Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (38)
TOTAL ROOF AREA (SF): 2606 °° PITCH: 18 ARRAY PITCH:18 17O 41 I I°At MP1 AZIMUTH: 184 ARRAY AZIMUTH: 184 TOTAL, ARRAY AREA (SF): 701 MATERIAL:Comp Shingle STORY: 1 Story U■ TOTAL ROOF COVERAGE: 26.9% s° .. .4 ., 11 Ifir •° ,,,,...- f--„,-;:,0*-,,,,..,,4-",.,-, . 4'— ;::: '-',r4A'C'':;C...1E,I');293 . 440 4 ,, „„A. L,-,-„ ,...,,,,„ ‘,-,,,, ' $ c, " S 6�laJ'Ji 0 : iiiirV *Or .: 0.0 Front Of House LEGEND Q (E) UTILITY METER & WARNING LABEL INVERTER W/ _ __ -- _ _— "'setback __ ❑ ❑ OI --a---a- J o ® & WARNING LABELS DC DISCO r — 0 0 0 I 0 0 0 00 0 0 —' ® DC DISCONNECT & WARNING LABELS -o 0 0 AC 0 0 0 0 0 0 0 3 p9 AC DISCONNECT & WARNING LABELS c O O O O L_ 12"Fre Setback (E) DRIVEWAY 2 D 0 0 0 0 DC JUNCTION/COMBINER BOX & LABELS Ji I "—i I C/) L- ---a LL 0 e 0 0 0 0 --v-- 0 0 '"7 0 DISTRIBUTION PANEL & LABELS in Inv , - r--) 0 0 0 P o 0 `_ _-o o o Lc LOAD CENTER & WARNING LABELS K 0 0 0 0 0 0 'c O DEDICATED PV SYSTEM METER 0 O a`I 'MP1 0 e o ' CONDUIT RUN ON EXTERIOR 1011111/11* �_ I CONDUIT RUN ON INTERIOR AC GATE/FENCE .1.111,4Aki� A © °c t ^' INTERIOR E`i , PV30 L QU PMENT � �, ��,kAW4 SITE PLAN N ',' , an o, Scale: 1/8" = 1' Ilk ', . °o W E -' , 01' 8' 16' `� CONFIDENTIAL- THE INFORMATION HEREIN ,IDB NUMBER JB-9721823 0 0 PREMISE ONMER: DE�'1QN' DESIGN: CONTAINED SHALL NOEXCEPTT BE USED FOR THE BROOKS, MARK BROOKS RESIDENCE Jarret Childers � �, ■ NOL IT BE DISCLOSED IN WHOLERINC., Comp SYSTEM: 11353 SW IRONWOOD LOOP .4SolarCit . NOR SHALL IT BEOUTSIET E RECIPIENT'S OR IN Comp Mount Type C with Lifter 9.75 KW PV Array ���� PART TOIZ OTHERSON, OUTSIDE THE ECTION WITH TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTrvE (39) TRINA SOLAR # TSM-250PA05.18 3055 clew►,way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN IN�RTER PAGE NAME: SHEET: REV DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. FRONIUS # IG PLUS V 7.5 5035798515 SITE PLAN PV 2 1/13/2014 T:(650)636-7028 F:(650)638-1029 (688)- 24(765-2489)www.edaraHyoOm (E) 2x4 • \ 0/ e -/ 9'-9" 5'-1" / 9'-5" / 1'-2"+ (E) LBW (E) LBW `- (E) LBW A SIDE VIEW OF MP1 RAFTER: (E) 2x6 0 24" O.C. NTS CEILING JOIST: (E) 2x6 0 16" O.C. RIDGE: (E) 2x6 RIDGE BOARD MAX SPAN: 9'-9" MAX LANDSCAPE STANDOFF X—SPACING: 72" O.C. (STAGGERED) PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS (6) INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP ARRAY SKIRT (1) LOCATION, AND DRILL PILOT fir;-;� 011 ■11 NM.ii � . HOLE. (4) �■�,: (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. II II ZEP FLASHING C (3) (3) INSERT FLASHING. (E) COMP. SHINGLE vii�u■■mimiimr.-- I- (4) PLACE MOUNT. (E) ROOF DECKING :. 1111111111 INSTALL STALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) C BOLT & WASHERS. (E) RAFTER6 STANDOFF Scale: 1 1/2" = 1' CONFIDENTIAL— THE INFORMATION HERON JOB NUMBER: JB-9721823 00 PRB°SE MR: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BROOKS, MARK BROOKS RESIDENCE Jarret Childers +I' ■ BENEFIT LL ITANYONEDI EXCEPT SOLARCITYHLEINC., MOUNTING ompSYSTEM: 11353 SW IRONWOOD LOOP ►,,So�a�C�tj/. NOR SHALL H BES OUTSIDE IN ECOLE CR IN Comp Mount Type C with Lifter 9.75 KW PV Array ��"� PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION H MODULES TIGARD, OR 97223 WIT THE SALE AND USE OF THE RESPECTIVE (39) TRINA SOLAR # TSM-250PA05.18 3055 tea,CAw Way ' SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN ER: PAGE NAME: SHEET: REN DATE SiaMateo, 94402 PERMISSION OF SOLARCITY INC' FRONIUS # IG PLUS V 7.5 5035798515 STRUCTURAL VIEWS PV 3 1/13/2014 1:(650)638-1028 F:(650)636-1029 (888rSOL—CTY(7s5-2489)www.solarcityeam UPLIFT CALCULATIONS • `a°�. 01.13.2014 = SolarCity SleekMountT"' PV System Version#17.6 Structural Design Application Project Information Risk Category: II PV System Type Solaraty SieekMountTM Comp Roof Comp Roof Number of Layers 2 Roof Slope 180 Ratter Spacing 24"0 C PV System Module Orientation Landscape PV Module Area 687 sf PV Module Width 39" PV Module Length 65" Standoff(Attachment Hardware) Comp Mount Type C with Lifter Ground f Roof Snow Loads Ground Snow Load Pg 25.0 psf 'ASCE Table 7-1 Surrounding Roof Snow 100% 25.0 psf 'ASCE Eq:7.4-1 Roof Snow Over PV Modules 100% 25.0 psf 'ASCE Eq:7.4-1 Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C ' Section 6.5.6:3 Roof Style Gable Roof 'Fig.6-118/qo-144/B Mean Roof Height h 15 It Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Prosanarte Calculation Cool icient8 Wind Pressure Exposure Kz 0.85 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh=0.00256(Kz)(Kzt)(Kd)(VA2)(I) 16.7 psf Equation 6-15 Ext.Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D-14/0 Ext Pressure Coefficient(Down) GCp(Down) 0A5 Fig.6-11hW/c7o-i4a/a Design Wind Pressure p p=qh(GCp) Equation 6-22 Wind Pressure Up POW -14.6 psf Wind Pressure Down p(down) 10.0 psf Allowable Standoff Spacings X Direttlon Y-mon Max Allowable Standoff Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max StandaffTribultary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Standoff Ti-actual -252 lbs Uplift Capacity of Standoff T-allow 637 lbs Standoff Dernand/Capacity DCR 39.5% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9721823 O O PREMISE OMMER: DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE BROOKS, MARK - BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: BROOKS RESIDENCE Jarret Childers `,_„=s • NOR SHALL IT BE DISCLOSED IN WHOLE OR IN .,,So�arCity. CompMount Type C with Lifter 11353 SW IRONWOOD LOOPArray �.,,s PART TO OTHERS OUTSIDE THE RECIPIENTS ' TIGARD, OR 97223 9.75 KW PV ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (39) TRINA SOLAR # TSM-250PA05.18 3055 CleaCA 440 Woy - SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY IY INC ' PAGE NAME SHEET: REV DALE San Mateo,CA 94402 FRONIUS # IG PLUS V 7.5 5035798515 UPLIFT CALCULATIONS PV 4 1/13/2014 (888)—SOL—CITY(1065-2489) �Tdtycem GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO TWO (N) GROUND Panel Number:LC612PS Inv 1: DC Negatively Grounded INV 1 —(1 )FRONIUS # IG PLUS V 7.5 LABEL: A —(i9)TRINA SOLAR_# OR 180498 RODS AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:24 539 477 Inverter; 7500W, 277V/240V/208V, 96%/95.5%/95% PV Module; 0W, 227.5W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 ` INV 2 Voc: 37.6 Vpmax: 30.3 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E) 200A MAIN SERVICE PANEL Multiple Main Breakers (6 or fewer) (E) WIRING Inverter 1 CUTLER-HAMMER COOPER STRINGS TO BE COMBINED 0 INVERTER. Disconnect Meter Socket `LJ FRONIUS FUSING REQUIRED INSIDE INVERTER. (E) LOADS A B IG PLUS V 7.5 (1 ' --�C Dc+ --•�R. - L, 240V l , l I i .�.--_ L2 --- ��� i� �, t GFP/GFCI f DC+ I 40A/2P N { /1� DC- 3 String(s)Of 13 On MP 1 /i, u n �� I o A i V———— GNDl— —— 1 GND}- GEC - ��♦DC+ LJ—-- DC. O G-- —. O B I \ L---�D ------ i DG 1 GND I____EGC_-- — EGC , U N — J EGC/GEC Z—Z C.2 T GEC r 1 TO 120/240V I I SINGLE PHASE I I UTILITY SERVICE ICE I I I I I 1 I I I I I _i.._J— VOC* = MAX VOC AT MIN TEMP POI—(1 )CUTLER—H 40A 2 ,B 0 PV BACKFEED BREAKER A —0 )CUTLER—HAMMER /DG222URB w D Breaker, 40A 2P, 2 aces Disconnect; 60A, 24OVac, Non—Fusible, NEMA 3R H ^ —(2)Ground Rod; 5/8'x 8',Copper —(1 )CUTLER—HAMMER_/DG100NB (v Ground/Neutra it; 60-100A, General Duty(DG) B (1 )COOPER Socket; 125A,,t4-14AY Ring Type —(1 )AW CAP; B—Line Meter Socket Accessory —(1 )MlILBANK L'CL200 Meter; FORM 2S O Black —(1 )AWG/8, THWN-2,Bla--(1 )AWG#8, THWN-2, Red (6)AWG/10, USE-2/RHW-2,Black Voc* =548.24VDC Isc =8.85 ADC (1 )AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=31.3 MC O (1 )AWG/6, Stranded Bore Copper EGC Vmp =393.9 VDC Imp=8.27 ADC —(1 )AWG 06, THWN-2, Green EGC/GEC—(1 )Conduit Kit; 3/4'EMT (1)Conduit Kit; 1'EMT CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER JB-9721823 0 0 PREISSE OW: DESCRIPTION: DESIGN: • CONTAINED SHALL NOT BE USED FOR THE BROOKS, MARK BROOKS RESIDENCE Jarret Childers � t, BENEFIT OF ITANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 11353 SW IRONWOOD LOOP SolarCityPAR STALL H BE DISCLOEED IN WHOLE OR INComp Mount Type C with Lifter 9.75 KW PV ArrayPART TO OTHERS OUTSIDE THE REPIENI'S TIGARD, OR 97223 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: THE SALE AND USE OF THE RESPECTIVE (39) TRINA SOLAR # TSM-250PA05.18 3055 Clearview Way SOLAROTY EQUIPMENT, WITHOUT THE WRITTEN INVERTER PAGE NAME SHEET: REV DATE San Mateo,CA 94402 PERMISSION OF soLARgrr INC. FRONIUS # IC PLUS V 7.5 5035798515 THREE LINE DIAGRAM PV 5 1 13 2014 T:(650)638-1028 F:(650)638-1029 (888)—SOL—CITY(765-2489)www.sdarcftycan Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C)(IC)(CB) MAXIMUM AC _ A (AC) (P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: IFC 605.11.1.4 MAXIMUM AC NEC 690.54 SECOND SOURCE IS OPERATING VOLTAGE V PHOTOVOLTAIC SYSTEM NEC 690.64.8.4 Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC) WARNING (DC)(INV) DISCONNECT FOR Per Code: Label Location: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35 F THE DC CONDUCTORS OF THIS ( ) MAXIMUM POWER-- (DC)(INV) PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT CURRENT(Imp) A Per Code: UNGROUNDED AND INVERTER IS MAY BE ENERGIZED MAXIMUM POWER-_v NEC 690.53 UNGROUNDED POINT VOLTAGE(Vmp) MAXIMUM SYSTEM_V Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT A Per Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) ELECTRICAL SHOCK HAZARD Per Code: DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (POI) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION NEC 690.64.8.7 ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5 C WARNING: ELECTRIC SHOCK IFA GROUND FAULT IS INDICATED ( ) HAZARD. DO NOT TOUCH NEC 690.17.4; NEC 690.54 NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT PHOTOVOLTAIC AC (AC) (P01) MAXIMUM AC (AC): AC Disconnect DISCONNECT Per Code: OPERATING VOLTAGE _ V (C): Conduit NEC 690.14.C.2 (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect Label Location: (IC): Interior Run Conduit CAUTION (D) (P01) (INV): InverterLoad WithCenter Integrated DC Disconnect PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED =*„�i 3055 Cleaview Way IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - OR Label Set ■ San Mateo,CA 94402 EXCEPT IN CONNECTION VWTH THE SALE AND USE OF THE N RESPECTIVE ��' S��arC�ty T:(eso)638-iozs F:(650)638-1029 SOLARCITY EQUIPMENT, WITHWT THE WRITTEN PERMISSION OF SGLARCITY INC. (888)-SOL0)638Mateo, :(9)94402www. rcity.com 0 ZS Comp Edge Zone Calculations 1 of 40 ZS Comp Edge Zone Calculations 2 of 4 ZepSotar 5/28/13 Ze p J Q t a 5/28/13 . This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations General Design Information: All variable the same as above except for roof pitch Module Size: 39"x 65" Roof Pitch Basic Wind Speed= 95 mph System Weight= 3 psf Ground Snow Load= 30 psf 14 30 45 GCN landscape= 0.5 0.9 0.9 Comp Mount Allowable Loads GCN portrait= 0.4 0.9 0.9 Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs Ro. 1111:1011 note:use 10 psf minimum Ir • "4*.tilW Snow Calculations Attachment Spacing Calculations 85818 �� To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing /3 OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load "F�9 m. �c� above 30 degrees. uplift spacing= '4-my ROC module length or width x design load EXPIRES: 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 p=qh GCN Design Snow Load 29.11 25.98 psf qh=0.00256 K,K,Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Exposure= C Roof Zone= Edge Zone Down Force Load Roof Pitch Importance Factor= 1.0 K Combinations: 14 30 Z= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof K,= �t- 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= 4.5 landscape down force spacing_ 11471bs in ortrait effective area= 21.7 ftZ p f p g 39"x 32.46psf x 144-tZ = 130" Plandscape= -30.79 psf qh= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 ftZ = 78" Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs in landscape uplift spacing = 39"x 29.05 psf x 144 ftZ =83" portrait uplift spacing = 65"x 27.12 psf x 144 in =54" ZS Comp Edge Zone Calculations 4 of 4 ZS Comp Edge Zone Calculations 3 of 4 hep r ZepSotarSQ lel' 5/28/13 Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing= -1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing= -1.4545 x 32.46 psf+120.7273 =73" Ps=C5 Pf Roof Pitch= 31 45 degrees Pf=0.7CeCflpg Ce= 0.9 C5= 0.71 0.45 C = 1.2 pf= 22.68 22.7 psf portrait module spacing =-1.7917 x 32.46 psf+118.58=60" I= 1.0 p5= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30, 27" 30" Lateral 74" 48" 45" Lateral Force Component Module Deflection 73 60" • Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14'.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing = 39"x 14.49 psf x 144 ftz = 74" 292lbs in portrait lateral spacing= 65"x 14.49 psf x 144 ftz =45" Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = 65"x 13.50 psf x 144 ftz =48" INPUT DATA ` Fronius la Plus V 3.0-1 as I 3.8-1 uM 5.0-1 ax 1 8.0-1 uw 7,5-1 en 10.0-1 uw 11.4-1 w. 11A-3 12.0-3 as Recommended PV-Power(W p) 2500-3450 3200-4400 4250-5750 5100-6900 6350-8600 8500-11500 9700-13100 9700-13100 10200-13800 3<. . - r MPPT-Voltage Range 0 230...500 V - .� DC Startup Voltage 245 V ,,.. -, , _4410,4"; Max.Input Voltage(at 1000 W/m= c 14°F(-10°C)in open circuit operation) 600 V "`_ Nominal Input Current $ P 8.3 A 10.5 A 13.8 A 16.6 A 20.7 A 2Z6 A 31.4 A 31.4 A 33.1 A Max.usable Input Current P 14.0 A 17.8 A 23.4 A 28.1 A 35.1 A 46.7 A 53.3 A 53.3 A 56.1 A Admissible conductor size(DC) No.14-8 AWG - `"Fg Number of DC Input Terminals 6 ka; Max.Current per DC Input Terminal 20 A;Bus bar available for higher input currents OUTPUT DATA fronius IG Plus V 3.0-1 en 3,8-f a 5,0-1,,,r B4O-1,t,. 7.8-1 a, 10.0-1 uM 11,4-1.. 11.4-3 o.r ? 12,0-3 i Nominal output power(P��) 3000 W 3800 W 5000 W 6000 W 7500 W 10000 W 11400 W 11400 W 12000 W a , �' Max.continuous output power 104'F(40"C)208 V/240 V/277 V 3000 W 3800 W 5000 W 6000 W 7500 W 10000 W 11400 W 11400 W 12000 W Nominal AC output voltage 208 V/240 V/277 V "` 208 V/240 V 277 V Operating AC voltage range 208 V 183-229 V(-12/+10%) " (default) 240 V 211-264V(-12/+10%) 277 V ` 244-305 V(-12/+10%) „ _ , .:( , ' • Max.continuous . d , ^' , 208 V 14.4 A 18.3 A 24.0 A 28.8 A 38.1 A 48.1 A 54.8 A 31.6 A' n.a. output current 240 V 12.5 A 15.8 A 20.8 A 25.0 A 31.3 A 41.7 A 47.5 A 27.4 A° n.a. { 277 V 10.8 A 13.7 A 18.1 A 21.7 A 27.1 A 36.1 A 41.2 A n.a. 14.4 A° ', - t -' ,Q Admissible conductor size(AC) No.14-4 AWG xq', :. Max.continuous utility back feed current 0 A ** -;r *,.1% t ' '_ ales t Nominal output frequency 60 Hz Operating frequency range 3 p,', 59.3-60.5 Hz r w tiv Total harmonic distortion <3% Power factor 1 ,t .-.....;,..e.:, 9.. • �' �_ "1,/,‘;, :,:",.'a•-;-_, . ',. , ' ,.. F� ® GENERAL,DATA Fronius la Plusv� 3.0-1 u. ;� ss-1 uM l � s.o-1,,N � r S.o-1,„„ ' 7.5-1 10.0=1 1�s-1 -11.4- ,,. i• ' ( ,..+�' ' uN �... up ux �:. o.w ';12.0-31vrEnr.. GEC Efficiency Max. ciency 3 - 96.2%% ciency 208 V 95 0% _ _ ,�• 95.0% 95.5% 95.5% 95.095.0% 95.0% 95.0% n.a. -° =t 240 V 95.5% 95.5% 95.5% 96.0% 95.5% 95.5% 95.5% 96.0% n.a. 277 V 96.0% 96.0% 98.0% 96.0% 96.0% 96.0% 96.0% n.a. 96.0% Consumption in standby(night) <1.5 W Q Consumption during operation 8 W 14 W 20 W Fro n 1 us IG P'LIS PV I nve rter Cooling Controlled forced ventilation,variable fan speed 3` Enclosure Type NEMA 3R Unit Dimensions(W x H x D) 17.1 x 26.5 x 9.9 in. 17.1 x 38.1 x 9.9 in. 17.1 x 49.7 x 9.9 in. The first complete solution. Reliable. Proven, Smart. I Power Stack Weight 31 lbs.(14 kg) 57 lbs.(28 kg) 82 lbs.(37 kg) 12 / ;.: Wiring Compartment Weight 24 lbs.(11 kg) 26 lbs.(12 kg) 26 lbs.(12 kg) An outstanding addition to the family:The next i ,, Admissible ambient operating temperature 4...122"F(-20...+55°C) generation Fronius IG Plus inverter builds on a Compliance UL 1741-2010,IEEE 1547-2003,IEEE 1547.1,ANSI/IEEE C62.41,FCC Part 15 A&B,NEC Article 690,C22.2 No.107.1-01(Sept.2001) , successful model with multiple enhancements, PROTECTION including maximum power harvest,a built-in six ,,` DEVICES fronius 10 Plus V I 3.0-i�. 3.6-1 ur 8.0-1 uK 6.0-1. 7.5-1 u,a I 10.0-1. I 11.4-1�a 111.4-3 112.0-3 wrrsrr circuit string combiner,integrated,lockable DC = Ground fault protection Internal GFDI(Ground Fault Detector/Interrupter);in accordance with UL 1741-2010 and NEC Art.690 Disconnect,significantly improved efficiency,and - DC reverse polarity protection 4 aInternal diode ? # p Islanding protection Internal;in accordance with UL 1741-2010,IEEE 1547-2003 and NEC unbeatable reliability. New,larger power stages Over temperature Output power derating/active cooling expand the proven Fronius 10 family from 2 to 12 kW in a single inverter. - °per Phase Fi Dfl/LI 1F/'"On%L/5 i. Fronius USA LLC Solar Electronic Division 10421 Citation Drive,Suite 1100,Brighton,Michigan,48116 8 POWERING YOUR FUTURE E-Mail:pv-usOfronius.com S www°fronius-usa.com o SolarCity SleekMountlM - Comp SolarCity SleekMountTM Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules \ • f aesthetics while minimizing roof disruption and labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Drill Pilot Hole of Proper Diameter for mounting clamps, combined with the addition listed to UL 2703 : Fastener Size Per NDS Section 1.1.3.2 of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 '� Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" \,--- Insert Comp Mount flashing under upper utilizes Zep CompatibleTm modules with •Ground Zep UL and ETL listed to UL 467 aslayer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs,effectively eliminating the Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing Standoffs required. In addition, composition •Anodized components for corrosion resistance I \ Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this _ with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions 40 Secure Leveling Foot to the Comp Mount using machine Screw 40 Place module ft c1 Components — 5/16"Machine Screw Leveling Foot , - J Lag Screw * Y 'K: � ,i ® I Comp Mount - f'' Comp Mount Flashing " 7 ^p•' �� >. N1141.0 EP do ,►;vii r .d �oMTiB0.94 j 4, %i + - • ♦rw'f+ Sofa�'ty® January 2013 ., • ( LISTED -comp" ,yrtiSolarCity® January 2013 TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA W STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 ' 941mm Peak Power Watts-Pens(Wp) 240 245 250 255 260 Power Output Tolerance-Pens(%) 0/+3 0/+3 0/+3 0/+3 0/+3 A • HOT'" jo Maximum Power Voltage-Ver.(V) 29.7 30.2 30.3 30.5 30.7 BOX Tsm pA05 , Maximum PowerCurrent-len.(A) 8.107 8.13 3.277.6 8.36 8.47 NAMEPLAT O • �A9x, Open Circuit Voltage-Von(V) 37.3 37.5 37.6 37.7 37.9 'N4AI°Hc"oss 1 8 Short Circuit Current-Isc(A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rim(%) 14.7 15.0 15.3 15.6 15.9 THE IRINAMOUNT MODULE 3 STC:Irradiance 1000 W/m',Cell Temperature 25°C,Air Mass AM1.5 according to EN 60904-3. E Average efficiency reduction of 4.5%at 200 W/m°according to EN 60904-1. E `o 0 3 3 ELECTRICAL DATA @ NOCT TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 60 CELL PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-Pens(Wp) 174 178 181 184 188 MULTICRYSTALLINE MODULE • Maximum Power Voltage-Ver.(V) 26.6 26.8 27.0 27.2 27.4 6.0 4 3 axouNoiNe HOLE A A Maximum Power Current-Iei,p(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME DRAIN HOLE Open Circuit Voltage(V)-Von(V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 240 26 0 W d 812mm I 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed I m/s. Back View POWER OUTPUT RANGE Our most versitile product MECHANICAL DATA 0 • Compatible with all major BOS components and system -I 71 I designs Solar cells Multicrystalline 156°156 mm(6 inches) Cell orientation 60 cells(6 10) 15.9% a Module dimensions 1650 a 992.40 mm(64,95 s 39.05 a 1.57 inches) Weight 18.6 kg(41.0 Ibs) MAXIMUM EFFICIENCY 1 Glass High transparency solar glass 3.2 mm(0.13 inches) One of the industry's most trusted modules Backsheet White Frame /�/�� .•,!% • Over 2 GW sold across all major global markets Black Anodized Aluminium Alloy withTrinamounTGroove 0 +37 • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), POWER OUTPUT GUARANTEE 10°° 1100 mm(43.3 inches) 9.40 10"OW/m2 g _ _ Connector Original MC4 y0, 800W/m2,6 Highly reliable due to stringent quality control =b°° T0Wrm As a leading global manufacturer • Over 30 in-house tests (UV,TC,HF,and many more) 8 4.� of next generation photovoltaic S •• u'4m�mwi" 1 TEMPERATURE RATINGS MAXIMUM RATINGS In house testing goes well beyong certification requirements am products,we believe close 2.m 2001"//m2 Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C cooperation with our partners I _ •--_ 1 Temperature(NOCT) Maximum System 1000V DC)IEC)/ is Critical to success. With local presence around the globe,Trina is 0.o. Temperature Coefficient of Pens -0.43%/°C Voltage 9 600vDc(uL) able to provide exceptional service voltage(V) Temperature Coefficient of Von -0.32%/°C Max Series Fuse Rating 15A to each customer in each market Temperature Coefficient of Is, 0.047%/°C _ and supplement our innovative, Certified to withstand challenging environmental reliable products with the backing conditions of Trina as a strong,bankable • 130 km/hr wind load (2400 Pa) WARRANTY partner. We are committed • 900 kg snow load per module(5400 Pa) to building strategic,mutually 10 year Product Workmanship Warranty beneficial collaboration with installers,developers,distributors 25 year Linear Power Warranty and other partners as the (Please refer to product warranty for details) backbone of our shared success in CERTIFICATION �' LINEAR PERFORMANCE WARRANTY CERTI n driving Smart Energy Together. s '.. cc.,,„ I PACKAGING CONFIGURATION o 10 Year Product Warranty•25 Year Linear Power Warranty [� !, r' „`%"' spas Modules per box:24 pieces Trina Solar Limited " www.trinasolaccom `E t00% 1► Modules per 40'container:672 pieces Additional alae from Trfna ors It ISO id (E c VL w nV o rc� 90% Ad V S eor Ixreo v v of o ° Warranty Tr�nasolar O 80% ©20 3 TTCAUTIOnna Solar)READ nim ted.All rightFETY AND s reservved Spec STION pecificaONS tions included ncluded in hisRE USING ida aE osh et are subject to ,v9DUCT. 0c��, Tr�nasolarg change without notice. Smart Energy Together Years 5 10 15 20 25 Smart Energy Together AOS _... ■ Trina Solar 00/49t C