Plans (3) PITCH: 26 ARRAY PITCH:26
MP1 AZIMUTH:90 ARRAY AZIMUTH:90
MATERIAL: Comp Shingle STORY: 2+ Stories
/
/
/
/ 0 0 ivn ACHmEN r:--,, si-!A:v C?_ SPACED NO
/ o GREAT, Ri , HS ON CENTER
/ o O IN° -,.'i°a ..:., g�-. gad"`sr-i ARRAY IS
0 0 0 LOCATED VIATFON 3 FEET OF A ROW=
EDGE. HP, EVE OR MIDGE,
0 -
/4 0 ``)SIS;:306.,,.3,a€ +
/ ° ° °
/ 0 0
_ /
0 0 0
0-- Q LEGEND
ungocka Glia \ . ^ o 0
( M ) r\ o 0 0 (E) UTILITY METER & WARNING LABEL
a� ' mo O- 0 a, Un-Locko aed Gated
',Inv 'i �> 0 ___0 ® INVERTER W/ INTEGRATED DC DISCO
& WARNING LABELS
\0 m m
O1,
_� � ° m
® DC DISCONNECT & WARNING LABELS
�—
T
AC
.� AC DISCONNECT & WARNING LABELS
mm �j CTURE
° Ur GE 0 DC JUNCTION/COMBINER BOX & LABELS
�
rl ° OD DISTRIBUTION PANEL & LABELS
• ZU9
l4 ° 4
Lc LOAD CENTER & WARNING LABELS
O DEDICATED PV SYSTEM METER
O STANDOFF LOCATIONS
(E)DRIVEWAY CONDUIT RUN ON EXTERIOR
Front Of House --- CONDUIT RUN ON INTERIOR
GATE/FENCE
12969 SW Kostel Ln O HEAT PRODUCING VENTS ARE RED
r,,,
°t '° INTERIOR EQUIPMENT IS DASHED
L-'J
SITE PLAN N
TOTAL ARRAY AREA (SF): 371 Scale: 3/32" = 1' Oak
ROOF AREA (SF): 2695 w `+ E
TOTAL ARRAY AREA IS a 13.77 01' 10' 21'
•
PERCENT OF TOTAL ROOF AREA ■.-T� S
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9721867 0 0 PREMISE OMNER. DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED FOR THE SHINDE, HARSHAVARDHAN SHINDE RESIDENCE Aaron Banks ��ta •
BENEFIT OF ANYONE EXCEPT IN WHOLE
INC., MOUNTING SYSTEM: 12969 SW KOSTEL LN arC�ty.
Nat SHALL IT BE DISCLOSED IN WHOLE oR IN CompMount Type C with Lifter i•.•_
PART TO OTHERS OUTSIDE THE RECIPIENTS 5.25 KW PV Array ,A
ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES PORTLAND, OR 97224
THE SALE AND USE OF THE RESPECTIVE (21) CANADIAN SOLAR # CS6P-250PX 3055 Mateo,CleaCAw way
THESOLITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REV: DATE San F:(650)94402
PERMISSION SOLARCITY INC. POWER–ONE # AURORA PVI-5000–OUTD–US 5039562083 SITE PLAN PV 2 2/28/2014 T:(650)638-1028 638-1029
(888)-SOL-CITY(765-2489)www.aolarcity.eom
(E) 2x4
® (E) 2x4
./
lei
® 600,::
/ �, of_8,, PRE—MANUFACTURED TRUSS
(E) LBW STRUCTURE MEETS THE
filir1 — II
PRESCRIPTIVE REQUIREMENTS
6"
7-10" 5-10" 6'-5" SIDE VIEW OF MP1A NTS
1'-z'i (E) LBW A
PRE-MANUFACTURED TRUSS
SIDE VIEW OF MP1B NTS STRUCTURE MEETS THE MP1A X-SPACING ,X-CANTILEVER Y-SPACING =Y-CANTILEVER NOTES
B PRESCRIPTIVE REQUIREMENTS LANDSCAPE 48" 22" I STAGGERED
OF THE OSISC SECTION 305.4
MP1B X-SPACING I X-CANTILEVER Y-SPACING'Y-CANTILEVER NOTES PORTRAIT 24" 13"
LANDSCAPE 48" l 22" STAGGERED RAFTER: 2x4 @ 24" OC ROOF AZI 90 PITCH 26 STORIES:2+
PORTRAIT 24" 13" j ARRAY AZI 90 PITCH 26
RAFTER: 2x4 @ 24"OC ROOF AZI 90 PITCH 26 STORIES:2+
C.J.: 2x4 @24" OC
ARRAY AZI 90 PITCH 26 Comp Shingle
C.J.: 2x4 @24"OC Comp Shingle
PV MODULE
5/16" BOLT WITH LOCK INSTALLATION ORDER
& FENDER WASHERS (6)
ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE
ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT
_ ;Jimir i i IM�. lE - HOLE.
Ahm
(4) miS. -7-i; SEAL PILOT HOLE WITH
ZEP COMP MOUNT C
POLYURETHANE SEALANT.
ZEP FLASHING C (3) (3) INSERT FLASHING.(E) COMP. SHINGLE Ipumm;mis i
(4) PLACE MOUNT.
1.111.11(E) ROOF DECKING MILO]
(5) INSTALL LAG BOLT WITH
5/16" DIA LAG BOLT (5) SEALING WASHER.
WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES LEVELING FOOT WITH
(2-1/2" EMBED, MIN) (6) BOLT & WASHERS.
(E) RAFTER6 STANDOFF
Scale: 1 1/2" = 1'
•
CONFIDENTIAL— NE INFORMATION HEREIN JOB NUMBER: J B-9721 867 00 PREMISE OWNER: DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED FOR NE SHINDE, HARSHAVARDHAN SHINDE RESIDENCE Aaron Banks �c`!r
BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM SolarCity
. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C with Lifter 12969 SW KOSTEL LN 5.25 KW PV Array ►i%
PART TOZ OTHERSON, DEIN THE RECIPIENT'S 'ACMES: PORTLAND, OR 97224
ORGANIZATION, EXCEPT IN CONNECTION WITH
NE SALE AND USE OF THE RESPECTIVE (21) CANADIAN SOLAR # CS6P-250PX 3055 Qeandew Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV. DATE San Mateo,CA94402
PERMISSION OF SOLARCIIY INC. INVERTER: 5039562083 T:(650)638-1028 F:(650)636-1029
POWER—ONE # AURORA PVI-5000—OUTD—US STRUCTURAL VIEWS PV 3 2/28/2014 (888)—s —)gY9(165-248)www.eoIaralty.aom
2" MAX 2" MIN CLEAR SPAN UPLIFT CALCULATIONS
DIAMETERTO UNDERSIDE
0101
VENT SPANNING DETAIL - OF MODULE
02.28.2014
• NTS /--/ � SolarC�ty SleekMountT'" PV System Version#31.4
Structural Desian Software
/ 6" MIN. VENT Profect Xnforcnation&Table Of Cocom
SOLAR PANEL e / HEIGHT FROM TOP Risk Category: II
OF ROOF! G MATERIAL PV System Type Solaray SleekMount"
Comp Roof Comp Roof
,/ Layers of Comp Roofing 1
SOLAR MODULE j/� Roof Slope 26°
MOUNTING HARDWARE %� 24"0.0
SEE STANDOFF DETAIL PV System Module orientation landscape and Portrait
........
( ) PV Module Area 364 sf
N
�' Pv Module Width 39"
11, PV Module Length 64"
ROOFING MATERIAL A Standoff(Attachment Hardware) Comp Mount Type C with Lifter
Reduced Ground/Roof Live/Snow Loads
PLYWOOD 41 VENT PIPE Ground Snow Load pg 25.0 psf 'ASCE Table 7-1
Surrounding Roof Snow 100% 25.0 psf 'ASCE Eq:7.4-1
(E) RAFTER Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1
Wind Design Criteria
Wind Design Code ASCE 7-05
Wind Design Method Partially/Fully Enclosed Method
SPANNING PHOTOVOLTAIC MODULES OVER VENTS Basic Wind Speed V 95 mph ' Fig.6-1
Exposure Category C ' Section 6.5.6:3
Roof Style Gable/Hip Roof 'Fig.6-11a/go-14A/e
MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER 2007 CPC SECTION 906.1. Mean Roof Height h 35 ft Section 6.2
Effective Wind Area(1 Module) A 17.3 sf IBC 1509.7.1
2007 CPC SECTION 311.5 STATES 'NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE OR METHOD OF INSTALLATION THAT Wind Pressure Calculation Courts
. OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS IN AN AMOUNT GREATER Wind Pressure Exposure Kz 1.01 Table 6-3
THAN THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED Topograph1cFactor Kzt 1.00 Sedton6.5.7
PER SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL Wind LanceDirectFactor
Factor Kd 0.85 Table 6-4
NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. Lr►portanceFactor 1 10 Table 6-1
Velodty Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15
19.9 psf
EQUATIONS: Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-119/C1D-14A18
THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT, THAT IS Ext.Pressure Coefficient(Down) GCp(Down) 0,45 Fig.6-119/C/D-14N8
THE CROSS—SECTIONAL AREA OF THE VENT PIPE: Design Wind Pressure p p=qh(GCp) Equation 6-22
Avent = 7r*R' Wind PressureUp P(up) -17.5 psi
Wind Pressure Down p(down) 10.0 psi
WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE
Allowable Standoff SPadngs
BETWEEM THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER BETWEEN THE TOP OF THE VENT AND THE X-pig, y ifirectlon
BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALLY OVER THE Max Allowable Standoff Spacing Landscape 48" 39"
VENT. IN ACTUALITY, THE MODULES WILL BE TILTED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Max Allowable Carver Landscape 22" NA
Standoff Configuration Landscape Staggered
Agap = C*CLEARANCE = (TT*D)*D = (7T*2*R)*(2*R) = 4*7T*R2 4*7r'R2 > 7T*R2 Max StandoifTrtbutary Area TrHh 13 sf
PV Assembly Dead Load W-PV 3 psi
FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS FOUR TIMES THE AMOUNT OF AIR FLOW Net Wind Uplift Capaacity dty at Standoff T aduai 204 lbs
of Standoff T-allow 500 lbs
ABOVE THE VENT THAN IN THE VENT ITSELF. Standdf Dennutd/Capacity DCR 408%
Max Allowable Standoff Spacing Portrait 24" 64"
VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. Max Allowable Cantilever' Portrait 13" NA
Standoff Configuration Portrait Staggered
MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE SOLAR MODULE GLASS SHALL BE AT LEAST THE DIAMETER OF Max StandoffTributary Area Trfb 11 sf
- THE VENT. PV Assembly Dead Load W-PV 3 psf
Net Wind Uplift at Standoff T-actual -170 lbs
IN THE DIRECTION OF THE SLOPE OF THE ROOF, THERE SHALL BE A GAP OF AT LEAST 1/2 INCH BETWEEN MODULES. Uplift Capacity of Standoff T-allow 500 lbs
5tar►doff Detnandlfapadty DCR 34.194
THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF 10' OR THE PANELS MUST BE SLOPED AT A MINIMUM INCLINATION OF 10'.
CONFIDENTIAL- THE INFORMATION HERON JOB NUMBER: J[3-9721867 0 O PREMISE OWNER: DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED FOR THE SHINDE, HARSHAVARDHAN SHINDE RESIDENCE Aaron Banks •
•*,„BENEFIT SolarCit
NOR SHALL ITYONE EXCEPT BEDISCLOSED IN WHO E ORTY CIN MOUNTING
SYso 12969 SW KOSTEL LN =-.J
PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C with Lifter 5.25 KW PV Array 11‘ y
ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES PORTLAND, OR 97224
THE SALE AND USE OF THE RESPECTIVE (21) CANADIAN SOLAR # CS6P-250PX 055 aeaniew Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME: SHEET: REN DATE San Mateo,CA 94402
PERMISSION OF SOLARCITY INC. 5039562083 T:(650)s -,o28 F:(650)r> -,a29
POWER—ONE # AURORA PVI-5000—OUTD—US UPLIFT CALCULATIONS PV 4 2/28/2014 (888)-SOL-CITY(765-2489),r."..eolaraty.aam
GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE
BOND (N) #8 GEC TO (E) UFER AT PANEL Panel Number:Cutler—Hammer Inv 1: DC Ungrounded
INV 1 —(1)POWER—ONE # AURORA PVI-5000—OUTD—US LABEL: A —(21)CANADIAN SOLAR OR 180498
CS6P-250PX
WITH IRREVERSIBLE CRIMP Meter Number:23 151 045 Inverter; Zigbee 5000W, 240V, 96.5% PV Module; 250W, 227.6W PTC, Black Frame, MC4, ZEP Enabled RGC, CGC1
INV 2
Voc: 37.2 Vpmax: 30.1
INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
(E 200A MAIN SERVICE PANEL ^
E) 200A/2P MAIN CIRCUIT BREAKER Inverter 1 IND
(E) WIRING COOPER
200A/2P Meter Socket () POWER—ONE n DC+ DO NOT ADJUST MIN.ACTIVATION V TAGE
AURORA PVI-5000—OUTD—US ', DC- 1 String(s)Of 10 On MP 1
• (E) LOADS •A _ EGC /
I • . u r t J
~F— Lz •..__ DC+ I
N
la
30A/2P _-�_ GND r-T i EGG/ ---- e� DC+ I 2 DC+ DO NOT ADJUST MIN.ACTIVATION V TAGE
•A
m i� 9 I GEC i N —0� DC- i__ DC- 1 Stnng(s)Of 11 On MP 1
I I GND I EGC _---f --- I EGC J
I
(1)Conduit Kit; 1' EMT
N
J EGC/GEC J
Z-Z
C,
GEC -,
TO 120/240V I
SINGLE PHASE
UTILITY SERVICE I
III
. I
Voc* = MAX VOC AT MIN TEMP
POI—(1)CU z-ruAMMFR#BR230 30A /2P BREAKER A —(1)CR/B—Line Meter Socket 011 AC DC
—(Breaker, 30A 2P, 2 Spaces Meter Socket; 125A, 4-14AWG,Ring Type
1 AW CAP; B—Line Meter Socket Accessory
—(1)MILBANK 1 CL200
Meter; FORM 2S
-
(1)AWG X10, THWN-2, Black -
3 (1)AWG 1110, THWN-2, Red (2)AWG/10, PV WIRE, Black Voc* =420.32VDC Isc =8.87 ADC
low„,)AWG#6, Stranded Bore Copper EGC Vmp =301 VDC Imp=8.3 ADC
(1)AWG p10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=23 MC (1)Conduit Kit; 3/4'EMT
—(1)AWG#8, THWN-2, Green EGC/GEC—(1)Conduit Kit; 3/4'EMT (2)AWG/10, PV WIRE, Black Voc* =462.35VDC Isc =8.87 ADC
O (1)AWG�, Stranded Bare Copper EGC Vmp =331.1 VDC Imp=$.3 ADC
(1)Conduit Kit; 3/4'EMT
CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9721 867 00 PREMISE OWER: DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED FOR THE SHINDE, HARSHAVARDHAN SHINDE RESIDENCE Aaron Banks ��`er •
BENEFIT OF ANYONE EXCEPT SOLARCITYEINC., MOUNTING SYSTEM: 12969 SW KOSTEL LN ...�SD�arC�ty
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C with Lifter
PART TO OTHERS OUTSIDE THE RECIPIENTS 5.25 KW PV Array r��
ORGANIZATION, EXCEPT IN CONNECTION 1MTH NODULES PORTLAND, OR 97224
NE SALE AND USE OF THE RESPECTIVE (21) CANADIAN SOLAR # CS6P-250PX 3055 Clearrier,Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE Son Mateo,CA 94402
PERMISSION OF SOLARCITY INC. INVERTER: 5039562083 T:(650)638-1028 F:(650)638-1029
POWER-ONE # AURORA PVI-5000-OUTD-US THREE LINE DIAGRAM PV 5 2/28/2014 (888)—SOL—CITY(765-2489)wrw.solareityeom
ELECTRICAL CALCULATIONS
' Module: 21 Canadian Solar CS6P-250PX-BF 227.6 Inv Power WPTC Voltage Drop Calculations Version 5_8.0
Inverter 1: 1 Power-One PVI-5000-S 0.965 5000 4612.31 Vdrop= Imp) * (2*Length)*(Resistance) / Vmp)
Module: 9 1 Imp(A) Max.Length(ft) Wire 1deg
Inverter 2: String: 8.3 75 AWG_10 at Max Ave Hi:87 F
Module: Vdrop= (8.3 *150 *0.00124Dhms) / 272.53314 0.62
Inverter 3: Branch: 18.3 I 50 I AWG_10 I at Max Ave Hi:87 deg F
Module: Vdrop= (8.3 *100 *0.00124Ohms) / 272.53314 0.42
Inverter 4: • Total voltage dro in DC conductors= 1.04
Inverter: 18.3 I15 AWG_10 1 at 24OV
Vdrop= (8.3 *30 *0.0 12 Ohms) / 240 V 0.1245
Total: 21 Modules Total Inv Pwr: 5000 4612.31 I PTC Combined 0 I 0 I AWG_10 I at 240V
Photovoltaic Module Electrical Specifications: Total STC: 5250 Vdrop= (0 *0 0.0012 Ohms) / 240 V 0
' Voc: 37.2 V deg F deg C
Vmp: 30.1 V Record Low Temp: 8 -13 Total voltage drop in AC conductors= 0.12
Isc: 8.87 A Max Average Hi Temp: 87 31 Total voltage drop in AC and DC conductors= 1.16
Imp: 8.3 A Record Hi Temp: 96 36
Tvoc: -0.12716 V/deg C
Tisc: 5.85 mA/deg C
String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 50
Voc Correction Factor:
Power-One PVI-5000-S 1 strings per branch 1 1 I strings per branch 2
Inverter Min Vdc Input: 130
11 Canadian Solar CS6P,250PX-BF 11 modules per series string 10 modules per series string
Min Vmp at Max Temp: 272.53
Voc= 409.2 Max Voc at Min Temp: 462.35 Voc= 409.2 V Voc= 372 V
Vmp= 331.1 Vmp= 331.1 V Vmp= 301 V
Inverter Max Vdc Input: 600
Isc= 8.87 Max String Size: 14 Isc= 8.87 A Isc= 8.87 A
Imp= 8.3 Imp= 8.3 A Imp= 8.3 A
Icont= 11.09 Art 690.8(A)(1) 1-way wire length: 75 Icont= 11.09 A Icont= 11.09 A Art 690.8(A)(1)
1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 PV Wire
Conductor 2: AWG_10 PV Wire
Icont*1.25=(Amps) 13.86 Conductor 1 Conductor 2
30 deg C ampacity= 40 Icont*1.25=(Amps) 13.86 13.86
1.b Icont=(Amps) 11.09 30 deg C ampacity= 40 40
Start ampacity 40 2.b Icont=(Amps) 11.09 11.09
Temperature derate(%=F) 0.76 Start ampacity 40 40
Conduit fill derate(%_#) 1 Temperature derate(%=F) 0.76 0.76
Derated ampacity 30.4 Conduit fill derate(%=#) 0.8 0.8
1.c Derated ampacity 24.32 24.32
Icont*1.25=(Amps) 13.86 2.c Term 1 Term 2
Ampacity 40 Temp table 75degC 75degC
Icont*1.25=(Amps) 13.86 13.86
1.d Icont*1.25=(Amps) 13.86 Ampacity 35 35
OCP Size= 15
Inverter Type A Output 2.d OCP Size= I 15 I 15 I
Power-One PVI-5000-S 1 way wire length: 10 ft Combined Inverter Output
Icont= I 23 I A Art 690.8(A)(1) Service Voltage=
3.a Icont*1.25=(Amps) 28.75 Art 690.8(6)(1) Total Inverter Power= 1 way wire length= 0
OCP Size= 30 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1)
3.b Conductor:)AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps)
Icont*1.25=(Amps) 28.75 4.a Icont*1.25=(Amps) 28.75 Art 690.8(B)(1)
30 deg C ampacity= 40 OCP size= 30 Art 240.6(A)
3.c Icont=(Amps) 23 4.b Conductor: I AWG_10 THWN-2 at 90 deg C:Table 310.16
Start ampacity 40 Icont*1.25=(Amps) 28.75
Temperature derate(%=F) 0.91 30 deg C ampacity= 40
Conduit fill derate(%=#) 1 4.c Icont=(Amps) 23
Derated ampacity 36.4 I Start ampacity 40
•
3.d Icont*1.25=(Amps) 28.75 Temperature derate(%=F) 0.91
Ampacity 35 Conduit fill derate(%=#) 1
Derated ampacity 36.4 I
4.d Icont*1.25=(Amps) 28.75
I Ampacity 35 I
CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: PREMISE OMER: DESCRIPTION: DESIGN:
CONTAINED SHALL NOT BE USED THE JB-9721867 O O =1:,
NEAT OF ANYONE EXCEPT SOLARCITYFOR INC., MouNTINc SYSTEM: SHINDE, HARSHAVARDHAN SHINDE RESIDENCE Aaron Banks ��`
SolarCityNOR SHALL IT BE DISCLOSED IN WHOLE aR IN Comp Mount Type C with Lifter 12969 SW KOSTEL LN 5.25 KW PV Array
PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULESPORTLAND OR 97224
ORGANIZATION, EXCEPT IN CONNECTION WITH r
THE SALE AND USE OF THE RESPECTIVE (21) CANADIAN SOLAR # CS6P-250PX 3055 gearNer Way
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN NVERTER PAGE NAME SHEET: REV DATE San Mateo,CA 94402
T:(650)638-1028 F:(650)638-1029
PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-5000-OUTD-US 5039562083 ELECTRICAL CALCULATIONS PV 6 2/28/2014 (888)-SOL-CITY(765-2489)www.eolarcity.com
Label Location: Label Location: Label Location:
CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC A (AC)(P01) CAUTION (P01)
Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code:
IFC 605.11.1.4 MAXIMUM AC _ v NEC 690.54 SECOND SOURCE IS NEC 690.64.6.4
• OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM
Label Location:
PHOTOVOLTAIC DC (DC)(INV)
DISCONNECT Per Code:
NEC 690.14.C.2 Label Location: Label Location:
PV SYSTEM (AC) WARNING (DC)(INV)
DISCONNECT FOR Per Code:
UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F)
Label Location: THE DC CONDUCTORS OF THIS
SYSTEM
MAXIMUM POWER- A (DC)(INV)
PHOTOVOLTAICUNGROUNDED AND ARE TO BE USED WHEN
- POINT CURRENT(Imp) Per Code: MAY BE ENERGIZED INVERTER IS
MAXIMUM POWER-_v NEC 690.53 UNGROUNDED
POINT VOLTAGE(Vmp)
MAXIMUM SYSTEMv Label Location:
VOLTAGE(Voc) WARNING (AC) (P01)
SHORT-CIRCUIT Per Code:
CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4)
DO NOT TOUCH TERMINALS
TERMINALS ON BOTH LINE AND
LOAD SIDES MAY BE ENERGIZED
IN THE OPEN POSITION 1
Label Location:
WARNING (DC)(CB)
Per Code:
ELECTRICAL SHOCK HAZARD NEC 690.17(4)
DO NOT TOUCH TERMINALS Label Location:
TERMINALS ON BOTH LINE AND WARNING (P01)
LOAD SIDES MAY BE ENERGIZED Per Code:
IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.6.7
• DC VOLTAGE IS CONNECTION
ALWAYS PRESENT WHEN DO NOT RELOCATE
SOLAR MODULES ARE THIS OVERCURRENT
EXPOSED TO SUNLIGHT DEVICE
Label Location: Label Location:
WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01)
Per Code: INTERCONNECTION Per Code:
ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54
IFA GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH
NORMALLY GROUNDED TERMINALS.TERMINALS ON
CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE
UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN
POSITION. FOR SERVICE
DE-ENERGIZE BOTH SOURCE
AND MAIN BREAKER.
PV POWER SOURCE
Label Location: MAXIMUM AC _ A
OPERATING CURRENT
PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC (AC): Disconnect
_ V (C)):: Conduit
DISCONNECT Per Code: OPERATING VOLTAGE (CB): Combiner Box
NEC 690.14.C.2 (D): Distribution Panel
(DC): DC Disconnect
(IC): Interior Run Conduit
Label Location: (INV): Inverter With Integrated DC Disconnect
CAUTION (D)(POI) (LC): Load Center
Per Code:
PHOTOVOLTAIC SYSTEM (M):NEC 690.64.B.4 (POI)Utility
Po nMeter
CIRCUIT IS BACKFED of Interconnection
CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR 014
THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED likevr�AI 3055 Cleaview Way
IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, San Mateo,CA 94402
EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Sc - OR Label Set �"�Solar�■�ty T:(650)638-1028
5-2489)www.solarcity.com
8:(650)638-1029
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (888)-SOS-cm(765-2
m
0 ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4
Zeo �, 5/28/13 5/28/13
p ZepSotar
This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing
spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load
calculations will vary the design variables to account for the worst case for each failure mode that is bein down force spacing=
g module width x design load
checked.
Wind Down Calculations
All variable the same as above except for roof pitch
General Design Information:
Roof Pitch
Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45
System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9
Comp Mount Allowable Loads GCN portrait= 0.4 0.9 0.9
Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf
Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf
Down Force= 1147 lbs ,„..`'Ro,1$I/ note:use 10 psf minimum
r .4► RIIII Snow Calculations
Attachment Spacing Calculations 85818 112 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and
Uplift Spacing „\ OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes
Allowable Uplift Load 'F\�`9j '0.�0,��P above 30 degrees.
upli f t spacing= module length or width x design load Farr ROG
EXPIRES: 12/31/14 Ground Snow Load= 30 psf
Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch
ASCE 7-05 Method 2 14 30
p=qh GCN Design Snow Load 29.11 25.98 psf
chi=0.00256 K,K, Kd VZ I (snow load spread over the length of the rafter)
Basic Wind Speed= 95 mph
Down Force Load Roof Pitch
Exposure= C Roof Zone= Edge Zone Combinations: 14 30
Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf
Gable/Hip Roof Kit= 1.0 per 6.5.7.2
D+W= 12.91 19.92 psf
forst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf
Roof Height= 30 GCN landscape= -1.6
iscape effective area= 13.0 ft2 GCN portrait= -1.5 landsca a down orce s acin 11471bs in
p f p g = x 144-= 130"
ortrait effective area= 21.7 ft2 39"x 32.46psf ftz
Plandscape= -30.79 psf
qh= 19.25 psf Pportrait= -28.87 psf
11471bs in
portrait down force spacing= 65"x 32.46psf x 144 ft2 =78"
Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7)
design load landscape= -29.05 psf
design load portrait= -27.12 psf
656 lbs
landscape uplift spacing = 39"x 29.05 psf x 144-=83"
• portrait uplift spacing = 65"x 2712 psf x 144-= 54"
ZS Comp Edge Zone Calculations 3 of 4 r ZS Comp Edge Zone Calculations 4 of 4
ZP. �`0 �r 5/28/13 5/28/13
P ZepSolar
Lateral Spacing Module Deflection Spacing
The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing=-1.4545 x Maximum Uplift or Down Force Pressure+120.7273
the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked
at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing =-1.7917 x Maximum Uplift or Down Force Pressure+118.58
Allowable Lateral Load
lateral spacing=
module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf
Snow Calculations
Ground Snow Load= 30 psf
landscape module spacing= -1.4545 x 32.46 psf+120.7273 = 73"
Ps=Cs pf Roof Pitch= 31 45 degrees
pf=0.7 Ce Ct l pg Ce= 0.9 C5= 0.71 0.45
Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing = -1.7917 x 32.46 psf+118.58=60"
I= 1.0 Ps= 16.1 10.2 psf
Calculation Summary
Calculated Edge Zone Spacing
Roof Pitch Spacing Check Landscape Portrait
27 30 31 45 Uplift 83" 54"
Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78"
(snow load spread over the length of the rafter) 30, 27` 30°
Lateral
• 74" 48" 45"
Lateral Force Component Module Deflection 73" 60"
Down Force Load Roof Pitch
Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30
D+S= 13.50 14♦49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in
D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48"
on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum
30 degree roof pitch attachment spacing is 45".
292lbs in
landscape lateral spacing = 39"x 14.49 psf x 144 ftz = 74"
292lbs in
portrait lateral spacing = x 144-65"x 14.49 psf tz =45"
Portrait spacing is less than 48".Try roof pitch of 27 degrees
292lbs in
portrait lateral spacing = 65"x 13.50 psf x 144 ftz =48"
SolarCity SleekMountTM - Comp SolarCity SleekMountl"" - Comp
The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions
is optimized to achieve superior strength and Zep CompatibleTM modules
• aesthetics while minimizing roof disruption and • Drill Pilot Hole of Proper Diameter for
labor.The elimination of visible rail ends and Interlock and grounding devices in system UL
listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2
mounting clamps, combined with the addition
of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant
to a more visually appealing system.SleekMount as"Grounding and Bonding System"
• Insert Comp Mount flashing under upper
utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle
strengthened frames that attach directly to grounding device
Zep Solar standoffs,effectively eliminating the • Place Comp Mount centered
need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing
standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3
shingles are not required to be cut for this
system,allowing for minimal roof disturbance. •Applicable for vent spanning functions \ \ • with sealing washer.
Secure Leveling Foot to the Comp Mount
,Ii
using machine Screw
• Place module
:,,i,;
Components
�%+� •_ 5:: a::&I1
� ��.,4, L , �'� ! UP ,
Op
• Lag Screw
® 41 Comp Mountw--'7
Comp Mount Flashing
® tom
/° ` :;
.`alI
eP
6 ift Qc•MP4.4 a1Edi
7.--'4
v �S^,
E Solari ity® January 2013 "^A W0 0 LISTED f ps SolarCity
CCMPPt� ® January 2013
n
m m < � c <� m�
fir,
m o A
o
o m'
105,6S'
O 03 `�� A
b 0� 3�
eo 3 c 3
O y
O 0. 7p
vAiN (
m
m
c ?
to
<
b C
d
b r
A
c $
os
r�
gab
m
v ! :3a
fD
p
SO€3
sp Z
a tD
v
r
m p
O A
a
N N
m
r V
••a°'
c
3
D
C
O
Y
e
,.' A Group
Certificate of Compliance
Certificate: 1841082 Master Contract: 173688
Project: 2550432 Date Issued: August 20,2012
Issued to: Power-One,Inc
740 Calle Plano
Camarillo,CA 93012
USA
Attention:Robert White
The products listed below are eligible to bear the CSA
Mark shown with adjacent indicators 'C'and 'US'for
Canada and US or with adjacent indicator 'US'for
US only or without either indicator for Canada only.
IP® BrijA arwaL
+ Issued by: Brij Aggarwal,P.Eng.
C US
PRODUCTS
CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment
CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment
-Certified to U.S.Standards
Utility Interactive Inverter,Models PVI-6000-OUTD-US,PVI-6000-OUTD-US-W and PVI-5000-OUTD-US,
permanently connected.
Notes:
1. All above models in this series may include expansion board with wireless antennae option and will be
identified with model designation including"—Z"suffix at the end.
2. For details related to rating,size,configuration,etc.reference should be made to the CSA
Certification Record,Annex A of the Certificate of Compliance,or the Descriptive Report.
DQD 507 Rev.2012-05-22 Page:1
CS6P-235/240/245/250/255PX
� CanadianSolar
iv, Electrical Data Black-framed
STC .. .•.
""'' tCwP386PXCS8P24oPkrs6P-24035—ass z opxtssp4s pX Temperature Characteristics
Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W
Na`-,C d N Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.IV 30.2V Pmax _0.43%/°C
' i v�/ G g Optimum Operating Current(Imp) 7.90A 8.03A 8.17A 8.30A 8.43A Temperature Coefficient Voc -0.34%/°C
e
Open Circuit Voltage(Voc) 36.9V 37.DV 37.IV 37.2V 37.4V Isc 0.065%/°C
Black-framed C S 6 P Short Circuit Current(Isc) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature q5±2°C
Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85%
o ..tt Operating Temperature -40°c-+ss°c
Performance at Low Irradiance
ZJS�Ze+O/245�250�255PX Maximum System Voltage 1000V(IEC)/600V(UL) Industry leading performance at low irradiation
Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an
Application Classification ClassA irradiance ofrt.:000w/m'to 200w/m'
Next Generation Solar Module Power Tolerance 0_+5W (AM 1.5,25 )
Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and cell temperature 02172.55:
NewEdge,the next generation module designed for multiple Engineeng Drawings
types of mounting systems,offers customers the added NOd ". os6P`23SPXGssl'24oa CSse-24spxcS6p 5Up cs6P pi4
Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185
value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27.4V 27.5V 1
— IIIappearance,auto groundingand theft resistance. Open Circuit (Voc) (Imp) 33.9V 34.OV 34.1V 34.2V 34.4V I1111111111111111111111I
Optimum0 Operating Current6.27A 6.38A 6.49A 6.60A 6.71A
1111 i "� The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A L.IIWL�IIL.IIWI.
yIIIIIIIIIIIIIIIIII1IIIIII
incorporating the groundbreaking Zep compatible frame. Under Normal Operating Cell Temperature,Irradiance of aoo w/m',spectrum AM 1.5,ambient temperature 2oC,
The specially designed frame allows for rail-free fast wind speed i m/s111111111111111111111111
installation with the industry's most reliable grounding Mechanical Data IIIIIIl,,h'IIIIIII'I,I'IIIIIIIi'
system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156(156)m,2 or 3 Busbars IVI�IIII��
Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60 6 x 10 ',,I 1111
with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) IIIIIIIIIIIIIIIlII11111I1
• Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 Ibs) 111111111111111111111114
reduces installation time quality aesthetic module with lowest system cost. Front cover 3.2mm Tempered glass IIIII111111111I11IIJ11
Frame Material Anodized aluminium alloy k�I"'�I1lhJI 1111
' • Lower system costs - can cut rooftop Best Quality J-BOX IP65,3 diodes lul W",I
installation costs in half
• 235 quality control points in module production Cable 4me(IEC)/12AWG(UL),1000mm
• Aesthetic seamless appearance - low profile • EL screening to eliminate product defects Connectors MC4 or MC4 Comparable
Current Standard Packaging(Modules per Pallet)
with auto leveling and alignment •
AccreditedlSalt misto tres resisprove tant performance Module Pieces er container(40 ft.Container) 672pcs(40'HQ) del
I
o
• p
• Built-in hyper-bonded grounding system - if it's
mounted,it's grounded Best Warranty Insurance 1-V Curves(CS6P-255PX)
j
• Theft resistant hardware • 25 years worldwide coverage
• 100%warranty term coverage SectionA-A j
• Ultra-low parts count - 3parts for the mounting
• Providing third party bankruptcy rights 350
and grounding system • Non-cancellable f
•• Industry first comprehensive warranty insurance by Immediate coverage 1
AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies
world
Comprehensive Certificates — ,20
• Industry leading plus only power tolerance:0-+5W
• IEC 61215,IEC 61730, IEC61701 ED2,UL1703, — — 15
11111MMIIM■
• Backward compatibility with all standard rooftop and CEC Listed,CE and MCS
ground mounting systems • ISO9001:2008:Quality Management System
• ISO/TS16949:2009:The automotive quality *Specifications included in this datasheet are subject to change without prior notice.
• Backed By Our New 10/25 Linear Power Warranty management system
Plus our added 25 year insurance coverage • ISO14001:2004:Standards for Environmental About Canadian Solar
management system
100% Canadian Solar Inc. is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was
97% Added Val • QC080000 HSPM:The Certification for companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in
ao% Ue From Warr Hazardous Substances Reygulations
manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing
g'ur ll= =it='"''li'"" =' : • OHSAS 18001:2007 International standards for solar systems, Canadian Solar delivers solar
power capacity of 2.05GW and cell manufacturing capacity of 1.3GW.
aox -�` °�" - products of uncompromising quality to worldwide
0% _.,,,,,,, .. 1a "2. ;?t ,,,„, 1 ;_r.:: . .r.W ,; occupationalhealth and safety customers. Canadian Solar's world class team of
5 10 15 20 25 • REACH Compliance professionals works closely with our customers to
provide them with solutions for all their solar needs. Headquarters 1545 SpeedvaleAvenue West
f"� p�+ Guelph i Ontario N1K 1E61 Canada
•10 year product warranty on materials and workmanship a �E P.. ^p.♦t �/LL g e c s Tel +1 519 837 1881
•25 year linear power output warranty O �U5`` ,,,, V�sia Fax +, 519 83 2550
• www.canadiansolar.com inquire.cadcanadiansolar.com
www.canadiansolar.corn
EN-Rev 10.17 Copyright 0 2012 Canadian Solar inc.