Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
PITCH: 18 0 PITCH:18 (..9" MP1 AZIMUTH: 180 ARRAYAAZIMUTH: 180 ° 0MATERIAL: Comp Shingle STORY: 1 Story LC (--M PITCH: 18 ARRAY PITCH:18 MP2 AZIMUTH:90 ARRAY AZIMUTH:90 AC °° (1111 4/111 IAC 0 MATERIAL:Comp Shingle STORY: 1 Story I-" PITCH: 18 ARRAY PITCH:18 1 MP3 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL: Comp Shingle STORY: 1 Story 3'Fire Setback 3'Fire Setback O O 0 09 To 0 O o B r7)Oil c O O I O O O to O 0 I 0 0 4-- <4129— ch (E) DRIVEWAY o 0 00 o v)u I to I ! LLLL d , poi , O o 0 1NfV ' o ° II—. ` LEGEND 1 ► E ® (E) UTILITY METER & WARNING LABEL I N INVERTER W/ INTEGRATED DC DISCO ® & WARNING LABELS Dc DC DISCONNECT & WARNING LABELS ZI� ATsACHMEN'rs SHALL O F SPACED NO 4>1!:> GREATER THAN 24 INCHES ON CENTER• ER IN ANY DIRECTION WHERE ARRAY is v-1 AC DISCONNECT & WARNING LABELS 12"Fire Setback LOCATED WITHIN 3 FEET OF A ROOF EDGE, HIP, EAT OR AIDC`. O DC JUNCTION/COMBINER BOX & LABELS OSISC 306.4.3'B 0 0 0 0 0 0 O° DISTRIBUTION PANEL & LABELS 0 0 0 0 0 C o O LC LOAD CENTER & WARNING LABELS iz F^ 0 0 0 0 0 o M ITEPV YTEME 0 0 0 0 0 0 0 o CSD D LOCATIONS ! (1, MP1 CONDUITCARUN ON EXTERIOR R CONDUIT RUN ON INTERIOR ° A — GATE/FENCE ° 0 HEAT PRODUCING VENTS ARE RED °c r,z.1 7 It '! INTERIOR EQUIPMENT IS DASHED D . L2_1 7r °n SITE PLAN N DR.) TOTAL ARRAY AREA (SF): 719 Scale: 1 8" = 1' °a TOTAL ROOF AREA (SF): 1984 w �, E ° TOTAL ARRAY AREA IS a 36.25 0 1' 8' 16' `+ PERCENT OF TOTAL ROOF AREA .■-mmEmmilmiimmm S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9722056 0 0 PRo,SE OWNER: DESCRIPION: DESIGN: CONTAINED SHALL NOT BEFO USED FOR THE LIVENGOOD, TONY W. LIVENGOOD RESIDENCE Brady Gilchrist �Nl:'5oIaiCjtyBEBENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNING SYSTEM: 10151 SW JEFFERSON ST qNOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Te C !0.2 KW PV ARRAY PART TOZ OTHERSN, DEIN THE RECIPIENTS TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION HATH MODULES NE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 3055 q�wew Way SALE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: REV DATE Sm Mateo,CA 94402 PERMISSION OF SOLARCITYMENT, YINC. MultipleTER: Inverters 5038872878 T:(650)638-1028 F:(650)638-1029 SITE PLAN PV 2 7/9/2014 (888)-SOL-CITY(765-2489) ,.sdarcity.cr, (E) 2x4 41) 0 ,... 04K (E) 2x4 -/ PRE—MANUFACTURED TRUSS • \/ PRE—MANUFACTURED TRUSS UCTURE MEETS THE N STRUCTURE MEETS THE 'I it PRESCRIPTIVE STREQUIREMENTS /-2' I! 6'-11" / 7'-2" / PRESCRIPTIVE REQUIREMENTS 2 6'-3" / 6' / OF THE OSISC SECTION 305.4 OF THE OSISC SECTION 305.4 (E) LBW r (E) LBW r SIDE VIEW OF MP1 NTS B SIDE VIEW OF MP2 NTS A M P2 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" STAGGERED LANDSCAPE 72" 24" STAGGERED PORTRAIT 48" 20" TOP CHORD 2x4 @ 24"OC ROOF AZI 90 PITCH 18 STORIES: 1 PORTRAIT 48" 20" ARRAY AZI 90 PITCH 18 ROOF AZI 180 PITCH 18 BOT CHORD 2x4 @24"OC Comp Shingle TOP CHORD 2x4 @ 24" OC ARRAY AZI 180 PITCH 18 STORIES: 1 BOT CHORD 2x4 @24" OC Comp Shingle ® PV MODULE \ (E) 2x4 "5 16BOLT WITH LOCK / INSTALLATION ORDER & FENDER WASHERS \ LOCATE RAFTER, MARK HOLE • PRE—MANUFACTURED TRUSS ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT " ZEP ARRAY SKIRT (6) —. HOLE. k STRUCTURE MEETS THE SEAL PILOT HOLE WITH 2' 6'-3" / 6' / PRESCRIPTIVE REQUIREMENTS ZEP COMP MOUNT C - (4) (2)I POLYURETHANE SEALANT. I OF THE OSISC SECTION 305.4 .friN N►� I I I.� *1M�1rI":0110101101011 (E) LBW ZEP FLASHING C I `!'rIli. ? I, PIL C INSERT FLASHING. SIDE VIEW 0 F MP3 NTS (E) COMP. SHINGLE .,-.2........—B-:167:�— '�� ••"4., PLACE MOUNT. 0 (E) ROOF DECKING WWI INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) (5) SEALING WASHER. MP3 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH LANDSCAPE 72" 24" STAGGERED (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. PORTRAIT 48" 20" (E) RAFTER ROOF AZI 270 PITCH 18 01) TOP CHORD 2x4 @ 24" OC ARRAY AZI 270 PITCH 18 STORIES: 1 STAN DOFF BOT CHORD 2x4 @24" OC Comp Shingle Scale: 1 1/2" = 1' CONFIDENTIAL- NE INFORMATION HEREIN JOB NUMBER: JB-9722056 00 PREMISE O DESCIIPIION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE LIVENGOOD, TONY W. LIVENGOOD RESIDENCE Bradyilchrist , t. BENEFITRSOF ITANYONE EXCEPT INSOLWHOLE INC., e srsTEAt ou �!'�SolarCity NOR SHALL IT BE DISCLOSED WHOLE OR IN Comp Mount Type C 10151 SW JEFFERSON ST 10.2 KW PV ARRAY Pik PART TO OTHERS OUTSIDE THE RECIPIENTS TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 Clean/few Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 91VERTER• PAGE NAME: SHEET: REN DATE: San Mateo,CA 94402 PERMISSION OF SOLARaTY INC. Multiple Inverters 5038872878 L(650)638-1028 F:(650)638-1029 STRUCTURAL VIEWS PV 3 7/9/2014 (888)—s0L—alY(765-2489)nh..solardtyaam UPLIFT CALCULATIONS1 1 07.09.2014 % ,,SolarCity, SleekMountTM PV System Version#37.4 Structural Desian Software "reject-information&TSS Of Contents Risk Category: II PV System Type SolarCity SleelcMount" Comp Roof Comp Roof Layers of Comp Roofing Roof Slope 18° Rafter SPadrt9 24"O:C. PV System Module Orientation Landscape and Portrait PV Module Area 705 s PV Module Width 39" PV Module Length` '" Standoff(Attachment Hardware) Comp Mount Type C Reduced Ground/Roof Live/Snow Loads Ground Snow Load pg 25.0 psf •ASCE Table 7-1 Swroundiiig;Roof Snow 100% 25.0 psf 'ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 %Via Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Put:taly/Fully Enclosed Method Basic Wind Speed V 95 mph ' Fig.6-1 CExposure Catepow ' Section 6.5.6.3 Roof Style Gable Roof 'Fig.6-11.e/C10-14A'B Mean Roof Height h 15 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Co dental Wind Pressure Exposure Kz 0.85 Table 6-3 Topographic Factor Kzt 1.00 Section 6:5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 10 Tabled Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(n Equation 6-15 16.7 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 FIg.6-11a/C/D-14A/B Ext Pressure Coefficient(Dawn) GCP(Mown) 0.45 r-g:s-:ie/rgD-140 Design Wind Pressure P p=qh(GCp) Equation 6-22 Wind Pressua thi 0(4) -14.6 psi Wind Pressure Down p(down) 10.0 psf Allowable Spacings X-Dwedion Y-Dinectiulr Max Allowable Standoff Spadng Landscape 72" 39" Max Allowable( ntilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Upit at Standoff T-actual -252 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff D nd/Caped DCR 503% Max Allowable Standoff Spacing Portrait 48" 65" Max Allowable Cantilever Portrait 20" NA Standoff Configuration Portrait Staggered Max Stands f Tributary Area Trlb 22 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff T-actual 279 lbs Uplift Capacity of Standoff T-allow 500 lbs Standoff Dernand/CapaditY DGR 55.8% CONFIDENTIAL— THE INFORMATION HERJB-9722056 00 PREMISE ONS: DESCRIPTION: DESIGN: HERON JOB LIVENGOOD, TONY W. ��'ai. ■ CONTAINED SHALL NOT BE USED FOR THE LIVENGOOD RESIDENCE Brady Gilchrist �Solarc�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM 10151 SW JEFFERSON ST �h% NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 10.2 KW PV ARRAY iii " PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES ORGANIZATION, EXCEPT IN CONNECTION NATH TIGARD, OR 97223 THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 3055 aearwerr Way E SHEET: REV DALE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAM NVERTER: PERMISSION OF SOLARCITY INC. Multiple Inverters 5038872878 UPLIFT CALCULATIONS PV 4 7/9/2014 (888)—SOL—CITY(765-2 489)� I c�aam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE _ BOND (N) #8 GEC TO TWO (N) GROUND Panel Number: Inv 1: DC Ungrounded INV 1 -(1)POWER-ONEAURORA PVI-4.2-0UTD-S-US-Z-A RINA SOLAR ¥¥ TSM-255PA05.18 OR # 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24309343 Inv 2: DC Ungrounded FCI Inverter; rigbee 4200W, 240V, 96% LABEL A -(40)TPV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 Overhead Service Entrance INV 2 -(1)POWER-ONE#AURORA PN-3.0-0UTD-S-US-Z-A LABEL: B FCI Inverter; Zigbee 3000W, 240V, 96% Voc: 37.7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER N 200A MAIN SERVICE PANEL - N 175A/2P MAIN CIRCUIT BREAKER (E) WIRING BRYANT Inverter 1 IND CUTLER-HAMMER COOPER (N) 125A Load Center 175A/2P Disconnect Meter Socket n 0 POWER-ONE DC+ DO NOT ADJUST MIN.ACTIVATIONVTACE n • AURORA PVI-4.2-OUTD-S-US-Z-A DG 1 String(s)Of 12 On MP 1 4 (E) LOADSID A B C 25A/2P EGC goio i L2 / -— DC+ I DC+ DO NOT ADJUST MIN.ACTIVATION V TAGS Ell NDC- 50A 2� ———_ GND __ __ _ GND —— , —i i——— GEC I� 1 '— DG 2 DC- 1 String(s)Of 12 On MP 1 i i I I = T..11../.1-Th. I I GND I—___EGC--- ----f---1(1)Conduit - EGC J I }_-----J L I I (1)Conduit Kit; 1" EMT N Inverter 2 IND T J Q_ EGC/GEC i © POWER-ONE DC+ DO NOT ADJUST MIN.ACTIVATION V TAGS Z- I EGC J I AURORA PVI-3.0—OUTD—S—US—Z—A DC- / 1 String(s)Of 7 On MP 1 20A/2P / /// --- GEC r 1 _.rte• - LI F- --t TO 120/240V I 1 I �- L2 •_--- DC* SINGLE PHASE I I I �� I N i_e_--- DG I (4�x DO NOTADJUST MIN.ACTIVATION V TAGS UTILITY SERVICEL_r r` GEC/ ---T� .�Dc+ Dc+ /)NImo'-DG---J ---- DG 1Strin9(s)Of9OnMP2 I I GND EGC llllll--- m__- - - I EGC J 1 I +� (1)Conduit Kit; 1" EMT _1_J- Voc* = MAX VOC AT MIN TEMP POI—(1)CUTLER—HAMMER#BR250 PV BACKFEED BREAKER A —(1)CUTLER—HAMMER /DG222URB Breaker, 50A 2P, 2 Spaces Disconnect; 60A, 24OVac, Non-Fusible, NEMA 3R AC -(2)Ground Rod; 5/8"x 8', Copper -(1)CUTLER-HAMMER DG100NB D C C 1—(1)BRYANT#BR816L125RP Ground leutrol Kt 60-100A, General Duty(DG) Load Center; 125A, 120/240V, NEMA 3R B (1)COOPER#B-Line Meter Socket 011 -(1)CUTLER-HAMMER#BR225 Meter Socket; 125A, 4-14AWG, Ring Type Breaker; 25A/2P, 2 Spaces -(1)AW CAP; B-Line Meter Socket Accessory -(1)CUTLER-HAMMER #BR220 -(1)MILBANK /CL200 Breaker; 20A/2213, 2 Spaces Meter; FORM 2S (1)AWG#8, THWN-2, Black —(1)AWG#10, THWN-2, Black —(2)AWG#10, PV WIRE Black Voc* =507.41 VDC Isc =8.92 ADC- §-(1)AWG#8, THWN-2,Red 5 (1)AWG#10, THWN-2, Red (--1-) ao (1)AWG#8, THWN-2,White NEUTRAL Vmp =240 VAC Imp=34.5 MC O (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 MC O -(1)Con #6,KitSt3/4d Bare Copper EGC Vmp =366 VDC Imp=8.36 ADC -(1)AWG#8, THWN-2, Green EGC/GEC-(1)Conduit Kit 3/4"EMT -(1)AWG#8,,TH•WN-2,.Green . EGC/GEC,-(1)Conduit,Kit;_3/4'.EMT.. . . . , (1)Conduit 3/4"EMT •• —(2)AWG#10, PV WARE, Black Voc* =507.41 VDC Isc =8.92 ADC 6 _ (1)AWG#10, THWN-2, Black 2 00 (1)AWG#6, Stranded Bare Copper EGC Vmp =366 VDC Imp=8.36 ADC (1)AWG#10, THWN-2, Red O (1)Conduit Kit 3/4"EMT ---(1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 MC —(2)AWG#10, PV WIRE Black Voc* =295.99 VDC Isc =8.92 ADC -(1)AWG#8, THWN-2, Green EGC/GEC-(1)Conduit Kit; 3/4"EMT (1-) -4-(1)AWG#6, Stranded Bare Copper EGC Vmp =213.5 VDC Imp=8.36 ADC '—(1)Conduit Kit 3/4"EMT —(2)AWG#10, PV WIRE, Black Voc* =380.56VDC Isc =8.92 ADC ® -s. #6, Stranded Bare Copper EGC Vmp =274.5 VDC Imp=8.36 ADC (1)Conduit Kit: 3/$EMT CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: UB-9722056 0 0PREMISE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE LIVENGOOD, TONY W. LIVENGOOD RESIDENCE Bradyilchrist 11 BENEFIT OF ITANYONE EXCET SOIN RCITY INC., MOUNTING ompSYSou 10151 SW JEFFERSON ST SolarCity NOR SHALL IT DISCLOSED IN WHOLE OR IN Comp Mount Type C 10.2 KW PV ARRAY PART 1 TO OTHERS OUTSIDE THE RECIPIENT'S MODULES ORGANIZATION, EXCEPT IN CONNECTION NTH TIGARD, OR 97223 3055 CIearvle.Way THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV DATE 1:(650)San 638-1028 CA 94402 636-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters 5038872878 THREE LINE DIAGRAM PV 5 7/9/2014 (888)-SOL-CITY(765-2489). .i.edarcitycom ELECTRICAL CALCULATIONS Module: 24 Canadian Solar CS6P-255PX 234.3 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 6_0.8 lnverter 1: 1 Power-One PVI-4.2-S AFCI 96.0% 4,600 5,398 Vdrop= (Imp) * (2*Length)*(Resistance) / (Vmp) Module: 16 Canadian Solar CS6P-255PX 234.3 Imp(A) Max.Length(ft) Wire Inverter 2: 1 Power-One PVI-3.0-S AFCI 96.0% 3,300 3,599 String: 8.43 30 C AWG 10 at Max Are Hi: 80 deg F Module: Vdrop= (8.43 A * 60 ft *0.00124 Ohms) / 229 V= 0.27% Inverter 3: Branch: 8.43 I 80 I C AWG 10 at Max Are Hi: 80 deg F Module: Vdrop= (8.43 A * 160 ft *0.00124 Ohms) / 229 V= 0.73% Inverter 4: Total voltage drop in DC conductors= 1.00% Inverter: I 14.50 I 80 I E AWG 06 at 240V Total: 40 modules Total Inv Pwr 7,900 8,997 PTC Vdrop= (14.50 A * 160 ft *0.00049 Ohms) / 240 V 0.47% Photovoltaic Module Electrical Specifications: Total STC 10,200 Combined 34.50 I 0 I E AWG 06 at 240V Voc= 37.4 V deg F deg C Vdrop= (34.50 A * 0 ft *0.00049 Ohms) / 240 V 0.00% Vmp= 30.2 V Record Low Temp: 8 -13.3333333 Total voltage drop in AC conductors= 0.47% Isc= 9 A Max Average Hi Temp: 80 26.66666667 Total voltage drop in AC and DC conductors= 1.48% Imp= 8.43 A Record Hi Temp: 106 41 Tvoc= -0.12716 V/deg C Power-One Strings: Individual MPPT Trsc= 5.85 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1-way wire length: 80 ft Power-One PVI-3.0-S AFCI 1 strings per branch 1 1 strings per branch 2 9 Canadian Solar CS6P-255PX Inverter Min Vdc Input: 120 Vdc 9 modules per series string 7 modules per series strip Voc= 336.6 V Min Vmp at Max Temp: 212 Vdc Voc= 336.6 V 261.8 V Vmp= 271.8 V Max Voc at Min Temp: 380 Vdc Vmp= 271.8 V 211.4 V Isc= 9 A Inverter Max Vdc Input: 600 Vdc Isc= 9 A 9 A Imp= 8.43 A Max String Size: 14 Imp= 8.43 A 8.43 A Icont= 11.25 A Art 690.8(A)(1) 1-way wire length: 30 ft Icont= 11.25 A 11.25 A Art 690.8(A)(1) 1.a Conductor:C AWG 10 PV Wire 2.a Conductor 1:C AWG 10 Conductor 2:C AWG 10 Conductor 1:Conductor 2: Icont'1.25=(Amps) 14.06 Icont*1.25=(Amps) 14.06 14.06 30 deg C ampacity= 40 I 30 deg C ampacity= 40 40 I 1.b Icont=(Amps) 11.25 2.b Icont=(Amps) 11.25 11.25 Start ampacity 40 Start ampacity 40 40 Temperature derate(%=F) 0.76 Temp.derate(%=F) 0.71 0.71 Conduit fill derate(%=#) 0.7 Cndt.fill derate(%=#) 0.8 0.8 Derated ampacity 21.28 Derated ampacity 22.72 22.72 Term 1 Term 2 1.c Icont*1.25=(Amps) 14.06 Temp table 90degC 90degC Ampacity 40 2.c Icont*1.25=(Amps) 14.06 14.06 Ampacity 40 40 I 1.d Icont*1.25=(Amps) 14.06 2.d EGC C AWG 10 C AWG 10 Art.250.122 OCP size= 15 OCP size= 15 15 Inverter Type A Output Combined Inverter Output Power-One PVI-3.0-S AFCI 1-way wire length: 80 ft Service Voltage= 240 Volts lcont= 14.50 A Art 690.8(A)(1) Total Inverter Power= 7,900 Nameplate Watts 1-way wire length: 0 ft 3.a Icont*1.25=(Amps) 18.13 A Art 690.8(6)(1) Icont=#of inverters*max inverter current Art 690.8(A)(1) OCP size= 20 A Art.240.6(A) (cont=(Amps) 34.50 3.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.15(6)(16) 4.a Icont*1.25=(Amps) 43.13 A Art 690.8(B)(1) Icont*1.25=(Amps) 18.13 OCP size= 50 A Art.240.6(A) 30 deg C ampacity= 75 I 4.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.15(6)(16) 3.c Icont=(Amps) 14.50 Icont*1.25=(Amps) 43.13 Start ampacity 75 30 deg C ampacity= 75 Temperature derate(%=F) 0.91 4.c Icont=(Amps) 34.50 Conduit fill derate(%=#) 1 Start ampacity 75 Derated ampacity 68.25 Temp.derate(%=F) 0.91 3.d Icont*1.25=(Amps) 18.13 Cndt.fill derate(%=#) 1 Ampacity 65 Derated ampacity 68.25 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3),250.166(6) 4.d Icont*1.25=(Amps) 43.13 Ampacity 65 I CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: UB-9722056 0 0 PRDASE OWNER DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE LIVENGOOD, TONY W. LIVENGOOD RESIDENCE Bradyilchrist 611.‘"501 `+a . NOR SHALEFIT L ITYONE EXCEPT SOLARCITY BEDISCLOSED IN WHOLE ORC.. MOUNIING IN CompsMou: 10151 SW JEFFERSON ST � SoIarCityPART TO OTHERS OUTSIDE THE RECIPIENTS Mount Type c 10.2 KW PV ARRAY �� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97223 THE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INvER PAGE NAME: SHEET: REN DATE: Sm Mateo, CA 94402 PERMISSION OF SOLARg1Y INC Multiple Inverters 5038872878 ELECTRICAL CALCULATIONS PV 6 7/9/2014 (888)-SOL-CITY 3 (7658-2�)�w w.solar10iycom ELECTRICAL CALCULATIONS Module: 24 Canadian Solar CS6P-255PX 234.3 Inv Pwr W PTC Strien Voltage Drop Calculations Version 6_0.8 Inserter 1: 1 Power-One PVI-4.2-S AFCI 96.0% 4,600 5,398 Vdrop= (Imp) * (2*Length)*(Resistance) / (Vmp) Module: 16 Canadian Solar CS6P-255PX 234.3 Imp(A) Max. Length(ft) Wire Inserter 2: 1 Power-One PVI-3.0-S AFCI 96.0% 3,300 3,599 String: 8.43 30 C AWG 10 at Max Ave Hi: 80 deg F Module: Vdrop= (8.43 A * 60 ft *0.00124 Ohms) / 305 V= 0.21% Inserter 3: Branch: 8.43 I 80 I C AWG 10 at Max Ave Hi: 80 deg F Module: Vdrop= (8.43 A * 160 ft *0.00124 Ohms) / 305 V= 0.55% Inserter 4: Total voltage drop in DC conductors= 0.75% Inverter: 20.00 I 80 I E AWG 06 at 240V Total: 40 modules Total Inv Pwr 7,900 8,997 PTC Vdrop= (20.00 A * 160 ft *0.00049 Ohms) / 240 V 0.65% Photovoltaic Module Electrical Specifications: Total STC 10,200 Combined! 34.50 I 0 I E AWG 06 at 240V Voc= 37.4 V deg F deg C Vdrop= (34.50 A * 0 ft *0.00049 Ohms) / 240 V 0.00% Vmp= 30.2 V Record Low Temp: 8 -13.3333333 Total voltage drop in AC conductors= 0.65% lsc= 9 A Max Average Hi Temp: 80 26.66666667 Total voltage drop in AC and DC conductors= 1.41% Imp= 8.43 A Record Hi Temp: 106 41 Tvoc= -0.12716 V/deg C Power-One Strings: Individual MPPT Tisc= 5.85 mA/deg C I String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1-way wire length: 80 ft Power-One PVI-4.2S AFCI 1 strings per branch 1 1 strings per branch 2 12 Canadian Solar CS6P-255PX Inverter Min Vdc Input: 120 Vdc 12 modules per series string 12 modules per series strin Voc= 448.8 V Min Vmp at Max Temp: 283 Vdc Voc= 448.8 V 448.8 V Vmp= 362.4 V Max Voc at Min Temp: 507 Vdc Vmp= 362.4 V 362.4 V Isc= 9 A Inserter Max Vdc Input: 600 Vdc !so= 9 A 9 A Imp= 8.43 A Max String Size: 14 Imp= 8.43 A 8.43 A Icont= 11.25 A Art 690.8(A)(1) 1-way wire length: 30 ft lcont= 11.25 A 11.25 A Art 690.8(A)(1) 1.a Conductor.C AWG 10 PV Wire 2.a Conductor 1:C AWG 10 Conductor 2:C AWG 10 Conductor 1:Conductor 2: Icont*1.25=(Amps) 14.06 (cont*1.25=(Amps) 14.06 14.06 30 deg C ampacity= 40 30 deg C ampacity= 40 40 I 1.b lcont=(Amps) 11.25 2.b Icont=(Amps) 11.25 11.25 Start ampacity 40 Start ampacity 40 40 Temperature derate(%=F) 0.76 Temp.derate(%=F) 0.71 0.71 Conduit fill derate(%=#) 0.7 Cndt.fill derate(%=#) 0.8 0.8 Derated ampacity 21.28 Derated ampacity 22.72 22.72 I Term 1 Term 2 1.c Icont*1.25=(Amps) 14.06 Temp table 90degC 90degC Ampacity 40 2.c Icont*1.25=(Amps) 14.06 14.06 I Ampacity 40 40 1.d Icont*1.25=(Amps) 14.06 2.d EGC C AWG 10 C AWG 10 Art.250.122 OCP size= 15 OCP size= 15 15 Inverter Type A Output Combined Inverter Output Power-One PVI-4.2S AFCI 1-way wire length: 80 ft Service Voltage= 240 Volts Icont= 20.00 A Art 690.8(A)(1) Total Inserter Power= 7,900 Nameplate Watts 1-way wire length: 0 ft 3.a Icont*1.25=(Amps) 25.00 A Art 690.8(B)(1) Icont=#of inverters*max inserter current Art 690.8(A)(1) OCP size= 25 A Art.240.6(A) Icont=(Amps) 34.50 3.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.15(6)(16) 4.a Icont*1.25=(Amps) 43.13 A Art 690.8(B)(1) (cont*1.25=(Amps) 25.00 OCP size= 50 A Art.240.6(A) 30 deg C ampacity= 75 4.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.15(B)(16) 3.c Icont=(Amps) 20.00 Icont*1.25=(Amps) 43.13 Start ampacity 75 30 deg C ampacity= 75 I Temperature derate(%=F) 0.91 4.c Icont=(Amps) 34.50 Conduit fill derate(%=#) 1 Start ampacity 75 Derated ampacity 68.25 Temp.derate(%=F) 0.91 3.d Icont*1.25=(Amps) 25.00 Cndt.fill derate(%=#) 1 Ampacity 65 Derated ampacity 68.25 I 3.e EGC/GEC = D AWG 08 Art.690.47(CX3),250.166(B) 4.d Icont*1.25=(Amps) 43.13 Ampacity 65 I CONF1DEN11AL- NE INFORMATION HEREIN JOB NUMBER: UB-9722056 0 0PREINSE OAR: DESCRIPTION: DESIGN:CONTAINED SHALL NOT BE USED FOR NE LIVENGOOD, TONY W. LIVENGOOD RESIDENCE Brady �`a, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: Gilchrist SolarCityCom Mount T e C 10151 SW JEFFERSON ST �iNOR SHALL IT BE DISCLOSED IN WHOLE OR IN p yp 10.2 KW PV ARRAY /\\ PART TO OTHERS OUTSIDE NE RECIPIENTS ORGANIZA110N, EXCEPT IN CONNECTION WITH MODULES TIGARD, OR 97223 NE SALE AND USE OF THE RESPECTIVE (40) TRINA SOLAR # TSM-255PA05.18 3055 Mateo,aearview Way SOLARCITY EQUIPMENT, WITHOUT NE WRITTEN INVERTER: PACE NAME ' DAA' San T:(650)638-1028 F:(6836-1029 PERMISSION OF SOLARCITY INC. Multiple Inverters 5038872878 ELECTRICAL CALCULATIONS PV 7 7/9/2014 (888)-SOL-CITY(765-2489)www.solarcltycorn Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM ACA (AC) (P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC)(INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35 F Label Location: THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER-_ (DC)(INV) PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT CURRENT(Imp) A Per Code: UNGROUNDED AND INVERTER IS MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER —v NEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT _A Per Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION NEC 690.64.6.7 ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD.DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC _ A OPERATING CURRENT PHOTOVOLTAIC AC (AC)(P01) MAXIMUM AC v (C): CoAC D nduuit connect DISCONNECT Per Code: OPERATING VOLTAGE _ NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D) (P01) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR _ =����j 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED ■ San Mateo,CA 94402 IWHOLE OR IN PART TO OTHERS OUESE THE RECIPIENTSNORGANIZATION, SCj OR Label Set ,;"•Solat'CiT:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION TNTH THE SALE AND USE OF NE RESPECTIVE (888)-SOS-Cm(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WIIHWT THE WRITTEN PERMISSION OF SOLARCITY INC. o :% ZS Comp Edge Zone Calculations 1 of 40 ZS Comp Edge Zone Calculations 2 of 4 Zep So to r 5/28/13 Zep So to r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will varythe design variables to account for the worst case for each failure mode that is beingdown force spacing= g module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads design load landscape= 9.62 17.32 17.32 psf Uplift= 656 lbs Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - -Ro.Alf note:use 10 psf minimum Z,iPPIPP- Snow Calculations Attachment Spacing Calculations 85818 IA To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing „ OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load ,e;91 m,�'��� above 30 degrees. uplift spacing= fMr Roo module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 P=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 K,K, Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Exposure= C Roof Zone= Edge Zone Down Force Load Roof Pitch Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof K,= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf lorst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.75S 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 11471bs in landscape down force spacing= 39"x 32.46 s x 144 tz = 130" ortrait effective area= 21.7 ft2 p f f Plandscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ftz = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs landscape uplift spacing = 39"x 29.05 psf ft2 x 144-=83" 656 bs portrait uplift spacing = 65"x 27112 psf x 144 ftz = 54" 0 t ZS Comp Edge Zone Calculations 3 of 40 ZS Comp Edge Zone Calculations 4 of 4 ZepSolar r 5/28/13 5/28/13 p ZepSolar • Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing =-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing= -1.4545 x 32.46 psf+120.7273 =73" P5=C5 Pf Roof Pitch= 31 45 degrees Pf=0.7 Ce Ct I Pg Ce= 0.9 C5= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing=-1.7917 x 32.46 psf+118.58=60" I= 1.0 P5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° 27" 30° Lateral 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49; 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". landscape lateral spacing 2949 in p p g= 39"x 14.49 psf x 144 ft2 = 74" 292lbs portrait lateral spacing= 65"x 14.49 psf x 144 ft2 =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ft2 =48" • SolarCity SleekMountT"' - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed '" Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules s aesthetics while minimizing roof disruption and .Interlock and grounding devices in system UL 5. r Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visuallyappealing system.SleekMount as"Grounding and Bonding System" PP g y 40 Insert Comp Mount flashing under upper utilizes ZepCom atibleT"" modules with p •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs,effectively eliminating the Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions 0 Secure Leveling Foot to the Comp Mount using machine Screw 40 Place module 4_,1_ 0 Components # %__ 5/16"Machine Screw ,s <� Leveling Foot �.� 40 Lag Screw 9 41 Comp Mount 40 .. 0 Comp Mount Flashing OP y,1.4, Q„oMratie k.d • � SolarCit ;, SolarCity January 2013 �A%o LISTED ®;; • oa,,,Pr y® January 2013 .0.w, TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Peak Power Watts-Pm. 240 245 250 255 260 • 941mm Power Output Tolerance-Peru 1%) 0/+3 0/+3 0/+3 0/+3 0/+3 ./.,u"aloe o Maximum Power Voltage-Von(V) 29.7 30.2 30.3 30.5 30.7 BO% Maximum Power Current-IMre(A) 8.10 8.13 8.27 8.36 8.47 TSM - PA05.1 $ "APn o Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 a-Maxi: i"srnw"c"ole Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rim(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction of 4.5%a1200 W/m%according to EN 60904-1. E 0 0 3 -- 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 60 CELL Maximum Power-Pm.(Wp) 174 178 181 184 188 Maximum Power Voltage-Von(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE B°"nn."°"°rr A A Maximum Power Current-Ir.1FP(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME "°"n'""°rr Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 1% Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 812mm 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. 240-260W Back view POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA • Compatible with all major BOS components and system -I 11 solar cells Multicrystalline 156.156 mm(6 inches) designs Cell orientation 60 cells(6•10) 1 o v Module dimensions 1650 x 992.40 mm(64.95 x 39.05.1.57 inches) Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY tillGlass High transparency solar glass 3.2 mm(0.13 inches) Backsheet White � One of the industry's most trusted modules Frame Black Anodized Aluminium Alloy with Trinamount Groove rit • Over 2 GW sold across all major global markets O�V+37 • Field proven performance I-V CURVES OF PV MODULETSM-245 PA05.18 J-Box P 65orIP 67 rated O Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), 10.0 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9m_,gggW,ms em Connector Original MC4 7m 800W/m' Highly reliable due to stringent quality control 5m 600W/m' 172 As a leading global manufacturer • Over 30 in-house tests (UV,TC,HF,and many more) ;4m_ 00W/m' of nextgenerationphotovoltaic o \ TEMPERATURE RATINGS MAXIMUM RATINGS • In-house testing goes well beyong certification requirements am products,we believe close 200 200w/m' Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C "-- Temperature(NOCT) cooperation with our partners m 1 Maximum System 1000V DC(IEC)/ is critical to success. With local x.0.°0 to.. 2000 30m 1 40m Temperature Coefficient of P nz -0.43%/°C Voltage 600V DC(UL) presence around the globe,Trina is Volta e Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A able to provide exceptional service s Iv1 to each customer in each market Temperature Coefficient of Isc 0.047%/°C and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing 17 conditions of Trina as a strong,bankable E • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module(5400 Pa) 10 year Workmanship Warranty to building strategic,mutually I beneficial collaboration with 25 year Linear Power Warranty installers,developers,distributors (Please refer to product warranty for details) and other partners as the rn backbone of our shared success in CERTIFICATION M' driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY �' �''\ PACKAGING CONFIGURATION 10 Year Product Warranty•25 Year Linear Power Warranty1--"1 \'' Sp°s Modules per box:24 pieces Trina Solar Limited www.trinasolar.com A Modules per 40'container:672 pieces tools ISO i, C E t fr us premix Addiiiogal ;s usrm v yal v ue front Trinp „90% � r Solgr's o . .. linear Warrant o � 4� �`� E I Y • CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. + 809 '� ®2013 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to 00 rinasolar =�, 1 19 tr'nasolar chongewilhoutnotice. g p Smart Energy Together Years s to 15 20 25 Smart Energy Together _ ■ Trina Solar 0014er, PONer one 0 41 Renelvolle Eneryy Solulions Z TECHNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US Q I i C Nominal Output Power W 3000 3600 3300 3800 4200 0 Maximum Output Power W 3000 3300' 33002 3600 4000' 4000' 3300 3800 4200' 3000 4600' 4600' CC Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 208 240 277 'in* ttSIde(Dk, Number of Independent MPPT Channels 2 2 2 " 2 Maximum Usable Power for Each Channel W 2000 3000 '. 3000 3000 Absolute Maximum Voltage(Vmax) V 600 Start-Up Voltage(Vstart) V .....200(adj.120-350) Full Power MPPT Voltage Range V 160-530 120-530 - 140-530 140-530 Operating MPPT Voltage Range V 0.7xVstart-580(>=90V) Maximum Current Udcmaxl for both MPPT in Parallel A 20 32 32 32 Maximum Usable Current per Channel A 10 16 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20.0 20.0 20.0 Number of Wire Landing Terminals Per Channel 2pairs Array Wiring Termination Terminal block Pressure Clamp,AWG10-AWG4 t O!tp Side(Ad ..: ..:: •.u•rl i' Split Split Split ... Split '`` Grid Connection Type 10/2W 10/2W 10/2W 10/2W 10/2W 10/2W 10/2W 10/2W ",S _. /3W 0/3W 0/0/3w0/3W ` "f, ' AdjustableVoltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency Hz 60 w. Adjustable Grid Frequency Range Hz 57-60.5....... '1a a , Maximum Current(lacmax) Awns 14.5 14.5 12.0 17.2. 16.0 16.0 16.0 16,0 16.0 20.0 20.0 20.0 , `"'` LJ Power Factor >0.995. _.. The most common residential inverter is the ideal size for an average- ,' Total Harmonic Distortion At Rated Power % <2 Grid Winn TerminationT a Terminal block Pressure Clamp AWG10 AWG4 sized family home. This family of single-phase string inverter "i,, ar 9 rP FIs ...._.... complements the typical number of rooftopsolarpanels,allowing .t. input P YP� ..5 i, home-owners to get the most efficient energy harvesting for the . ReversePolerityProtecti°" res Over-Voltage Protection Type Varistor,2 for each channel size of the property.This rugged outdoor inverter has been designed PV Array Ground Fault Detection Pre start up Rlso and dynamx GFDi(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental '` Output Anti-Islandin Protection 9 Meets UL 1741/IEE1547 requirements conditions. External ACOCPD Rating Am, 20 20 15 25 20 20 20 20 20 25 25 25 ' Over-Voltage Protection Type Varistor,2I1..-L2/L,-0) One of the key benefits of the Uno family of single-phase inverters xii•• -ie.. "" � '- Maximum Efficiency % 96.9 97 97 97 is the dual input section to process two strings with independent -' CEC Efficiency 96 MPPT especially useful for rooftop installations with two different ' ` b ptio ••• t ' ' Night Time Consumption W s <0.6 orientations(ie East and West).The high speed MPPT offers real-time Stand By Consumption wms <B power tracking and improved energy harvesting. �< " tm , Q ... '6charactersu2lines LCD displayUser-Interface w Remote Monitoring(1xRS465 incl.) AURORA-UNIVERSAL(opt) The transformerless operation gives the highest efficiency of up to } ". .' ' Wired Local Monitoring nxRS485 incl.) PVI-USB-RS485 232(opt.),PVI-DESKTOP(opt.) ;'Tr rr s' Wireless Lowl Monitorin 97.0%. The wide input voltage range makes the inverter suitable to "5 PVI-DESKTOP(opt.)with PVIRADIOMODULE(opt) IOW power installations with reduced string size. Ambient Air Operating Temperature Range °F(°C) -13 to+140(-2S to+60)with derating above 122(50) j ***. Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) •! ; Relative Humidity %RH 0-100 condensing : .• Acoustic Noise Emission Level db(A)@1m <50 Maximum Operating Altitude without Derating ft(m) 6560(2000) Features Enclosure rating NEMA 4X • Cooling Natural Convection Dimensions(H x W x D) in(mm) 33.8 x 12.8 x'8.7(859 x 325 x 222) • Each inverter is set on specific grid codes which can be selected in the field Weight <a7.3(21.3) • Single phase output Shipping Weight lb(kg) <60(27.0) • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented Mounting System Wall bracket in different directions Trade size KOs:(2ea x 1/2")and Goodall Connections' (2ea x 1-1/4°,3 places side,front,rear) •Wide input range Side:(2)Plugged 3/4"openings,(2)Concentric EKOs 3/4,1" Back:(4)Concentric EKOs 3/4;1" • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting DC Switch RatingHPerContact) AN 25/600 • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance Isolation Level Transformerless(Floating Array) across the entire input voltage and output power range Safety and EMC Standard UL 1741,CSA C22.2 N.107.1-01,UL1998 UL1699B,FCC Part 15 Class B •Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions Safety Approval ,CSA,,, • Integrated DC disconnect switch in compliance with international Standards(-5 Version) �"�°"-� -'-" `'' - -' " ` - - •• " -- - -- Standard Warranty years 1p • RS-485 communication interface(for connection to laptop or datalogger) Extended Warranty years 15&20 •Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Swtich and Wiring Box PVI-3.000TDUS PVI3.6-OUTDUS PV13.8OUTD-US DVI-4.2-OUTDUS •Integrated Arc Fault Detection and Interruption(-A Version) Standard-With DC Switch and Wiring Box PVI-3.000TDS-US PVI-3.6-OUTD-S-US PVI-3.8-OUTD-S-US PVI-4.2-OUTD-S-US With DC Switch,Wiring box and Arc Fault Detector PVI-3.0-OUTD-S-US-A PVI-3.6-OUTD-S-USA PVI-3.8-OUTD-S-USA PVI-4.2-OUTD-S-US-A and Interrupter 'All data is subject to change without notice • AURORA UNO 1 'CapabiliryenabledatnominuiACaoltageandwahsufickntDfpoweracadable AURORA UNO 3 'When equipped with optional DC switch and Wiring Box