Report (50) //14,s7-2_c2/6--- o0)-?
Page 1 N:\JOBS Stone Bridge\1917\304 Beams\304-BEAM A.dsn S-VJ r/( cf<tr
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2013.4 03/06/15 15:49:30
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2013.4 EXPIRES ON 3/31/2015. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-BEAM A
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 8.500' 16.000' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 8543 9048 4827 0.137 0.187
ALLOWABLE 9188 20246 8035 0.395 0.593
STRESS INDICES 0.930 0.447 0.601 L/1038 L/762
LOAD CASE 1 1 1 3 3
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
*** PROVIDE ANCHORAGE FOR UPLIFT AT SUPPORTS. ANCHORAGE DETAIL
TO BE PROVIDED BY PROJECT DESIGNER.
CONNECTION
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
6" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 121" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1 SPAN 2
12.000' 6.500'
TOTAL SPAN: 18.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 183.8 PLF 0.000 12.000
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 12.000
+ALL 2 *UNIF DEAD FLOOR SIDE 183.8 PLF 0.000 6.500
+ALL 2 UNIF WEIGHT BEAM 11.9 PLF 0.000 6.500
+1 1 *UNIF LIVE FLOOR SIDE 490.0 PLF 0.000 12.000
+1 2 *UNIF LIVE FLOOR SIDE 490.0 PLF 0.000 6.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 12.000
+2 2 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 6.500
r '
Page 2 304-BEAM A.dsn
+3 1 *UNIF LIVE FLOOR SIDE 490.0 PLF 0.000 12.000
+4 2 *UNIF LIVE FLOOR SIDE 490.0 PLF 0.000 6.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 -9048 4827 1.00
2 -2582 1377 0.90
3 8294 4754 1.00
4 -3445 2720 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2 BRG#3
1 3341 8543 801
2 953 2438 229
3 3416 6734 -652
4 877 4246 1681
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2 BRG#3
1 953 2438 229
2 953 2438 229
3 953 2438 229
4 953 2438 229
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2 BRG#3
1 2387 6105 572
2 0 0 0
3 2463 4297 -880
4 -76 1808 1453
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2 BRG# 3
3.500 3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.124 0.395 L/1146 0.174 0.593 L/819
1 2 -0.013 0.212 L/6087 -0.018 0.318 L/4350
2 1 0.000 0.395 0.050 0.593 L/2869 0.050 0.074
2 2 0.000 0.212 -0.005 0.318 L/15245 -0.005 -0.008
3 1 0.137 0.395 L/1038 0.187 0.593 L/762
3 2 -0.026 0.212 L/2970 -0.030 0.318 L/2507
4 1 -0.014 0.395 L/10337 0.037 0.593 L/3851
4 2 0.015 0.212 L/5232 0.011 0.318 L/7070
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.447 0.601
2 0.142 0.190
3 0.410 0.592
4 0.170 0.339
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
r '
Page 3 304-BEAM A.dsn
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-BEAM B.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:34:35
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-BEAM B
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.OE
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 10.000' 7.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 2959 8450 2887 0.152 0.214
ALLOWABLE 9188 20246 8035 0.390 0.585
STRESS INDICES 0.322 0.417 0.359 L/927 L/658
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
10" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
12.000'
TOTAL SPAN: 12.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xl (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 131.3 PLF 0.000 12.000
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 12.000
+1 1 *UNIF LIVE FLOOR SIDE 350.0 PLF 0.000 12.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 12.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 8450 2887 1.00
Page 2 304-BEAM B.dsn
2 2453 838 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 2959 2959
2 859 859
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 859 859
2 859 859
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2100 2100
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.152 0.390 L/927 0.214 0.585 L/658
2 1 0.000 0.390 0.062 0.585 L/2266 0.062 0.093
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.417 0.359
2 0.135 0.116
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-BEAM C.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:36:55
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-BEAM C
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LVL 2950Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 13.000' 8.500' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 1960 2906 1872 0.015 0.021
ALLOWABLE 9188 20246 8035 0.207 0.310
STRESS INDICES 0.213 0.144 0.233 L/5061 L/3608
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
8" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN 1
6.500'
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 161.3 PLF 0.000 6.500
+ALL 1 UNIF WEIGHT BEAM 11.9 PLF 0.000 6.500
+1 1 *UNIF LIVE FLOOR SIDE 430.0 PLF 0.000 6.500
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 6.500
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 2906 1872 1.00
Page 2 304-BEAM C.dsn
2 834 537 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 1960 1960
2 563 563
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 563 563
2 563 563
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1398 1398
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.015 0.207 L/5061 0.021 0.310 L/3608
2 1 0.000 0.207 0.006 0.310 L/12568 0.006 0.009
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.144 0.233
2 0.046 0.074
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-BEAM D.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:40:49
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-BEAM D
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2950Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 9.750' 9.750' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 5883 30034 5801 0.450 0.647
ALLOWABLE 13781 52849 16240 0.690 1.035
STRESS INDICES 0.427 0.568 0.357 L/552 L/384
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 8" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 8" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
21.000'
TOTAL SPAN: 21.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xl (FT) X2 (FT)
+ALL 1 *UNIF DEAD FLOOR SIDE 146.3 PLF 0.000 21.000
+ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 21.000
+1 1 *UNIF LIVE FLOOR SIDE 390.0 PLF 0.000 21.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 21.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
Page 2 304-BEAM D.dsn
1 30034 5801 1.00
2 9128 1763 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 5883 5883
2 1788 1788
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1788 1788
2 1788 1788
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 4095 4095
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.450 0.690 L/552 0.647 1.035 L/384
2 1 0.000 0.690 0.197 1.035 L/1263 0.197 0.295
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.568 0.357
2 0.192 0.121
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-BEAM E.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:45:23
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-BEAM E
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 16" LP LVL 2950Fb-2.0E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 0.000' 9.750' SIDE L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 4411 21728 4195 0.298 0.469
ALLOWABLE 13781 52849 16240 0.690 1.035
STRESS INDICES 0.320 0.411 0.258 L/833 L/530
LOAD CASE 3 3 3 3 3
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
***ATTACH TWO PLIES WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 3 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** CONTACT HANGER MANUFACTURER TO VERIFY ABILITY OF HANGER TO DISTRIBUTE LOAD
*** CONCENTRATED SIDE LOADS MUST BE EQUALLY DISTRIBUTED TO ALL PLIES.
THIS CONNECTION AND RESTRAINT OF THE TORSION INDUCED BY THE SIDE
LOAD ON THE MEMBER ARE THE RESPONSIBILITY OF THE PROJECT DESIGNER.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
21.000'
TOTAL SPAN: 21.00 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 14.000 21.000
+ALL 1 *UNIF DEAD FLOOR SIDE 73.1 PLF 0.000 21.000
+ALL 1 UNIF WEIGHT BEAM 24.0 PLF 0.000 21.000
ALL 1 *UNIF DEAD FLOOR SIDE 19.1 PLF 0.000 14.000
Page 2 304-BEAM E.dsn
ALL 1 UNIF DEAD ROOF TOP 15.0 PLF 14.000 21.000
ALL 1 *CONC DEAD FLOOR SIDE 141.5 LBS 14.000
+1 1 *UNIF LIVE FLOOR SIDE 146.3 PLF 0.000 21.000
1 1 *UNIF LIVE FLOOR SIDE 38.2 PLF 0.000 14.000
1 1 UNIF LIVE ROOF TOP 22.5 PLF 14.000 21.000
1 1 *CONC LIVE FLOOR SIDE 283.1 LBS 14.000
+2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 21.000
2 1 *UNIF LIVE FLOOR SIDE 0.0 PLF 0.000 14.000
2 1 UNIF LIVE ROOF TOP 0.0 PLF 14.000 21.000
2 1 *CONC LIVE FLOOR SIDE 0.0 LBS 14.000
+3 1 *UNIF LIVE FLOOR SIDE 195.0 PLF 0.000 21.000
3 1 *UNIF LIVE FLOOR SIDE 50.9 PLF 0.000 14.000
3 1 *CONC LIVE FLOOR SIDE 377.5 LBS 14.000
4 1 UNIF LIVE ROOF TOP 30.0 PLF 14.000 21.000
* INDICATES SIDE LOAD.
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 18524 3665 1.00
2 7879 1687 0.90
3 21728 4195 1.00
4 8267 1817 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 3392 3908
2 1380 1874
3 4028 4411
4 1415 2049
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1380 1874
2 1380 1874
3 1380 1874
4 1380 1874
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2013 2034
2 0 0
3 2648 2537
4 35 175
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
CONCENTRATED LOADS
SPAN TYPE Wl (LBS) X1 (FT) MIN BRG (IN)
1 DEAD 141.5 14.000 3.000
1 LIVE 377.5 14.000 3.000
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.230 0.690 L/1081 0.401 1.035 L/620
2 1 0.000 0.690 0.171 1.035 L/1456 0.171 0.256
3 1 0.298 0.690 L/833 0.469 1.035 L/530
Page 3 304-BEAM E.dsn
4 1 0.008 0.690 L/30098 0.179 1.035 L/1389
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.350 0.226
2 0.166 0.115
3 0.411 0.258
4 0.156 0.112
SLENDERNESS RATIO = 3.05 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-HDR H1.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:54:28
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-HDR H1
STATE: OR CODE: IBC
PRODUCT: 3-PLY 1-3/4" X 9-1/2" LP LSL 1.55E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 16.000' 0.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 4973 9855 3889 0.132 0.235
ALLOWABLE 16078 16058 13632 0.274 0.410
STRESS INDICES 0.309 0.614 0.285 L/747 L/419
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
*** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC.
FROM ONE FACE ONLY. STAGGER ROWS. FLIP BEAM AND ATTACH THE THIRD
PLY WITH 2 ROWS OF 16d (3-1/2") NAILS AT 12" OC. TO THE UN-NAILED
SIDE OF THE FIRST TWO PLIES. STAGGER ROWS. NAILS MAY BE COMMON OR BOX
NAILS WITH A MINIMUM SHANK DIAMETER OF 0.131". 16d SINKERS (3-1/4")
MAY BE USED.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
8.500'
TOTAL SPAN: 8.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD ROOF TOP 277.7 PLF 0.000 8.500
+ALL 1 UNIF DEAD FLOOR TOP 120.0 PLF 0.000 8.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 8.500
+ALL 1 UNIF WEIGHT BEAM 15.9 PLF 0.000 8.500
1 1 UNIF LIVE ROOF TOP 416.5 PLF 0.000 8.500
+1 1 UNIF LIVE FLOOR TOP 240.0 PLF 0.000 8.500
Page 2 304-HDR H1.dsn
2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 8.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 8.500
+3 1 UNIF LIVE FLOOR TOP 320.0 PLF 0.000 8.500
4 1 UNIF LIVE ROOF TOP 555.3 PLF 0.000 8.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 9855 3889 1.00
2 4326 1714 0.90
3 7021 2774 1.00
4 9003 3553 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 4973 4973
2 2183 2183
3 3543 3543
4 4543 4543
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 2183 2183
2 2183 2183
3 2183 2183
4 2183 2183
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2790 2790
2 0 0
3 1360 1360
4 2360 2360
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.132 0.274 L/747 0.235 0.410 L/419
2 1 0.000 0.274 0.103 0.410 L/955 0.103 0.155
3 1 0.064 0.274 L/1532 0.167 0.410 L/588
4 1 0.112 0.274 L/883 0.215 0.410 L/459
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.614 0.285
2 0.299 0.140
3 0.437 0.203
4 0.561 0.261
SLENDERNESS RATIO = 1.81 LIMIT = 10.00
Page 3 304-HDR H1.dsn
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-HDR H2.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:55:36
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-HDR H2
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LSL 1.55E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 16.000' 0.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3786 5612 2702 0.071 0.126
ALLOWABLE 10719 10705 9088 0.207 0.310
STRESS INDICES 0.353 0.524 0.297 L/1053 L/593
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
*** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
6.500'
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD ROOF TOP 277.7 PLF 0.000 6.500
+ALL 1 UNIF DEAD FLOOR TOP 120.0 PLF 0.000 6.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500
+ALL 1 UNIF WEIGHT BEAM 10.6 PLF 0.000 6.500
1 1 UNIF LIVE ROOF TOP 416.5 PLF 0.000 6.500
+1 1 UNIF LIVE FLOOR TOP 240.0 PLF 0.000 6.500
Page 2 304-HDR H2.dsn
2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500
+3 1 UNIF LIVE FLOOR TOP 320.0 PLF 0.000 6.500
4 1 UNIF LIVE ROOF TOP 555.3 PLF 0.000 6.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 5612 2702 1.00
2 2449 1184 0.90
3 3991 1924 1.00
4 5124 2468 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 3786 3786
2 1652 1652
3 2692 2692
4 3457 3457
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1652 1652
2 1652 1652
3 1652 1652
4 1652 1652
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 2134 2134
2 0 0
3 1040 1040
4 1805 1805
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.071 0.207 L/1053 0.126 0.310 L/593
2 1 0.000 0.207 0.055 0.310 L/1359 0.055 0.082
3 1 0.035 0.207 L/2159 0.089 0.310 L/834
4 1 0.060 0.207 L/1244 0.115 0.310 L/650
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.524 0.297
2 0.254 0.145
3 0.373 0.212
4 0.479 0.272
SLENDERNESS RATIO = 2.71 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
Page 3 304-HDR H2.dsn
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-HDR H3.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:52:39
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-HDR H3
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LSL 1.55E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 13.000' 8.500' TOP L/360 L/240
SPAN CARRIED IS CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 2136 2634 1416 0.032 0.045
ALLOWABLE 10719 10705 9088 0.174 0.260
STRESS INDICES 0.199 0.246 0.156 L/1937 L/1390
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
*** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT EACH END OF COMPONENT.
STRUCTURAL GEOMETRY
SPAN 1
5.500'
TOTAL SPAN: 5.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING Wl W2 Xl (FT) X2 (FT)
+ALL 1 UNIF DEAD FLOOR TOP 209.0 PLF 0.000 5.500
+ALL 1 UNIF WEIGHT BEAM 10.6 PLF 0.000 5.500
+1 1 UNIF LIVE FLOOR TOP 557.2 PLF 0.000 5.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 5.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
Page 2 304-HDR H3.dsn
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 2634 1416 1.00
2 745 406 0.90
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 2136 2136
2 604 604
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 604 604
2 604 604
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1532 1532
2 0 0
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. L/? INSTANT LONG-TERM
1 1 0.032 0.174 L/1937 0.045 0.260 L/1390
2 1 0.000 0.174 0.013 0.260 L/4916 0.013 0.019
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.246 0.156
2 0.077 0.050
SLENDERNESS RATIO = 2.71 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-HDR H4.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 12:58:04
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-HDR H4
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 9-1/2" LP LSL 1.55E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 0.000' 13.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 3566 5287 2546 0.066 0.118
ALLOWABLE 10719 10705 9088 0.207 0.310
STRESS INDICES 0.333 0.494 0.280 L/1130 L/630
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
*** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" 16d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
6.500'
TOTAL SPAN: 6.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD ROOF TOP 277.7 PLF 0.000 6.500
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 6.500
+ALL 1 UNIF DEAD FLOOR TOP 97.5 PLF 0.000 6.500
+ALL 1 UNIF WEIGHT BEAM 10.6 PLF 0.000 6.500
1 1 UNIF LIVE ROOF TOP 416.5 PLF 0.000 6.500
+1 1 UNIF LIVE FLOOR TOP 195.0 PLF 0.000 6.500
Page 2 304-HDR H4.dsn
2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 6.500
+2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 6.500
+3 1 UNIF LIVE FLOOR TOP 260.0 PLF 0.000 6.500
4 1 UNIF LIVE ROOF TOP 555.3 PLF 0.000 6.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 5287 2546 1.00
2 2340 1132 0.90
3 3593 1733 1.00
4 5016 2416 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 3566 3566
2 1579 1579
3 2424 2424
4 3384 3384
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1579 1579
2 1579 1579
3 1579 1579
4 1579 1579
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 1987 1987
2 0 0
3 845 845
4 1805 1805
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. LI? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.066 0.207 L/1130 0.118 0.310 L/630
2 1 0.000 0.207 0.052 0.310 L/1422 0.052 0.079
3 1 0.028 0.207 L/2658 0.080 0.310 L/927
4 1 0.060 0.207 L/1244 0.112 0.310 L/664
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.494 0.280
2 0.243 0.138
3 0.336 0.191
4 0.469 0.266
SLENDERNESS RATIO = 2.71 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
Page 3 304-HDR H4.dsn
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.
Page 1 C:\Users\NWUD\Desktop\NWUD OFFICE\(STONEBRIDGE HOMES)\PLAN 304\304-BEAMS\304-HDR H5.dsn
LOUISIANA-PACIFIC CORPORATION / WOOD-E DESIGN 2012.2 12/20/13 13:01:33
WARNING
*** THIS DESIGN IS VALID FOR THE PROJECT NAMED BELOW (JOB ID) ONLY
*** WOOD-E DESIGN 2012.2 EXPIRES ON 3/31/2014. LP WILL MAKE AVAILABLE TO
ALL REGISTERED USERS AN UPDATED VERSION OF THE WOOD-E DESIGN SOFTWARE IN
THE CONTINUING EFFORT TO MAINTAIN COMPLIANCE WITH CHANGING BUILDING CODES,
INDUSTRY PRACTICES, CODE EVALUATION REPORTS AND/OR METHODS OF ANALYSIS.
COMPANY: STONE BRIDGE HOMES NW LLC
JOB ID: 304-HDR H5
STATE: OR CODE: IBC
PRODUCT: 2-PLY 1-3/4" X 11-7/8" LP LSL 1.55E
DESIGN CRITERIA FOR FLOOR BEAM (UNFACTORED LOADS)
LIVE DEAD SAFE SPAN (L) SPAN (R) ALLOWABLE DEFLECTION
(PSF) (PSF) LOAD CARRIED CARRIED LOADING LIVE TOTAL
40 15 NO 0.000' 0.000' TOP L/360 L/240
SPAN CARRIED IS NOT CONTINUOUS.
ALLOWABLE / WORKING STRESS DESIGN DATA DEFLECTION
REACTION MOMENT SHEAR LIVE LOAD TOTAL LOAD
ACTUAL 1605 5979 1389 0.117 0.386
ALLOWABLE 10719 16202 11360 0.540 0.810
STRESS INDICES 0.150 0.369 0.122 L/1661 L/503
LOAD CASE 1 1 1 1 1
**** THE REACTION, MOMENT AND SHEAR DATA ABOVE ARE BASED ON THE MAXIMUM
STRESS INDICES AND MAY NOT REFLECT THE ABSOLUTE MAXIMUM ACTUALS.
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
NOTES
CONNECTION
*** DESIGN ASSUMES COMPONENTS CARRIED ARE APPLIED TO TOP EDGE OF BEAM,
SUCH THAT LOAD IS DISTRIBUTED EQUALLY TO EACH PLY.
***ATTACH THE TWO PLIES WITH 2 ROWS OF 16d (3-1/2") NAILS AT
12" OC. STAGGER ROWS. NAILS CAN BE DRIVEN FROM ONE FACE OR
HALF FROM EACH FACE. NAILS MAY BE COMMON OR BOX NAILS
WITH A MINIMUM SHANK DIAMETER OF 0.131" l6d SINKERS (3-1/4")
MAY BE USED, BUT HALF MUST BE DRIVEN FROM EACH FACE.
*** COMPRESSION EDGE BRACING REQUIRED AT 24" O.C. OR LESS.
STRUCTURAL GEOMETRY
SPAN 1
16.500'
TOTAL SPAN: 16.50 FT
LOAD PATTERNS
CASE SPAN SHAPE TYPE SOURCE LOADING W1 W2 X1 (FT) X2 (FT)
ALL 1 UNIF DEAD WALL TOP 100.0 PLF 0.000 11.500
ALL 1 UNIF DEAD ROOF TOP 19.3 PLF 11.500 16.500
ALL 1 UNIF DEAD FLOOR TOP 19.1 PLF 0.000 11.500
ALL 1 UNIF DEAD ROOF TOP 15.0 PLF 0.000 11.500
+ALL 1 UNIF WEIGHT BEAM 13.3 PLF 0.000 16.500
1 1 UNIF LIVE FLOOR TOP 38.2 PLF 0.000 11.500
1 1 UNIF LIVE ROOF TOP 29.0 PLF 11.500 16.500
Page 2 304-HDR H5.dsn
1 1 UNIF LIVE ROOF TOP 22.5 PLF 0.000 11.500
2 1 UNIF LIVE ROOF TOP 0.0 PLF 11.500 16.500
2 1 UNIF LIVE FLOOR TOP 0.0 PLF 0.000 11.500
2 1 UNIF LIVE ROOF TOP 0.0 PLF 0.000 11.500
3 1 UNIF LIVE FLOOR TOP 50.9 PLF 0.000 11.500
4 1 UNIF LIVE ROOF TOP 38.7 PLF 11.500 16.500
4 1 UNIF LIVE ROOF TOP 30.0 PLF 0.000 11.500
+ INDICATES LOAD IS BASED ON SPAN CARRIED AND INPUT LIVE OR DEAD LOAD PSF.
SECTION FORCES CASE MOMENT (LB-FT) SHEAR (LBS) LDF
1 5979 1389 1.00
2 4179 981 0.90
3 5562 1308 1.00
4 5197 1199 1.00
UNFACTORED SUPPORT REACTIONS (LBS) USE THESE VALUES WHEN DESIGNING CONNECTORS
REACTIONS FOR TOTAL LOADS
CASE BRG#1 BRG#2
1 1605 1095
2 1129 729
3 1510 933
4 1383 1013
REACTIONS FOR DEAD LOAD
CASE BRG#1 BRG#2
1 1129 729
2 1129 729
3 1129 729
4 1129 729
REACTIONS FOR LIVE LOAD
CASE BRG#1 BRG#2
1 477 366
2 0 0
3 381 204
4 254 284
MINIMUM BEARING SIZES (IN)
BRG# 1 BRG# 2
3.500 3.500
LIVE LOAD DEFLECTION TOTAL LOAD DEFLECTION DEAD LOAD DEFLECTION
CASE SPAN ACTUAL ALLOW. L/? ACTUAL ALLOW. LI? INSTANT LONG-TERM
1 1 0.117 0.540 L/1661 0.386 0.810 L/503
2 1 0.000 0.540 0.269 0.810 L/723 0.269 0.404
3 1 0.088 0.540 L/2202 0.358 0.810 L/544
4 1 0.068 0.540 L/2863 0.337 0.810 L/577
**** FOR DEAD LOAD DEFLECTION DATA SEE LOAD CASE 2 ****
**** TOTAL LOAD DEFLECTION SHOWN IS INSTANTANEOUS. ****
**** ALLOWABLE DEFLECTIONS ARE BASED ON THE DESIGN SPAN LENGTH (L) OR
TWICE THE LENGTH FOR CANTILEVERS (2L) .
STRESS INDICES CASE MSI VSI
1 0.369 0.122
2 0.287 0.096
3 0.343 0.115
4 0.321 0.106
1
Page 3 304-HDR H5.dsn
SLENDERNESS RATIO = 3.39 LIMIT = 10.00
VERIFY YOUR INPUT TO AVOID DESIGN AND FABRICATION MISTAKES. YOU ARE SOLELY
RESPONSIBLE FOR ERRORS RESULTING FROM INCORRECT INPUT. THIS PROGRAM IS A DESIGN
TOOL AND SHOULD BE USED WITH EXTREME CARE THAT INPUT UNIFORM AND CONCENTRATED
LOADS ARE ACCURATE IN MAGNITUDE AND LOCATION. IF YOU HAVE ANY QUESTIONS OR
UNCERTAINTIES, PLEASE CONTACT LP.
THIS COMPONENT DESIGN IS SPECIFICALLY FOR LP ENGINEERED WOOD PRODUCTS.
USE OF THIS PROGRAM TO DESIGN ANYTHING OTHER THAN LP LVL, LP LSL, OR LPI-JOISTS
IS STRICTLY PROHIBITED. LP IS A TRADEMARK OF LOUISIANA-PACIFIC CORPORATION.