Report RECEIVED
OCT 31 2013
Evaluation Servic CITYOFTIGARD ANS/
A Division of Architectural Testing — Certification Services �L®ING �SIO
Code Compliance Research Report CCRR-0112
Subject to Renewal: 05/08/2014
Visit www.ati-es.com for current status Issued: g
Paagee 1 o0 1 of 2 211
Fiber Composites, LLC 2.2. Properties:
181 Random Drive
New London, North Carolina 28127 Structural Performance
(704)463-2921
www.fiberondecking.com Durability
1.0 Subject Surface Burning
HDPE Guardrail Systems: Decay Resistance
fiberon®Professional Washington Termite Resistance
Certain Teed EverNew 20 3.0 Description
Home Depot Veranda 3.1. General — The Fiber Composites, LLC
2X4 guardrail systems identified in Section 1.0 are
Portico TM guards under the definitions of the referenced
codes. They are intended for use at or near the
PVC Composite Guardrail Systems: open sides of elevated walking areas of
fiberon®Fiberail buildings and walkways, including stairs and
® ramps as described further herein, as required
fiberori®Horizon Mission by the referenced codes.
fiberon®Horizon Provincial 3.2. Guard systems include top and bottom
rails, vertical balusters, posts, rail-to-post
fiberon®Horizon Regency brackets, post mounting brackets, crush blocks,
Home Depot Veranda White Rail decorative moldings, and post caps.
fiberon®Horizon Plus 3.2.1. Level guards with heights of 36 inches
Certain Teed Spectrum and/or 42 inches above the floor surface are
WeatherBest White Rail provided in lengths up to 8 feet (96 inches). See
Severe Weather Deluxe Table 1 and Table 2.
Severe Weather Flat 3.2.2. Stair guards are provided in lengths up to
8 feet(96 inches). See Table 1 and Table 2.
2.0 Research Scope
4.0 Materials and Processes
2.1. Building Codes:
Two different material classifications and
2012 International Building Code(IBC) processes are utilized and identified as HDPE
2012 International Residential Code(IRC) systems and PVC Composite systems.
4.1. HDPE (high density polyethylene) systems
2009 International Building Code(IBC)
consist of rails, balusters, and post sleeves
2009 International Residential Code(IRC) manufactured from an extruded wood-plastic
composite material that is part polyethylene /
Products and Recognized Codes are
summarized in Table 1 and Table 2. polypropylene and part wood fiber.
4.1.1. HDPE Guardrail Systems include
fiberon® Professional Washington, Certain Teed
EverNew 20, Home Depot Veranda, 2X4, and
Portico TM
4.1.2. HDPE guardrail systems are produced in
Gray, Redwood, Brown, Golden Cedar, Cedar,
Tropics Jatoba, and Tropics Mahogany colors.
Architectural Testing 130 Deny Court• York, PA 17406
•••^••^-^�+^�*^^�- 717-764-7700
A
t
A
7'16 _ ATI-ES
Code Compliance Research Report CCRR-0112
Page 2 of 21
4.1.3. Rails and balusters are manufactured 5.1.4. Non-structural 4 inch square HDPE post
from extruded HDPE rectangular stock and then sleeves are available for installation over a
cut and milled to finished shapes. HDPE post conventional 4x4 wood post.
sleeves and 2X4 rails in a Tropics color are 5.1.5.The fiberon® Professional Washington,
extruded directly in the finished profile.
CertainTeed EverNew 20, Home Depot
4.1.4. Balusters are also available in 0.75 inch Veranda, and Portico level top rail assemblies
round, powder coated, galvanized steel with a and the level bottom rails are attached to
0.05 inch thick wall. sleeved 4x4 wood posts using an "L" shaped
4.2. PVC (Poly Vinyl Chloride) Composite steel bracket at each of the four rail-to-post
systems consist of rails, balusters, and structural connection points. See Table 5 for bracket
posts or post sleeves manufactured from an fastening and Figure 6 and Figure 7 for bracket
extruded wood-plastic composite material that is details.
part PVC and part wood fiber with a PVC 5.1.6.The fiberon® Professional Washington,
capstock applied by a co-extrusion process. CertainTeed EverNew 20, Home Depot
Some balusters and post sleeves utilized in the Veranda, and Portico stair top rail assemblies
PVC Composite systems are extruded PVC. and the stair bottom rails are attached to
PVC spindles are injection molded. sleeved 4x4 wood posts with a hinged bracket at
4.2.1. PVC Composite Guardrail Systems each of the four rail-to-post connection points.
include the fiberon® Fiberail, fiberon® Horizon See Table 5 for bracket fastening and Figure 6
series (Mission, Provincial, Regency, Home and Figure 7 for bracket details.
Depot Veranda White Rail, Plus, CertainTeed 5.1.7. 2X4 level top and bottom rails are
Spectrum, and WeatherBest White Rail), and attached to sleeved 4x4 wood posts with nylon
the Severe Weather - series (Deluxe and Flat) brackets. See Table 5 for bracket fastening and
systems. Figure 6 for bracket details.
4.2.2. PVC Composite guardrail systems are 5.1.8. 2X4 stair top rail and the stair bottom rail
produced in White, Almond, Brick, Bronze, are attached to sleeved 4x4 wood posts with a
Slate, Sand, and Black colors. 1-1/4 inch square, solid extruded HDPE baluster
5.0 Assembly cut to the height of the rail and attached to the
post. The rails are then attached to the 1-1/4
5.1. HDPE Guardrail Systems: fiberon® inch square, solid extruded HDPE picket. See
Professional Washington, Certain Teed EverNew Table 5 for connection details.
20, Home Depot Veranda, 2X4, and Portico TM 5.1.9. HDPE guardrail systems have three
5.1.1. fiberon® Professional Washington, baluster options:
Certain Teed EverNewTM 20, Home Depot 1. 1-1/4 inch square extruded HDPE picket;
Veranda, and Portico guard assemblies
consist of a two-part top rail (upper sub-rail and 2. 1-1/2 inch square extruded HDPE picket;
top rail), a single bottom rail, and balusters that 3. 0.75 inch round, powder-coated,
are mechanically fastened to the top and bottom galvanized steel picket.
rails. See Table 3 for baluster fastening details.
5.1.2. 2X4 guard assemblies consist of a See Table 3 for additional baluster information
two-part top rail (top rail and top rail cap), a and Figure 4 for details.
single bottom rail, and balusters that are 5.1.10.A non-structural decorative HDPE post
mechanically fastened to the top and bottom cap and HDPE cove molding can be attached at
rails. See Table 3 for baluster fastening details. the top of the HDPE-sleeved 4x4 wood post and
5.1.3. Railing systems include a bottom rail around its base, respectively.
intermediate support ("crush block") located
beneath the bottom rail every 32 inches or less.
Crush blocks are short pieces of HDPE baluster
fastened to the bottom rail.
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
r
f I
A
ATI-ES
Code Compliance Research Report CCRR-0112
Page 21
5.2. PVC Composite Guardrail Systems: 5.2.4.3. "Standard Mount" brackets3 of are
the fiberone Fiberail, fiberone Horizon series manufactured from 14 gauge galvanized steel
(Mission, Provincial, Regency, Home Depot and are limited to use with 36 inch height railing
Veranda White Rail, Plus, Certain Teed systems.
Spectrum, and WeatherBest White Rail), and
5.2.4.4. "Pro Mount"brackets are manufactured
the 5evereWeather - series (Deluxe and Flat)
systems. from 11 gauge galvanized steel and may be
used with railing system heights up to 42 inches.
5.2.1. The top rail in each of the PVC
5.2.5. Level railing systems include a bottom
Composite systems consists of a single co-
extruded PVC/wood composite with PVC rail intermediate support ("crush block") located
beneath the rail at mid-span. The crush block is
capstock section. All top rails have pre-routed
a 3 inch long section of PVC Composite Flat rail,
holes for installation of balusters or pre-cut
slotted holes for installation of baluster dagger PVC Composite square picket, or PVC picket.
inserts. See Table 3 for additional details. The crush block is secured to the bottom rail
with water-resistant PVC adhesive.
5.2.2. The bottom rail in each of the PVC
Composite systems consists of a single 6.0 Performance Characteristics
co-extruded PVC/wood composite with PVC 6.1. The guard systems described in this report
capstock section. Bottom rails have either have demonstrated the capacity to resist the
pre-routed for baluster installation or pre-cut design loadings specified in Chapter 16 of the
slotted holes for installation of baluster dagger IBC and Section R301 of the IRC when tested in
inserts. See Table 3 for additional details. accordance with ICC-ES AC174 and
5.2.3. PVC Composite guardrail systems have ASTM D 7032.
four baluster options: 6.2. Structural performance has been
1. 1-1/4 inch square co-extruded PVC/wood demonstrated for a temperature range from
composite picket with PVC capstock; -20°F to 125°F.
6.3. Materials used are deemed equivalent to
2. 1-1/4 inch square extruded PVC picket;
preservative treated or naturally durable wood
3. 1-1/4 inch injection molded PVC Colonial for resistance to weathering effects, decay, and
spindles; attack from termites.
4. 0.75 inch round, powder-coated, 6.4. The referenced criteria, AC174, requires a
galvanized steel picket. flame spread index (FSI) not exceeding 200
See Table 3 for additional baluster information when testing in accordance with ASTM E 84.
and Figure 4 for details. Materials utilized in guardrail systems described
5.2.4. Supportsherein have a flame spread index as follows:
— PVC Composite guardrail The HDPE material has an FSI of 115
systems can be attached to sleeved
conventional 4x4 wood posts or to a structural The PVC/wood composite material with
PVC Composite post with railing system co-extruded PVC capstock has an FSI of 35.
allowable heights in accordance with Table 4.
5.2.4.1. Non-structural PVC post sleeves or The PVC material has an FSI of 45.
non-structural PVC Composite post sleeves can 7.0 Installation
be utilized as a cladding over conventional 4x4
wood posts. Installation shall be in accordance with the
manufacturer's installation instructions and this
5.2.4.2. Structural PVC® Composite posts are report. Where differences occur between this
supported by a fiberon Post Mount system for report and the manufacturer's installation
surface mount installations or can be installed in instructions,this report shall govern.
a wood deck with steel joist-mount brackets
("Standard Mount"or"Pro Mount"). 7.1. Assembly of railing systems (rails and
balusters)shall be in accordance with Table 3.
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
, ,
A
�"T►, ATI-ES
Code Compliance Research Report CCRR-0112
7.2. Attachment of railin s stems to su Page 4 of 21
9 Y pports 8.0 Supporting Evidence
shall be in accordance with Table 5 using
connector brackets shown in Figure 6, Figure 7, 8.1. Drawings and installation instructions
Figure 8, and Figure 9. submitted by the manufacturer.
8.2. The reports of testing and engineering
7.3. Railing systems may be attached to
conventional 4x4 wood posts or other suitable analysis demonstrating compliance with the
wood support structure. Wood in the supporting performance requirements of ICC-ES AC174,
structure shall have a specific gravity of 0.50 or Acceptance Criteria for Deck Board Span
greater (Southern Yellow Pine or better) and a Ratings and Guardrail Systems (Guards and
minimum thickness to allow full penetration of Handrails),approved January 2012.
the bracket mounting screws. Conventional 4x4 8.3. Reports of testing and engineering analysis
wood posts or other wood supports are not demonstrating compliance with the performance
within the scope of this report. requirements of ASTM D 7032-08, Standard
7.4. The fiberon® Post Mount may be mounted Specification for Establishing Performance
Ratings for Wood-Plastic Composite Deck
to a wood deck in accordance with the
manufacturer's installation instructions and Boards and Guardrail Systems (Guards or
Figures 23. Handrails).
7.5. The fiberon®Post Mount may be mounted 8.4.A quality control manual in accordance
to concrete and/or steel with approved anchors. with ICC-ES AC10, Acceptance Criteria for
Post mount anchors used in concrete or steel Quality Documentation, approved June 2011.
installation are not within the scope of this report 9.0 Conditions of Use
and are subject to evaluation and approval by
the building official. Anchors must satisfy the The guard assemblies identified in this report
design load requirements specified in Chapter are deemed to comply with the intent of the
16 of the building code and must meet the provisions of the referenced building codes
following minimum requirements: subject to the following conditions:
9.1. HDPE guards are limited to exterior use in
7.5.1.A minimum of four anchor bolts must be
used and located in the four pre-drilled holes in all use groups of the IBC and IRC. See Table 1.
the post base plate. 9.2. PVC Composite guards are limited to
exterior use in the IRC (One- and Two-Family
7.5.2. The anchors must be stainless steel,
galvanized steel, or other approved material Dwellings) and residential use groups R3 and
compatible with the steel post mount system. R4 of the IBC. See Table 2.
7.5.3. The anchors must have a minimum 9.3. Conventional 4x4 wood posts and
diameter equal to 5/16 inch. conventional wood supporting structure for
official, guards are not within the scope of this report
7.5.4.Where required by the building and are subject to evaluation and approval by
engineering calculations and details shall be the building official. Supports must satisfy the
provided. The calculations shall verify that the design load requirements specified in Chapter
anchorage complies with the building code for 16 of the IBC and must provide suitable material
the type and condition of the supporting for anchorage of the rail brackets. Where
construction. required by the building official, engineering
7.6. Steel joist-mount post brackets are bolted calculations and details shall be provided.
to structural wood members (joists or headers) 9.4. Compatibility of fasteners, post mount
with four 3/8 inch diameter bolts. The supporting brackets, and other metallic components with
structure (wood framing) is not within the scope the supporting structure, including chemically
of this report. treated wood, is not within the scope of this
7.7. Post caps shall be installed over the report.
exposed ends of structural PVC Composite 9.5. The use of the referenced guard systems
posts and sleeved conventional 4x4 wood posts. in handrail applications is outside the scope of
7.8. Crush blocks shall be installed between the this report.
deck surface and the guardrail.
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
A
ATI-ES
Code Compliance Research Report CCRR-0112
5 of 21
9.6. Only components and configurations 10.3. The statement "ASTM D 70 2 cPaplant
identified in this report have been evaluated for See CCRR-0112 at www.ati-es.com for uses
performance and/or compliance to the and performance levels".
referenced codes. Labeling of non-identified
components or configurations with the CCRR When applicable, the phrase "For Use in One-
program mark or number is prohibited. and Two-Family Dwellings Only";
9.7. Fiber Composites, LLC guardrail systems 10.4.Architectural Testing Code Compliance
are manufactured in New London, North Research Report number(CCRR-0112).
Carolina in accordance with the manufacturer's 11.0 Code Compliance Research Report Use
approved quality control system with inspections
by PFS Corporation(IAS AA-652). 11.1.Approval of building products and/or
materials can only be granted by a building
10.0 Identification official having legal authority in the specific
jurisdiction where approval is sought.
The guard systems produced by Fiber
Composites, LLC identified in this report shall be 11.2. Code Compliance Research Reports shall
identified with labeling on the individual not be used in any manner that implies an
components or the packaging and include the endorsement of the product by Architectural
following: Testing.
10.1. Name and/or trademark of the 11.3. Reference to the Architectural Testing
manufacturer. internet web site address at www.ati-es.com is
recommended to ascertain the current version
10.2. Identifying mark of the independent
inspection agency, PFS Corporation (IAS and status of this report.
AA-652)
Table 1 —HDPE Railing Systems—Size and Code Recognition
Code Recognition
HDPE Railing System
IBC IRC
8'by 42"Level 8'by 42"Level
8 ft Stair
fiberon®Professional Washington 8'by 38"Level
Certain Teed EverNew 20 N.A. 88"by 30"Stair
Home Depot Veranda
with 0.75 inch with 0.75 inch round,
round, powder powder coated,
coated, galvanized galvanized steel
steel balusters balusters
2X4 8'by 42"Level 8'by 42"Level
8 ft Stair
Portico N.A.
8'by 36"Level
8 ft Stair
1 Railing lengths are the maximum clear length between supports. Railing height is
the installed height from walking surface to top of top rail.
Architectural Testing 130 Deny Court• York, PA 17406 717-764-7700
A
' k. ATI-ES
Code Compliance Research Report CCRR-0112
Page 6 of 21
Table 2—PVC Composite Railing Systems—Size and Code Recognition '
Code Recognition
PVC Composite Railing System
IBC 2 IRC
8'by 42"Level 8'by 36"Level
hberon®Horizon 8 ft Stair 8 ft Stair
Mission, Provincial, Regency, and
Plus 8'by 38"Level
Home Depot Veranda White Rail N.A. 70"by 32"Stair
Certain Teed Spectrum
WeatherBest White Rail with 0.75 inch with 0.75 inch round,
round, powder powder coated,
coated, galvanized galvanized steel
steel balusters balusters
fiberon®Fiberail 6'by 42"Level 6'by 36"Level
Severe Weather Deluxe 6 ft Stair 6 ft Stair
Severe Weather Flat 3
8'by 42"Level 8'by 36"Level
Railing lengths are the maximum clear length between supports. Railing height is
the installed height from walking surface to top of top rail.
2 Code recognition for the IBC is limited to Residential use groups R-3 and R-4
3 The Severe Weather Flat rail style is not provided in a stair rail configuration.
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
A
ATI-ES
Code Compliance Research Report CCRR-0112
Table 3—Railing System Descriptions Page 7 of 21
Railing System Rail/Baluster Assembly Balusters
1-1/4 inch square
fiberon®Professional Top sub-rail and bottom rail are attached to HDPE pi corn rs
Washington balusters with a single#10 by 1-3/4 inch beveled comers
Certain Teed EverNew 20 pan-head wood screw in each end. Screws are 0.75 inch round,
inserted through pre-drilled holes in the upper powder coated,
and lower rails and into each end of the baluster. galvanized steel with a
Double top rail members are fastened together 0.05 inch thick wall
Portico'!" with#10 by 1-3/8 inch screws spaced 1-1/4 inch square
approximately 12 inches apart. HDPE picket with
Bottom rail is attached to intermediate support beveled corners
blocks with a single#10 by 1-3/4 inch screw. 1-1/2 inch square
Top rail and bottom rail are attached to 0.75 inch HDPE picket with
Home Depot Veranda round, powder coated, galvanized steel balusters beveled corners
using two EZ-Mount fasteners (top and bottom) 0.75 inch round,
with one#10 by 2 inch flat-head screw each, powder coated,
galvanized steel with a
0.05 inch thick wall
Top rail and bottom rail are attached to balusters
using two EZ-Mount fasteners(top and bottom)
with one#10 by 2 inch flat-head screw each.
Top rail cap is fastened to the top rail with#10 by 0.75 inch round,
2X4 2-1/2 inch deck screws spaced approximately powder coated,
8 inches apart. galvanized steel with a
Bottom rail is attached to intermediate support 0.05 inch thick wall
blocks with a single#10 by 2-1/2 inch deck
screw.
Balusters are inserted into top and/or bottom
fiberon® rails via pre-routed holes in the rail members.
Fiberail -and/or-
fiberon®Horizon Balusters are attached to the topand/or bottom 1-1/4 inch square
PVC/wood composite
Mission rails via molded plastic dagger inserts. Dagger picket
Provincial inserts are fitted into the baluster and then
Regency placed into pre-cut slotted holes in the rail. 1-1/4 inch square
Plus extruded PVC picket
-or-
Home Depot Veranda Top rail and bottom rail are attached to 0.75 inchhed1-1/4 square-
to inch
n ec ion molded
White Rail round, powder coated, galvanized steel balusters
Certain Teed Spectrum using two EZ-Mount fasteners(top and bottom) PVC colonial spindle
WeatherBest White Rail with one#10 by 2 inch flat-head screw each. 0.75 inch round,
-or- powder coated,
SevereWeather galvanized steel with a
Deluxe Top rail and bottom rail are attached to 0.75 inch 0.05 inch thick wall '
Flat round, powder coated, galvanized steel balusters
using two PVC"dagger"connectors (top and
bottom)that are placed through routed openings.
Limited to use in IRC and in residential use groups R3 and R4 of the IBC.
Architectural Testing 130 Derry Court•• Yor , PA 17406
•^•.• k717-764-7700
A
'�"Ti► ATI-ES
Code Compliance Research Report
CCRR-0112
Table 4—Post Mounting Information Page 8 of 21
Guard System Post Mount System Max. Rail
y Post/Post Sleeve
Height
fiberon®Professional
Washington
Certain Teed EverNew 20 Conventional 4x4 wood posts
Home Depot Veranda (Southern Pine or equivalent 4 inch square 42"
HDPE post sleeve
2X4
PorticoTM Conventional 4x4 wood posts
(Southern Pine or equivalent) 4 inch square
HDPE post sleeve 36"
fiberon®
Fibera/I Conventional 4x4 wood posts PVC Post Sleeve-or-
(Southern Pine or equivalent) PVC/WoodPostComposite 36"
fiberon®Horizon Post Sleeve
Mission fiberon®Post Mount mounted to
Provincial
Regency Surface of wood deck
Plus -or- Structural PVC/Wood
Home Depot Veranda
Concrete surface Composite Post 42"
White Rail (See Figure 23)
Certain Teed Spectrum "Standard Mount"—Joist mount Structural PVC/Wood
WeatherBest White Rail post bracket 36"
Composite Post
Severe Weather
Deluxe
Flat "Pro Mount"—Joist mountost
p Structural PVC/Wood
bracket Composite Post 42"
Architectural Testing 130 Deny Court• York, PA 17406
717-764-7700
•
A
ATI-ES
Code Compliance Research Report CCRR-0112
Page 9 of 21
Table 5—Rail Bracket Fastening Schedule'
Rail—Bracket
Combination Bracket to Post Bracket to Rail
Top Rail(Standard Bracket):
Top and Bottom Rail(Standard Bracket): (4)#10 by 1-3/8 inch long screws
(4)#10 by 2 inch long screws Bottom Rail (Standard Bracket):
715 (4)#10 by 3/4 inch long screws
a'
fiberon®
J Top Rail(Alternate Bracket):
Professional Top and Bottom Rail(Alternate Bracket): (3)#10 by 1-3/8 inch long screws
Washington (2)#10 by 2 inch long screws Bottom Rail (Alternate Bracket):
Certain Teed (3)#10 by 3/4 inch long screws
EverNew 20
Home Depot Top Rail (Standard Bracket):
Veranda Top and Bottom Rail(Standard Bracket): (4)#10 by 1-3/8 inch long screws
(4)#10 by 2 inch long screws Bottom Rail (Standard Bracket):
Portico's L
76
(4)#10 by 3/4 inch long screws
u) Top Rail(Alternate Bracket):
Top and Bottom Rail(Alternate Bracket): (3)#12 by 1 inch long screws
(2)#12 by 2 inch long screws Bottom Rail (Alternate Bracket):
(3)#12 by 1 inch long screws
Top Rail:
a� Top and Bottom Rail: Screws attaching Bracket to Post
°; (3)#8 by 3 inch pan-head T-20 wood screws also"toe-nail'through the rail
2X4 during installation
Top and Bottom Rail:
:ElA 1-1/4 inch square baluster is attached to the Top and Bottom Rail:
(2)#10 by 2-1/2 inch deck screws
rn
post using (6)#10 by 2-1/2 inch deck screws
fiberon® Horizon Structural PVC/Wood Composite Posts:
Mission Top Rail: (2)#12 by 3/4 inch long screws
Provincial m Bottom Rail: (2)#10 by 3/4 inch longTop Rail:
Regency screws (3)#12 by 3/4 inch long screws
Plus —' Conventional 4x4 Wood Post(sleeved): Bottom Rail:
Top Rail: (2)#12 by 2 inch long screws (3)#10 by 3/4 inch screws
Home Depot Bottom Rail: (2)#10 by 2 inch long screws
Veranda White
Rail Structural PVC/Wood Composite Posts:
CertainTeed Top and Bottom Rail: (2) #12 by 3/4 inch long
screws
Spectrum co Top and Bottom Rail:
WeatherBest (1) Conventional 4x4 Wood Post(sleeved): (3)#12 by 3/4 inch long screws
White Rail Top and Bottom Rail: (2) #12 by 2 inch long
screws
(continued on next page)
Architectural Testing 130 Derry Court• York, PA 17406
717-764-7700
A
' ATI-ES
Code Compliance Research Report CCRR-0112
Page 10 of 21
Table 5—Rail Bracket Fastening Schedule'
(Continued)
Rail—Bracket Bracket to Post Bracket to Rail
Combination
fiberon® Structural PVC/Wood Composite Posts:
Fiberail Top Rail: (2)#12 by 3/4 inch long screws Top Rail:
Bottom Rail: (2)#10 by 3/4 inch long screws (2)#12 by 1-1/4 inch long screws
SevereWeather a�
Deluxe J Conventional 4x4 Wood Post(sleeved): Bottom Rail:
Flat Top Rail: (2)#12 by 2 inch long screws N/A
Bottom Rail: (2)#10 by 2 inch long screws
Structural PVC/Composite Wood Posts:
fiberon® Top and Bottom Rail: (2) #12 by 3 inch long N/A
Fiberailscrews 2
SevereWeather 1°
cn Conventional 4x4 Wood Post(sleeved):
Deluxe Top and Bottom Rail: (2) #12 by 3 inch long N/A
screws 2
All fasteners and metal brackets are stainless steel.
2 Fiberail and Deluxe stair rail brackets must be field cut according to the slope of the stair for a flush fit to the
supporting surface and must provide at least 1 inch of fastener penetration into wood supports or full
thickness penetration in Structural PVC/Wood Composite Posts.
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
A
Tl-ES
Code Compliance Research Report CCRR-0112
Page 11 of 21
Top Rail
1.25'
Top Sub-Rail
1.25"
3.25'
A
Bottom Rail
1.Q*
Figure 1 —Rail Profiles
fiberon®Professional Washington, Certain Teed EverNew 20, and Home Depot Veranda
3.75
1.25
1.29
1.52
Figure 2—Rail(Top,Sub,and Bottom)Profiles
PorticoTM
Architectural Testing 130 Derry Court• York, PA 17406
•^•^••^-��*������ 717-764-7700
'A A TI-ES
Code Compliance Research Report CCRR-0112
Page 12 of 21
I 33/4" 3,/'
•
I i � r
2 t/< ! Top Rail i ; Top Rail 1 3 th"
/
-1 1 Ye t Ix
j
.L8.____,,,i ,
3 1R"
---
3
lit
2" 00;;Rail I {r : -]
3 "
Rail
- AJC , ,
PLf
-v.
Mission Provincial Regency and
Home Depot Veranda White Rail
(Top Rail: 0.30 inch Wall)
(Bottom Rail: 0.20 inch Wall)
fc 31/4'
1/' 1
f )
I2 ye ITop Rail
IN
- 272-- -
3 !z" i }
i
.. 2.15 I� \1-
20
I / } lam (
( I
5 (,__
_ -
i, _L______,t
w i
r 2.70 -...
Horizon Plus Deluxe and Fiberail Severe Weather Flat
Certain Teed Spectrum TM (Top Rail) (Top and Bottom Rail)
WeatherBest White Rail
1.570
R0.188
I3amm___F.
5.250 0.945
.630 '�
_i_ 14"----
2X4 Top and Bottom Rail 2X4 Top Rail Cap
Figure 3—Rail Profiles
Architectural Testing 130 Deny Court• York, PA 17406
•^•^••�-��+��+��... 717-764-7700
' ATI-ES
Code Compliance Research Report CCRR-0112
Page 13 of 21
32.0
7.0 19.7
PVC Colonial Spindle
32 inch Length Shown(Mission, Provincial, Deluxe,and Flat)
34 inch Length (Regency and Home Depot Veranda White Rail)
25 + 1.25
1.25 1
i
1
1.25 j 1.25
1.25
-0.12
r ` / .
1-1/4 inch Square 1-1/4 inch Square PVC/Wood 1-1/4 inch Square
Extruded PVC Picket Composite Baluster Solid HDPE Baluster
(0.08 inch Wall) (0.125 inch Wall)
+ 1.50 •-
1
- 0.75
1.50 {
0
I - \. . 0.67
1-1/2 inch Square Solid HDPE Baluster 0.75 inch Round Steel Baluster
Figure 4—Baluster Profiles
Architectural Testing 130 Deny Court• York, PA 17406 717-764-7700
•
A
ATI-ES
Code Compliance Research Report CCRR-0112
Page 14 of 21
} 4.350 4.0 {
4.000
3.600
4.350
4.0 4.000
y l
HDPE Post Sleeve PVC/Wood Composite Post Sleeve PVC/Wood Composite Post(Structural)
(0.325 inch Wall) (0.175 inch Wall) (0.30 inch Wall)
Figure 5—Composite Posts and Post Sleeves
:.. 1.62.. J..
603
1.5 �\ � 21
-r
411111a
24
00.2—,/ ryry0
is
*It
l ,
NYiq - !I 117
Standard HDPE Level Bracket Standard HDPE Stair Bracket
a
•
4141
2X4 Level Bracket
Figure 6—Attachment Brackets for HDPE Systems
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
IN
A
' 111, ATI-ES
Code Compliance Research Report CCRR-0112
Page 15 of 21
1.430 R0.185
1.25
wmh6w__ - I
2065
Hill .
80.060--- ; 1.250 f
119%**4114
I
0.9 I,` �L 4441%'...':-:7
1
-. 0.135 i
---
Level Bracket/Top Level Bracket/Bottom Hinged Bracket-Stair
Figure 7—Attachment Brackets for:
PVC Composite Systems: Mission, Provincial, and Regency
HDPE Systems: fiberon°Professional Washington, Certain Teed EverNew 20,
Home Depot Veranda,and Portico"'
/LA1,411
jiligs `1 8111
l
Iti
Deluxe and Fiberail Severe Weather Flat Rail Bottom Rail—Edge
Top Rail PVC Bracket PVC Bracket PVC Bracket
—1.25 � L//7_,,
� /L j
0.13
2.13
0.67 CI
0.13 II=
ninannlini
1- 1.13-71 1.81
Top Rail Stainless Steel L-Clip PVC Dovetail Clip
(Deluxe, Fiberail and Flat Top Rail Brackets) (Deluxe, Fiberail, Flat, and Edge Brackets)
Figure 8—Attachment Brackets for PVC Systems
Deluxe-and Flat Level Rails
Architectural Testing 130 Deny Court• York, PA 17406 717-764-7700
A
• - TiL ATI-ES
Code Compliance Research Report
CCRR-0112
Page 16 of 21
::...„1"
a�
`fiTe-r% `*
„dip" - ,
4
Figure 9—Attachment Brackets for PVC Systems
Deluxe and Fiberai/-Stair Rails
1,10.„,
, _
0.953 liar' 0.943
jl
I
I .
II: -
1'"�•1 ll 0.953 0.993 s'.
.I.�il, A
i ;-
t::,0.032 '-" x'0.207 ;1{
0.379 I 0.250 4i I :
11110,148 I 0.0981 ir-
t
I }��,
1 �}, 'I g tF { 1750
0.320 1, 0.750 ' 1:: .....
f rn !
Ifll
I
I
I' r H-0.124 , ." � I � 3.167
,C 2.500 1 i
_, ,+'I' I' r hiI(
{ i
Ill Mil
I Ill
111
0.296
0.938
0.987 Illi.
Level Rail Dagger Stair Rail Dagger(Angled)
Figure 10—Square Baluster Dagger Inserts
Mission and Provincial Baluster Attachment to Bottom Rail
Architectural Testing 130 Derry Court• York, PA 17406
www.archtest.com 717-764-7700
ATI—ES
Code Compliance Research Report
CCRR-0112
Page 17 of 21
0.669 1.148
Level Rail EZ-Mount Stair Rail EZ-Mount
tsVt
too
�.6425
ow=rim .8750 s
1.imir
9750PPrw !.
.56(X) flhtoa8 II�' .0405 I
�4u iK I Iflllllll
58" . 1Inn
.7450 .2450
.7450
Level Rail Dagger Inserts Stair Rail Dagger Inserts (Angled)
Figure 11 —Round Baluster Daggers
Mission and Provincial Baluster Attachment to Bottom Rail
Architectural Testing 130 Derry Court• York, PA 17406
www.archtest.corn717-764-7700
,
. . .
A
''lik_ A Tl-ES
Code Compliance Research Report CCRR-0112
Page 18 of 21
--PoSI CAP
�..-
"�.^iOSf SLEEP£ TOP 0.3.
rs
S.
BO,TOR,EUB VAL
NifAO-ANGEAptE S XKTANE STAIR 9UC4T
AOkbTablE _. Knit
ST%R i a_ 'TCP OR BOTTOM?
bRACRfT ^
,yr.
} 6
f
1 7
.esti M� ,i
j Rif 8RK[ET
t
�'i &Hl5TE0.
ssTE
4 t'"..
CALMS
.» „A„a 40k6tA&ESiI3R i
t
eau. hT w,�A.
R banao
TA i
1011 I
-
COVE MGEJL DETC
Rm*ae suyuuL
sr,WOOD INSERT MS?COVE KM,...
Figure 12-Portico TM Figure 13-Professional Washington,
Home Depot Veranda, and Certain Teed EverNew 20
/\ ------POST CAP Imo.`--i"P°Si CAR
...114_,. .►moi".
,��. ^!I� NE
'"POST "- �4 POST BRACKET
0
MISSION RAIL ��'`` "OVINCIAL TOP RAIL
A� TOP UNE / ` ,`
AD]UST': iir .'.� 11111
,.... .1 BRACKET • 1" .TT,
STAIR
BRACKET ! ADJLlSTABL
`SQ.BALUSTER STAIR I
�� •.BALUSTER
BRACKET JJ
FINER E
INDLE
COVE
MOULDING
BOTT.
RAIL V
I RAIL
' NE STA
STAIR J�iBALUSTER BALUSTER
BALUSTER \ ItgERT INSERT
1111 / L[tE
INSERT / / `'� 4I., BALUSTER
• ? // e.� I` BLOCK �r/ IeCRUSH
' '`'.''..,,, ^-o,,;; K. BLOCK
COVE MOULD' fl
JOIST
UNE MOUNT
JOIST MOUNT
BRACKET BRACKET
BRACKET •• OM UNE
BRACKET
Figure 14-fiberon®Mission Figure 15-fiberon®Provincial
Architectural Testing 130 Derry Court• York, PA 17406
�•-•-••---��---�----. 717-764-7700
A
'14„.., ATI—ES
Code Compliance Research Report CCRR-0112
Page 19 of 21
Z'c6Tc4r. 44>
fir . k
ADJUSTABLE ,,,R,„,.
STAIR 41 -.��40 _
BRACKET
f
1 � ? ' r ,....-4: 1 = z
�, NE BRACKET
i j
I
g i 6$p v
, S s RINSE
"gi At':1; .,. rt f 1 / t,I
IT ki — ;'-i ' IlAil 7/' 'Pt-44* -k . =4„,,..
SII
y....„ ,, .„ `USN"'I' I% f g"'�
ES000O7NG ��/f '�/ @ ®' �' fit
` fie ! ;x
;.1TC1M LINE BRACXET / g u-
I
O1ST
MOUNT
BRACKET
Figure 17-Deluxe and Fiberail
Figure 16-fiberon®Regency
and Home Depot Veranda White Rail
"�►_ fir'
,�°,Mviai goo
.
f / i
1[ 'i1
ii 1 II
; t
til i� � � I~ I
/� ' All,, „ t iI �
0 0 I /,
•
Figure 18-Severe Weather Flat Figure 19-fiberon®Horizon Plus,
Certain Teed Spectrum,and
WeatherBest White Rail
Architectural Testing 130 Derry Court• York, PA 17406 717-764-7700
I . s
A
' k` A Tl-ES
Code Compliance Research Report CCRR-0112
Page 20 of 21
4/ ;SII
1II 1
11
I
1116
000000
Figure 20—2X4 Figure 21 —2X4 in Board-over-Post Installation
Post
ty.....0 /1. 3,...-'
c
o a o 0
:
Line post bracket Corner post bracket
Figure 22—Joist-Mount Brackets
Standard Mount(14 gage steel)
Pro Mount(11 gage steel)
Architectural Testing 130 Deny Court• York, PA 17406 717-764-7700
6 r
a 1 IF , f
A
-,--11L ATI—ES
Code Compliance Research Report CCRR-0112
Page 21 of 21
Part Sizing— i.,
staaaia�i �tT
:41111111r BMd the ends ar
the sizing
pliers to o'event
5fu.althe puost arum
Compasite sliding ,
Pan
511G"-18 x 5-112'
Wax Colt
Fiher5115'-18 a$?4'Campasitts` Leveling Set Sc ews �I�POStrt 'METAL ROSr
rt1QLrntii +
Base plata; I Aa^ENERS
Pushed --__
Deck
1110
4' 2'Star-las'.c
0. 1.!'-11111111. 1
Steel Fasteners
EVEUUNG SCREWS
�. BASE AA
4 .
10
ii 11;le t CONCRETE •y
00-} i
ei irk.
Ute•deck reinforcement two
2'x Si*(nsit+iriurn)treated lumber snv Fend,Washer CONCRETE APPLICATION
Wood Deck Corner Installation
I. 1
I'x#' 3 Stainless
Reinforcement op Boards Steel fasteners
111- 1 - —1Wfb'1
.10-000: 00P-A-4-
--6-131
Joist if III
? * ter ± '* • `'
5J1K"
Underdedc t ,.v.„.40w
1
* * '
reinforcement PP Joist Jairt
Fender 2^x 8'(minimum)
1111
Washer treated lumber -
Wood Deck Line Installation Wood Deck Support Blocking
Figure 23—fiberon®Post Mount
Architectural Testing 130 Deny Court• York, PA 17406 717-764-7700