Plans ...- PROJECT PROJECT NOTES: SYSTEM INFORMATION VICINITY MAP-SCALE: NTS MODULE NOTES: TABLE OF CONTENTS z 1. 6240W DC, 5000W AC SOLAR PHOTOVOLTAIC SYSTEM. 1. REC SOLAR: REC260PE(BLK) DIMENSIONS: — 2. (24) REC SOLAR: REC260PE(BLK) MODULES WITH (1) MAGNETIC TRUE 65.55"x 39.02"x 1.5" PAGE POWER ONE: PVI 5000 OUTD US-A(240V) INVERTER. ARRAY PITCH ORIENTATION ORIENTATIONz FROM EDGE # DESCRIPTION _ c 2. PORTRAIT: CLAMP 8.2"-16.4" 3. TWO STORY COMP SHINGLE ROOF AT 24° PITCH. 3. LANDSCAPE: CLAMP 0"-9.8" FROM EDGE 4. CONSTRUCTION FOREMAN TO CONFIRM FINAL CONDUIT AR-01 24° 164° 180° I -= PV-01 SITE PLAN RUN PLACEMENT WITH CUSTOMER. 5. APN#:2S103CC099 4 4 o' ` RACKING NOTES:1. SNAPNRACK SERIES 100 OR S100 UL LISTED; ° FLUSH MOUNT L-FOOT. SEE PEN D01. PV-02 ATTACHMENT DETAIL 6. CONTACT: RONALD(FRED) BARBEE, (503) 590-4449 2. RAFTER AND PENETRATION LOCATIONS TO BE 7. DESIGN CRITERIA: 7.1. SYSTEM WEIGHT: 3LBS/SQFT. � � ��� - DETERMINED IN THE FIELD PV-03 ELECTRICAL - r 'ti = 3. LAG SCREWS: 5/16"X " . NT S-1 STRUCTURAL DETAIL i SEP 15 2014 t. CATY0FrIGARD SITE PLAN -SCALE=1/16"=1' �+ �� �1 (E) DRIVEWAY li D1 - AR-01 -SCALE: 3/9L1lt31 iCrIti ,V SW WHISTLER'S LN li PL PI 4 Ph3' 9'-10" 13'-2" _ 15'-11" CITY 444 A tl' OP TIGA ...f 0 El 0 r (E) SERVICE ENTRANCE IIREvntwED FOR CODE CO A 4 4 (EXTERIOR WALL) = / 11-.--14 g............ � � .�Ap I t� �� 1 L . Z L A ,� 6 95% 97°o (E) RESIDENCE aID o w (N) MAIN PANEL �TCi I ' _ 6.. 4 4 to e A (INTERIOR WALL) 2'-8" • , P©; '� 601, 1'-6" (Permit#,fC T �- � - 20 4" A. A I (N) PV PRODUCTION MET lAddrrese 2 Q e o suite � .,. _..... am A4 AND AC DISCONNECT ....... (EXTERIOR WALL) #S e........•o.......,•6 ,m � 7 , ---: (E) SKYLIGHTS Dates741 ` 23' 4 . = ",,, (N) INVERTER WITH —` 3' INTEGRATED DC o a# DISCONNECT , . -- i-- . a1 -� . . OFFICE COPY (EXTERIOR WALL) FIRE SETBACKS (E)GATE 2 5 (3'TYP) ° 26'-4" / Li (N) CONDUIT RUN INDICATES TSRF VALUE AT MARKED LOCATION (N)ARRAY AR 01 _ .... INSTALLER TO VERIFY RAFTER SIZE, SPACING NOTE: D2-SIDE ELEVATION -SCALE: NTS 0 0_ AND UNSUPPORTED SPANS AND NOTIFY E.O.R OF ANY DISCREPANCIES BEFORE I Q [ PROCEEDING. (E) PROPERTY LINE -,- MIX 3.. � �. PPO 28' 0. ''''--- 4114,114.4444.44N44611:411..._„,,,,,,,, �� � U . 24° 1141% PL PL PL STRUCTURAL CROSS SECTION - SCALE NTS SUNRUN,INC. 3380 SE 20TH,PORTLAND,OR 97202 DESIGNER: REV:A sunrun OR CL#180464 PHONE 503-766-4332 R. MORGAN SUNRUN PROJECT NUMBER: BARBEE RESIDENCE FAX 503-205-0748 BARBEE 601 R-240BAR6 SITE PLAN PV-01 0 DRAFTER: VELAZQUEZ ( ) 12240 SW WHISTLERS LN, TIGARD, OR 97223 9/11/2014 (2) 5/16"-18 x 2-1/2" SS HCS (2) 5/16" SS SPLIT LOCK WASHER11 SNAPNRACK MODULE MID CLAMP RAIL SPLICE INSERT NOTES: ® • LAG BOLTS MUST EMBED IN ROOF SNAPNRACK MODULE END CLAMP STRUCTURAL MEMBERS/RAFTERS • TORQUE ALL 5/16" HARDWARE TO 10 FT-LBS SNAPNRACK CHANNEL NUT O _ (120 IN-LBS) TORQUE '� ������ %� RAIL SPLICE TOP • RAIL CAN MOUNT TO EITHER SIDE OF L-FOOT SNAPNRACK STANDARD RAIL , �// (UPSLOPE VS. DOWNSLOPE) /�<" �� 0 (2) 5/16" SS SPLIT • FOR UNEVEN ROOFS, USE 1" STANDOFF SHAFT I� �o LOCK WASHER • r SNAPNRACK RAIL 5/16"-18 x 1" SS HCS SPLICE ASSEMBLY SNAPNRACK FLASHED STEP 3: SECURE L-FOOT TO L-FOOT KIT STANDOFF BASE TO 5/16" SS SPLIT SECURE FLASHING AND LOCK WASHER 5/16"-18 x 3.5" SS HLS MOUNTING RAILS (MIN 2.5" EMBEDMENT TO STEP 2: SLIP FLASHING OVER SNAPNRACK L-FOOT RAFTERS) L-FOOT BASE 5/16"x 3/4" FLAT WASHER STEP 1: BOLT L-FOOT BASE TO SNAPNRACK CHANNEL NUT ROOF WITH LAG BOLT 5/16"-18 x 3/4" SS HCS SNAPNRACK STANDARD RAIL ' 5/16"-18 SS FLAT HEX NUT \-..'4111k 5/16" SS SPLIT LOCK WASHER SNAPNRACK L-FOOT BASE ,ti`l/, \` ROOF DECKING SEAL PENETRATION AND 01 \v/ UNDER BASE WITH - - RAINBUSTER (OR iiill EQUIVALENT) SEALANT � � (E) ROOF DECKING �\��� `�P�`ON 11111111141111111 COMPOSITION CEO�NS�P 1 00.0 FLASHING COMP`E (E) RAFTER SNAPNRACK RACKING SYSTEM SERIES 100: L-FOOT MOUNTING DETAIL SUNRUN,INC. 3380SE20TH,PORTLAND,OR97202 R. MORGAN SUNRUN PROJECT NUMBER: BARBEE RESIDENCE I ATTACHMENT REV:A sunrun OR CL#180464 PHONE 503788-4332 DESIGNER: FAX503-205-0748 BARBEE 601R-240BARB 12240 SW WHISTLERS LN, TIGARD, OR 97223 PV-02 9/11/2014 0 DRAFTER: VELAZQUEZ ) DETAIL LINE DIAGRAM: 120/240 VAC SINGLE PHASE SERVICE SYSTEM CHARACTERISTICS-INVERTER 1 METER#: SYSTEM SIZE 6240 W < 43) PGE 24 155 061 SYSTEM OPEN CIRCUIT VOLTAGE 494 V UTILITY SYSTEM OPERATING VOLTAGE 368.4 V - GRID EXISTING MAX ALLOWABLE DC VOLTAGE 600 V 200A MAIN SYSTEM OPERATING CURRENT 17 A \q BREAKER SYSTEM SHORT CIRCUIT CURRENT 22.53 A LABEL PLACEMENT:AC BREAKER EXISTING PV MODULES (INSIDE OR FRONT OF PANEL) l` ~ 200A MAIN LOCKABLE POWER-ONE: PANEL BLADE TYPE DEDICATED PV PVI-5000-OUTD-US-A(240V) FACILITY REC SOLAR: REC260PE(BLK) AC DISCONNECT KWH METER 5000 WATT INVERTER JUNCTION BOX — +4 ,/ (12) MODULES LOADS ,----N3 3 3 1or-2 OR EQUIVALENT f---1 (1)STRING OF(12) MODULES 4174) o--e�o C }j alb OF j____ o��o –� PV MODULES FACILITY — — 2 1 / REC SOLAR: REC260PE(BLK) 30A PV GROUND SQUARE D 250V METER SOCKET DUAL MPPT TRACKERS STRING — +4j/! (12) MODULES BREAKER AT DU221RB 125A CONTINUOUS COMBINER& LOAD RATED DC ``II'' (1)STRING OF(12) MODULES OPPOSITE END 3R, 30A DISCONNECT AND AFCI OF BUSBAR 120/240VAC NOTES TO INSTALLER: CONDUIT SCHEDULE SIGNAGE: WARNING 1. 454 VDC EXPECTED OPEN CIRCUIT STRING VOLTAGE. 2. IN MAIN PANEL REPLACE (2)20A 1P BREAKERS WITH NEW 20/30/20AWARNING-Dual Power Sources ELECTRIC SHOCK HAZARD 1-2-1P QUAD BREAKER. CONNECT PV SYSTEM TO 30A 2P PORTION OF # CONDUIT CONDUCTOR NEUTRAL GROUND Second source is photovoltaic system DO NOT TOUCH TERMINALS LABEL PLACEMENT:MAIN PANEL! TERMINALS ON BOTH LINE AND NEW QUAD. 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER NEAR METER LOAD SIDES MAY BE ENERGIZED 3. PGE-FIT METER BASES SHOULD BE WIRED AS FOLLOWS: ULILITY ' WARNING IN THE OPEN POSITION SOURCE TO TOP LUGS, PV SOURCE TO BOTTOM LUGS. 2 3/4"EMT OR EQUIV. (2) 10 AWG PV WIRE NONE (1)6 AWG THHN/THWN-2 RELOCATE TH.OVERCURRE„,FENCE DC VOLTAGE IS ALWAYS PRESENT 3 3/4"EMT OR EQUIV. (2) 10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 LABEL PLACEMENT:BOX,I AC ERCONNECT, WHEN SEDT SUNLIGHT COMBINER BOX,INVERTER ARE EXPOSED TO SUNLIGHT WARNING-Electric Shock Hazer LABEL PLACEMENT: Voltage Drop AC VoltageDrop �� No user serviceable parts inside DC DISCONNECTS DC Conte«authorizetl eervicer ter assistance ELECTRICAL NOTES: LABEL PLACEMENT: sox INVERTER ADICONNECT, WARNING 1. PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2011 NEC. Run Name Inverter to Main Panel Run Name Modules to Inverter 2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2011 NEC. Select Material Cu Select Material CU CAUTION:SOLAR ELECTRIC ELECTRIC SHOCK HAZARD 3. PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY SYSTEM CONNECTED IFAGROUND FAULT IS INDICATED LABEL PLACEMENT: NORMALLY GROUNDED CONDUCTORS GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. Select Wire Size 10 Select Wire Size 10 CONDUIT,JUNCTION BOXES MAY BE UNGROUNDED AND ENERGIZED 4. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. PHOTOVOLTAIC POWER LABEL PLACEMENT: 5. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. Select Conduit Type EMT Select Conduit Type EMT SOURCE INVERTER 6. ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. Select Voltage&Phase 240 1-phase Select Voltage&Phase DC LABEL PLACEMENT: 9.01 AMPS MODULE SHORT CIRCUIT CURRENT. CONDUIT JUNCTION BOXES WARNING 14.07 AMPS DERATED SHORT CIRCUIT CIRCUIT(690.8(a)&690.8(b)). DC Voltage (Use Vmp,DVoltage (Use leaveeg ` I ,,I�,I ELECTRIC SHOCK HAZARD string Vmp,otherwise otherwise f _ Il -��� %,7P leave blank for AC) blank for AC) DO NOT TOUCH TERMINALS 368.4 LABEL PLACEMENT: TERMINALS ON BOTH LINE AND MODULE CHARACTERISTICS Enter Distance to Load ALL DISCONNECTS LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION (ft) 10 Enter Distance to Load (ft) 100 LABEL PLACEMENT: REC SOLAR: REC260PE(BLK) 260 W Enter Load (Amps) 17 Enter Load (Amps) 15 AC DISCONNECTS OPEN CIRCUIT VOLTAGE 37.8 V OUTPUTS OUTPUTS WARNING OPEN CIRCUIT VOLTAGE: (690.7) 41.1 V Voltage Drop (Volts) 0.4.2 Voltage Drop (Volts) 3.73 ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS MAX POWER VOLTAGE 30.7 V % Voltage Drop 0.18 % Voltage Drop 1.55 PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED VARIABLES VARIABLES SHORT CIRCUIT CURRENT 9.01 A Phase Factor 2 Phase Factor 2 LABEL PLACEMENT: SHORT CIRCUIT CURRENT(690.8(A)(1)) 11.26 A K 12.9 K 12.9 JUNCTION BOXES,COMBINER BOXES, DISCONNECTS 1 Q-Factor Q-Factor 1 Circular Mils 10380 Circular Mils 10380 SUNRUN,INC. 3380SE20TH,PORTLAND,OR97202 332 R. MORGAN SUNRUN PROJECT NUMBER: BARBEE RESIDENCE REV:A sunrun OR CL#180464 PH FAX 503 705-07 38 DESIGNER: FAX 503205-0748 BARBEL 601 R-240BARB 12240 SW WHISTLERS LN, TIGARD, OR 97223 ELECTRICAL PV-03 9/11/2014 0 DRAFTER: VELAZQUEZ ( ) NOTES: REVISION: — 5/16" LAG BOLTS MUST EMBED — 2.5" INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT — TORQUE ALL 5/16" HARDWARE TO ON TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT • COMPOSITION L FOOT — SILVER S.S. 10-16 FT—LBS CAN BE MOUNTED IN 5 S.S. FLANGE NUT — BLACK S.S. 7-9 FT—LBS STEP 2: SLIP FLASHING OVER ANY ORIENTATION — RAILS CAN MOUNT TO EITHER SIDE L FOOT BASE AND UNDER ROW X 1" (OR 1.25") OF L FOOT (UPSLOPE VS DOWNSLOPE) OF SHINGLES ABOVE SNAPNRACK S.S. BOLT AND v CHANNEL NUT SPLIT WASHER / \ �. TE S.S. LAG SCREW - .„...1/4.011 .._ WITH FLAT WASHER SNAPNRACK � 2 ,, l'A 2.5" MINIMUM EMBEDMENT STANDARD RAIL IS STANDARD - SNAPNRACK COMPOSITION ROOF FLASHING qSTEP 1: BOLT L FOOT \, BASE TO ROOF WITH LAG BOLT J i SNAPNRACK L FOOT BASE ROOF DECKING TYP. 4,,,,\, ..., -. - ROOF DECKING TYP. FLASHED L FOOT MOUNTING POINT FOR �� USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3" USING UP TO TWO LEVELING SPACERS AS SHOWN IN "SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION , RAFTER TYP. SU U�LI n n���n A MAINSTREAM ENERGY CORP. DESIGNER: G McPheeters SCALE: DNS PART NUMBER: DESCRIPTION: REV // \{�LJ�\i Ilj�j] 775FIEROLANE,SUITE 200••SANLUIS(BIjPO,CA 93401 USA D Ryan PEN DETAIL 01, FLASHED L FOOT TO C -`J/) PHONE 805 528-9705••FAX 805 528-9701 DRAFTER: Y S100 PEN D01 f pv uG�lI©O 110 jcj ns j Brats= os«o�aEOR ,Fals,ME R���oa��T zIzzo EMOF " APPROVED BY: DATE: 120113 RAFTER