ►�� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97223 - THE SALE AND USE OF THE RESPECTIVE (15) TRINA SOLAR # TSM-255PA05.18 3055 Cleaw Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET REV: DATE: San Mateoteo,, CACA 94402 PERMISSION OF SOLARCITY INC. ABB# PVI-3.O-OUTD—S-US-Z-A (971) 998-2589 THREE LINE DIAGRAM PV 5 10/2/2014 )-SOL TY F:(650)638-1029 (888)—SOL—CITY(765-2489)www.sdarcitycom Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) CAUTION (POI) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35 F Label Location: THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER-_ (DC) (INV) PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT CURRENT(Imp) A Per Code: UNGROUNDED AND INVERTER IS MAY BE ENERGIZED MAXIMUM POWER-_V NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT A Per Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION NEC 690.64.6.7 ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5 C WARNING: ELECTRIC SHOCK IF A GROUND FAULT IS INDICATED ( ) HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE • AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT _ PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC (C ): Conduit connect DISCONNECT Per Code: OPERATING VOLTAGE _ NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (D) (P01) (INV): Inverter With Integrated DC Disconnect CAUTION (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED =%tf4 3055 Cleaview Way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - OR Label Set . San Mateo,CA 94402 EXCEPT IN EQUIPMENT, WITH THE SALE AND USE OF THE OF SOLARCITY ' , So1arC�ty T:(650)638-1028 F:(650)638-1029 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (888)-SOL-CITY(765-2489)www.solarcity.com O ZS Comp Edge Zone Calculations 1 of 40 ZS Comp Edge Zone Calculations 2 of 4 Zep Sola r 5/28/13 Zep So la r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is bein down force spacing= g module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - -No„.0.111, note:use 10 psf minimum Ali:-"1",- �� Snow Calculations I&Attachment Spacing Calculations 818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing „ OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load 'F a,p P above 30 degrees. uplift spacing= FMr Ro° module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 P=qh GCN Design Snow Load 29.11 25.98 psf q =0.00256 K,K, Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 K,= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kz1= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf forst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 landsca a down orce s acrog= 11471bs in p f p x144-= 130" ortrait effective area= 21.7 ft2 39"x 32.46psf ft2 Plandscape= -30.79 psf qh= 19.25 psf Pportrait= 28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ft2 = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs landscape uplift spacing = 39"x 29.05 psf x 144 in =83" 656 lbs in portrait uplift spacing = 65"x 27.12 psf x 144 ftz = 54" I • ga ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 ZeSia r 5/28/13 5/28/13 P ZepSotar Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -1.7917 x Maximum Uplift or Down Force Pressure+ 118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273 =73" Ps=C5 Pf Roof Pitch= 31 45 degrees Pt=0.7 Ce Ct I Pg Ce= 0.9 C5= 0.71 0.45 C 1.2 portrait module spacing = -1.7917 x 32.46 psf+118.58=60" t= Pt= 22.68 22.7 psf I= 1.0 ps= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° 27° 30° Lateral 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 2921bs in landscape lateral spacing= 39"x 14.49 psf x 144 ft2 = 74" 2921bs in portrait lateral spacing= =45" 65"x 14.49 psf x 144 ft2 Portrait spacing is less than 48".Try roof pitch of 27 degrees 2921bs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed .� '' , Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules C .. aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition listed to UL 2703 of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 '"-� Seal pilot hole with roofing sealant to a more visuallya ealin s stem.SleekMount as"Grounding and Bonding System" PP 9 Y Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as •�. ` layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this system,allowing for minimal roof disturbance. •Applicable for vent spanning functions \ with sealing washer. \\1016* • Secure Leveling Foot to the Comp Mount using machine Screw • Place module 41'1N. t.t 41j1 Components _ is Ome • 5/16"Machine Screw ,ie ���� • Leveling Foot - -------------- \e% --- �� Lag Screw a • Comp Mount • Comp Mount Flashing 4- • o^ `( 0 • gill %lidoOMPAT 1,"e •:".. NaG /Be TI. 4''SolarCity January 2013 �Aco ETA LISTED SolarCity® January 2013 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE • Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-Pear(Wp) 240 245 250 255 260 Power Output Tolerance-Pear(%) 0/+3 0/+3 0/+3 0/+3 0/+3 T. • 6 JUNCTION �o Maximum Power Voltage-Ver(V) 29.7 30.2 30.3 30.5 30.7 60r Maximum Power Current-)err(A) 8.10 8.13 8.27 8.36 8.47 TSM .. PA05.18 �° "Aerru� o Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 \i°"s�A , ""olE C. Short Circuit Current-lsc(A) 8.62 8.68 8.85 8.92 9.00 tt Module Efficiency r,m(%) 14.7 15.0 15.3 15.6 15.9 TI-IE TRINAMOUNT MODULE 3 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AMI.S according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. E 0 0 is 3 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Pear(Wp) 174 178 181 184 188 Maximum Power Voltage-Ver(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE 6-0a3GHo,nasaHOLE Maximum Power Current-lel+(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME 0Aa""aE A n Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(Al 7.04 7.10 7.25 7.31 7.37 812mm ( 180 I NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. 240-260W Back View POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA • Compatible with all major BOS components and system - 17 Solar cells Multicrystalline 156.156 mm(6 inches) designs Cell orientation 60 cells(6.10) 15.9%C Module dimensions 1650.992 r 40 mm(64.95 x 39.05.1.57 inches) a Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY 1 Glass High transparency solar glass 3.2 mm(0.13 inches) One of the industry's most trusted modules Backsheet White • T • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with TrinamounT Groove O +3oJ- • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'). 10.5' 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9. 1000W/re' SmConnector Original MC4 ^75' 800W/m' -.)--- Highly reliable due to stringent quality control E 55' a 400W7m' As a leading global manufacturer • Over 30 in-house tests(UV,TC,HF,and many more) 5 4.5' 400W/„I TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements 3°° z.e W/m, Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close (NOCT) NOCT) cooperation with our partners IP Maximum system 1000V DC(IEC)/ is critical to success. With local OP 5' toe tom Som 4oe Temperature Coefficient of Pear -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina is Voltagev Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service g ( 1 to each customer in each market Temperature Coefficient of Ise 0.047%/°C and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing conditions of Trina as a strong,bankable • 130 km/hr wind load(2400 Pa) WARRANTY partner. We are committed • 900 kgsnow loadper module (5400 Pa) to building strategic,mutually 10 year Product Workmanship Warranty beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details) ; and other partners as there backbone of our shared success in CERTIFICATION f, driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY PACKAGING CONFIGURATION �' 10 Year Product Warranty•25 Year Linear Power Warranty �' \ Om span• Modules per box:24 pieces I , Trina Solar Limited www.trinasolar.com Is I Modules per 40'container:672 pieces - vloo� AddiB°nalyalue iso iti (E cmA� v • 0 90% r �Om Ti1na 5010r's 11near N arran Tr�nasolar ., CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE cludedUSING THE PRODUCT. poMPAT Tr�nasolar 02013 Trina Solar Limited.All rights reserved.Specifications included in this dotasheet are subject to rya O 80% 'w • � -^'- change without notice. Smart Energy Together Smart Energyg Together < m Years 5 10 15 20 25 Solar inverters Additional highlights: o,,, — RS-485 communication interface inverters (for connection to laptop or data A B B string logger). PVI-3.0/3.6/3.8/4.2-TL-OUTD - Integrated Arc Fault Detection and AR Interruption(-A Version). 4.IIIIIIIIIIMINW • f 3.0kW to 4.2kW . I l g ( 01 r o Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US AU Mechanical specifications r Nominal output power 3000W 3600W 3W0 3800W 4200W 3000 3300' 3300' 3600 4000' 4000' 3300 4200' ! 4200' 4200 4600' 4600' Maximum output power wattage W W W W W W W W W W W W Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V ,� H Input side(DC) Number of independent MPPT powerchannels 2 2 2 2 ..._ _. i............. .... .......... ix. Maximum usable for each channel 2000W 3000W 302 3000W Ab¢91ute•maximum voltage.(Vmex) 600V J Start-up voltage(Vstart) 200V(adj.120-350V) A Full power MPT voltage range 160-530V 120-530V 140-530V 140-530V ` k, `� - Operating MPPT voltage range 0.7 x Vstart-580V(>=90V) k ximum current(Idcmax)for both MPPT in *Tile! ' 20A 32A 32A 32A :. Maximum useale current per channel 10A 16A 16A 16A Maximum sit SR circuit current limit per 12.5A 20.OA 20.OA 20.OA channel Number of wire landing terminals per channel 2 pairs + +°" Array wiring termination Terminal block,pressure clamp,AWG10-AWG4 e Output side(AC) Grid cnnectl n type 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ 10/ Split- 10/ o 2W 0/3W 2W 2W 0/3W.. ..2W 2W 0/3W 2W 2W 0/3W 2W___. Adjustable voltage range(Vmin Vmax)(Vj 228V 264V 304V 228V „264V 304V 228V 264V 304V 228V ! 264V 304V '4 Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(I.,") 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 ARkke ......... ..... ....... ...... .. .. ........ ...... '..... '..... . .... Power factor >0.995 0.995 This familyof single-phase The high-speed MPPT offers real- Highlights: Total harmonic distortion at rated power <2% stringGrid wiring termination tYpo Terminal block Pressure clam ,AWGI O-AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energy harvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices of the property. a consistent and stable performance — The high speed and precise MPPT Anti-islanding protection Meets UL 1741/IEEE1547 requirements Over-voltage protection type Varistor,2(L. L/L, G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20Aq„° 20Ap„° 15A°„° 25A°„, 20A°„° 20Aa„° 20Aq„, 20Ap„, 20Aq.° 25Ap„° 25A.„° 25A°u° This inverter offers a dual input output power range. tracking and improved energy Efficiency ii section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency 96.9% 97% 97% 97% CEC efficiency. 96% I with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performance Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6Wgs, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <3VyeM Communkcatlon C installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display -.. 48. .. ........... orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international .RemotQmonitoring(izRS485 incl.) vSN700 Data Logger(opt.) oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Ambient air operating air operating temperature range 13°F to+140°F with derating above 122°F(50°C) example:East and West) unit able to withstand the harshest Ambient air storage temperature range -40°F to+176°F 140°C to+80°C) The dual input sections with environmental conditions. Relative humidity ........_ 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50db(A)®1m IL ,D ,D Maximum operating itutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity 1.Capability enabled at nominal AC voltage and with sufficient DC power available. for a better world'"^ P91111 IP 2 ABB Solar Inverters(Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD