Loading...
Report (55) "rs Y° 56) /51/e7,sv /3- City of TigardCV Building Division 2 9 13125 SW Hall Blvd,Tigard,OR 97223 MAY 2014 Phone: 503.718.2439 Fax: 503.598.1960 IT 'OF fiGARD TI G A R D Inspection Line: 503.639.4175 www.tigard-or.gov BUILDING IvISI01 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: G Hyo S a) 8 r C�, tAio., -1 PL . City: T J Zip: 61711'1 Owner's Name: y*0 t.4 t pdJQ .k Date: 5/18//,-/ Contractor's Name: S tt kor v.prti CCB #: ) Design Parameters of the Property/Structure If"Yes",does not Flood Hazard Is the installation 0 Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? IX No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure �'� Yes If"Yes",qualifies for "C"or less? 0 No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes",qualifies for family townhomes ,f Yes the prescriptive path. and/or their accessory Ground structures. 0 No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? • structures other than If"Yes",qualifies for ❑ Yes the prescriptive path. above ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines,and,as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size,type, and spacing)and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: (cor.j , S (cr Model Number: C_5 (©e— �5 5 Listing Agency: U A (,) r5 'Lc j o rk-+0 r . 4 I:Building/Forms/PhotoVoltaic-Checklist.docx Is the construction Type of material wood and does R Yes yP the construction qualify If"Yes",qualifies for Construction ❑ No the prescriptive path. as "conventional light frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. 0 Yes the prescriptive path. ❑ No Is the combined weight IZ Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation [ J' Yes layout in accordance NI with Section 305.4(3)of If"Yes", qualifies for the 2010 Oregon Solar 0 No the prescriptive path. Code? 11 Metal Single layer If roofing material is Roofing Check the type of . , of wood one of the three types material roofing material shingle/shake checked,qualifies for Max. two layers the prescriptive path. of composition shingle. Is the roof mounted Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist.docx F 0 Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. n No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches,qualifies for the Standing seam prescriptive path. metal panels If the width of the panel Width of roofing is less than 18 inches, panels? 18 inches or less qualifies for the • inches prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes",qualifies for 0 fastener? the prescriptive path. ❑ No Is the roof decking of WSP min. f2"thickness, 0 Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaic-Checklist.docx CanadianSolar • Make The Difference CS6P-255 1 260M THE BEST IN CLASS Canadian Solar's modules are the best in class in terms of power output and long term reliability. Our meticulous product design and stringent quality control ensure our modules deliver a higher PV energy yield in live ^ PV system as well as in PVsyst's system simulation.Our in-house PV testing • facilities guarantee all module component materials meet the highest quality standards possible. 'Black frame product can be provided upon request. PROD97UCT WARRANTY&INSUue from RANCE fig PRODUCT KEY FEATURES 10096— Added ValWarrant Excellent module efficiency 9o% Y up to 16.16% eon Eft'c ens 0% 5 10 15 20 25 Outstanding performance at low irradiance ees,-s above 96.5% 25 Year Industry leading linear power output warranty 10 Year Product warranty on materials and workmanship Positive power tolerance 25 Canadian Solar provides 100%non-cancellable,immediate warranty — up to 5w YEARS insurance WTrra my (n5ulanee 11111 High PTC rating up to 91.31% PRODUCT&MANAGEMENT SYSTEM I CERTIFICATES* P C IEC 61215/IEC 61730:VDE/MCS/CE/CEC AU/CQC UL 1703/IEC 61215 performance:CEC listed(US)/FSEC(US Florida) UL 1703:CSA I IEC 61701 ED2:VDE I IEC 62716:TUV I IEC60068-2-68:5G5 41 Self-cleaning&anti-glaring PV CYCLE (EU)I UN19177 Reaction to Fire:Class 1 vlf-CSee module surface available 1S09001:2008 I Quality management system 1SOT516949:2009 I The automotive industry quality management system IP67 junction box available 15014001:2004 I Standards for environmental management system o long-term weather endurance QC080000:2012 I The certificate for hazardous substances process management OHSAS 18001:2007 I International standards for occupational health and safety *Please contact your sales representative for the entire list of certificates applicable to your products Heavy snow load " c$pVS ( BRif ®PVCVCLE ✓ up to 5400pa 4OOP, CANADIAN SOLAR INC. 1pSalt mist,ammonia and blowing sand Founded in 2001 in Canada, Canadian Solar Inc., (NASDAQ:CSIQ) is one of the resistance,apply to seaside,farm and world's largest and foremost solar power companies.As a leading manufacturer of Sy:tem desert environment solar modules and PV project developer with about 6 GW of premium quality Reliability modules deployed around the world in the past 12 years,Canadian Solar is one of the most bankable solar companies in Europe, USA,Japan and China. Canadian Solar operates in six continents with customers in over 70 countries and regions. Canadian Solar is committed to providing high quality solar products,solar system solutions and services to customers around the world. ® , ir,Q VI wvnv.l rodiansol-r oin C a7 Sofia i .. *'T:rte suppo tcacan adia. olar. cum 5a tip v le e a�Nlest, '� A 0 �n _Iph ta n"i Kl[6�C*eeo* 1, t t so CanadianSolar Make The Difference ELECTRICAL DATA( STC MODULE I ENGINEERING DRAWING Electrical Data C56P-255M CS6P-260M Rear View Frame Cross Section Nominal Maximum Power(Pmax) 255W 260W Optimum Operating Voltage(Vmp) 30.W 30.7V Optimum Operating Current(Imp) 8.35A 8.48A - H e Open Circuit Voltage(Voc) 37.7V 37.8V I�I, Short Circuit Current(Isc) 8.87A 8.99A. se`I'°°A-A II Module Efficiency 15.85% 16.16% I I 35 0 Operating Temperature -40'C"+85°C j I I 7 Maximum System Voltage 1000V(IEC)/1000V(UL)/600V(UL) I Maximum Series Fuse Rating 15A .r..2-. ------ Application Classification Class A Asa I - > o, Power Tolerance 0-+5W I i °Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrum AM 1.5 and cell temperature of 25°C. ! i I 115 J_ ELECTRICAL DATA I NOCT ' ;_ 9B? Electrical Data CS6P-255M CS6P-260M i Nominal Maximum Power (Pmax) ,, 184W 188W Optimum Operating Voltage(Vmp) 27.8V 28.0V Optimum Operating Current(Imp) 6.62A 6.70A Open Circuit Voltage(Voc) 34.6V 34.7V C56P-260M I I-V CURVES Short Circuit Current fisc) 7.18A 7.28A *Under Nominal Operating Cell Temperature(NOCT),irradiance of 800 Wim',spectrum AM 1.5, to - - 10, ambient temperature 20'C,wind speed 1 m/s. 8 i 8 MODULE I MECHANICAL DATA 8 8 j v T ` Specification Data Cell Type Mono-crystalline,6inch -6 a6 Cell Arrangement 60(6x10) 'z' s6 _ Dimensions 1638 x982 40mm(64.5x 38.7x 1.57M) o us Weight 18.5kg(40.8 lbs) a: - _ a,, Front Cover 32mm tempered glass 3 3 } Frame Material Anodized aluminium alloy —t000w/m2 ` —5°C 2 -800w/m2 2, -25'C J-BOX 0167,3 diodes 600n/m2 --as"c Cable 4mm'(IEC)/4mm'&12AWG 1000V(UL1000V)/ 1 —boon/m2 1 i —sst 12AWG(U1600V),1000mm 0 0 Connectors. MC4 or MC4 comparable 0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40 45 Standard Packaging 24pcs,504kg(quantity and weight per pallet) Voltage(V) Voltage(V) Module Pieces per Container 672pcs(40'HQ) TEMPERATURE CHARACTERISTICS Specification Data Partner Section Temperature Coefficient(Pmax) 0.45%/°C Temperature Coefficient(Voc) -0.35%pC Temperature Coefficient(lsc) 0.060%/°C Nominal Operating Cell Temperature 4512°C PERFORMANCE AT LOW IRRADIANCE Industry leading performance at low irradiation environment, +96.5% module efficiency from an irradiance of 1000w/m'to 200w/m°(AM 1.5,25"C) "The specifications made herein may deviate slightly and are not guaranteed.Due to ongoing innovation,research and product enhancement we reserve the right to make any adjustments to the information contained herein at any time withoutnotice..Please always obtain the most recent revision of datasheet which shall be dulyin orparated into the binding contract mode by the parties governing all transactions related to the purchase and sale of the products described herein. ` www Lorridia,o,ar.com lea 5 1..I c Y 2 Id.PI ht r.ved su pport,,,,eanadianso lar.eom