Plans (28) PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 30 ARRAY PITCH:30 MP2 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 30 ARRAY PITCH:30 MP3 AZIMUTH:90 ARRAY AZIMUTH:90 MATERIAL:Comp Shingle STORY: 2 Stories ■ 0 * (4. _ 12- FSB C , � — C 0 Q C I e 0 LEGEND I — Un-Locked Gated ,-;'• ,.., I 0 (E) UTILITY METER & WARNING LABEL ° Lo&ed ate �MP1 ® ® INVERTER W/ INTEGRATED DC DISCO DC IN LC & WARNING LABELS I� AC DC DC DISCONNECT & WARNING LABELS P'ch OJ [5-1AC DISCONNECT Se WARNING LABELS 40IN � '� DHH 0 OO DC JUNCTION/COMBINER BOX & LABELS ( " .. LI --- * • \ QD DISTRIBUTION PANEL Sc LABELS Lc LOAD CENTER Sc WARNING LABELS ODEDICATED PV SYSTEM METER Front Of House r,.) STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR — GATE/FENCE 4, 0464 40 1p1,6 .40416.,rf 0511 Q HEAT PRODUCING VENTS ARE RED i Al kti4k Pi* ii se:4 I1 `i INTERIOR EQUIPMENT IS DASHED (E)DRIVEWAY L`�J SITE PLAN N 144,404tAik p ,,,,, TOTAL ARRAY AREA (SF): 378 Scale: 3/32" = 1' Aga lir tie 12345 SW Quail Creek Ln TOTAL ROOF AREA (SF): 2517 TOTAL ARRAY AREA ISN 15 w `+ EO 1' 10' 21' PERCENT OF TOTAL ROOF AREA aI.I S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: PREMISE OWNER: DESCRIPTION: DESIGN: JB-9722224 00 CONTAINED SHALL NOT BE USED FOR THE LOPRESTI, SHELLEY LOPRESTI RESIDENCE Derrick Olds Nb `N'!- BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: /, C I rrl+ . NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12345 SW QUAIL CREEK LN 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES THE SALE AND EXCEPTEOF THESP CT1VE TIGARD OR 97223 IREWITH (21) TRINA SOLAR # TSM-255PA05.18 3055 ew Way • ITT SOLARCITY EQUIPMENT, WITHOUT THE WREN INVERTER: PAGE NAME SHEET: REV: DAIS: Mateo, CA T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABBE PVI-3.O-OUTD—S—US-Z-A (971) 322-5651 SITE PLAN PV 2 10/9/2014 (888)—SOL—CITY(765-2489)www.salarcity.aam \/ Ill* (E) 2x4 (E) 2x4 — ® PRE—MANUFACTURED TRUSS 0 PRE MANUFACTURED TRUSS STRUCTURE MEETS THE /� STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS PRESCRIPTIVE REQUIREMENTS 9 OF THE OSISC SECTION 305.4 4911OF THE OSISC SECTION 305.4 1' !.1 5'-3" 5'-9" 1I,,1' , 7'-3" / 6'-6" / 6'-6" (E) LBW + (E) LBW SIDE VIEW OF MP2 NTS A SIDE VIEW OF MP1 NTS 6 MP2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 18" PORTRAIT 48" 20" ROOF AZI 180 PITCH 22 TOP CHORD 2x4 @ 24" OC ROOF AZI 270 PITCH 30 STORIES: 2 TOP CHORD 2x4 @ 24" OCARRAY AZI 180 PITCH 22 STORIES: 2 ARRAY AZI 270 PITCH 30 BOT CHORD 2x4 @24" OC Comp Shingle BOT CHORD 2x4 @24" OC Comp Shingle — PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) \) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. �!_�� IL. FHM ■1�1�1�1�=i�1�11�I�1IrN ---- ZEP ZEP FLASHING C ,I T S_ (\) INSERT FLASHING. (E) COMP. SHINGLE vmommi; imomomPP-- Co PLACE MOUNT. (E) ROOF . ZEP CO (5) LAG BOLT WITH 5/16" DIA STAINLESS (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) - (E) RAFTER STANDOFF Scale: 1 1/2" = 1' JB-9722224 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIALIED — THE INFORMATION ESEDFORHN JOB NUMBER: 1:13 SoIarCit •CONTAINED SHALL NOT USED THE LOPRESTI, SHELLEY LOPRESTI RESIDENCE Derrick Olds BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 12345 SW QUAIL CREEK LN 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS Moa, ' TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.183055 Clean/ low 638028ow Way - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN A 94402 INVERTER: PAGE NAME SHEET: REV: DATE: Mateo, F:(650)638-1029 PERMISSION OF SOLARCI Y INC. ABB# PVI-3.0–OUTD–S–US–Z–A (971) 322-5651 STRUCTURAL VIEWS PV 3 10/9/2014 (886)—SGL—CITY(765-2469)www.solarcity.com UPLIFT CALCULATIONS 10.09.2014 .''m? SolarCit" SleekMountTM PV System Version#39.5 `'`' Structural Desian Software Project Information&Table Of Contents Risk Category: II PV System Type SolarCity SleekMounr Comp Roof Comp Roof Layers of Camp Roofing 1 Roof Slope 30° Rafter Spadng 24"O.G. PV System Module Orientation Landscape and Portrait PV Module Area 370 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof five/Snow Loads Ground Snow Load pg 25.0 psi 'ASCE Table 7-1 Surrounding Roof Snow 100% 2SA/psf ' ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psi 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C ' Section 6.5.6:3 Roof Style Gable/Hip Roof 'Fig.6-13B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V'2)(I) Equation 6-15 18.6 psi Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.e-11B/C/o-14A/B Ext Pressure Coefficient(Down) GCP(Down) 0.: Fig.6- 1B/C/D-14A,IB Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Prune Up p(up) -17.7 psi Wind Pressure Down p(down) 16.3 psf Allowable Standoff Spacings X-Direction V-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psi Net Wind Uplift at Standoff 7-actual -314 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capat ty DCR 6/8% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 18* NA Standoff Configuration Portrait Staggered - Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psi Net Wind Uplift at Standoff 7-actual -348 lbs Uplift Capacity of Standoff T-allow 500 lbs Starndoff Demand/Capadty DCR 69.7% JB-9722224 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONFIDENTIALIEDA THE INFORMATION USED FOR N JOB NUMBER: ��.,,C Ian( i CONTAINED SHALL NOT BE USED THE LOPRESTI, SHELLEY LOPRESTI RESIDENCE Derrick Olds �_1. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: A.4 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12345 SW QUAIL CREEK LN 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: REV: DATE: s30 Mateo,CA 94402 - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: L(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCFIY INC. ABB# PVI-3.0—OUTD—S—US-7-A (971) 322-5651 UPLIFT CALCULATIONS PV 4 10/9/2014 (888)-soL-aTY(765-2489)www.soIarcity.cam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) UFER AT PANEL Panel Number: Inv 1: DC Ungrounded INV 1 -(1)ABB#PVI-3.o-OUTD-s-us-Z-A -(21)TRINA SOLAR # TSM-255PA05.18 OR # 180498 WITH IRREVERSIBLE CRIMP Meter Number:24155031 Inv 2: DC Ungrounded FCI Inverter, Zigbee 3000W, 240V, 96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 -(1)ABB#PVI-3.0-OUTD-S-US-Z-A FCI Inverter, Zigbee 3000W, 240V, 96% Voc: 373 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E 200A MAIN SERVICE PANEL E5 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND (E) WIRING CUTLER—HAMMER COOPER BRYANT Disconnect Meter Socket ®(N) 125A Load Center ® ABB Q DC+ Vstart = DEFAULT 200A/2P PVI-3.0-OUTD-S-US-Z-A Dc- MP 1: 1x7c_117 In -4� (E) LOADS A B C 20A/2P I 240 I I— I EGC • �. , ■ ■--I �-• • •� I I+ I� I N _,� DC- I 0 Vstart= DEFAULT 40A/2P — EGC DC+ DC+ - -- u i� R q I ___-� GND - - -- GND v-, o --— DEC ---�❑N DG A DG MP 1: 1x8 I I ii E I I • • B I I Z I I GND I EGC ____ __ - _ V EGC 11-1 ADJUST MIN. ACTIVATION VOLTAGES! (1)Conduit Kit; 1" EMT N I Inverter 2 PAR J EGC/GEC -� I ® ABB z-z PVI-3.0-OUTD-S-US-Z-A CD 20A/2P T GEC _n_414._. Li 290V L2 —46 TO 120/240V i i ,. ~ N — 3 SINGLE PHASE I L-_L,` EGC/ --- ._—DC+ DC+ Vstart= 181V U11UTY SERVICE I DEC -1� N —.� DC- DC- MP 2: 1x6 GND I----EGC- - ---- --- -- 1 EGC J Voc* = MAX VOC AT MIN TEMP POI—(1)CUILER—HAMM #BR240 PV BACKFEED BREAKER A —(1)CUTLER—HAMMER #DG222UR8 C —(1)BRYANT#BR816L125RP Breaker, 40A P, 2 Spaces Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R AC Load Center, 125A, 120/240V, NEMA 3R DC -(1)CUTLER-HAMMER M DG100NB -(2)CUTLER-HAMMER #BR220 Ground/Neutral Kit; 60-100A, General Duty(DG) Breaker, 20A/2P, 2 Spaces B (1)COOPER #B-Line Meter Socket 011 Meter Socket; 125A, 4-14AWG, Ring Type -(1)AW CAP; B-Line Meter Socket Accessory -(1)Milbank !CL200D /Itron CIS Solid-State Single-Phase Meter; Digital ©—(1)AWG —(1)AWG #8, THWN-2, Block (1)AWG #10, THWN-2, Black (2)AWG #10, PV WIRE, Black Voc* =295.99VDC Isc =8.92 ADC .-"-(1)AWG #8, THWN-2, Red ®II-(1)AWG #10, THWN-2, Red ® -4-(1)AWG #6, Stranded Bare Copper EGC Vmp =213.5 VDC Imp=8.36 ADC • (1)AWG#8, THWN-2, White NEUTRAL Vmp =240 VAC Imp=29 AAC I (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 MC • (1)Conduit Kit; 3/4" EMT -(1)AWG #8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4" EMT . -(1)AWG #8,.TH.WN-2,.Creep. . . ECC/GEC.-(1)Conduit.Kit;.3/4" EMT. . . . . . . . . . (2)AWG #10, PV WIRE, Block Voc* =338.27VDC Isc =8.92 ADC (1)AWG #10, -2, Black O IJ�(1THWN )AWG 0, THWN-2, Red ®• (1)AWG #6, Stranded Bare Copper EGC Vmp =244 VDC Imp=8.36 ADC (1)Conduit Kit; 3/4" EMT • (1)AWG #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC (2)AWG #10, PV WIRE, Black Voc* =253.71 VDC Isc =8.92 ADC -(1)AWG #8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4" EMT O I LFI-(1)AWG #6, Stranded Bare Copper EGC Vmp =183 VDC Imp=8.36 ADC 6666 (1)Conduit Kit; 3/4"EMT JB-9722224 0 0 PREMISE OWNER: DESCRIPIION: DESIGN: CONFIDENTIALIED - THE INFORMATION USEION FORHETHEREIN JOB NUMBER: \,'`SoIarCIt CONTAINED SHALL NOT BE USED ,HE LOPRESTI, SHELLEY LOPRESTI RESIDENCE Derrick Olds .._ , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ..: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12345 SW QUAIL CREEK LN 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD, OR 97223 THE SALE AND EXCEPT INCONNECTION RESPECTIVE�TM (21) TRINA SOLAR # TSM-255PA05.183055 Clear ew Way - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN MVERTER: PAGE NAME SHEET: REV: DATESan T:(650)638 Mateo, CA 94402 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0-OUTD-S-US-Z-A (971) 322-5651 THREE LINE DIAGRAM PV 5 109/2014 (888)-SOL-CITY(765-2489)www.solarcity.com ELECTRICAL CALCULATIONSModule: 15 TRINA SOLAR#TSM255 ZEP 232.2 Inv Power WPIC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 ABB PVI 3.0 S AFCI 0.96 3300 3343.68 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) Module: 6 TRINA SOLAR#TSM-255 ZEP 232.2 Imp(A) Max.Length(ft) Wire • Inverter 2: 1 ABB PVI-3.0-S AFCI 0.96 3300 1337.472 String: 8.36 70 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 140 *0.001240hms) / 200.9828 0.83 Inverter 3: Branch: 8.36 50 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 100 *0.001240hms) / 200.9828 0.59 Total voltage drop in DC conductors= 1.41 Inverter 4: Inverter: 8.36 10 AWG_10 at 240V Vdrop= (8.36 * 20 *0.0012 Ohms) / 240 V 0.0836 Total: 21 Modules Total Inv Pwr: 6600 4681.15 PTC Combined: 16.72 20 AWG_8 at 240V Photovoltaic Module Electrical Specifications: Total STC: 5355 Vdrop= ( 16.72 *40 0.00078 Ohms) / 240 V 0.21736 ' Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.3 Isc: 8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.72 Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc:L 4.1924 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 50 Voc Correction Factor: ABB PVI-3.0-S AFCI 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 8 TRINA SOLAR#TSM-255 ZEP 8 modules per series string 7 modules per series string Voc= 301.6 Min Vmp at Max Temp: 200.98 Voc= 301.6 V Voc= 263.9 V Vmp= 244 Max Voc at Min Temp: 338.27 Vmp= 244 V Vmp= 213.5 V Isc= 8.92 Inverter Max Vdc Input: 600 Isc= 8.92 A Isc= 8.92 A Max String Size: 14 Imp= 8.36 Imp= 8.36 A Imp= 8.36 A Icont= 11.15 Art 690.8(A)(1) 1-way wire length: 70 Icont= 11.15 A Icont= 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 Conductor 2: AWG_10 (cont*1.25=(Amps) 13.94 Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont*1.25=(Amps) 13.94 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icont=(Amps) 11.15 11.15 Temperature derate(%=F) 0.76 Start ampacity 40 40 Conduit fill derate(%_#) 1 Temperature derate(%=F) 0.76 0.76 Derated ampacity 30.4 Conduit fill derate(%=#) 0.8 0.8 1.c Derated ampacity 24.32 24.32 Icont*1.25=(Amps) 13.94 2.c Term 1 Term 2 Ampacity 40 Temp table 75degC 75degC Icont*1.25=(Amps) 13.94 13.94 1.d Icont*1.25=(Amps) 13.94 Ampacity 35 35 OCP Size= 15 Inverter Type A Output 2.d OCP Size= 15 15 ABB PVI-3.0-S AFCI 1 way wire length: 10 ft Combined Inverter Output (cont= 14.5 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 18.12 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 20 OCP Size= 20 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont*1.25=(Amps) 18.12 4.a Icont*1.25=(Amps) 36.25 Art 690.8(6)(1) 30 deg C ampacity= 40 OCP size= 40 Art 240.6(A) 3.c Icont=(Amps) 14.5 4.b Conductor: AWG_8 THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont*1.25=(Amps) 36.25 Temperature derate(%=F) 0.91 30 deg C ampacity= 55 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 29 Derated ampacity 36.4 Start ampacity 55 3.d Icont*1.25=(Amps) 18.12 Temperature derate(%=F) 0.91 Ampacity 35 Conduit fill derate(%=#) 1 Derated ampacity 50.05 4.d Icont*1.25=(Amps) 36.25 Ampacity 50 CONFIDENTIAL J B9 722224 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: CONATHE IN \\`!p CONTAINED SHALL NOT BORUSBE USEDION FORRHEREIN JOB NUMBER: -THE LOPRESTI, SHELLEY LOPRESTI RESIDENCE Derrick Olds �. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ��, SolarCit ` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 12345 SW QUAIL CREEK LN 5.355 KW PV ARRAY PART TO OTHERS OUTSIDE NE RECIPIENTS MODULES TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Clearview Way NE SALE AND USE OF NE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: REV: DALE San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT NE WRITTEN INVDt1ER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB# PVI-3.0-OUTD-S-US-Z-A (971) 322-5651 ELECTRICAL CALCULATIONS PV 6 10/9/2014 (888)-SOL-CITY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC - A (AC) (P01) CAUTION (P01) • Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC) (INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- A (DC) (INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp)_ Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER- v NEC 690.53 POINT VOLTAGE(Vmp) Label Location: MAXIMUM SYSTEM V VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT A Per Code: CURRENT(Ise) ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.6.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC) (INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING:ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC - (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE V (CB): NEC 690.14.C.2 CB : Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D)(POI) (LC): Load Center Per Code: (M): Utility Meter PHOTOVOLTAIC SYSTEM NEC 690.64.6.4 CIRCUIT IS BACKFED (P01): Point of Interconnection CONFIDENTIAL— NE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 014 `et' 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ..= - ° San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set 4'i,,i T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /y So la� (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (� ZS Comp Edge Zone Calculations 1 of 40 ZS Comp Edge Zone Calculations 2 of 4 Zep S o to r 5/28/13 ZepSotar 5/28/13 • This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing = calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs 'Ro 04 note:use 10 psf minimum .........„.„..41410.w.-- Snow Calculations Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing „ OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes <ti '� above 30 degrees. Allowable Uplift Load ve. ro, C� uplift spacing = MY Ro module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 p= qn GCN Design Snow Load 29.11 25.98 psf (snow load spread over the length of the rafter) chi=0.00256 KZ K, Kd V2 I Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 0+5= 31.16 25.10 psf Gable/Hip Roof K,= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 lscape effective area= 13.0 ft2 GCN portrait= 4.5 landscape down force spacing = 39"x132.46 s x 144 r = 130" ortrait effective area= 21.7 ft2 p f f z Plandscape= -30.79 psf Oh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ftz = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in ' landscape uplift spacing = 39"x 29.05 psf x 144 ftz = 83" 656 lbs in . portrait uplift spacing = 65"x 27.12 psf x 144 ftz = 54" t ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 ZepSaar 5/28/13 Zep S a la r 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing = -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing = -1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing = module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273 = 73" p5=C5 pf Roof Pitch= 31 45 degrees pf=0.7CeCtlpg Ce= 0.9 C5= 0.71 0.45 portrait module spacing = -1.7917 x 32.46 psf+118.58 = 60" Ct= 1.2 pf= 22.68 22.7 psf I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° Lateral 30° 27° 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.75S 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing = 39"x 14.49 psf x 144 f= 74" tz 292lbs in portrait lateral spacing = 65"x 14.49 psf x 144 f=45" t2 Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ftz =48" • SolarCity SleekMountT"' - Comp SolarCity SleekMountT'" - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed "' Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules .. `---- I aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 '� mounting clamps, combined with the addition • Interlock and Ground ZepETL listed to UL 1703 Seal pilot hole with roofing sealant of array trim and a lower profile all contribute to a more visually appealing system.SleekMount as"Grounding and Bonding System" • Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as \-- layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance I \ • Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. P system, allowing for minimal roof disturbance. •Applicable for vent spanning functions • Secure Leveling Foot to the Comp Mount using machine Screw • Place module c 11) Components %f _ • 5/16"Machine Screw • 411/I S Leveling Foot . • Lag Screw Comp Mount Comp Mount Flashing O O® 0 • *--(•— I,II .`m\I IP • y AAJAR �oMPATiq I. ,Afes" SoiarCity. ry ; j co LISTED ;v° Soiar1ity.January 2013 e January 2013 .. TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941 mm Peak Power Watts-PMA.(Wp) 240 245 250 '. 255 260 _ Power Output Tolerance-PMA.(%) 0/+3; 0/+3 0/+3 0/+3 0/+3 0 r iuNrnoN o Maximum Power Voltage-VMP(V) 29.7 30.2 30.3 30.5 30.7 BO% 8 _ Maximum Power CurrentIMPP(A), $.10 8.13 8.27 8.36 8.47 NAMEPLATE PAAO 5 .1 o Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 Tsivi a-09x2 ® wNeHOEe Short Circuit Currenf Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency 9.(%) 14.7 15.0 : 15.3 '. 15.6 15.9 1THE TRINAM®UNT M®®ULE 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m2 according to EN 60904-1. E ,o o E 0 3 3 ... ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 '-'"..- 6.-a'CE11-:: ''''' '''''' '-' Maximum Power PMA.(Wp) 174 178 181 184 188 T {�pi;;;;,, `■, ' Maximum Power Voltage-V.,(V); 26.6 26,8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE 6e,,uroUNDIN„HOLf A MPP(A) A Maximum Power Current-I.,, 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOtNT FRAME DRAIN HOLE .': Short Circuit Current -s 7.04 7.10 7.25 7.31 7.37 �'� Open CircVit Voltage(V)-Voc(V)I 34.1 34.2 34.3 34.4 34.6 (A)Ic(A) r• - ' 812mm 180 NOCT:Irradiance at 800 W/m,Ambient Temperature 20 C,Win ped 1 m/s. Wind e ,. � Back View POWER OUTPUT RANGEMECHANICAL DATA Our most VerSltl a product _ Solar cells Multicrystalline 156*156 mm(6 inches) ® I .1 • Compatible with all major BOS components and system designs Cell orientation 60 dells(6 x 10)... : . . ' o Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) ., Weight 18.6.kg(41.01 lbs( -.. . I�.- M.�x'mum EFF�CIE I CY Glass High transparency solar glass 3.2 mm(0.13 inches) v 1.15 One of the industry's most trusted modules t Ano Anodized AluminiumTrina mount White .' ids- Frame Black d'ed Alloy with T' mount Groove r'.,!,®: Over 2 GW sold across all major global markets .. - IP rated r1 • Field proven performance 1-V CURVES OF PV MODULE TSM-245 PA05.18 J Box IP or 67 i:' Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 1:.. 0 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 6.: BConnector OriginalMC4 i .-`. _ySOOW/m' Q Highly reliable due to stringent quality control 5' \m As a leading global manufacturer ® • Over 30 in-house tests (UV,TC,HF,and many more) c 4.W \gym TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements we believe close 2o0w/m2 `AIM Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products, ; ....._.-_.-_._.._..... __..___._...__.__....�_..._0 . "1� Temperature(NOCT) cooperation with our partners `11 Maximum System 1000V DC(IEC)/ is critical to success. With local 0.o.°' 10.. 20.. 30.°° W Temperature Coefficient of PMAx -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina is - Voltage)VI Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of[so 0.047%/°C to each customer in each market and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing S.%) conditions of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually beneficial collaboration with 25 year Linear Power warranty (Please refer to product warranty for details) - installers,developers,distributors o and other partners as the �I • backbone of our shared success in CERTIFICATION 15 LINEAR PERFORMANCE WARRANTY ' driving Smart Energy Together. ( �� SA PACKAGING CONFIGURATION • 10 Year Product Warranty•25 Year Linear Power Warranty \% cm ,,„„ c�us Modules per box:24 pieces Trina Solar Limited www.trinasolar,com as ....=a: Modules per 40'container:672 pieces - X100% ISQ %I C E own PV CYCLE Additfongl valu Luno �! p 90% to tlahl Tlrna Safq•s t rnear Warranty • CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. cAMPA>ig T• C ctr o c circ ©2013 Trina Solar Limited.All rights reserved.Specifications included in this daiasheet are subject to e y rinasola O 80% r Tir nnnnnnnnnasol ll change without notice j�� Smart Energy Together Years s o s 20 25 Smart Energy Together °nntPro� :ustr sr „aro II Trina Solar Additional highlights: Solar inverters — RS-485 communication interface r (for connection to laptop or data logger). - a r. ' _' %�� . ����> � _ � � iI ? — Integrated ,w Arc Fault Detection and ( Interruption(-A Version). f mo id C fir` Technical data and types Type code PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US T. . ipa AU Mechant api ciffcetions . ., . ,' Nominal output power 3000W 3600W 3W0 3800W 4200W 3000 3300' 3300' 3600 4000' 4000' 3300 4200' 4200' 4200 4600' 4600' Maximum output power wattage r'.. W W W W W..._... W .........W W W.... W W W =F:= Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V ...y - Ino Tis. .1-` . .. r - ,., '; € a toric '.:. .�.. . . ... ': 's , . Number of independent MPPT channels 2 2 2 2 urro Maximum usable power for each channel 2000W 3000W 3000W 3000W Absolute maximum volta e(Vmax) 600V Start-up voltage(Vstart) 200V(adj.120 350V)„- Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V ® Operating MPPT voila e range 0.7 x Vstart 580V(>=90V) ° Maximum current(Idcmax)for both MPPT in 20A 32A 32A 32A parallel.... g., - Maximum usable current per channel 10A 16A 16A 16A Maximum short circuit current limit per 12.5A 20.0A 20 OA 20 0A channel Number of wire landing terminals per channel 2 pairs . yrma.mc Array wiring termination Terminal block,pressure clamp AWG10 AWG4 . OUtpot side.(AG)' ' Grid connection type 10/ Split- 10/ 10/ Split- 16/ 10/ Split- 10/ 16/ Split- 10/ 2W 0/3W 2W 2W 0/3W 2W . 2W . 0/3W 2W 2W 0/3W2W.,,,,. , �„�� � ,., Adjustable voltage range(Vmin-Vmax)(V) 183- 211 - 244- 183- 211- 244- 183-28211- 244- 183- 211- 244- __- 228V 264V 304V 228V 264V 304V 228V 264V 304V 228V 264V 304V Grid frequency... 60Hz Adjustable grid frequency range 57 60.5Hz . ..... Maximum current(lac,,*) 14.5 14.5 12.0 17.2 16.0 16.0 16.0 16.0 16.0 20.0 20.0 20.0 ARMS.........ARMS ......ARMS..... ..ARMS........ARMS...... ARMS........ARMS..,......ARMS........ARMS.. ARMS.......ARMS.........ARMS..... Power factor >0.995 Total harmonic distortion at rated power <2% i This family of single-phase string The high-speed MPPT offers real- Highlights: Grid wiring termination type Terminal block,Pressure clamp,AWG10 AWG4 inverters complements the typical time power tracking and improved — Single phase and split phase output Input protection devices Reverse polarity protection Yes number of rooftop solar panels energyharvestin9• grid connection. Over-voltage protection type Varistor,2 for each channel enabling home-owners to get the most The flat efficiency curve ensures high — Wide input range for increased PV array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) , efficient energy harvesting for the size efficiency at all output levels allowing stringing flexibility. Output protection devices: of the property. a consistent and stable performance — The high speed and precise MPPT Anti-islanage protection Meets UL 1741/IE(L -L,/47 requirements . Over-voltage protection type Varistor,2(L,-L/I G) across the entire input voltage and algorithm offers real time power Maximum AC OCPD Rating 20AR0,, 20AR,,,,G 15AR,,, 25A0,,„ 20AR„,,, 20A0,,,, 20ARM, 20ARM, 20ARM,.25A0,,° 25ARM, 25ARM,, This inverter offers a dual input output power range. tracking and improved energy Efficiency . section that processes two strings The transformerless operationgives the harvesting. Maximum efficiency96 9/ 97% 97% 97% 9 P GEC efficiency... _.. ... _.... ... 96% ... with independent Multiple Power Point highest efficiency of up to 97.0%. — Outdoor NEMA 4X rated enclosure Operating performarica. Tracking(MPPT). The wide input voltage range makes for unrestricted use under any Night time consumption <0.6WRti,, This is especially useful for rooftop the inverter suitable to low power environmental conditions. Standby consumption <8WR,, Comrrsunicatioa installations with two different installations with reduced string size. — Integrated DC disconnect switch User-interface 16 characters x 2 lines LCD display Remote monitoring(1xRS485 incl) VSN700 Data orientations from two sub arrays This rugged outdoor inverter has been in compliance with international Logger(opt.) oriented in different directions. (For designed to be a completely sealed Standards(-S Version). Envnmentai Ambient air operating temperature range 13°F to+140°F with derating above 122°F(50°C) example: East and West) unit able to withstand the harshest Ambient air storage temperature range 40°F to+176°F(-40°C to+80°C) The dual input sections with environmental conditions. Relative humidity 0-100%RH condensing independent MPPT enable a more Acoustic noise emission level <50 db(A)@1m P operating altitutde without derating 6560 ft(2000 m) „ ,D ,I e ... r... optimal energy harvesting condition. Power and productivity 1 Maximum enabled at nominal AC voltage and with sufficient DC power available. for a better world' �41,,.le 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD i