Plans (29) PITCH: 30 ARRAY PITCH:30 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Comp Shingle STORY: 2 Stories 8695 SW Stratford Ct (E)DRIVEWAY Front Of House ,FID-; C) EI AC LL_J AC HH ® LEGEND 0 Unoockeo Gated Q (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS oc DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS 0 DC JUNCTION/COMBINER BOX & LABELS di-Luded bAK • 0 DISTRIBUTION PANEL & LABELS o o o c o o Lc LOAD CENTER & WARNING LABELS o C 0 0 0 o O M DEDICATED PV SYSTEM METER O 0 0 c Q` /° W 0 STANDOFF LOCATIONS ) 0 0 0 0 0 W CONDUIT RUN ON EXTERIOR 0 0 0 o CONDUIT RUN ON INTERIOR GATE/FENCE o o o 0 0 0 0 HEAT PRODUCING VENTS ARE RED . c..---i • o 0 o o o ' `I INTERIOR EQUIPMENT IS DASHED I L=, QSITE PLAN N TOTAL ARRAY AREA (SF): 503 1'= TOTAL ROOF AREA (SF): 2075 Scale: 3/32" w m E TOTAL ARRAY AREA IS a 24.26 01' 10' 21' PERCENT OF TOTAL ROOF AREA _ S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBERPREINSE OWNER: DESCRIPTION: DESIGN: JB-9722171 00 cu, CONTAINED SHALL NOT BE USED FOR THE JOACHIMS, JULIE JOACHIMS RESIDENCE Jim McLean -= SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM .,,li NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8695 SW STRATFORD CT 7.14 KW PV ARRAY ��� PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Cleavkw Way THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: REV DATE say Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN MVER7ER T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. (503) 888-5889 ABB # PVI-6000—OUTD—US—Z—A SITE PLAN PV 2 10/14/2014 (888)-SOL-CITY(765-2489)www.sobcitycom . \\ ,/ (E) 2x12 .11,p .-- • / b\__ (E) LBW 00,,,,,,,,,,„„,0„,„„ 11'-3" 9'-6" / 1'-+ (E) LBW + A SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES PV MODULE LANDSCAPE 72" 24" STAGGERED STRUCTURE MEETS THE 5/16" BOLT WITH LOCK INSTALLATION ORDER PORTRAIT 48" 18" PRESCRIPTIVE REQUIREMENTS & FENDER WASHERS ROOF AZI 180 PITCH 30 OF THE OSISC SECTION 305.4 LOCATE RAFTER, MARK HOLE RAFTER 2x10 @ 24" OC ARRAY AZI 180 PITCH 30 STORIES: 2 ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT C.J. 2x12 @24"OC Comp ShingleHOLE. ZEP ARRAY SKIRT (6) (4) c SEAL PILOT HOLE WITH POLYURETHANE SEALANT. ZEP COMP MOUNT Ci. ,A 1M1 ['•;,11 ZEP FLASHING C �Trlillt 111111r� (3) INSERT FLASHING. rZ�jL— ��jY- (E) COMP. SHINGLE v�;�� .. .. 11._ (4) PLACE MOUNT. • (E) ROOF DECKING IJI INSTALL LAG BOLT WITH 5/16" DIA STAINLESS (5) (5) SEALING WASHER. STEEL LAG BOLT LOWEST MODULE SUBSEQUENT MODULES ---(6') INSTALL LEVELING FOOT WITH WITH SEALING WASHER BOLT & WASHERS. (2-1/2" EMBED, MIN) (E) RAFTER0 STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HERONJ B-9722171 00 PREMISE OWNER. DESCRIPTION: DESIGN: JOB NUMBER: ���_ ■ CONTAINED SHALL NOT BE USED FOR THE JOACHIMS, JULIE JOACHIMS RESIDENCE Jim McLean ��;SO�afC�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM ;'"° NOR SHALL IT BE DISCLOSED IN WHOLE OR IN CompMount Type C 8695 SW STRATFORD CT 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODIILE �' TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WI1H 3055 aearview Way THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: % DATE: son Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1026 F:(s50)236-1029 PERMISSION OF SOLARCIIY INC. ABB # PVT-6000—OUTD-US-Z-A (503) 888-5889 STRUCTURAL VIEWS PV 3 10/14/2014 (666)—sa—aTY(ass-2489)www.ealaraity.aam UPLIFT CALCULATIONS 10.09.2014 � e y SolarCitv SleekMountT"' RV System Version#39.5 Structural Design Software Project Information&Table Of Contents Risk Category: II PV System Type SolarCity SleekMount'"" Comp Roof Comp Roof Layers of Comp Roofing 1 Roof Slope 30° Rafter Spacing 24"Q.C. PV System Module Orientation Landscape and Portrait PV Module Area 546 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf 'ASCE Table 7-1 Surrounding Roof Snow 100% 25.0 psf 'ASCE Eq:7,4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Endosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C ' Section 6.5.63 Roof Style Gable Roof 'Fig.6-118/C/D-14NB Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(VA2)(I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.95 Fig.6-11B/C/D-14NB Ext Pressure Coefficient(Down) GCp(Down) 0.88 Fig.6-1UBIG0-14Ne Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure Up p(up) -17.7 psf Wind Pressure Down p(down) 16.3 psf Allowable Standoff Spacings X-Direction V-Direction Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual -314 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capadty DCR 62.8% Max Allowable Standoff Sparing Portrait 48" 65" Max Allowable Cantilever Portrait 18" NA Standoff Configuration Portrait Staggered Max Standoff Tributary Area Trib 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff 1-actual -348 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Demand/Capacity DCI 69.7% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9722171 0 0 PREMISE OM: DESCRIPTION: DESIGN: \�, • CONTAINED SHALL NOT BE USED FOR THE JOACHIMS, JULIE JOACHIMS RESIDENCE Jim McLean '; Solani+ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ;ij° NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8695 SW STRATFORD CT 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENTS MODULESTIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clean/Jew Way THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-255PA05.18 PACE NNS: SHEEL REN DALE: Son Mateo,CA 94402 PERMISSION OFPMENT,SOLARCITY INC..T THE WRITTEN ,N„�,�: (503) 888-5889 PV 4 10 14 2014 (888)-soL-a (765-2489)18 F:(650) :6 w),wealar0tycam ABB # PVI-6000—OUTD—US—Z--A UPLIFT CALCULATIONS / / GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD Panel Number:Westinghouse Inv 1: DC Ungrounded INV 1 -(1)ABB # PVI-6000-OUTD-US-Z-A LABEL A -(28)TRINA SOLAR # TSM-255PA05.18 OR # 180498 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24 578 428 Tie-In: Supply Side Connection FCI Inverter; Zigbee 6000W, 240V, 96.5% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Underground Service Entrance INV 2 Voc: 37.7 Vpmax: 30.5 - INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER • E 100A MAIN SERVICE PANEL E 100A/2P MAIN CIRCUIT BREAKER Inverter 1 IND (E) WIRING CUTLER-HAMMER Disconnect COOPER CUTLER-HAMMER ® Meter Socket Disconnect n ABB 9 DC+ Vstart= DEFAULT! A 35A PVI-6000-OUTD-US-Z-A Dc- / MP 1: 1x14 4 -I n ��� B C EGC / , • A A �o r /i■--� _ A L, Tj J 100A/2P B l-1 I ■'-■ I ' . L2 .- DC- ' 4 tEl V J N =Le� DC- I Z Vstart= DEFAULT E LOADS GND _ _ _ __ ___ GND _ EGC/ _-- e� DC+ DC+ I, LD ( )� - ilk..... ../-4D 1-r- GND - fi r' GEC -11[!3 �_ DC- DC- MP 1: 1x14 F"-' -_J �/ I GND I____Eg--_ ----f EGC / I (1)Conduit Kit; r EMT N I J o I Z-( - T GEC4 TO 120/240V ' SINGLE PHASE � UTILITY SERVICE I Voc* = MAX VOC AT MIN TEMP POI-(2)ILSco!IPC 4/0- A 1- CUTLER-HAMMER I DG222NRB /fj C DC Insulation Piercng Connector; Main 4/0-4, Tap 6-14 Disconnect; 6OA, 24OVac, Fusible,NEMA 3R 4 C -(1)CUTLER-HAMMER i DG100NB -(1)CUTLER-HAMMER#DG222URB Ground/Neutral ,t; 60-100A General Duty(DG) Disconnect; 60A, 24OVoc, Non-Fusible, NEMA 3R -(1)CUTLER-HAMMER/DS16FK -(1)CUTLER- AMMERDG100NB Class R Fuse Kit Ground/Neutral Kit; 60-100A, General Duty(DG) -(2)FERRAZ SHAWMUT/1R35R PV BACKFEED OCP SSC}-SUPPLY SIDE CONNECTION. DISCONNECTING MEANS SHALL BE SUITABLE Ful 35A, 250V,Class RK5 AS SERVICE EQUIPMENT AND SHALL BE RATED PER NEC. 1---T1 (1)COOPER/B-Lne Meter Socket 011 Meter Socket; 125A, 4-14AWG,Ring Type -(1)AW CAP; B-Line Meter Socket Accessory -(1)Milbank its Single nkra 'CL2 /Won C1S ; _ - (1)AWG 16,THWN-2,Black (2)AWG/10, PV YNRE Black Voc =591.98 VDC Isc =8.92 ADC cn (1)AWG 16,THWN-2,Red O[if(1)AWG 16, Stranded Bare Copper EGC Vmp =427 VDC Imp=8.36 ADC ® -(1)AWG 18, THWN-2,Black (1)AWG/6, THIN-2, White NEUTRAL Vmp =240 VAC Imp=28 MC (1)Conduit Kit; 3/4' EMT 7.0)AWG/6,.Solid Bare,Caper. GEC. . . (1)Conduit,Kit;.3/4'.EMT, ,,, . , . . . . O -Q-(1)AWG 18, THWN-2,Red (2 AWG 110, PV WIRE, Block Voc* =591.98 VDC Isc =8.92 ADC ,-- AWG (1) #10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=28 MC I 0 QE(1)AWG#6, Stranded Bare Copper EGC Vmp =427 VDC Imp=8.36 ADC N . , .. . . .-(1)AWG IA.TH.WN-2,.Green , . EGC/GEC, nd (1)Couit,Kit;,3/4`.EMT.. . , , , , , , , (1)Conduit Kit; 3/4'EMT J B-9722171 00 PREMISE OYMER: DESCRIPTION: DESIGN: CONFIDENTIAL- NE INFORMATION USED FORHEREIN JOB NUMBER: ��j,,SolarCity CONTAINED SHALL NOT BE USED NE JOACHIMS, JULIE JOACHIMS RESIDENCE Jim McLean -. ; BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: �'`" NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8695 SW STRATFORD CT 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE NE RECIPIENTS s TIGARD, OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 aeaview Way NE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: REV DATE San Mateo,CA 94402 PERMISSION TTY EQUIPMENT, IMTHouT THE WRITTEN INVErtTER THREE LINE DIAGRAM T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARClTY INC ABB # PVI-6000-OUTD-US-Z-A (503) 888-5889 PV 5 10 14 2014 (888)-SOL-aTY(765-2489)www.sdacity.com ELECTRICAL CALCULATIONSModule: 28 TRINA SOLAR#TSM255 ZEP 232.2 Inv Power WPIC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 ABB PVI 6000 S AFCI 0.965 6000 6274.04 Vdrop= (Imp) " (2*Length)"(Resistance) / (Vmp) Module: I Imp(A) Max.Length(ft) Wire Inverter 2: String: 8.36 120 AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 *240 *0.00124Dhms) / 351.7199 0.71 Inverter 3: Branch: 8.36 I 85 I AWG_10 at Max Ave Hi:87 deg F Module: Vdrop= (8.36 * 170 *0.00124Dhms) / 351.7199 0.5 Inverter 4: Total voltage drop in DC conductors= 1.21 Inverter: 8.36 f 25 I AWG_8 at 240V Vdrop= (8.36 *50 *0.00078Ohms) / 240 V 0.13585 Total: 28 Modules Total Inv Pwr: 6000 6274.04 PTC Combined: 0 I 0 I AWG_8 at 240V Photovoltaic Module Electrical Specifications: Total STC: 7140 Vdrop= (0 *0 0.00078 Ohms) / 240 V 0 Voc: 37.7 V deg F deg C Vmp: 30.5 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.14 Isc: 8.92 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.34 Imp: 8.36 A Record Hi Temp: 96 36 Tvoc: -0.12064 V/deg C Tisc: 4.1924 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 85 Voc Correction Factor: ABB PVI-6000-S AFCI 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 14 TRINA SOLAR#TSM-255 ZEP 14 modules per series string 14 modules per series string Voc= 527.8 Min Vmp at Max Temp: 351.72 Voc= 527.8 V Voc= 527.8 V Max Voc at Min Temp: 591.98 Vmp= 427 Inverter Max Vdc Input: 600 Vmp= 427 V Vmp= 427 V Isc= 8.92 Isc= 8.92 A Isc= 8.92 A Imp= 8.36 Max String Size: 14 Imp= 8.36 A Imp= 8.36 A lcont= 11.15 Art 690.8(A)(1) 1-way wire length: 120 lcont= 11.15 A lcont= 11.15 A Art 690.8(A)(1) 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 1 Conductor 2: AWG_10 (cont*1.25=(Amps) 13.94 Conductor 1 Conductor 2 30 deg C ampacity= 40 Icont*1.25=(Amps) 13.94 13.94 1.b Icont=(Amps) 11.15 30 deg C ampacity= 40 40 Start ampacity 40 2.b lcont=(Amps) 11.15 11.15 Temperature derate(%=F) 0.76 Start ampacity 40 40 Conduit fill derate(%_#) 1 Temperature derate(%=F) 0.76 0.76 Derated ampacity 30.4 Conduit fill derate(%=#) 0.8 0.8 1.c Derated ampacity 24.32 24.32 (cont*1.25=(Amps) 13.94 2.c Term 1 Term 2 Ampacity 40 Temp table 75degC 75degC Icont*1.25=(Amps) 13.94 13.94 1.d Icont*1.25=(Amps) 13.94 Ampacity 35 35 OCP Size= 15 Inverter Type A Output 2.d OCP Size= 15 15 ABB PVI-6000-S AFCI 1 way wire length: 10 ft Combined Inverter Output Icont= 28 A Art 690.8(A)(1) Service Voltage= 3.a Icont*1.25=(Amps) 35 Art 690.8(B)(1) Total Inverter Power= 1 way wire length= 0 OCP Size= 35 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor: AWG_8 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) Icont*1.25=(Amps) 35 4.a Icont*1.25=(Amps) 35 Art 690.8(B)(1) 30 deg C ampacity= 55 OCP size= 35 Art 240.6(A) 3.c Icont=(Amps) 28 4.b Conductor: AWG_8 THWN-2 at 90 deg C:Table 310.16 Start ampacity 55 Icont*1.25=(Amps) 35 Temperature derate(%=F) 0.91 30 deg C ampacity= 55 Conduit fill derate(%=#) 1 4.c Icont=(Amps) 28 Derated ampacity 50.05 Start ampacity o - 55 3.d Icont*1.25=(Amps) 35 Temperature derate(/o=F) 0.91 Ampacity 50 Conduit fill derate(%=#) 1 Derated ampacity 50.05 4.d Icont*1.25=(Amps) 35 Ampacity 50 J B-9 7221 71 0 0 PRE}SE OWNER DESCRIPTION: DESIGN: CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: '**I‘1, CONTAINED SHALL NOT BE USED FOR THE JOACHIMS, JULIE JOACHIMS RESIDENCE Jim McLeanSO�a�C�ty BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: •r8 NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 8695 SW STRATFORD CT 7.14 KW PV ARRAY PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: TIGARD OR 97224 ORGANIZATION, EXCEPT IN CONNECTION WITH r 3055 Cleaview Way THE SALE AND USE OF THE RESPECTIVE (28) TRINA SOLAR # TSM-255PA05.18 PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WI1HOUT THE WRITTEN INVERTER T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. ABB # PVl-9000-OUTO-uS-z-A (503) 888-5889 ELECTRICAL CALCULATIONS : PV 6 10/14/2014 (888)-SOL-CITY(765-2489)www.ealarcIty.aom Label Location: Label Location: Label Location: • CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC)(P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: - IFC 605.11.1.4 MAXIMUM AC - v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC)(INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POWER- (DC) (DC)(INV) UNGROUNDED AND INVERTER IS POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER _v NEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUITA Per Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC)(CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.6.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5 C WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED ( ) HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC _ A AC (P01) OPERATING CURRENT (AC): AC Disconnect PHOTOVOLTAIC AC (AC) MAXIMUM AC _ (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE V (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (POI) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 014 ` ir 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �= ■ San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - OR Label Set �������So�arC1 T:(650)638-1028 8:(650)638-1029 EXCEPT IN CONNECTION VNTH THE SALE AND USE OF THE RESPECTIVE If (sss)-Soi-cm(765-24s9)www.saarcity.can SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ZS Comp Edge Zone Calculations 1 of 4 0 ZS Comp Edge Zone Calculations 2 of 4 . Z ep S a h r 5/28/13 Ze p 5/28/13 Solar This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing - spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load down force spacing= calculations will vary the design variables to account for the worst case for each failure mode that is being module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads _ design load landscape- 9.62 17.32 17.32 psf Uplift= 656 lbs design load portrait= 7.70 17.32 17.32 psf Lateral= 436 lbs Down Force= 1147 lbs . ,A!�- -Ro note:use 10 psf minimum r : ;�� Snow Calculations Attachment Spacing Calculations 1 85818 12 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing „ OREGON o � lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes ✓ m �� � above 30 degrees. Allowable Uplift Load uplift spacing= �RMY Roo�� module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch 14 30 ASCE 7-05 Method 2 Design Snow Load 29.11 25.98 psf p=ghGCN (snow load spread over the length of the rafter) qh=0.00256 KZ K,Kd V2 I Basic Wind Speed= 95 mph Down Force Load Roof Pitch Exposure= C Roof Zone= Edge Zone Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof Kn= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf forst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 Iscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape down force spacing= 39"x132.46psf x 144 in = 130" ortrait effective area= 21.7 ft2 Plandscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = ft2 65"x 32.46psf x 144 =78" a Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) - design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = 39"x 29.05 psf x 144 ft2 =83" 656 lbs /in portrait uplift spacing = 65"x 27.12 psf x 144 ft2 = 54" ZS Comp Edge Zone Calculations 3 of 4 ZS Comp Edge Zone Calculations 4 of 4 5/28/13 5/28/13 ZepSotar ZepSolar Lateral Spacing Module Deflection Spacing landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing= -1.4545 x 32.46 psf+120.7273 =73" PS=C5 Pf Roof Pitch= 31 45 degrees pf=0.7 Ce cop,pg Ce= 0.9 CS= 0.71 0.45 portrait module spacing=-1.7917 x 32.46 psf+118.58=60" Cf= 1.2 pf= 22.68 22.7 psf I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check p Landsca a Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) Lateral 30° 27° 30° 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.75S 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing= 39"x 14.49 psf x 144 ft2 =74" 292lbs in portrait lateral spacing= x 144 65"x 14.49 psf ft2 =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" i SolarCity SleekMountTM - Comp SolarCity SleekMountTM Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed ;, Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules \ • aesthetics while minimizing roof disruption and 40.Interlock and grounding devices in system UL Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends andFastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps,combined with the addition Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 to a more visually appealing system.SleekMount as"Grounding and Bonding System" 40 Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as ".„ layer of shingle strengthened frames that attach directly to grounding device • Place Comp Mount centered Zep Solar standoffs, effectively eliminating the • need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance 40 Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw Place module 4, riff a Components Sly.- • _ • 5/16"Machine Screw• �' 4- Leveling Foot I n.;,. I 40 Lag Screw ,,,,,,,,,„;„, k . H.„ 8 Comp Mount : • Comp Mount Flashing M ‘clii.. ir:al' �• Soiarity® January 2013 tee•/ LISTED + SolarCity, January 2013 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-Pen,(Wp) 240 245 250 255 260 Power Output Tolerance-Pen,(%) 0/+3 0/+3 0/+3 0/+3 0/+3 ,uNr„oN I o Maximum Power Voltage-Ver.(V) 29.7 30.2 30.3 30.5 30.7 Pox Maximum PowerCurrenT-IMPP(A) 8.10 8.13 8.27 8.36 8.47 NAMEPLATEAn ISM PA05 .1Open Circuit Voltage-Vac(V) 37.3 37.5 37.6 37.7 37.9 59x1] wsTAuiNc HOLE Short Circuit Current-Inc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency qm(%) 14.7 15.0 15.3 15.6 15.9 3 THE TRINAMOUNT MODULESTC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction of 4.59°at 200 W/m'according to EN 60904-1. E no E � 3' 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Pen,(Wp) 174 178 181 184 188 .� A A Maximum Power Voltage-VMP(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE 604]GROUNDING HOLE Maximum Power Current-IMPP(A) 6.55 6.64 6.70 6.77 6.86 / o-r,elN Nori Open Circuit Voltage(V)-Vac(V) 34.1 34.2 34.3 34.4 34.6 WITH TRINAMOUNT FRAME %f 66!! Short Circuit Current(A)-kc(A) 7.04 7.10 7.25 7.31 7.37 I 812mm I O 180 I NOCT:Irradiance at 800 W/m°,Ambient Temperature 20°C,Wind Speed 1 m/s. 240-260W Baak View MECHANICAL DATA POWER OUTPUT RANGE Our most versitile product - Solar cells Multicrystalline 156 x 156 mm(6 inches) • Compatible with all major BOS components and system designs Cell orientation 60 cells(6 x 10) Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05 x 1.57 inches) 15.90 Weight 18.6 kg(41.0Ibs) MAXIMUM EFFICIENCY L Glass High transparency solar glass 3.2mm(0.13inches) Backsheet White //--� One of the industry's most trusted modules Frame Black Anodized Aluminium Alloy with Trinamount Groove ►`,�;:: • Over 2 GW sold across all major global markets 0.%•+3% • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box Cables P 65 or IP 67 rated Photovoltaic Technology cable 4.0 mm'(0.006 inches'), M.. 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9 --14)win,' -"- Connector Original MC4 8. W 7. 800W/m' < Highly reliable due to stringent quality control 6. 6t10W/m` N 540 As a leading global manufacturer n • Over 30 in-house tests(UV,TC,HF,and many more) 4m 4a0W/m' - TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements a 2 20oW/m \ Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close Temperature(NOCT) 1 - Maximum System 1000V DC(EC)/ cooperation with our partners 0.° Temperature Coefficient of PMA, -0.43%/°C Voltage 600V DC(UL) is critical to success. With local a. 10.00 20.. 30.p0 40.p0 presence around the globe,Trina is voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Isc 0.047%/°C to each customer in each market Certified to withstand challenging environmental and supplement our innovative, -v reliable products with the backing =- J conditions 6 of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Product Workmanship Warranty to building strategic,mutually 25 year Linear Power Warranty beneficial collaboration with > (Please refer to produc}warranty for detailsi installers,developers,distributors o and other partners as the backbone of our shared success in CERTIFICATION n driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY -4 PACKAGING CONFIGURATION ,�- 0" o��❑s Modules per box:24 pieces 10 Year Product Warranty•25 Year Linear Power Warranty A.� �* Trina Solar Limited y I 1111 .4"�., Modules per 40'container:672 pieces F ISO is 6T-Jus PV-tYCLE www.trinasolar.com a,too9 9,� �E' rraT�o V o Additional 2. value fro rino ,3): 90% ,A G T So qr�g linear M'arrant• CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. �poMPATjB y • 82013 Trina Solar Limited.All rights reserved.Specifications included in this data)st are subject to 4 / 4n Tnnasolar BO% Tnnasolar change without notice Smart Energy Together •`acoO. Smart Energy Together Years s t0 t5 20 25 ts Additional highlights: • — RS-485 communication interface (for connection to laptop or data • logger). - — Integrated Arc Fault Detection and Interruption(-A Version). In t: 1 Technical data and types PVI-5000-OUTD-US PVI-6000-OUTD-US __ Input side ,-- t ..°. Nominal output power 5000W 6000W I &i Maximum output power 5000W 6000W • ,;___. ,, Rated grid AC voltage 208V 240V 277V 208V 240V 277V _ Input side(DC) A Number of independent MPPT channels 2 Maximum usable power for each channel 4000W Absolute maximum voltage(Vmax) 600V Start-up voltage(Vstart) 200V(adj.120-350) °_-.. Full power MPPT voltage range 200 530V Operating MPPT voltage range 0.7 x Vstart-580V Maximum current(Idcmax)for both MPPT in parallel 36A Maximum usable current per channel 22A 4 w•^^°' A. Number of wire landing terminals per channel 2 Pairs • <;, Array wiring termination Terminal block,pressure clamp,AWG16-AWG6 Output side(AC) ,,,, Grid connection type 10/2W Split 0/3W 10/2W 10/2W Split 0/3W 10/2W Adjustable voltage range(Vmin-Vmax) 183V 228V 221V-264V 244V-304V 183V 228V 211V-264V 244V-304V Grid frequency _ 60Hz a Adjustable grid frequency range 57-60.5Hz Maximum current(L )A us.._.. .... 27Aams 23AFes... 20A„,„. 30A„,„,s 28Awns 24Awas ... The wide input voltage range Highlights: Power tactor >0.995 Designed for residential and small Total harmonic distortion at rated power <2% makes the inverter suitable to low Singlephase and split phase output 36.25 A°k/ 36.5 A°k/ 31.75 A°k/ 36.25 A k/ 36.5 A / 31.75 A / commercial PV installations,this - 9 p Contributory fault current 25.63A 25.81 22,45A 25.63 25.81 °k 22,45Aq p power installations with reduced ALs inverter fills a specific niche in the grid connection. Grid wiring termination type RM5 Terminal block,pressure clamp,AWG14-AWG4� Ms ABB product line to cater for those string size. - Wide input range for increased Input The transformerless operation offers stringing flexibility. Reverse polarity protection Yes installations producing between g g Over voltage protection type Varistor,2 for each channel 5kW and 20kW. high performance efficiencies of up to _ The high speed and precise MPPT y 9i 1% PVOver-voltage array ground fault detection Pre start-up Riso and Dynamic GFDI(requires floating arrays) algorithm offers real time power Output Free remote monitoring capability trackingand improved energyAnti islanding protection Meets UL 1741/IEEE1547 requirements Meets UL 1741/IEEE1547 requirements This inverter includes dual input Over-voltage protection type Varistor,2(L,-L.z/L, G) Varistor,2(L,-La/L,-G) process two strings with section toavailable with every installation.This harvesting. g enables homeowners t0 view their Maximum AC OCPD Rating 35A 30A 25A 40A 35A 30A independent MPPT. Outdoor •NEMA 4X rated enclosure Efficiency The high speed and precise MPPT energy production and offers installers for unrestricted use under ai Maximum efficiency 97.1% M algorithm offers real-time power a proactive and economic way of environmental conditions. CEC efficiency 96% 96.5% 96.5% 96% 96.5% 96.5% maintainingand troubleshootingthe User interface Graphic display Graphic display tracking and energy harvesting. - Integrated DC disconnect switch Operating performance -csystem. Flat efficiency curves ensure high n compliance with international stand-by consumption <$//„ <8W,,,,, efficiency at all output levels ensuring Standards(-S Version). Night time consumption <0.6W,,„„ <0.6W,,,,° Communication consistent and stable performance User-interface 16 characters x 2 lines LCD display across the entire input voltage and Remote monitoring(1xRS485 incl.) VSN700 Data Logger(opt) p g PVI-USB-RS485_232(opt.) Wired local monitoring(1xRS485 incl.) output power range. +, Environmental This outdoor inverter has been -13°F air operating temperature range -13°F to+140°F(-25°C to+60°C) 13°F to+140°F(-25°C to+60°C)with designed as a completely sealed unit to derating above 122°F(50°C) Ambient air storage temperature range -40°F to+176°F(-40°C to+80°C) 40°F to+176°F(-40°C to+80°C) withstand the harshest environmental Relative humidity 0 100%RH condensing 0 100%RH condensing conditions. IL ,I ,II Acoustic noise emission level <50 db(A)@t m <50 db(A)@1 m Maximum operating altitutde without derating 6560 ft(2000 m) 6560 ft(2000 m) Power and productivity2.Inverter can apply that much current-Breaker will open for a better world'" milk•W•w 2 ABB Solar Inverters I Product flyer for PVI-5000/6000-TL-OUTD