2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address:
City: 1 i wirl (R.- Zip: R 7M4 -
Owner's Na '' II
�'U 1„t°,,I s Cc it- Date: ti I zo a
Contractor's Name: SolarCityCorporation Poration
CCB #: 180498
w .
Design Parameters of the Property/Structure
If"Yes",does not
Flood Hazard Is the installation D Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? ® No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure �� Yes If"Yes", qualifies for
C or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes",qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. 0 No
Snow Load
Is the Ground Snow
Installations on all Load 50 psf or less?
- structures other than If"Yes",qualifies for
above ❑ Yes the prescriptive path.
0 No
1
I:Building/Fotms/PhotoVoltaic-Checklist.docx ,
I►
,
Is the construction
a
Type of material wood and does Yes If"Yes",qualifies fox
the construction qualify ❑ No the prescriptive path.
Construction as °conventional light f
frame"construction? �
Is the spacing 24 inches
or less?
❑ Yes If"Yes",qualifies for
Pre-engineered trusses• the prescriptive path.
N, No
Roof framing •
members Is the spacing 24 inches
or less?
If"Yes", qualifies for
Nominal lumber. )OYesthe prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes",qualifies for
racking less than or ❑ No the prescriptive path. Y
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ® Yes If"Yes",qualifies for
with Section 305.4(3)of 0 No the prescriptive path.
. the 2010 Oregon Solar
Code?
0 Metal
Single layer If roofing material is
Roofing Check the type of 0 of wood one of the three types
material roofing material shingle/shake checked,qualifies for
Max.two layers the prescriptive path.
Xof composition
shingle.
Is the roof mounted ® Yes
Connections of solar assemblyIf"Yes",qualifies for
the solar assembly connected to roof 0 No the prescriptive path. -
to the roof framing or blocking
directly? '444
2
1;/Building/Forms/PhotoVoltaic-Checklist.docx
4
❑ Yes If"Yes",qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes",qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted If the spacing falls
solar S stems Spacing of clams? Minimum 24 inches
Y p within 24 inches and 60
directly to inches inches,qualifies for the
Maximum 60 inches
standing seam prescriptive path.
metal panels Width of roofing If the width of the panel
panels? 18 inches or less
is less than 18 inches,
inches qualifies for the •
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. tls"thickness, ❑ Yes
decking connected to If"Yes",qualifies for
framing members 0 No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
3
I:/Building/Fomes/Photovoltaic-Checklist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings,structures,
property lines,and,as applicable,flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size,type,and
spacing)and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer:
Model Number: (� i-- ZA 5 v5
Listing Agency: UL1703
•
4
1:Building/Forms/PhotoVoltaic-Checklistdocx