Plans PITCH: 22 ARRAY PITCH:22 MP1 AZIMUTH:234 ARRAY AZIMUTH:234 MATERIAL:Comp Shingle STORY: 2 Stories PITCH: 22 ARRAY PITCH:22 MP2 AZIMUTH: 144 ARRAY AZIMUTH: 144 MATERIAL:Comp Shingle STORY: 2 Stories 0 0 0 0 J ca ,'—\ Il0I /---"N I I /�--\ I - ; Inv ; % M i' 1\ D D ; ; ° I I �_� 1 ._. 1 I ._. I • 15412 SW 82nd PI 12°Fire Setback p g ET SPACED NO R 4 a, I i :ON CENTER LL LEGEND O 0 0 0 iv IN ANY DtP.ECA N 4:7:iiE ARRAY IS O O " LOCATED VW— fN 3 F-ET 01• A ROOF EDGE, EAVE Oa 'Cry 0 (E) UTILITY METER & WARNING LABEL 0 0 0 0 MP2 . o STSG 'c, 3 INVERTER W/ INTEGRATED DC DISCO 0 0 0— ® INVERTER WARNING LABELS B A vo A DC DISCONNECT & WARNING LABELS \ AC PV3 PV3 Q____ o Q 0 0 AC DISCONNECT & WARNING LABELS 0 Front Of House 0 DC JUNCTION/COMBINER BOX & LABELS OD DISTRIBUTION PANEL & LABELS TOTAL ARRAY AREA (SF): 230 L0 LOAD CENTER & WARNING LABELS TOTAL ROOF AREA (SF): 1950 M O DEDICATED PV SYSTEM METER TOTAL ARRAY AREA IS a 12 PERCENT OF TOTAL ROOF AREA • CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR pm a _ GATE/FENCE an It J INTERIOR EQUIPMENT C) L-= '_i SITE PLAN N Scale: 1/8" = 1' 0 1' 8' 16' �� F CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9721788 0 0 POSE OWNER: DESCRIPTION: DESS_ ■ CONTAINED SHALL NOT BE USED FOR THE STUTEVOSS, DALE W STUTEVOSS RESIDENCE Aaron Banks BENEFIT OF ANYONE EXCEPTS VA-10 E INC., MOUNTING SYSTEM: _, `SO'��CIt e NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15412 SW 82ND PL 3.25 KW PV Arrayy PART TO OTHERS OUTSIDE THE REgPIENTS �.' ORGANIZATION, EXCEPT IN CONNECTION WITH M(OULEs TIGARD, OR 97224 NEay SALE AND USE OF THE RESPECTIVE (13) TRINA SOLAR # TSM-250PA05.18 SOLARCITY WITHOUT THE WRITTEN Z PAGE NAME 3055 Mateo,CAW W0 PERMISSION OF EQUIPMENT, TY INC. RIs ' SOJ6242O38 SHEET: REV: DAIS San CA 94402 POWER-ONE # AURORA PVI-3.0-OUTD-S-US SITE PLAN PV 2 12/21/2013 T:(650)638-1028F:(650)638-1029 (888)-SOL-qTY(765-2489)www.solarclty.com Tilt 'I' I Itr (E) 2x6 ® I� el Nir/ r (E) 2x4 '. 4179iillill " 1 p13'-1'' - ii -5" (E) LBW (E) LBW M A SIDE VIEW OF MP1 RAFTER: (E) 2x8 © 24" o.C. SIDE VIEW OF MP2 RAFTER: (E) 2x8 ® 24" O.C. NTS CEILING JOIST: (E) 2x10 CO 24" O.C. B NTS CEILING JOIST: (E) 2x10 ® 24" O.C. RIDGE: (E) 2x12 RIDGE BOARD RIDGE: (E) 2x12 RIDGE BOARD STRUCTURE MEETS THE MAX SPAN: 13'-1" STRUCTURE MEETS THE PRESCRIPTIVE REQUIREMENTS MAX LANDSCAPE STANDOFF X-SPACING: 72" O.C. (STAGGERED) PRESCRIPTIVE REQUIREMENTS MAX SPAN: 9'-5" OF THE OSISC SECTION 305.4 OF THE OSISC SECTION 305.4 MAX LANDSCAPE STANDOFF X-SPACING: 72" O.C. (STAGGERED) RAFTERS ARE DF#1 RAFTERS ARE DF#1 PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. - SEAL PILOT WITH I (4) (2) POLYURETHANEOLE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C �AT�� �_ (3) INSERT FLASHING. mss-.: .ari .1:- (E) COMP. SHINGLE v�sI�i i i (\) PLACE MOUNT. (E) ROOF DECKING Winil (5l INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6)I BOLT & WASHERS. (E) RAFTER S 1 STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9721788 00 PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE STUTEVOSS, DALE W STUTEVOSS RESIDENCE Aaron Banks � ?, ■ BENEFIT OF ANYONE EXCEPT IN ITY INC., MOUNTING SYSTEM: PIA SOIarCIt y NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15412 SW 82ND PL PART TO OTHERS OUTSIDE THE CONNECTION 3.25 KW PV Array a ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: TIGARD, OR 97224 • THE SALE AND USE OF THE RESPECTIVE (13) TRINA SOLAR # TSM-250PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN I(13)R: PAGE NAME q80 Way PERMISSION OF SOLARCITY INC. 5036242038 SHEET: REV: DATE Son Mateo,CA 94402 POWER-ONE # AURORA PVI-3.0-OUTD-S-US STRUCTURAL VIEWS PV 3 12/21/2013 T:(sso)638-1028 F:(650)638-1029 (88B ra-ry(7s5-2489)0)6.str19.c.com UPLIFT CALCULATIONS *IN �# 1221.2013 *& SleekMount�"' PV System Version 817.6 SolarCity Structural Design Application Ptvdecit iinfotingtines Risk Category: II PV SYstele TYPe Softy owd'" Comp Roof Number of Layers Comp Roof 1 Roof Slope 22° Rafter' ' 24*C).0 PV System Module Orientation Landscape PV Module Area 229 sf PV Module Width 39" PV Module Ln 65" Standoff(Attadiment Hardware) Comp Mount Type C eminidinnof Snow-Loads Ground Snow Load pg 25.0 psf ASCE Table 7-1 Surrounifing Roof Snow 100% 25.0 psf 'ASCE Egg 7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method y/FiAly Enclosed Method Expo Category d Speed V 95 C mph Oy/FiARoof 6.5.6.3 Mom Roof Height h 251t 'Fg.Section 614A/B Sedan 6.2 Effective Wind Area(1 Module) A 17.6 sf I8C 1509.7.1 Wind*eosins Calculation Ctonifidinets Wind Pressure E�re Kz 0.95 Table 6-3 Topowaritic Kzt 1.80 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I; 1.0 Tthle 6-1 Velocity Pressure qh qh=0.00256(Kz)(iCzt)(14d)(V^2){I) Equation 6-15 18.6 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-11B/C/D-14A/B Ext.Pressue Coefficient(Down) GCp(Down) 0.45 rIg.6.119JCID-14A/B Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure tho p(1i ) -16.3 pat Wind Pressure Down p(down) 10.0 psf /010V$4110. X-Olr a Y-Dbectlun Max Max All72" 39" owable Standoff n Spadng Landscape24' NA Standoff Configuration Landscape Staggered Max Standoff Trentary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind UplUt at Standoff T-o -285 lbs Uplift Carty of Standoff T-allow 637 lbs Standoff Dernancgtapactv OCR 44.7% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9721788 O O PREMISE OWNER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE STUTEVOSS, DALE W STUTEVOSS RESIDENCE Aaron Banks moi`!, ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: II rSOIarClty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Com Mount Type C 15412 SW 82ND PL ;.,a PART TO OTHERS OUTSIDE THE REaPIENTS P 3.25 KW PV Array ORGANIZATION, EXCEPT IN CONNECTION WITH MODULESTIGARD, OR 97224 THE SALE AND USE OF THE RESPECTIVE (13) TRINA SOLAR # TSM-250PA05.18 3055 Cleow Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PAGE NAME SHEET: RIRD: DATE Sr Mateoteo,,C CA 9440440 2 PERMISSION OF SOLARGTY INC. POWER—ONE # AURORA PVI-3.0—OUTD—S—US 5036242038 UPLIFT CALCULATIONS PV 4 12/21/2013 T:(650)638-1028 F:(650)638-1029 (889)-SOL-CITY(765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO (E) UFER AT PANEL Panel Number:Cutler—Hammer Inv 1: DC Ungrounded POWER—ONE # AURORA PVI-3.0—OUTD—S—US LABEL: A —(13)TRINA SOLAR ## TSM-250PA05.18 OR # 180498 WITH IRREVERSIBLE CRIMP Meter Number:24 579 827 Inverter; Zigbee, 3000W, 240V, 96% PV Module;INV 1 —(1) SOW, 227.5W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 INV 2 Voc: 37.6 Vpmox: 30.3 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 200A MAIN SERVICE PANEL (E) 125A Distribution Panel E 200/2P MAIN CIRCUIT BREAKER ADJUST MIN. ACTIVATION VOLTAGES! (E) WIRING A 1(E) LOADS COOPER Inverter 1 IND 200A/2P G "--", Meter Socket O �� (� POWER—ONE /` SET M N.ACTIVATION VOLTAGE TO 130V �� �� (E) LOADS AURORA PVI-3.0—OUTD—S—US DC+ • LOADS /� 20A/2P B DC- 1 String(5)Of 6 On MP 2 --=.4(. 4: .— 18 LZ I I.O. —� GFP/GFCI •� DC+ I 60A/2P I NEUT N Z� DC- I 2 DJ 1�7 / _ t1� A I J - GND F- --d-- -'1 GND EGC/ - �� Dc+ (I DC+ SET M N.ACTIVATION VOLTAGE TO 153V r/ •��S i — GEC a �� DG J —DC- DC- 1 I 1 String(5)Of 7 On MP 1 I GND I———-EGC——— ---f-- --— EGC J — V N _ J EGC/GEC 1 Z Z C7 GEC TO 120/240V I SINGLE PHASE UTILITY SERVICE I I II — 1 I 1 —L Voc* = MAX VOC AT MIN TEMP A —(1)CUTLER—HAMM #BR220 PV BACKFEED BREAKER /f►C DC Breaker, 20A/2P, 2 Spaces B —(i)COOPER 125A, 4—i144AAWG Ring Type —(1)AW CAP; B—Line Meter Socket Accessory —(1)MILBANK M CL200 Meter; FORM 2S I (1)AWG 0, THWN-2, Black —(1)AWG#10, THWN-2, Black ®I`"-(1)AWG#6, THWN-2, White 3 —(2)AWG)AWG#10, PV HARE, Black Voc* =253.03VDC Isc =8.85 ADC —(1)AWG#10, THWN-2, Red (1)AWG#4, THWN-2, Green EGC Vmp =240 VAC Imp=14.5 AAC f (1)AWG#10, THIN-2, White NEUTRAL Vmp =240 VAC Imp=14.5 AAC O —(1)AWG/8 Solid Bare Copper EGC Vmp =181.8 VDC Imp=8.27 ADC —(1)Conduit Kit; 3/4'EMT —(1)AWG#6, THWN-2,Green EGC/GEC—(1)Conduit Kit; 3/4'EMT (1)Conduit Kit; 3/4' EMT 0—(2)AWG#10, PV VWRE,Black Voc* =295.21 VDC Isc =8.85 ADC 'g—(1)AWG#8,Solid Bare Copper EGC Vmp =212.1 VDC Imp=8.27 ADC (1)Conduit Kit; 3/4'EMT CONFIDENTIAL— THE INFORMATION HEREIN ADB NUMBER: J B-9721 788 00 PREMISE OWER: DESCRIP11ON; DESIGN: CONTAINEDFIT SHALL NOT BE USED FOR THE STUTEVOSS, DALE W STUTEVOSS RESIDENCE Aaron Banks moi`!, ONEST OF ANYONE EXCEPT SOLARCITYFOR1 INC., MOUNTING SYSTEM: .,,SolarCity NOR SHALL IT BE DISCLOSED IN WdOLE OR IN Comp Mount Type C 15412 SW 82ND PL �1 PART TO OTHERS OUTSIDE THE RECIPIENTS 3.25 KW PV Array ORGANIZATION, EXCEPT IN CONNECTION VATH /ADES TIGARD, OR 97224 DUC THE SALE AND USE OF NE RESPECTIVE (13) TRINA SOLAR # TSM-250PA05.18 3055 Cleadew Way SOLARCITY EQUIPMENT, WITHOUT THE V.RITTEN INVERTER: PAGE NAMESHEET: REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. POWER—ONE # AURORA PVI-3.0—oUTD-S—US 5036242038 THREE LINE DIAGRAM PV 5 12/21/2013 T:(650)638-1028 F:(650)638-1029 (886)-SOL-aw(765-2489)www.solarcity.can Label Location: Label Location: Label Location: CAUTION SOLAR CIRCUIT (C) MAXIMUM AC A (AC)(P01) CAUTION (P01) • Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: CA Fire Guidelines MAXIMUM AC _ NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC)(P01) WARNING (DC) (INV) DISCONNECT FOR Per Code: Label Location: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35 F THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER-- (DC)(INV) PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN UNGROUNPOINT CURRENT(Imp) A Per Code: MAY BE ENDERGIZED INVERTER IS MAXIMUM POWER-_V NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEMd Label Location: VOLTAGE(Voc)_' WARNING (AC)(POI) SHORT-CIRCUIT A Per Code: CURRENT(Iso) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC)(CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION NEC 690.64.8.7 ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5 C WARNING: ELECTRIC SHOCK IF A GROUND FAULT IS INDICATED ( ) HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A PHOTOVOLTAIC AC (AC)(P01) OPERATING CURRENT AC):AC Disconnect MAXIMUM AC (C): Conduit DISCONNECT Per Code: OPERATING VOLTAGE _ V NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit CAUTION (D)(POI) (INV): Inverter With Integrated DC Disconnect Per Code: (LC): Load Center PHOTOVOLTAIC SYSTEMNEC 690.64.8.4 (M): Utility Meter CIRCUIT IS BACKFED (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR NE BENEFIT OF ANYONE EXCEPT SOLARGTY INC., NOR SHALL IT BE DISCLOSED =Oi t•4 3055 Cleaview Way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set • San Mateo,CA 94402 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE �„ Solar( ityT:(65o)638-1028 F:(650)638-1029 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (888)-SOL-CIT'(765-2489)www.solarcity.com • 0 ZS Comp Edge Zone Calculations 1 of 4 i ZS Comp Edge Zone Calculations 2 of 4 Zep Solar 5/28/13 Zep Sola r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations General Design Information: All variable the same as above except for roof pitch Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 Comp Mount Allowable Loads GCN portrait= 0.4 0.9 0.9 Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs ' tubi!, note:use 10 psf minimum ir ;-.74 ice- Snow Calculations Attachment Spacing Calculations 85818 To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing a OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load e` '0. I.P above 30 degrees. uplift spacing= f.trr Roc,- module ocmodule length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 p=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 K,K, Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph xposure= C Roof Zone= Edge Zone Down Force Load Roof Pitch Importance Factor= 1.0 K,= 0.98 from Table 6-3 Combinations: 14 30 Gable Hi Roof D+S= 31.16 25.10 psf Gable/Hip K,= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 :;32.46psf Roof Height= 30 GCN landscape= -1.6 lscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape downforce spacing= 11471bs in ortrait effective area= 21.7 ft2 p p g 39"x 32.46psf x 144 ft2 = 130" Plandscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing= 65"x 32.46psf x 144 ft2 = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs landscape uplift spacing = 39"x 29.05 psf x 144 landscape =83" 656 bs portrait uplift spacing = 65"x 27112 psf x 144 ft2 =54" • 0 ZS Comp Edge Zone Calculations 3 of 40 ZS Comp Edge Zone Calculations 4 of 4 ZepSotar 5/28/13 ZepSotar 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing p g=-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273=73" ps=C5 Pf Roof Pitch= 31 45 degrees pf=0.7 Ce Ct l pg Ce= 0.9 C5= 0.71 0.45 Ct= 1.2 pf= 22.68 22.7 psf portrait module spacing=-1.7917 x 32.46 psf+118.58=60" I= 1.0 ps= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30° 27" 30" Lateral 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing= 39"x 14.49 psf x 144 ft-z =74" 292lbs in portrait lateral spacing= 65"x 14.49 psf x 144 ftz =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing= 65"x 13.50 psf x 144 ft2 =48" • SolarCity SleekMountTM - CompSolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and •Interlock and grounding devices in system UL 1 • Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps,combined with the addition of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 �- Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" 40 Insert Comp Mount flashing under upper utilizes Zep Compatible"' modules with •Ground Zep UL and ETL listed to UL 467 as '� layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs,effectively eliminating the +. Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing Standoffs required. In addition, composition •Anodized components for corrosion resistance I \ Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this ,,._: with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions \111Ihh_. a) Secure Leveling Foot to the Comp Mount using machine Screw 4) Place module 4 • Components oilicroi. 0 ,_ i 5/16"Machine Screw , 0 L: ::0ot 4. L ® i Comp Mount le - a Comp Mount Flashing /moo' 0 ,r,vi 40. �i �pMPATje ,"/I SolarCity -„ Solareity January 2013 kV,: �I. LISTED �: ` oOMPP� ® January 2013 3, wo - W .. k R' O 0 R° O 0 � o 0 Na N Y CL 3 n CL a a ;ea '^ °a 3 e 2 o ;3� pa a c xc°01c Q N S O _ O 3 x 0 > yam'. a n A c A 7. k o 3 c O N n x �m A F d N v❑ c S H O P N O S � 00 w ._ e y '" t0 d N A 7 d A O 3 L1 d O Q xa�T o D d 3 iA v oo - S n% 3 % N �. »O G Rp<_ N S O _ O ado 0 > yam'. a n A c A 7. k 3 d k c O N n O o O F d N v❑ c S I O P N O S � 00 w O 3 L1 ap V O v O D d MUI o S t p� r N O N P A V N Oo P O A A H Ib1 � � S C 3 A 0 c, O � � d iu 3 RIM R"E KIT �Rm , N d � qllii N V1 v O N = � d A 0 p G D N � n o 3 l S d N S O _ O 0 C N O o A pp N jMIH � k 3 d k c O N n O o O F d N v❑ c S I O P N O S � 00 w O 3 L1 ap V O v O D A p N o S t p� O In O Q O k 0 C O � N CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. ® RodY-Hovnpstuck Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment for Use With Distributed Energy Resources(January 28,2010) DQD 507 Rev.2009-09-01 Page.1 C TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05,18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 941mm Peak Power Watts-Pvmx(Wp) 240 245 250 255 260 Power Output Tolerance-Pew(%) 0/+3 0/+3 0/+3 0/+3 0/+3 ,uNaion o Maximum Power Voltage-V.•(V) 29.7 30.2 30.3 30.5 30.7 BOX TS PAOMaximum Power Current (A) 8.10 8.13 8.27 8.36 8.47 (V)NAh1EPUrE� � Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 . INSTnwnG„oEE `„' Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rim(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m'according to EN 60904-1. E O p m 3 3 ELECTRICAL DATA W NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 O i - PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 L Maximum Power-PMAx(Wp) 174 178 181 184 188 Maximum Power Voltage-V.,.(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE • 6-04.3GROUNDING HOLE • Maximum Power Current-I PP(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME4%...44444441, oAA,N„a E AA Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 _' Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 240 `6 O W 812mm 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. ` Back View POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA a) • Compatible with all major BOS components and system - " Solar cells Multicrystalline 156 x 156 mm(6 inches) designs Cell orientation 60 cells(6 10) 15.9% a Module dimensions 1650.992 x 40 mm(64.95 x 39.05 x 1.57 inches) Weight 18.6 kg(41.0 Ibs) MAXIMUM EFFICIENCY Lill Glass High transparency solar glass 3.2 mm(0.13 inches) //� One of the industry's most trusted modules Backsheet White w ,'��!� • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with Trinamount Groove O I1 ( • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 i-Box IP 65 or IP 67 rated v Q Cables Photovoltaic Technology cable 4.0 mm°(0.006 inches'), POWER OUTPUT GUARANTEE 10.. 1100 mm(43.3 inches) 9.-1000WFm' -- _. .. ._ _ 8.m 800w/m' - - Connector Original MC4 Highly reliable due to stringent quality control 6m 600W/m' As a leadingglobal manufacturer m s m 9 • Over 30 in-house tests(UV,TC,HF,and many more) U 4.00- ow/m'- \ -- TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic 1 - • In-house testing goes well beyong certification requirements am products,we believe close 200W/m2__ _ Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C 2m �� cooperation with our partners I v \ Temperature(NOCT) Maximum System 1000V DC(ICC)/ 0.IS critical to success. With local presence around the globe,Trina is m Temperature Coefficient of PMAx -0.43%/°C Voltage 600V DC(UL) o.� lo.m 20� 30� 4om g able to provide exceptional service Voltage(V) Temperature Coefficient of Voc -0.32%/°C Max Series Fuse Rating 15A to each customer in each market Temperature Coefficient of Inc0.047%/°C and supplement our innovative, ertified to withstand challenging environmental - reliable products with the backing conditions I of Trina as a strong,bankable VW • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module(5400 Pa) to building strategic,mutually 0 year Product Workmanship Warranty beneficial collaboration with installers,developers,distributors 25 year Linear Power Warranty and other partners as the (Please refer to product warranty fordetailsl backbone of our shared success in CERTIFICATION driving Smart Energy Together. UNEAR PERFORMANCE WARRANTY °O� !�• PACKAGING CONFIGURATIONpieces j 10 Year Product Warranty•25 Year Linear Power Warranty /\�' V Trine Solar Limited "" \ W, as Modules per box:24 pieces www.trinasolaccom 8100% - A ,�.t Modules per 40'container:672 pieces f Adarhonol ISO i (E COUS vv lrcLctso i C E COUS vv-lrc� I ao Value Bohr Tilhq rmeo V m 90% m $ • a "' �'„ .� .' f . olOYs linear N'orrghl CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. 010'474 C '"[` Trinasolar ®2013 Trina Solar Limited.All rights reserved.Specifications included in this dotosheet are subject to N¢ / �, Trinasolar O 80% � s y change without notice. ... . ..:E& >4. .t 'ES i�. nsc.»eta,.. iM.�.€�... E'>'���,, Smart Energy Together reo s l0 15 20 25 Smart Energy Together Om �_, Trinasolar °nHp�w�