Loading...
Plans (25) PITCH: 34 ARRAY PITCH:34 MP1 AZIMUTH: 160 ARRAY AZIMUTH: 160 � ° MATERIAL:Comp Shingle STORY: 2 Stories co° PITCH: 34 ARRAY PITCH:34 Y° MP2 AZIMUTH: 160 ARRAY AZIMUTH: 160 • ( M MATERIAL: Comp Shingle STORY: 2 Stories AC c PITCH: 34 ARRAY PITCH:34 © MP3 AZIMUTH:250 ARRAY AZIMUTH:250 F"--1 4111 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 34 ARRAY PITCH:34 i' D .' I MP4 AZIMUTH:250 ARRAY AZIMUTH:250 \._,' I MATERIAL:Comp Shingle STORY: 2 Stories N -P J CD (1) ■ rri \ (E) DRIVEWAY uo CD 12" ESB a CD LEGEND c o c) I dia MP1 0 (E) UTILITY METER & WARNING LABEL 0 0 () / nr' INVERTER W/ INTEGRATED DC DISCO ti ®& WARNING LABELS 10iftel °%-1 DC DISCONNECT & WARNING LABELS > 0 ' ? av MP2 AC 0 . ,_ ,,, ,llil , — ® AC DISCONNECT & WARNING LABELS I ' B 0 DC JUNCTION/COMBINER BOX & LABELS /Pitch I Front Of House 9/12 N 0 0 DISTRIBUTION PANEL & LABELS 3 IV D v -u- 1 4 IN Lc LOAD CENTER Sc WARNING LABELS I O DEDICATED PV SYSTEM METER 1 r-). STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR w e GATE/FENCE °o 0 HEAT PRODUCING VENTS ARE RED o`° i( 'I INTERIOR EQUIPMENT IS DASHED Q C) L_- ad °E. TOTAL ARRAY AREA (SF): 378 SITE PLAN H 1' W= TOTAL ROOF AREA (SF): 2241 Scale: 1/8" WOE TOTAL ARRAY AREA IS a 16.85 0 1' 8' 16' E IN II I Ill PERCENT OF TOTAL ROOF AREA ■N 1 I� s CONFIDENTIAL- THE INFORMATION HEREIN MB NUMBER: JB-9722197 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE JELINEK, GARY JELINEK RESIDENCE Brady Gilchrist o�arCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �z NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12476 SW EDGEWATER CT 5.355 KW PV ARRAY ; PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18San CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV: DATE T:(650)638-1028 Mateo, F:(650)638-1029 PERMISSION OF SOLARCITY INC. (503) 679-8482 ABB # PVI-4.2-OUTD-S-US-Z-A SITE PLAN PV 2 a 10/31/2014 (888)-soL-aTY(765-2489)www.solaraity.cam V/ (E) 2x4 (E) 2x4 PRE-MANUFACTURED TRUSS / STRUCTURE MEETS THE _ ® ` PRESCRIPTIVE REQUIREMENTS PRE MANUFACTURED TRUSS OF THE OSISC SECTION 305.4 STCRCTIIV E MEETS THE E 9 OF THE OSIENTS SC SECTIIONM305.4 r -5 , 4'-6" / 4'-5" / 4'-7"�/ 0 (E) LBW II —7" —2" • I (E) Levi B SIDE VIEW OF MP2 NTS O SIDE VIEW OF MP4 NTS MP4 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 17" PORTRAIT 48" 17" TOP CHORD 2x4 @ 24"OC ROOF AZI 250 PITCH 34 STORIES:2 ARRAY AZI 250 PITCH 34 TOP CHORD 2X4 @ 24"OC ROOF AZI 160 PITCH 34 STORIES: 2 6oT CHORD 2x4 @24"OC Comp Shingle ARRAY AZI 160 PITCH 34 BOT CHORD 2x4 @24"OC Comp Shingle • PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER / (E) 2x4 & FENDER WASHERS LOCATE RAFTER, MARK HOLE 0 PRE-MANUFACTURED TRUSS ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT 111 ZEP ARRAY SKIRT (6) — HOLE. ,/ STRUCTURE MEETS THE REQUIREMENTS (4) -2) SEAL PILOT HOLE WITH OF THE OSISC SECTION 305.4 ZEP COMP MOUNT C �— POLYURETHANE SEALANT. " 211100/741401111011 ZEP FLASHING C `tet (3) INSERT FLASHING. (E) COMP. SHINGLE ....,/ �.1 1';s� M 1 - -5 R 5'-6" '-7" (4) PLACE MOUNT. M (E) LBW (E) ROOF DECKINGVALMII =MIINSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) -.. SEALING WASHER. Go SIDE VIEW OF MP3 NTS STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES / INSTALL LEVELING FOOT WITH (6 WITH SEALING WASHER \) BOLT Sc WASHERS. MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES (2-1/2" EMBED, MIN) LANDSCAPE 72" 24" STAGGERED (E) RAFTER PORTRAIT 48" 17" S♦ STANDOFF TOP CHORD 2x4 @ 24"OC ROOF AZI 250 PITCH 34 ARRAY AZI 250 PITCH 34 STORIES: 2 1 Scale: 1 1/2" = 1' BOT CHORD 2x4 @24"OC Comp Shingle - CONFIDENTIAL— THE INFORMATION HEREIN ,q8 NUMBER: JB-9722197 0 O PREMISE OWNER: DESCRIPTION: DESIGN: ■ CONTAINED SHALL NOT BE USED FORTHE JELINEK, GARY JELINEK RESIDENCE Brady Gilchrist "r�OI���'� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12476 SW EDGEWATER CT 5.355 KW PV ARRAY ►,v,�� • ' ORGANIZATION, EXCEPTPART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD, OR 97223 CNECTION THE SALE AND USE OF ITHE N RESPECTIVEVATM (21) TRINA SOLAR # TSM-255PA05.18 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER. T:(650)638-1028 F:(650)638-1029 ABB # PVI-4.2-OUTD-S-US-Z-A (503) 679-8482 STRUCTURAL VIEWS PV 3 a 10/31/2014 (888)—SOL—CITY(765-2489)www.salarcity.com UPLIFT CALCULATIONS 10.31.2014 '��;,SolarCit�/, SleekMountTM PV System Version#39.5 Structural Design Software -Project Iceorniatiora&T Of Contents _ Risk Category: II PV wpm Type Solerr:ity SleekMottrlt" Comp Roof Comp Roof layers of Corri0 Roofing 1 Roof Slope 34° RaifterSpa0tng'' 24"04. PV System Module Orientation Landscape and Portrait PV Medial Area 370 sf PV Module Width 39" PV Mothde Length 65" Standoff(Attachment Hardware) Comp Mount Type C itethiliti fasitsidinsstuse/sums Ground Snow Load pg 25.0 psf ASCE Table 7-1 Susvoundirej„Roof Snow 100% 25.0 psf' Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf ' ASCE Eq:7.4-1 W. i Design Code ASCE 7-05 WindDesityr Method Partially/Ftp+Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposite Category C " Section 6.5.6.3 Roof Style Gable Roof `Fig.6-11B/C/D-14A/B Mean Rolf Height h 25 it Secikin 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wild Presence Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 hoortarice Factor 1 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(1(z)(Kzt)(Kd)(V^2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6.1.16/go-14A/6 Ext.lretOire CoefriCiert(Down) GCp(Down) OSO Al.8-111 14AjB Design Wind Pressure P P=RI!( ) Equation 6-22 Wind Pressure Up p(up) •17.7 pat Wind Pressure Down p(down) 16.3 psf X Yet Max Allowable Standoff Spacing Landscape 72" 39" Max MioWatAe Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Tri- 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift*Standoff T-septal -314 lbs Uplift Capacity of Standoff T-allow 500 lbs StentharkenlialdiOnatitY DO 63.1 Max Allowable Standoff Spacing Portrait 48" 65" Naxidowable Candiever Portrait 17" NA Standoff Configuration Portrait Stag•ered Max STruer Area Tab alit PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-er l -350 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff pacitY DCit W 70.09$. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9722197 O O PREMISE OWNER: DESCRIPTION: DESIGN: ‘‘‘ ■ CONTAINED SHALL NOT E USED FOR THE JELINEK, GARY JELINEK RESIDENCE Brady Gilchrist :;SO�a�C�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 12476 SW EDGEWATER CT 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS NODULES: TIGARD OR 97223 THETH ORGANIZATION, AND USEEPT OF INCONNECTION RESPECTIVE�TM (21) TRINA SOLAR # TSM-255PA05.18 3055 Mateo, CAw Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET• REV: DATE T:(650)638an-1028, F:(650)638-1029 PERMISSION OF SOLARCITY INC. 94402 '""BB (503) 679-8482 PV 4 a 10/31/2014 (888)—SOL—CITY(765-2489)www.sdacity.com ABB # PVI-4.2—OUTD—S—US—Z—A UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:Westinghouse Inv 1: DC UngroundedOR # 180498 INV 1 —(1)ABB # PVI-4.2—OUTD—S—US—Z—A LABEL: A —(21)TRINA SOLAR # TSM-255PA05.18 RGC, CGC1 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24145653 FCI Inverter; Zigbee 4200W, 240V, 96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled Underground Service Entrance INV 2 Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER n200A MAIN SERVICE PANEL 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND (E) WIRING CUTLER—HAMMER COOPER • I Vstart= DEFAULT 1 200A/2P Disconnect Meter Socket 0 ABB DC+ PVI-4.2—OUTD—S—US—Z—A DC- - G MP3 &MP4: 1x9 �� (E) LOADS A A B n u zaov I— I - EGC M DC+ II ID •�� ~ ~� I L2 �� DC- i 2 VStart= DEFAULT 25A 2P GNDGND I:1- EGC/ DC+ DC+ II III Cr• \ ) DEC 1[1.N DG - DG MP 2: 1x12 c-T-1-1 B i I GND I`__-EGC_-- -__-�-- _ EGC I V I (1)Conduit Kit; 1" EMT N 1 J EGC/GEC D z-z c� GEC -• TO 120/240V I SINGLE PHASE � UTILITY SERVICE i II I . Voc* = MAX VOC AT MIN TEMP POI —HAMM I BQC2252115 PV BACKFEED BREAKER A —(1)CUTLER—HAMMER #DG221URB AC DC POI Breaker 15A P-25A/2P-15A/1P, 2 Spaces, Quadplex Disconnect; 30A, 240Vac, Non-Fusible, NEMA 3R /1 -(1)CUTLER-HAMMER #DG030NB Ground/Neutral Kit; 30A, General Duty(DG) B (1)COOPER #B-Line Meter Socket 011 Meter Socket; 125A, 4-14AWG, Ring Type -(1)AW CAP; B-Line Meter Socket Accessory -(1)Milbank J CL200D /Itron CIS • Solid-State Single-Phase Meter; Digital 3 -(1)AWC #10, THWN-2, Block (2)AWG #10, PV WIRE, Black Voc* =380.56VDC Isc =8.92 ADC O -(1)AWG #10, THWN-2, Red O -(1)AWG #6, Stranded Bare Copper EGC Vmp =274.5 VDC Imp=8.36 ADC (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 MC (1 Conduit Kit; 3/4" EMT . . . . . . .-(1)AWG #S,.TI{WN-2,_Green. _ _ EGC/GEC.7(1)Conduit.Kit;.3/4".EMT, . . . . —(2)AWG #10, PV WIRE, Black Voc* =507.41 VDC Isc =8.92 ADC O 2'2-(1)AWG #6, Stranded Bore Copper EGC Vmp =366 VDC Imp=8.36 ADC (1)Conduit Kit; 3/4" EMT CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-97221 9 7 00 PREMISE OWNER: DESCRIPTION: DESIGN: �� SolarCityCONTAINED SHALL NOT BE USED FOR THE JELINEK GARY JELINEK RESIDENCE Brady Gilchrist ENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12476 SW EDGEWATER CT 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 SHEET: REV: DAA s3a Mateo,CA 3055 Waygearview sa02 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME1:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER' (503) 679-8482 PV 5 a 10/31/2014 (888)-SOL-CITY(765-2489)www.sdarcitycam ABB # PVI-4.2-OUTD-S-US-Z-A THREE LINE DIAGRAM ELECTRICAL CALCULATIONSModule: 21 TRINA SOLAR#TSM255 ZEP 232.2 Inv Power WPIC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 ABB PVI 4.2 S AFCI 0.96 4600 4681.15 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) Module: Imp(A) Max.Length(ft) Wire Inverter 2: String: 8.36 75 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 150 *0.001240hms) / 301.4742 0.69 Inverter 3: Branch: 8.36 50 AWG_10 at Max Ave Hi:87 deg F . Module: Vdrop= (8.36 * 100 *0.001240hms) / 301.4742 0.46 Inverter 4: Total voltage drop in DC conductors= 1.15 Inverter: 8.36 20 AWG_10 at 240V ' Vdrop= (8.36 *40 *0.0012 Ohms) / 240 V 0.1672 Total: 21 Modules Total Inv Pwr: 4600 4681.15 PTC Combined: 0 0 AWG#10 at 240V Photovoltaic Module Electrical Specifications: Total STC: 5355 Vdrop= (0 *0 0.0012 Ohms) / 240 V 0 Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.17 Isc: 8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.31 Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc: 4.1924 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI-4.2-S AFCI 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 12 TRINA SOLAR#TSM-255 ZEP Min Vmp at Max Temp: 301.47 12 modules per series string 9 modules per series string Voc= 452.4 Voc= 452.4 V Voc= 339.3 V Max Voc at Min Temp: 507.41 Vmp= 366 Vmp= 366 V Vmp= 274.5 V Inverter Max Vdc Input: 600 Isc= 8.92 Isc= 8.92 A Isc= 8.92 A Max String Size: 14 Imp= 8.36 1-way wire length: 75 Imp= 8.36 A Imp= 8.36 A Icont= 11.15 Art 690.8(A)(1) Icont=, 11.15 A Icont 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG#10 PV Wire 2.a Conductor 1: AWG#10 Conductor 2: AWG#10 Icont*1.25=(Amps) 13.94 Conductor 1 Conductor 2 30 deg C ampacity= 25 Icont*1.25=(Amps) 13.94 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 25 25 Start ampacity 25 2.b Icont=(Amps) 11.15 11.15 - Temperature derate(%=F) 0.76 Start ampacity 25 25 Conduit fill derate(%=#) 0.8 Temperature derate(%=F) 0.76 0.76 Derated ampacity 15.2 Conduit fill derate(%=#) 0.8 0.8 1.c Derated ampacity 15.2 15.2 Icont*1.25=(Amps) 0 2.c Term 1 Term 2 Ampacity 25 Temp table 90 90 1.d Icont*1.25=(Amps) 0 Icont*1.25=(Amps) 13.94 13.94 Ampacity 25 25 OCP Size= 15 Inverter Type A Output 2.d OCP Size= 15 15 ABB PVI-4.2-S AFCI 1 way wire length: 10 ft Combined Inverter Output Icont= 20 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 25 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 25 Art 240.6(A) (cont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG#10 THWN-2 at 90 deg C:Table 310.16 (cont=(Amps) Icont*1.25=(Amps) 25 4.a Icont*1.25=(Amps) 25 Art 690.8(B)(1) 30 deg C ampacity= 30 OCP size= 25 Art 240.6(A) 3.c Icont=(Amps) 20 4.b Conductor: Wire Size: AFteiV0119 at 90 deg C:Table 310.16 Start ampacity 30 Icont*1.25=(Amps) 25 Temperature derate(%=F) 0.91 30 deg C ampacity= 30 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 20 Derated ampacity 27.3 Start ampacity 30 3.d Icont*1.25=(Amps) 25 Temperature derate(%=F) 0.91 Ampacity 25 Conduit fill derate(%=#) 1 Derated ampacity 27.3 4.d Icont*1.25=(Amps) 25 Ampacity 25 J B-9 7221 9 7 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMAl10N HEREIN JOB NUMBER: 4\ti, CONTAINED SHALL NOT BE USED FOR THE JELINEK, GARY JELINEK RESIDENCE Brady Gilchrist �:,;SD�a�C�ty. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ver NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12476 SW EDGEWATER CT 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV DATE: San Mateo, CA 94402 '""�' (503) 679-8482 PV 6 a 10 31 2014 ( �s«�pnt65829i�)ww 'r°tya«n PERMISSION OF SOLARCITY INC. ABB # PVI-4.2-OUTD-S-US-Z-A ELECTRICAL CALCULATIONS Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC - A (AC) (P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC) (INV) • DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- A (DC) (INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp)_ Per Code: MAY BE ENERGIZED MAXIMUM POWER--v NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEM-V Label Location: VOLTAGE(Voc) WARNING (AC)(POI) SHORT-CIRCUIT Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: ' TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.B.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC _ (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit I (INV): Inverter With Integrated DC Disconnect CAUTION (D) (P01) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (POI): Point of Interconnection . CONFIDENTIAL— NE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR •��.�j 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �` a San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set ..-„,►� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE "•�Ofatt' (888)-:06-0)63(765-2489)www.so102y.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. f ZS Comp Edge Zone Calculations 1 of 40 ZS Comp Edge Zone Calculations 2 of 4 Zep S o la r 5/28/13 Zep S o la r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing = calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load • checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads design load landscape= 9.62 17.32 17.32 psf Uplift= 656 lbs Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - -Ro j0010111 note:use 10 psf minimum � � Snow Calculations Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing a OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes 41V. '01' �e above 30 degrees. Allowable Uplift Load �,, 10 ROG�� uplift spacing = module length or width x design load EXPIRES. 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 Design Snow Load 29.11 25.98 psf p=gh GCN qh=0.00256 KZ Ka Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof KZt= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+O.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 lscape effective area= 13.0 ft2 GCN portrait= -1.5 11471bs in landscape down force spacing = 39"x 32.46psf x 144 fta = 130" ortrait effective area= 21.7 ft2 Plandscape= -30.79 psf qh= 19.25 psf pportralt= 28.87 psf 1portrait down force spacing = 65"x32.46ps f x 144 in = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = 39"x 29.05 psf x 144 ft2 = 83" 656 lbs in portrait uplift spacing = x 144 65"x 27.12 psf f= 54" ft2 0 ZS Comp Edge Zone Calculations 3 of 4 5/28/13 f ZS Comp Edge Zone Calculations 4 of 4 5/28/13 ZepSolar ZepSotar Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing = module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing = -1.4545 x 32.46 psf+120.7273 = 73" Ps=Cs pf Roof Pitch= 31 45 degrees pf=0.7CeCtlpg Ce= 0.9 C5= 0.71 0.45 portrait module spacing = -1.7917 x 32.46 psf+118.58=60" Ct= 1.2 pf= 22.68 22.7 psf I= 1.0 PS= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" T (snow load spread over the length of the rafter) 30° 27° ' 30° Lateral 74" 48" 45' - Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 2921bs in landscape lateral spacing = 39"x 14.49 psf x 144ft2 = 74" 2921bs in portrait lateral spacing = 65"x 14.49 psf x 144 f't2 = 45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 2921bs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and 4Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and 4• Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 / • Seal pilot hole with roofing sealant as"Grounding and Bonding System" Insert CompMount flashingunder upper to a more visually appealing system.SleekMount � pp utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as • layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs,effectively eliminating the • Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition • Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions • Secure Leveling Foot to the Comp Mount '" using machine Screw • Place module I Components 4-1,_ets. t ' � • 5/16"Machine Screw • i • Leveling Foot �.� Screw Lag • Comp Mount Comp Mount Flashing sem' 0 0® • .; --iiiii101\ 0) Let �d�a^ • � � T E{Y • t SolarCity® January 2013 pc� ETA LISTED ".'MSolarCityo January 2013 eMPP TSM-PA05.18 TRINAMOUNT H WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 • 941mm Peak Power Watts-Pmnx(Wp) 240 245 250 255 260 Power Output Tolerance Po rn(%) 0/+3 of+3 0/+3 [30% o Maximum Power Voltage-Vase(V) 29.7 30.2 30.3 30,5 30.7 MaimumPowerCurrent-kin'(A ; 8 . 83 8.27 8.36 8 47• NAOASPLAn• Open Circuit Voltage-Voc(V) 37.337.537.637.737.9iNsrnuiNc NoLETsiiiii ,.. pA05 Short CircuitCurrent-lsc(A) .6: 8 ' : 892 //.00 1 8THE TRINAMOUNT MODULE Module Efficiency n.,(%) 14.7 15.0 15.3 15,6 : 15.9 STC:Irradiance 1000 w/m',Cell Temperature 25°C,Air Mass AMLS according to EN 60904-3. E Average efficiency reduction of 4.5%at 200 W/mz according to EN 60904-1. E 3 vi 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 E PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-Pmnx(Wp) 174 178 181 184r. 188 '''''''''''''''''''''''''''''''' "Ilii'''' "E'LL:". 111;4i1Hiti1iiiii1.11,:iiii:.-10iitiit1 tvkeaximumPowerVoltoge-Vnw'(V) 26.6 26.8. 27.0 27.2 27.4 ,; • 6-043 GROUNDING HOLE alai VIAC3.lf 044,kg Maximum Power Current Itis,(A) 6.55 6.64 6.70 6.77 6.86 A A .1411131!1*-44*4TRINAMOUNT FRAME ,z ORniB:OXB Open Circuit Voltage(V)-Voc(V)' 34.1 34.2 34.3 34.4 34,6 ' ; :: Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 812mm 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. -260 .:' Back View f #11 �= (}�G MECHANICAL DATA Our most versitile product 1 • Compatible with all major BOS components and system - Solar cells Multicrystalline 156•156 mm(6 inches) 11 e g s .. d Si n 'cell'Orientation d0 cells(b=igf 7 Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) >; ' ,ii d Weight 18.6:kg(41.0 lbs) MAXIMUM EFFICIENCY _(1 Glass High transparency solar glass 3.2 mm(0.13 is B„ One of the industry's most trusted modules FFrame a Black Anodized Aluminium Alloy withTrinamountGroove t (fe I • Over 2 GW sold across all major global markets Fieldproven performance I V CURVES OF PV MODULE ISM 245 PA05 18 Cables bl 4 0 • r n e ology cable mm'(0.006 inches'), J Box IP 55 or IP 67 rated POWER O TPUF GUARANTEE /m Photovoltaic Techn l0. 1100 mm(43 3T inches) ...: .. qro r w z _. B W connectors Original MC4 '? :. ... Highly reliable due to stringent quality control Q bW 600W/m a,5.00 As a leading global manufacturer ® • Over 30 in-house tests (UV,TC, HF,and many more) 4.W 400W/m> TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements 200W/rM Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close z.m Temperature(NOCT) cooperation with our partners 1.. .__.....__.. ._,,...-_.-�, Maximum System 1000V DC)IEC)/ o°D Temperature Coefficient of P..A. -0.43%/°C Voltage b00V DC(UL) is critical to success. With local o.W lo.°' 20 W 30� 40°' presence around the globe,Trina is Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able toprovide exceptional service Voltage(V) a p Temperature Coefficient of Isc : 0.047%/C to each customer u each market Certified to withstand challenging environmental and supplement our innovative, ;� g g reliable products with the backing '17 conditions of Trina as a strong,bankable cr6g • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) to year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details( and other partners as the backbone of our shared success in CERTIFICATION •,,,,:l driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY ( �C�:y� PACKAGINGCONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty \ R, � G. Modules per box:24 pieces 3 Trina Solar Limited www,trinasolar,com l00% ISO ;�� E ®5 Pv-7 VOLE Modules per 40'container.672 pieces 0 4ddrlronal value fi I B o 90% OM Trlaa$Olars hgeoj warranty • CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. QpaMPArje� (` /'yr^ a c 2013 Trina Solar Limited.• All rights reserved.Specifications included in this datasheet are subject to W ,� Tranasola c9 80% trinasola change without notice g v Smart Energy Together Years 5 o s 20 25 Smart Energy Together p°unrrntIs ° industry skanciard ll Trina Solar Additional highlights: .a- c Solar inverters – RS-485 communication interface (for connection to laptop or data logger). – Integrated Arc Fault Detection and A 1 • Interruption(-A Version). _—._ . . t',T 0 V Technical data and types 4.7.r1."1,- HI! -':17 '' Type code PVI 3 0 OUTD US PVI 3 6 OUTD US PVI 3 8 OUTD US PVI 4 2 OUTD US AUnq i Jpiti t1,5l: . . .. Nominal output power 3000W 3600W W 3800W 4200W 3300 Maximum output power wattage 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' 4200 4600' 4600' W W W W.... W W W W W W W...........w ( Rated.rid AC volta e 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V inpvtiSi ® - .. :::....., . a8 e Number of independent MPPT channels 2 2 2 2 �,. Maximilm usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum voltage(Vmax) 600V Fulll power MPPT voltage range 160-530V 120-530V 200V(adj.120-350V)140-530V 140-530V �. $' '° 0 eratin MPPT voltage range 0 7 x Vstart 580V > 9oV) L e Maximum current Idcmax for both MPPT in 20A 32A 32A 32A 3 parallel, Maximum usable current per channel 10A 16A 16A 16A hannelm short circuit current limit per 12.5A 20 0A 20.OA 20.0A Number of wire landing terminals per channel 2 pairs x .. ,. ........ . Arraayy wiring termination Terminal block,pressure clamp,AWG10 AWG4 " 1(d/ Split- 10/ 10/ Split 10/ 10/ Split- 0/10/ 1Split- 1G/ Grid connection type 2W 0/3W2W 2W 0/3W . 2W 2W 0/3W : 2W 2W 0/3W 2W �'�'� �.+ Adjustable voltage range(Vmin-Vmax)(V) 183 ........211.. 244- 183- 211- 244- 183- 211- 244- 183-..... 211- 244-.... 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V264V 304V Grid frequency 60Hz Adjustable grid frequency range 57-60.5Hz Maximum current(I° a,) 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 ................ARMS.........ARMS.......ARMS..,......ARMS... ....ARMS.........ARMS ......ARMS.........ARMS.......ARMS........ARMS...... ARMS.......ARMS..... Power factor >0.995 Total harmonic distortion at rated power <2% This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10 AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output tnput peateti tl:". ss . Reverse polarity protection Yes number of rooftop solar panels energyharvesting. grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high – Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. f)utput(rPtecUpndeviees of the property. a consistent and stable performance – The high speed and precise MPPT Anti-islandingevageprotection Meets UL 1 2(L -L/7 i- )rements • Over-voltage protection type Varistor,2(L.-L/L -G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating •20ARM,, 20A,,,,,, 15A,,,,,G 25AR,,, 20AR,,,,G 20AR,,,G 20Ae„° 20AR,,,, 20ARM 25AR,,,° 25AR. 25ARM,,, This inverter offers a dual input output power range. tracking and improved energy Eftici9l y section that processes two strings The transformerless operation gives the harvesting. Maximum efficiency96 9/ 97% 97% 97% , CEC efficiency 96% with independent Multiple Power Point highest efficiency of up to 97.0%. – Outdoor NEMA 4X rated enclosure Qparatie P0001" pane Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6WRti,s This is especially useful for rooftop the inverter suitable to low power environmental conditions. Stand-by consumption <awRM installations with two different installations with reduced string size. – Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display orientations from two sub-arrays This rugged outdoor inverter has been in compliance with international Remote monitoring(1xRS485 Incl.) VSN700 Data Logger(opt.) >MfiYi[PrNriettral.it ....: oriented in different directions.(For designed to be a completely sealed Standards(-S Version). Ambient air operating temperature range 13°F to+140°F with derating above 122°F(50°C) example:East and West) unit able to withstand the harshest Ambient air storage temperature range I -40°F to+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity aE 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)@lm „ ,II ,I Maximum operating altitutde without derating 6560 ft(2000 m) optimal energy harvesting condition. Power and productivity 1 Capability enabled at nominal AC voltage and with sufficient DC power available. for a better world'" I %•W1W 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTO