Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:269 ARRAY AZIMUTH:269 TOTAL ARRAY AREA: 288 ATTACHMENTSHALL EE SPACED ; � MATERIAL:Comp Shingle STORY: 2 Stories TOTAL ROOF AREA: 2361 GREATE THAN 24 INCHES t N CENTER J) IN ANY DIRECTION IOC WHERE!ERE ARRAY IS MP1 TOTAL AREA: 1080 00 LOCATED WITHIN 3 FEET OF A ROOF U00 EDGE,HIP, !LAVE OR RIDGE. eISISC 305,1.31.9, C n TOTAL ARRAY AREA IS X12% 0 0 OF TOTAL ROOF AREA. I ° 0 o o 0 0 0 i � Inv , I\ D ; ; _ ❑ i 1 o 0 O 0 0 ❑ o o ❑ 15371 SW Greenfield Dr O o 0 PI LEGEND o 0 3 0 (E) UTILITY METER & WARNING LABEL A 0 0 0 " ❑ 72 I ® INVERTER W/ INTEGRATED DC DISCO 1 & WARNING LABELS o 0 0 0 0 Front Of House ( A ® DC DISCONNECT & WARNING LABELS 4C9 AC DISCONNECT & WARNING LABELS CI. 0 JUNCTION BOX CI \____ 0 DC COMBINER BOX & WARNING 0 DISTRIBUTION PANEL & WARNING • ❑ Lc LOAD CENTER & WARNING LABELS I ° O DEDICATED PV SYSTEM METER a — CONDUIT RUN ON EXTERIOR ri --- CONDUIT RUN ON INTERIOR GATE/FENCE 0 5l1 INTERIOR EQUIPMENT CD °a SITE PLAN N a• Scale: 1/8" = 1' w Ali E 0 0 1' 8' 16' • m S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER • JB-9721590 00 MUJEEB, MOHAMMED MUJEEB RESIDENCE TrudyHomer PREM OMR DESCRPTXNk DESIGN: 10., CONTAINED SHALL NOT BE USED FOR 1HE r.l�;! NOR ST OF IT BENE EXCCLO ET SOIN%%HOLE INC., CompOutilm SYSou I,� s�la�it o NOR SHALL IT BE DISCLOSED IN ARCIT CR IN Mount Type C 15371 SW GREENFIELD DR ' y 3.92 KW PV PART TO O7HERS OUTSIDE THE RECIPIENTS � Array ORGAMWIT ZAnaN, EXCEPT IN CONNECTION H MONIES: PORTLAND, OR 97224 1HE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-245PC05/PA05.18 3055 teo,CA way SOLARCITY EQUIPMENT, WITHOUT THE WEPAGE NAME: SHEET REN DALE San Mateo,CA 94402 PERMISSION OF SOLARCnB INC. POWER-ONE # AURORA PVI-3.0-OUTD-S-US 5039222402 SITE PLAN PV 2 8/5/2013 (aeejV-an(1ss-2 s , y. ' (E) 2x4 0000000„... 0 0 i9*/ I 7'-9" / 5'-2" / 5'-7" -/ 5'-9" / (E) LBW SIDE VIEW OF MP1 RAFTER: (E) 2x4 © 24" O.C. A NTS CEILING JOIST: (E) 2x4 24" O.C. MAX SPAN: 7'-9" MAX STANDOFF DISTANCE: 72" O.C. PV MODULE 5/16" BOLT WITH LOCK INSTALLATION ORDER & FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) (2) SEAL PILOT HOLE WITH ZEP COMP MOUNT CAIMOWEIli NW, POLYURETHANE SEALANT. ZEP FLASHING C ;: -t'dln� M-—_ : (3) INSERT FLASHING. _j (E) COMP. SHINGLE . mY -- ice (4) PLACE MOUNT. (E) ROOF DECKING MILMOI IIIIII (5) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (E) RAFTER S1 STANDOFF Scale: 1 1/2" = 1' COPEIDENTIAL- THE INFORMAPON HEREIN .ae NUYBER: JB-9721590 0 0 PREMISE OVR Erc D ION: DESIGtt ��f� MOHAMMED "' CONTAINED SHALL NOT eE USED FOR THEMUJEEB, MUJEEB RESIDENCE TrudyHomer =� • NORBENFITSH ANYONE EXCEPT SOIN 1O TY INC, MIND SySER ..,,. So�arCity NOR SHALL IT BE DISCLOSED IN NHOIE OR IN CompMount Type C 15371 SW GREENFIELD DR 3.92 KW PV Array �� PART TO OTHERS OUTSIDE THE RECIPIENTS o ORGANIZATION,EXCEPT IN CONNECTION INTH ►RXXxis: PORTLAND, OR 97224 NE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-245PC05/PA05.18 ClearvIew Way SOLARCITY EQUIPMENT, NTHOUT THE MRITIEN PAGE NAVE SHELL REV DAIS Sm Mateo CA 94402 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-3.0-OUTD-S-US 5039222402 STRUCTURAL VIEWS PV 3 8/5/2013 (888)-SOL-CITY50 ,7s02se-2F:(650) )° y UPLIFT CALCULATIONS 08.05.2013 Soiaity SleekMountTM PV System Version# 13.9 Structural Design Software Prided oa Risk Category II PV System Type SolarCity'SleekMounr Comp Roof Comp Roof #of Layers 2 Roof Slope 23° Ratter Spacing 24"O.C. PV Module Orientation Landscape Tota Area of Array 282 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C Calculation Of Reduced Roof Snow Loads Ground Snow Load pg 25.0 psi ASCE Table 7-1 Surrounding Roof Snow 70% 17.5 p5 'ASCE Eq:7.41 Roof Snow Over PV Modules 70% 17.5 psf 'ASCE Eq:7.4-1 Wind Design.Criteria Wind Design Code ASCE 7-05 j Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 95 mph Fig.6-1 Exposure Category C ' Section 6.5.6.3 Roof Style Gable Roof 'Fig.6-11B/C/D-14A/B Mean Roof Height h 25 ft Section 6.2 Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.95 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh =0.00256(KN z}(Kzt)(Kd) ^2)(I) Equation 6-15 18.6 psf Ext. Pressure Coefficient(Up) GCp(Up) -0.88 Fig.6-118/C/D-14A/B Ext.Pressure Coefficient(Down) GCp(Down). 0.45 Fig.6-11B/Cf D-14AJB Design Wind Pressure p p= qh(GCp) Equation 6-22 Wind Pressure Up p(up) -16.3 psf Wind Pressure Down p(down) 10.0 psf Allowable Attachment Spacings(In.) if-Direction V-Direction Max Allowable Foot Spacing Landscape 72" 39" Max Allowable Cantilever Landscape 24" NA Standoff Configuration Landscape Staggered Max Standoff Tributary Area Trib 20 sf PV Assembly Dead Load W-PV 3 psf Net Wind Uplift at Attachment T-actual 285 lbs Uplift Capacity of Attachment T-allow 637 lbs Attachment Demand/Capadty DCR 44.7% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUYBER: JB-9721590 0 0 PREF OMER DESCRIPTION: DEM %!is CONTAINED SHALL NOT BE USED FOR THE MUJEEB, MOHAMMED MUJEEB RESIDENCE TrudyHomer �=��"=� • NOR F1TSH OF ANYONE EXCEPT IN%HOE INC., mowing Comp A bOlarCity NOR SHALL IT BE DISCLOSED IN NMOLE OR IN Comp Mount Type C 15371 SW GREENFIELD DR 3.92 KW PV Array " PART TO OTHERS OUTSIDE THE RECPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH WOOLSPORTLAND, OR 97224 THE SALE AND USE OF THE RESPECTIVE (16) TRINA SOLAR # TSM-245PC05/PA05.18 3055 aconic"Way ` SOLPERA CITY EMSOLINENT, %M TINUT THE MITTEN IN PAGE ME: SHEET: REY: DATE: 1(650)Son Mateo.638-1028 F:(650)638-1029 POWER-ONE # AURORA PVI-3.0-OUTD-S-US 5039222402 UPLIFT CALCULATIONS PV 4 8/5/2013 (888)-SOL-CITY(765-2489)www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #6 GEC TO (E) GROUND ROD Panel Number.CUTLER HAMMER Inv 1: DC Ungrounded INV 1 —( 1 )POWER—ONE # AURORA PVI-3.0—OUTD—S—US LABEL A —(16)TRINA SOLAR # TSM-245PC05/PA05.18 OR # 180498 AT PANEL WITH IRREVERSIBLE CRIMP Meter Number:23 151 011 Inverter, Zigbee, 3000W, 240V, 96% PV Module; 245W, 222.9W PTC, 40MM, Black Frame, MC4, ZEP Enabled RGC, CGC1 ' INV 2 Voc: 37.3 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER (E 200A MAIN SERVICE PANEL E) 200/2P MAIN CIRCUIT BREAKER Inverter 1 IND (E) WIRING COOPER 1 200A 2P Meter Socket n POWER—ONE DC+DO NOT ADJUST MIN.ACFIVATION V TACE / AURORA PVI-3.0—OUTD—S—US 0 DC- 4 1 String(s)Of 8 On MN(E) LOADS A EGC —i4."---1141 . . J n ■ -1.-N\ A L1 CO r- ` • •-- GFP/GFCI e.— DC+ N 03 m 20A/2P -i GND�- EGC/ '� DC+ I TDC+DOINOT ADJUST MIN.ACTIVATION V TACE OJ , ,� iRo 'Li, �/ GEC CI �� DC- DC- 1 'p 1 Strings)Of 8 On MPl i —� .— I I GND I EGC L EG(, 111 J J v (1)Conduit Kit; 3/4'FIAT N 1 — ,/ EGC/GEC G- Z-2 C., — T----GEC _ TO 120/240V SINGLE PHASE I U1IUTY SERVICE I IIi Voc* = MAX VOC AT MIN TEMP POI-(1)WTD-HAMMER,BR220 PV BACKFEED BREAKER A -(1)COOPER#B-Line Meter Socket 011 AC DC Breaker 20A/2P, 2 Spaces Meter Socket; 125A 4-14AWG,Ring Type —(1)AW CAP; B-Line Meter Socket Accessory I t (1)AWG 11O,TIIMA4-2 Black 3 (1)AWG#10,1HWN-2,Red (2)AWG/10. HAR PV E Black Voc 326.08vDC Isc =8.47 ADC ( AWG#10,THWN-2 White NEUTRAL Vmp =240 VAC Imp=14.5 MCO (1)AWG/10.Solid Bare Copper EGC Vmp =245.6 VDC Imp=7.98 ADC (1 —(1)AWG#6,NWN-2,Green EGC/GEC —(1)Conduit Kit 3/e EMT 2))Conduit Kit; 3/4'EMT * _ (2)AWG/10, PV WIRE,Block Voc 326.O8VDC Isc =$.47 ADC O���L�(1)AWG#10, Solid Bare Copper EGC Vmp =245.6 VDC Imp=7.98 ADC (1)Conduit Kit 3/4'EMT f j CONFIDENTIAL- NE INFORMATION HEREIN JOB NUMBER: J B-9 721 5 9 0 0 0 PREMISE ONlER DESa6P1I0N. DESIGN: %lady CONTAINED SHALL NOT BE USED FOR THE MUJEEB MOHAMMED 1 NORTAOF LL ANYONE INLNA1a.EE OR INC., MING SYSTEM; 15371 SW GREENFIELD DR MUJEEB RESIDENCE Trudy Homer ')i�'SoIarCitvPART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: PORTLAND, OR 97224 30 aea<Weil �+` THE SALE AND USE OF NE RESPEcii (16) TRINA SOLAR # TSM-245PC05/PAO5.18 SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PAGE NAE: SHEET: REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARaTY INC. 5039222402 T:(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PV1-3.0—OUTD—S—US THREE LINE DIAGRAM PV 5 8/5/2013 (888)-SCI-CITY(765-2489)e...salaraltycom . , CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 15371 SW Greenfield Dr e UTILITY SERVICE jI ii. Q � iii FINVERTER AND DC DISCONNECT SOLAR Q PHOTOVOLTAIC ON ROOF PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS A/C DISCONNECT PER NEC 690.17 - OPERATING VOLTAGE = 240V MAX CURRENT = 13.75 A CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-9721 5 9 0 00 PREMISE MINER DESCRP1l & DESIGN: `„gam CONTAINED SHALL NOT BE USED FOR THE MUJEEB, MOHAMMED v.= • BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTERMUJEEB RESIDENCE Trudy Homer ;���, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 15371 SW GREENFIELD DR 3.92 KW PV Array "�� Solaitity PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZABON, EXCEPT IN CONNECTION WITH MODULESPORTLAND, OR 97224: DE SALE AND USE OF THE RESPECTn,E (16) TRINA SOLAR # TSM-245PC05/PA05.18 joss aaaew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE Son Mateo,CA 94402 PERMISSION OF SOLARCITY INC. OWER-ONE # AURORA PVI-3.0-OUTD-S—US 5039222402 SITE PLAN PLACARD PV 7 8/5/2013 (888)—SOL—CITY(765-2489)www.sol y.corn Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC (AC)(AC)(P01) CAUTION (P01) Per Code: OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: CA Fire Guidelines MAXIMUM AC - v NEC 690.54 SECOND SOURCE IS NEC 690.64.B.4 OPERATING VOLTAGE PHOTOVOLTAIC SYSTEM Label Location: PHOTOVOLTAIC DC (DC)(INV) DISCONNECT Per Code: NEC 690.14.C.2 Label Location: Label Location: PV SYSTEM (AC)(P01) WARNING (DC)(INV) DISCONNECT FOR Per Code: UTILITY OPERATION ELECTRIC SHOCK HAZARD NEC 690.35(F) Label Location: THE DC CONDUCTORS OF THIS POWER- (DC)(INV) PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN MAXIMUM POINT CURRENT(Imp) Per UNGROUNDED AND INVERTER IS Per Code: MAY BE ENERGIZED UNGROUNDED MAXIMUM POWER-_v NEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEMv Label Location: VOLTAGE(Voc) WARNING (AC)(P01) SHORT-CIRCUIT Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD NEC 690.17(4) DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC)(CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS NEC 690.17(4) Label Location: TERMINALS ON BOTH LINE AND WARNING (P01) LOAD SIDES MAY BE ENERGIZED Per Code: IN THE OPEN POSITION INVERTER OUTPUT NEC 690.64.B.7 DC VOLTAGE IS CONNECTION ALWAYS PRESENT WHEN DO NOT RELOCATE SOLAR MODULES ARE THIS OVERCURRENT EXPOSED TO SUNLIGHT DEVICE Label Location: Label Location: WARNING (DC)(INV) PHOTOVOLTAIC POINT OF (P01) Per Code: INTERCONNECTION Per Code: ELECTRIC SHOCK HAZARD NEC 690.5(C) WARNING: ELECTRIC SHOCK NEC 690.17.4; NEC 690.54 IF A GROUND FAULT IS INDICATED HAZARD.DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE MAXIMUM AC Label Location: OPERATING CURRENT _ A (AC):AC Disconnect PHOTOVOLTAIC AC (AC)(P01) MAXIMUM AC DISCONNECT Per Code: OPERATING VOLTAGE _ V (C): Conduit (CB): Combiner Box NEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION (D)(POI) (LC): Load Center PHOTOVOLTAIC SYSTEM Per Code: (M): Utility Meter CIRCUIT IS BACKFED NEC 690.64.6.4 (P01): Point of Interconnection CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR '014 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San 2 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, Sc - OR Label Set ',��� Sofar' (888}50�-Cm8(-Mateo,F 6500))638-0 9 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. ZS Comp Edge Zone Calculations 1 of 4 ZS Comp Edge Zone Calculations 2 of 4 Lep S o l a r 5/28/13 Zep S o l a r 5/28/13 This set of calculations is intended to show that ZS Comp has sufficient strength to allow for attachment Down Force Spacing spacings of at least 48"in Edge Zones whether the modules are orientated in landscape or portrait.The Allowable Down Force Load calculations will vary the design variables to account for the worst case for each failure mode that is being down force spacing= module width x design load checked. Wind Down Calculations All variable the same as above except for roof pitch General Design Information: Roof Pitch Module Size: 39"x 65" Basic Wind Speed= 95 mph 14 30 45 System Weight= 3 psf Ground Snow Load= 30 psf GCN landscape= 0.5 0.9 0.9 GCN portrait= 0.4 0.9 0.9 Comp Mount Allowable Loads Uplift= 656 lbs design load landscape= 9.62 17.32 17.32 psf Lateral= 436 lbs design load portrait= 7.70 17.32 17.32 psf Down Force= 1147 lbs - Ro ,"019note:use 10 psf minimum � Snow Calculations Attachment Spacing Calculations ' 85818 V To account for unbalanced snow loads,ground snow loads will be used for roof pitches 30 degrees and Uplift Spacing A OREGON o lower.Per section 7.6.1 of ASCE 7-10 unbalanced snow loads do not need to be considered for slopes Allowable Uplift Load F � 7o.s above 30 degrees. � uplift spacing= eter �a° module length or width x design load EXPIRES. 12/31/14 Ground Snow Load= 30 psf Wind Uplift Calculations FOR PAGES 1-4 Roof Pitch ASCE 7-05 Method 2 14 30 GC Design Snow Load 29.11 25.98 psf p=qn N qn=0.00256 K,K„Kd V2 I (snow load spread over the length of the rafter) Basic Wind Speed= 95 mph Exposure= C Roof Zone= Edge Zone Down Force Load Roof Pitch Combinations: 14 30 Importance Factor= 1.0 KZ= 0.98 from Table 6-3 D+S= 31.16 25.10 psf Gable/Hip Roof K,= 1.0 per 6.5.7.2 D+W= 12.91 19.92 psf /orst Case Roof Pitch= 14 degrees Kd= 0.85 from Table 6-4 D+0.75W+0.755 31.59 32.46 psf Roof Height= 30 GCN landscape= -1.6 iscape effective area= 13.0 ft2 GCN portrait= -1.5 landscape down force spacing = 1147lbs x 144 in = 130" ortrait effective area= 21.7 ft2 39"x 32.46psf ftZ Plandscape= -30.79 psf qn= 19.25 psf Pportrait= -28.87 psf 11471bs in portrait down force spacing = 65"x 32.46psf x 144 f= 78" tZ Uplift Load Combination:0.6D+W(ASCE Section 2.4.1 equation 7) design load landscape= -29.05 psf design load portrait= -27.12 psf 656 lbs landscape uplift spacing = 39"x 29 05 psf x 144 in =83" Z portrait uplift spacing = 65"x 2712 psf x 144 in =54" ZS Comp Edge Zone Calculations 3 of 4167 ZS Comp Edge Zone Calculations 4 of 4 i 5/28/13 Zep S o tar 5/28/13 Zep S o a r Lateral Spacing Module Deflection Spacing The lateral force on the system increases as the pitch of the roof increases,but the amount of snow on landscape module spacing=-1.4545 x Maximum Uplift or Down Force Pressure+120.7273 the roof decreases for slopes greater than 30 degrees.With this in mind,the lateral force will be checked at 30 degrees with ground snow load and 45 degrees with sloped roof snow. portrait module spacing=-1.7917 x Maximum Uplift or Down Force Pressure+118.58 Allowable Lateral Load lateral spacing= module width x design load Maximum Uplift of Down Force Pressure= 32.46 psf Snow Calculations Ground Snow Load= 30 psf landscape module spacing=-1.4545 x 32.46 psf+120.7273 =73" Ps=C5 pf Roof Pitch= 31 45 degrees pf=0.7CeC5I Ig Ce= 0.9 C5= 0.71 0.45 Cf= 1.2 portrait module spacing=-1.7917 x 32.46 psf+118.58=60" pf= 22.68 22.7 psf I= 1.0 Ps= 16.1 10.2 psf Calculation Summary Calculated Edge Zone Spacing Roof Pitch Spacing Check Landscape Portrait 27 30 31 45 Uplift 83" 54" Design Snow Load 26.73 25.98 13.80 7.22 psf Down Force 130" 78" (snow load spread over the length of the rafter) 30" 27° 30° Lateral 74" 48" 45" Lateral Force Component Module Deflection 73" 60" Down Force Load Roof Pitch Combinations: 27 30 31 45 As can be seen in the table above,for Design Wind Speeds up to 95 mph and Ground Snow Loads up to 30 D+S= 13.50 14.49 8.65 7.22 psf psf with modules orientated in landscape,the system is strong enough to be installed at 72"on center in D+0.75W+0.755 10.46 11.24 6.88 5.95 psf the Edge Zone.When modules are installed in portrait,the spacing for edge zone installations can be 48" on center for most roof pitches.For roof pitches that are greater than 27°but less than 31°,the maximum 30 degree roof pitch attachment spacing is 45". 292lbs in landscape lateral spacing= = 74" 39"x 14.49 psf x 144 ftz 292lbs in portrait lateral spacing= x 144 65"x 14.49 psf f=45" tZ Portrait spacing is less than 48".Try roof pitch of 27 degrees 292lbs in portrait lateral spacing = x 144 65"x 13.50 psf ftz =48" mono multi solutions Trinamount II FOR PITCHED ROOF TSM-PC05 / PA05.18 mono multi solutions ELECTRICAL DATA @ STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCOS/PA05.18 PC/PA05.18 PC/PA05.18 PC/PAO5.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-Prux(Wp) 225 230 235 240 245 • IIIIIIIIIMMIN 01+301+3 TrnamountIi O YEAR Power Output Tolerance P.ux(%) 29.4 29.8 30.1 0/+3.40/+3 Maximum Power Voltage-We(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE MazimumPowerCU Current-kw 7.66 7.72 7.81 7.89 7.98 by TrmaSOlar AND MOUNTING SYSTEM E Open Circuit Voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 Short Circuit Current-Isc(A) 8.20 8.26 8.31 8.37 8.47 FOR PITCHED ROOF 5)( Module Efficiency nm(%) 13.7 14.1 14.4 14.7 15.0 FASTER TO INSTALL AL �A Values at Standard Test Conditions STC(Air Mass AM I.5,Irradiance 1000w/es',Cell Temperature 25°C). ULTRA LOW ELECTRICAL DATA @ NOCT TSM-225. TSM-230 '.TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE - MaximumPowerVol 164 168 172 27. 178 ,,µL NG 6 ® Maximum Power Voltage(V) .26.9 27.1 27.4 27.7 27.8 GROUND BOND CONNECTION MaximumPower Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UI MINIMUM CRITERIA Open Occult Voltage)V) 33.8 33.9 34.0 34.1 34.2 _ Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 NOCT:Irradiance at 800W/m'.Ambient Temperature 20°C,Wind Speed 1 M/s. Bock View MECHANICAL DATA ', Solar cells Multicrystalline 156.156mm(6 inches) I t tt Cel orientation 60 cells(6 x 10) ;i 111 Module dimension 1650.992•40mm(64.95 x 39.05.1.57 inches) III , \ - t-.1-k,~ Weight 20.3kg(44.8 Ib) a Glass High honsparancy solar glass 3.2mm(0.13 inches) f; Frame Anodized aluminium alloy 1 _��--� J-Box IP 65 rated AA Cables/Connector Photovoltaic Technology cable 4.0mm'(0.006 inches'), 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9P°.. l0oow/m- i TEMPERATURE RATINGS Tao So0w7mt Nominal Operating Cell 46°C(32°C) 6 _.__.. _._____._-_.. _-_.__ Temperature(NOCT) a 600w/m' 51. Temperature Coefficient of P,... -0.43%/°C S 4 400W/n0_ U Temperature Coefficient of Voc -0.32%/°C 3 20ow/m'".. _... _.. _ Temperature Coefficient of Isc 0.047%/°C SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY 0� 01. 101° 209° 30°° 401° ArilINNOVATIVE MOUNTING SYSTEM SOLUTION. Voltage(V) MAXIMUM RATINGS MIEN COMPOSITION SHINGLE Operational Temperature -40-085°C Mtn Trina Solar is introducing Trinamount"---the fastest,easiest and least Maximum System Voltage 1000V DC(IEC)/600V <o expensive way to mount PV modules onto residential and commercial DC(uL) rooftops. With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION i faster than conventional mounting systems.Trinamount connects cu r I directly to the module frame; eliminating the need for long rails, CE ISO PV CYCLE i11 a U$ WARRANTY ism STANDING SEAM ROOF By drastically reducing the number of parts, cost of materials and v "�"` / 10 year workmanship warranty installation time,Trinamount offers the optimal solution for residential ��� ®. Z 25 year linear performance warranty and commercial installations. , (Please refer to Ndetails) wi product warranty los y toMP4lB3 T •Trnasolar• 'W •Trn aisolar CAUTION: SoDSAEiBEFORE USING power behind the panel COMPAsTherowes behnd thepanet ® Solar Limited. rights reserved.Specifications incl�nisdatasht are subject to change without notice. SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep Compatible"'modules i aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition • of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 46/as layer of shingle strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions ,,siliW 40 Secure Leveling Foot to the Comp Mount using machine Screw ., Place module �� Components -- ilk, �j;=4171--r /� 5/16"Machine Screw * ' i =l � Leveling Foot Lag Screw F 0 Comp Mount Comp Mount Flashing ,--- --74,,4 • �/ n�,vq i c) irii '�.a a `�oMV4TjBI b '.ex `, # SOIN�'ty© January 2013 1y0o � LISTED *y SolarCity January 2013 aowe-ore= o _. . , , , ��Renewab/e Energy Solutions i1)R()R A TECHNICAL. DATA VALUES iV-3.O-OUTD-IS PVI-3,6 -tJS P Nominal Output Power W 3000 3600 4200 - Maximum Output Power W 3000 3300" 3300" 3600 4000" 4000" 4200 4600" 4600" d Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Z Input Side(DC) Number of Independent MPPT Channels 2 2 2 P.14(1-3.04'1 Od Maximum Usable Power for Each Channel W 2000 3000 3000 Gt' Absolute Maximum Voltage(Vmax) V 600 600 600 O Start-Up Voltage(Vstart) V . 200(ad).120-350) 200(adj.120-350) 200(ad).120-350) PVI-3.6-TI td Full Power MPPT Voltage Range V 160-530 120-530 140-530 vt Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7xVstart-580 Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 I°" s Maximum Usable Current per Channel A 10 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20 20 Number of Wire Landing Terminals Per Channel 2Pairs(1on-S version) 2Pairs(1on-S version) 2Pairs(1on-S version) ( ENERAL P F C I -I C A 1 1()N S Array Wiring Termination Terminal block,Pressure Clamp,AWGI0.AWG4 'yfi -y j ( `{ { Output Side(AC) Q t J.1 [ )(')0( /C)o�+F F ii-, Grid Connection Type 10/2W Split- Split- Split- 0/3W 10/2W 10/2W 0/3W 10/2W 10/2W g/3W 10/2W Q Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 je <. . Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 © MaximumCurrent(lacmax) Axles 14.5 14.5 12 17.2 16 16 20 20 20 The most Common residential inverter is the ideal size for an average- Cd Power Factor >0.996 >0.995 >0.995 Total Harmonic Distortion At Rated Power % <2 <2 <2 sized family home. This family of single-phase string inverter ii;' Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG10-AWG4 ut complements the typical number of rooftop solar panels,allowing " Protection Devices home-owners to get the most efficient energy harvesting for the Reverse Polarity Protection Yes Yes Yes size of the r0 This rugged outdoor inverter has been designed ,. . ...„,,,,,,,.<,,„,,,,e. Orer-Volta a ProtectionType p 99eg Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel as a completely sealed unit to withstand the harshest environmental y'° PVArrayGround Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) P conditions. Anti-Islanding Protection Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 • ` requirements requirements requirements Over Voltage Protection Type Varistor,2(L,-L/L,-G) Varistor,2(L,-L,/L,-G) Varistor,2(L,-L,/L,-G) One of the key benefits of the Uno family of single-phase inverters Maximum AC OCPD Rating A 20 20 15 25 20 20 25 25 25 is the dual input section to process two strings with independentr Ed•MY Maximum Efficiency % 96.9 97 97 MPPT especially useful for rooftop installations with two different GEC Efficiency % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time .. a 4 Operating Performance power tracking and improved energy harvesting. # Stand-by Consumption W <s <8 8 Night time consumption WwMs <0.6 <0.6 <0.6 N Communication The transformerless operation gives the highest efficiency of up to User Interface 16 characters x 2 lines LCD display Remote Monitoring(1xRS485 incl.) AURORA-UNIVERSAL(opt) 97.03'x. The wide input voltage range makes the inverter suitable to Wired Local Monitoring(1xRS485 ind.) PVI-USB-R5485_232(opt),PVI-DESKTOP(opt) low power installations with reduced string size. W Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt) ............... Environmental Ilk Ambient Air Operating Temperature Range °F(°C) 13 to+140(-25 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with derating above 131(55) derating above 131(55) derating above 113(45) " • a,,. Ambient Air Storage Temperature Range F(°C) -40 to 176(-00 to+80) -40 to 176(40 to+80) -40 to 176(-00 to+80) eafBMra► Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Features r Acoustic Noise Emission Level db(A)WIm <50 <50 <50 '� `` "o i" Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X NEMA 4X • Each inverter is set on specific grid codes which can be selected in the field Cooling Natural Convection Natural Convection Natural Convection Dimensions(H x W x D) in(mm) 33.8 x 12.8 x 8.7(859 x 325 x 222)-5 Version • Single phase Output Weight Ib/(kg) <47.3(21.3)-5 version <47.3(21.3)-5 version <47.3(21.3)-S version • Dual input sections with independent MPPT,'allows optimal energy harvesting from two sub-arrays oriented in Mounting System Wall bracket Wall bracket Wall bracket Trade size KOs:(2ea x 1/2')and Trade size KOs:(tea x 1/2")and Trade size KOs:(tea x 1/2')and different directions Conduit Connectionsm (2ea x 1-1/413 places side,front, (2ea x 1-1/41,3 places side,front, (2ea x 1-1/413 places side,front, • wide input range - :. rear) rear) rear) • High speed and revise MPPT algorithm rRhm for real time DC Switch Rating-(Per Contact) AN 25/600 25/600 25/600 kJ P power tracking and improved energy harvesting Sa • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level Transformerless(Floating Array) Transformerless(Floating Array) Transformerless(Floating Array) the entire input voltage and output power range Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 Safety Approval ,CSA", ‘CSA,. cCSA°, • Outdoor enclosure for unrestricted use under any environmental conditions Warranty • Integrated DC disconnect switch in compliance with international Standards(-S Version) Standard Warranty years 10 10 10 Extended Warranty years 15&20 15&20 15&20 • RS-48S communication interface(for connection to laptop or datalogger) Available Models • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US With DC Switch and Wiring Box PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI.4.2-OUTD-S-US `AM data is subject to change without notke ..Capability enabled at nominal AC voxage and with sufficient DC power evadable AURORA Ut W 1 »•when equipped walloptional DC Swatch andwinng Box AURORA UNO 3: SP�® CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Ro1-Hevn stock Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 5311 09 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 5311 89 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment for Use With Distributed Energy Resources(January 28,2010) DQD 507 Rev.2009-09-01 Page.1 • Intertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing TSM-200PA05,TSM-205PA05,TSM-210PA05,TSM-215PA05,TSM-220PA05,TSM-225PA05,TSM- Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing 230PA05,TSM-235PA05,TSM-240PA05,TSM-245PA05 and TSM-250PA05. Report. This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be TSM-200PA05.05,TSM-205PA05.05,TSM-210PA05.05,TSM-215PA05.05,TSM-220PA05.05,TSM- 225PA05.05,TSM-230PA05.05,TSM-235PA05.05,TSM-240PA05.05,TSM-245PA05.05 and TSM- applied only at the location of the Party Authorized To Apply Mark. 250PA05.05. Applicant: Trina Solar Ltd Manufacturer: Changzhou Trina Solar Energy Co., Ltd. TSM-200PA05.10,TSM-205PA05.10,TSM-210PA05.10,TSM-215PA05.10,TSM-220PA05.10,TSM- 225PA05.10,TSM-230PA05.10,TSM-235PA05.10,TSM-240PA05.10,TSM-245PA05.10 and TSM- No.2 Tian He Road,Electronic Park, No.2 Tian He Road,Electronic Park, 250PA05.10. Address: New District,Changzhou,Jiangsu Address: New District,Changzhou,Jiangsu TSM-200PA05.15,TSM-205PA05.15,TSM-210PA05.15,TSM-215PA05.15, Country: China Country: China Models: TSM-220PA05.15,TSM-225PA05.15,TSM-230PA05.15,TSM-235PA05.15, Contact: Ms.Lihua Yin Contact: Ms.Lihua Yin TSM-240PA05.15,TSM-245PA05.15 and TSM-250PA05.15. Phone: +8651968879039 Phone: +8651968879039 FAX: +8651968879006 FAX: +8651968879006 TSM-200PA05.18,TSM-205PA05.18,TSM-210PA05.18,TSM-215PA05.18,. Email: lihua.yin@trinasolar.com Email: lihua.yin@trinasolar.com TSM-220PA05.18,TSM-225PA05.18,TSM-230PA05.18,TSM-235PA05.18, Party Authorized To Apply Mark: Same as Manufacturer TSM-240PA05.18,TSM-245PA05.18 and TSM-250PA05.18. Report Issuing Office: Menlo Park,CA,USA Control Number: 4003042 Authorized by: .1.40t/th. TSM-155DA01,TSM-160DA01,TSM-165DA01,TSM-170DA01,TSM-175DA01, TSM-180DA01,and TSM-185DA01. illiam T.St rr,Certification Manager TSM-155DA01.05,TSM-160DA01.05,TSM-165DA01.05,TSM-170DA01.05, TSM-175DA01.05,TSM-180DA01.05,and TSM-185DA01.05. COUS Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark is for the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certifcation mark is restricted to the conditions laid out In the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 165 Main Street,Cortland,NY 13045 Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699 Standard for Flat-Plate Photovoltaic Modules and Panels UL 1703-Third Edition,March 15,2002,with revisions through May 23,2011 Standard(s): Requirements for Flat-Plate Photovoltaic Modules and Panels,ULC/ORD-C1703-01-First Edition, ammended October 2001 Product: Flat Plate Photovoltaic Modules Brand Name: Trina Solar ATM for Report SH11031298-001 Page 1 of 2 ATM Issued: 19-Jul-2011 ATM for Report SH11031298-001 Page 2 of 2 ATM Issued: 19-Jul-2011 ED 8.9.4(8-Jan-10)Mandatory ED 8.9.4(8-Jan-10)Mandatory