Loading...
Report 1 City of Tigard -.- �2�� Building Division • 13125 SW Hall Blvd, Tigard, OR 97223 AEr'72',, f 7D Phone: 503.718.2439 Fax: 503.598.1960L. T I GARD Inspection Line: 503.639.4175 www.tigard-or.gov 2010 Oregon Solar Installation Specialty Code � Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 15298 SW Greenridge PI City: Tigard Zip: 97224 Owner's Name: Kelly and Jackie Haggerty Date: 7/1/2014 Contractor's Name: Energy Unlimited LLC CCB #: 185705 Design Parameters of the Property/Structure Is the installation If"Yes", does not Flood Hazard ❑ Yes qualify for the Located in a flood prescriptive path, follow Area plain/flood way? ►� No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure � Yes If"Yes", qualifies for "C" or less? 0 No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for above ❑ Yes the prescriptive path. ❑ No 1 I:Building/Forms/PhotoVoltaic-Checklist.docx Is the construction Type of wood and does ® Yes material Construction the construction qualify If"Yes", qualifies for ❑ No the prescriptive path. as"conventional light frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. ® Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight of the PV modules and ® Yes racking less than or If"Yes", qualifies for Solar equal to 4.5 psf? NO the prescriptive path. installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for E1the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Rooftn Single layer If roofing material is g Check the type of ❑ of wood material roofing material shingle/shake one of the three types checked, qualifies for the prescriptive path. Max. two layers ® of composition shingle. Connections of Is the roof mounted solar assembly l>3] Yes the solar assembly connected to roof If"Yes", qualifies for to the roof framing or blocking ❑ No the prescriptive path. directly? 2 I:Building/Forms/Photo Voltaic-Checklist docx Is the gauge 26 or less? ❑ Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. Attachment of ❑ No roof mounted Minimum 24 inches solar systems Spacing of clamps? If the spacing falls directly to inches within 24 inches and 60 standing seam Maximum 60 inches inches, qualifies for the prescriptive path. metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of fastener? ❑ Yes If"Yes", qualifies for the prescriptive path. ❑ No Is the roof decking of WSP min. ''/z"thickness, ❑ Yes decking connected to framing members If"Yes", qualifies for ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the solar modules module to the roof ® Yes If"Yes", qualifies for surface. the prescriptive path. ❑ No 3 I:Building/Forms/Photo Voltaic-Checklist.docx • • Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, iro.ert lines, and, as a. .licable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and s.acini and PV module s stem rackin• attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: SolarWorid Model Number: SW273 Listing Agency: UL q I:Building/Forms/photovoltaic-Checklist.docx